Loading...
HomeMy WebLinkAboutBUILDING - PLAN01114 0 Lu --, Cn GROUT ALL CELLS u- > SOLID BELOW GRADE LU -j Lu (TYPICAL) < 00 8" CMU HEADER BLOCK PROVIDE DOWELS SAME SIZE & NUMBERAS VERT. REINF.STD. 900 HOOK ALTERNATE SETTING. SEE FOOTING SCHED// FOR REINFORCING _ SEE FTG. SCHD. REINFORCED CMU WALL SEE PLAN MARK AND SCHEDULE CONCRETE SLAB SEE PLAN. Lu < ui -1 V) CL Lu Z: --l') PROVIDE INSPECTION CLEAN OUT BELOW 100'-0" WALL AND FOOTING SECTION 3/411= 11-01, FILL JOINT WITH SEALAN I 1 /&'TO 114' SAW CUT SEE PLAN FOR SLAB7AND REINF. Ci —1 1/2" CLEAR FLOOR CONTROL JOINT FILL JOINT WITH SEALANT �- I NOTE: LOCATION OF CONSTRUCTION JOINT SHALL BE AT THE DISCRETION OF GENERAL CONTRACTOR. N.T.S. 1 /9'T0 114' SAW C T SEE PLAN FOR SLAB'T'AND REINF. u T 1 1/2" CLEAR PROVIDE CONTINUOUS ci PREFORMED BOND BREAK BETWEEN SLABS (�.,�FLOOR CONSTRUCTION JOINT 511 7 El 21-011 Cmu TYPE 8" x 24" x 24" 5 # 5 VERT. FULLY GROUT REINFORCED CELLS N.T.S. 511 El FIE I IV 21-011 1 Cmu TYPE 8" x 16" x 24" 4 # 5 VERT. FULLY GROUT REINFORCED CELLS BB-1 8" CMU BOND BEAM WITH I - #7 CONT. z 00'1� 8" CMU HEADER BLOCK PROVIDE DOWELS SAME SIZE & NUMBERAS VERT. REINF.STD. 900 HOOK ALTERNATE SETTING. , mm�vm z <1 Cie CONCRETE SLAB 0 CL Lu SEE PLAN. 0 Lu (n �,: Lu -j Fj- Lu 7 Lu Z w CL PROVIDE INSPECTION CLEAN OUT BELOW 1100-4- SEE FOOTING SCHEID FOR FOR DIM. REINFORCING SEE FTG. SCHID. WALL SECTION AT WIN (�2 3/411= 11-01, SEE PLAN OR BEAM SCHEDULE FOR BOND 48 DIA. OR BEAM STEEL (I # 7 TYP. MIN.) 30" MIN. DOW SILL PROVIDE SINGLE TIE BAR OF AREA EQUAL TO PROVIDE (2) REINF. SOLID TOTAL BOND BEAM STEEL CELLS (TYP.) @ INTERSECTION AREA (1 #7 U.N.O.) (MIN. 1 #5 EA. OR AS SCHED.) INTERSECTION DETAIL SEE PLAN OR BEAM SCHEDULE FORBONID�BEAM 48 DIA OR STEEL(I # 7 TYP. MIN.) PROVIDE (1) REINF. SOLID CELLS (TYP.) @ CORNERS (MIN.-1 #5 EA. OR AS SCHEDULED.) CORNER DETAIL PROVIDE SINGLE TIE BAR OF AREA EQUAL TO TOTAL BOND BEAM STEEL AREA (1 #7 U.N.C.) BOND BEAM & CMU REINFORCEMENT F. I Cmu TYPE (9 8" x 16" x 16" 3 # 5 VERT. FULLY GROUT REINFORCED CELLS Cmu TYPE--- 8" x 16" x 24" 4 # 5 VERT. FULLY GROUT REINFORCED CELLS N.T.S. COLUMN TYPES W z WALL BEYOND 0 0 z 055 -i LL a. ;� Lu Lu -j Lu u- ui 0) Lu z: �t� ]NL, a (n 0 SEE FOOTING SCHEDULE- "W" SEE SCHEID. TYP THICKENED EDGE (TE-1) AT DOOR 3/4"= 11-01, PREFAB TEE 9 Ga. GALV. 11-611 MIN. L) PREFAB STANDARD 9 Go GALV CORNER 10 STANDARD 9 Ga. GALVANIZED HORIZONTAL MASONRY WALL REINF. LADDER TYPE IN EVERY Nk OTHER BLOCK COURSING (16" A v a/c.) TYP. UNLESS NOTED — MASONRY WALL UNIT (8 —M N.T.S. Cmu TYPE 8" x 16" 2 # 5 VERT. FULLY GROUT REINFORCED CELLS ALL CORNER BARS TO BE SAME SIZE, NUMBER & SPACING AS HORIZ. BARS IN FOOTING & BEAMS ...... FOOTING & BEAM BAR ARRANGEMENT D JEF-11E Cmu TYPE OOK ETAIL N.T.S. 8" x 24" x 32" 6 # 5 VERT. FULLY GROUT REINFORCED CELLS 10 -1 N 1k Lu Cn U < CL FL < �7- U < ix i (L 0 ui 0 Lu V) -i u- ui i Lu PROVIDE DOWELS SAME SIZE & NUMBERAS VERT. REINF.STD. 900 HOOK ALTERNATE SETTING. SEE FOOTING SCHEID FOR REINFORCING FOR DIM. SEE FTG. SCHD. REINFORCED CMU WALL SEE PLAN MARK AND SCHEDULE 1/2" PREMOLDED JOINT FILLER WITH SEALANT < Lu CONCRETE SLAB v"7 z ui Lu (4 Lu Lu u V) (/) hi, PROVIDE INSPECTION CLEAN OUT BELOW 100'-0" (�SECTION AT DIVIDING WALL 4) 11-01. ANU 1h1UKt:NtU EDGE - SEE PLAN nDOOR OPENING CONST JNT o N.T.S. z NOTE: SEE ARCH. DWGS FOR LOCATION OF RECESSED AREAS 0 ui 0 Lu u- 2� Lu 7L Lu Ot CL 0 Lu 0 Lu __j tn u- 5 Lu -i uj 3: 2 # 5 CONT. < z 3: CONCRETE SLAB Cie -7: SEE PLAN 0 U 0 T-7 — TYPICAL RECESSED FLOOR 3/4"= 11-01, 0z Lu > 0 REINFORCED CMU WALL SEE PLAN MARK AND SCHEDULE LAB ON GRADE D- )n (n Z> I., min flcz) 7 Erwood Place COMPACTED St GRADE Boynton Beach, FL 33426 (4) #5 CONT. (561) 308 6694 EQ SPACED www.FCArchitecture.com #5 AT I TOC AA26002566 BOT :VIEVVED FOFt RE OMPLIANCE D5GN L. VAN DYK cooE C ST. LUCIE COUNTY DRWN L. VAN DYK SECTION AT DIVIDING WALL BOCC AFVD A. SLOCOMBE -,A$lt ! 12 3/4 ,V = -01, f, f f 2 ruRE, 2019. ALL PIGHTS RESERVED m :t ca U_ 0 a. w 0 -1 F- W FIN. FL EL. 110'-4" BB-1 SEE SCHEDULE 2 - 2x4 P.T BLOCKING BETWEEN TRUSSES & ANCHOR TO TOP OF LEDGER WITH 16d NAILS @ 8" O.C. AGGERVBOLTS BOTTOM CHORD OF TRUSS SHALL BE BRACED W/2X4 BOTT. CHORD BRACING W/(2) 10d NAILS AT EACH TRUSS 2 - 2x8 P.T. CONT. ATTACH TO BOND BEAM W/5/8"OV BOLTS @ 24" O.C. MAX MIN. 3 �' EMBED. WALL SECTION AT 2nd FLOOR 3/411= 1 0-01, ROOF WORK POINT PLAN MARK & SCHEDULE BOND BEAM BB-2 SEE Wmml < w co bo LL 0 TRUSS W SEE PLAN 0 4"IVIIIN TRUSS BEARING CONNECTORS E 4F 1y2p 8_ 4 S I ECTION 3/4 1=1 1-01, BOND BEAM BB-2 SEESCHEDULE Jul --e, eu I Z9 TRUSS SEE PLAN 2x6 (PT) HORIZ. WD. BLOCKING BETWEEN TRUSSES REINFORCED CMU WALL SEE PLAN MARK & SCHEDULE FIN. FL BB-1 SEE SCHEDULE ROOF WORK w bo POINT U_ 0 (L 0 w _3 F,��W CONNECTORS TYPE F—B] TYPE ' �' 12 11 12 4 ; w< ca TRUSS LL 0 S PL SEE PLAN CL 0 2 - 2x6 LEDGER W/6" x 1/2" EPDXY ANCHT.RS 16" O.C. MIN. 4 . EMBED. REINFORCED CMU WALL SEE PLAN MARK 8' & SCHEDULE SECTION NOTE: DETAILS NOT SHOWN SIMILAR TO SECTI ON 'I' WALL SECTION AT 2nd FLOOR 3/4"= V-01, CONT. TIE BEAM SEE PLAN MARK & SCHEDULE ROOF WORK POINT 8D > W -1 w LINTEL L-3 I - 8" LINTEL BLOCK I - 8" BOND BEAM 4" MIIN TRUSS BEARING CONNECTORS TYPE FC 12 4F- HIP TRUSS SEE PLAN REINFORCED CMU WALL SEE PLAN MARK 8- & SCHEDULE SECTION 8_ 12 4 —7: r TOP/ WINDOW ELEV. 117'-4" CMU WALL BEYOND FIN. FIL EL. 110'-4" BB-1 SEE SCHEDULE WALL BEYOND ELEV. 2 - 2x6 LEDGER W/6" x 1/2" EPDXY ANCHORS 16" O.C. MIN 4 -l!'EMBED. IN FULLY 6ROUTED CELLS WALL SECTION AT 2nd FLOOR 3/41.= 11-01. STUD WAL BOND BEAM BB-2 SEE SCHEDULE 2 - 2X6 LEDGER TRUSS SEE PLAN "8- _TION FIN. FL EL. 110'-4" BB-1 SEE SCHEDULE (2) SIMPSON LSTA 121 STRAPS (OR SIMILAR). ATTACH TO GIRDER WITH 8 - #8d NAILS x 17"' LG. PER STRAP. (TWO STRAPS ON ONE SIDE OF GIRDER ONLY) BOTTOM CHORD OF GIRDERS SHALL BE BRACED W/2X4 BOTT. CHORD BRACING W/(2) I Od NAILS AT EACH TRUSS - 4X4 POST EXTEND FROM FLOOR TO U/S GIRDER ATTACH TO WALL WITH 8 - 6" LG. TAPCONS. ATTACH HANGER STRAPS WITH 8 - #8 NAILS x 1 LG. PER STRAP. WALL SECTION AT 2nd FLOOR 3/4"= V-0" ERS SIMPSON LGUM48-SDS TRUSS HANGER ATTACH TO TRUSS WITH 6 - 1' x 2 -1" TRONG CM2 S DR�YE SDS SCREWS AND Td U WALL WITH FIN. FL :1[1f_F6 - 8 DIA. x 4" LONG TITEN HID ANCHORS. EL. 110'-4" BOTTOM CHORD OF TRUSS SHALL BE BRACED W/2x4 BOTT. CHORD BRACING W/(2) 1 Od NAILS BB-1 _;7ZM AT EACH TRUSS SEE SCHEDULE WALL SECTION AT 2nd FLOOR GIRDERS 3/4"= 1 '-0" V:Oft 41tom'PLIpAcle INV Go OGG SCANNED BY ST LUCIE COUNTY aj z 0 HURRICANE STRAP & ANCHOR SCHEDULE MARK DESCRIPTION RATED UPLIFT CAPACITY MAX UPLIFT LOAD FASTENERS TO TRUSS FASTENERS TO SUPPORT LOCATION 11 FA—] META 16 1450 810 8-10d x 1 NAILS EMBED TRUSS TO TIE BEAM 7B HETAL 12 1040 465 10-10d x 1 NAILS EMBED TRUSSS TO TIE BEAM 7C (2) FGTR 9400 8820 36-1/4" x 3" SIDS �4- I" x 5"TITEN HD GIRDER TRUSS TO TIE BEAM E H2.5T 425 315 5 - 8d x 1 J"NAILS I 5-8dxl j" NAILS ROOF O/HANG AT GABLE END NOTE: ALL STRAPS AND ANCHORS ARE SIMPSON STRONGTIE OR EQUIVALENT. STD. 90* - ACI HOOK TOP CONT ACI CLASS "B" LAP SPLICES AT MID -SPAN BOTT. CONT SEE SCHEDULE 'Ll" TOP CONT '12" INUORT,11181 INTERMEDIATE BARS B07r. CONT 135 DEG I / jwj MID BARS SEE SCHEDULE TYPICAL CONCRETE BEAM BAR BENDING DIAGRAM BEAM & LINTEL SCHEDULE MARK DIM WXD REINFORCING STIRRUPE REMARKS BOTTOM TOP INTER. SIZE SPACING HOOK TYPE B-1 8xl6 2#5 2 #5 #3 @ 6" OC NOT USED B-2 8X28 2 #7 2 #7 #3 @ 6- OC NOT USED BB-1 8xl6 1 #7 1 #7 - - BB-2 8xl2 2 #5 2#5 L-3 8xl6 Cmu LINTEL 1 #7 1 #7 8x8 PRECAST RATED FOR 900 LBS/FT FOR UP TO 5'-0" 11 L-2 18xl6 PRECAST RATED FOR 1500 LBS/FT FOR OPNG'S 5'-lnTO 12�-_O-� FOOTING SCHEDULE MARK DIMENSIONS WxL DEPTH REINFORCING REMARKS S 7-0" CONT. 12" #5 AT 12" TRANSVERSE 3 - #4 CONT. BOTTOM T.O. FTG EL. 98'-8" TE-1 8" x CONT 81, 2 # 5 CONT TOP 24" x CONT 12" 2 # 5 CONT TOP "4 'L 0 uj 0 Lu __j tn LL 5 2� Lu E Lu I 0 u _lclj 4 . ?3 , -, A m STRUCTURAL WALL SCHEDULE MARK MATERIAL REINFORCING REMARKS W-1 8" CMU # 5 @ 32'OC FULLY GROUT REINFORCED CELLS ONLY. REINFORCED CMU WALL SEE PLAN MARK AND SCHEDULE ON GRADE WWF -SEE PLAN COMPACTED SUBGRADE (4) #5 CONT. EQ SPACED #5 AT 12" OC BOT SECTION AT DIVIDING WALL 3/4"= 11-01, REVIEWED FOR CODE COMPLIANCE 168*1 ST. LUCIE COUNTY,%.% BOCC 0" tu n V) 0 Z W U- I 0 z Lu 57< F5 N 00 01% Iq cv) u De �y CL I — Cie 0 LL_ Lu w z Lu 0 1 *_0 0 01 Lu CL A Lu u 13� Lu rail I-_ Li — ILL. 0 V) L-u F— w Lu CL 0 CL w ui 0 z LLJ _j 9 >n z Tn in V) Lu C) Lu r u V) ur.�toxoyliliv�if SCANNED BY ST LUCIE COUNTY Ppoi 17109 DATE JULY 22, 2019 0111ttowl"'NoRpoll = m_ 10.11are 175 CFM 1 08—C D GFffAT ROOM m 175 CFM 1 0_87D z 0 m. i�_� --(I 0 NEW 11001 8-.0 'I J 150' efFM�-- �55_CFM 1 fX 8—C D 2XII C /'6X6 CD Y 'T__1 A 1AA �XMOV ....... ... . .... .... 0_6 ml Cw FIRST FLOOR PLAN 11411 = 1 1-011 al 11 0 NOTE: TOTAL AC VOLUME PER JN� IS �5,066 CUBIC FEET 175 CFM 1 58—C D ME 175 CFM 1 fX8_CD GKEAT ROOM AIT131 COVERED ENTRY L_R 11 3.0 TON CU-A I DRAWING KEYNOTES Q 4" BATHROOM EXHAUST THRU EAVE WITH INSECT SCREEN AND 6X6 GRILL.. Q RECIRCULATING HOOD 1OXIO SUPPLY JP/DOWN TO SECOND FLOOR. REFRIGERANT LINES ALONG WALL WITH LINE COVER. CONDENSER UNIT SLAB MUST BE THE SAME ELEVATION AS FINISH FLOOR, 12" ABOVE FLOOD ELEVATION PER FMC-SECTION 301.16-2014 AND FBC 1612.4.2014. 6" BATHROOM EXHAUST THRU EAVE WITH INSECT SCREEN AND 8X8 GRILL. (D 4" DRYER EXHAUST THRU WALL WITH BACK DAMPER AND WALL CAP. MINIMUM 26 GAUGE SHEET METAL. DRYER EXHAUST LESS THAN 200 CFM. PROVIDE LOUVER DOOR SECOND FLOOR PLAN 1141, = 1 1-01, SCANNED BY ST LUCIE COUNTY blach. d 11�111jil IN i3d en 5130 N. Federa I Hwy, Suit Ft. Lauderdale, FL 33308 Z No.69753 Tn P: (954) 461-4314 bach@bochengineers.c CA#28826 Viet Bach Nguyen, P.E-.. Florida License #69753 0 . ....... ... .......... ­__......- ....... ........... .. 11111 Iij % CD (D O� C�4 CC) 0� ry (D 'KT I I CO n U __j LLJ U (1� LLJ 3: 111 U In n ry I- LLJ ry n _j 0 H Ld LL < > 0 LL 2:� c/) I Q LLI 0 Z LLJ < n 1 0 n LLJ CL-/ x CL Z_ n rk" < LLJ n < LLJI n 0 Florida-Caribb Ci: Architectu 7 Erwood Plac Boynton Beach, FL (561) 308 669z www.FCArchitectur AA26002566 D5GN DRWN AF`VD FPIOJ DATE JULY 22 DWG M-1 AIR DISTRIBUTION SCHEDULE DIFFUSER TYPE RF M DIFFUSER CFM TAG MANUFACTURER & MODEL NO. NOTES: 4-WAY ADJUSTABLE A TITUS 250-AA OPPOSED BLADE DAMPER ALUMINUM DIFFUSER ALUMINUM RETURN GRILLE REGISTER B TITUS 300/350 NOTES: 1. ALL GRILLS MUST BE APPROVED BY OWNER/ARCHITECT. SEAL JOINT W/ EPDXY & DUCT TAPE AIR FLOW 1� INSULATE TOP OF ALL AIR TERMINALS DIFFUSER AIR DUCT (SEE PLAN MEW) SPIN TAP FITTING 111191=90 AIR FLOW METAL ROUND SCOOP FITTING INSULATED FLEX. DUCT SEAL JOINT WITH EPDXY AND DUCT TAPE NOTE HANG DUCTS ACCORDING TO SMACNA STANDARDS CONDENSER UNIT SLAB MUST BE THE SAME ELEVATION AS FINISH FLOOR, 12" ABOVE FLOOD ELEVATION PER FMC-SECTION 301.16-2017 AND FBC 1612.1.2014. CONDENSING UNIT PROVIDE HC-1 HURRICANE CLIPS PER MANUFACTURE - I I.. 11 17 , , . . . . 1. - . �/ . . NEOPRENE VIBRATION ISOLATORS -------- 4" DIVERSITECH PREFAB PAD PROVIDE 4" PVC SLEEVE AT PENETRATION AND SEAL ENDS WATERTIGHT REFRIGERANT LINES METAL STRAPS SECURED TO BUILDING WALL PROTECTIVE METAL JACKET. PAINT TO MATCH ARCH. NOTE: BOLT CONDENSING UNITS TO CONC, PAD TO WITHSTAND 170 MPH HURRICANE FORCE WINDS PER FBC 301.12. CONDENSING UNIT MOUNTING DET, N. T, S, FAN SCHEDULE MARK SEI ECTION 13ASED ON TYPE/ SERVICE CFM MOTOR D�)IA DRIVE SONES OR NC UNIT WEIGHT MA� E MODEL NO. M 'L WATTS AMP VOLTS-PH-HZ EF-1 PAN NSONIC V_O FV-O 5VK3 BATHROOM 80 4.0 - 120 DRIVE <Q3 12.1 1 GENERAL. FAN NOTES: 3TARTERS, DISDONNECTS AND ALL ASSOCIATED CONTROLS FOR ALL EXHAUST FANS WINGS WITH STRUCTURE, EN ON ALL INLETS AND OUTLETS, iTS 1. PROVIDE MOTOR ON ALL FANS. 2. PROVIDE SACKDRkFT 3. FIELD ADJUST 0 4. PRO 1 5. swil WALL STRUC THERMOSTAT SUPPLY AIR DUCT FLEX -CONNECTION AIR HANDLING UNIT - REFRIGERANT LINES FLOAT SWITCH WIRED TO SHUT DOWN AHU -CONDENSATE DRAIN WITH TRAP (Y SEAL) NEOPRENE PAD AIR HANDLING UNIT SUPPORT ( 1"xl"xl/4" STEEL ANGLE FRAME) TYPICAL VERTICAL AIR UNIT DETAIL NOTE: R7-T-- 1. PROVIDE MINIMUM 4" SERVICE/ MAINTENANCE AREA AROUND AIR HANDLING UNIT. 2. PROVIDE FLOAT SWITCH IN DRAINPAN WIRED TO SHUT DOWN AC UNIT IN CASE OF CONDENSATE STOPPAGE, SPLIT SYSTEM SCHEDULE AIR HANDLING UNIT AIR COOLED CONDENSING UNIT SYSTEM DATA 111RK MODEL ESP FAN HEATER UNIT MAX DIMENSIONS Wr MARK MODEL ELECTRIC L COMPRESSOR FAN UNIT MAX CAPACITY SEER REF. UNES TOTAL _j OA F _TYTT-N­-7Z__ QTY FLA MCA MOOR TM8H SMSH SUCTICN LIQUID NO MCA MOCP MDXH NO. USE VOLTS-PH-HX AHU-A TRA TEM6*OC36 1200 .5 1/2 5.8 1 40 40 23 5X21 X52 150 CL-A TRANE 195 240-1-60 1 3.0 14.1 1 0.93 19 30 35.0 27,0 16.5 3/4 3/8 SPLIT SY51EM NOTES: 1. OUTSIDE AIR DESIGN CONDITIONS: 9ITDB - 79'FDB. 6. MATERIALS: 2. PROVIDE A/C UNITS NTH PROGRAMMABLE HEATING AND COOLING THERMOSTAT NTH ON -OFF SWITCH SUB -BASE. (WRED AND INSTALLED BY ELECTRICAL CONTRACTOR) A. REFRIGERANT PIPING: SHALL BE TYPE L SOFT DRAWN, COPPER TUBING, DEHYDRATED FOR REFRIGERANT USE, SIZED AS SHOWN ON DRAWINGS OR AS 3. PROVIDE PROPER VIBRATION ISOLATORS AS PER ISOLATION PER AIR CONDITIONING EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. MANUFACTURER'S RECOMMENDATIONS. PROVIDE FILTER RACK UNDER B. INSULATION: REFRIGERANT SUCTION PIPING AND CONDENSATE PIPES SHALL BE AHU. INSULATED WITH 3/4" THICK FOAMED PLASTIC INSULATION. FIRE RETARDANT TYPE. 4. INSTALL CHEMICAL DRYER AND STRAINER IN REFRIGERANT LIQUID LINES. INSULATION SHALL BE INSTALLED IN PIPING BEFORE ASSEMBLY. NO SPLIT 5� PROVIDE BUILT-IN DISCONNECT NTH ALL AIR HANDLING UNITS. INSULAI]ON WILL BE ACCEPTABLE. SEAL JOINTS WITH MANUFACTURER'S APPROVED ADHESIVE AND GREY TAPE. -HVAC GINERAL NOTES 1. GENERAL A. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE (MECHANICAL 2017 6TH ED,) AND WITH ALL APPLICABLE REGULATIONS. B. DRAWINGS: REFER TO ALL DRAWINGS FOR COORDINATION OF THE HVAC WORK. C. ARRANGE AND PAY FOR ALL PERMITS LICENSES, INSPECTIONS AND TESTS. OBTAIN THE REQUIRED CERTIFICATES AND PRESENT TO OWNER. D. GUARANTEE: THE COMPLETED INSTALLATION SHALL BE FULLY GUARANTEED AGAINST DEFECTIVE MATERIALS AND/OR IMPROPER WORKMANSHIP FOR A MINIMUM OF ONE YEAR FOR MATERIAL AND LABOR. ALL COMPRESSORS SHALL BE GUARANTEED FOR 5 YEARS MINIMUM. 2. NOTUSED. 3. DESIGN PARAMETERS: A. INDOOR DESIGN TEMPERATURE (SUMMER): 78F DB B. INDOOR DESIGN TEMPERATURE (WINTER): 72F DB 4. ALL THERMOSTATS SHALL HAVE HEATING MODE MAXIMUM SETTING OF 75 F, AND COOLING MODE MINIMUM SETTING OF 70 F. THE THERMOSTAT SHALL BE ARRANGED TO PREVENT THE SIMULTANEOUS OPERATION OF HEATING AND COOLING. 5. ELECTRICAL CONTROLS AND POWER WIRING: UNDER ELECTRICAL CONTRACT. 6. EQUIPMENT SPECIFIED BY MANUFACTURER'S NUMBER SHALL INCLUDE ALL ACCESSORIES, CONTROLS, ETC,, LISTED IN THE CATALOG AS STANDARD WITH THE EQUIPMENT. OPTIONAL OR ADDITIONAL ACCESSORIES SHALL BE FURNISHED AS SPECIFIED. 7, MATERIALS: A. REFRIGERANT PIPING: SHALL BE TYPE L SOFT DRAWN, COPPER TUBING, DEHYDRATED FOR REFRIGERANT USE, SIZED AS SHOWN ON DRAWINGS OR AS PER AIR CONDITIONING EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. B. INSULATION: REFRIGERANT SUCTION PIPING AND CONDENSATE PIPES SHALL BE INSULATED WITH 3/4" THICK FOAMED PLASTC INSULATION, FIRE RETARDANT TYPE. INSULATION SHALL BE INSTALLED IN PIPING BEFORE ASSEMBLY. NO SPLIT INSULATION WILL BE ACCEPTABLE. SEAL JOINTS WITH MANUFACTURER'S APPROVED ADHESIVE AND GREY TAPE, C. DUCTWORK: A. ALL SUPPLY AIR DUCTWORK SHALL BE 1-1/2" THICK FIBERGLASS DUCTBOARD, FABRICATED AND INSTALLED AS PER LATEST EDITION OF SMACNA "FIBROUS GLASS DUCT MANUAL". R-6.0 MIN, B. ALL OUTDOOR AND EXHAUST AIR DUCTWORK SHALL BE GALVANIZED SHEET METAL OR ALUMINUM DUCT NOT LIGHTER THAN 24 CAGE. C. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS. D. FLEXIBLE INSULATED DUCTWORK W17H 1-1/2" THICK FIBERGLASS INSULATION WITH FRK VAPOR BARRIER. R-6.0 MIN. 8. CONTROLS: AIR CONDITIONING UNITS SHALL BE STARTED AND STOPPED THRU INDIVIDUAL PROGRAMMABLE THERMOSTAT. INDIVIDUAL THERMOSTATS SHALL START/STOP FANS AND ACTIVATE COOUNG/HEATING SYSTEMS AS SELECTED. 9. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID ANY INTERFERENCES THAT MAY DELAY PROGRESS OF CONSTRUCTION, CONTRACTOR SHALL INSTALL ALL NECESSARY OFFSETS, BENDS, AND TRANSITIONS REQUIRED TO PROVIDE A COMPLETE SYSTEM AT NO ADDITIONAL COST TO OWNER, 1W CEILING SUPPLY DIFFUSER V-\j CEILING RETURN DIFFUSER PROGRAIVABLE T-STAT. NEW FLEXIBLE DUCT, J.L. CLASS 1 (R-6) NOTF- TYPICAL Z BAR AND WIRE DUCT HANGING DETAIL SECURE WIRE 10"0 MAX. FLEXIBLE DUCT SHALL BE SUPPORT PER FBC M1601,4.4.4 1. HORIZONTAL DUCT SHALL BE SUPPORT AT INTERVALS NOT GREATER THAN 5 FEET 2. DUCT SAG BETWEEN SUPPORT SHALL NOT BE EXCEED 1/2" PER FOOT OF LENGTH 3. DUCT STRIP SHALL BE DiVERSITECH DUCT 1-3/4" POLYPROPYLENE HANGER STRAP OR EQUAL. METHODS OF HANGING DUCTS DETAIL N T.S� bach.( en 5130 N. Federal Hwy, Suit Ft. Lauderdale, FL 33308 P: (954) 461-4314 bach@bachengineers.c CA#28826 Viet Bach Nguyen, P.E. Florida License #69753 0 SCANNED BY LUCIE COUNTY No. 89753 (D (D 16 0 011 00 2 V) 0� a� ,-I- LU cy) In -7 1 < LL F I U L LLJ C U-i U r 0:� Lu LLJ U < ry III Li n _j 0 Lj_ Li - I I < > 0 LL C/) u I U 0 z LU < 0_ _j 0 LU rv, x < Z cl,� LU < Q I < LLJ z x LLJ I L! C) 0 Florida-Caribbeai A ArchitecturE 7 Erwood Place Boynton Beach, FL 334 (561) 308 6694 www.FCArchitecture.c( AA26002566 D5GN DIRWIN APVD FIF10i 171 DATE JULY 22, 2C DWG M-2 GREAT ROOM FA 1-0-31 COVEFIED ENTKY AM m romi Mani I Ew =11-OWL1111 GARAGE Et-0-2 I I I r <�ITCHEN KS.I I All 4 5 GARAGE FA-1-1-21 .. ... ... . . .. ... .... ... ... ... ... ... .... ... ... ... .. ... .... . .. .... .... . .. .. . m FIRST FLOOR PLUMBING E 11411 = I'-0" H B -(2 GREAT R'00m FAT 173 COVERED F- N T R.Y LXj ......... 11 Uji PLUMBING KEY NOTES TIE NEW 4" SANITARY TO EXISTING. CONTRACTOR TO FIELD VERIFY EXACT LOCATION. (D TIE NEW 1" CW TO EXISTING. CONTRACTOR TO FIELD VERIFY EXACT LOCATION. 50 GALLON LOWBOY WATER HEATER (4.5 KW @240 V) 0 3" SANITARY UP TO SECOND FLOOR 1/2" HW AND CW UP TO SECOND FLOOR 1/2" HW AND 3/4" CW UP TO SECOND FLOOR 1/2" SW UP TO SECOND FLOOR 3" SANITARY DOWN @ 1/2" HW AND 3/4" CW DOWN TO FLOOR 1/2" CW DOWN TO FLOOR 1/2" CW DOWN TO FLOOR SECOND FLOOR PLUMBING PLAN 1/4'' = 1'-0'' bach.d. en 5130 N. Federal Hwy, Suit k: Ft. Lauderdale, FL 33308 Z P: (954) 461-4314 bach@bachengineers.c —W CA#28826 Viet Bach Nguyen, P.E. Florida License #69753 SCANNED BY ST LUCIE COUNTY U-1 n CD 0 16 0 cl� 00 V) 0� rlp� ,,I- Lu CO r) Z -i ILL U LJJ Eli U U In cL lc::f q� CL 0 1--: LL LL Lu- LL- < > 0 z H (,0 < LU —i 0 n 0 Q�� Z LLJ 0 0 0 j2 LIJ 12:� I x EL U- z a� (-D < LLJ z CIO Z X Lij 0 CL Florida-Caribbea,n Architecture 7 Erwood Place Boynton Beach, FL 33426 (561) 308 6694 www.FCArchitecture.corr AA26002566 D5GN DRWN Af'VD FPOJ 17109 DATE JULY 22, 20 19 DWG P-1 W P2903.4 THERMAL EXPANSION CONTROL. A MEANS FOR CONTROLLING INCREASED PRESSURE CAUSED BY THERv1AL EXPANSION SHALL BE INSTALLED WHERE REQUIRED IN ACCCRDANCE WITH SECTIONS P2903.4.1 AND P2903.4.2. P290 .4.2 BACKFLOW PREVENTION DEVICE OR CHECK VALVE. WHERE A BACKFLOW PREVENTION DEVICE, CHECK VALVE OR OTHER DEVICE IS INSTALLED ON A WATER SUPPLY SYSTEM USING STORAGE WATER HEATING EQUIPMENT SUCH THAT THERMAL EXPANSION CAUSES AN INCREASE IN PRESSURE, A DEVICE FOR CONTROLLING PRESSURE SHALL BE INSTALLED. 2-WAY, CLEAN -OUT WALL CLEANOUT DETAIL TYPICAL UNIT SANITARY PIPING ISOMETR4C I <WG WM �/q' 04 WG IP Tu� LAI > rl �w HW I NOT[: 1. ALL FIXTURES SHALL COMPLY WITH TABLE 604.4 OF THE F.P.C. 2. ALL WALL HUNG PLUMBING FIXTURES SHALL COMPLY W/ FBC 2318.1.15 OR 2517.5.1.1 3. ALL SHOWER VALVES SHALL COMPLY WITH 424.3 OF THE FP.C. TYPICAL UNITWATER PIPING ISOMETRIC NO SCALE 5H� FACE OF WALL STAINLESS STEEL COVER SCREWED TO THREADED C.0, PLUG. PLUMBING SYMBOL LEGEND SYMBOL DESCRIPTION SANITARY LINE VENT LINE SAFEWASTE LINE CD CONDENSATE LINE GATE VALVE COLD WATER LINE HOT WATER LINE p- PLUMBING FIXTURE DESIGNATION FCO FLUSH CLEAN OUT tTl FLOOR PENETRATION AIR CHAMBER WOO WALL CLEANOUT VTR VENT THRU ROOF COOG CLEANOUT ON GRADE HB HOSE BIBB W/VB PLUMBING FIXTURE SCHEDULE NAME FIXTUR MODEL# NO WATER CLOSET BYOWNER (TANK) LAV DROP -IN BY OWNER LAVATORY TUB TUB/SHOWER BY OWNER KS KITCHEN SINK BY OWNER WIM WASHER SUPPLY OATEY WASH BOX BOX ALL TUB AND SHOWER VALVE SHALL BE ANTI -SCALD AND SHALL COMPLY WITH ASSE 1016. FIXTURE WATER PIPE SIZ NOMINAL SAN. IZE MAXIMUM FLOW RATES WATER CLOSET (TANK) 1/2' 3" 1.28 GPIF LAVATORY 1/2' 1 1/4' .5 GPM TUB 1/2" 2" 2.5 GPM * ALL PLUMBING FIXTURES SHALL BE SELECTED BY AND INSTALL BY CONTRACTOR THERMAL EXPANSION T 3/4" HEAT TRAP HOT WATER TO SYSTEM, P & T RELIEF VALVE. ELECTRIC WATER HEATER DRAIN VALVE � �— COLD WATER SUPPLY '--SHUT-OFF VALVE HEAT TRAP WATER SUPPLY TO HEATER. P & T RELIEF LINE FULL SIZE 3/4" PR LINE TO DRAIN PAN FLOOR tjILLI-L . . . . . . 30x3Ox3 GALVANIZED DRAINPAN OF LINE TO OUTSIDE, T M ERMINATE POINTING DOWN 6" ABOVEGRADE, TYPICAL WATER HEATER D -TAIL NO SCALE HANDLE- 3/4' HOSE THREAD-� GENERAL PLUMBING NOTES: 1. A. ALL WORK SHALL BE DONE IN ACCORDANCE NTH THE FBC (PLUMBING 2017 6TH ED.) AND WITH ALL APPLICABLE REGULATIONS, B. DRAWINGS: REFER TO ALL DRAWINGS FOR COORDINATION OF THE PLUMBING WORK. C. ARRANGE AND PAY FOR ALL PERMITS, LICENSES, INSPECTIONS AND TESTS. OBTAIN THE REQUIRED CERTIFICATES AND PRESENT TO OWNER. D. GUARANTEE: THE COMPLETED INSTALLATION SHALL BE FULLY GUARANTEED AGAINST DEFECTIVE MATERIALS AND/OR IMPROPER WORKMANSHIP FOR A MINIMUM OF ONE YEAR FOR MATERIAL AND LABOR. E, ALL HORIZONTAL SANITARY PIPING SHALL SLOPE AT 1/8 INCH PER FOOT MINIMUM FOR 3" AND LARGER AND AT 1/4" SLOPE FOR 2" PIPES AND SMALLER. 2. NOT USED, 3. PLUMBING FIXTURES: FIXTURES SHALL BE AS SELECTED BY OWNER AND SHALL BE FURNISHED AND INSTALLED BY THIS CONTRACTOR. FIXTURES SHALL BE COMPLETE WITH DRAINS, TRAPS, SUPPLIES AND ANY OTHER ACCESSORY REQUIRED. FIXTURES AND FAUCETS SHALL COMPLY WITH THE FBC WATER SAVING STANDARDS, 4. MATERIALS: A. PIPING: A. STORM, SOIL, WASTE AND VENT: SANITARY PIPE, PVC, DWV, SCHEDULE 40. B. DOMESTIC WATER� COPPER PIPE, TYPE L WITH SWEAT WROUGHT COPPER FITTINGS. TYPE "M" IN CONCEALED SPACES IS ACCEPTABLE FLOW GUARD CPVC AND PEX PIPING IS AN ACCEPTABLE SUBSTITUTION ISOLATE PIPING FROM CONCRETE WITH INSULATING MATERIAL. C. DOMESTIC WATER SUPPLY ASSEMBLY: STAINLESS STEEL BRAIDED SUPPLY LINE WITH ANGLE SHUT OFF VALVES. D. INSULATION: INSULATE ALL HOT WATER AND HOT RETURN WITH 1" FIBERGLASS INSULATION. 5� ALL AUTOMATIC ELECTRIC WATER HEATERS SHALL MEET THE STANDARDS OF THE LATEST ENERGY EFFICIENCY CODE. 6. PIPING TEST AND DISNFECTONS: A. TEST: ALL SANITARY AND DOMESTIC WATER SUPPLY PIPING SHALL BE TESTED FOR LEAKS BEFORE PIPING IS CONCEALED OR CONNECTED TO EQUIPMENT AND PLUMBING FIXTURES. B. DISINFECTION: ALL DOMESTIC WATER PIPING SHALL BE DISINFECTED BY INTRODUCING A SOLUTION OF CALCIUM HYPOCHLORITE OF 50 PARTS PER MILLION OF CHLORIDE AND AS PER AWWA STANDARDS, 7. HOSE BOBS: SHALL BE 1/2 INCH, ROUGH BRASS CONSTRUCTION NTH SHUT OFF VALVE AND VACUUM BREAKER, & ALL OUTDOORS FLOOR CLEAN OUTS SHALL BE TERMINATED UP TO GRADE AND SHALL BE MARKED, 9. CONTRACTOR SHALL COORDINATE EXACT LOCATION OF SANITARY, AND DOMESTIC WATER PIPING BEFORE STARTING ANY WORK, NOTIFY ARCHITECT/ENGINEER OF ANY DEVIATIONS FROM DESIGN DRAWINGS. 3/4' CONNECTION SS FLANGE WHERE TACHED TO EXPOSED PIPING JGH CHROME PLATED - VACUUM BREAKER (VANDAL PROOF) HOSE BIBB DETAIL SCANNED BY ST LUCIE COUNTY ba h.d % NG.0 le 5130 N. FederaJ Hwy, Suit Ft. Lauderdale, FL 33308 No. 697 P: (954) 461-4314 bach@bochengineers.c PROJ 17109 CA#28826 OF DATE JULY 22, 20 15 Viet Bach Nguyen, P.E Florida License 469753 DWG U-i ( In CD CD I �O CD 0", C�4 00 0- Cz t LLI 0 C") Z LLI I U LJJ I Uj U I _j 11� LU LLJ U a- ry Ly F­ uj n >_ Cz 0 LL_ LI_ < L-Ld LL < 0 ui H ry I n Lu ILL! I-_ C/) 0 0 6�� Q�� LLJ n Lu 0 z Z LIj < z i Lli Z co < X LU 0' Florida -Caribbean F Architecture 7 Erwood Place Boynton Beach, FIL 33426 (561) 308 6694 www.FCArchitecture.com AA26002566 D5GN DRWN AFVD RE, 20 13. ALL RIGI-IT5 FZI!5E�VrID DOSTING FPL POLE 6" WM - - - eITE W01R< WILL BE COMFLETEF,) OVERHEAD eEF,4f;R,4TEL�r UN::)EFR f=ERMIT ELECTRIC LINE f a0i:5�- -0-2-1,9, - D-R, 4-W. INC3 - 15- -1 N-C L UL)fz) --- ----------------------------------- ------------- f=0fR REFERENCE ONL�r. �' ",;-- - � 0 U ---- ------------- 3 7 1 2 �*2/0(Al VC VC 1-111 VIC (CIA 3 4n2 /0 1-2111`0 11 E -2"FDV( -3:: F;iv f0v 12 SEI 2-21W A 2 11 a 2-111 3 8 L 3 (A �V 211 1_� C PVC L OF=HONE (EATV) 2 0.9 b8 cis 1,0 1,2 1.3 1.3 2L2: 1.4 1.6 1.7 2. '1.7 'Is *1. 8 '2.2 �A �s '2.3 �.s '2.2 �.2 �.6 1 -Va 16 �.5 �.o 1 3 3 4.6 SA �s �.s .7 MH: 20 49 3.0 �.6 .0 '4.2 '2.7 13.4 3.6 '3.1 '2.4 �.i 2,2 2.2 2.7 2.9 A '2.7 2.3 3 S- t 2.2 T '2. 0 '2.1 '23 '2. 2 z / *2.2 '2.1 110 P T bq -1.5 '17 t.8 18 9 1.5 7 '1.8 18 �T T; : -1.7 'is �.o - I __log 1. I 119 :2.0 2A 1 *2 A *2, z '23 �ff`WR) '1 '2.3 '2.4 28 2 '2.2 24 Ys 1.7 3 5 24 3.2 ES- 7 �o '2A '3.4 .9 3 4.1 '3.3 '3.3 + 3.2 29 �o L 12 24 '2.6 '3, -1.7 '2.2 '2. 5 '3 1.8 23 2.5 2 \ F *I. a '2.1 2 3 5 'i 5 'is '2 0 2 '12 111.4 i's 4 4 9 I T t- I Q,/AL. �S-2 FH WM ------------ Ig 1 --7-j 771 . -Ali I J F77--`D 1- 77 0.0 0.0 0.0 0C.P <WO 0 0.0 U.0 U-:3 U..i U.:5 U.1 u.0 U.0 U.0 4 ll Luminalre�e � u Sy m-- b all Label Arrangement Lum. Lumens LLF fatts 2 SA SINGLE 10087 0.900 113 113 Calculation Summary Label -FCalcType Avg Max Min Avg/Min Max/Min PROPERTY LINE1 - - - - - - - ffilurnInance Fc 0.09 0.4 0.0 N.A. N.A. Pkbpuffy LINE 2 -6ju-minance FF-c-0.0-7 --0.3 10.0 N A. N.A. SITE I Illuminance Fc 2.33 4.9 0.8 2..;l 16.13 N 1 SITE PLAN 7 � / I G` = 1 1-011 il 15, 20 19 - 08:50PM FlUFNAME: E5 1 -E52,dWCj 1 4 S�TS r 'Z '3 1 34!� 94VC)(F"WR) 4-111 Mvc E - 0=14 4- c A T ',Vv') J 3 E X 6" TYP. 3/4" STAINLESS STEEL U-BOLT PLAN "A" STAINLESS STEEL CHANNEL ELEVATION STAINLESS STEEL CHANNEL 1 OOA 0 METER PANEL 'H' TIC 22kAICJ (g) GFI/ WP RCIPT PVC-RGS COUPLING, L-2-0 TYP. RGS PLAN "A"\- STAINLESS STEEL U-BOLT CONDUIT, TYP. GRADE GND PVC CLAMP /111-ClONDUIT TYP. TYP. - .4 36" . ... ....... 2"C TO CONDUITS AS FPL REQUIRED 1 24" 4MOUNTING RACK FOR SITE POWER SCALE. NONE (EXTERIOR) 120/24OV, 3 NEMA 3R PNL H W10/'ffY 100 %SS NE IMA 3R rHouse 1 2 !0/240V 10,3W FMCB MTR 50A DRILL & BOLT ELECTRICAL EQUIPMENT TO RACK WITH STAINLESS STEEL Fr. L F C-1 -1 ELECTRICAL DESIGNATIONS COMPONENTS, TYPICAL SYMBOL DESCRIPTION STAINLESS STEEL CHANNEL JA TYPE 316) TYPICAL, 0 D RECESSED CANLIGHT FIXTURE NTH INSULATED CASE HOUSING 28TAM 1 5/8" CHANNEL WITH 9/16- DIA. HOLES SPACED WALL MOUNTED LIGHT FIXTURE 1 7/8" O.C. FAN OR MOTOR - NUMERAL INDICATES HORSEPOWER 4" DIA. CONIC. FILLED STAINLESS STEEL SUPPORT POST, TYPICAL POLE MOUNTED L.E.D. FIXTURE FOR SITE LIGHTING CONTROLLED 13Y TIME CLOCK, SEE SHEET ES-2 FOR FIXTURE TYPE. ELECTRICAL MECHANICAL EQUIPMENT 3000 PSI CONCRETE. RACK SHALL SHARE SAME PAD AS MAILBOX. COORDINATE ------ HOMERUN - ONE ARROW PER CIRCUIT DUPLEX RECEPTACLE - GROUND FAULT INTERRUPTER WITH ARCHITECT. t4 BARE 0 PIPER FLI TRANSFORMER EXOTHERMIC WELD METER Ewa ------ - ---- PANELBOARD (PNQ 3/4- X 10' GROUND ROD FP-1 PULLSOX NF-NONFUSED, 60--LFRAME SIZE) DISCONNECT SWTCH (SIZE INLOTED; L2-INO. fOFPOLLES, Lj 2y& E::p 1#8 GND(CU) IN l*C TO SITE #4 CU GEC p LIGHTING c �­ -4#8(CU), BLDG STEEL 1#8 GND(CU) IN 1"C TO IRR. PUMP STN ... -- -, ---- '­ I WID STEEL CW CONC., ENCASED ELECTRODE. 3#6 (AL) & GROUNDING ELECTRODES PER NEC 250.52 IN 2"C TO FPL 4. X 1( 2-3/4" X 10- CU RODS, 6 Fr APART 3M ELECTRICAL RISER FOR SITE POWER I SCALE: NONE 3#1/0 - 2"C 3#1 /0 2 200A, 2 NEMA 3R, DISCONNECT MAIN DISC. 1OkAIC 200A. NEMA 3R, FPL METER W/BYPASS 2" RGS CONDUIT TO WEATHERHEAD NEMA 3R METER CAN WITH BYPASS FOR FPL TRANSFORMER WOOD POWER POLE NEMA 3R GENERAL DUTY FUSIBLE SERVICE DISC. LOAD CALCULATIONS it) TRAILER 0 100% (20.0 X 1.00) 20.0 ItVA (EXTERIOR) 3#1 #BG #8G TOTAL 20,0 <VA /0 => 96.OA 0208V, 10 1 1/2% GRADE TO CONSTRUCTION To- NOTEe TRAILER FASTEN DEVICES AND CONDUITS IN CONSTRUCTION TRAILER ACCORDANCE W/NEC REQUIREMENTS. 5/8" x S' C.U. GND. ROD, USE STAINLESS STEEL COMPONENTS 2, TEMPORARY ELECTRICAL RISER SCALE: NONE ELECTRICAL PANEL SCHEDULE a SCALE: NONE MISCELLANEOUS DESIGNATIONS SCEL LA N EO US DES NA T'ONS L '- G OL LTG CONTROL ONT R ABBREVIATIONS RE A a B 10 VI T - 0 C NTACTOR CONTACT .. OR: �FF _ ABO FIN S VE I H FLOOR AFF - ABOVE FINISH FLOOR 3 Pole ' 240V with I 20V '.'I 3 Pole, 240V, 30A with 120V coil in LT INTERRUPT GFI - GROUND FAULT INTERRUPT GFI _ GROUND FAU ]TE !fN �30A N E MA 3R en I'su. NEMA 3R enclosure NIF - NON -FUSED NIF _ NON FUSED PNL - PANEL PNL PA EL TIMERS TIMERS TV CAB LE LE TE VISION TV - CABLE TELEVISION GR NO - UG - UNDER GROUND UG UNDER OU T I M E C L K 240v 4 A D 9T TIME CLOCK 240V, 40A, IDPST OC P' 0 \A F VERI F IN FIELD VIF - VERIFY IN FIELD Y 1 Hardwired, Programmable, w/ Battery H rd d P a ' be w/ Battery , w" Pgr , WIP - WEATHERPROOF WEA HER R F WP T P 00 Backup and Rain Sensor Shutoff when Back. P and R.,n,5e",r Sh.tff when UNO UNLESS NOTED OTHERWISE u N 0 U NLESS N OTED OTHERW SE used for irrigation used for rngat", VLOJ VER I IFY LOCATION ON JOBSI a VLOJ VERIFY LOCATION ON JOBSITE. CzENERAL NOTEe: I COORDINATE INSTALLATION OF TRANSFORMER F"ADS AND F"RIMARY SERVICE CONDUITS WITH FFL SERVICE f=LANNr=R MYKHAILO KORIN (112) 331-1025. 2. COORDINATE INSTALLATION OF TELEPHONE SERVICE CONDUITS AND COMUNICATION HANDHOLE W1 AT4T ENGINEER. 3. FF"L PRIMARY SERVICES TO BE PROVIDED, INSTALLED, AND FAID FOR BY FI=L AND/OR OWNER. =R F"ADS PROVIDED, INSTALLED, 4. ROL TRAN6FORMr AND PAID FOR BY FI=L AND/OIR OWNER, 5. ALL SECONDARr SERVICES TO BE DIRECT BURIED. <EY NOTEe: FFL METIER UNIT PANEL. (D F"ANEL 'H'. IRRIGATION FUMF` STATIC FFDL METER/MAIN COMBO. IOOkVA Ff=L XFMR.SEE DETAIL I ON SHEET E5-2 6, NOTES SCALE. NONE FAULT CURRENT CALICS AIC FOR 167kVA (WORST CASE): 53,205A SYM PER FIPL Cvalue 1 SET, 6(AL) = 1,482 f = 2.OxBO'x53.205 = 23.9 1,482 x 240 1 M= .040 1+f 53,205 x .040 2,134 A.I.C. AT METER. SERVICE CALCUALTIONS PER NEC TABLE 220: PANEL 'H'.' LTG 0 125% (240 X 1.25) = 30OW EQUIP 0 100% (4,700 X 1.0) = 4,70OW ESTIMATED DEMAND 5,OOOW => 20.8A, 1 0 VOLTAGE DROP CALCS: (LOAD 216) (PNL 'H' HAS 1 SET OF #6(AL) RATED 50A) DISTANCE x OHMS/KFT x LOAD = VOLTS - LN 8OFT x .808/100OFT x 21 A = 1.36V - LN 1.36V - LN x 2.0 (1PH) 2.72V - LL 2,72V - LL 240V = .0113 .0113 x 100 1.13% VDROP Q < 0 CD -16 (D C�- 1� 00 ]�i V) 0� "'t LU (y) [L -j LL I U U3 LU o -j 0�1- LU 3� U-j LU 0 LL LL LLi LL < > 0 U- V) 0 z 0 < Z LU -.1 o- < 0- 0 LU V) z X -j C) < < LU U Uj z 5<- I < LLJ U - 0 LLJ LU Florida -Caribbean "ni F 01 Architecture SCANNED 7 Erwood Place 5. CALCULATIONS BY Boynton Beach, FL 33426 (561) 308 6694 SCALE: NONE ST LUCIE COUNTY www.FCArchitecture.com AA26002566 Pie \Ir-Flill D5GN D. PETERKIN IN o. 75M DFWN D. I"IfTEPKIN IPIDC INC jj:z APVC) D. FfTEPKIN 5707 S. Dixie Hwy, #8 0 STATE OF West Palm Beach, � PROI 17109 _, �;o Florida 33405 DATE JULY 22, 2019 Phone: 561 436 9 11 Fax: 561 493 1560 Deveren Peterkin DWG ES-1 Cert. of Auth.: #8800 License #75256 �APIR14�Akf APrH17F�l IP� On I � Al I Pl�"�� PP��P\/Prl INSERT, TYPICAL GRADE SEE DETAIL "A" . ...... ................................ 00 00 14", 60 14 TRANSFORMER PAD C,4 00000 0 0 0000 CY) 0000 16� 6" PLAN VIEW F —FIBERGLASS COMPOSITE FIBERGLASS COVER COMPOSITE FLOOR FIBERGLASS COMPOSITE PULL BOX 6" BED OF PEAROCK OR CRUSHED STONE FOR DRAINAGE. ;E NOTED. WIRED '\ DETAIL SCALE: NONE 51TE WOFK WILL 5E GC�If=LETEr�) 5EFARATEL�T' UNrDER FERMIT *1100a-021e, DRAWING 15 INCLUDED FOR ]REFERENCE ONL�T. � �, -I/- ELECTRICAL SITE EQUIPMENT DETAILS SCALE. NONE )T DATIF: Jul 15. 20 � 9 - 05:50PM FILENAMff: ff5 1 -ff52.clxj i i i T-1 Fi ­1 -1 n I 10'-0" MIN 09 :2 END PLUGS 0 FINISH GRADE i 101-011 MIN F.P.L. CONDUIT 35" RADIUS PROFILE VIEW ' TRANSFORMER PAD �E SCALE: NONE FINISHED GRADE 2 (D n CONCRETE ENCASED WARNING TAPE ELECTRICAL SERVICE CONDUIT & FEEDERS TO FPL RISER POLE, SEE ELEC. SITE PLAN FOR QUANTITY. 3"CONDUIT W/PULLSTRING TO BELLSO. RISER POLE, TYPICAL. SEE ELEC. SITE PLAN FOR QUANTITY WARNING TAPE FINISHED GRADE ......... . ........ -IT C14 COMPACTED ELECTRICAL SERVICE EARTH 12' (0 CONDUIT & FEEDERS BACKIFILL to TO FPIL RISER POLE, SEE ELEC. SITE PLAN YCONDUIT FOR QUANTITY. W/PULLSTRING TO BELLSO. Tvr�lr,Aj RISER POLE, TYPICAJipA2,___f SEE ELEC. SITE PLAN FOR QUANTITY DIRECT BURIED (7� DUCT BANK DETAIL 11�i_� SCALE: NONE REMOVABLE TRAFFIC BARRIERS, TYPICAL, SEE DETAIL 'B' END PLUGS CUSTOMER CONDUITS SIDE VIEW 3000 PSI CONCRETE ,U vr-r-, FRONT VIEW DE 2" CLEAR, TYP. IDE 2" CLEAR OF WELDED C, TYP. #4 REINFORCING BARS 3 1/2" ABOVE GROUND CONCRETE PULL BOX 6" BED OF PEAROCK OR CRUSHED STONE 1-8" FOR DRAINAGE. PVC CONDUIT, SCHEDULE 40 6" C QUANTITIES AND SIZES S NECESSARY PVC CONDUIT, SCHEDULE 40 QUANTITIES AND SIZES EXOTHERMIC WELD AS NECESSARY GROUND ROD 3/4"DIA X 10'-0" NOTE: PROVIDE PULLBOXES WHERE REQUIRED BY N.E.C. TO PREVENT EXCESSIVE LENGTH OF CONDUIT RUNS. IF THE DIMENSIONS FOR THE PULLBOXES ABOVE ARE NOT USED THEN THE BOXES SHALL BE SIZED PER N.E.C. (PULLBOX DETAIL 0 SCALE: NONE DETAIL p) B P) WELD RODS TO TENON ON ALL SIDES #6 GROUND WIRE 29' CA CONCRETE POLE ----------- W/TENON. POLE AND FIXTURES SHALL WITHSTAND 170 MPH WIND LOADING. NOTE: 1). POLE MANUFACTURER TO EVALUATE EXISTING SOIL CONDITIONS PRIOR TO DESIGNING POLE. 2). THE POLE MOUNTED FIXTURE ASSEMBLIES SHALL BE CAPABLE OF WITHSTANDING WINDLOADS ASSOCIATED WITH 170 MPH WINDS BASED ON THE 20'-0" CALCULATIONS USINGS THE FORMULAS AND TABLES PRESENTED IN A581 AND IN COMPLIANCE WITH THE FLORIDA BLDG CODE. PULL BOX BROOKS PROD. 36 SERIES W/ TRAFFIC COVER. (ENCLOSURE FOR PVC BOX). SEE DETAIL "4" ON THIS SHEET. FINISHED GRADE WP. IN —LINE FUSEHOLDER BUSS #HEB—AY (10A FUSE).� CONDUIT AND CONDUCTORS AS INDICATED ON PLANS. 3/4" X 10' — 0" GIND ROD (MAX 25 OHM RESISTAIN 3/4" PVC CONDUIT ENTIRE LENGTH OF POST ABOVE GROUND SHALL BE PAINTED YELLOW (TREAT GALV. PIPE BEFORE PAINTING). PAINT PIPE WITH ONE COAT OF GALVANIZED IRON PRIMER AT 1.5 MILS DRY FILM THICKNESS AND THEN TWO COATS OF HIGH BOND EPDXY PAINT (YELLOW) AT 2 MILS DRY FILM THICKNESS PER COAT. "MCGRAW—EDISON LTG" "GLEON—AF-02—LED—El—SL2— HSS—BZ / MA 1036" 113W LED LUMINAIRE WITH TYPE 2 DISTRIBUTION WITH SPILL CONTROL. SLIP FITTER W/FOUR RECESSED SET SCREWS FOR 2" PIPE TENON. 2" PIPE TENON (2 3/8" O.D.). 3" x 5" MIN HANDHOLE 24" ABOVE GRADE. oil 2— #10CU. FOR —#1 OG SINGLE HEAD AND 1 RUN IN POLE UP TO FIXTURES. POLE MOUNTING DETAIL (TYPE 1B SCALE: NONE SCANNED BY ST LUCIE COUNT' 011111111111J.", A% ...... .75M IZDCE, INC. 5707 S. Dixie Hwy, #8 STATE OF West Palm Beach, Florida 33405 Phone: 561 436 9198 AL �8*0l Fa x: 561 493 1560 Deveren Peterkin Cert. of Auth.: #8800 License #75256 1 ,z, 6z TYPICAL SWITCH & RCPT MOUNTING NOT TO SCALE ELECTRICAL DESIGNATIONS J-1 TON Ill kid: 2 PLOT DATE; Jul 15 g7 6 EA-1 1% Ill (F4 [_JA- 2 1/2- MIN. MIRROR SWITCH GFCI . ..... ... . . . . . . . . . . . . . . . . . . . . . . . .............. -PTACLE MAX. 4'-0 "* 31_8.� Go GFCI +52" 3 3 RECEPTACLE-90 5-10 -10 IF COUNTEF! is 0 LESS TH�N DEE�� 3 -V06 ACC SIBLE_________1 0 LAVATORY I r It ACCESSIBLE 7 KITCHEN BATHROOM RECEPTACLE 41TA111 /E CE3 A- 5-9 H E5 I 5-S E I NF E \3 2 :1 011 30 S - 34 36 60 H H; +6 5-10. A-14 15-14 GREAT P"COOM A-121 I I I I I �vl ET, �+56" +56" 2 2 3 D7 EA - cj EA-1B E5 2� 2 EA -I E5-11 (5-1 In3 3 (0_� A A A-B \E1 D/ 15-a A-0 5-a A-14 5.14 A (D5 A-14 D5,4-& 5-ro 5-14 ........... . ......... . .... . ...... :7 10 5-0 10 GAR,/\Gl� +36" +36" �c E PT r) WP A 1=0 2 WP CIOVFRZ� Ei,17',Y +36" +36" +36" F A-& ---nQ EA - 5 E5-5 l� 5-10 36' \-E PNL PNL EA EB (N PNL B A A 8 \6, 00 FIRST FLOOR ELECTRICAL PLAN 1/411 = � 1-011 � C1 WJ 'Em- �2 CU 3 . I /TV/DATA GIF I EPTACLE BASEMENT, PLASMA TV LAUNDRY, LOCATIONS UTILITY ROOM <EY NOTE,5: FFL METER / MAIN COM50. D.P.S.T. 30A SWITCH. I PANEL 'A. AT +12" FOR HOOD. INATTIC. COORDINATE LOCATION UJITH MECHANICAL. 501b. RATED J-50X IN CEILING. IN CEILING. UP TO LIGHT8,45OVE. DOOR 5ELL IBUTTON. DOOR 5ELL CHIME. 30A MANUAL TRANSFER SWITCH. PANEL 'E'. SYMBOL DESCRIPTION 0 12" SQ. FLUORESCENT FIXTURE W/ ACRYLIC LENS (2-17W LAMPS). 1 X 4 FLUORESCENT FIXTURE W/LENSE (2-32W LAMPS) UNO S 1 7W U No AMP S)' 0 D RECESSED CANUGHT FIXTURE NTH INSULATED CASE HOUSING F,�t'- H�o WALL MOUNTED LIGHT FIXTURE OVID RECESSED VAPORPROOF FIXTURE NTH INSULATED CASE HOUSING - — ----- - --------- ­ ------- ­­ — ---------------- l­__0___­l UNDERCABINET LIGHT WITH LENS. COMBO EXIT/EMERG. AND EXIT LIGHT FIXTURE W/ BATTERY BACK UP EMERGENCY LIGHT FIXTURE W/ BATTERY BACK UP AIMABLE FLOOD LAMP W/ SECURITY AND DAYUGHT SENSOR CONNECTED TO TIME CLOCK, TYP. CEILING FAN: 52' FOUR BLADE FAN W/ VARIABLE SPEED CONTROLS AND LIGHT MOUNT KIT OPTIONAL. DUPLEX GFI RECEPTACLE AND LIGHT W/PULLCHAIN SWITCH IN A171C SWITCHES AND CONTROL DEVICES SYMBOL ........................................................ .......................... .......... DECRIPTION $ SINGLE POLE SWITCH % $4 $0 3 WAY SWITCH 4 WAY SWITCH .............. __ ........... ........... .............. DIMMER CONTROL SWITCH — DIMMER W/ MEMORY RECALL (DM) $FD SWITCH W/ FAN DELAY, ADJUSTABLE 5-60 MIN. $4 $v MOTOR RATED DISCONNECT SWITCH VOLUME CONTROL (SPEAKER SYSTEM) 8 . . ":;I DOOR BUZZER. PUSH BUTTON, 42- MOUNTNG HEIGHT, U.N.O. . . . ............................................. DOOR CHIME, 96- MOUNTING HEIGHT, U.N.O. PUSH BUTTON ACTIVATOR, MOUNTING HEIGHT +48" A.F.F., U.N.O. — — — — - - -------- ------ RECEPTACll AND OUTLETS gym DECRIPTION SIMPLEX RECEPTACLE - 15" A.F.F., U.N.O. DUPLEX RECEPTACLE - 18- A.F.F., U.N.O. WP . . .. . ........... ___ . ................ DUPLEX RECEPTACLE - WEATHERPROOF (WP) DUPLEX RECEPTACLE - GROUND FAULT INTERRUPTER ... ......... DUPLEX RECEPTACLE SWITCHED - LOWER OR BOTH SWITCHED . =0 . ........ -1-1- 11 . . . . ..... I ........ ............. QUAD RECEPTACLE (TWO DUPLEXES) i SP ECIAL PURPOSE RECEPTACLE 3 WIRE W/GND VERIFY W/EQPT.. WALL MOUNTED TELEPHONE/DATA OUTLET - 18- A.F.F., U.N.O. DUPLEX RECEPTACLE & TELEPHONE JACK IN FLOOR BOX, FLUSH MTD -E CABLE TELEVISION - 18" A.F.F., U.N.O. CIRCUITS ALL CIRUITS NEW, UNLESS NOTES 'ETR - -- - ----------- — - ----- — ----- - -- - -----­-­--- HOMERUN - ONE ARROW PER CIRCUIT .... ...... --------- RACEWAY CONCEALED ABOVE CEILING OR IN WALL ELECTRICAL MECHANICAL EauipMENT PANELBOARD (PNL) JUNC71ON BOX - FAN (F), TIMER (T), BLANK (B) COMBINATON DISCONNECT STARTER (OR CONTACTOR) '1 [::HLDIS�CONNECT (SIZE 2-NO. OF POLES, W2Y6 NF-NONFUSED, 60-FRAME SIZE) LSN�TCH LNOTED; FAN OR MOTOR - NUMERAL INDICATES HORSEPOWER MISCELLANEOUS DESIGNATIONS FIRE SMOKE SENSORS ABBREVIATIONS COMBINATION SMOKE ACT - ABOVE COUNTER TOP ALARM/CARBON MONOXIDE ZA ACU - AIR CONDENSING UNIT DETECTOR: AFF ABOVE FINISH FLOOR 120V, Hardwired, Single Station, w/ AHU AIR HANDLING UNIT Battery Backup and Audible Alarm 8 - BLANK D - DIMMER CONTROLED DE - DEMOLITION DC - DRY COOLER EF - EXHAUST FAN ETR - EXISTING TO REMAIN F — FAN LTACONTROL GFI - GROUND FAULT INTERRUPT . . . .. ........ J - JUNCTION BOX CONTACTOR: NF - NON -FUSED 3 Pole, 240V, 30A with 120V coil in PNL- PANEL NEMA 1 enclosure. SO - SMOKE DETECTOR T - TIMER TIMERS TV - CABLE TELEVISION — -------- - ---- CONNECTION TIME CLOCK 240V, 40A, DPST UC - UNDER COUNTER Hardwired, Programmable, wl Battery UG - UNDER GROUND Backup and Rain Sensor Shutoff when VIF - VERIFY IN FIELD used for irrigation. WH - WATER HEATER WP - WEATHERPROOF SECURITY PANEL UNO UNLESS NOTED OTHERWISE VLOJ VERIFY LOCATION ON JOBSITE. REMOTE KEYPAD 120v, Hardwired, Programmabler W/ Battery Backup integrated VVith House LTG WALL SENSORS Security Alarm WALL MOUNTED "HUBBELL, LHUS 1W1 1E 1201277V OCCUPANCY SENSOR WTH T) Q C I ) �0 CD 00 0, a� I- Uj ol) z U ui LLJ U 0�� Lu LU U C) D_ CL __j 0 ILL I LU > H 0 LL F)2 C/) 1 0 0 LLJ 1-- 0 ry Z LLJ < IL 0 C) LU — Q:� z X < LU I In LU z X Lul 0 Florida-Caribbe,c Architectur 7 Erwood Place Boynton Beach, FL 33 (561) 308 6694 wwvv.FCArchitecture.( No. 75M 1. - - DPWN D. PETE jut,)CE, INC. �011% APVD D. PETE � M . e�m 5707 S. Dixie Hwy, #8 0 STATE OF 0%.IMPINEE) PROJ West Palm Beach, BY Florida 33405 ...... STLUCIE COILINTY, AL Phone: 561 436 9198 1/ v Fax: 561 4931560 Deveren Peterkh Cert, of Autl #8800 License #75256 CARIDDEAN AKCl­1ITffCTURE. 2015. XLL PIGI­1T5_ DWG E-1( TYPICAL SWITCH & RCPT MOUNTING NOT TO SCALE ELECTRICAL DESIGNATIONS 2 1/2- MIN. MIRROR. GFCI SWITCH ---- RECE A-15 1 5-15 MAX. 4' 0. * 3--a., GFCI 1EA4 r=54 RECEPTACLE­9� 3 IF COUNI is Fil I E 2 a 0 LESS THikN ;0' DEE�� 3 -6 FOR ACC S MA�.3- Fi� 31BLE� V I P 0 194 A-18 M A '51 E K -2 LAVATORY I 'EA -L-):3] A - T�l 2 A 13 +18 =1 2. B" ACCESSI E 77-71 ZF�l REG, LE KITCHEN BATHROOM EA-6 A-2 r= 7 14 ,D +56 _A 20 3Q+56 E5-ro E5-(O 15-18 E5-11 i C. A-18 A 4-18 1 1 5-15 A 5-15 2=0 5 1 1 3 3 J N F) R\y — 1-1611P URY 206 14-16 84" A EE A +84 A-18 rz -11 5-16 �iAL� -5,21 A- 4 6 (1/ LL _j NF EA20 3 3 N E14_1 (TO a�l 5-1 2 AHU-1 EA, -4 -4 0 EA_ E5_ 5-1 ___0V EA I ElvVi-H #2 t DAT�l 42 E EA-11 177 7 7) E5-11 A A A �z rz -11 E.5-11 3 5-1a 7 +18" +18" EA- i EA-5 I�L E5-8 40 +56- 2 JQ +56- �-20 EA-8 E -11 A-20 5-20 15- E5-8 A-20 3�� 5-20 B E D #3`1 A-20 3 QA-20 A 2=1 8 5-29 5-20(fl) 7 +56" EA-6 E� +56E�� :QEA-0 -20 5 -k=)r=A-a \�A-20 �,]:Q KEY NOTES: 3 A-20(p) 3 Q M-20 IN ATTIC. COORDINATE LUM4 MECHANICAL. 501b. RATED J-50X IN CEILING. DOWN TO LIGHT5 5r=L.OLU. SECOND FLOOR ELECTRICAL- PLAN 114" = 1 1-01' GFCI EPTACLE BASEMENT, LAUNDRY, UTILITY ROOM PLASMA TV LOCATIONS SYMBOL DESCRIPTION 12" SO. FLUORESCENT FIXTURE W1 ACRYLIC LENS (2-17W LAMPS). 1111.1_1.111111_;�� UN 0 1 X 4 FLUORESCENT FIXTURE W/LENSE (2-32W LAMPS) UNO S) 0 D .. ........... RECESSED CANLIGHT FIXTURE NTH INSULATED CASE HOUSING I.0 ­—­­­ — WALL MOUNTED LIGHT FIXTURE OVID RECESSED VAPORPROOF FIXTURE NTH INSULATED CASE HOUSING UNDERCABINET LIGHT WITH LENS. COMBO EXIT/EMERG. AND EXIT LIGHT FIXTURE W1 BATTERY BACK UP — — ----- - --------- - - -- EMERGENCY LIGHT FIXTURE W/ 13ATTERY BACK UP AIMABLE FLOOD LAMP W1 SECURITY AND DAYLIGHT SENSOR CONNECTED TO TIME CLOCK, TYP. CEILING FAN: 52' FOUR BLADE FAN W/ VARIABLE SPEED CONTROLS AND LIGHT MOUNT KIT OPTIONAL DUPLEX GFI RECEPTACLE AND LIGHT W/PULLCHAIN SWITCH IN ATTIC SWITCHES AND CONTROL DEVICES WITCHES AN! S_ SYMBOL S VM DECRIPTION BOL $ : SINGLE POLE SWITCH $3 [$FD 3 WAY SWITCH $4 f__$ 4 4 WAY SWITCH $D $ D ......... . ......... . . . . . . .............. DIMMER CONTROL SWITCH - DIMMER W/ MEMORY RECALL (DM) T FAN D' B SWITCH W1 FAN DELAY, ADJUSTABLE 5-60 MIN. S W! W DELA Y A A LE 5. -60 MIN $M 0 To R RA 1 E D D ISCON NE CT C H MOTOR RATED DISCONNECT SWITCH T M SU ST =CH( CON 0 L 0 ME TR PEAKER TE VOLUME CONTROL (SPEAKER SYSTEM) V LU ................................ .............. . DOOR BUZZER, PUSH BUTTON, 420 MOUNTING HEIGHT, U.N.O. . . . ............ TI El"GH U N 0. ;:;:p DOOR CHIME, 96- MOUNTING HEIGHT, U.N.O. qA.F.F., PUSH BUTTON ACTIVATOR, MOUNTING HEIGHT +48" U.N.O. Tl RECEPTACLES AND 016TLETS U SYMBOL DECRIPTION SIMPLEX RECEPTACLE 18" A.F.F., U.N.O. DUPLEX RECEPTACLE 18� A.F.F., U.N.O. wp DUPLEX RECEPTACLE WEATHERPROOF (WP) DUPLEX RECEPTACLE GROUND FAULT INTERRUPTER ... . . ...................... DUPLEX RECEPTACLE SWITCHED - LOWER OR BOTH SWITCHED ------ - ----------- ....... ... . ........ QUAD RECEPTACLE (TWO DUPLEXES) SPECIAL PURPOSE RECEPTACLE .3 WIRE W/GND VERIFY W/EQPT. WALL MOUNTED TELEPHONE/DATA OUTLET - la' A.F.F., U.N.O._ DUPLEX RECEPTACLE & TELEPHONE JACK IN FLOOR BOX, FLUSH MTD CABLE TELEVISION - 18" A.F.F., U.N.O. CIRCUITS ALL CIRUITS NEW, UNLESS NOTES 'ETR' HOMERUN - ONE ARROW PER CIRCUIT .............. . RACEWAY CONCEALED ABOVE CEILING OR IN WALL ELECTRICAL MECHANICAL EQUIPMENT E�m PANELBOARD (PNL) JUNCTION BOX - FAN (F), TIMER (T), BLANK (B) COMBINATION DISCONNECT / STARTER (OR CONTACTOR) 2 DISCONNECT SWITCH (SIZE NOTED; 2-NO. OF POLES, NF-NONFUSED, 60-FRAME SIZE) 00 0 FAN OR MOTOR - NUMERAL INDICATES HORSEPOWER MISCELLANEOUS DESIGNATIONS FIRE SMOKE SENSORS ABBREVIATIONS COMBINATION SMOKE ACT - ABOVE COUNTER TOP ALARM/CARBON MONOXIDE ZA ACU - AIR CONDENSING UNIT DETECTOR: AFF ABOVE FINISH FLOOR 120V, Hardwired, Single Station, w/ AHU AIR HANDLING UNIT Battery Backup and Audible Alarm. 8 - BLANK D - DIMMER CONTROLED DE - DEMOLITION DC - DRY COOLER EF - EXHAUST FAN ETR - EXISTING TO REMAIN F- FAN LTG CONTROL GFI - GROUND FAULT INTERRUPT . ...... . J - JUNCTION BOX F—CONTACTOR .. NIF - NON -FUSED 3 Pole, 240V, 30A with 120V coil in PNL- PANEL NEMA 1 enclosure. SC — SMOKE DETECTOR T - TIMER TIMERS TV - CABLE TELEVISION CONNECTION TIME CLOCK 240V, 40A, DPST: UC - UNDER COUNTER Hardwired, Programmable, wl Battery UG - UNDER GROUND Backup and Rain Sensor Shutoff when VIF - VERIFY IN FIELD used for irrigation, WH - WATER HEATER WP - WEATHERPROOF SECURITY PANEL UNO UNLESS NOTED OTHERWISE VLOJ VERIFY LOCATION ON JOBSITE. REMOTE KEYPAD: 120v, Hardwired, Programmable, w/ LTG WALL SENSORS Battery Backup integrated With House Security Alarm FIN] WALL MOUNTED "HUBBELL, LHUSS1W- SPEAKER SYSTEMS 120/277V OCCUPANCY SENSOR WITH MANUAL OVERRIDE SWITCH. I S P. Systems are MAXIMUM ::PAKER ",I a NOT S R bl�rI ttl%wner and ar TIME OUT TO BE 30 MINUTES IN Covered in the Project Scope AUTOMATIC MODE. FOR USE UP TO 400 S.F. MOUNTING HEIGHT +48" A F F /fit Pe kr N0.75256 IZT)C-E, INC. 5707 S. Dixie Hwy #8 IrrATE OF West Palm Beach, Florida 33405 Phone: 561 436 9198 Fax: 561 493 1560 Deveren Pet kin Cert. of Auth.: #8800 License #75 6 tn 7 Erwood PI Boynton Beach, (561) 3086 www.FCArchitec AA2600215 D5GN C D KW N C APV1) PPIOJ JULY BYDWG E F�LENAM[f;