SCOPE:
This NOA is being issued under the applicable rules a d regulations governing the use of construction materials. The
documentation submitted has been reviewed and accep ed by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allo, ed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stked below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas othe than Miami Dade County) reserve the right to have this product
1
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. R reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Se, tion that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has b en designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Flori a Building Code.
DESCRIPTION: 26 ga. Coastal 5V Roof Panel
LABELING: Each unit shall bear a permanent label
statement: "Miami -Dade County Product Control ApI
RENEWAI, of this NOA shall be considered after a rc
in the applicable building code negatively affecting the
the manufacturer's name or logo, city, state and following
i", unless otherwise noted herein.
application has been filed and there has been no change
.nance of this product.
TERMINATION of this NOA will occur after the expir�tion date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or proc ss. Mi!use of this NOA as an endorsement of any product, for
. Ill
sales, advertising or any other purposes shall automatica � terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be
shall be available for inspection at the job site at the
This NOA renews NOA# 14-0520.02 and consists of
The submitted documentation was reviewed by Alex
�d to the user by the manufacturer or its distributors and
of the Building Official.
I through 5.
7-(, f - V'
CMIAMIi!DADECO NOA No.: 19-0807.02
Expiration Date: 08/21/24
Approval Date: 08/15/19
Page I of 5
ROOFING SYSTEm APPROVAL:
Category:
Roofing
Sub-Cate2ory:
Metal, Panels (N
Material:
Steel
Deck Type:
Wood
Maximum Design Pressure
-156.5 psf
TRADE NAmEs OF PRODUCTS MANUF
I
Product
Dimensions
26 ga. Coastal 5V-
I = varies
Crimp Roof Panel
w = 26"
(24" coverage)
h = 3/8"
Min. Thickness 0.0 18"
(26ga.)
Min. Yield Strength: 67ksi
Trim Pieces
I varies
w varies
Min. Thickness 0.0 18"
(26ga.)
MANUFACTURING LOCATION:
1. Horseshoe Beach, FL.
2. Sebring, FL.
3. Stuart, FL.
EVIDENCE SUBMITTED:
Test Agenc Test Identifier
PRI Construction Materials VLS-004-02-01
Technologies VLS-005-02-01
OR LABELED By APPLICANT:
Test Product
ffications Description
A'S 110 Corrosion resistant, galvanized, preformed,
Valspar coated, prefinished, metal panels.
TA� 110 Standard flashing and trim pieces.
Manufactured for each panel width.
Force Engineering & Testing Inc. 117-0065T-07A-C
Test Name/Repor
ASTM G 155
ASTM G 23
TAS 125
Date
02/22/13
02/22/13
08/02/13
Farabaugh Engineering and T215-08A TAS 100 08/13/14
Testing, Inc.
NOA No.: 19-0807.02
Expiration Date: 08/21/24
Approval Date: 08/15/19
Page 2 of 5
E
APPROVED ASSEMBLIES:
System A:
Deck Type:
Deck Description:
Maximum Uplift
Pressure:
26 ga. Coastal 5V-Crimp Roo Panel
Wood, Non -insulated
New Construction 19/32" or grea �er plywood or wood plank, or for re -roofing "/32" or greater
plywood.
See Table A below.
Deck Attachment:
In accordance with applicable B uilding Code, but in no case shall it be less than 8d ring
shank nails spaced 6" o.c. In re�oofing, where the deck is less than "/32" thick (Minimum
a
"/32") the above attachment meth d must be in addition to existing attachment.
%a
Underlayment:
Minimum underlayment shall be ASTM D 226 Type II installed with a minimurn 4" side -
lap and 6" end -laps. Underlaymerit� shall be fastened with corrosion resistant tin -caps and 12
gauge 1 1/4" annular ring -shank nail�, spaced 6" o.c. at all laps and two staggered rows 12"
o.c. in the field of the roll. Or, any pproved underlayment having a current NOA.
Fire Barrier:
Any approved fire barrier having a current NOA. Refer to a current fire directory listing for
fire ratings of this roofing system as�embly as well as the location of the fire barrier within
the assembly. See Limitation # 1.
Valleys:
Valley construction shall be in comp iance with Roofing Application Standard RAS 133 and
with Gulf Coast Supply & Manufc ring LLC's current published installation instructions.
Metal Panels and
Install the "26 ga. Coastal 5V-Crimp.Koolvanel" and accessories in compliance with Gulf
Accessories:
Coast Supply & Manufacturing LLC s current, published installation instructions and details.
Flashing, penetrations, valley construction and other details shall be constructed in
compliance with the minimum require ents provided in Roofing Application Standards RAS
133. T
Panel fasteners shall be #9-15 x 1-1/2" s6lf drilling, self tapping, hex head screws with sealing
washer of sufficient length to penetrate ihrough the sheathing a minimum of 3/ 16inch.
I
Fasteners shall be installed at a maximu� spacing as listed in Table A below parallel to the
slope. Fasteners shall be installed at a maximum of 12" o.c. at panel edge. See detail herein.
TABLE A
MAximum DESIGN PRESSURES
Roof Areas
Field
Perimeter and Corner'
Maximum Design Pressures
-108.5 psf
-156.5 psf
Maximum Fastener Spacing
12" o.c.
6" o.c.
1. Extrapolation shall not be allowed
MLALMI-DADE COUNTY NOA No.: 19-0807.02
FH I 6=1 Expiration Date: 08/21/24
Approval Date: 08/15/19
Page 3 of 5
LimITATIONS
1. Fire classification is not part of this acceptance; ref�r to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. The maximum designed pressure listed herein shall �e
and comers). Neither rational analysis, nor extrapolatio
pressure zones (i.e. perimeters, extended comers a4c
3. Panel shall be roll formed in continuous lengths fro
Roofing Application Standard RAS 133. '7
4. All panels shall be permanently labeled with the man�
"Miami -Dade County Product Control Approved" or,
below. All clips shall be permanently labeled with the
19TIT61—:
applicable to all roof pressure zones (i.e. field, perimeters,
n shall be permitted for enhanced fastening at enhanced
omers).
eave to ridge. Maximum lengths shall be described in the
5. All products listed herein shall have a quality assurance
Rule 6 1 G20-3 of the Florida Administrative Code.
WMAMI-DADECOUN
�gjamlynolwo
urer's name and/or logo, and the following statement:
the Miami -Dade County Product Control Seal as seen
ufacturer's narne and/or logo, and/or model.
it in accordance with the Florida Building Code and
NOA No.: 19-0807.02
Expiration Date: 08/21/24
Approval Date: 08/15/19
Page 4 of 5
DRAWINGS
DETAIL A
26 GA. COASTAL 5V-CRimp ROOF PANEL
24" Cove7ge
#9-15 x 1 1/2" Woodgrip Screw /- #9-15 x 1 1/2" Woodgrip Screw
5V-Crimp Panel
Plywood Decking
(By others)
Moisture Barrier
(By others)
SeeTable A
Herein for Maximum
Fastening Spacing
END OF THIS ACCEPTANCE
5V Panel
MLAMI-DADE COUNTY NOA No.: 19-0807.02
�gnmel,g)] Expiration Date: 08/21/24
Approval Date: 08/15/19
Page 5 of 5
�' I I
SHOP DRAWING REVIEW
William Arthur
(4chitectlbuilder
AP,
APPROVED W/O COMMENT
APPROVED AS NOTED
REJECTED
RESUBMIT
THIS REVIEW IS FOR GENERAL
CONFORMANCE NTH THE DESIGN
CONCEPT AND CONTRACT
DOCUMENTS.
Markings or comments shall not be construed as
relieving the CONTRACTOR from compliance with the
project, plans, and specifications nor departure
therefrom. The CONTRACTOR remains responsible
a
details and a cy, for confirming and con, g all
quantities, job corditions and dimensl or selecting
fabrication proWC,.- as. for tech of assembly and
constructior, r P. his wor a
to_" ing his work in a safe
manner. 'Al"111
SILVA