Loading...
HomeMy WebLinkAboutPROJECT SUMMARY (2)M I ar 14 07 09:18a Major Canvas Awnings, Inc 772-336-9501 p.3 Jaw BOYLE STVL 07593 P. 03/09 John Boyle and compapy pace a Gfii .34arrb 2, 1999 ON ABSTRACT Patio 5W style 5W ut 0* 0714 Test Standard: AS= E X 81-M Standard Test Method for EWWACE Md CHARACTMancS O-PBUJIDING (ANSI 24 N"A 255, UBC 8.1, yjL M) Test Date: lfebru=7 25, 1998 Test Spanwr: �r 0hu BoYle and Company Testpasults: FLA= SPRF AD RqDEX EMEE IDEVFA�OpM IND= 'fte dBsm� V-tim, the'lest Plucedam and specimm!��tO4 as wen as the obierva" "a reffidts ebtafiie4 canUdned herei. ae and awu=te wiain the Hmits O:f sound 4=0"'.Ing true PracUce� These 01flyfor the Rbscilmn(s) tesftd and mWiLot zvresmt of Othei 2pocismens froin the ssm or otber producenix lots, OineVaPaint nrntarieri,, br- autbariz" the client repr64fuce rato �- nanted herein to, The test this rOPM* GMJYif reyvaducedin its enar"Y' - ldezitMcatj�m is as provided by the Z;;Wand Omega Point Luboratndg -mepU y UmccWmaies exerehL Dau-%, Hg!xyh 2,1998 Scale Tpgrfil3g W :i� R. I Daft: US L& �U* P-E. No. 65296 Execulive'01ce Preside= argdq uuor- e44.:nT .6n IT OR-1 Florida Energy Effibiency Code For Building Construction Florida Department of Community Affairs EnergyGauge�� LA/COM 2004 v3.00 -- Form 40OA-2004 Method A: Whole Building Performance Method for Commercial Buildings Effective December 8, 2006 PROJECT SUMMARY Short Desc: HANGARS Owner: Enter Owner's Addressl: ST. LUCIE k Address2: Enter Address Type: Office Jurisdiction: ST LUCIE C( Cond Area: 2004 SF No of Storeys: I Permit No: 0 Description: HANGERS 11 & III lere T City: FT. PIERCE State: FLORIDA Zip: 0 Class: New Finished building ST LUCIE COUNTY, FL (661000) Cond & UnCond Area: 2004 SF Area entered from Plans 0 SF Max Tonnage 5 If different, write in: 1/3/2007 EnergyGauge FLA/COM 2004 v3.00 Right -Suite Ahl JOHN FOSTEI For: HANGARS WW IV & V FT. PIERCE, FL Htg CIg Outside db (OF) 42 90 Outside RH (%) - 59 lutside wb (OF) - 78 'I ,range ITIM, (OF) - 15 'i ture diff. (gr/lb) - 61 Heating Equipment Make 1 Model 2TEC Type ELE mmercial Short Form Efficiency / HSPF 1000 Heating Input 34060 MBtuh Heating Output 0.0 MBtuh Humidifier 0.0 gpd Leaving Air Temp 70.0 OF Actual Heating Fan 0 cfm Equipment Location Syste! n�' Type Fan Motor Heat Type Fan &jMotor Combined Efficiency StaticiPressure Across Fan Job: JUL 17, 2006 Htg Clg Inside db (OF) 70 75 Inside RH (%) - 50 Inside wb (OF) - 63 Design TD (OF) 28 15 Cooling Equipment Make TRANE Model 2TTR3060A Type STRAIGHT COOL COP/EER/SEER 13.0 Sensible Cooling 41500 MBtuh Latent Cooling 16500 MBtuh Total Cooling 58000 MBtuh Leaving Air Temp 55.0 OF Actual Cooling Fan 1800 cfm Ahl VAV DRAWTHRU 10.0 % 0.1 in H20 NAME Area ft'. Heat Loss Sensible Gain Latent Gain Htg cfm Cig cfm Time SHOP 810 10465 15153 5907 0 679 Jul 1500 OFFICE 3 180 2659 4120 1199 0 188 Jul 1500 OFFICE 1 144 2166 3365 960 0 154 Jul 1500 OFFICE 2 144 1420 2648' 960 0 117 Jul 1500 ACCM 42 774 619 609 0 20 Jul 1500 ACCW 48 2257 1333 2087 0 27 Jul 1500 OPEN 642 10152 13646 4703 0 615 Jul 1500 Ahl 2010 29894 40885 16424 0 1800 Jul 1500 Right -Suite AM JOHN FOSTEF For: HANGARS WW IV & V FT. PIERCE, FL ommercial Load Summary Zone: Ahl COOLING LOAD 1. DESIGN CONDITIONS at Jul 1500 Peak load at Jul 1500 Inside: 75 OF Outside: 90 OF TD: 15 OF RH: 50 % �Ioisture: 61.5 gr/lb Mult: 1.0 Ins.wb Sensible 2. SOLAR RADIATION THROUGH GLASS 917 3. TRANSMISSION GAI S Sensible 11929 Walls: 2724 - Glass: 406 - Doors: 810 - Partitions: 0 - Floors: 0 - Roofs/Ceilings: 7990 - Return Air Ceiling: 0 - 4. INTERNAL HEAT GAIN Sensible Latent 21784 Occupants: 2746 1982 - Lights: 14452 - Motors: 0 - Appliances: 4586 0 - 5. INFILTRATION: Outside air cfm: 30 495 6. SUBTOTAL: , Space load 35125 7. SUPPLY DUCT 0 8. SUBTOTAL. Bldg comp's and supply duct 35774 Actual cfm: 1800 atSupplyTD: 20 - 9. VENTILATION Make-up air cfm: 310 5110 10. RETURN AIR ZOAD: Lighting & roof (net) 0 11. RETURN DUC[r 0 12. TOTAL LOADS ON EQUIPMENT 40885 HEATING LOAD 13. DESIGN CONDITIONS Mult: 1.0 Inside: 71b OF Outside: 42 OF TD: 28 OF 14. TRANSMISSION LOSSES 10738 Walls: 2697 - Glass: 784 - Doors: 1564 - Partitio 0 - Floors:1 2880 - Roofs/Ceilings: 2814 - Return'Air Roof: 0 - 15. INFILTRXTION: Outside air cfm: 137 4210 16. SUBTO i, L. B ilding components ITIA - U1 14948 17. SUPPL��DUCT: 0 18. A VENTILATION: Make-up air cfm: 310 9539 19. HUMIDIFICATION 5406 20. RETURN DUCT 0 21. TOTAL HEATING LOAD ON EQUIPMENT 29894 vvr-i4ghtSC>ft Rfght!Suite Commercial 5.8.13 RSC50847 ProjectInc Job: JUL 17, 2006 63 OF Latent 1982 1274 3256 13168 16424 2006-Jul-27 18:23:15 Page 1 5 lCompliance Summary Component Design Criteria Result Gross Energy Use 1,570.4 1,623.1 PASSES -,,J,16HTING CONTROLS PASSES EXTERNAL LIGHTING None Entered HVAC SYSTEM PASSES PLANT None Entered WATER HEATING SYSTEM/S None Entered PIPING SYSTEMS None Entered Met all required compliance from Check List? Yes/No/NA IMPORTANTNOTE: An input report of this design building must be submitted jalong with this Compliance Report. 1/3/2007 EnergyGauge FLAJCOM 2004 v3.00 2 CERTIFICATIONS I hereby certify that the pla:ns and s icatio r2b this calculation are in compliance with the '�s Flbfida Energy Code /2c D- -A Building Official: F . / I Date: Date: I certify that this building is in com liance with the FLorida Energy Efficiency Code Owner Agent: 415z�- —(Z-011-- Date: A V If Required by Florida law, I her by certi that the system design is in compliance, with the FLorida Energy Efficiency Code Architect: Reg No: Electrical Designerl Reg No: Lighting Designe�: RegNo: Mechanical Designer- Reg No: Plumbing D 'signer: 0 Reg No: e V Signature is requir I d,' where Florida Law requires design to be performed by registered design professionals. Typed na�nes and registration numbers may be used where all relevant information is contained on signed/sealed plans. 3 Project: HANGARS Title: HANGERS 11 & III Type: Office (WEA File: DAYTONABEACH.TMY) Whole Building Compliance Design Reference Total 96.55 100.00 $1,570 $1,623 ELECTRICITY(Mul 96.55 100.00 Wh/$) 31097 $1,570 32268 $1,623 AREA LIGH,TS 18.00 20.91 5788 6751 $292 $340 MISC EQUIP T 13.64 13.64 4404 4404 $222 $222 PUMPS & Is 0.09 0.09 32 32 $2 $2 SPACE COOL 25.64 21.36 8258 6889 $417 $347 VENT ANb 39.18 44.00 12615 14192 $637 $714 Credits & Penaltie if any): Modified Points: 96.55 S�( PASSES External Lighting Compliance Description Category Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sqft or ft) None 1/3/2007 EnergyGauge FLA/COM 2004 v3.00 4 Project: HANGARS Title: HANGERS Il & III Type: Office (WEA File: DAYTONABEACH.TMY) Lighting Controls Compliance �,C"nym Ashrae Description Area No. of Design Min Compli- EI) (sq.ft) Tasks CP CID ance PrOZo I Sp 1 17 Office - tnclosed 2,004 1 4 1 PASSES PASSES Project: HANGARS Title: HANGERS H & III Type: Office (WEA File: DAYTONABEACO/TMY) System Report Compliance Prosyl System 1 Constant Volume Air Cooled No. of Units Split System < 65000 Btuilr 1 Component Cat / ory Capacity Design Eff Design 1[PLV Comp- 7 Eff Criteria IPLV Criteria liance Cooling System Air Cobled < 65000 Btu/h 13.00 13.00 9.00 PASSES CoolTg Capacity Air Handling Air Handler (Supply) - 0.80 0.90 PASSES System -Supply Consiant Volume PASSES Plant Compliance Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV IPLV liance None 1/3/2007 EnergyGauge FLA/COM 2004 v3.00 5 Nyater Heater Compliance Description Type Category Design Min Design Max Comp Eff Eff Loss Loss Hance -7---J None Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick[in] Thick[in] [F] SF.FJ None Project: HANG Title: HANGERS Type: Office (WEA File: DA Category Infiltratio7 System 111-!12- & III ONABEACH.TMY) Other Required Compliance Section Requirement (write NIA in box if notapplicable) Check 406.1 WltraflOn Criteria have been Tnet 407.1 0 HVAC Load sizing has b'e,-n nprffr,..,4 4