Loading...
HomeMy WebLinkAboutPROJECT SUMMARYFlorida Energy E iciency Code For Building Construction Florida epartment of Community Affairs EnergyGaug FLA/COM 2004 v3.00 -- Form 40OA-2004 Method A: Whole Buil ing Performance Method for Commercial Buildings Effective December 8,2006 Short Desc: HANGARS Owner: Enter Owner's name Addressl: ST. LUCIE AIRPOI Address2: Enter Address here Type: Office Jurisdiction: ST LUCIE Cond Area: 2004 SF No of Storeys: I Permit No: 0 1/3/2007 PROJECT SUMMARY Description: HANGERS H & III City: FT. PIERCE State: FLORIDA Zip: 0 Class: New Finished building ST LUCIE COUNTY, FL (66 1000) Cond & UnCond Area: 2004 SF Area entered from Plans 0 SF Max Tonnage 5 If different, write in: EnergyGauge FLA/COM 2004 v3.00 I k Compliance Summary Component Design Criteria Result Gross Energy Use 1,570.4 1,623.1 PASSES LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTI PIPING SYSTEMS Met all required compliance 1/3/2007 Check List? PASSES None Entered PASSES None Entered None Entered None Entered Yes/No/NA !RTANTNOTE: An �nput report of this design building must be submitted with this Compliano Report. EnergyGauge FLA/COM 2004 v3.00 2 CERTIFICATIONS I hereby certify that the plans and s1pecif ions cove y this calculation are in compliance with the Florida Energy Code t�� 7 Prepare By: Building Official: ate: Date: I certify that this building is in co !pli nce with the Fl-orida Energy Efficiency Code Owner Agent: Date: 7 If Required by Florida law, I here Lycertify that the system design is in compliance with the Fl-orida Energy Efficiency Code Architect: Reg No: Electrical Designer: Reg No: ty S— Lighting Designer: Reg No: Mechanical Designer: Reg No: Plumbing Designer: Reg No: (*) Signature is required whelrd Florida"Law requires design to be performed by registered design professionals. Typed names alrid registration numbers may be used where all relevant information is contained on signed/sealed p1hIns. Project: HANGARS Title: HANGERS H & 1111 Type: Office (WEA File: DAYTONABEACILT hole Building Compliance Design Reference Total 96.55 100.00 $1,570 $1,623 ELECTRICITY(Mulk 96.55 100.00 Wh/$) 31097 $1,570 32268 $1,623 AREA LIGHTS 18.00 20.91 5788 6751 $292 $340 MISC EQUIPMT 13.64 13.64 4404 4404 $222 $222 PUMPS & MIS 0.09 0.09 32 32 $2 $2 SPACE COOL 25.64 21.36 8258 6889 $417 $347 VENTFANS 39.18 44.00 12615 14192 $637 $714 Credits & Penalties (if an y.): Modified Points: 96.55 PASSES External Lighting Compliance Description Category Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (Sqft or ft) None 1/3/2007 1 1 EnergyGauge FLA/COM 2004 v3.00 Project: HANGARS Title: HANGERS H & III Type: Office (WEA File: DAYTONABEACH.TM Li�iting Controls Compliance Acronym Ashrae Descri tion 111) Area No. of Design Min Compli- (sq.ft) Tasks CP CP ance PrOZolSpl 17 Office - 'I" closed 2,004 1 4 1 PASSES PASSES Project: HANGARS Title: HANGERS H & III Type: Office (WEA File: DAYTONABEACH.TL System Report Compliance PrOSyl System I Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled � 65000 Btu/h Cooling Cap city Air Handling Air Handler�(Supply) - System -Supply Constant V�lume 13.00 13.00 9.00 PASSES 0.80 0.90 PASSES PASSES Plant Compliance Description Installed Size Design Min No I I Eff Eff Design Min Category Comp 11PLV IEPLV Iiance None 1/3/2007 1 EnergyGauge FLA/COM 2004 v3.00 Water Heater Compliance Description Type Category Design Min Design Max Comp Eff Eff Loss Loss liance F--None Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick[in] Thick[in] [F] SF.FJ None Project: HANGARS Title: HANGERS H & III Type: Office (WEA File: DAYTONABEAC TMY) Other Required Compliance Category Sectio I Requirement (write N/A in box if not applicable) Check Infiltration System Ventilation ADS T&B Motors Lighting O&M Roof/Ceil ort 40611 4071 40 .1 411.1 410.1 4�4-1 415.1 1 1 2.1 04.1 Infiltration Criteria have been met HVAC Load sizing has been performed Ventilation criteria have been met Duct sizing and Design have been performed Testing and Balancing will be performed Motor efficiency criteria have been met Lighting criteria have been met Operation/maintenance manual will be provided to owner R-19 for Roof Deck with supply plenums beneath it Input Report Print -Out from EnergyGauge FlaCorn attached? El El 1/3/2007 1 EnergyGauge FLAICOM 2004 v3.00 EnergyGauge FLAXOM 2004 v3.00 I INPUT DATA REPORT I Project Name: HANGARS Project Title: HANGERS Il & III Address: ST. LUCIE AIRPORT Enter Address here State: FLORIDA Zip: 0 Owner: Enter Owner's natne here Proiect Information, Orientation: North Building Type: Office Building Classification: New Finished building No.of Storeys: 1 GrossArea: 2004 SF No Acronym Description Type Area 1sq Multiplier Total Area Isn 1 PrOZo I Zone I CONDITIONED 2004.0 1 2004.0 Spaces No Acronym Description Type Depth Ift] Width Height Multi Ift] [ft] plier TotalArea 1sq Total Volume [cf] 9 . % 1/3/2007 EnergyGauge FLAXOM 2004 v3.00 In ZZone PrOZol 1 Pr0ZolSv1 ZoOSpl Office - Enclosed 30.00 66.80 12.80 1 2004.0 25651.2 El Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts In Zone: PrOZol In Space: Pr0Zo1Sp1 1 Suspended Fluorescent General Lighting 15 126 1890 Manuid On/Off 4 Walls No Description Type Width H (Effee) Multi Area DirectionConductance Heat Dens. R-Value [it] Ift] plier [sfl [Btu/hr. sf. F] Capacity [lb/cil [h.sEF/Btu] [Btu/sEF] In Zone: PrOZol I PrOZolWal Mtl Bldg Roof/R- 11 66.80 12.80 1 855.0 South 0.0967 0.867 9.57 10.3 0 2 PrOZolWa2 Batt Mtl Bldg Roof/R- 11 30.00 12.80 1 384.0. West 0.0967 0.867 9.57 10.3 El ---3--MZ a3 oiw� Batt Mtl Bldg Roof/R-1 1 30.00 �-a 12.80 1 384.0 East 0.0967 0.867 9.57 10.3 4 Pr0ZolWa4 Partition WwaU, 0�-66;80_12.80 1 855.0 No 0.83 in. gyp, airspace, 0.75 in. gyp Windows No Description Type Shaded U SHGC Vis.Tra W H (Effee) Multi Total Area [Btu/hr sf F) [ftj [ft] plier Isf] In Zone: PrOZol In Wall: PrOZolWal 1 PrOZolWalWil User Defined No 1.2500 0.70 0.58 3.00 4.00 4 48.0 2 PrOZolWalWi2 UserDefined No 1.2500 0,70 0.58 3.00 8.00 2 48.0 El 1/3/2007 EnergyGauge FLAXOM 2004 v3.00 Doors f4 A none Hant Von R-Value No Description Type Shaded? width nkmlice) iviLuld Area v" . Ift] [ft] plier [sQ [Btu/hr. sf. F] Ilb/cfl [Btu/sE F1 [h.sf F/Btuj Zone: PrOZol In Wall: PrOZo1Wa4 24.0 0.1919 43.67 0.53 5.21 I PrOZolWa4Drl Aluminum door, No 3.00 8.00 1 1.25 in. Roofs No Description Type Width H(Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value Vtl [ft] 'plier [sq [deg] [Btu/hr. St F] [Btu/sE F] Ilb/CQ [h.sEF/Btuj Zone: PrOZol 1 PrOZolRfl Mtl Bldg Roof/R-19 30.00 66.80 1 2004.0 0.00 0.0492 1.34 9.49 20.3 Batt S41ights No Description Type U SHGC Vis.Trans W H(Effec) Multiplier Area TotalArea [Btu/hr sf F1 [ft] Ift] Isf] [Sf] In Zone: In Roof. No Description Type In Zone: PrOZol 1/3/2007 Floors Width H(Effec) Mufti Area Cond. Heat Cap. Dens. R-Value [ft] [ft] plier [sq [Btu/hr. sE F] [Btu/st F1 [lb/cq NsEF/Btul EnergyGauge FLA/COM 2004 v3.00 IN-1 3 1 Pr0ZolFlI 1 ft. soil, concrete 30.00 floor, carpet and rubber pad 66.80 1 2004.0 0.1745 54.OU IMMU 3.11 Syst ems Prosyl System I Constant Volume Air Cooled Split No. Of Units I System < 65000 Btu/hr Component Category 1 Cooling System (Air Cooled < 65000 Btu/h Cooling Capacity) 2 Air Handling System -Supply (Air Handler (Supply) - Constant Volume) Capacity - Efficiency I1PLV 60000.00 13.00 9.00 1800.00 0.80 Plant Equipment Category EE= size Inst.No Eff. EPLV LLLJJJ :Ir Water Heaters 1==e ate =r-DNes c ription Capacit3Cap.Unit IYP Rt. Efficiency Loss 13 Ext-Lighting Description Category No. of Watts per Area/Len/No. of units Control Type Wattage Luminaires Luminaire [sVfVNol [w] 1/3/2007 EnergyGauge FLAXOM 2004 V3.00 Piping_ Operating Insulation Nomonal pipe Insulation Is Runout? No Type Temperature Conductivity Diameter Thickness [F] Btu-in/lLsEF] [in] [in] El Fenestration Used MEMNON Name Glass Type No. of Glass SHGC VLT Conductance Panes [Btu/b.sEF] ASHULTntAllFr I Tser Defined 1 1.2500 0.7000 0.5800 m Materials Used Only R-Value RValue Thickness Conductivity Density SpecificHeat dat-No-A Description Used [b.stF/Btul [ftj [Btu/h.ft.FJ [lb/cfl [Btu/Ib.Fl 264 Matl264 ALLTMINUM, 1/16 IN No---0.0002 0.0050 26.0000 480.00 0.1000 214 MatI214 POLYSTYRENE,EXP., No 5.2100 0. f(YC---0.0200 1.80 0.2900 E3 MAIN, 178 MatI178 CARPET W/RUBBER PAD Yes 1.2300 265 Matl265 Soil, I ft No 2.0000 1.0000 0.5000 100.00 0.2000 48 Matl48 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 57 Mad57 3/4 in. Plaster or gypsum No 0.1488 0.0625 0.4200 100.00 0.!000 72 MatI72 AIR LAYER, 3/4IN OR Yes 0.9000 12 MatI12 LESS, VERT. WALLS 3 in. Insulation No 10.0000 0.2500 0.0M 2.00 0.2000 0' 23 Matl23 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 1/3/2007 EnergyGauge FLA/COM 2004 v3-00 94 Mat194 BUILT-UP ROOFING, No 0.3366 0.0313 0.0930 70.00 0.3500 3/81N Constructs Used Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sLFj [Btu/sEF] [lb/cf] 1h.sEF/Btul 1002 Aluminum door, 1.25 in. polystyrene No No 0.19 0.53 43.67 5.2 Layer Material Material No. 1 264 ALUMINUM, 1116 IN 2 214 POLYSTYRENE, EXP., 1-1/4IN, 3 264 ALUMINUM, 1/16 IN Thickness Framing [ft] Factor 0.0050 0.000 1:3 0.1042 0.000 0.0050 0.000 Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/b.sf.Fl [Btu/sf.Fl [lb/cfl [h.sf.F/Btul 1005 1 ft. soil, concrete floor, carpet and rubber pad No No 0.17 54.00 108.00 5.7 Layer Material Material NO. 265 Soil, I ft 2 48 ­76-ft.-HeaVyweigh-1 C—Oncrete 3 179 CARPET W/RUBBER PAD Thickness Framing [ft] Factor 2.0000 0.000 0.5000 0.000 0.000 IN 1/3/2007 EnergyGauge FLA/COM 2004 v3.00 6 9 Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/b.sf.F] [Btu/sEF] [lb/cfl [bsEF/Btul 1008 Partition wall, 0.75 in. gyp, airspace, 0.75 in. No No 0.83 2.50 100.00 1.2 Layer Material Material Thickness Framing No. Ift] Factor 1 57 3/4 in. Plaster or gypsum 0.0625 0.000 2 72 AIR LAYER, 3/41N OR LESS, VERT. 0.000 WALLS 3 57 3/4 in. Plaster or gypsum 0.0625 0.000 Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.Fl [Btu/sEFJ [lb/cfl [b.sEF/Btul 1046 Mtl Bldg Roof/R-11 Batt No No 0.10 0.87 9.57 10.3 Layer Material Material No. 94 BUILT-UP ROOFING, 3/81N 2 12 3 in. Insulation Thickness Framing [it] Factor 0.0313 0.000 0.2500 0.000 Simple Massless Construct Construct Conductance Heat Capacity 1047 Mtl Bldg Roof/R-19 Batt No --No 0.05 1.34 Layer Material Material Thickness Framing No. [ft! Factor 1 94 BUILT-UP ROOFING, 3/8IN 0.0313 0.000 2 23 6 -in. Insulation 0.5000 0.000 1/3/2007 EnergyGauge FLAXOM 2004 V3.00 Density RValue [lb/cfl [h.sf.F/Btul 9.49 20.3 7