HomeMy WebLinkAboutBUILDING PLAN PAGE 1-16FIVE-V GALVANIZED METAL ROOF BY 'GULF COAST METAL ROOFING' OR EQUAL INSTALLED PER MF'G SPECIFCATIONS GALVANIZED 6" HALF ROUND GUTTERS BY GALVANIZED 3" ROUND DOWNSPOUTS BY PAINTED PT PINE BRACKET -COORDINATE LOCATION OF RAFTERS 11 2x6 PT PINE FASCIA OVER 2x4 PT SUB- FASCIA- SEE DETAILS HARDY CEMENTIOUS BOARD SIDING (5" 6� EXPOSED) OVER 1x3 PT GROUNDS TAP - CON INTO CMU WALLS 1 1/4" THICK PAINTED PT TRIM BOARDS AT CORNERS TO RECEIVE HARDY BOARDS PAINTED PT TRIM WATER TABLE -SEE DETAILS 1 AT SHEET A-5.0 SMOOTH PAINTED STUCCO FINISH SMOOTH PAINTED STUCCO WATER TABLE �. 10 COORDINATE WITH WINDOWS WHERE APPL 11 STAINLESS CHIMNEY FLUE -SUPPORT WITH STAINLESS TURNBUCKLES & WIRE LINES ilk _ h -F=IT. 12 PRE-MF'G PVC RAILING CAPS AND BALLASTERS 4 PAINTING OF THIS MATERIAL TBD 13 R-30 BATT INSULATION 14 PRE -MANUFACTURED WOOD TRUSSES AT 24" OC DESIGN FOR 175mph WINDS-2x6 TOP & BOTTOM 5 CORDS 6 15 1x6 T&G PINE PANELING PAINTED -OWNER TO DETERMINE EXTENT 13 16 PAINTED PINE PANELING -OWNER TO DETERMINE EXTENT IN LIEU OF DW 17 ATTENTION TO SHEAR WALL STEEL PLACEMENT IN THESE AREAS -REFER TO STRUCTURAL'' - F-• 1 BY OWNER I I II II � I f TYPICAL RETENTION SWALE , GARAGE LEVEL ' m 12' MIN SLOPED C STAIRCASE DETAILS A4 SCALE:3/16"=1'-0" REFER TO STRUCTURAL FOR FOUNDATION DESIGN 12' MIN /00'�ASECTION A4/ SCALE : 3/ 16"=1'-0" g SECTION A4 SCALE:3/16"=1'-0" GRADE AT EDGE OF HOUSE 8" MIN ABOVE TOP OF FOOTING IE EXTEND _L FINISH TOP OF FOOTING wmarthur ARCHITECT OF RECORD William F. Arthur AR-0012074 L Co U � >� n3 s i t �O Q � = M � � M Z3 •X i O QC 7 L.L.E t0 Q) r O U = N N c N IL 0" ON `T �t 01 O- M M c6 rB O O O '} ^u W W �s M c t6 IM U c z a) o as o 0 m c LM c c U Z Q u W iu 06 o O 00 OI ca0 O aC"� ZO0N Z SECTIONS/ DETAILS PRINTED March 5, 2021 .m WATCH GALLERY PERSPECTIVE VIEW FROM SOUTH WEST Modern elegance Description ----_.. The Jetul GF 370 DV IPI utilizes modern design and the new JotulBurner III to create an exceptional fire view from any angle. Loaded with standard features including accent lighting, variable speed blower and energy saving ignition system, the Jetul GF 370 DV is the perfect combination of design and. craftsmanship. Popular options include Black Reflective Glass Panel Kit. • Standard features include Choice of required media accent lighting, variable include: Traditional Logs, speed blower and energy River Rocks, Tumbled saving ignition system Stones, Black Glass, and White Starfire Glass + Multifunction Proflame 2 remote with flame control S:a Height: 45.5 in Width: 18.25 in Depth: 18.75 in Colors — • M 3rd LEVEL LOOKING OVER BALCO p SECTION VIEW A5 SCALE:3/8"=1'-O" E SECTION A5 SCALE:1"=1'-O" VC OR WOOD SILL MATERIAL VC OR WnOn RA(;FRnARr) RFI ECO WINDOW SYSTEMS REFER TO PROJECT BOOKLET FOR NOA's PVC TRIM AROUND CONC COLUMN PVC SILL 8" U-BLOCK W/ (2) #5 AND #5 HOOKS FROM SLAB @ 32" OC SMOOTH HARDY BOARD 31DING ON 1x3 PT FURRING STRIPS @ 18" OC WATER TABLE TRIM FROM PVC PVC TRIM BOARD .V. sArnnn nnnr C ELEVATION VIEW A5 SCALE:3/8"=1'-0" I MATERIAL SELECTION BY OWNER i 71 8x8 CONC W/ (4)#5 V AND #3 HC 12" OC COLUMN RTICAL OPS AT - . tN e 13'-8" B PLAN VIEW A5 SCALE:3/8"=1'-0" A 3rd LEVEL WINDOW DETAIL \5 SCALE:3/8"=1'-O" 3 wmarthur ARCHITECT OF RECORD William F. Arthur AR-0012074 \m i--s U r6 S i � a .� S M L rM X O <( LL E � N b O U — N � G OS O� d' co i O i O `~ IL c> > L m a) N U M (n C S to U ro r6 U Z CO a) W 0 aJ a)U z c U U C U Q C QuJ d SC Lu d O 00 O N O aCLN ZOI0N SECTIONS/ DETAIL' PRINTED March 5, 2021 A-5.0 GENERAL STRUCTURAL NOTES 1. DESIGN CRITERIA: THE FBC 7th EDITION 2020 A. SUPER IMPOSED DEAD LOADS: 1. MAIN FLOOR AND STAIRS as 75psf 2. ROOF = 20psf B. DESIGN LIVE LOADS PER TABLE R301.5 BELOW. TABLE R301.5 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS (In pounds persquare toot) USE LIVELOAD Uninhabitable attics without storage" 10 Uninhabitable attics with limited storageb, a 20 Habitable atfics and attics served whh geed stairs 30 Balconies (exterior) and decks' 40 Fire escapes 40 Guerde and harldreAes 200b Guard In -fill oomponemsf 50h Passenger vehicle garegess 50s Rooms other than sleeping rooms 40 Sleeping rooms 30 Stairs 400 C. WIND LOADS: ASCE 7-10 BASIC WIND SPEED V=165mph RISK FACTOR 1-1.6 EXPOSURE CATEGORY=D INTERNAL PRESSURE COEFFICIENT GCpi=0.18 Kd (DIRECTIONAL FACTOR) = 0.85 130 SSe wind-bDine Debris Reoinn 14 Gas ' +. ODeugnattde,taswbxamebesltwintl3paed a� - 156 i5Z,no110rgreato. aaaaw.,as 130MPHandwtthim1m11eof Neowq 150 fiat..: a - 1. values are ulCima assign 3-.mvw g..i vial apaMe in six. ,at trout WS) at 33 160 ' It (i. aosvo woos Los sits. C eat- _ 2. Linear ins.=PPlatia bet.asn antootc 170 1.pataitead. « 3. isi.ou andas.t.1 nt..a outside tot last cost. .ball uan eha lsae r1M aPeaA aocP.r of t3re a»atal ataa. 180 4.-ia:mr.imu. t=rydn. gaz ,ocean 180 ptaisoosis., sm epaciai vital tegiass shall be ermined tar ,mieu.1 was tad- tiPn.. 5. wim spa . co ,ons to ap isatasy a n P-pity,w . a aeadanta in .o year. (annual 0rcteda,ce Probability= 0.00143, Mt - toh year.). a �' 6. 141s map is aerate to the cwmty. 3.ca1 gsva.ta establish ,gacllie ln4 msedr'/ine-mme debris isms. unins pbysiW lavdmerks 6uch a0 miler stills, canal.: rival am Bbat.ilnN. FIGURE R301.2(4) ULTIMATE DESIGN WIND SPEEDS Vdg 2. FOUNDATIONS: A. THE ARCHITECT HAS VISITED THE SITE AND CONFIRMS THE EXISTING SOIL BEARING TO BE 2500psf. REFER TO SOIL BEARING TEST BY TEDERAL ENGINEERING' CONTAINED HEREIN. B. TOPSOIL AND ALL ORGANIC, DELETERIOUS MATERIAL SHALL BE COMPLETELY REMOVED AT LEAST FIVE FEET BEYOND THE EXTERIOR OF EACH BUILDING. CLEAN WELL GRADED MATERIALS SHALL BE USED FOR BACK FILL INSTALLED PER TEDERAL ENGINEERING RECOMMENDATIONS. SEE RECOMMEDATIONS CONTAINED HEREIN. 3. STRUCTURAL STEEL: A. SHALL CONFORM TO ASTM DESIGNATIONS A-36, A-325, A-500 AS APPLICABLE AND ANSC-360 SPECIFICATIONS FOR DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS. BOLTS AND WELDING MATERIALS SHALL BE STAINLESS STEEL. B. FIELD CONNECTIONS SHALL BE WELDED OR BOLTED AS SPECIFIED OR WHERE FIELD WELDING IS REQUIRED SHALL BE CERTIFIED WELDERS ONLY. C. THE FABRICATOR SHALL SUBMIT SHOP DRAWINGS FOR REVIEW AND ACCEPTANCE PRIOR TO FABRICATION. D. ANCHOR BOLTS SHALL BE SIZED TO PROVIDE A MINIMUM OF 8" EMBEDMENT INTO FOOTINGS WHERE APPLICABLE. 4. CONCRETE: A. ALL CONCRETE UNLESS OTHERWISE NOTED: fc=4000psi (5 BAGS PER YARD MIN., #57 COARSE AGGRIGATE) B. CONCRETE STRUCTURAL BEAMS SHALL BE AS FOLLOWS: fc-5000psi (PUMP MIX W/ P-GRAVEL AGGRIGATE) UNDER NO CIRCUMSTANCES SHALL WATER BE ADDED TO THE MIX WITHOUT THE EXPRESS CONSENT OF THE ARCHITECT WHEN PRESENT ON THE JOB. C. SUBMIT MIX DESIGN TO ARCHITECT FOR ACCEPTANCE PRIOR TO CONCRETE PLACEMENT, D. CONCRETE EXPOSED TO WEATHER SHALL HAVE A MAXIMUM 0.40 WATER/ CEMENT RATIO AND A CORROSION ADMIXTURE. E. NON-METALLIC, NON -SHRINK GROUT SHALL BE 7000psi COMPLYING WITH CE-CRD-C621. S. CONCRETE CONSTRUCTION: A. ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH AMERICAN CONCRETE INSTITUTE STANDARD; "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" (ACI 318-08), STRENGTH DESIGN METHOD. B. CONCRETE COVER: 1. FOOTING AND PADS PLACED AGAINST THE GROUND 3". 2. CONCRETE SURFACE AFTER REMOVAL OF FORMS EXPOSED TO WEATHER OR GROUND: No. 5 OR SMALLER 1 1/2" No. 6 OR LARGER 2" 3. CONCRETE NOT EXPOSED TO WEATHER OR GROUND (UNLESS OTHERWISE SPECIFIED ON THE DRAWINGS OR THE CALCULATIONS): SLABS AND WALLS 3/4" BEAMS AND GIRDER TIES 1 1/2" COLUMN TIES 1 1/2" 6. REINFORCING STEEL: /;. REINFORCING STEEL SHALL BE NEW BILLET BARS CONFORMING TO: ASTM A-615, GRADE 60 (#3 THRU #11), fy=60,000psi. B, ALL TERMINATING TOP REINFORCING BARS SHALL END WITH A HOOK 7. DETAILING AND FABRICATION OF REINFORCING: A, UNLESS OTHERWISE NOTED, DETAILING SHALL FOLLOW ACI-315 STANDARDS. S. SUBMIT SHOP DRAWINGS FOR REVIEW AND ACCEPTANCE PRIOR TO FABRICATION. 8. PLACING AND SUPPORTS OF REINFORCING BARS: A. FOLLOW CRSI "RECOMMENDED PRACTICE FOR PLACING REINFORCING BARS, INCLUDING 1983 SUPPLEMENT" AND ACI-315. 9. CORNER BARS: A. PROVIDE T-0"x T-0" CORNER BARS AT CORNERS OF BEAMS AND WALLS, MATCHING DIAMETER AND AMOUNT AT EACH HORIZONTAL LAYER OF REINFORCING. 1o. CURING COMPOUNDS: A. PROVIDE CURING COMPOUND FOR ALL SLABS; 'AQUA KURE' BY LAMBERT CORPORATION OR ACCEPTED EQUAL. 11. CONCRETE MASONRY UNITS: A. THE LOAD BEARING MASONRY WALLS ARE DESIGNED IN ACCORDANCE WITH THE SPECIFICATIONS FOR THE DESIGN AND CONSTRUCTION OF LOAD BEARING CONCRETE MASONRY BY THE NATIONAL CONCRETE MASONRY ASSOCIATION AND FBC REQUIREMENTS FOR CONCRETE MASONRY STRUCTURES- ACI 530-08, ASCE 5 AND TMS 402. B. MINIMUM COMPRESSIVE STRENGTH OF LOAD BEARING MASONRY UNITS SHALL BE 1900psi (ASTM C90-90, GRADE N). MASONRY CEMENT (MORTAR) SHALL COMPLY WITH ASTM C91 AND SHALL ACHIEVE A MINIMUM COMPRESSIVE STRENGTH OF 2500psi (ASTM C270, TYPE M). C. MASONRY SHALL BE PLACED PRIOR TO PLACING CONCRETE COLUMNS. D. ALTERNATE HORIZONTAL JOISTS SHALL BE REINFORCED W/ #9 GAUGE GALVANIZED LADDER TYPE REINFORCING CONFORMING TO ASTM A82 CONTINUOUS IN ALL 8" CONCRETE MASONRY WALLS. THESE SHALL LAP INTO THE CONCRETE COLUMNS. E, AT ALL WALL ENDS, INTERSECTIONS, CORNERS AND ON EACH SIDE OF WALL OPENINGS, IF A COLUMN IS NOT SHOWN, PROVIDE VERTICAL REINFORCING AS CALLED OUT ON PLAN AND GROUT THE REINFORCED CELL OF THE BLOCK. USE DOWELS AND MAINTAIN CONTINUITY WITH THE STRUCTURE ABOVE. TERMINATE BAR WITH A STANDARD HOOK INSIDE THE CONCRETE BEAM AT TOP OF WALL. F. PROVIDE CLEAN OUT OPENINGS FOR EACH GROUTED CELL. G. SUBMIT CERTIFICATION OF COMPLIANCE WITH ASTM SPECIFICATIONS FOR THE CMU, MASONRY CEMENT AND REINFORCING PRIOR TO DELIVERY TOT HE SITE. H. ALL LAP SPLICES SHALL BE 48 BAR DIAMETER. I, PROVIDE COOURSE GROUT IN ACCORDANCE W/ ASTM C476 fc=2500 psi, 8" SLUMP. 12. OPENINGS IN STRUCTURAL MEMBERS: A, HOLES AND OPENINGS REQUIRED ARE SHOWN ON THESE DRAWINGS B. NO OTHER OPENINGS OR HOLES IN ANY STRUCTURAL MEMBER ARE PERMITTED WITHOUT WRITTEN AUTHORIZATION FROM THE ARCHITECT. C. ALL ROUGH OPENINGS AROUND OR AFFECTED BY MECHANICAL, ELECTRICAL OR PLUMBING EQUIPMENT, OR WINDOWS, DORS OR OTHER ARCHITECTURAL FEATURES, SHALL BE VERIFIED WITH THE ACTUAL PURCHASED ITEM PRIOR TO PROCEEDING WITH THE STRUCTURAL WORK AFFECTED. NOTIFY THE ARCHITECT IF DIMENSIONAL REQUIREMENTS VARY FROM THOSE INDICATED ON THE DRAWINGS. 13. PRE-ENGINEERED FLOOR JOISTS: (NOT USED ON THIS PROJECT) GREATER SPAN 8113 S2/3 is. 14. A. ALI. TIMBER CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF THE'NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION' (NDS), 2018 EDITION. B. WOOD COLUMNS AND BEAMS SHALL BE SOUTHERN PINE. THE FOLLOWING DESIGN CRITERIA SHALL APPLY: 1, FOR BEAMS AND COLUMNS No. 2 GRADE, SURFACE DRY WITH 19% MAXIMUM MOISTURE CONTENT 2. FOR STUDS AND PLATES HEM FIR OR SOUTHERN PT PINE CONSTRUCTION GRADE C. AN DEVIATION SHALL BE APPROVED BYARCHITECT IN ADVANCE D. CROSS BRIDGING SHALL BE PROVIDED OR APPROVED BY ARCHITECT IN ADVANCE E. ALL STRUCTURAL LUMBER AND FASTENINGS SHALL CONFORM TO THE 'NATIONAL DESIGN SPECIFICATION FOR STRESS -GRADE CUT LUMBER AND I rs FABRICATION'. FOLLOW MINIMUM RECOMMENDED FASTENING SCHEDULE AS PER THE FBC AND OTHERWISE NOTED ON THE PLAN. F. W RKMANSHIP SHALL BE FIRST CLASS IN ALL RESPECTS AND MEET THE R QUIREMENTS OF'STANDARD GOOD PRACTICE', NORMAL TO THE A. PL WOOD SHALL COMPLY WITH THE PLYWOOD DESIGN SPECI ICATION BY THE AMERICAN PLYWOOD ASSOCIATION (APA). B. PLYWOOD SHEATHING SHALL BE EXTERIOR 5/8" CDX, APA RATED SHEATHING, EXTERIOR, 48/24 PANEL IDENTIFICATION. C. PL GOD SUB -FLOORING SHALL BE 3/4" T&G PT , APA RATED. D. PR VIDE BLOCKING AT ALL PLYWOOD PANEL JOINTS. E. PL OOD MAYBE NAILED WITH THE USE OF AN AIR POWERED GUN EXCE T WHERE NOTED OTHERWISE. THE NAIL SHALL BE DRIVEN BUT IN NO GkSE SHALL THE DRIVING OF THE NAILS BREAK OR SPLIT THE FACE PLY O = THE PLYWOOD SHEET. PLYWOOD SHEETS WITH BROKEN OR SPLIT ACES SHALL BE REMOVED AND NEW SHEETS PLACED AS DIRECTED AT THE EXPENSE OF THE CONTRACTOR. 15. PLYWO D FASTENING A. RO F- REFER TO APPLICABLE STRUCTURAL SHEETS FOR ROOF NAILI G REQUIREMENTS. B. WA�LS-REFER TO APPLICABLE STRUCTURAL SHEETS FOR WALL NAILING REQUIREMENTS. 16. DIMEW IONAL LUMBER, HEAVY TIMBER & ROUGH CARPENTRY A. SHALL COMPLY WITH THE NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION. Fb=1200psi. SOUTHERN PINE #2 17. SHOP DRAWINGS GREATER SPAN S3/3 S2/3 o S3/3 A. SHOP DRAWINGS SUBMITTED FOR STRUCTURAL REVIEW SHALL CONSIST OF TOW SETS OF PRINTS AND ONE SET OF REPRODUCIBLE DIGIT l FILES. B. D WINGS SHALL BEAR THE CONTRACTORS APPROVAL STAMP ACCE TING RESPONSIBILITY FOR DIMENSIONS, QUANTITY AND CORR INAION WITH ALL DISCIPLINES. C. NO CHANGES OR DEVIATIONS FROM THE CONTRACT DOCUMENTS AREA CEPTED UNLESS EACH IS CLEARLY IDENTIFIED AS SUCH, AND EACH IS SPECIFICALLY ACCEPTED OR REJECTED BY THE ARCHITECT. D. AL W ONE WEEKS TIME FOR SHOP DRAWINGS TO BE REVIEWED BY THE A CHITECT. Si I I S2 1 1 S3 1 1 1 CANTILEVER CONCRETE BEAM BAR PLACING DIAGRAM BARS DESIGNATED 'C'ARE TOP CONTINUOUS THRU SPAN WITH 90 DEG STANDARD HOOKA DISCONTINUED END. LAP SPLIC'C' BARS ONLY AS NECESSARY AND WITHIN CENTER THIRD OF SPAN (30 BAR DIAM TER). 'E' BARS ARE OVER RIGHT SUPORT AS MEMBER IS READ FROM LEFT TO RIGHT.'A' BARS (BOTTOM) ARE CO TINUOUS. SEE REINFORCING LAP SPLICING SCHEDULE. FOOTING SCHEDULE MARK ELEV TOP SIZE WxDxH REINFORCING CLOSED STIRRUPS REMARKS TOP BOTTOM SIZE SPACING WF-1 -5" 12x30 (3) #6 #4 TRANSVERSE @ 48"OC WF-2 -5" 12x20 (2) #5 --- --_ WF-3 -5" 16x48 (4) #6 WF-4 5" 16x60 (5) #6 GB-1 8x20 (2)#5 (2)#5 #3 STIRRUPS @ 12" OC GB-2 8x12 (2)#5 (2)#5 #3 STIRRUPS @ 12" OC- INTEGRAL WITH SLAB COLUMN SCHEDULE MARK TYPE SIZE WxD VERTICAL REINFORCING TIE SPACING REMARKS 1 CONC 8x16 (8) #6 #3 @ 12" oc 2 CONC IRREGULAR (10) #6 #3 @ 12" oc 3 CONC 8x8 (4) #6 #3 @ 12" oc 4 WOOD 6x6 - COLUMN SCHEDULE NOTES: THE SCHEDULED SIZES ARE MINIMUM STRUCTURAL SIZES FOR REINFORCING STEEL FABRICATION. NOTE ABOUT GRADES: THE SOILS REPORT INDICATES 6" OF TOP SOIL. AT THE LOW POINT OF THE SITE, EXCAVATE 8" DOWN TO CLEAN SAND. THIS IS THE PROPOSED ELEVATION OF THE BOTTOM OF THE CONTINUOUS FOOTINGS. THIS WILL ALSO SET THE TOP OF ALL FOOTINGS AT ELEV +5.10'. REFER TO THE SOILS REPORT FOR FILLING AND COMPACTING FILL AROUND THE BUILDING. MAINTAIN A MIN. OF 8" SOIL COVER OVER THE TOP OF THE FOOTINGS. t�t7 8" CMU W/ #5 @ 32" OC FOUNDATION PLAN NOTES: 1. FLOOR SLABS SHALL BE 5" CONCRETE SLAB W/ 6x6 W1.4xW1.4 WWF ON 10 MIL VAPOR BARRIER OVER CLEAN COMPACTED, TERMITE TREATED, SUB GRADE (TYP). FIBER CONCRETE CAN BE USED AS WELL. 2. TOP OF NEW FOOTING PADS SHALL BE (-5") BELOW EXIST SLAB (UNLESS OTHERWISE NOTED). 3. ALL FOOTINGS ARE CENTERED BENEATH BEARING WALLS AND COLUMNS, TYPICAL OR UNLESS OTHERWISE NOTED. 4. COORDINATE TOP OF SLAB WITH FINAL FLOOR FINISHES, SLAB RECESSES AND FLOOR SLOPES. SEE ARCHITECTURAL PLAN FOR FINISH ELEVATIONS. 5. CONCRETE FOR SLABS SHALL BE 3000psi'ULTRA' WITH FIBER. 6. 8"CMU INDICATES 8" NOMINAL CONCRETE MASONRY UNITS W/ (1) #5 BAR @ 48" OC (MAX) IN GROUT FILLED CELL, UNLESS OTHERWISE NOTED. 7. PROVIDE #9 LADDER TYPE JOINT REINFORCING @ 16" OC (EVERY SECOND COURSE) FOR CONCRETE MASONRY UNITS. 8. COORDINATE THE STRUCTURAL DRAWINGS WITH THE ARCHITECTURAL DRAWINGS FOR DOOR AND WINDOW ROUGH OPENINGS, DIMENSIONS AND LOCATIONS. 9. WHERE BEAMS ARE NOT DESIGNATED OVER 8" CMU WALL OPENINGS, PROVIDE REINFORCED CAST - IN -PLACE CONCRETE LINTELS (IF APPLICABLE). 10. NEW CONCRETE COLUMNS, PILE CAPS AND GRADE BEAMS SHALL BE 4000psi CONCRETE, SEE COLUMN & FOOTING SCHEDULE FOR STEEL DETAILS. 11. CONTRACTOR SHALL NOTIFY THE ARCHITECT FOR ANY CONDITION THAT DIFFERS FROM CONSTRUCTION DOCUMENTS DETAILS AND SPECIFICATIONS. EXISTING SLAB ON GRADE CRACKS OR WALL CRACKS THAT MAY INDICATE SETTLEMENT SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR CORRECTIVE ACTION. 12. WHERE NEW FOOTINGS MEET EXISTING FOOTINGS, DRILL & EPDXY DOWELS MATCHING THE SIZE AND AMOUNT TO NEW FOOTING REINFORCING 12" LONG W/A 6" EMBED. EXIST GRADE +4.771 TOP OF FOOTING 1+5.10' WF-2 22'-6" 5" RC SLAB (USING 4000psi FIBER) & 6x6 10/10 WWM OVER 6 MIL VISQUEEN VAPOR BARRIER (3)#6 VERTICAL (2)#6 VIER N NOTE: SHEAR WALL W/ #6 VERT BARS @ 16" OC r WF-2 3 I WF-2 C \1- N (FOR STEPS) C 52.0 DOWEL IF SEPARATE POUR N WF-3 16'4; WF-2 8"CMU W/ #6 VERTICAL @ 32"OC (TYPICAL TO TOWER) -THICKEN SLAB UNDER STAIR FOR STEP DOWN 8"CMU W/ #5 TO OUTSIDE STORAGE VERTICAL AT 32"OC _ (TYPICAL) M 13'-6° LL W F-4 2 GB-2 n �- NOTE: SHEAR WALL W/ #6 VERT BARS @ 16" OC 5" C NCRETE RC SLAB (USING 4000psi ULTRA -FIBER) - & 6 6 10/10 WWM OVER 6 MIL VIS QUEEN VAPOR BARRIER 04 N 30'-4 3/8" 1 WF-2 I. EQ.� 20,-4e 1 H I EQ. m a C9 N N 0 y WF-2 A FOUNDATION PLAN 1a0 SCALE:3/16"=1'-0" 2,-8n PRINTED March 5, 2021 V W wmarthur ARCHITECT OF RECORD William F. Arthur AR-0012074 L V . -J M (0 L_ -CL0 = M O M X _0 C O QC - LL C (n to U O N Rlt N G O_ Os - O RZI- M M L O O LL C N m >,CO y En U N N U V z0� 3 m O to 0) ra m E U a)U z C C: U C U Q C a (D a- th a a a Q c~i w O Q'O O -CC L w o a CL N O � Z O (6 0 N STRUCTURAL Soe Ga ,..04 TIE BEAM +37.75' NAVD - z ILINTEL 8x8 W/ (2)#5 STAINLESS STEEL WIRE AND POST RAIL SYSTEM - BORE POST THROUGH FINISH MATERIAL & CONC. & SET IN EPDXY 3rd LEVEL +29.75' #5 @ 12" OC LONG SPAN HOOK #4 @ 12" OC --- REFER TO PROJECT BOOKLET FOR COLLAR TIE DESIGN BM-2 —TYP. #5 @ 32" OC STUCCO STOP & COUNTER FLASH �2x RIPPED AND BOLTED TO TB-1 / W/ 5/8" ANCHOR BOLT SIMPSON STRONG T !!!!!!!!JOIST HANGER FOR G13Z UG E 0,DJUSTABLE 3xffi @ 24" OC OTB-1 (IN WALL)_. ---------------- I I I I SEE STAIR STEEL L_ AT LEFT SECTION - -- --- SM-1 (IN SLAB)- -- OBM-1 (IN SLAB) 1 - TB-1 (ABOVE) I i i OiTB-1 (UPPER) I M rI L° . i• I :II I I' r° 11�IN� r{ I_L11 _I-LLL_I_LLJ L #5 BOTTOM FOR SPAN @12"OC TI 1 1 1 1 1 " �� _ r1 r 1 1 I= - �r _�—#4 BOTTOM TRANSVERSE @ 12" OC L 1 I J_L1 ----- --- #4 TOP BAR 4'-0" @ 12" OC - I_L11J_L11-LL1J_L TI I I' I I I I 4=r-T7 I rT - I - T1 l I I I I I I _I_L11._L LL1_I_ LLJ-L_ 7-1 1 1 II I I m ,I T I I I I I I 1 7--T-7 +=r 7-1 rr_T -r=.-F -4-1-4-+-1-1-� TI I I I I I TTTTr H-f T rT7 =F r-r-1-r+-�-+- TF 1. 1 +=rr-r 1 rr-r-r- - 1-I_L1 i_I_L1.J __L TI I I I I I _T-L1 I_I_I_11_I_Lh._I_I TI (:I - =r=r r � r r r � +=FT­7=F- - --- I-F-+-1 1 + IH 1111II 1 111311 1 111•I f1 J:. O TB--1 (LOWER) fi 11{I 1. 2 O 2C A 2nd FLOOR FRAMING PLAN S2.0SCALE; 3/16"=1'-0" 4 1 ° SS WIRE HANDRAIL - #5 @ 12" OC LONG SPAN TB 1 2nd LEVEL _ #4 @ 12" OC SHORT SPAN HOOK INTO BM-1� -- -- ---------------------- - BM-2(ABOVE) O ti #6 VERTICAL @ 16" OC - - f i- 1 a °-I h-I Sii . f 1% I 1 i r :j�'� AT SHEAR WALL LOCATION - 9> w I T" Tl-"-7"1'-I"T'T d it 6" CONC SLAB Wl f - - r 11{I�r�trir�---; >j (4)#5 LONG _ i� &#4TRANSVERSE -1_LL LL11 L11c1_L1J Lam, O -- --- BPv a SILL 8x8 w/ ,� -----+�+�--�-+-a (2)#5 -POURED CON STAIRCASE TB-1 (IN WALL) m -IL I + � +1_I_L�1-J��° m a OWNER ELECTED --------------- r -t-BVV A ----- WITH - --- @ 01 FINISH -REFER O STRUCTURAL #5 BOTTOM FOR SPAN 12"OC FOR DETAILS _I_I 1 _ I_- /- -#4 BOTTOM TRANSVERSE @ 12" OC L___BM-1 QN SLABZ-- _ _ _ SEE STAIR STEEL -- ++4 I I-i� - - �#4 TOP BAR 4'-0" @ 12" OC HOOK #4@12"OC-� -_ —__-__.___-- AT LEFT SECTION _LLL Lil I L '1-r_L1__L - ., TB-1 .' --- I. 1 LL1 L11_- _ - Q TB-1 I --- - #5 @ 12"OC TOP + -I & BOTTOM OF STAIR ) L11 - #6@16"OCAT T co L I_I 1 I_Ln T m SHEAR WALL _.-_.-___ ._... - L I_ I >_ Q#4TRANSVERSE --1777 rr7-` PER GRADING LOCATION -__- q 1 _:::__ .._..--- -- ----- -----m .`r__..1J-++ + _ - F-- @12"OC ---- 8" CMU AS BM-1 --_ - __ BM-1 (IN SLAB) I-- - 1 HOUR FIRE o / — 11" -- RATED WALL I r I I 1 BELOWSTAIR�\ _,I, O BM-1(IN SLAB) �rrr�-I rr� y a CHECK LENGTH OF John Deere --I- r TT T I-�-tr-t-�r i r-�+-i�tT-± FOR THIS DIMENSION i_i_ 1 I i_L +i_ 1 -- lst LEVEL R p -1-4-- I-11-L-L1-1 *STORAGE LEVEL GB-1 n e e d a e o a a o a a P ^ d O '-T �T-f Try O +7.58' aGB-2t N GB 2 GB 2 GB 2• GB 2 w" j r Q9� S TTI"I,dr, fMr I I 3 TOP 0 (ABOVE) BM 2 SPAN GRADE BEAMS BETWEEN - STAIRWELL WALLS & OVER _ N S All OO COMPACTED SAND FILL +5.10 G NOTE. v FOOTING DEPTHS VARY WF-2 -2 WF-4 \2,0 WF-3 SAND FILL KC STRUCTURAL WA L SECTION REPORTTLOCATEEDPACTED INPROJECTBOOKAS PER OLILS ET B 3rd FLOOR FRAMING PLAN 52,Q SCALE: 3/8"=1'-0" SCALE; 3/16"=1'-0" a r 0 z z w 0 O U U z 0 J M m w w a W w m is JAII wmarthur ARCHITECT OF RECORD William F. Arthur AR-0012074 i 7 m U � S L_ Lr) = M i N M t 0 -� i Q O U_ E (0 w � = � U O � N C CL 0` d 01 M O 0 TT U � C > � > m N CO U N O N U ro U N z O CO U) ro CD a U (1)U z C U C U C W 13 Q 06 l6 Q ++ c Q c~i W 0 O qt t w O O 0 CDO rp a CL N z O 0 N STRUCTURAL PRINTED March 3, 2022 3rd LEVEL I�� in m.�. +29.25' — -- T -- -------------------------- a,e i d R d d d d .. TYP. #5 @ 32" OC SILL 8x8 w/ '_-____ _ _ ...-._ __ � _,:_ -I - (2)#5 - - - BM-1 #6 VERTICAL @ 16" OC d ° _ STUCCO STOP & COUNTER FLASH HI #5 @ 12" OC LONG SPAN 2x RIPPED AND BOLTED TO TB-1 / W/ 5/8" ANCHOR BOLTS 32" OC - SIMPSON STRONG TIE kDJUSTABLE HOOK #4 @ 12" OC d TB-1 JOIST HANGER FOR 3x@ @ 24" OC « 6" CONC SLAB W/ (4)#5 LONG FNTO E TB-1 I d s & #4 TRANSVERSE f . . @12" OC F o BM 1 e n d y i o d n 1 I o ' d 1 i ° I SS WIRE HANDRAIL #5 @ 12" OC LONG SPAN TB-1 I I f • 2nd LEVEL --- #4 @ 12" OC SHORT SPAN +18.75' e 9 HOOK INTO BM-1 0 ------- ----------------------- —_ #6VERTICAL @16"OC _- 6" CONC SLAB W/ AT SHEAR WALL LOCATION - (4)#5 LONG -_ & #4 TRANSVERSE _ @12„ OC BM-1 _- BI 1 d SILL 8x8 w/ 1 d .' - (2)#5 ---POURED CONC STAIRCASE r- - _ WITH OWNER SELECTED - FINISH -REFER TO STRUCTURAL FOR DETAILS y HOOK #4 @ 12" OC - d TB-1 o TB-1 #5 @ 12"OC TOP d & BOTTOM OF STAIR #6@16"OCAT SHEAR WALL LOCATION - - #4TRANSVERSE _ @12"OC - 8" CMU AS BM 1 - 1 HOUR FIRE \ RATED WALL 11" BELOW STAIR L \ I CHECK LENGTH OF Jahn Deere _ FOR THIS DIMENSION i 1st LEVEL +8.25. - 11 d d a STORAGE LEVEL --- - --------------- e. , .d d e ` m a a � m- - . GB-1 ' _..._..-..—.�a—... a a - G62 GB-2 , GB-2 GB 2 . SPAN GRADE BEAMS BETWEEN _ STAIRWELL WALLS & OVER - _ - - COMPACTED SAND FILL - WF-2 F-2 WF4 WF-3 e C�STRUCTU RAL WALL LS SECTION SAND FILLLOCATED IN PROJETED CT BOOKER LET REPORT LOCATED IN PROJECT BOOKLET SZ,Q SCALE:3/8"=1'-0" 0 0 O TB-1 (IN WALL) --------------- I I I I SEE STAIR STEEL L--I-BM-1 LIN SLABJ__ AT LEFT SECTION — - OBM-1 (IN SLAB) 1 I * TB-1 (ABOVE) I FO TB-1 UPPER . .I _I_L1 _I_L11 _I_L11_I_L1 J_L I I I I I I I �- -- _ L1_I_L11 I_J_Ll I I I 16 I I ----rr-r-l-rti-- - ---I-+d-1-I-+-4== - _I_L1_I_L11_I_LJ11.-1-LIJ_L I_ I I_I I I I____ I I I I I I I ----rt-t-rrr-r-- - --. +4-1-F-+A-- L- J_ L 1_I_ L.11_I-L 11_I_L 1 J_L II I I ----rrr-rrt7-- - --1-+4-1-F-+-4-- _L1-I_L11 _I-L 1-1_I_L 1 J-L II I.I I II - m- -_---I I. 1 1 1-_-I- I -- - I I I I 1 I I I 1 I 1 I I I I I I_I_LI _I_L I I I I. I. _ - 4-1- 4 -1L-14-1-1-.I--1-L. I I_I_I_11 _I_I_1.1 _I-L1_I_L 1 , ----rT7—I rr7-- - -1_1 1_1_L I I_I-L 11_1-11_1_1__. I I. I I I I 1_1_L1 1_1._1 1JJ-L1J_L 11 1 I I __ F=T_!_F_T7_[_F_T7_1_F:F:9-F -l-4-�14-I I-14_1-1-1J I- L 1_L11J LI I_I_1 1 1 1 _ 11{I _ ' �-- _ - - - . Z_I_ '._-1_1 "-` I r#5 BOTTOM FOR SPAN @ 12"OC #4 BOTTOM TRANSVERSE @ 12" OC #4 TOP BAR 4'-0" @ 12" OC U U 2nd FLOOR FRAMING PLAN SZ.QJSCALE; 3/16"=1'-0" f,q OBM-2 (ABOVE) 1 3 d � m TB-1 (IN WALL) __,____-__---__ m I I I SEE STAIR STEEL __1-BM-ILIN SLAB]__ AT LEFT SECTION ----- m i IBM-1 (IN SLAB) I I I BM-1 -SLAB) TB-1 (ABOVE) O O n i 3 TOP OF O BM-2 (ABOVE) FOOTINGS 3O 3O +5.10' NOTE: FOOTING DEPTHS VARY C 5C B 2nd FLOOR FRAMING PLAN S2.Q SCALE; 3/16"=1'-0" 7 I. I' li I �I 1 1- 'I -- -I_L1_I_L11 _I_FYL++11-1_L1 1 1 1 .�J L Y- --- r 7-I F 1 Il� -1 r r i-T-,--�-r-�, J_L1. I L11 _I L11 _I_L1J L�� I LLl .Lr1 L rr g A 4_- I_ L11_1_ L11_1_L1 _ -- --r-r-r-I- r-- - -- - F-+4-1-I-+ 7-T-T-T-11 1111 L I'.. ----rr-t-rrr-r-- - I_L1 I L11_I L111_L1J L I.I-I 1 1 1 - -rr-r-I rr-r-- --+4-1 4+4-1-4+-I "f I I I I I I I I I II I I I _l_L I_I I IJ 1 L11 J-L1 1 1 1 1 1 rr r-I rr�-- I T 1 1 1 1 1 I f 'f-iTfF ram-+-r r r -I r r� - -1=rr � -I-L1 LI I I_I 11-1-L1J L rr-r- r-T7 ,, ✓- 11 -.L1 1 - rr-r-I 1 rr� � -- --1 -r r�9j1Nr Sh rr� r �- - , i a r_r - ) 1�1 �pl r - - #5 BOTTOM FOR SPAN @ 12"OC #4 BOTTOM TRANSVERSE @ 12" OC #4 TOP BAR 4'-0" @ 12" OC PRINTED March 5, 2021 Y a. ML A` wmarthur ARCHITECTOF RECORD William F. Arthur AR-0012074 L m nUn`` L_ s L0 O7 _ 2 tM O M t t _0 v N C) U �j N V V M M O •O 0 LL U_ U j -0 - U a 0 In U U a ro 0 z� C U O •U-- z +C,, , U : ••-F, Q C -C U W 0 °z 2 c~i O 0M O f6M p CLN ZO0N Z STRUCTURAL S-2.Q Values Building Values Symbol value a 3.0 End Zone 6A Kh Li Kt L0 46.6 sit s39 700.0 a 11.5 V uMmste Y nominall 128 I 1A Root Angle L2 Gcpi02 (Wall - Items 4 09 GCp-(Wail-Z=e4) -09 GCp+(Wall - zone 5) 0.7 (14- all -Zones -L0 C Rools -09 Reduction Factor 09 bAdurtmentFactor L6 Exposure D Topographic Factor Values Symbol value Hill shape Nat-NOHKI Kl 0.0 K2 0.0 K3 OA Kit Lo p OA gamma OA H QA Lh OA a U s 010 Topouraphe: Fact Eqn. 63 (ASCE 7) Krt=(1+K1-K2'K3)^2 Note: .The symbols that are not shown are Included in the calculations, but due to the fact that they are not the same for each case (for muhiple eHective wind areas) they are not listed above, ENCLOSED BUILDING - WALLS1 h<_60FT(h518.3m) ELEVATION COLUMN SCHEDULE MARK TYPE SIZE WxD VERTICAL REINFORCING TIE SPACING REMARKS 1 CONC 8x16 (8) #6 #3 ® 12" oc SEE COL. TYPE DTL #4 H/S3.0 2 CONC IRREGULAR (4) #6 #3 @ 12" oc SEE COL. DTL #4 H/S3.0 3 CONC 8x8 (4) #6 #3 @ 12" oc SEE COL. TYPE DTL #4 H/S3.0 4 WOOD 6x6 SEE COL. TYPE DTL #4 H/S3.0 COLUMN SCHEDULE NOTES: THE SCHEDULED SIZES ARE MINIMUM STRUCTURAL SIZES FOR REINFORCING STEEL FABRICA ION. Notation a = 1Oral of least horizontal dimension or 0.4h, whichever is smaller, but not less than either 4%, of least horizontal dimension or 3 ft (0.9 m). Exception: for buildings with 8 =00 to 70 and a least horizontal dimension greater than 300 ft (90 m), dimension a shall be limited to a maximum of 0.8h. h = Mean roof height, in ft (m), except that eave height shall be used for 6 5 100. 8 = Angle of plane of roof from horizontal, in degrees. HIP ROOFS 20 < O 5 27 DEGREES (roof -�&-overhang) I I a i t7 i ta Notation a = 10%of least horizontal din dimension or 3 ft (0.9 m).'. overhang. The horizontal c R = Horizontal dimension of bI h = Mean roof height, in ft (m) 8 = Angle of plane of roof fror ZONE (+19.84#,-40.5#) f B ELEVATION G WIND PRESSURE DIAGRAM S2.0%SCALE: NTS BLEND 3x8 RIDGE & 3x6 RAFTER W/ EPDXY SCARF JOINT AIL ZONE 3 (+36.44#,-90.14#) LET-IN 2x4 RIPPED SUB -FASCIA TO RECEIVE 2x6 PT FASCAI BOARD REFER TO PROJECT BOOKLET STRUCTURAL CALCULATIONS FOR INTERPOLATION OF WIND LOADS FOR COMPONENTS (+24.82#,-67.89#) m H- 2. HANDSHAKE RIDGE EPDXY & BOLTED C M-10--rak _ W/ R-19 BA THIS L FRAMING UPPER LEVEL : 3/16"=1'-Orr RAFTER HANDPHAKE DT'L AT RIDGE/RAFTER SCALE: NT ONL' BLEND 3x8 RIDGE & 3x6 RAFTER W/ EPDXY SCARF JOINT (HANDSHAKE) -SEE DETAIL BELOW BLEND 3x8 RIDGE & 3x6 RAFTER W/ EPDXY SCARF JOINT (HANDSHAKE) -SEE DETAIL BELOW ROOF PLAN NOTES 1) THE ROOF STRUCTURE IS 5/8" PLYWD SHEATHING OVER 2x6 PINE BEAMS. PLYWD IS NAILED WITH 10d RING ROOF PLAN NOTES 1) THE ROOF STRUCTURE AT 3RD LEVEL IS 3/4" T&G PINE SHEATHING OVER 3x6 DOUGLAS FIR (SOUTH) BEAMS. T&G IS NAILED WITH (3) 10d RING SHANK NAILS 0 EA BOARD. 2) THRU BOLTS ARE 5/8" STAINLESS STEEL TREADED ROD WITH STAINLESS WASHERS AND NUTS INTO 3x6 BEAMS. 3) THE RIDGE IS INTEGRAL WITH THE END RAFTERS BY CREATING A'HANDSHAKE' JOINTAND LAMINATING THE CONNECTION WITH'WEST SYSTEM' EPDXY#105 MIXED WITH #207 SPECIAL HARDENER AND #406 SILICA. MIX TO A TEANUT BUTTER' CONSISTENCY AND CLAMP OVER NIGHT. SEE DETAIL SHEET F/S-2.0 THIS SHEET. BEAM SCHEDULE MARK TYPE Wxp REINFORCING STIRRUPS REMARKS TB-1 CONC 8x12 (4) #5 #3 @ 12" OC SEE PROJECT BOOKLET FOR STRUCTURAL CALCULATIONS BM-1 CONC 8x12 (4) #5 #3 @ 12" OC RB-1 CONC 8A2 (4)#5 #3®12"OC SEE DETAIL SHEETS-4.0 WB-1 I WOOD 410 1 - I - ROOF FRAMING GROUND LEVEL SCALE: 3/16"=V-0" SIMPSON `STRONG -TIE' CONNECTION SCHEDULE CONNECTION DESCRIPTION SIMPSON SPEC UPLIFT ALLOW UPLIFT ACTUAL GRAVITY ALLOW GRAVITY ACTUAL F1 ALLOW/ F1 ACTUAL F2 ALLOW/ F2 ACTUAL CODE COMPLIANCE REMARKS RAFTER TO RIDGE LRU26Z 770 238 990 <238 4851142 FL10447 RAFTER TO PLATE NA 980 570 4x4xlA ST'L ANGLE RAFTER TO HIP LSSJ26 295 <238 FL10865 HIP TO PLATE NA 590 <238 441/4 ST'L ANGLE TRUSS TO PLATE HHETAI2 2120 1800 340 770 FL11473 PRINTED March 5, 2021 wmarthur F At? 4��p,M 0� AR0012074- o� RED=ARON\ ARCHITECT OF RECORD William F. Arthur AR-0012074 i m U -C 1O � Q 2 M L N M X o tt -C O QLL C t E o y M , U _> � m c CL ON O` M M r0 (0 L L p O L O LL LL. U j O C L to -C to U N U w z� N O U (D 0 O [Q v) t0 m C N U z C Q 4U C ul CO .V. :3 0 0 -C N a 1= LU t a -C 'C 0 0 0 o 1 (0 0 aa_N Z0QN Z STRUCTURAL S-3� Or 0 2x6 PT P 1/2"x8" A @ 32" 0( PAINTED 1x6 T&G PINE DECKING 2x4 GROUND @ 16.00 NSULATION 5/8" CDX PLYWOOD LET -IN PT 2x4 SUB -FASCIA i — PT 2x6 PAINTED FASCIA FA\/F AT SxR nPFN RAFTER EAVE AT 2x6 TOP CORD TRUSS OUTLOOKERS NOT SHOWN FOR CLARITY ,HANKS @ 4" OC [AILS TO PENETRATE 1ND SUB -FASCIA FASCIA AND SUB -FASCIA BOARDS TO BE LAP -CONNECTED SCARF JOINTS USING WEST SYSTEM EPDXY OR EQUAL. CORNERS TO BE MITERED WITH EPDXY. " CDX PLY TO LINE UP WITH i T&G DECKING AT EAVE-NAIL 2X6 TRUSS TOP CORD W/ 1 Od JG SHANKS AT 6" OC 'PLY METAL ROOF OVER 5/8" )X PLYWOOD 4 GROUNDS @ 16" OC PTIONAL INSULATION BOARD RIPPED 2x FILLER BETWEEN TRUSSES WITH (2) 2" ROUND VENT HOLES BETWEEN TRUSSES A GABLE END AT FRONT PORCH S4.0 SCALE: NTS #6 VERTICALS BARS @ 32.00 IN BLOCK BETWEEN RAKE BEAM & TIE BEAM CONC RAKED BEAM REINF. W/ (2) #5 TOP & BOTT. ENCLOSED W/#3 STIRRUPS @ 12.00 TIE BEAM W/ (2) #5 BARS TOP & BOTTOM & #3 STIRRUPS @ 12" OC WELDED WIRE FABRIC PREFAB 22 go. GALV. STEEL FORM TO BE INSTALLED AS PER MANUFACTURER'S SPECS. —x—x—x=x I x—x—x—x CONSTRUCTION JOINT DETAIL 1/8" WIDE, 1/4 SLAB OUT ALTERNATE WIRE DEPTH SAW CUT WITH / -AT CONTROL JOINT, IN 18 hrs x— x— x— x I- x— x— x— x— L,FILL SAWCUT WITH NON -SHRINK GROUT. CONTRACTION JOINT DETAIL N9IEL PROVIDE CONSTRUCTION / CONTRACTION JOINTS AT INTERVALS NOT TO EXCEED 12'-0"o.c. IN EACH DIRECTION E CONTRACTION JOINT DETAILS S4.0SCALE: NTS 1" x _" CORRUGATED WALL TIE 0 16"o.c. MAXIMUM SPACING w/ (E) 3/16" x TAPCONS AT EACH TIE INTO EXISTING ROUGH OPENING. -\ EXISTING JAMB EXISTING HEAD [I II L � _ (1) y6 DOWELS SET w/ 2 PART —EPDXY, 6" EMBED. TYPICAL TOP & BOTTOM. p9 LADDER TYPE JOINT REINFORCING 0 16% _ NEW CMU INFILL w/ (1) /6 46"ox. IN GROUT FILLED CELL MIN (2) PER LOCATION (1) 6 DOWELS SET w/ 2 PART —EPDXY, 6" EMBED. TYPICAL TOP & BOTTOM. EXISTING SILLNOlE, 1. USED WITHOUT MODIFICATION OF EXISTING ROUGH OPENING. TYPICAL C.M.U. OPENING CLOSURE DETAIL F 1TYP. CMU OPENING CLOSURE DTL S4.0 j SCALE: NTS #4 @12" TEMP #5 @ 12" TOP 8" X 8" CONC. BEAM SILL W/ (2) {5 BAR CONT. 8" CMU WALL 69 LADDER TYPE JOINT REINFORCING ® 16' ox. VERTICAL SPACING. ELEV: SEE PLAN NOTE: THIS DETAIL TO BE USED FOR ALL WINDOWS SILLS LESS THAN 4'-0" WIDE. 1/2" EXP. JOINT NEW 4"CONC. SLAB ON 10 MIL POLYETHYLENE VAPOR BARRIER W/ 6 X 6 - W 1.4 X W 1.4 WELDED WIRE FABRIC REINFORCING. h ELEV: 0'-0" -'—'—'—'—'— FINS FLR. SLAB -COMPACT CLEAN ALL. h. ELEV.: - 1'-4" � T0. FTG. (U.N.O.) w n j3" CUR. TYP. CONTINUOUS FOOTING SEE FTG, SCH. TYP. (SEE PLAN FOR SIZE). D*N\8"CMU @ WINDOW DETAIL S4.0 / SCALE: NTS NEW 4"CDNC, SLAB ON 10 MIL - POLYETHYLENE VAPOR BARRIER W/ 6 X 6 - W 1.4 X W 1.4 WELDED WIRE FABRIC REINFORCING. CONCRETE COLUMN (SEE PLAN SCHEDULE) 1/2" EXP. JOINT. - U-U EXT. FIN. GRADE. m COMPACT CLEAN FILL TERMITE TREATED. A E16- - 1'-4 e6 TO. FTGFTG. (U.N.0) CONTINUOUS FOOTING— • , i I , , (SEE PLAN FOR SIZE). --- --� SEE FTG SCHEDULE C CONCRETE COLUMN DETAIL S4.0 SCALE: NTS whys:. TYP. 3/4" SI OR CONC RECESSS' RECEIVE r- #5 @ 12" BOTTOM MASONRY I G STEPS AT PORCHES S4.0 SCALE: NTS NEW WF-2 SEE FOOTING SCHEDULE v M B TYP. CMU RECESS DETAIL S4,0 SCALE: NTS REINFORCED FILLED CELL SEE PLAN FOR SIZE AND SPACING 9 GAUGE HORIZONTAL REINFORCEMENT EVERY OTHER COURSE (LADDER TYPE) f/ 9 GUAGE HORIZONTAL 8"x8"x16" CONCRETE REINFORCEMENT MASONRY UNITS EVERY OTHER COURSE (LADDER TYPE) TYPICAL MASONRY CONSTRUCTION DETAIL PRINTED March 5, 2021 wmarthur W ..P tPM F.A@Ty �. c�+ AR00120T4 p�, ED AR ARCHITECT OF RECORD William F. Arthur AR-0012074 L m a To s U � 2) Q = � M L 0) M X' -a -C t �- a � O E N N (6 U — O N S 0- ON D` Itt O� d M Mm ,V O O O LL -O LL -O j U -O N DO -C y N :k -z V) U N U (I) O U N O n3 00 m rn C rn w O ��-F- C �� Z +C Q C C .0 J., c~i O Q L C Q C w � 0O S 'C 'o OQO 0 a CL N Z 0 N Z STRUCTURAL MR1TE5 Ql<I - PERFORATED VW LAP tr 7111 W ABOVE TOP OF CO PAN - AIR KMaER UW - PREFAB. WTAL FRAW # - AUx1LGARY ORAB1 PAN l 5' - Ir.a, PtU5 NOTES: A. SLOPE MAIN LINE TO CONDENSATE RECEPTOR M Vr PER FOOT) B. DRAIN LK SHALL BE PVC AND INSULATED C. TSP a FAN TOTAL STATIC PRESSURE AC CONDENSATE P-TRAP DTL SCALE: NITS -man 0- 1 1 %- x U 6A I - sow SIM BY STRAP p 8--01uC P - 1" MMbMINi LE1r5Ti1 i4Y-r wall: x22SA wo " STM AT SUPPORT. - pxT tow - r S, - CeUAP - 5- "ww iMTN APOitUM ACT- S' lUAX SPAC#>Mi ON STRpw - M KR s M1 fl2t $104 i1A 212 PRMAP iN TAPS 00100IIIIIIIIIIS STRAP a - Ol~P05m via am" 6 $ww FOR DUCT HANGER AND DISCHARGE BOX DTL SCALE: NTS AIR DISTRIBUTION SCHEDULE SYMBOL USE TYPE ACCESSORIES DESIGN, MFR & MODEL # A SUPPLY AIR CEILING DIFFUSER O.B.D. TITUS 250-AA B SUPPLY/ RETURN AIR SIDEWALL LINEAR BALANCE DAMPER TITUS CT-480, 3" WIDE C SUPPLY/ RETURN AIR CEILING GRILLE ADJ. PATTERN CONTROL & BAL. DAMPER TITUS FLOBAR FL-20, 1 2" SLOT D RETURN AIR CEILING GRILLE ADJ. PATTERN CONTROL & BAL. DAMPER TITUS FLOBAR FL-10, 2 1" SLOTS E SUPPLY/ RETURN AIR SIDEWALL/CL'G REGISTER ADJ. PATTERN CONTROL & BAL. DAMPER TITUS FLOBAR FL-10, 1 1" SLOT MECHANICAL NOTES 1. ALL WORK ISHALL BE PERFORMED IN ACCORDANCE WITH FLORIDA BUILDING CODE,FLORIDA ENERGY EFFICIENCY CODE AND ALIL LOCAL ORDINANCES. 2. CONTRACT RS SHALL FURNISH ALL LABOR, MATERIAL, EQUIPMENT, PERMITS, FEES, INSPECTIONS AND INSURANCE S REQUIRED. 3, CONTRACIPR SHALL VERIFY SPACE CONDITIONS AND DIMENSIONS AND SHALL COORDINATE WORK WITH ALL OTHER TRAD S PRIOR TO FABRICATING DUCTWORK OR INSTALLING EQUIPMENT OR PIPING. 4. AIR CONDITIONING DUCTWORK SHALL BE CONSTRUCTED OF TWO INCH THICK (R-8 MINIMUM) FIBERGLASS DUCT BOARDI�WITH ANTI MICROBIAL COATING AND WITH REINFORCED ALUMINUM FOIL FACED COVERING I} FABRICATED ND INSTALLED PER S.M.A.C.N.A. RECOMMENDATIONS. USE R-4.2 INSULATION IN CONDITIONED SPACE. 5. ALL VENTIOTION AND EXHAUST DUCTWORK SHALL BE OF GALVANIZED SHEET METAL CONSTRUCTED AS PER S.M.A.C.N.A. RECOMMENDATIONS, 6. ALL EQUIPMENT, MATERIALS AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THTE DATE 0 ACCEPTANCE. 7. AIR CONDIfnONING SYSTEM SHALL BE BALANCED TO OBTAIN COMFORT CONDITIONS WITHOUT DRAFT IN ALL AREA AND Tq DELIVER AIR QUANTITIES INDICATED IN THE DRAWINGS. CONTRACTOR SHALL ADJUST THE COLLAR SIZES FORT IS PURPOSE AT THE BRANCH DUCT TAKE -OFF OR PROVIDE DAMPERS AT THE BRANCH DUCT TAKE- OFF. 8. THERMOS T SHALL BE PROGRAMMABLE HEAT/ COOL TYPE WITH FAN AND SYSTEMSELECTOR SWITCH 0 SUB- BASE. MOUNI ING HEIGHT PER HANDICAP CODE REQUIREMENTS. 9. ALL DUCT ELBOWS GREATER THAN FORTY-FIVE (45) DEGREES SHALL BE FITTED WITH TURNING VANES, 10. ALL DUCT DIMENSIONS INDICATED IN THE DRAWINGS ARE CLEAR AIR -SIDE DIMENSIONS. 11. PROVIDE j EADDY ACCESSIBILITY TO DAMPERS AND OTHER PARTS OF THE SYSTEM REQUIRED TO BE REACHED FOR MAINTENANCE OR OPERATIONS. 12. VERIFY A4L VOLTAGES WITH ELECTRICAL CONTRACTORS BEFORE ORDERING ANY EQUIPMENT 13. VIBRATION ISOLATION: ALL EQUIPMENT AS PER MANUFACTURE'S RECOMMENDATIONS OR AS SCHEDULED ON DRAWINGS. 14. ALL OUTSIDE EQUIPMENT SHALL BE SECURED TO WITHSTAND 175 MPH WINDS. 15. ALL EQUI MENT SHALL BE AS SPECIFIED OR APPROVED EQUAL. SUBMIT SHOP DRAWINGS INCLUDING 1/4" SCALE DUCTWORK SHOP DRAWINGS. 16. FLEXIBLE !DUCT SHALL BE FACTORY FABRICATED ROUND DUCTWORK COMPOSED OF CORROSION -RESISTANT REINFORCINC WIR HELIX PERMANENTLY BONDED AND ENCLOSED IN POLYESTER FILM, THEN COVERED WITH 1 1/2" THICK 3/4 PC (R-6 MINIMUM) DENSITY FIBERGLASS INSULATION BLANKET SHEATHED IN A VAPOR BARRIER OF ALUMINUM METALIZED POLYESTER FILM LAMINATED TO GLASS MESH, ELASTOMER BACK COATED. THE DUCT SHALL COMPLY WITH NFPA BULLETIN 90-A AND BE LISTED AS CLASS 1 AIR DUCT, UL 181. DUCT SHALL BE 'WIREMOLD'IYPE WG OR EQUAL. USE R-4.2 IN CONDITIONED SPACE. 17. EXISTING DUCTWORK NOT INDICATED TO BE REUSED SHALL BE REMOVED AND DISPOSED OF PER ARCHITECT/ OWNER INSTRUCTIONS. isi�21 '_ L9i 21 THE WORK IN OLVES INSTALLING ANEW 48KBTU SPLIT SYSTEM, A 24KBTU SPLIT & AN 18KBTU SPLIT SYSTEM ALL EQUIPMENT IS ABOVE FLOOD PLAIN FOR THE AREA. ALL DUCTWORK SHALL BE ANTI -MICR BIAL R-6. THERE ARE ALSO EXHAUST FANS LOCATED IN THE BATHROOMS & ONE FOR THE COO OP. REFER TO PROJECT BOOKLET FOR LOAD CALCULATIONS AND ENERGY COMF LIANCE. HVAC DESIG REQUIREMENTS YES NO SMOKE DUCT DETE TOR ✓ FIRE DAMPERS ✓ SMOKE DAMPERS ✓ FIRE RATED ENCLOSURE ✓ FIRE RATED ROOF/ L00 CLG ASSEMBLY ✓ FIRE STOPPING ✓ SMOKE CONTROL ✓ EXHAUST FAN SCHEDULE SYMBOL TYPE MODEL # MFG CFM SONES WATTS STAPTRIC COMMENTS EF-1 CEILING XHAUST SP-A110 D GREENHECK 110 .08 16.8 .1 BAL. FOR NEG. ROOM PRESSURE q 1st MECHANICAL PLAN M 1 SCALE: 3/16"=1'-0" PRINTED March 5, 2021 wmarthur �\'�PM F. AR y�NvN 41 b .AR0012074 0'�* FEED ARC'N\ ARCHITECT OF RECORD William F. Arthur AR-0012074 i N m U (11) >� r6 s i un = M � N M S 0 •i i -C 0 Q LL E U) N - CD W � C N 0% RCI- 0� V11 01 O% M M L: i 0 0 L 0 LL LL -0-0 >-0 m R �+m M i N t N U N U N zw a 0 V a 0 ° �:m c @m C c •UL C — a— ° Z C., Q C -C .V W 7 aU 7 U O Q-C C Q Q-0 t w 2 o -C t ow 2 O ro M a0-N Z 0 0 N 0 Z MECHANICAL K Goe0 �s I AC CONTRACTOR TO COORDINATE 1/4" LIQ & 3/8" SUC LINES W/ BUILDER FOR A CLEAN, ORGANIZED INSTALLATION ORGANIZED INSTALLATION g 3rd MECHANICAL PLAN M2 SCALE:3/16"=1'-0" NOTE: AC UNIT FOR 3rd LEVEL OBSERVATION DECK IS INTENDED FOR `COMFORT ONLY. NOTE #10 AC CONTRACTOR TO q 2nd MECHANICAL PLAN M 2 SCALE: 3/16"=1'-0" PRINTED March 3, 2022 N a 4 0 N H Z W 0 U U U' Z O J_ m Ji W a w w w a wmarthur ��.�� � M o Q' F.�qR �0 AR0012074 G ��OOSTFo ���oo RAN ARCHITECT OF RECORD William F. Arthur AR-0012074 i \m 4-+ U S i Q F = M O M X 0 t O < LL E t� W `— O U — N � C 0` ,It U d G` M M L L O O O _ LL U� a LL c > U '" U N ro z a)O U a)o O ?� M c (a m CL O+UU V) -s �1f+-s U Z c U c W (a o a) i✓ N :3 W QO tf W O o tf O � ra M a CL N Z 0 0 N O Z MECHANICAL t GorLtsd Gw,t.0 'RHEEM' RIWH12 AC CONTRACTOR TO COORDINATE 1/4" LIQ & 3/8" SUC LINES W/ BUILDER FOR A CLEAN, ORGANIZED INSTALLATION AC CONTRACTOR TO COORDINATE 1/4" LIQ & 3/8" SUC LINES W/ BUILDER FOR A CLEAN, ORGANIZED INSTALLATION 282-441 cfm 282-441 cfm -RHEENI' RIVA-I`.2 g 3rd MECHANICAL PLAN M2 SCALE:3/16"=1'-0" AC CONTRACTOR TO rnnGnIAIATG 4W I In q 2nd MECHANICAL PLAN M 2 SCALE: 3/16"=1'-0" PRINTED March 5, 2021 �i h Y, wmarthur `oFA o rN w Sa AR0012074 Q u pp�TFRPooe�oo� �pOE�p� AR ARCHITECT OF RECORD William F. Arthur AR-0012074 i m U s s LLn g' Q 2 M � O M X 0 a � �- E 0 N (B U — 0 N �N C 0_ 01 D O� O� d' d' M M L L 0 0 L . LL _O LL m M m ro t (n z� U)U J) U m o U N o O °° c mM c C U a) .+' s C-+p s Z C Q C W .U� iU+ _�uu :3 W U) = w Q d' +-C.i W d' y 0 00 O 0 O - InaCLy N Z007N Z MECHANICAL M-2.0 ELECTRICAL NOTES: 1. CONTRACTOR SHALL COORDINATE ALL HIS WORK WITH OTHER TRADES IN ORDER TO FURNISH AND INSTALL ALL WIRING AND RACEWAYS. 2. PROVIDE ALL FINAL CONNECTIONS TO ALL EQUIPMENT AND APPLIANCES. 3. BALCONY RECEPTACLES TO BE GFI AND WEATHER PROOF. 4. COORDINATE LOCATION OF ALL DISCONNECT SWITCHES WITH OTHER TRADES TO ALLOW N.E.C. REQUIREMENT CLEARANCE. 5. CIRCUITS WIRING REQUIRED TO BE AS FOLLOWS: 120V-2WIRE (L-N); 120/24OV-3 WIRE (LL-N); 240V-2WIRE (LL). WHEN EQUIPMENT GROUND IS REQUIRED INCREASE CONDUIT SIZE AS REQUIRED. 6. ALL WIRING TO BE COPPER; THHN/THWN TYPE RUN IN CONDUIT (METALLIC TYPE EMT). ROMEX IS ACCEPTABLE WHERE PERMITTED BY CODE. 7. ALL DUPLEX RECEPTACLES IN EXTERIOR AREAS TO BE OF GFI TYPE AND WEATHER PROOF. 8. MINIMUM WIRE SIZE SHALL BE #12 THHN/THWN WITHT THE EXCEPTION OF 15A GENERAL LTG. AND RECEPTACLE BRANCH CIRCUITS WHICH ARE #14 THHN/THWN, UNLESS OTHERWISE NOTED. 9. CONDUCTORS #6 AWG AND LARGER SHALL BE THW. 10. ALL CONDUCTORS SHALL BE COPPER. 11. CONDUIT IN FINISHED AREAS SHALL BE CONCEALED. 12. CONDUIT IN UNFINISHED AREAS SHALL BE EXPOSED. 13. FUSES SHALL BE DUAL ELEMENT, TIME DELAY TYPE. 14. INSTALL NYLON PULL STRING IN ALL EMPTY CONDUITS FOR FUTURE USE. 15. ALL MATERIALS SHALL BE U.L. APPROVED. 16. WORKMANSHIP SHALL BE TO BEST COMMERCIAL PRACTICE. 17. INSTALLATION SHALL BE IN ACCORDANCE WITH LOCAL, STATE AND NATIONAL CODES. 18. ALL LUMINARES SHALL BE PROPERLY SUPPORTED IN ACCORDANCE WITH THE CEILING SYSTEM MANUFACTURER'S RECOMMENDATIONS AND LOCAL CODE REQUIREMENTS. 19. ALL DEVICES SHALL BE PER BUILDING STANDARD AND SHALL MATCH EXISTING. 20. THIS DRAWING IS A GUIDE FOR THE INSTALLATION OF ELECTRICAL SERVICE. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE A FUNCTIONING SYSTEM. 21. COORDINATE CONDUIT REQUIREMENTS WITH SPEAKER, TELEPHONE, LOW VOLTAGE AND CABLE CONTRACTORS. 22. ALL BRANCH CIRCUITS SERVING DINING ROOM, LIVING ROOM, BEDROOMS, OFFICE, CLOSETS AND HALLWAYS (EXCEPT BATHROOMS) SHALL BE PROTECTED BY LISTED AFCI TYPE BREAKERS PER NEC 2014, SEC, 210,12. 23. PROVIDE LISTED TAMPER RESISTANT RECEPTACLES IN KITCHEN, DINING ROOM, LIVING ROOM, OFFICE AND BEDROOMS. CAL LE O _ WALL SCONCE RECESSED LIGHT FIXTURE Fffl VAPOR PROOF LIGHT FIXTURE vp J O JUNCTION BOX EXIT LIGHT SD COMBINATION SMOKE DETECTOR CABON MONOXIDE ALARM w/ BATTERY BACKUP PER EF R315.1.2, FBC EXHAUST FAN LS LIGHT STROBE PULL STATION BOOSTER FAN RECESSED SPEAKER BUILDING SPEAKER { DUPLEX OUTLET-15A,125V,3 WIRE lU MOUNTED @ 18" AFF, SMALL APPLIANCE, BATH DUPLEX SHALL BE 20A, 125V, 3 WIRE,GROUND TYPE WALL MOUNTED, ABOVE COUNTER UNLESS OTHERWISE NOTED, 4 EXISTING DUPLEX OUTLET -DO NOT DISTURB 4 OUTLET REMOVED AT DEMOLITION SPECIAL PURPOSE OUTLET 240V TELEPHONE JACK 41 COMPUTER NETWORK JACK 41 SWITCH SD SWITCH WITH DIMMER R. RELOCATE EXISTING E. EXISTING TO REMAIN N. NEW OUTLET OR LIGHT FIXTURE ARI ARC FAULT INTERRUPTER NOTE #6 SCOPE OF WORK: ELECTRICAL WORK CONSISTS OF WIRING A NEW RESIDENCE. WORK TO BE COMPLETED FOLLOWING THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE. ALL;,SMOKE DETECTORS SHOWN ARE NEW AND SHALL BE 120v BATTERY INTERCONNECTED, 36" MIN. AWAY FROM ANY AC SUPPLY REGyISTER TYPICAL. 400a COMBO MAIN BKR (2)#500MCM,(1)#250MCM & (1)#1/0 GROUND IN 3" COND. Ground-(1)#1/0 in 112" COND. TO CWP GROUND PNL 'B' 125amp AC DISCONNECTS 40a F40aTI 60a PNL 'A' 200amp 3/4" COND. 3#2 IN 1 1/4" 3#2/0 IN 1 1/2" COND. C ELECTRICAL RISER E o SCALE:NTS TYPE: LOAD CENTER PANEL: 'A' VOLTS: 120/208V - 1P 3W MOUNTING: RECESSED REPLACES EXISTING BUS: 200 AMP MAIN: 200 A MLO 10,000 A.I.C. LOAD: SEE LOAD CALC LOAD COND WIRE TRIP POLE DESCRIPTION DESCRIPTION POLE TRIP WIRE COND LOAD * MC 14 15 1 M. BEDROOM 1 2 M. BATH (GFCI) 1 20 12 .60 * 14 15 1 M. BEDROOM 3 4 M. CLO (GFCI) 1 20 12 .60 12 20 1 POWDER ROOM (GFI) 5 6 HALL 1 15 14 MC * 14 15 1 ENTRY/ STAIR HALL 7 8 WASHER 1 20 12 1.5 5.0 3/4 10 30 2 DRYER 9 10 REFRIGERATOR 1 20 12 1.0 11 12 APPLIANCE GFI (AFCI) 1 20 12 1.5 80 MC 12 20 1 DISPOSAL 13 14 APPLIANCE GFI (AFCI) 1 20 12 1.5 * 14 15 1 GREAT RM LED LIGHTS 15 16 DISHWASHER 1 20 12 1.2 * 14 15 1 GREAT RM FANS OUTLETS 17 18 FRONT PORCH (GFCI) 1 20 12 1.2 * 14 15 1 GREAT RM OUTLETS 19 20 OUTSIDE LIGHTS (GFCI) 1 15 14 5.0 1.5 12 20 1 GARAGE OUTLETS (CGFI) 21 22 GARAGE OPENERS (GFCI) 1 15 14 1 1.2 1.5 12 20 1 GARAGE OUTLETS (CGFI) 23 24 AHU UNIT #1 2 60 6 3/4 10.8 * 14 15 1 TANKLESS WATER 25 26 .60 12 20 1 SMOKE DETECTORS (GFI) 27 28 RANGE (GFI) 1 15 14 5.0 3/4 10 30 2 OVEN 29 30 31 32 33 34 35 36 37 38 39 40 * PART OF 3w/sf LOAD- SEE CALCULATIONS BELOW LOAD CALCULATION LIGHTS AND RECEPTACLES 1634sf X 3w/sf= .................4902va OTHER LOADS EXCEPT A/C ....................................... .......... 25200va 1st 10kva @ 1000/o=...................... ...................................... 10,000va 20102va @ 400/o=...................................................................8041va A/C @ 100%............................................................ ................ 10800va 28841/208v= 138.66amps q 1st ELECTRICAL PLAN E1 SCALE:3/16"=1'-O" GFI GROUND FAULT INTERRUPTER PRINTED March 3, 2022 N o' a ti 0 z z w 0 0 U 0 z 0 J_ m X w a 0 w w a wmarthur ��oo PO F ART yP-� s 0 AR0012074 � u ARCHITECT OF RECORD William F. Arthur AR-0012074 i 4) Co U ra S L_ s Q Cy)Ln i = M N M t X _0 t a O �- E I° LO O U N � c N 0` a` 01 U M M M ra i O i L O O U LL LL -0 j Co > U U zry N O U N O M c a)U + °z C: c •.p U Q � U LU 0 (1)� � � (nQ w °Qd' cQ t w dtf O O0 aILN raO Oz 0 Z0ON Z ELECTRICAL E-1. L ELECTRICAL NOTES: 1. CONTRACTOR SHAD COORDINATE ALL HIS WORK WITH OTHER TRADES IN ORDER TO FURNISH AND INSTALL ALL WIRING AND RACEWAYS. 2. PROVIDE ALL FINAL CONNECTIONS TO ALL EQUIPMENT AND APPLIANCES. 3. BALCONY RECEPTACLES TO BE GFI AND WEATHER PROOF. 4. COORDINATE LOCATION OF ALL DISCONNECT SWITCHES WITH OTHER TRADES TO ALLOW N.E.C. REQUIREMENT CLEARANCE. 5. CIRCUITS WIRING REQUIRED TO BE AS FOLLOWS: 120V-2WIRE (L-N); 120/24OV-3 WIRE (LL-N); 240V-2WIRE (LL). WHEN EQUIPMENT GROUND IS REQUIRED INCREASE CONDUIT SIZE AS REQUIRED. 6. ALL WIRING TO BE COPPER; THHN/THWN TYPE RUN IN CONDUIT (METALLIC TYPE EMT), ROMEX IS ACCEPTABLE WHERE PERMITTED BY CODE. 7. ALL DUPLEX RECEPTACLES IN EXTERIOR AREAS TO BE OF GFI TYPE AND WEATHER PROOF. 8. MINIMUM WIRE SIZE SHALL BE #12 THHN/THWN WITHT THE EXCEPTION OF 15A GENERAL LTG. AND RECEPTACLE BRANCH CIRCUITS WHICH ARE #14 THHN/THWN, UNLESS OTHERWISE NOTED. 9. CONDUCTORS #6 AWG AND LARGER SHALL BE THW. 10. ALL CONDUCTORS SHALL BE COPPER. 11. CONDUIT IN FINISHED AREAS SHALL BE CONCEALED. 12. CONDUIT IN UNFINISHED AREAS SHALL BE EXPOSED. 13. FUSES SHALL BE DUAL ELEMENT, TIME DELAY TYPE, 14. INSTALL NYLON PULL STRING IN ALL EMPTY CONDUITS FOR FUTURE USE. 15. ALL MATERIALS SHALL BE U.L. APPROVED. 16. WORKMANSHIP SHALL BE TO BEST COMMERCIAL PRACTICE. 17. INSTALLATION SHALL BE IN ACCORDANCE WITH LOCAL, STATE AND NATIONAL CODES. 18. ALL LUMINARES SHALL BE PROPERLY SUPPORTED IN ACCORDANCE WITH THE CEILING SYSTEM MANUFACTURER'S RECOMMENDATIONS AND LOCAL CODE REQUIREMENTS. 19. ALL DEVICES SHALL BE PER BUILDING STANDARD AND SHALL MATCH EXISTING. 20. THIS DRAWING IS A GUIDE FOR THE INSTALLATION OF ELECTRICAL SERVICE. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE A FUNCTIONING SYSTEM. 21. COORDINATE CONDUIT REQUIREMENTS WITH SPEAKER, TELEPHONE, LOW VOLTAGE AND CABLE CONTRACTORS. 22. ALL BRANCH CIRCUITS SERVING DINING ROOM, LIVING ROOM, BEDROOMS, OFFICE, CLOSETS AND HALLWAYS (EXCEPT BATHROOMS) SHALL BE PROTECTED BY LISTED AFCI TYPE BREAKERS PER NEC 2014, SEC. 210.12. 23. PROVIDE LISTED TAMPER RESISTANT RECEPTACLES IN KITCHEN, DINING ROOM, LIVING ROOM, OFFICE AND BEDROOMS. ELECTRICAL LEGEND WALL SCONCE ❑❑ RECESSED LIGHT FIXTURE �❑ vp VAPOR PROOF LIGHT FIXTURE JUNCTION BOX EXIT LIGHT SD SMOKE DETECTOR W/BATTERY BACKUP EF EXHAUST FAN [Ls LIGHT STROBE �P PULL STATION ® BOOSTER FAN RECESSED SPEAKER BUILDING SPEAKER DUPLEX OUTLET-15A,125V,3 WIRE MOUNTED @ 18" AFF. SMALL APPLIANCE, BATH DUPLEX SHALL BE 20A, 125V, 3 WIRE,GROUND TYPE WALL MOUNTED, ABOVE COUNTER UNLESS OTHERWISE NOTED. EXISTING DUPLEX OUTLET -DO NOT DISTURB .„.% OUTLET REMOVED AT DEMOLITION SPECIAL PURPOSE OUTLET 240V TELEPHONE JACK COMPUTER NETWORK JACK SWITCH �D SWITCH WITH DIMMER R. RELOCATE EXISTING E. EXISTING TO REMAIN N. NEW OUTLET OR LIGHT FIXTURE ARI ARC FAULT INTERRUPTER GFI GROUND FAULT INTERRUPTER SCOPE OF WORK: ELECTRICAL WORK CONSISTS OF WIRING A NEW RESIDENCE. WORK TO BE COMPLETED FOLLOWING THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE. NOTE: ALL SMOKE DETECTORS SHOWN ARE NEW AND SHALL BE 120v BATTERY INTERCONNECTED, 36" MIN. AWAY FROM ANY AC SUPPLY REGISTER TYPICAL. 400a COMBO O MAIN B R 400. (2)#500MCM, (1)#290MCM 3#2 IN & (1)#1/0 GROUND 1 1/4" IN 3" COND. 3#2/0IN 1 1/2' COND. Ground-(1)#1/0 in COND. TO CWP GROUND PNL IS, 125amp PNL 'A' 200amp AC DISCONNECTS N 40a 0a N 160a 3/4" COND. C ELECTRICAL RISER E1,0 SCALE: NTS TYPE: LOAD CEN MOUNTING: RECESSED MAIN: 200 A MILO ER PANEL: 'A' VOLTS: REPLACES EXISTING BUS: 10,000 A.I.C. LOAD: LOAD COND WIRE TRIP POLE DESCRIPTION DESCRIPTION POLE * MC 14 15 1 M. BEDROOM 1 2 M. BATH (GFCI) 1 * 14 15 1 M. BEDROOM 3 4 M. CLO (GFCI) 1 .60 12 26 1 POWDER ROOM (GFI) 5 6 HALL 1 * 14 15 1 ENTRY/ STAIR HALL 7 8 WASHER 1 5.0 3/4 10 30 2 DRYER 9 10 REFRIGERATOR 1 11 12 1 APPLIANCE GFI (AFCI) 1 '80 MC 12 201 1 DISPOSAL 13 14 APPLIANCE GFI (AFCI) I * 14 15 1 GREAT RM LED LIGHTS 15 16 DISHWASHER 1 * 14 15 1 GREAT RM FANS OUTLETS 17 18 FRONT PORCH (GFCI) 1 * 14 15 1 GREAT RM OUTLETS 19 20 OUTSIDE LIGHTS (GFCI) 1 1.5 12 20 1 GARAGE OUTLETS (CGFI) 21 22 GARAGE OPENERS (GFCI) 1 1.5 12 20 1 GARAGE OUTLETS (CGFI) 23 24 AHU UNIT #1 2 * 14 15 1 TANKLESS WATER 25 26 .60 12 201, 1 SMOKE DETECTORS (GFI) 27 28 RANGE (GFI) 1 5.0 3/4 10 3d 2 OVEN 29 30 31 32 33 34 35 36 37 38 39 40 * PART OF 3w/sf LOAq- SEE CALCULATIONS BELOW LOAD CALCULATION UNDERGROUND SERVICE PROPANE TANKLESS INSIDE UNIT- INSTALL VENT PER MF'G RECOMMENDATIONS SEE INFO IN PROJECT BOOKLET MAIN BRK COMBO W/ METER 131 ,12 B1 A23 GFI TO PANEL'B A25 GFI I GFI GFI 11 _ TO PANEL'A' -- ° A21 -__ _- - A21 - 'AFI GFI _ -- GFI ' TG A7 STAIR UPSTAIRS '\ SD's SD A27 GFI ------ --- A] I I }._.... AN I I I I - I i I I I 120/208V 200 SEE AMP LOAD - 1P 3W CALC oh RIP WIRE COND LOAD 20 12 .60 20 12 15 14 MC 20 12 1.5 20 12 1.0 20 12 1.5 20 12 1.5", 20 12 1.2 20 12 1.2 15 14 50 15 14 1.2 60 6 3/4 10.8 15 14 LIGHTS AND RECEPTACLES 1634sf X 3w/sf= ................ .4902va OTHER LOADS EXCEPT A/C.................................................25200va 1st 10kva @ 100%=............................................................10,000va 20102va @ 400/G=...................................................................8041va A/C @ 100%.............................. .............................................. 10800va 28841/208v= 138.66amps DRYER A7 I q�; � &= _ L°�" ENTiI CA A22 II A7 AFI GFI 71, A7 1 A2/4, _______________ GFI AGOT �`C 9TAFF I 1 _ 2 l 1 ; A3 AFI M.BED�OI n " A tl A4 P] A4 nAFI GFI GFI GFI (IT)A,-; As AFI db AFI SID AFI 1 GFI II A 0 ... _ HALL Ae AFI AR n" AFI AR......}� I Al, I _ pAF A I UHF A6, It` A18 AFI 01 ��FI _Al2 M I C.0 GFI I \FI AJr--' 0 A3 AFI A3 AFI I A16 GFI / A17` A / Al A ,� A17 E-( AR I AF I. AFI I AFI ----- --------- '-1""_ � / AFI q 1st ELECTRICAL PLAN E1 SCALE:3/16"=1'-0" PRINTED March 5, 2021 41 wmarthur ARCHITECT OF RECORD William F. Arthur AR-0012074 i W ^U^`` W a-CLO i N M -C O Q C u- E (O N `- U - O N N c N CL os I 01 M I O O U . CO N �m U w O N U ' U N z o � m � a �z N U �ULw � C U Q� Q Q c~i O Q� s t w " p 0_N Z00N ) CTRICAL E-�. TYPE: LOAD CENTER NEW SUB -PANEL: 'B' VOLTS: 120/208V - 1P 3W MOUNTING: RECESSED REPLACES EXISTING BUS: 125 AMP MAIN: 125 A MLO 10,000 A.I.C. LOAD: SEE LOAD CALC LOAD COND WIRE TRIP POLE DESCRIPTION DESCRIPTION POLE TRIP WIRE COND LOAD * MC 14 15 1 BEDROOM 2 (AFCI) 1 2 BATHROOM 2 GFI (AFCI) 1 20 12 MC .60 * 14 15 1 BEDROOM 3 (AFCI) 3 4 HALLWAY (AFCI) 1 15 14 * 14 15 1 STAIRWELL (AFCI) 5 6 UPPER LEVEL (AFCI) 1 15 14 * 14 15 1 CLG FANS (AFCI) 7 8 UPPER LEVEL (AFCI) 1 15 14 * 14 15 1 UPPER LEVEL (AFCI) 9 10 AC UNIT 2 20 12 1/2 5.2 5.2 1/2 12 20 2 AC UNIT 11t12 13 14 SPACE SPACE 15 16 SPACE 17 18 19 20 21 22 23 24 * PART OF 3w/sf LOAD- SEE CALCULATIONS BELOW LOAD CALCULATION LIGHTS AND RECEPTACLES 1208sf X 3w/sf= ...... ........... 3624va OTHER LOADS EXCEPT A/C.....................................................600va 1st 10kva @ 1000/o=................ .............. .......... ............. ........... 4224va 23101va @ 400/o=............................ ............................................ O.Ova A/C '@ 100%............................................................................10,400va 14224/208v= 69.Oamps— _ g 3rd ELECTRICAL PLAN E2 SCALE:3/16"=1'-O" q 2nd ELECTRICAL PLAN E2 SCALE; 3/16"=1'-O" PRINTED March 5, 2021 Amok � ih wmarthur F F M Foq RT'y O o * AR0012 74 G 0 sr �.o o�, t � � � ) AacN ARCHITECT OF RECORD William F. Arthur AR-0012074 L Q) \m U t " 0 Lo Q '� r = M � O M t O a 4-U_ E ° N 0 — O U N � C O_ 01 0 CM M O O O LL. ILL c>-O >� C C N s N N s 03 Ln U)U U z N O U N O O m C (o M C a)C t c Z3 �Z U Q t CoLU �4 _ Q C Q _ c~i O s W a wtf 0 0 0 O t O 1 ra aELN Z00N O Z ELECTRICAL E-2.0ve 15v CAP, PLUMBING NOTES: 1. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 6th EDITION 2017. 2. BUILDING DRAINAGE SYSTEM TO BE SLOPED AT MIN. 1/8" PER FOOT FOR 3" PIPES AND LARGER,1/4" PER FT. FOR 2" PIPE SIZE. SMALLER DEVIATIONS SHALL BE APPROVED BY ARCHITECT. 3. PROVIDE CLEAN -OUTS EVERY 75' AND AT BASE OF EVERY WASTE STACK. ALL CLEAN -OUTS TO BE FLUSH MOUNTED. 4. ALL MATERIALS SHALL BE NEW AND AS FOLLOWS: A. DRAINAGE WASTE AND VENT PIPING (INCLUDING PVC) SHALL CONFORM TO ASTM D-2665, UNDERGROUND NO HUB CAST IRON CISPI STANDARD 301. ABOVE GROUND AND CAST IRON HUB, PLAIN END AS PER ASTM A-74 WITH NEOPRENE GASKETS UNDERGROUND. INSTALL PLASTIC (PVC) PIPES ONLY WHEN IT IS APPROVED BY LOCAL AUTHORITIES AND IT IS NOT TO BE USED IN AIR RETURN PLENUM. B. WATER PIPING SHALL BE COPPER TYPE 'L' PER ASTM B-88 ABOVE GROUND AND COPPER TYPE TYPE'K' PER ASTM B-88 UNDERGROUND. C. WALL CLEAN OUTS SHALL BE JOSAM SERIES 58750 (OR EQUAL) WITH ACCESS COVER. D. VALVES SHALL BE 125psi NIBCO SCOTT, STOCKHAM OR EQUAL. 5. PLUMBING CONTRACTOR SHALL PERFORM THE FOLLOWING TEST: A. WATER PIPING SHALL BE SUBJECTED TO HYDROSTATIC PRESSURE TEST OF 100 PSIG FOR A PERIOD OF TIME SUFFICIENT TO EXAMINE ENTIRE SYSTEM BUT NOT LESS THAN ONE HOUR, B. DRAINAGE SYSTEM: BEFORE INSTALLATION OF ANY DRAINS, THE END OF THE SYSTEM SHALL BE CAPPED AND ALL LINES FILLED WITH WATER OT HIGHEST POINT & ALLOWED TO STAND UNTIL INSPECTION IS MADE AND WATER LEVELS REMAIN CONSTANT. C. CORRECT ALL DEFECTS DISCLOSED BY ABOVE TESTS. D. COMPLETE SYSTEM, FIXTURES & EQUIPMENT, SHALL BE GIVEN AN IN SERVICE TEST AFTER COMPLETION OF THE INSTALLATION. E. STERILIZE ALL WATER LINES WITH A MIXTURE OF (2) TWO POUNDS OF CHLORINATED LIME TO EACH 1000gal OF WATER (50PPM OF AVAILABLE CHLORINE). RETAIN MIXTURE IN PIPES FOR 24 HOURS AND FLUSH THOROUGHLY WITH POTABLE WATER BEFORE PLACING IN SERVICE. 6. PLUMBING CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE THAT ALL PLUMBING WORK SHALL BE FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE, AND THAT HE WILL, AT HIS EXPENSE, REPAIR AND REPLACE ALL WORK WHICH BECOMES DEFECTIVE DURING GUARANTEE PERIOD. 7. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION OF EXISTING UTILITIES AND POINTS OF CONNECTION BEFORE COMMENCING WITH ANY WORK. 8. PLUMBING CONTRACTOR SHALL PAY ALL FEES, INSPECTIONS AND CONNECTION CHARGES REQUIRED FOR THE PROJECT. 9. SUBMIT SHOP DRAWINGS TO ARCHITECT FOR APPROVAL OF ALL EQUIPMENT, MATERIALS AND LAYOUTS PRIOR TO INSTALLATION. 10, OFFSET PIPING AS REQUIRED TO CLEAR BUILDING STRUCTURE, DUCTWORK, ETC., AS SHOWN OF DRAWINGS AND AS REQUIRED BY FIELD CONDITIONS. 11. PLUMBING CONTRACTOR SHALL VERIFY ALL SPACE CONDITIONS AND DIMENSIONS AT JOB SITE PRIOR TO FABRICATION AND INSTALLATION OF MATERIALS AND EQUIPMENT. 12. PLUMBING CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER TRADES. 13. FURNISH AND INSTALL ALL FIXTURES AS SPECIFIED ON THESE DRAWINGS AND SCHEDULES. 14. EACH BATHROOM GROUP SHALL BE PROVIDED WITH SHOCK ABSORBERS PER FLORIDA BUILDING CODE. 15. PROVIDE SHUTOFF VALVE FOR EACH FIXTURE, JUST BEFOR INSTALLING THE FIXTURE. 16. WHEREVER DISSIMILAR METALS ARE TO BE JOINED, A DIELECTRIC FITTING SHALL BE PROVIDED TO CONNECT BOTH TYPES OF PIPES. 17. PROVIDE PIPE INSULATION AS FOLLOWS: A. ALL CONDENSATE LINES SHALL BE INSULATED WITH 3/4" FIRE RETARDANT 'ARMAFLEX' INSULATION WITH MAXIMUM OF 25/50 FLAME SPREAD AND SMOKE DEVELOPED RESPECTIVELY. B. ALL HOT WATER LINES SHALL BE INSULATED WITH 1" FIRE RETARDANT 'ARMAFLEX' INSULATION WITH A MAXIMUM OF 25/50 FLAME SPREAD AND SMOKE DEVELOPED RESPECTIVELY. ALL FIXTURES SHALL COMPLY WITH FBC P 2017 AND PER BELOW: SINKS & LAVATORIES SINKS SHALL BE PROVIDED WITH A MIN. WASTE OUTLET OF 1 1/2 IN DIAMETER. A STRAINER OR CROSSBAR SHALL BE PROVIDED TO RESTRICT CLEAR OPENING. WATER CLOSETS SHALL CONFORM WITH FBC P 604.4 FOR CONSUMPTION REQUIREMENTS WATER CLOSET SEATS SHALL BE SMOOTH, NONABSORBENT MATERIAL, HINGED AND SIZED FOR THE WATER CLOSET BOWL TYPE. CONNECTION SHALL BE 4"x3" CLOSET BEND SHOWERS SHOWERS SHALL COMPLY WITH REQUIREMENTS OF FBC 424.3. WATER SUPPLY RISERS SHALL BE FASTENED TO THE STRUCTURE USING DEVICES DESIGNED FOR THE SPECIFIC PIPING MATERIAL OR BY FITTINGS ANCHORED WITH SCREWS. WASTE OUTLETS TO BE A MIN. OF 1 1/2" AND SHALL HAVE REMOVABLE STRAINERS OF 3" IN DIAMETER WITH OPENINGS NOT LESS THAN 3/4" IN DIAMETER. SHOWER COMPARTMENTS SHALL COMPLY WITH 417.4 AND WALL AREA SHALL BE CONSTRUCTED OF SMOOTH NONCORROSIVE AND NON - ABSORBENT WATERPROOF MATERIALS TO A MIN. HEIGHT OF 6' ABOVE THE DRAIN HEIGHT. FLOOR SURFACES SHALL BE CONSTRUCTED OF IMPERVIOUS NOW CORROSIVE NONABSORBENT WATERPROOF MATERIALS. SHOWER LINING SHALL BE INSTALLED PER TYPICAL DETAILS SHOWN ON SHEET A2.0 FIXTURES SHALL COMPLY WITH WATER CONSUMPTION REQUIREMENTS AS OUTLINED IN MIAMI-DADE COUNTY CODE 08-31. PLUMBING FIXTURE CONNECTION SCHEDULE MARK DESCRIPTION WASTE C.W. H.W. REMARKS P1 WATER CLOSET 3" 1/2 " - GEBERT WALL HUNG, DUAL FLUSH TANK REAR DISCHARGE 02 SHOWER 2" 1/2 " ANTI -SCALD, PRESSURE BALANCING VALVE P3 LAVATORY 2" 1/2 " COUNTERTOP P4 KITCHEN SINK 2" 1/2" DOUBLE COMPARTMENT REF REFRIGERATOR - - PROVIDE SHUTOFF VALVE WM IWASHER 3" 1/2 / INDIRECT CONNECTION TO I HUB DRAIN NOTES: 1. PLUMBING FIXTURES AND TRIM TO BE SELECTED BY OWNER. 2. MAXIMUM WATER CONSUMPTION FLOW RATES AND QUANTITIES FOR ALL PLUMBING FIXTURES AND FIXTURE FITTINGS SHALL BE IN ACCORDANCE WITH ORDINANCE 8.31 OF MIAMI-DADE COUNTY. 3. ALL PLUMBING FIXTURES SHALL COMPLY WITH THE FLORIDA BUILDING CODE, CHAPTER 4 OF THE PLUMBING CODE PER SECTION 406 THRU 421. MAXIMUM FLOW RATES & CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS PLUMBING FIXTURE OR FIXTURE FITTING RATES LAVATORY FAUCET 1.5 gal @ 60 si SHOWER HEAD 1.5 gal @ 80 si SINK FAUCET 1.5 gal @ 60 si WATER CLOSET 1.28 gal per flush PLUMBING SCOPE OF WORK THE WORK ENCOMPASSES CONSTRUCTING A NEW 2842sf COTTAGE. GENERALLY, ALL HOTAND COLD WATER PIPING CAN BE'PEX', HOWEVER THE OWNER WILL MAKE THIS FINAL DETERMINATION. A NEW 250 GAL -PROPANE TANK WILL BE INSTALLED UNDERGROUND AND USING 1/2" POLYETHYLENE PIPE TO SECONDARY REGULATOR. BLACK IRON PIPE WILL BE USED TO CONSTRUCTA MANIFOLD IN GARAGE. CSST PIPING AND FITTINGS WILL SUPPLY EACH APPLIANCE, WITH THE EXCEPTION OF THE OUTDOOR TANKLESS WATER HEATER, WHICH WILL BE SUPPLIED WITH BLACK IRON PIPE. APPLIANCES INCLUDE GAS COOKTOP, A TANKLESS WATER HEATER, A'JOTEL' STOVE AND A BBQ ON THE REAR PORCH. ALLAPPLIANCES WILL HAVE BRONZE SHUT-OFF VALVES. ISOLATORS WILL BE USED IF FIELD CONDITIONS DICTATE. THE INTERIOR TANKLESS WATER HEATER WILL BE SUPPLIED WITH A 3/4" COPPER COLD WATER LINE FROM A MANIFOLD LOCATED NEAR THE WASHER AND DRYER AREA. THE TANKLESS WATER HEATER WILL DISCHARGE HOT WATER THRU A 3/4" R-3 INSULATED COPPER LINES TO THE BATHROOM. A 1/2"'PEX' LINE WILL SUPPLY THE KITCHEN SINK FROM THE MANIFOLD. A 1st PLUMBING PLAN P1 SCALE:3/16"=1'-0" BOTTOM OF II DRAINFIELD +5.46' NAVD X wmarthur ARCHITECT OF RECORD William F. Arthur AR-0012074 L N \m U t -C� L a' Q = _ M i N M X z t Q 1 O U_ C (0 uI - - O � U N N C: d. O^ C^ d' M L O L O ti LL U L N In CK U t (n U U N z O a) N in O M ~ z 'HU'.,'4- C � o C: U Q 0 U U Q C Q O Q d Lu N d O O CD Z C:) C:)aILN Z o 0 N PLUMBING SHOWER VALVE SHALL BE BALANCE -PRESSURE THERMOSTATIC VALVE THAT CONFORM TO THE REQUIREMENTS OF ASSE 1015, ASME Al12.18,1/CSA B125.1 AND SHALL BE INSTALLED AT THE POINT OF USE. SHOWER VALVE SHALL LIMIT THE MAXIMUM SETTING TO 120 DEGREES F (49 DEGREES C) WHICH SHALL BE FIELD ADJUSTED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS PRINTED March 5, 2021 �1 0°;01 .o . GPM 'GPM i - -. FGAS NIHYIBEfl MIN. FLOWl 68/° ®46° CONNECTIONSHIP ERMODEL MPUT OF TEMP. ACTIVATION RISE RI$E MAX. VENT WEXNIT CTNUMBER 7FA BTU/H TYPE BATHROOMS"" RANGE GPM : MAX. MAX. GPM f WATER GA3 HEI(iH7 YADTH DEPTH OIAM.UEFi RTGH-95DVELN-1 11,000- Indoor j 4 85° to 0.26/0.40 5.7 8.5 9.5 3/4 3/4 27-1/2 18-1/2 9-3/4 82 0.93 (EcoNetO lnciudecil 199,900 Direct Vent 140° F l PVC2 Pipe 314" BLACK GAS SUPPL 11,000- 850 to Outdoor . N/A 82 0.93 SHUT OFFRTGH-95XELN-1 <== (EcoNe• Inewdedl 1 140° F , , 14 PSIG Line Sizing Chart -Polyethylene Tubing- 10 PSIG inlet with a 1 PSIG Pressure Drop Maximum capacity of plastic tubing in thousands of BTU/hr of LP -Gas Size of 1 LengthofTut)ing,Fee1 Plastic Tubing NPS SDR 10, 20 30 40 50 60 70 80 90 100 1/2 CTS 7.00 954 766 655 581 526 484 450 423 399 1/2 IPS 9.33 3901 2681 2153 1843 1633 1480 1361 1267 1188 1122 3/4 IPS 11.00 5369 4311 3690 3270 2693 2726 2536 2379 2248 1 CTS 11.50 9510 6536 5249 4492 3981 3607 3319 3088 2897 2736 1 CTS 12,50 10002 6874 552D 4725 4187 3794 3490 3247 3046 2878 1 IPS 11.00 14094 9687 7779 6668 5901 5346 4919 4578 4293 4055 1 ti4 IPS 10.00 24416 16781 13476 11534 10222 9262 8521 7927 7438 7026 2 IPS 11.00 66251 45534 36666 31295 27737 25131 23120 21509 20181 19063 112 CTS 7.00 354 321 295 274 257 243 231 220 203 189 1/2 IPS 9.33 995 901 829 772 724 684 649 620 570 530 3/4 IPS 11.00 1992 1805 1660 1545 1449 1369 1300 1241 1141 1062 1 CTS 11.50 2425 2197 2022 1881 1765 1667 1583 1510 1389 1293 1 CTS 12.50 2551 2311 2126 1978 1856 1753 1665 1588 1461 1359 1 IPS 11.00 3594 3257 2996 2787 2615 2470 2346 2238 2059 1916 "/4 IPS 10.00 6226 5642 5190 4829 4531 4280 4064 3878 3567 3318 2 IPS 11.00 16895 15308 14084 13102 12293 11612 11028 10521 9680 9005 Data Calculated per NFPA #58 & #54 Table 7-18 Maximum Capacity of Gastire'/Flash$hield— Flexible Gas Piping in Thousands of BTU Per Hour of Liquefied Petroleum Gas with a Gas Pressure of 2.0 psi or Less and a Pressure Drop of 1.0"PSI (ha=Cd on a L52 speci6. orari�c L1' snsl Tubing InbingL:n-th(h) _ ETID Stu 5 10 15 20 27 3G 40 60 70 80 90 100 12 T50 13.-: 3/87. 621 430 347 298 265 241 207 184 167 15!1 143 135 127 113 103 18 = 1/27 , 1516 1077 882 765 685 626 543 445 412 386 364 346 310 283 23 3/4",= 2530 1840 1527 1338 1208 till 973 879 808 753 708 671 639 577 530 6346 4548 3743 3259 2928 2682 2336 2098 1922 1785 1674 1582 1504 1351 1237 37 ( 1,1740, s9937 7074 5798 5036 4514 4128 3585 3213 2938 2725 2552 2409 2287 2050 1875 47 1-T/2" 2L129 1501G 12297 10672 9561 8739 7584 6795 6211 5756 5390 5086 4529 4326 3954 60. 2" r 48882 34199 27750 23926 21327 19415 16739 14921 13583 1254 11711 11022 10439 9305 8471 Iitlaittg ubii*-length (h), EHD' - Siu 200,' .25Q W';_ ,40p 50J?,. :600, '2700 •$g0 900, 1 1000 1100, `1200 1300 ;1400 1500 13 �= 3/8" 88 78 71 61 54 49 45 42 40 1 38 36 34 33 31 30 ., 1 ; � 1/2- 24 6 220 201 174 156 143 132 124 117 Ill 106 )01 97 94 91 ' 23 )� 3/4" 465 420 386 338 305 281g1851 246 233 222 212 204 197 190 184 31 1" 1078 968 887 772 694 636553 523 497 475 455 438 423 409 37 ` TI/4" E 1628 1460 1335 1159 1039 950825 779 740 706 676 650 627 606 47 `� 1-112" 3432 3074 2810 2439 2185 1991733 1636 1553 1482 1419 1365 1316 1272 60, " 7303 6510 5926 5110 4555 4143575 3364 318G 3034 2901 2783 2679 258G Tables include losses for four 90" bends and two end fittings. Tubing runs with a larger number of bends and/or fittings shall be increased by an equivalent length of tubing to the following equation: L=1.3n where L is additional length of tubing and n is the number of additional fittings and/or bends. 1 1/4" PVC CITY WATER SUPPLY W/ BRONZE SHUT OFF VALVE TO HOUSE V 3rd PLUMBING PLAN P2)SCALE:3/16"=1'-0" GRADE 250 GAL UNDERGROUND PROPANE TANK -STRAP TO PREVENT UPLIFT DO TO HYDRO -STATIC PRESSURE C (PROPANE TANK & TANKLESS SCHEMATIC P1.O J SCALE: NITS -3' PVC I ROM BELOW TO VTR ABOVE STOVE 24,000 BTU's A 2nd PLUMBING PLAN P2 SCALE:3/16"=1'-0" wmarthur g AR0012074 ARCHITECT OF RECORD William F. Arthur AR-00121 m U U Q = M L a) M X � Q LL (n0 U) 0 U — N � C N tL 01 O� OI O> M let M t6 OS O O _O LL LL U i a) m to -C to U a) S N U (6 to (a o � a)O C t6 U a) C O tc m NUIZ c 4 (> Z C t c+�—,s W iV-, z tn Q C Q U O w Q O t w O s t O to O aCLN Z00((N Z LIA4I1IeIM PRINTED ��`�'t�2'0 March 5, 2021 SPECIFICATIONS INSTIR'UCTION TO (BIDDERS SECTION OOTOO NA DOCUMENT A701. INSTRUCTIONS TO BIDDER'S;,. 1987 EDITION IS THE FORM EVJNG USED. COPIES OF THIS DOCUMENT MAY BE OBTAINED FROM THE OFFICE OF THE ARCHITECT BEFORE PROCEEDING WITH WORK. 'SUPPLEMENT TO THE INSTRUCTIONS TO BIDDERS L AT THE END OF SUBPARAGRAPH32.1. ADD; 3,2,1,T, THE CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AT THE SITE AND 'SHALL BE RESPONSIBLE FOR ADAPTING THE PLAN TO ExISTINO CONDITIONS- IN THE CASE OF DISCREPANCIES BETWEEN THE DRAINGS AND THE EXISTING CONDITIONS, THEY SHALL BE REPORTED TO THE ARCHITECT.. SUPPLEMENTARY CONDITIONS SECTION 00800 AIA DOCUMENT A 201-1487 EDITION: 'GENERAL CONDITIONS OF THE CONTRACT' FOR CONSTRUCTION` IS HEREBY INCLUDED AS A 'PART' OF THE -CONTRACT DOCUMENTS IBY REFERENCE - SUPPLEMENTS TO THE "GENERAL CONDITIONS" AS REQUIRED, WILL BE WRITTEN BY THE ARCHITECT OF RECORD. ERRORS AND OMISSIONS FjRRORS. INCONSISTENCIES. AND OR AMBIGUITIES SHALL BE BROUGHT TO THE ARCHITECTS ATTENTION IMMEDIATELY, AND SHALL NOT BE CONSIDERED 'SUFFICIENT REASON TO DEPART FROM THE DESIGN INTENT OF THE CONSTRUCTION: DOCUMENTS. SUMMARY Of WORK, SECTION O1,OTO NOT USED CONSTRUCTION SCHEDULE, THE CONTRACTOR' SHALL PREPARE AND SUBMIT TO THE OWNER AND ARCHITECT. A BAR CHART TYPE PROGRESS SCHEDULE FOR THE ENTIRE PROJECT, WITHIN'! THREE (3) DAYS AFTER AWARD OF CONTRACT, PROVIDE A. SEPARATE BAR FOR EACH 'WORK ITEM LISTED IN THE 'SCHEDULE OF VALUES. INCLUDE APPROPRIATE TIME FOR PROJECT MOBILIZATION PROCUREMENT OF PRODUCTS, REVIEW AND RETURN OF SHOP DRAWINGS. FABRICATION INSTALLATION. TESTING FINAL CLEANUP AND INSTALLATION TIME FOR WORK UNDER SEPARATE CONTRACTS, IDENTIFY EACH, CALENDAR DAY THROUGH -OUT THE SCHEDULE,HIGHLIGHT CRITICALI PATH ELEMENTS O F THE SCH EDULE THATE IMPORTANT TO COMPLETE THE WORK ON TIME. -- -- -... ARE - - - - - C- - - NTH THE DATE OF -CONTRACTOR PRIOR TO CONSTRUCTION, THE GENERAL CONTRACTOR, ARCHITECT OWNERSHIP SHALL MEET ON SITE TO DISCUSS :STAGING LOCATION(S) OF THE FOLLOWING,, DUMIPSTER CONTAINERS �IATERIALS & EQUIPMENT CREW. VENDOR & SUPPLIER PARKING. WORK HOURS PROVISIONS, FOR ALL OF THE ABOVE SHALL BE INCLUDED IN BID,, COORDINATE THE WORK OF THE COMPLETE PROJECT TO ASSURE. AN EFFICIENT AND ORDERLY SEQUENCE OF INSTALLATION OF CONSTRUCTMN ELEMENTS. AND FOR INSTALLATION OF ITEMS FURNISHED AND INSTALLED BY OTHERS, WITH PROVISIONS FOR ACCOMMCCATING OTHER ITEMS TO BE INSTALLED LATER. COORDINATE 'PACE REQUIREMENTS AND INSTALLATION OF MECHANICAL AND ELECTRICAL WORK WHICH ARE INDICATED DIAGRAMMATICALLY ON THE 'DRAWIINGS. UTILIZE SPACE EFFICIENTLY TO MAXIMIZE ACCESSIBILITY FOR OTHER INSTALLATIONS, AND FOR MAINTENANCE.. MAINTENANCE OF CONSTRUCTION DOCUMENT'S: THE CONTRACTOR SHALL (MAINTAIN AT THE PROJECT SITE, A "RECORD" SET OF CONSTRUCTION IDOCUMENTS AND THE FOLLOWING RELATED DRAWINGS OR DOCUMENTS TS PREPARED BY 'OTHERS: CASEWORK SHOP DRAWINGS PREPARED BY THE CASEWORK FABRICATOR INTERIOR AND EXTERIOR SIGNAGE SHOP DRAWINGS. IBY THE SIGNNAGE CONTRACTOR, AND ANY OTHER' SHOP DRAWINGS REQUIRED TO PERFORM WORK. DO NOT CONSTRUCT ANY PORTION OF THE WORK RELATED TO THESE (DRAWINGS AT ANY TIME WITHOUT SUCH DRAWINGS BEING AVAILABLE AT THE [PROJECT SITE. AND ONLY AFTER APPROVAL BY ARCHITECT5 OFFICE. APPLICATION FOR PAYMENT SECTION 01025 PAYMENT REOUESTS: THE PAYMENT REQUEST CYCLE IS TO BE REGULAR. EACH APPUCA11CHN MUST BE CONSISTENT WITH PREVIOUS APPLICATIONS AND PAYMENTS. CERTAIN APPLICATIONS FOR PAYMENT, SUCH AS TfE INITIAL APPLICATION, THE APPLICATION AT SUBSTANTIAL COMPLETION, AND THE FINAL PAYMENT APPLICATION INVOLVE ADDITIONAL RE'OUIREMENTS. PRIOR TO SUBMITTAL OF INITIAL APPLICATION FOR PAYMENT. THE FOLLOWING ITEMS SHALL BE SUBMITTED: (1) LISTING OF' SUBCONTRACTOR AND PRINCIPAL SUPPLIERS AND FABRICATORS, (2') THE PROGRESS SCHEDULE, (3) PRELIMINARY SCHEDULE OF VALUES* (4) PERFORMANCE AND/OR PAYMENT BONDS, IF REQUIRED. AND (5) COPIES OF ACQUIRED !BUILDING PERMITS FOR iPERFORMANCE OF THE WORK. FORM AND QUANTITY APPLICATION: SUBMIT THREE (3) EXECUTED COPIES -OF AIA DOCUMENT G702. APPLICATION AND CERTIFICATION FOR PAYMENT. SUPPORTED BY AIA DOCUMENT G703. CONTINUATION SHEET, SUBMIT CONDITIONAL LIEN RELEASE$ WITH EACH APPLICATION FOR PAYMENT CONTINGENT UPON RECEIPT AND BANK CLEARANCE OF THE CURRENT LNVrOICED' AMOUNT, SUBMIT ,UNCONDITIONAL LIEN RELEASES COVERING THE PREVIOUSLY PAID AMOUNT RECEIVED BY THE GENERAL CONTRACTOR AND ALL SUB -CONTRACTORS OR MATERIAL SUPPLIERS WITH SUBSEQUENT APPLICATIONS FOR PAYMENT. (PRELIMINARY SCHEDULE OF VALUES: BEFORE START OF CONSTRUCTION. SUBMIT A PRELIMINARY SCHEDULE OF VALUES, SUPPORT WITH BACK-UP DATA TO SUBSTANTIATE, ITS ACCURACY UPON, REQUEST. (FINAL SCHEDULE OF VALUES: AT THE COMPLETION OF THE WORK, AS A CONDITION OF FINAL COMPLETION, SUBMIT A REVISED SCHEDULE OF VALLI REFLECTING THE FINAL COST OF THE WORK, INCLUDING ALL REVISIONS OR CHANGES MADE DURING CONSTRUCTION, ARRANGE SCHEDULE IN ORDER OF WORK ITEMS LISTED ABOVE, AND SUPPORT SCHEDULE WITH BACKUP DATA IF REOUESTEDO. SECTION 03200 CONTRACTOR 'SHALL PROVIDE THE ARCHITECT WITH SWOP DRAWINGS,. PRODUCT DATA AND SAMPLES FOR REVIEW(. SHOP DRAWINGS WILL REQUIRE A. MINIMUM OF 10 WORKING DAYS FOR REVIEW AND RETURN TO CONTRACTOR, TEMPORARY' FACILITIES/CONTROL SECTION 011500 CONNECT TO EXISTING SYSTEMS AT THE PROJECT SITE. AND COORDINATE WITH APPLICABLE UTILITY SERVICE COMPANIES. TO PROVIDE FOR WATER. ELECTRICAL POWER, LICHTING AND PHONE SERVICE COSTS FOR SUCH SERVICES SHALL BE INCLUDED IN THE BASE BID AMOUNT, UNLESS OTHERWISE INDICATED. ELECTRICAL POWDER SHALL BE UTILIZED FROM EXIST. SERVICE, CONSTRUCTION OPERATION5 REQUIRING POWDER„ USE OF POWER TOOLS. ELECTRICAL HEATING. LIGHTING, AND START-UP TES71 NG OF PERMANENT ELECTRIC - POWERED EQUIPMENT PRIOR TO ITS PERMANENT CONNEUON TO ELECTRICAL SYSTEM_ LOCATE MULTIPLE OUTLETS (MINIMUM OF 4-0AN0) SPACED SO THAT THE ENTIRE AREA OF CONSTRUCTION CAN BE REACHED BY POWER TOOLS ON A SINGLE EXTENSION CORD OF 5V MAXIMUM LENGTH, SANITARY FACILITIES: PROVIDE ON-5ITE T011LET FACILITY FOR THE USE TEMPORARY PHONE SERVICE: SHALL BE P"DED BY THE GENERAL CONTRACTOR, THE TEMPORARY TELEPHONE SHALL BE MADE AVAILABLE TO SUB -CONTRACTORS AND THE ARCHITECT OR CONSTRUCTION MANAGER OR HIS REPRESENTATIVE FOR LOCAL TELEPHONE CALLS, LONG DISTANCE. SHALL BE PAID FOR BY THE PARTY MAKING SUCH CALLS, SCAFFOLDING, PROVIDE .ALL SCAFFOLDING AND CONSTRUCTION AIDS REQUIRED. INCLUDING GUARD RAILS. LIGHTS AND PLATFORM$ NECESSARY FOR THE COMPLETION OF THE WORKMEN AND THE PUBLIC. PROGRESS CLEANING: AT ALL TIMES KEEP THE PROJECT SITE FREE FROM ACCUMULATION( OF WASTE MATERIALS OR RUBBISH CAUSED BY CONSTRUCTION DEBRIS, AND ARRANGE FOR TRANSPORTATION AND LEGAL DISPOSAL OF MATERIALS OFF SITE_ PRODUCTIONS & SUBSTITUTIONS SECTION 01600 PRODUCTS OPTIONS-. PRODUCTS SPECIFIED BY REFERENCE STANDARDS OR BY DESCRIPTION' ONLY. ANY PRODUCT MEETING THOSE STANDARDS OR DESCRIPTION PRODUCT'S SPECIFIED BY NAMING ONE OR MORE, MANUFACTURERS. PRODUCTS OF MANUFACTURER NAMED AND MEETING SPECIFICATIONS. NO OPTIONS OR SUOSIITU11ONS ALLOWED. PRODUCTS SPECIFIED BY NAMING ONE OR MORE MANUFACTURERS WITH A PROVISION FOR SUBSTITUTIONS- CDNTRACTOR"S SUBSTITUTION REPRESENTATTCNN: BY 'SUBSTITUTION OF A MATERIAL PRODUCT, EQUIPMENT ITEM OR 'SYSTEM, THE CONTRACTOR: (T) REPRESENTS THAT HE HAS PERSONALLY INVESTIGATED THE PROPOSED SUBSTITUTE [PRODUCT AND DETERMINED THAT IT IS EQUAL OR SUPERIOR IN ALL RESPECTS TO THAT SPECIFIED, (2.) WILL PROVIDE THE. SAME WARRANTY FOR THE SUBSTITUTION THAT THE CONTRACTOR WOULD:HAVE PROVIDED FOR THE SPECIFIED PRODUCT, (3) WAIVES ALL CLAIMS FOR AD017IONIAL COSTS RELATED TO THE SUBSTITUTION OF THE .ACCEPTED SUBSTITUTE MAKING SUCH CHANGES AS MAY BE REQUIRED FOR THE WORK TO BE COMPLETE IN ALL RESPECTS.- APPLICATION/ACCEPTANCE: APPLICATION OF A MATERIAL OR EQUIPMENT ITEM TO WORK INSTALLED BY OTHERS CONSTITUTES ACCEPTANCE OF THAT WORK AND ASSUMPTION OF FULL RESPONSIBILITY FOR SATISFACTORY INSTALLATION. PRODUCTS IN QUANTITIES 'SHALL BE ALIKE AND INTERCHANGEABLE. WHERE ADDITIONAL AMOUNTS OF A PRODUCT ARE LIKELY TO BE NEEDED BY THE OVI NER AT A LATER 'DATE FOR MAINTENANCE AND REPAIR, PROVIDE STANDARD, DOMESTICALLY PRODUCED PRODUCTS WHICH, ARE LIKELY TO BE AVAILABLE TO THE OWNER AT SUCH LATER DATE, SUPPLY PR DUCTSC0MP COMPLETE WTHALL STANDARD DEVICES. CES.1TIM FINISH, AND ALL ACCESSORIES INDICATED IN THE LATEST EDITION OF THE MANUFACTURER'S CATALOG OR BROCHURE iPUBLISHED AT THE, DATE. OF THE AWARD OF THE CONTRACT. FURNISH SUCH ITEMS COMPLETE WITH COMPONENT PARTS NECESSARY FOR THE OBVIOUS AND INTENDED USE AND INSTALLATION, WHETHER OR NOT DESCRIPTIONS OR CATALOG NUMBERS CONTAIN ALL SUPPLEMENTED INFORMATION .AND/OR NUMBERS OF SUCH COMPONENTS. EQUIPMENT NAMEPLATES: PROVIDE PERMANENT 'NAMEPLATES ON EACH ITEM OF SERVICE -CONNECTED OR POUR OPERATED EQUIPMENT. INDICATE. MANUFACTURER, PRODUCT NAME, MODEL NUMBER, SERIAL NUMBER, CAPACITY. SPEED, RATING, AND SIMILAR ESSENTIAL OPERATING DATA - LOCATE NAMEPLATES ON AN EASILY ACCESSIBLE SURFACE, LOCATE REQUIRED LABELS AND STAMPS, ON AN ACCESSIBLE SURFACE WHICH, IN OCCUPIED SPACE'S. IS NOT CONSPICUOUS, MANUFACTURER'S INSTRUCTIONS. WHENEVER PRODUCT'S ARE REQUIRED TO BE INSTALLED ANDjjOR PERFORM( IN ACCORDANCE WITH A SPECIFIED MANUFACTURERS INSTRUCTION OR PROCEDURE_ PROCURE. (DISTRIBUTE AND MAINTAIN AT 'THE STE COPIES OF SUCH INFORMATION„ NO ALLOWANCE OR CONSIDERATION ALL BE MADE FOR CLAIMED IGNORANCE AS TO WHAT A CITED REFERENCE STANDARD CONTAINS, AS EACH TRADESMAN IS CONSIDERED TO BE EXPERIENCED AND FAMILIAR WITH THE PUBLISHIED STANDARDS OF QUALITY AND WORKMANSHIP FOR HIS OWN TRADE. INSTALLERS INSPECTIONS: BEFORE INSTALLATION. INSPECT SUBSTRATE MATERIAL AND THE CONDITIONS UNDER 'WHICH THE WORK WILL BE PERFORMED. DO NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED- APPLICATION OF A MATERIAL OR EQUIPMENT ITEM TO WORK INSTALLED BY OTHERS CONSTITUTES ACCEPTANCE OF THAT WORK AND ASSUMPTION OF RESPONSIBILITY FOR SATISFACTORY INSTALLATION. INSPECT EACH ITEM OF MATERIAL. OR EQUIPMENT IMMEDIATELY PRIOR TO INSTALLATION - REJECT DAMAGED AN DEFECTIVE ITEMS, PERFORM INSTALLATION WORK. BY PERSONS QUALIFIED TO PRODUCE WORKMANSHIP OF SPECIFIED QUALITY, IN ACCORDANCE, WITH MANUFACTURER'S PRINTED INSTRUCTIONS, INSTALL WORK DURING CONDITIONS OF TEMPERATURE, HUMIDITY, EXPOSURE, FORECASTED WEATHER, AND STATUS OF THE PROJECT CCMPLETION WHICH ALL ENSURE THE BEST POSSIBLE RESULTS FOR EACH UNIT OF WORK. ISOLATE EACH UNIT OF WORK. FROM NON -COMPATIBLE WORK. AS REQUIRED TO PREVENT DETERIORATION, MAKE ALLOWANCES FOR EXPANSION,. CONTRACTION, AND BUILDING: MOVEMENTS- PROVIDE ATTACHMENT AND CONNECTION DEVICES AND METHODS FOR SECURING THE WORK PROPERLY AS IT IS INSTALLED, TRUE TO LINE AND LEVEL. PROVIDE UNIFORM JOINT WIDTHS IN EXPOSED WORK. ORGANIZED FOR BEST POSSIBLE VISUAL EFFECT. COORDINATE CLOSING -IN OF WOW NTH REQUIRED INSPECTIONS AND TESTS, SO AS TO MINIMIZE THE NECESSITY OF UNCOVEIRINC COMPLETED WORK. PROTECI t AFTER INSTALLATION(, PROVIDE COVERINGS TO PROTECT INSTALLED PRODUCTS FROM DAMAGE FROM TRAFFIC AND CONSTRUCTION OPERATIONS. REMOVE MEN NO LONGER REQUIRED. REPAIR AND REPLACE DAMAGED ITEMS, AT NO ADDITIONAL COST TO THE OWNER- ADDITIONAL TIME REQUIRED TO 'SECURE REPLACEMENTS AND TO MAKE REPAIRS WILL NOT BE CONSIDERED TO JUSTIFY AN EXTENSION OF TIME TO COMPLETE THE WORK. PROJECT' CLOSEOUT SECTION 01700 FINAL CLEANING, PRIOR 70 OWNER OCCUPANCY, CLEAN ALL SURFACES INCLUDING FIMRES AND EQUIPMENT. INCLUDING OWNER SUPPLEw EQLAPMIENT. REMOVE ALL TRACES OF SOIL, STAINS, .DIRT, (WASTE MATERIALS, SMUDGES. AND OTHER FOREIGN MATTER FROM ALL FINISHED SURFACE'S. 'CLEAN ALL EQUIPMENT AND FIXTURES TO A SANITARY CONDITION, CLEAN 'TRANSPARENT MATERIAL S, INCLUDING MWIRRORS AND GLASS IN DOORS WINOOWNS. AND CASEWORK. TO A POLISHED CONDITION, FREE OF DUST, PUTTY, FILMS OR SIMILAR SUBSTANCES WHICH ARE NOTICEABLE AS VISION -OBSCURING, SUBSTANTIAL COMPLETION: AFTER FINAL CLEANING OPERATT,IONS HAVE BEEN COMPLETED. AND WF1EN THE PROJECT 15 READY FOR OWNER OCCUPANCY, OBTAIN AN OCCUPANCY PERMIT ON BEHALF OF THE OWNER, AND APPROVAL BY ANY OTHER GOVERNMENTAL AUTHORITIES HAVING JURISDICTION OVER THEE PROJECT- SUBMIT ORIGINAL'S OF SUCH APPROVALS TO THE OWNER FOR HIS RECORDS. CERTIFICATE OF OCCUPANCY: CONTRACTOR SHALL OBTAIN CERTIFICATE OF OCCUPANCY, WHICH IS TO REMAIN IN THE POSSESSION OF THE [LEARNING CENTER'S HEAD MASTER WITH A COPY TO THE OWNER'S PROJECT REPRESENTATIVE. PUNCH LIST: THE GENERAL CONTRACTOR SHALL PREPARE A LIST OF WORK ITEMS YET TO BE COMPLETED OR CORRECTED COMPLETE WITH SCHEDULED DATES FOR COMPLETION, SUBMIT 71-IIS LIST TO THE ARCHITECT AND OIMINER' FOR REVIEW AND CQMIMENTS- THE ARCHITECT WILL THEN PERFORM A FINAL INSPECTION, AND WALL PREPARE A PUNCH LIST OF ITEMS WHICH ARE INCOMPLETE, DAMAGED, OR OTHERWISE NOT INN CONFORMANCE WITH THE REQUIREMENTS OF THE CONSTRUCTION ,DOCUMENTS. THE FAILURE TO INCLUDE ANY ITEM ON SUCH LIST DOES NOT ALTER THE RESPONSIBILITY OF THE CONTRACTOR TO COMPLETE ALL THE WORK REQUIRED BY THE CONSTRUCTION DOCUMENTS. INSTRUCTION TO PERSONNEL, FULLY INSTRUCT THE OWNER'S DESIGNATED PERSONNEL IN THE OPERATION., ADJUSTMENT, AND MAINTENANCE OF MECHANICAL,. PLUMBING, AND ELECTRICAL SYSTEMS. OPERATION AND MAINTENANCE DATA: ORGANIZE. TWO (2) SETS OF OPERATING AND MAINTENANCE DATA. BIND DATA IN HEAVY DUTY 3-INCH, 3-RING VINYL-COv€RED BINDER, PROPERLY IDENTIFIED AND INDEXED, INCLUDE THE FOLLOWING TYPES OF FNFORMATION IN OPERATING AND MAINTENANCE MANUALS: PAINT MATERIALS AND COLOR FORMULAS USED.; MATERIAL SUPPLIERS. AND PRODUCT IDENTIFICATIONS FOR FUTURE REPLACEMENT OF INTERIOR FINISHES, OPERATING MANUALS AND EMERGENCY INSTRUCTION'S FOR HVAC EQUIPMENT FURNISHED OD APPLICABLE). 'SPARE PARTS LISTINGS, COPIES OF WARRANTIES. HIRING DIAGRAMS. INSPECTION PROCEDURES. AIR TESTINC AND BALANCING REPORTS„ 'SUB -CONTRACTOR LISTING AND SIMILAR APPROPRIATE ITEMS. COMPLETE ALL WORK ITEMS AS EXPEDITIOUSLY AS POSSIBLE,. !PROVIDING LA13OR AT TIMES WHEN THE PROJECT' IS NOT IN OPERATION, IF NECESSARY.. COORDINATE WITH THE OWWNER"S MANAGER AND PERFORM THE WORK SO THAT IT WILL NOT INTERFERE WITH THE OIWNER'S OPERATIONS. FINAL. PAYMENT - CLOSEOUT SUBMITTALS: SUBMIT THE FOLLOWING ITEMS TO THE OWNER, UPON APPLICATION FOR FINAL PAYMENT: (1) FINAL OCCUPANCY PERMIT AND HEALTH DFFFIP'ARTM'ENT APPROVAL, WHEN REQUIRED: (2) UENN WAIVERS, (3) FINAL. SCHEDULE OF VALUES; (4) EXTRA CONSTRUCTION DOCUMENT SETS, (5) MARKED -UP SET OF (RECORD DOCUMENTS'": (6) EXTRA 'STOCK OF FINISH MATERIAL ITEMS; AND ('T) THE. PUNCH -LIST OF INCOMPLETE 'WORK ITEMS, PREPARED AT SUBSTANTIAL COMPLET M, INDICATING ACTUAL, COMPLETION DATES FOR EACH ITEM LISTED HEREIN. ROUGH CARPENTRY SECTION 011800 PROVIDE AND INSTALL BLOCKING, :BACKING, PLYWOOD. SHEATHING. FURRING .ANiD MISCELLANEOUS LIGHT FRAMING REQUIRED FAR COMPLETION OF THE WORK, WHICH 1S GENERALLY NOT EXPOSED; INHERE NOTED ON THE ORAWDINIGS, AND AS SPECIFIC HEREIN, PLYWOOD BLOCKING RPARTITIONS k MOUNTING PANELS FORMOUN TING EQUIPMENT. PROVIDE PLYWOOD APA C-D PLUGGED INT WITH EXTERIOR GLUE, MISC. WOW FRAMING & BLOCKING; CONSTRUCTION GRADE, #2 OR BETTER DOUGLAS FIR OR EQUAL, S4S, FIRE-RETAROANT TREATED UNLESS OTHERWISE INDICA ED.., MICRO -LAM LUMBER: BEAMS AND HEADERS. AS SCHEDULED. SEE DRAWING FOR DE'SICH STRESSES, FIRE -RETARDANT TREATED WOW PROVIDE FIRE --LABELED wOoD wITH MINIMUM FLAME SPREAD RATING OF 25 (UL FR-S), AT THE FOLLOWING LOCATION'S; (1) BLOCKING, CONCEALED WITHIN METAL FRAMED DRYWALL PARTITIONS IN NON-COMBUS118ILIE CIO NSIOUCTI # (2) FRAMWINO & BLOCKING LOCATED ABOVE FINISHED CEILINGS; AND (3) (BLOCKING WITHIN FIRE -RATED WALLS, PRESERVATIVE TREATMENT, PROVIDE PRESERVATIVE TREATED WOOD WWHERE INDICATED IN THE DRAWUINGS AND AS FOLLOWS: WOW CANTS, MAILERS, CURBS, BLOCKING. STRIPPING AND SIMILAR MEMBERS IN CONNECTION WITH ROOFING; AND WOOD WILLS SLEEPERS, BLOCKING. STRIPPINNO AND SIMILAR CONCEALED MEMBERS IN CONTACT' WITH MASONRY OR CONCRETE,. PRESERVATIVE TREATMENT SHALL BE WATER BORNE MATERIAL COMPLYING NTH( AWIP8 LP-2, KILN-ORIED W 109 MAAMLUM MOISTURE CONTENT FOR LUMBER AND 159 FOR PLYWOOD, INSTALLATION, SET ROUGH( CARPENTRY ACCURATELY TO RE!OUIRED LEVELS AND LINES. WITH MEMBERS PLUMB; AND TRUE AND ACCURATELY CUT AND FITTED. 'SECURELY ATTACH WORK TO SUBSTRATE, SHEATHINIM PLACE ROOF AND WALL SHEATHING WITH ENO JONTS,, STAGGERED, SECURE SHEETS OVER FIRM, BEARING MAINTAIN MINIMUM 1/16 INCH AND MAXIMUM I/$ INCHI SPADING BETLVEEN JOINTS. OF SHEETS ON WALLS, PLACE PERPENDICULAR TO FRAMING MEMBERS. FINISH CARPENTRY SECTION 01901) PROVIDE MISCELLANEOUS FINISH CARPENTRY ITEMS AS 'SHOWN ON THE DRAVWINOS. INSTALLATION, INSTALL WORK PLUMB. LEVEL. TRUE AND STRAIGHT NTH NO DISTORTION'S. 'SHIN AS REQUIRED USING CONCEALED SHIMS. SCRIBE AND CUT TO FIT ADJOINING WORK. (INSTALL WITH MINIMUM NUMBER OF JOINTS POSSIBLE, USING FULL-LENC7H PIECES TO THE GREATEST EXTENT POSSIBLE_ COPE, AT RETURNSS. MITER AT CORNERS. AND USE SCARF JOINTS. FOR END-TOENO JOINTS, TO, PROVIDE TIGHT FITTING JOINTS WITH FULL SuIRFAiCE CONTACT THROUGHOUT LENGTH OF JOINT. ANCHOR TO BLOCKING OR DIRECTLY TO SUBSTRATE WITH CO.fNTERSUNK,. CONCEALED FASTENERS AND FIND NAILING WHERE POSSIBLE ANCHOR COUNTERTOPS SECURELY TO SUPPORT SYSTEMS AS INDICATED. AT DRYWALL PARTITIONS. WHERE BLOCKING DOES NOT EMIT.. USE ADHESIVE AND PRE - DRILLED COUNTERSUNK TRIM -HEAD SHEET -METAL 'SCREWS TO ATTACH FINISH CARPENTRY TO METAL 'STUD& FILL RECESS TO MATCH SURFACE COLOR OF WOOD. SHOP ASSEMBLY: COMPLETELY ASSEMBLE COUNTERFRONT, CABINETS, COUNTERTOPS. POSTS. AND GLAZING IN SHOP PRIOR ICI. SHWMENT TO PROJECT SITE. MAKE INDIVIDUAL ITEMS IN 'SEQUE.NNCE, WTiH REMOVABLE MATERIALS 70 FACILITATE FIELD ASSEMBLY. FIELD INSTALLATIONN., INSTALL CASEWORK PLUMB, LEVEL, TRUE AND STRAICHIT WW1'11i NO DISTORTIONS. SHIM AS REQUIRED USING, CONCEALED SHAMES, INSTALL TO A TOLERANCE OF 1/8" IN 8"-0" FOR PLUMB ANO LEVEL AND WITH NO VARIATIONS IN. FLUSHNESS Or ADJOINING 'SURFACE'S, $CMBE AND OUT TO FIT ADJOINING WORK. ANCHOR TO BLOCKING OR DIRECTLY' TO SUBSTRATES WITH DISTORT OH 50 'THAT CABINET DONORS FIT OPENINGS PROPERLY AND ARE ACCURATELY ALIGNIED. ADJUST HARDWARE TO CENTER DOORS IN OPENINGS AND TO PROVIDE FREE ORATION. ANCHOR COUNTERTOP'S SECURELY TO BASE !UNITS AND OTHER SUPPORT SYSTEMS AS INDICATED. ANIUST AND CLEAN: REPAIR (DAMAGED AND DEFECTIVE CASEWORK WHERE POSSIBLE TO ELIMINATE DEFECTS, WERE NOT POSSIBLE TO REPAIR, REPLACE CASEWORK, CLEAN, LUBRICATE .AND ADJUST HARDWARE FOR SMOOTHS OPERATION. 1. ELONGATION CAPABILITY •- 25 PERCENT 2. SERVICE TEMPERATURE RANGE - 80 TO 400 DEGREES F (-62 TO 204 DEGREES C), S. SHARE A HARDNESS RANGE - 30 SILICONE SEALANT (TYPE J)r ASTM C' M TYPE S, NS, CLASS 25, 51NiLE COMPONENT, FUNGUS RESISTANT, CHEMICAL CURING, NON -SAGGING. NON-STANNINC, NON-BLEMNG TRANSLUCENT 'WHITE CENTER; SANITARY 17M MANUFACTURED BY GE SILICONES, 1, ELONGATION CAPABILITY - 25 PERCENT 2, SERVICE TEMPERATURE RANGE. - 80 TO 40D DEGREES F (-62 TO 2104 DEGREES C). S. SHARE A HARDNESS RANGE - 31 ACCESSORIES, PRIMMER, NON! -STAINING TYPE, REOOMMiENDED BY SEALANT MANUFA.MRER TO SUIT APPLICATION. JOINT' CLEANER: NCNI-CQRWLO9V+E AND NON -STAINING TYPE, RECOMMENDED BY SEALANT M1ANUFACTURER: COMPATIBLE W47I4 JOINT FORMING MATERIALS, JOINT BACKINNGt ASTMI D1056; ROUND, CLOSED CELL POLYETHLENIE FOAM ROD; CAIERSIZED 300,70 50 PERCENT LARGER THAN JOINT WIDTH, GREEN ROD MANUFACTURER TO SUIT APPLICATION. MIRK INCLUDES SURFACE PREPARATION AND PAINTTING OF INTERIOR AND EXTERIOR SURFACES FOR THE TOTAL PROJECT, WHERE ITEMS OR SURFACES; ARE NOT SPECIFICALLY MENTIONED. POINT THE SAME AS SIMILAR ADJACENT MATERIALS OR AREAS, EXPOSED PORTIONS OF FLUSH MOUNTED GRILLES, DIFFUSERS, AND RECESSED LIGHT FIXTURE TRIMS SHALL BE PAINTED TO MATCH THE COLCNR OF THE CEILING, IF THE CEILING IS PAINTED OTHER THAN WHITE, PAINTING NOT REQUIRED: UNLESS OTHERWISE iINDICATED. PAINTING; IS NOT REQUIRED ON CASEAORIK, PLASTIC LAMINATE, MECHANICAL EQUIPMENT, PLUMBING FINUTUIRES„ ELECTRICAL EQUIPMENT (EXCLUDING 'EXPOSED DISTRIBUTION CABINET(5) ELECTRICAL DEVICES. OR FOOD SERVICE EQUIPMENT, PAINTING IS NOT REQUIRED ON 'SURFACES SUCH AS WALLS OR COLINOS IN; CONCEALED OR INACCESSIBLE AREASL METAL SURFACES OF ANODIZED ALUMINUM, STAINLESS STEEL, CHROMIUM PLATE AND SIMILAR FINISHED MATERIALS DO NOT REQUIRE FINISH PAINTING, DO NOT PAINT OVER CODE-REQUIRFD LABELS OR EQUIPMENT IDENTIFICATION LABELS, JOB CONDITIONS: APPLY PAINTS ONLY MEN 'TEMPERATURE OF SURFACES TO BE PAINTED AND SURROUNDING AIR TEMPERATURES ARE WITHIN RECOMMENDED RANGE PERMITTED BY THE PAINT MANUFACTURER'S PRINTED INSTRUCTIONS. MATERIALSY PAINT AND STAIN MATERIALS AS LISTED IN THE FINISH IJEoEN1O- SURFACE PREPARATION: CLEAN SURFACES OF DIRT RUST, SCALE. (GREASE, MOISTURE. OR 'OTHER CONDITIONS OTHERWWSE DETRIMENTAL TO FORMATION OF A DURABLE PAINT FILM, PERFORM PREPARATION AND CLEANING PROCEDURES IN ACCORDANCE. WITH PAINT MANUFACTUNREWS PRINTED INSTRUCTIONS FOR EACH PARTICULAR SUBSTRATE CONDITION, REMOVE. HARIOWWARE. ACCESSORIES. PLATES, LIGHTING FIXTURES, AND SIMILAR ITEMS IN PLACE AND NOT TO BE FINISH 'PAINTED, OR PROVIDE PROTECTION PRIOR TO SURFACE PREPARATION AND PAINTING OPERATIONS. REMOVE. IF NECESSARY, FOR COMPLETE PAINTING OF ITEMS AND ADJACENT SURFACES. FOLLOWING COMPLETION OF !PAINT)NG OF EACH SPACE OR AREA. REINSTALL REMOVED ITEMS, COMPLY WITH MANUFACTURERS !PRINTED DIRECTIONS IN APPLYING PAINT MATERIALSS, USE APPLICATORS AND... 7ECHNINOI,NES BEST SUITED FOR SUBSTRATE AND TYPE OF MATERIAL BEING APPLIED. SCHEDULING: APPLY FIRST -COAT MATERIAL TO SURFACES. THAT HAVE BEEN. CLEANED, PRE-TREATED OR OTHERWISE PREPARED FOR PAINTING AS SOON AS PRACTICAL AFTER PREPARATION AND BEFORE. SUBSEQUENT SURFACE DETERIORATION, ALLOW SUFFICIENT TIME BETWEEN SUCCESSIVE COATINGS TO PERMIT PROPER DRYING. DD NOT RE -COAT UNTIL PAINT HAS DRIED TO MERE IT FEELS FIRM, DOES NOT DEFORM OR FEEL STICKY UNDER MODERATE THUMB PRESSURE, AND, APPLICATION OF ANOTTHFR COAT OF PAINT DOES NOT CAUSE LIFTING OR LOSS OF ADHESION OF THE UNDERCOAT'_ FORMULATE COLOR OF PRIME COAT' TO MATCH ,COLOR OF FINISH COATS - APPLY PAINT TO PROVIDE AN OPAQUE SMOOTH, SURFACE OF UNIFORM FINISH COLOR, .APPEARANCE AND COVERAGE, CLOUDINESS, SPOTTING, HOLIDAYS. LAP MARKS. BRUSH MARKS. RUNS,SAGS RAPIDNESS OR OTHEIR SURFACE IMPERFECIT{INS• WILL NOT BE ACCEPTABLE.. APPLY ADDITIONAL PAINT (COATS WHEN UNDERCOATS. STAINS OR OTHER COIN017IONS SHOW THROUGH FINAL COAT OF !PAINT, UNTIL PAINT FILM IS OF UNIFORM FINISH. COLOR AND APPEARANCE. GIVE SPECIAL ATTENTION TO INSURE THAT SURFACES, INCLUDING EDGES, CORNERS, CREVICES, AND EXPOSED FASTENERS RECEIVE A DRY FILM THICKNESS EQUIVALENT TO THAT OF FLAT SURFACES. REMOVE, REFINISH OR REPAINT' WORK NOT IN COMPLIANCE WITH SPECIFIED REQUIREMENTS. CLEAN UP: DURING THE PROGRESS OF THE WORK, REMOVE FROM SITE DISCARDED PAINT MATERIALS., RUBBISH, CANS AND RAGS AT END OF EACH WORK DAY. UPONCOMPLETION OF PAINTING WORK, CLEAN WINDOW GLASS AND OTHER DAMAGED PAINT -SPATTERED SURRFACE& REMOVE 'SPATTERED PAINT AND CLEAN [DAMAGED FINISH SURFACES, TOUCH-UP AND RESTORE ALL DAMAGED OR (DEFACED PAINTED 'SURFACES AFTER COMPLETION OF WORK OF OTHER TRADES, SCHEDULE •- SHOP PRIMED ITEMS FOR SITE FINISHING. PRE -FORMED METAL ROOFING (SECTION 07631): EXPOSED 'SURFACES OF METAL ROOFING, PANELS, MANUFACTURED ROOF SPECIALTIES (SECTION 07710), EXPOSED SURFACES OF METAL COPINGS AND TRIM, ALUMINUM DOORS N& FRAMES ('SECTION OSIII), INTERIOR AND EXTERIOR FACES OF STEEL DOORS AND FRAMES. SCHEDULE - EXTERIOR SURFACES WOOD - PAINTED, ONE COAT ALKYD PRIMMER SEALER. TWO COATS ALKYD ENAMEL. SURFACE AS 'SCHEDULED, STEEL UNPRIMED: ONE COAT .ZINC' CHROMATE PRIMER. TWO COATS ALKYO ENAMEL. GLOB O STEEL - SWOP PRIMED; TOUCH-UP 'WITH ZINC CHROMATE PRWER- TWO COATS ALKYD ENAMEL, GLOSS. STEEL - GALVANIZED: ONE COAT ZINC CHROMATE PRIMER, ONE COAT PRIMER SEALER :LATEX.. ONE COAT LATEX, FLAT WOOD - TRANSPARENT: AN SYSTEM: #3 AS SPECIFIED TIN CARPENTRY SECTIONS. WWASHCOAT, ONE COAT STAIN. FILLER COAT (FOR OPEN GRAINED WOOD ONLY), ONE COAT SEALER. TOP COAT, REFER TO MILLWORK DRAWINGS. WOOD - PAINTED= ONE COAT ALKYD PRIMER SEALER, TWO COATS ALKYD ENAMEL. SURFACE AS SCHEDULED. STEEL - UNPRIMED: ONE COAT ZINC CHROMATE PRIMER(. TWO COATS LATEX - !ENAMEL STAIN. STEEL - PRIMED! ONE COAT ZINC CHROMATE PRIMER. ONE COAT LATEX - ENAMEL, SATIN. STEEL - PRIMED: ONE OOAT ZINC CHROMATE PRIMER. ONE COAT ALKYD ENAMEL, MASSa STEEL •- CALVANIZED: ONE COAT ZINC CHWNNIATE (PRIMER'. ONE COAT' LATEX- ENAMEL. SATIN. 'PLASTER GYPSUM BOARD: ONE COAT LATEX PRIMER SEALER. TWO COATS (LATEX. SURFACE AS SCHEDULED, STRUCTURAL REFERENCE STRUCTURAL SHEET 'S-0 FOR MORE INFORMATION. A SPECIFICATIONS sFEri.o SCALE: NTS PRINTED March 5, 2021 h� wmarthur Rph, • gx A t R001207 u e R s Q� wp RED �AR�'N moo. ARCHITECT OF RECORD William F. Arthur AR-0012074 i Co pj U A, s � i Ln Q � = M (D M � X � LE Q O D E L) N (D O U N � M M O O O LL .IL cyv >� N N U N U o� � O U N O m Yp m N C .- -C C •+�—, U z C Q C -C U Lu �+ _ tea' _ m Q C Q w QO t w C:)P a CL N Z 5 0 N Z SPECIFICATIONS Grt �1 'EC 1.0 Go