Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICI � N Florida Department of Business ap4q. 0 FOR BUILDING CONSTRUCT, :gelation - Residential Performance Method\ Project Name: Unit B West Facing Street: 257-259 Dixieland Drive State, Zip: Ft. Pierce , FL, 34982 Owner: Oleander Properties Dixieland LLC •Design Location: FL, Fort Pierce Builder Name: Southern City DevelopmeL Permit Office: St. Lucie County Bldg DiviACity, Permit Number:1808-0219 OV 2 6 2018 Jurisdiction: Planning/Dev. Servic County: St.Lucie (Florida Climate @if3 Ppwrltyf MPMI4,1fi 1. New construction or existing New (From Plans) 9. Wall Types (1433.8 sqft.) Insulation Area 2. Single family or multiple family Mulflfamily a. Concrete Block - Int Insul, Exterior R=4.1 1333.80 ftz b. Frame - Steel, Adjacent R=13.0 100.00 ftz 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 3 d. N/A R= ftz 10. Ceiling Types (949.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 949.00 ftz 6. Conditioned floor area above grade (ftz) 1566 b. N/A R= ftz c. N/A R= ftz Conditioned floor area below grade (ftz) 0 11. Ducts R ftz 7. Windows(230.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Second Floor 6 , 85 a. U-Factor: Sgl, U=1.10 160.00 ftz SHGC: SHGC=0.39 b. U-Factor: Sgl, U=1.01 40.00 ftz 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.48 a. Central Unit 35.0 SEER:16.50 c. U-Factor: Sgl, U=1.10 30.00 ftz SHGC: SHGC=0.39 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a. Electric Strip Heat 19.7 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.406 ft. Area Weighted Average SHGC: 0.406 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (617.0 sqft.) I sulation Area EF: 3.691 a. Slab -On -Grade Edge Insulation R=0.0 617.00 ftz b. Conservation features b. N/A R= ftz None c. N/A �= ftz 15. Credits Pstat Glass/Floor Area: 0.147 Total Proposed Modified Loads: 50.56 PASS 1 111 / /// Total Baseline Loads: 54.91 I,tiereby certify that the pla3ls( ¢'§pt fif rts'CA e¢.by in theFlorida Review of the plans and specifications covered by this D�T� S7.4 tfiis,calculafon-are corJ;rplNl j e witgj; Code. _ o. 69753 calculation indicates compliance _ = with the Florida Energy Code. r. x. • ;%;., . ,, � PREPARED BY: Before construction is completed DATE: this building will be inspected for 0 ST o R ` r' Ides ed'`� a?npliance I hereby certify that this buirgy compliance with Section 553.908 Florida Statutes. *. C with the Florida EneONAL ���� OD We . OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the.air handler end_ I-osure qualifies "as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.25 ACH50 (R402.4.1.2). 11/20/2018 8:08 AM EnorgyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 ;:n.'Qnn'RAN;_7n17 i IKIPI IT CI IMMARY C.I4FC.KI IST RFP()RT I PROJECT Title: Unit B West Facing Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1566 Lot # Owner Name: Oleander Properties Dixieland Total Stories: 2 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Southern City Development Rotate Angle: 0 Street: 257-259 Dixieland Drive Permit Office: St. Lucie County Bldg Division Cross Ventilation: County: St. Lucie Jurisdiction: Planning/Dev. Servic Whole House Fan: City, State, Zip: Ft. Pierce , Family Type: Multi -family FL, 34982 New/Existing: New (From Plans) Comment: I CLIMATE V Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site I 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_B ACH_MUNI 39 90 70 75 299 62 Low I BLOCKS Number Name Ara Volume 1 Blockl 1P66 13762 SPACES Number Name Ara Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 First Floor 61 6170 Yes 0 0 1 Yes Yes Yes 2 Second Floor 9 9 7592 No 3 3 1 Yes Yes Yes I FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio First Floor 132 ft 0 617 ft2 ---_ 0 0 1 I ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Com j osition shingles 1000 ft2 0 ft2 Light N 0.75 No 0.9 No 0 18.4 I ATTIC V I # Type Ventilation Vent Ratio (1 in) Area FIBS IRCC 1 Full attic Vented 300 949 ft2 N N 1 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (VenteId) Second Floor 30 Blown 949 ft2 0.11 Wood 11/20/2018 8:08 AM Ene gyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FnR1VI'R405-2017 INPl1T SU MARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space _ 1 S Exterior Concrete Block - Int InsrI I First Floor 4.1 28 4 10 0 283.3 ftz 0 0.2 0 _ 2 W Exterior Concrete Block - Int InZ First Floor 4.1 13 7 10 0 135.8 ftz 0 0.2 0 3 E Exterior Concrete Block - Int InIl First Floor 4.1 24 0 10 0 240.0 ftz 0 0.2 0 _ 4 S Exterior Concrete Block - Int InstSecond Floor 4.1 35 8 8 0 285.3 ftz 0 0.2 0 _ 5 E Exterior Concrete Block - Int I siSecond Floor 4.1 24 4 8 0 194.7 ft2 0 0.2 0 6 W Exterior Concrete Block - Int I s6Second Floor 4.1 24 4 8 0 194.7 ftz 0 0.2 0 7 W Garage Frame - Steel First Floor 13 10 0 10 0 100.0 ftz 0.1 0.2 0 DOORS # Ornt Door Type I Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated I First Floor None .46 3 6 8 20 ftz WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 1 Metal Single (Clea) Yes 1.01 0.48 Y 40.0 ftz 1 ft 8 in 2 ft 0 in Drapes/blinds None 2 W 2 Metal Single (Cle r) Yes 1.1 0.39 Y 30.0 ftz 7 ft 4 in 2 ft 0 in Drapes/blinds None 3 E 3 Metal Single (Clesr) Yes 1.1 0.39 Y 60.0 ftz 1 ft 8 in 2 ft 0 in Drapes/blinds None 4 S 4 Metal Single (Clef r) Yes 1.1 0.39 Y 16.7 ftz 1 ft 8 in 2 ft 0 in Drapes/blinds None 5 E 5 Metal Single (CIar) Yes 1.1 0.39 Y 30.0 ftz 1 ft 8 in 2 ft 0 in Drapes/blinds None 6 W 6 Metal Single (Cl ar) Yes 1.1 0.39 Y 23.3 ftz 1 ft 8 in 2 ft 0 in Drapes/blinds None 7 W 6 Metal Single (Tited) Yes 1.1 0.39 Y 30.0 ftz 1 ft 8 in 2 ft 0 in Drapes/blinds None I GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 200 ftz 200 ftz 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 4 Wholehouse Proposed ACH(50) 000293 1203.3 66.06 124.23 .1391 5.246 I HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat I None COP:1 19.7 kBtu/hr 1 sys#1 11/20/2018 8:08 AM Energ'yGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FntQnn IQAnr,_7ni7 IKIPI IT CI IMMARV r:HFC.KI_IRT RFPORT - - - -- -- - - - - -- I COOLING SYSTEM # System Type SuWpe Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16.5 35 kBtu/hr 1200 cfm 0.75 1 sys#1 I HOT WATER SYSTEM - # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Heat Pump arage 3.690654 50 gal 50 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # V/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 85 ft2 Attic 25 ft2 Default Leakage Second Flo (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Coolie [[ ]] Jan [[ ]] Feb Heating [X] Jan [X] Feb Mar Mar A r APr [ [ j May [X] Jun X Jul ]May ] Jun Jul Au 4 Aug Sep rl Se [ ]Oct [ ] Oct Nov Nov Dec Dec Ventin [[ ]] Jan [[ ]] Feb X X Mar [X) A r [ ] Ma ] Jun Jul E [ Au Se [X] Oct X Nov Dec Thermostat Schedule: HERS 2006 Referenda Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. I 0 ft2 0 ft 0.3 First Floor Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Second Floor 11/20/2018 8:08 AM EhergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 Buildir�I Input Summary Report I PROJECT Title: Unit B West Facing I Address type: S Building Type: User Bedrooms: 3 Lot #: Owner: Oleander Properties Dixieland LL P Conditioned Area: 1566 Block/SubDivision: Total Stories: 2 PlatBook: Builder Name: Southern City Development Worst Case: No Street: 257-259 Dixieland Drive Permit Office: St. Lucie County Bldg Division Rotate Angle: 0 County: St. Lucie Jurisdiction: Planning/Dev. Servic Cross Ventilation: City, State, Zip: Ft. Pierce, Family Type: Multi -family Whole House Fan: FL, 34982 New/Existing: New (From Plans) Terrain: Urban Year Construct: 2018 Shielding: Urban Comment: CLIMATE Design Design Temp Int Design Temp Heating Design Daily temp V Location TmI Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERC>_BEACH_MUNICIPA 39 90 I 70 75 299 62 Low I UTILITY Fuel Unit Utility Name Monthly Fixed Cost $/Unit Electricity kWh Florida Av�rage 0.00 0.12 _ Natural Gas Therm Florida A4rage 0.00 1.72 Fuel Oil Gallon Florida Default 0.00 1.10 _ Propane Gallon Florida Default 0.00 3.13 I SURROUNDINGS ------------Shade Trees -------------- ----------Adjacent Buildings---------- Ornt Type Height Width Distance Exist Height Width Distance N None Oft Oft Oft Oft Oft Oft NE None Oft Oft Oft Oft Oft Oft E None Oft Oft Oft Oft Oft Oft SE None Oft Oft Oft Oft Oft Oft S None Oft Oft Oft Oft Oft Oft .SW None Oft Oft Oft Oft Oft Oft W None Oft Oft Oft Oft Oft Oft NW None Oft Oft Oft Oft Oft Oft BLOCKS Number Name Area Volume _ 1 Blockl I 1566 13762 I SPACES Number Name I Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated —1 First Floor 617 6170 Yes 0 0 Yes Yes Yes 2 Second Floor 949 7592 No 3 3 Yes Yes Yes 11/20/2018 8:09:36 AM I EnergyGauge®/ USRCSB v6.1 Page 1 Building Input Summary Report I FLOORS (Total Exposed Area = 617 sq.ft.) # Floor Type Space I Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet _ 1 Slab -On -Grade Edge Ins First Floo� 132 0 617 it 0.304 --- 0 0 1 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V# Type Mated s Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1000 ft2 0 ft2 Light N 0.75 No 0.9 No 0 18.4 I ATTIC # Type Jentilatlon Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 949 ft2 N N CEILING (Total Exposed Area = 949 sq.ft.) # Ceiling Type Space R-Value Ins. Type Area U-Factor Framing Frac. Truss Type -1 Under Attic(Vented) Second Floor 30.0 Blown 949.0ft2 0.055 0.11 Wood WALLS (Total Exposed Area = 1434 sq.ft.) Adjacent Cavity Width Height Area U- Sheath Frm. Solar Below ✓# Omt To Wall Type Space R-Value Ft In Ft In sq.ft. Factor R-Value Frac. Absor. Grade _ 1 S Exterior Conc. Blk - ant Ins First Floor 4.1 28.0 4 10.0 0 283.3 0.149 0 0.2 0 % _ 2 W Exterior Conc. Blk - Int Ins First Floor 4.1 13.0 7 10.0 0 135.8 0.149 0 0.2 0 % _ 3 E Exterior Conc. Blk Int Ins First Floor 4.1 24.0 0 10.0 0 240.0 0.149 0 0.2 0 % _ 4 S Exterior Conc. Blk - Int Ins Second Floor 4.1 35.0 8 8.0 0 285.3 0.149 0 0.2 0 % 5 E Exterior Conc. BlkInt Ins Second Floor 4.1 24.0 4 8.0 0 194.7 0.149 0 0.2 0'/0 _ 6 W Exterior Conc. Blk - Int Ins Second Floor 4.1 24.0 4 8.0 0 194.7 0.149 0 0.2 0 % 7 W Garage Frame - Steel First Floor 13.0 10.0 0 10.0 0 100.0 0.162 0.1 0.2 0 % DOORS (Total Exposed Area = 20 sq.ft.) Width Height V. # Ornt Adjacent To Doo Type Space Storms U-Value Ft In Ft In Area 1 W Exterior In ulated First Floor None 0.46 3.00 0 6.00 8 20.0ftz WINDOWS (Total Exposed Area = 230 sq.ft.) Wall ✓# Ornt ID Frame I Panes NFRC U-Factor SHGC Imp Storm, Area ----- Overhang ----- Depth Separation Interior Shade Screening 1 S 1 Metal Single (Clear) Yes 1.01 0.48 Y N 40.0ft2 1.0 it 8 in 2.0 it 0 in Drapes/blinds None 2 W 2 Metal Singe (Clear) Yes 1.10 0.39 Y N 30.0ft2 7.0 it in 2.0 it in Drapes/blinds None 3 E 3 Metal Single (Clear) Yes 1.10 0.39 Y N 60.0ft2 1.0 it 8 in 2.0 it 0 in Drapes/blinds None -4 S 4 Metal Single (Clear) Yes 1.10 0.39 Y N 16.7ft2 1.0 it 8 in 2.0 it 0 in Drapes/blinds None -5 E 5 Metal Single (Clear) Yes 1.10 0.39 Y N 30.Oft2 1.0 it 8 in 2.0 it 0 in Drapes/blinds None -6 W 6 Metal Sin' le (Clear) Yes 1.10 0.39 Y N 23.3ft2 1.0 it 8 in 2.0 it 0 in Drapes/blinds None 7 W 6 Metal Sin le (Tinted) Yes 1.10 0.39 Y N 30.0ft2 1.0 it 8 in 2.0 it 0 in Drapes/blinds None 11/20/2018 8:09:36 AM I EnergyGauge® / USRCSB v6.1 Page 2 Buildi 7g Input Summary Report INFILTRATION # Scope Method S'L/A CFM50 ELA EgLA ACH ACH50 Space(s) 1 Wholehouse Proposed ACH(50) 0.00029 1203 66.06 124.23 0.1391 5.2 All GARAGE # Floor Area '' Roof AI ea Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 200 ft2 200Ift2 64 ft 8 ft 1 MASS # Mass Type I Area Thickness Furniture Fraction Space _ 1 Default(8 Ibs/sq.ft.) 2 Default(8 Ibs/sq.ft.) 0 ft2 0 ft2 0 ft 0.30 First Floor 0 ft 0.30 Second Floor HEATING SYSTEM # System Type S/1btype AHRI # Efficiency Capacity ----Geothermal HeatPump---- Ducts Block kBtu/hr Entry Power Volt Current 1 Electric Strip Heat None COP: 1.00 19.7 0.00 0.00 0.00 sys#1 1 f COOLING SYSTEM # System Type Subtype AHRI # Efficiency Capacity Air Flow SHR Duct Block kBtu/hr cfm 1 Central Unit Split SEER:16.5 35.0 1200 0.75 sys#1 1 HOT WATER SYSTEM # System Type Subtype I Location EF(UEF) Cap Use 'SetPnt Fixture Flow Pipe Ins. Pipe length 1 Electric Heat Pump Garage 3.69 (3.55) 50.00 gal 50 gal 120 deg Standard None 74 Recirculation Recirc1,Control System T pe i Loop Branch Pump DWHR Facilities Equal DWHR Other Credits length length power Connected Flow Eff 1 No I NA NA NA No NA NA NA None DUCTS Duct---------Supply------------------Return--------- Air CFM 25 CFM 25 HVAC # # Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT QN RLF Heat Cool _ 1 Attic 6.0 15 ft2 Attic 6.0 25 ft2 Default Leakage Second Flo (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: YI Cooling [ ] Jan [ ] Feb Heating [X] Jan [X] F4eb Venting [ ] Jan [ ] iWleb (] Mar [ ] Apr [Xj Mar [ ] Apr [X] Mar [X] Apr Ceiling Fans: N [ ] May [X] Jun, [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] May [ ] Jun []Jul [ ] Aug [ ] Sep [ ] Oct [X] Nov [X] Dec [ ] May [ ] Jun []Jul [ ] Aug [ ] Sep [X] Oct [X] Nov [] Dec 11/20/2018 8:09:36 A EnergyGauge® / USRCSB v6.1 Page 3 Buildi 7 g Input Summary Report TEMPERATURES(Continued) Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 781 78 78 78 78 78 78 80 80 80 80 _ PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 76 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 6B 8 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MISC ELECTRICAL LOADS ID Type Screen I Location Item Quantity Catagory Operating Schedule Off Standby _ 1 Misc Elec Load Simple Default I Main 1 1 HERS2011 1 APPLIANCES & LIGHTING SCHEDULES Appliance Schedule: HERS2014 Hours Schedule Type 1 I 2 3 4 5 6 7 8 9 10 11 12 Occupancypeak: 400 Btu AM I 0.930 0.930 0.930 0.930 0.930 0.930 0.930 0.980 0.460 0.270 0.270 0.270 % Released: 100 % PM 0.270 0.270 0.270 0.270 0.330 0.610 1.000 1.000 0.930 0.930 0.930 0.930 refrig peak: 0 W AM 0.824 0.804 0.784 0.764 0.744 0.734 0.744 0.754 0.764 0.794 0.814 0.854 % Released: 100 % PM 0.$54 0.864 0.884 0.904 0.925 0.945 0.925 0.915 0.904 0.894 0.874 0.854 calash peak: 0 W AM0_rr(I200 0.100 0.050 0.050 0.050 0.075 0.200 0.375 0.500 0.800 0.950 1.000 % Released: 30 % PM 0.875 0.850 0.800 0.625 0.625 0.600 0.575 0.550 0.625 0.700 0.650 0.375 E-cDry peak: 0 W AM .200 0.100 0.050 0.050 0.050 0.075 0.200 0.375 0.500 0.800 0.950 1.000 % Released: 15 % PM 0.875 0.850 0.800 0.625 0.625 0.600 0.575 0.550 0.625 0.700 0.650 0.375 dWash peak: 0 W AM 0.139 0.050 0.028 0.024 0.029 0.090 0.169 0.303 0.541 0.594 0.502 0.443 "% Released: 60 % PM 0.376 0.396 0.334 0.323 0.344 0.448 0.791 1.000 0.800 0.597 0.383 0.281 E-rOven peak: 0 W AM 0.057 0.057 0.057 0.057 0.057 0.114 0.171 0.286 0.343 0.343 0.343 0.400 % Released: 80 % PM 0.457 0.343 0.286 0.400 0.571 1.000 0.857 0.429 0.286 0.229 0.171 0.114 TVs peak: 226 W AM 0.100 0.050 0.050 0.050 0.100 0.200 0.400 0.450 0.400 0.200 0.100 0.100 Released: 100 % Pry 0.050 0.050 0.150 0.450 0.850 1.000 0.950 0.800 0.500 0.250 0.150 0.100 cFan peak: 0 W AM 0.600 0.600 0.600 0.600 0.600 0.600 0.600 0.250 0.250 0.250 0.250 0.250 % Released: 100 % PM 0.250 0.250 0.250 0.250 0.250 0.250 0.550 0.600 0.600 0.600 0.600 0.600 Igts-in peak: 0 W L 0.160 0.150 0.160 0.180 0.230 0.450 0.420 0.260 0.190 0.160 0.120 0.110 % Released: 100 % bM 0.160 0.170 0.250 0.270 0.340 0.550 0.600 0.880 1.000 0.880 0.510 0.280 Igts-out peak: 0 W AM 1.000 1.000 1.000 1.000 1.000 0.750 0.750 0.000 0.000 0.000 0.000 0.000 % Released: 0 % PM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.500 0.750 0.750 0.750 1.000 Igts-gar peak: 0 W AM 0.000 0.000 0.000 0.000 0.000 0.500 0.750 1.000 0.750 0.500 0.000 0.000 % Released: 0 % PM 0.000 0.000 0.500 0.500 0.750 1.000 0.750 0.500 0.000 0.000 0.000 0.000 MEL peak: 0 W AM 0.500 0.500 0.500 0.750 0.750 0.850 1.000 1.000 1.000 1.000 0.900 0.900 % Released: 90 % PM 0.900 0.900 1.000 1.000 1.000 1.000 1.000 1.000 1.000 0.850 0.750 0.750 11/20/2018 8:09:36 AM EnergyGauge® / USRCSB v6.1 Page 4 v 2617 EPL DISPLAY CARD ENERGY PER ESTIM The lower the 1. New home or, addition r 2. Single-family or multiple -family 3. No. of units (if multiple -family) 4. Number of bedrooms 5. Is this a worst case? (yes/no) 6. Conditioned floor area (sq. ft.) 7. Windows, type and area a) U-factor:(weighted a b) Solar Heat Gain Coe c) Area 8. Skylights a) U-factor:(weighted b) Solar Heat Gain C 9. Floor type, insulation level: a) Slab -on -grade (R-value b) Wood, raised (R-valuejj c) Concrete, raised (R-val 10. Wall type and insulatic A. Exterior: 1. Wood frame (Insula 2. Masonry (Insulation B. Adjacent: 1. Wood frame (Insula 2. Masonry (Insulation RMANCE LEVEL (EPL) DISPLAY CARD ;D ENERGY PERFORMANCE INDEX* = 92 Performance Index, the more efficient the home. 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Multi -family b) Return ducts R 6.0 c) AHU location Second Floor 3. 1 4. 3 13. Cooling system: Capacity 35.0 a) Split system SEER 16.5 5. No b) Single package SEER c) Ground/water source SEER/COP 6. 1566 d) Room unit/PTAC EER e) Other 7a. 1.084 (SHGC) 7b. 0.406 14. Heating system: Capacity 19.7 7c. 230.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 8a. NA d) Gas furnace, natural gas AFUE (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other i 9a. 0.0 9b. 15. Water heating system ie) 9c. a) Electric resistance EF 3.69 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF R-value) 10A1. e) Dedicated heat pump with tank EF alue) 10A2. 4.1 f) Heat recovery unit HeatRec% g) Other ion R-value) R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 10131. 13.0 1062. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11 a. 30.0 b) Cross ventilation No 11 b. c) Whole house fan No 11c. d) Multizone cooling credit 11 d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Sdetion R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, anew EPL display card will be completed based on installed code compliant features. Builder Date: Address of New Home: 257-259 Dixieland Drive City/FL Zip: Ft. Pierce, FL 34982 11/20/2018 8:09:05 AM/ EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Air System Sizing Summary for Unit A ,B1 Project Name: Dixieland Townhomes 06/01/201 10:53AI Air System Information Air System Name ......................................................... Unit ,B1 Number of zones.----------.....------•-•-----..............................-----............----1 Equipment Class......................................................... --------•---------------•- .....................---- SPLTJAHU Floor Area ........................ ............................................................. 1654.0 ft2 Air System Type..............................-------........................... SZCAV Location............................................................. Fort Pierce, Florida Sizing Calculation Information Zone and Space Sizing Method: Zone CFM.................................. Sum of space airflo rates Calculation Months.......................................................... Jan to Dec Space CFM ............................. Individual peak space loads Sizing Data ................................................................ Calculated Central Cooling Coil Sizing Data Total coil load---...-------------------••----...............-------...................2.9 Tons Load occurs at--------------------................•----............................ Jun 1600 Total coil load ...................................... ---......------......---.I-----.....35.3 MBH OADB/WB._.....-•--•---------------------------.....----....................90.5176.9 OF Sensible coil load ......................................................... 1....-------30.8 MBH Entering DB / WB............................................................. 73.0 / 59.2 OF Coil CFM at Jun 1600 .................................. - -1200 CFM Leaving DB / WB----........................-----•-........................49.2 / 48.0 OF Maxblock CFM....---••-...................................... - - - ..........1200 CFM Coil ADP.-------------------------------.............---------......----------............. 46.6 OF Sum of peak zone CFM--•--------------------..............................1200 CFM Bypass Factor ............................................................................... 0.100 Sensible heat ratio--- ........................... ...................... ............. 0.873 Resulting RH-------------------..................--------------------------.................44 % ft2rron.....................-------..............----------------------....................562.2 Design supply temp ...................................................................... 47.5 OF BTU/(hr-ft-)................•--------------------------•-............................. 21.3 Zone T-stat Check------------------------...........------............-----......... 0 of 1 OK Water flow @ 10.0 OF rise ..................................................... NIA Max zone temperature deviation ................................................. 0.0 OF Central Heating Coil Sizing Data Maxcoil load ............................................... ......... ...................... 14.3 MBH Load occurs at ..................... .................................................... Des Htg CoilCFM at Des Htg......--....................................................1200 CFM BTU/(hr-ft2).-----•------------------...-------...------...........-•.----.......................8.7 Max coil CFM......................... '........................... I ...................... 1200 CFM Ent. DB / Lvg DB............................................................... 69.7 / 80.8 OF Water flow @ 20.0 OF drop .---------- .............................-----.. NIA Supply Fan Sizing Data Actual max CFM ................................................ ...........................1200 CFM Fan motor BHP -------------- --------------------------------......--------............. 0.17 BHP Standard CFM............ .................................. ............................ 1198 CFM Fan motor kW...........----------------.....----..........................---............ 0.13 kW Actualmax CFM/ft2-------------------•--........................................... 0.73 CFM/ftZ Fan static..... ----------------------------------........----.....................-.......... 0.50 in wg Outdoor Ventilation Air Data Design airflow CFM..................................----............................... 0 CFM CFM/person-----------------------........................................-..................0.00 CFM/person CFM/n2....................................................... ..................................0.00 CFM/ft2 =ECEED \\\��,, i l l ►, �,,��� r � 71 o��; N. I •fie Hourly Analysis Prograrp v.4.2 Page 1 of 1 [Project Name: Dbdeland Townhomes Air Sizing Summary for Unit B2 06/01/201 10:59AI Air System Information Air System Name ............................................... ................ U it B2 Number of zones.....................-•-•--........---------------------.........-•--------.....1 Equipment Class .--------------------- ................................ SPLTIAHU Floor Area ..................................................................................... 1654.0 ft' Air System Type---.........................•............•.................. SZCAV Location ............................................................. Fort Pierce, Florida Sizing Calculation, Information Zone and Space Sizing Method: Zone CFM.................................. Sum of space airflo rates Calculation Months .............................. _.......................... Jan to Dec Space CFM ............................. Individual peak spac loads Sizing Data ......................................................................... Calculated Central Cooling Coil Sizing Data Total coil load .................................................. ...... 2.5 Tons Load occurs at.......-------...............................--......--------........Jul 1700 Total coil load.......................................................................... 29.6 MBH OA DB / WB.....................---------------------..............................90.5 / 76.6 °F Sensible coil load ................................................................ ......25.6 MBH Entering DB / WB....................... -............ ........................ 73.0159.4 OF Coil CFM at Jul 1700----------------•-•.................---......-..........1000 CFM Leaving DB / WB............................................................... 49.3 / 48.0 OF Maxblock CFM--...........:.....•-•-••---.-_.-------------......................1000 CFM Coil ADP------------------------.......--.•.-•-----•--------------------------................. 46.6 OF Sum of peak zone CFM.................................................. ...... 1000 CFM Bypass Factor ............................................................................... 0.100 Sensible heat ratio ................................................... ......... ..... 0.865 Resulting RH----...---------------------_.............-------•----------.....................44 % ft'/Ton........................_............................................--................. 669.5 Design supply temp ...................................................................... 47.7 OF BTU/(hr-ft')..------••-------•-------------................................................17.9 Zone T-stat Check ...................................................................... 0 of 1 OK Water flow @ 10.0 OF rise ..................................................... WA Max zone temperature deviation ................................................. 0.0 OF Central Heating Coil Sizing Data " Maxcoil load................•-•-•-----------------.......................... ---.......10.2 MBH Load occurs at ......................................................................... Des Htg Coil CFM at Des Htg............................................................. 1000 CFM BTU/(hr-ft').......................................................................................... 6.2 Max coil CFM---•---..........................•-•----•----.............................1000 CFM Ent. DB / Lvg DB............................................................... 69.9 / 79.3 OF Water flow @ 20.0 OF drop ............ . .................................... NIA Supply Fan Sizing Data Actual max CFM .......................................................... ............1000 CFM Fan motor BHP ............................................................................... 0.15 BHP StandardCFM....................................................-............-------- 999 CFM Fan motor kW-------•--------------•-----------................................................ 0.11 kW Actual max CFM/ft'................................................... .............. 0.60 CFM/ft' Fan static ........................................................................................... 0.50 in wg Outdoor Ventilation Air Data Design airflow CFM---....................................•----......................... 0 CFM CFM/person............................................---...............•----..................0.00 CFM/person CFM/ft'...................................--------.....------------...........................0.00 CFM/ft' \\\\��l►IIIII q l AF oR/D Hourly Analysis Program v.4.2 I Page 1 of 1