Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCE 4-30-18�Z . J `_ -`.._ E Planning & Development Services Department RECEIVED Building & Code Regulations Division 23001Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 APR 3 0 2018 ST. Lucie County, Permitting Certification for Design Load Compliance Project Name: Hutchinson Island -Sprint M173XCO37 Project Address: 9560 S. Ocean Drive, Jensen Beach, FL 34957 Permit #: INSTRUCTIONS FOR USE: • This certification must be compy • Submit (2) copies for residential, o New Residences (single o Residential Addition o Any accessory structure o Any non-residential stru * Note: Form not required for intern certain minor building permits at the Occupancy Type: Construction d, signed, and sealed by the design professional of record. copies for commercial with all permit applications involving the following: multi -family) uiring a building permit r renovations provided that no exterior structural elements are affected and liscretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Builiding Code Fifth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one Enclosed Partially Enclosed X Open I 3. Risk Category: _I X II III IV Exposure Category: B C X D 4. Design Wind Velocity 127.1 mph X ASD LRFD End Zone Width: N/A ft 5. Mean Roof Height 176 ft Roof Pitch: N/A :12 Parapet: 6 ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: N/A Zone 2: N/A Zone 3: N/A Zone 4: N/A Zone 5: N/A Garage: N/A 7. Design Loads: Floor: NSA PSF Roof/Dead: NSA PSF Roof/Live: NSA Balcony: N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF i 8. Were Shear Walls Considered For Structure? Yes x Not Applicable Explain Why Not: Loading on appurtenance considered only 9. Is A Continuous Load Path Provided? Yes X Not Applicable Explain Why`Not: Loading on appurtenance considered only 10. Design Soil Bearing Pressure: NSA PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply witfil0a�p itfllleestructural portions of the building codes currently adopted and enforced by St. Lucie Count a ?r Y, at strG ral,elements depicted on these plans provide adequate resistance to the design forc�spX-if�*ed:ENSF '.• �� W_�v rJiang J. Yu 78286 Print Name Cert-# & Co. Cert Auth. 01FDewberry Engineers Inc. w • a 'gam ���.'0': 800 North Magnolia Ave. Suite 1000, Orlando, FL 32803 �E���r;N�►.�� Company Name & Address Revised 07/25/2014