HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017
FLORIDA ENERGY EFFICI � N
Florida Department of Business ap4q.
0
FOR BUILDING CONSTRUCT,
:gelation - Residential Performance Method\
Project Name: Unit B West Facing
Street: 257-259 Dixieland Drive
State, Zip: Ft. Pierce , FL, 34982
Owner: Oleander Properties Dixieland LLC
•Design Location: FL, Fort Pierce
Builder Name: Southern City DevelopmeL
Permit Office: St. Lucie County Bldg DiviACity,
Permit Number:1808-0219 OV 2 6 2018
Jurisdiction: Planning/Dev. Servic
County: St.Lucie (Florida Climate @if3 Ppwrltyf MPMI4,1fi
1. New construction or existing New (From Plans)
9. Wall Types (1433.8 sqft.)
Insulation Area
2. Single family or multiple family Mulflfamily
a. Concrete Block - Int Insul, Exterior
R=4.1 1333.80 ftz
b. Frame - Steel, Adjacent
R=13.0 100.00 ftz
3. Number of units, if multiple family 1
c. N/A
R= ftz
4. Number of Bedrooms 3
d. N/A
R= ftz
10. Ceiling Types (949.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 949.00 ftz
6. Conditioned floor area above grade (ftz) 1566
b. N/A
R= ftz
c. N/A
R= ftz
Conditioned floor area below grade (ftz) 0
11. Ducts
R ftz
7. Windows(230.0 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Second Floor 6 , 85
a. U-Factor: Sgl, U=1.10 160.00 ftz
SHGC: SHGC=0.39
b. U-Factor: Sgl, U=1.01 40.00 ftz
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.48
a. Central Unit
35.0 SEER:16.50
c. U-Factor: Sgl, U=1.10 30.00 ftz
SHGC: SHGC=0.39
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ftz
a. Electric Strip Heat
19.7 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 2.406 ft.
Area Weighted Average SHGC: 0.406
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (617.0 sqft.) I sulation Area
EF: 3.691
a. Slab -On -Grade Edge Insulation R=0.0 617.00 ftz
b. Conservation features
b. N/A R= ftz
None
c. N/A �= ftz
15. Credits
Pstat
Glass/Floor Area: 0.147 Total Proposed Modified Loads: 50.56
PASS
1 111 / /// Total Baseline
Loads: 54.91
I,tiereby certify that the pla3ls( ¢'§pt fif rts'CA e¢.by
in theFlorida
Review of the plans and
specifications covered by this
D�T� S7.4
tfiis,calculafon-are corJ;rplNl j e witgj;
Code. _ o. 69753
calculation indicates compliance
_ =
with the Florida Energy Code.
r. x. •
;%;., . ,, �
PREPARED BY:
Before construction is completed
DATE:
this building will be inspected for
0
ST o
R `
r' Ides ed'`� a?npliance
I hereby certify that this buirgy
compliance with Section 553.908
Florida Statutes.
*.
C
with the Florida EneONAL ����
OD We .
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the.air handler end_ I-osure qualifies "as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.25 ACH50 (R402.4.1.2).
11/20/2018 8:08 AM EnorgyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4
;:n.'Qnn'RAN;_7n17
i
IKIPI IT CI IMMARY
C.I4FC.KI IST RFP()RT
I PROJECT
Title:
Unit B West Facing
Bedrooms: 3
Address Type: Street Address
Building Type:
User
Conditioned Area: 1566
Lot #
Owner Name:
Oleander Properties Dixieland
Total Stories: 2
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Southern City Development
Rotate Angle: 0
Street: 257-259 Dixieland Drive
Permit Office:
St. Lucie County Bldg Division
Cross Ventilation:
County: St. Lucie
Jurisdiction:
Planning/Dev. Servic
Whole House Fan:
City, State, Zip: Ft. Pierce ,
Family Type:
Multi -family
FL, 34982
New/Existing:
New (From Plans)
Comment:
I
CLIMATE
V
Design Temp
Int Design Temp Heating Design Daily Temp
Design Location TMY Site
I
97.5 % 2.5 %
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_B ACH_MUNI 39 90
70
75 299 62 Low
I
BLOCKS
Number
Name Ara
Volume
1
Blockl 1P66
13762
SPACES
Number
Name Ara
Volume Kitchen Occupants
Bedrooms Infil ID Finished Cooled Heated
1
First Floor 61
6170 Yes 0
0
1 Yes Yes Yes
2
Second Floor 9 9
7592 No 3
3
1 Yes Yes Yes
I
FLOORS
#
Floor Type Space
Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio First Floor 132 ft 0
617 ft2
---_ 0 0 1
I
ROOF
Roof Gable Roof
Rad
Solar SA Emitt Emitt Deck Pitch
V #
Type Materials
Area Area Color
Barr
Absor. Tested Tested Insul. (deg)
1
Hip Com j osition shingles
1000 ft2 0 ft2 Light
N
0.75 No 0.9 No 0 18.4
I
ATTIC
V
I
#
Type Ventilation Vent Ratio (1 in)
Area
FIBS IRCC
1
Full attic Vented 300 949 ft2
N N
1
CEILING
#
Ceiling Type
Space R-Value Ins Type
Area Framing Frac Truss Type
1
Under Attic (VenteId) Second Floor 30 Blown
949 ft2 0.11 Wood
11/20/2018 8:08 AM
Ene gyGauge® USA 6.0.02
(Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FnR1VI'R405-2017 INPl1T SU MARY CHECKLIST REPORT
WALLS
Adjacent Cavity Width Height
Sheathing Framing Solar
Below
Space
_ 1 S
Exterior Concrete Block - Int InsrI I First Floor 4.1 28 4 10
0
283.3 ftz
0 0.2
0
_ 2 W
Exterior Concrete Block - Int InZ First Floor 4.1 13 7 10
0
135.8 ftz
0 0.2
0
3 E
Exterior Concrete Block - Int InIl First Floor 4.1 24 0 10
0
240.0 ftz
0 0.2
0
_
4 S
Exterior Concrete Block - Int InstSecond Floor 4.1 35 8 8
0
285.3 ftz
0 0.2
0
_
5 E
Exterior Concrete Block - Int I siSecond Floor 4.1 24 4 8
0
194.7 ft2
0 0.2
0
6 W
Exterior Concrete Block - Int I s6Second Floor 4.1 24 4 8
0
194.7 ftz
0 0.2
0
7 W
Garage Frame - Steel First Floor 13 10 0 10
0
100.0 ftz
0.1 0.2
0
DOORS
#
Ornt Door Type I Space Storms
U-Value
Width Height
Area
Ft
In Ft In
1
W Insulated I First Floor None
.46
3
6 8
20 ftz
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V #
Ornt ID Frame Panes NFRC U-Factor SHGC Imp
Area
Depth
Separation Int Shade
Screening
1
S 1 Metal Single (Clea) Yes 1.01 0.48 Y
40.0 ftz
1 ft 8 in
2 ft 0 in Drapes/blinds
None
2
W 2 Metal Single (Cle r) Yes 1.1 0.39 Y
30.0 ftz
7 ft 4 in
2 ft 0 in Drapes/blinds
None
3
E 3 Metal Single (Clesr) Yes 1.1 0.39 Y
60.0 ftz
1 ft 8 in
2 ft 0 in Drapes/blinds
None
4
S 4 Metal Single (Clef r) Yes 1.1 0.39 Y
16.7 ftz
1 ft 8 in
2 ft 0 in Drapes/blinds
None
5
E 5 Metal Single (CIar) Yes 1.1 0.39 Y
30.0 ftz
1 ft 8 in
2 ft 0 in Drapes/blinds
None
6
W 6 Metal Single (Cl ar) Yes 1.1 0.39 Y
23.3 ftz
1 ft 8 in
2 ft 0 in Drapes/blinds
None
7
W 6 Metal Single (Tited) Yes 1.1 0.39 Y
30.0 ftz
1 ft 8 in
2 ft 0 in Drapes/blinds
None
I GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
200 ftz 200 ftz 64 ft
8 ft
1
INFILTRATION
# Scope
Method SLA CFM 50 ELA EgLA
ACH
ACH 50
4 Wholehouse Proposed ACH(50) 000293 1203.3 66.06 124.23
.1391
5.246
I HEATING SYSTEM
#
System Type Subtype Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat I None COP:1
19.7 kBtu/hr
1
sys#1
11/20/2018 8:08 AM Energ'yGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FntQnn IQAnr,_7ni7 IKIPI IT CI IMMARV r:HFC.KI_IRT RFPORT
- - -
-- -- -
- - - --
I
COOLING SYSTEM
# System Type
SuWpe
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
SEER: 16.5 35 kBtu/hr
1200 cfm
0.75
1
sys#1
I
HOT WATER SYSTEM
-
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
Heat Pump
arage
3.690654 50 gal
50 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model # Area
Volume
FEF
None None
ft2
DUCTS
---- Supply ----
---- Return ----
Air
CFM 25
CFM25
HVAC #
V/ # Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT QN
RLF
Heat Cool
1 Attic
6 85 ft2
Attic
25 ft2 Default Leakage
Second Flo
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Coolie [[ ]] Jan [[ ]] Feb
Heating [X] Jan [X] Feb
Mar
Mar
A r
APr [
[ j May [X] Jun X Jul
]May ] Jun Jul
Au
4 Aug
Sep
rl Se
[ ]Oct
[ ] Oct
Nov
Nov
Dec
Dec
Ventin [[ ]] Jan [[ ]] Feb
X
X Mar
[X) A r [
] Ma ] Jun Jul
E
[ Au
Se
[X] Oct
X Nov
Dec
Thermostat Schedule: HERS 2006 Referenda
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD) AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 78
78 78 78
78
78
78
78
78
78
Cooling (WEH) AM
78
78 78
78 78 78
78
78
78
78
78
78
PM
78
78 78
78 78 78
78
78
78
78
78
78
Heating (WD) AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
Heating (WEH) AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
I
0 ft2
0 ft
0.3
First Floor
Default 8 Ibs/s .ft.
0 ft2
0 ft
0.3
Second Floor
11/20/2018 8:08 AM EhergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
Buildir�I Input Summary Report
I
PROJECT
Title:
Unit B West Facing I
Address type:
S
Building Type:
User
Bedrooms: 3
Lot #:
Owner:
Oleander Properties Dixieland LL P
Conditioned Area: 1566
Block/SubDivision:
Total Stories: 2
PlatBook:
Builder Name:
Southern City Development
Worst Case: No
Street:
257-259 Dixieland
Drive
Permit Office:
St. Lucie County Bldg Division
Rotate Angle: 0
County:
St. Lucie
Jurisdiction:
Planning/Dev. Servic
Cross Ventilation:
City, State, Zip:
Ft. Pierce,
Family Type:
Multi -family
Whole House Fan:
FL, 34982
New/Existing:
New (From Plans)
Terrain: Urban
Year Construct:
2018
Shielding: Urban
Comment:
CLIMATE
Design
Design Temp
Int Design Temp Heating
Design
Daily temp
V Location
TmI Site
97.5% 2.5%
Winter Summer Degree Days
Moisture
Range
FL, Fort Pierce FL_VERC>_BEACH_MUNICIPA 39 90
I
70 75 299
62
Low
I
UTILITY
Fuel
Unit Utility Name
Monthly Fixed Cost
$/Unit
Electricity
kWh Florida Av�rage
0.00
0.12
_ Natural Gas
Therm Florida A4rage
0.00
1.72
Fuel Oil
Gallon Florida Default
0.00
1.10
_
Propane
Gallon Florida Default
0.00
3.13
I
SURROUNDINGS
------------Shade Trees --------------
----------Adjacent Buildings----------
Ornt Type
Height Width Distance
Exist Height
Width
Distance
N None
Oft Oft Oft
Oft
Oft
Oft
NE None
Oft Oft Oft
Oft
Oft
Oft
E None
Oft Oft Oft
Oft
Oft
Oft
SE None
Oft Oft Oft
Oft
Oft
Oft
S None
Oft Oft Oft
Oft
Oft
Oft
.SW None
Oft Oft Oft
Oft
Oft
Oft
W None
Oft Oft Oft
Oft
Oft
Oft
NW None
Oft Oft Oft
Oft
Oft
Oft
BLOCKS
Number
Name Area
Volume
_ 1
Blockl I 1566
13762
I
SPACES
Number
Name I Area
Volume Kitchen Occupants
Bedrooms Finished
Cooled Heated
—1
First Floor 617
6170 Yes 0
0 Yes
Yes
Yes
2 Second Floor 949
7592 No 3
3 Yes
Yes
Yes
11/20/2018 8:09:36 AM I EnergyGauge®/ USRCSB v6.1 Page 1
Building Input Summary Report
I
FLOORS
(Total Exposed Area = 617 sq.ft.)
# Floor Type
Space
I Exposed Perim Perimeter R-Value
Area U-Factor Joist R-Value Tile Wood Carpet
_ 1 Slab -On -Grade Edge Ins First Floo�
132 0
617 it 0.304 --- 0 0 1
ROOF
Roof Gable Roof
Rad Solar SA Emitt Emitt Deck Pitch
V# Type
Mated s
Area Area Color
Barr Absor. Tested Tested Insul. (deg)
1 Hip
Composition shingles 1000 ft2 0 ft2 Light
N 0.75 No 0.9 No 0 18.4
I
ATTIC
# Type
Jentilatlon Vent Ratio (1 in) Area RBS IRCC
1 Full attic
Vented 300 949 ft2 N N
CEILING
(Total Exposed Area = 949 sq.ft.)
# Ceiling Type
Space R-Value Ins. Type
Area U-Factor Framing Frac. Truss Type
-1 Under Attic(Vented)
Second Floor 30.0 Blown
949.0ft2 0.055 0.11 Wood
WALLS
(Total Exposed Area = 1434 sq.ft.)
Adjacent
Cavity Width
Height Area U- Sheath Frm. Solar Below
✓# Omt To
Wall Type
Space R-Value Ft In
Ft In sq.ft. Factor R-Value Frac. Absor. Grade
_ 1 S Exterior
Conc. Blk - ant Ins
First Floor 4.1 28.0 4
10.0 0 283.3 0.149 0 0.2 0 %
_ 2 W Exterior
Conc. Blk - Int Ins
First Floor 4.1 13.0 7
10.0 0 135.8 0.149 0 0.2 0 %
_ 3 E Exterior
Conc. Blk Int Ins
First Floor 4.1 24.0 0
10.0 0 240.0 0.149 0 0.2 0 %
_ 4 S Exterior
Conc. Blk - Int Ins
Second Floor 4.1 35.0 8
8.0 0 285.3 0.149 0 0.2 0 %
5 E Exterior
Conc. BlkInt Ins
Second Floor 4.1 24.0 4
8.0 0 194.7 0.149 0 0.2 0'/0
_ 6 W Exterior
Conc. Blk - Int Ins
Second Floor 4.1 24.0 4
8.0 0 194.7 0.149 0 0.2 0 %
7 W Garage
Frame - Steel
First Floor 13.0 10.0 0
10.0 0 100.0 0.162 0.1 0.2 0 %
DOORS
(Total Exposed Area = 20 sq.ft.)
Width Height
V. # Ornt Adjacent To Doo Type
Space Storms
U-Value Ft In Ft In Area
1 W Exterior
In ulated
First Floor None
0.46 3.00 0 6.00 8 20.0ftz
WINDOWS
(Total Exposed Area = 230 sq.ft.)
Wall
✓# Ornt ID Frame
I
Panes NFRC
U-Factor SHGC Imp Storm, Area
----- Overhang -----
Depth Separation Interior Shade Screening
1 S 1 Metal
Single (Clear) Yes
1.01 0.48 Y N 40.0ft2
1.0 it 8 in 2.0 it 0 in Drapes/blinds None
2 W 2 Metal
Singe (Clear) Yes
1.10 0.39 Y N 30.0ft2
7.0 it in 2.0 it in Drapes/blinds None
3 E 3 Metal
Single (Clear) Yes
1.10 0.39 Y N 60.0ft2
1.0 it 8 in 2.0 it 0 in Drapes/blinds None
-4 S 4 Metal
Single (Clear) Yes
1.10 0.39 Y N 16.7ft2
1.0 it 8 in 2.0 it 0 in Drapes/blinds None
-5 E 5 Metal
Single (Clear) Yes
1.10 0.39 Y N 30.Oft2
1.0 it 8 in 2.0 it 0 in Drapes/blinds None
-6 W 6 Metal
Sin' le (Clear) Yes
1.10 0.39 Y N 23.3ft2
1.0 it 8 in 2.0 it 0 in Drapes/blinds None
7 W 6 Metal Sin le (Tinted) Yes
1.10 0.39 Y N 30.0ft2
1.0 it 8 in 2.0 it 0 in Drapes/blinds None
11/20/2018 8:09:36 AM I EnergyGauge® / USRCSB v6.1 Page 2
Buildi 7g Input Summary Report
INFILTRATION
# Scope Method
S'L/A
CFM50 ELA EgLA ACH ACH50 Space(s)
1 Wholehouse Proposed ACH(50) 0.00029
1203 66.06 124.23 0.1391 5.2 All
GARAGE
# Floor Area
''
Roof AI ea
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 200 ft2
200Ift2
64 ft 8 ft 1
MASS
# Mass Type
I Area
Thickness Furniture Fraction Space
_ 1 Default(8 Ibs/sq.ft.)
2 Default(8 Ibs/sq.ft.)
0 ft2
0 ft2
0 ft 0.30 First Floor
0 ft 0.30 Second Floor
HEATING SYSTEM
# System Type
S/1btype
AHRI # Efficiency Capacity ----Geothermal HeatPump---- Ducts Block
kBtu/hr Entry Power Volt Current
1 Electric Strip Heat
None
COP: 1.00 19.7 0.00 0.00 0.00 sys#1 1
f
COOLING SYSTEM
# System Type
Subtype
AHRI # Efficiency Capacity Air Flow SHR Duct Block
kBtu/hr cfm
1 Central Unit
Split
SEER:16.5 35.0 1200 0.75 sys#1 1
HOT WATER SYSTEM
# System Type Subtype
I Location
EF(UEF) Cap Use 'SetPnt Fixture Flow Pipe Ins. Pipe length
1 Electric Heat Pump
Garage
3.69 (3.55) 50.00 gal 50 gal 120 deg Standard None 74
Recirculation Recirc1,Control
System T pe
i
Loop Branch Pump DWHR Facilities Equal DWHR Other Credits
length length power Connected Flow Eff
1 No I
NA NA NA No NA NA NA None
DUCTS
Duct---------Supply------------------Return--------- Air CFM 25 CFM 25 HVAC #
# Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT QN RLF Heat Cool
_ 1 Attic 6.0 15 ft2
Attic
6.0 25 ft2 Default Leakage Second Flo (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat: YI
Cooling [ ] Jan [ ] Feb
Heating [X] Jan [X] F4eb
Venting [ ] Jan [ ] iWleb
(] Mar [ ] Apr
[Xj Mar [ ] Apr
[X] Mar [X] Apr
Ceiling Fans: N
[ ] May [X] Jun, [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] May [ ] Jun []Jul [ ] Aug [ ] Sep [ ] Oct [X] Nov [X] Dec
[ ] May [ ] Jun []Jul [ ] Aug [ ] Sep [X] Oct [X] Nov [] Dec
11/20/2018 8:09:36 A
EnergyGauge® / USRCSB v6.1
Page 3
Buildi 7 g Input Summary Report
TEMPERATURES(Continued)
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
781
78
78
78
78
78
78
80
80
80
80
_
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
76
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
6B
8
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MISC ELECTRICAL LOADS
ID Type
Screen
I Location
Item
Quantity
Catagory
Operating Schedule
Off Standby
_ 1 Misc Elec Load Simple Default I
Main
1
1
HERS2011
1
APPLIANCES & LIGHTING SCHEDULES
Appliance Schedule:
HERS2014
Hours
Schedule Type
1 I
2
3
4
5
6
7
8
9
10
11
12
Occupancypeak:
400 Btu
AM
I
0.930
0.930
0.930
0.930
0.930
0.930
0.930
0.980
0.460
0.270
0.270
0.270
% Released:
100 %
PM
0.270
0.270
0.270
0.270
0.330
0.610
1.000
1.000
0.930
0.930
0.930
0.930
refrig peak:
0 W
AM
0.824
0.804
0.784
0.764
0.744
0.734
0.744
0.754
0.764
0.794
0.814
0.854
% Released:
100 %
PM
0.$54
0.864
0.884
0.904
0.925
0.945
0.925
0.915
0.904
0.894
0.874
0.854
calash peak:
0 W
AM0_rr(I200
0.100
0.050
0.050
0.050
0.075
0.200
0.375
0.500
0.800
0.950
1.000
% Released:
30 %
PM
0.875
0.850
0.800
0.625
0.625
0.600
0.575
0.550
0.625
0.700
0.650
0.375
E-cDry peak:
0 W
AM
.200
0.100
0.050
0.050
0.050
0.075
0.200
0.375
0.500
0.800
0.950
1.000
% Released:
15 %
PM
0.875
0.850
0.800
0.625
0.625
0.600
0.575
0.550
0.625
0.700
0.650
0.375
dWash peak:
0 W
AM
0.139
0.050
0.028
0.024
0.029
0.090
0.169
0.303
0.541
0.594
0.502
0.443
"% Released:
60 %
PM
0.376
0.396
0.334
0.323
0.344
0.448
0.791
1.000
0.800
0.597
0.383
0.281
E-rOven peak:
0 W
AM
0.057
0.057
0.057
0.057
0.057
0.114
0.171
0.286
0.343
0.343
0.343
0.400
% Released:
80 %
PM
0.457
0.343
0.286
0.400
0.571
1.000
0.857
0.429
0.286
0.229
0.171
0.114
TVs peak:
226 W
AM
0.100
0.050
0.050
0.050
0.100
0.200
0.400
0.450
0.400
0.200
0.100
0.100
Released:
100 %
Pry
0.050
0.050
0.150
0.450
0.850
1.000
0.950
0.800
0.500
0.250
0.150
0.100
cFan peak:
0 W
AM
0.600
0.600
0.600
0.600
0.600
0.600
0.600
0.250
0.250
0.250
0.250
0.250
% Released:
100 %
PM
0.250
0.250
0.250
0.250
0.250
0.250
0.550
0.600
0.600
0.600
0.600
0.600
Igts-in peak:
0 W
L
0.160
0.150
0.160
0.180
0.230
0.450
0.420
0.260
0.190
0.160
0.120
0.110
% Released:
100 %
bM
0.160
0.170
0.250
0.270
0.340
0.550
0.600
0.880
1.000
0.880
0.510
0.280
Igts-out peak:
0 W
AM
1.000
1.000
1.000
1.000
1.000
0.750
0.750
0.000
0.000
0.000
0.000
0.000
% Released:
0 %
PM
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.500
0.750
0.750
0.750
1.000
Igts-gar peak:
0 W
AM
0.000
0.000
0.000
0.000
0.000
0.500
0.750
1.000
0.750
0.500
0.000
0.000
% Released:
0 %
PM
0.000
0.000
0.500
0.500
0.750
1.000
0.750
0.500
0.000
0.000
0.000
0.000
MEL peak:
0 W
AM
0.500
0.500
0.500
0.750
0.750
0.850
1.000
1.000
1.000
1.000
0.900
0.900
% Released:
90 %
PM
0.900
0.900
1.000
1.000
1.000
1.000
1.000
1.000
1.000
0.850
0.750
0.750
11/20/2018 8:09:36 AM
EnergyGauge® / USRCSB v6.1
Page 4
v
2617 EPL DISPLAY CARD
ENERGY PER
ESTIM
The lower the
1. New home or, addition
r 2. Single-family or multiple -family
3. No. of units (if multiple -family)
4. Number of bedrooms
5. Is this a worst case? (yes/no)
6. Conditioned floor area (sq. ft.)
7. Windows, type and area
a) U-factor:(weighted a
b) Solar Heat Gain Coe
c) Area
8. Skylights
a) U-factor:(weighted
b) Solar Heat Gain C
9. Floor type, insulation level:
a) Slab -on -grade (R-value
b) Wood, raised (R-valuejj
c) Concrete, raised (R-val
10. Wall type and insulatic
A. Exterior:
1. Wood frame (Insula
2. Masonry (Insulation
B. Adjacent:
1. Wood frame (Insula
2. Masonry (Insulation
RMANCE LEVEL (EPL) DISPLAY CARD
;D ENERGY PERFORMANCE INDEX* = 92
Performance Index, the more efficient the home.
1. New (From Plans) 12. Ducts, location & insulation level
a) Supply ducts
R
6.0
2. Multi -family
b) Return ducts
R
6.0
c) AHU location
Second Floor
3.
1
4.
3
13. Cooling system:
Capacity
35.0
a) Split system
SEER
16.5
5.
No
b) Single package
SEER
c) Ground/water source SEER/COP
6.
1566
d) Room unit/PTAC
EER
e) Other
7a.
1.084
(SHGC) 7b.
0.406
14. Heating system:
Capacity
19.7
7c.
230.0
a) Split system heat pump
HSPF
b) Single package heat pump HSPF
c) Electric resistance
COP
1.0
8a.
NA
d) Gas furnace, natural gas
AFUE
(SHGC) 8b.
NA
e) Gas furnace, LPG
AFUE
f) Other
i 9a. 0.0
9b.
15. Water heating system
ie) 9c.
a) Electric resistance EF 3.69
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
R-value) 10A1.
e) Dedicated heat pump with tank EF
alue) 10A2. 4.1
f) Heat recovery unit HeatRec%
g) Other
ion R-value)
R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
10131. 13.0
1062.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11 a. 30.0
b) Cross ventilation No
11 b.
c) Whole house fan No
11c.
d) Multizone cooling credit
11 d. No
e) Multizone heating credit
f) Programmable thermostat Yes
*Label required by Sdetion R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, anew EPL
display card will be completed based on installed code compliant features.
Builder
Date:
Address of New Home: 257-259 Dixieland Drive City/FL Zip: Ft. Pierce, FL 34982
11/20/2018 8:09:05 AM/ EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Air System Sizing Summary for Unit A ,B1
Project Name: Dixieland Townhomes
06/01/201
10:53AI
Air System Information
Air System Name ......................................................... Unit ,B1 Number of zones.----------.....------•-•-----..............................-----............----1
Equipment Class.........................................................
--------•---------------•- .....................---- SPLTJAHU Floor Area ........................ ............................................................. 1654.0 ft2
Air System Type..............................-------........................... SZCAV Location............................................................. Fort Pierce, Florida
Sizing Calculation Information
Zone and Space Sizing Method:
Zone CFM.................................. Sum of space airflo rates Calculation Months.......................................................... Jan to Dec
Space CFM ............................. Individual peak space loads Sizing Data ................................................................ Calculated
Central Cooling Coil Sizing Data
Total coil load---...-------------------••----...............-------...................2.9 Tons Load occurs at--------------------................•----............................ Jun 1600
Total coil load ...................................... ---......------......---.I-----.....35.3 MBH OADB/WB._.....-•--•---------------------------.....----....................90.5176.9 OF
Sensible coil load ......................................................... 1....-------30.8 MBH Entering DB / WB............................................................. 73.0 / 59.2 OF
Coil CFM at Jun 1600 .................................. - -1200 CFM Leaving DB / WB----........................-----•-........................49.2 / 48.0 OF
Maxblock CFM....---••-...................................... - - - ..........1200 CFM Coil ADP.-------------------------------.............---------......----------............. 46.6 OF
Sum of peak zone CFM--•--------------------..............................1200 CFM Bypass Factor ............................................................................... 0.100
Sensible heat ratio--- ........................... ...................... ............. 0.873 Resulting RH-------------------..................--------------------------.................44 %
ft2rron.....................-------..............----------------------....................562.2 Design supply temp ...................................................................... 47.5 OF
BTU/(hr-ft-)................•--------------------------•-............................. 21.3 Zone T-stat Check------------------------...........------............-----......... 0 of 1 OK
Water flow @ 10.0 OF rise ..................................................... NIA Max zone temperature deviation ................................................. 0.0 OF
Central Heating Coil Sizing Data
Maxcoil load ............................................... ......... ...................... 14.3 MBH Load occurs at ..................... .................................................... Des Htg
CoilCFM at Des Htg......--....................................................1200 CFM BTU/(hr-ft2).-----•------------------...-------...------...........-•.----.......................8.7
Max coil CFM......................... '........................... I ...................... 1200 CFM Ent. DB / Lvg DB............................................................... 69.7 / 80.8 OF
Water flow @ 20.0 OF drop .---------- .............................-----.. NIA
Supply Fan Sizing Data
Actual max CFM ................................................ ...........................1200 CFM Fan motor BHP -------------- --------------------------------......--------............. 0.17 BHP
Standard CFM............ .................................. ............................ 1198 CFM Fan motor kW...........----------------.....----..........................---............ 0.13 kW
Actualmax CFM/ft2-------------------•--........................................... 0.73 CFM/ftZ Fan static..... ----------------------------------........----.....................-.......... 0.50 in wg
Outdoor Ventilation Air Data
Design airflow CFM..................................----............................... 0 CFM CFM/person-----------------------........................................-..................0.00 CFM/person
CFM/n2....................................................... ..................................0.00 CFM/ft2
=ECEED
\\\��,, i l l ►, �,,��� r �
71
o��; N. I •fie
Hourly Analysis Prograrp v.4.2
Page 1 of 1
[Project Name: Dbdeland Townhomes Air
Sizing Summary for Unit B2
06/01/201
10:59AI
Air System Information
Air System Name ............................................... ................ U it B2
Number of zones.....................-•-•--........---------------------.........-•--------.....1
Equipment Class .--------------------- ................................ SPLTIAHU
Floor Area .....................................................................................
1654.0
ft'
Air System Type---.........................•............•.................. SZCAV
Location .............................................................
Fort Pierce, Florida
Sizing Calculation, Information
Zone and Space Sizing Method:
Zone CFM.................................. Sum of space airflo rates
Calculation Months .............................. _.......................... Jan to Dec
Space CFM ............................. Individual peak spac loads
Sizing Data .........................................................................
Calculated
Central Cooling Coil Sizing Data
Total coil load .................................................. ...... 2.5
Tons
Load occurs at.......-------...............................--......--------........Jul
1700
Total coil load.......................................................................... 29.6
MBH
OA DB / WB.....................---------------------..............................90.5
/ 76.6
°F
Sensible coil load ................................................................ ......25.6
MBH
Entering DB / WB....................... -............
........................ 73.0159.4
OF
Coil CFM at Jul 1700----------------•-•.................---......-..........1000
CFM
Leaving DB / WB...............................................................
49.3 / 48.0
OF
Maxblock CFM--...........:.....•-•-••---.-_.-------------......................1000
CFM
Coil ADP------------------------.......--.•.-•-----•--------------------------.................
46.6
OF
Sum of peak zone CFM.................................................. ...... 1000
CFM
Bypass Factor ...............................................................................
0.100
Sensible heat ratio ................................................... ......... ..... 0.865
Resulting RH----...---------------------_.............-------•----------.....................44
%
ft'/Ton........................_............................................--................. 669.5
Design supply temp ......................................................................
47.7
OF
BTU/(hr-ft')..------••-------•-------------................................................17.9
Zone T-stat Check ......................................................................
0 of 1
OK
Water flow @ 10.0 OF rise ..................................................... WA
Max zone temperature deviation
................................................. 0.0
OF
Central Heating Coil Sizing Data
"
Maxcoil load................•-•-•-----------------.......................... ---.......10.2
MBH
Load occurs at .........................................................................
Des Htg
Coil CFM at Des Htg............................................................. 1000
CFM
BTU/(hr-ft').......................................................................................... 6.2
Max coil CFM---•---..........................•-•----•----.............................1000
CFM
Ent. DB / Lvg DB...............................................................
69.9 / 79.3
OF
Water flow @ 20.0 OF drop ............ . .................................... NIA
Supply Fan Sizing Data
Actual max CFM .......................................................... ............1000
CFM
Fan motor BHP ...............................................................................
0.15
BHP
StandardCFM....................................................-............-------- 999
CFM
Fan motor kW-------•--------------•-----------................................................
0.11
kW
Actual max CFM/ft'................................................... .............. 0.60
CFM/ft'
Fan static ........................................................................................... 0.50
in wg
Outdoor Ventilation Air Data
Design airflow CFM---....................................•----......................... 0
CFM
CFM/person............................................---...............•----..................0.00
CFM/person
CFM/ft'...................................--------.....------------...........................0.00
CFM/ft'
\\\\��l►IIIII
q l
AF
oR/D
Hourly Analysis Program v.4.2 I Page 1 of 1