Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEDepartment FLORIDA ENERGY EFFICIEN FORM 60OA-93 Residential Whole! PROJECT NAME: i'i AND ADDRESS: Jack Island Rd Ft.Pierce,F1GQANNkD OWNER: Wickard 1. New construction or At 2. Single family detached or Multif 3. If Multifamily -No. of units 4. If Multifamily, is this a worst 5. Conditioned floor area '(sq.ft.) 6. Predominant eave overhang (ft.) 7. Porch overhang length (ft.) 8. Glass area and type: a. Clear Glass b. Tint, film or solar screen 9. Floor type and insulation: a. Slab on grade (R-value, peritn 10.Net Wall type area and insulat!i a. Exterior: 1. Concrete (Insula, a. Exterior: 2. Wood frame (Insu b. Adjacent: 2. Wood frame (Insu II.Ceiling type area and insulatio of Community Affairs SN: 8274 Y CODE FOR BUILDING CONSTRUCTION uilding Performance Method A CENTRAL UILDER: Georgiton Construction ERMITTING CLIMATE FFICE: St.Lucie ZONE: 41_1 51_1 61_1 ERMIT NO. JURISDICTION NO.661000 CK ly attached se (yes/no) ter) n: on R-value) ation R-value) ation R-value) a. Under attic (Insulation -value) 12.Air distribution systems a. Ducts (Insulation + Loca:ion) 13.Cooling system I 14.Heating System: 15.Hot water system: 16.Hot Water Credits: (HR-Heat R�covery, DHP-Dedicated Heat Pum ) 17.Infiltration practice: 1, 2 o' 3 18.HVAC Credits (CF-Ceiling Fan, CV -Cross vent, HF-Whole house fan, RB Attic radiant barrier, MZ-Multizone) 19.EPI (must not exceed 100 poin s) a. Total As -Built points b. Total Base points ---------------------------------------- I Hereby certify that the plans and specifications covered by this alcu- lation are in compliance with t e Florida Energy Code. PREPARED BY: a,,L DATE: �7 1 I hereby certify that this building is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: 1. New Construction 2. Single -Family 3. 0 4. 5. 3179.00 6. 2.00 7. 10.00 Single Pane Double Pane 8a. O.Osqft 0.00sqft 8b. O.Osqft 578.40sqft 9a.R= 0.00 , 345.00 ft 10a-1 R= 8.20, 2225.00sqft 10a-2 R=11.00, 256.00sqft_ lOb-2 R=11.00, 512.00sqft_ lla.R=30.00 , 3179.00sqft 12a. R= 6.00 , uncond 13. Type: Central A/C EER: 10.00 14. Type: Strip Heat COP: 1.00 15. Type: Electric EF: 0.96 16. 17. 2 18. CF 19. 95.74 19a. 51818.23 19b. 54125.93 ---------------------------------------- Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance in accordance with Section 553.908 F.S. BUILDING OFFICIAL: DATE: SUMME CALCULATIONS BASE AS -BUILT GLASS ---------------- ORIEN AREA x BSPM = POINTS SC ORIEN AREA x SPM x SOF POINTS --------------------------------- NE 137.40 82.2 11294.3 _TYP --- DBL ------------------------------------------ TINT NE 48.0 63.4 .86 2627.3 DBL #NT NE 4.0 63.4 .58 147.1 DBL TINT NE 32.4 63.4 .81 1659.3 DBL ;INT NE 40.0 63.4 .84 2129.0 DBL �INT NE 13.0 63.4 .76 630.1 SE 132.20 82.2 10866.8 DBL TINT SE 23.2 89.4 .79 1647.4 DBL TINT SE 96.0 89.4 .83 7123.4 DBL TINT SE 13.0 89.4 .68 794.5 Sw 228.80 82.2 18807.4 DBL TINT Sw 40.0 89.4 .79 2840.4 DBL TINT Sw 72.0 89.4 .32 2081.2 DBL FINT SW 32.4 89.4 .75 2162.8 L DBL INT Sw 16.2 89.4 .75 1081.4 DBL L INT Sw 16.2 89.4 .75 1081.4 L DBL T TINT Sw 4.0 89.4 .42 150.2 L DBL T TINT SW 48.0 89.4 .83 3561.7 NW 80.00 82.2 6576.0 L DBL T TINT NW 40.0 63.4 .86 2189.4 L DBL T TINT NW 40.0 63.4 .86 2189.4 ---------------------------------- .15 x COND. FLOOR TOTAL GLASS -------------------------------------------- J. x GLASS ADJ GLASS GLASS AREA AREA FJCTOR POINTS POINTS POINTS ---------------------------------- .15 3,179.00 578.40 -------------------------------------------- .824 47,544.48 39,197.07 1 34,096.03 NON GLASS ------------ AREA x BSPM = POINTS T PE --------------------------------------------- R-VALUE AREA x SPM = POINTS --------------------------------- WALLS ---------------- Ext 2481.0 1.0 2481.0 EX LtWtBlock Int 8.2 2225.0 .51 1134.8 Ex Wood Frame 11.0 256.0 1.90 486.4 Adj 512.0 .7 358.4 Ad' Wood Frame 11.0 512.0 .70 358.4 DOORS ---------------- Ext 66.0 4.8 316.8 E71,t Insulated 66.0 4.80 316.8 Adj 18.0 1.6 28.8 Adj Insulated 18.0 1.60 28.8 CEILINGS ------------- UA 3179.0 .6 1907.4 FLOORS --------------- Slb 345.0 -31.8 -10971.0 U,der Attic 30.0 3179.0 .60 1907.4 S ab-on-Grade .0 345.0 -31.90 -11005.5 INFILTRATION --------- 3179.0 10.9 34651.1 �ractice #2 3179.0 10.90 34651.1 TOTAL SUMMER POINTS 67,969.57_ 61,974.18 TOTAL x SYSTEM COOLING OTAL x CAP x DUCT x SYSTEM x CREDIT = COOLING SUM PTS MULT POINTS OMPON RATIO MULT MULT MULT POINTS ------------------------------------------------------------------------------- 67,969.57 .37 25,148.74 1 61,974.18 1.00 1.100 .340 .860 19,933.38 WINTER CALCULATIONS BASE AS -BUILT "GLASS ---------------- ORIEN AREA x BWPM = POINTS TYP SC ORIEN AREA x WPM x WOF POINTS --------------------- NE 137.40 -3.4 ---4-6-7--.2 ----- DB_L_T�� ------ NE ---- ---- 48.0 --- ----- 4.2 --- ---- 1.22 ----- ---- 246.4 DBL TINT NE 4.0 4.2 1.63 27.4 DBL INT NE 32.4 4.2 1.30 176.4 DBL INT NE 40.0 4.2 1.25 210.7 DBL �INT NE 13.0 4.2 1.35 73.9 SE 132.20 -3.4 -449.5 DBL TINT SE 23.2 -10.4 .83 -201.3 DBL TINT SE 96.0 -10.4 .87 -864.2 DBL TINT SE 13.0 -10.4 .72 -97.3 Sw 228.80 -3.4 -777.9 DBL TINT Sw 40.0 -10.4 .83 -347.1 DBL �INT Sw 72.0 -10.4 -.04 31.6 L DB ' INT Sw 32.4 -10.4 .79 -265.1 DB� INT Sw 16.2 -10.4 .79 -132.5 DBL T TINT Sw 16.2 -10.4 .79 -132.5 DBt T TINT Sw 4.0 -10.4 .28 -11.6 DBL TINT Sw 48.0 -10.4 .87 -432.1 NW 80.00 -3.4 -272.0 DBL TINT NW 40.0 4.2 1.22 205.3 DBL TINT NW 40.0 4.2 1.22 205.3 ---------------------------------- .15 x COND. FLOOR / TOTAL GLASS = +ADJ. -------------------------------------------- x GLASS ADJ GLASS GLASS AREA AREA F CTOR POINTS POINTS POINTS ------------------------------------------------------------------------------- .15 3,179.00 578.40 .824 -1,966.56 -1,621.29 -1,306.77 NON GLASS ------------ AREA x BWPM = POINTS T PE R-VALUE AREA x WPM = POINTS --------------------------------- WALLS ---------------- --------------------------------------------- Ext 2481.0 1.1 2729.1 Ex LtWtBlock Int 8.2 2225.0 1.72 3827.0 Ex Wood Frame 11.0 256.0 2.00 512.0 Adj 512.0 1.8 921.6 A ' Wood Frame 11.0 512.0 1.80 921.6 DOORS ---------------- Ext 66.0 5.1 336.6 E t Insulated 66.0 5.10 336.6 Adj 18.0 4.0 72.0 A j Insulated 18.0 4.00 72.0 CEILINGS ------------- UA 3179.0 .6 1907.4 U der Attic 30.0 3179.0 .60 1907.4 FLOORS --------------- Slb 345.0 -1.9 -655.5 Slab -on -Grade .0 345.0 2.50 862.5 INFILTRATION --------- 3179.0 4.1 13033.9 ractice #2 3179.0 4.10 13033.9 TOTAL WINTER POINTS 16,723.81 --- - ------ 20,166.23 TOTAL x SYSTEM HEATING I �UFAL x CAP x DUCT x SYSTEM x CREDIT = HEATING WIN PTS MULT POINTS COMPON RATIO MULT MULT MULT POINTS --------- ---- ---- 16,723.81 __ 1.10 --- 18,3-9-6-.-1-9--1-120,166.23-1.00-1.100 ------------ --------- ---- ----- ----- ----- --- 1.000 ---- 1.000--22,182.86 --------- I WIVIT. HEATING BASE AS -BUILT IT, "NUM OF x MULT TOTAL TANK , OLUME EF TANK x MULT x CREDIT TOTAL BEDRMS RATIO MULT ------------------------------------------------------------------------------- 5 3 3527.0 10,581.00 0 .96 1.000 3234.0 1.00 9,702.00 SUMMARY BASE AS -BUILT COOLING HEATING HOT WATER TOTAL COOLING HEATING HOT WATER TOTAL POINTS + POINTS + POINTS = POiNTS POINTS + POINTS + POINTS = POINTS -------------------------------- - -------------------------------------------- 25148.7 18396.2 10581.0 54,12 .93 19933.4 22182.9 9702.0 51,818.23 *XI 95.74 ENERGY GUIDE For detailed information of the EPI rating number or for any ITEM listed, ask vour Builder for PI= 95.7 DCA. Form 60OA-93 or Form 60OB-93 0 10 20 30 40 50 60 70 80 90 100 --------------- ---------------------- X--1 The max'imum allowable BPI is 100. T�e lower the BPI the more efficient the home RESIDENTIAL BiNEZ-' PERFORMANCE RATING SHEET ITEM HOME VALUE Low Efficiency High Efficiency WINDOWS ..................... INSULATION .................. Ceiling R-Value ......... 30.0 Wall R-Value ......... 8.2 Floor R-Value ......... 0.0 AIR CONDITIONER ............. EER ....................... 10.0 HEATING SYSTEM .............. 0 Electric COP ............. 1. WATER HEATER ................ Electric EF .............. 0.96 Gas EF .............. 0.00 Solar EF .............. OTHER FEATURES .............. SINGL CLR DBL TINT Tint I -------------------- X1 R-10 R-30 I-------------------- X1 R-0 R-7 I-------------------- X1 R-0 R-19 ix-------------------- I 9.7 EER 16.0 Ix-------------------- I 2.50 COP 4.19 ix-------------------- I 0.88 0.96 1 -------------------- X1 0.54 0.90 1 --------------------- 1 0.40 0.80 1 --------------------- I I certify that these energy sa�ing features required for the Florida Energy Code have been installed in this house. Builder Address: Signature: Date: City/Zip L Florida Energy Code for Building Construction - 1993 .1 Florida Department of Community Affairs FL-EPL CARD93 ri RIGHT-J LOAD AND File name: GEOWIC-3.RSR For: GEORGITON CONST. PO BOX 3230 FT. PIERCE 466-5489 By: ASSOCIATED AIR OF PORT 1538 NIEMEYER CIR. PORT ST. LUCIE (561) 335-7089 Job 9: WICKARD RES / ST. LUC E Wthr: Zone: Entire House WINTER DESIGN CONDITIONS Outside db: 42 OF Inside db: 70 OF Design TD: 28 OF I HEATING SUMMARY I Bldg. Heat Loss 33321 Ventilation Air 0 Vent Air Loss 0 Design Heat Load 33321 INFILTRATION Method Simplif ed Construction Quality A�ile age Fireplaces I � 1 HEATING OLIIS Area (sq.ft.) 1931 931 Volume (cuff.) 21586 21586 Air Changes/Hour 1.0 0.4 Equivalent CFM 360 144 HEATING EQUIPMENT SUM Y Make TRANE UNITARY Trade TRANE TWE048C14-B %4ENT SUMMARY 12/30/97 FL 34948 ST. LUCIE F L 34952 CO. Fort Pierce FL SUMMER DESIGN CONDITIONS Outside db: 90 OF Inside db: 75 OF Design TD: 15 OF Daily Range L Rel. Hum.: 50 % Grains Water 62 gr SENSIBLE COOLING EQUIP LOAD SIZING Structure 35909 Btuh Ventilation 0 Btuh Design Temp. Swing 3.0 OF Use Mfg. Data n Rate/Swing Mult. 0.95 Total Sens Equip Load 34113 Btuh LATENT COOLING EQUIP LOAD SIZING Internal Gains 1380 Btuh Ventilation 0 Btuh Infiltration 6079 Btuh Tot Latent Equip Load 7459 Btuh Total Equip Load 43368 Btuh COOLING EQUIPMENT SUMMARY Make TRANE UNITARY Trade Trane XE 1000 TTR048C TWE048C14-B Efficiency UU.0 AhUh Efficiency 10.0 EER Heating Input j0 Btuh Sensible Cooling 33250 Btah Heating Output 10 Btuh Latent Cooling 14250 Btuh Heating Temp Rise 0 OF Total Cooling 47500 Btuh Actual Heating Fan 16PO CFM Actual Cooling Fan 1600 CFM Htg Air Flow Factor 0.0.48 CFM/Btuh CIg Air Flow Factor 0.045 CFM/l3tuh Space Thennostat Load Sens Heat Ratio 83 MAIN ul-J, J: I LIL MI. ft-a(nte: C1 NT Ver 9 . V . U/- of IN A0.KzUz90 Printout certified by ACCA to meet all requirements of Manual Form i . Ri&t-S-aite: Ver 4.0.02 SIN RSR20246 MANuAL J-. 7th Ed. RIGHT-i WINDOW DATA Job 4 WICKARD RES ST. LUCIE CO. File name GEOWIC-3.RSR 12/30/97 W S D W G L s S N A S 0 0 W c s N K I A L 0 T H V G N H v v 11 H N H D y R L A W R A H L G c R R G T A A IN L z E M D G Z L 0 x y T m R R BREAKFAST a n ne a c n n n n 1 go 1.0 0.0 0.0 1.0 60.0 38.0 0.0 KITCHEN a n ne a c n n n n 1 90 1.0 0.0 0.0 1.0 60.0 13.0 0.0 DINING RM b n se a c n n n n 1 go 1.0 0.0 0.0 1.0 74.0 96.0 0.0 LAUN RM a n se a c n n n n 1 go 1.0 0.0 0.0 1.0 74.0 13.0 0.0 KIT BATH LIVING RM b n sw a c n n n y 1 90 1.0 8.0 1.5 8.0 74.0 72.0 72.0 DANCE STUDIO • n sw a c n n n n 1 90 1.0 0.0 0.0 1.0 74.0 38.0 0.0 • n nw a c n n n n 1 90 1.0 0.0 0.0 1.0 60.0 38.0 0.0 FOYER • n nw a c n n n y 1 90 1.0 7.0 3.5 6.0 60.0 12.0 0.0 STUDY • n nw a c n n n n 1 90 1.0 0.0 0.0 1.0 60.0 38.0 0.0 T) ICT S STFM qTTMMARY S,/N I R.SR20246 c. S File Name: GEOWIC-3.RSR Rigl Job Number: WICKARD RES / ST. LUCIE Zone: Entire House For GEORC-TTCN C(:W,9T- External Static Pressure: Pressure Losses: Available Static Pressure: Friction Rate: Actual CFM: Total Effective Length (TEL): Ver 4.0.02 12/30/97 HEATING 0.00 rwC 0.00 rwC 0.00 I -WC 0.150 rWC / 100 ft 1600 CFM 0 Fee SUPPLY BR�Cff DETAIL TABLE COOLING 0.00 IWC 0.00 IWC 0.00 rwC 0.150 I ­WC / 100 ft 1600 CFM Name Htgo Btuh C19 Btuh Htg CFM Clg CFM Dsn FR Vel fpm Dot Dia Rect size Duct Mad Trnk BREAKFAST 0 3017' 0 134 0.150 685 6 Ox 0 VlFx stl KITCHEN 0 3073, 0 137 0.150 697 6 Ox 0 V1Fx M DINING RM 0 3380, 0 lal 0.150 767 6 Ox 0 V1Fx stl DINING RM-A 0 3380 0 151 0.150 767 6 Ox 0 V1Fx stl DINING RM-B 0 3380 0 151 0.150 767 6 Ox 0 VlFx stl LATIN RM 0 1966 0 88 0.150 642 5 Ox b VlFx M KIT BATH 0 96 0 4 0.150 49 4 Ox 0 V1Fx M LIVING RM 0 2778 0 124 0.150 630 6 Ox Q VlFx ST3 LIVING RM-A 0 2778 0 124 0.150 630 6 Ox 0 V1Fx ST3 DANCE STUDIO 0 3394 0 151 0.150 770 6 Ox 0 V1Fx ST2 DANCE STUDIO -A 0 3394 0 151 0.150 770 6 OX 0 VlFx ST2 FOYER 0 1813 0 81 0.150 926 4 Ox 0 V1Fx ST2 STUDY 0 3460 0 154 0.150 785 6 Ox 0 VlFx ST2 SUPPL� TRUNK DETAIL TABLE Trunk Htg Cg Vel Duct Rect Duct Duct Name Type O-FM CF fpm Diam, Size Material Trunk stl Peak CFM 0 58 746 12 0 x 0 VinlFlx M M Peak CFM 0 160 733 20 0 x 0 VinlFlx ST3 Peak CFM 0 78 734 14 0 x 0 VinlFlx M ST2 Peak CFM 0 53 I 684 12 0 x 0 VinlFlx ST3 RiT BRANCH DETAIL TABLE Nwne Diffus size Htg Btuh Clg Htg Btu� CFM C1g CFM Dsn FR Vel finp Dot Dia Rect Size Duct Matl Trunk rbl 0 x 0* 0 359'09 0 1600 0.150 733 20 Ox 0 VlFx SIN RSR20246 DUCT SYSTEM SUMMARY File Name: GEOWIC-3.RSR Right -Suite: Ver 4.0.02 12/30/97 Job Number: WICKARD RES / ST. LUCIE CO. Zone: Entire House For: GEORGITON CONST. External Static Pressure: Pressure Losses: Available Static Pressure: Friction Rate: Actual CFM: Total Effective Length (TEL): HEATING 0.00 lWC 0.00 IWC 0.00 IWC 0.150 IWC / 100 ft 1600 CFM 0 Feet COOLING 0.00 IWC 0.00 rwC 0.00 IWC 0.150 IWC / 100 ft 1600 CFM SUPPLY TRUNKS AND BRANCHES - SCHEMATIC TREE DIAGRAM KITCHEN —136. LAUN RM —87. KIT BATH — 4. BREAKFAST —134. stl 586. DINING RM —150. DINING RM —150. DININGRM —150. LIVING RM — 123. ST3 784. LIVINGRM —123. DANCE STUD —151. ST2 537. DANCE STUD —151. FOYER —80. STUDY 154. rbI V I RETURN TRUNKS AND BRANCHES — 1600 — < —NO TRUNK indicates branches and tunks; numbers indicate CFM's M 1600 %j OL %A t C,4 Ps 1�. L %) .1 ve a A +c - 40, CA rn*��