Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 SCANNED BY FLORIDA ENERGY EFFIGIEN"bGI DE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: LANDERS RESIDENCE Builder Name: COASTAL CONSTRUCTION Street: g670 -4. OCEAN DRIVE Permit Office: ST. LUCIE COUNTY City, State, Zip: ST. LUCIE COUNTY, FL, Permit Number: Owner: GWENDOLYN LANDER Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (6065.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=20.0 5615.00 ftz b. Frame - Wood, Adjacent R=11.0 450.00 ftz 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 4 d. N/A R= ftz 10. Ceiling Types (2454.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=22.0 2454.00 ftz 6. Conditioned floor area above grade (ftz) 5313 b. N/A R= ftZ Conditioned floor area below grade (ftz) 0 c. N/A R= ftz 11. Ducts R ftz 7. Windows(916.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: A/C CLST. 6 425 a. U-Factor: Dbl, U=0.79 408.95 ft2 b. Sup: Attic, Ret: Attic, AH: A/C 6 325 SHGC: SHGC=0.28 b. U-Factor: Dbl, U=1.08 403.22 ftz 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 46.5 SEER:16.00 b. Central Unit 35.2 SEER:16.00 c. U-Factor: Dbl, U=0.66 88.00 ftz SHGC: SHGC=0.21 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 16.18 ftz a. Electric Strip Heat 34.0 COP:1.00 SHGC: other (see details) b. Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 7.918 ft. Area Weighted Average SHGC: 0.283 14. Hot water systems a. Electric Cap: 80 gallons 8. Floor Types (2458.0 sqft.) Insulation Area EF: 2.000 a. Slab -On -Grade Edge Insulation R=0.0 1347.00 ftz b. Conservation features b. Crawlspace R=19.0 1111.00 ftz None c. N/A R= ftz 15. Credits Pstat Total Proposed Mgdified Loads: 158.61 Glass/Floor Area: 0.172 PASS Total Bas line Loads: 171.68 1 hereby certify that the plans and specifications covered by Review of the plans and Sr'q?� this calculation are in compliance with the Florida Energy specifications covered by this O�Z$E Code. calculation indicates compliance �O with the Florida Energy Code. nnn:"'°%°:;• ��a '" PREP BY: DATE: I Before construction is completed this building will be inspected for r l a I compliance with Section 553.908 * n I hereby certify that this buildde 'gned, is in complianc Florida Statutes. y� with the Florida Energy Co I G'Ob W IE OWNER/AGENT: BUILDING OFFICIAL: DATE: A. DATE: i - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). Fli� Caay i 6/27/2018 1:05 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 8 -1 . FORM R406-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: LANDERS RESIDENCE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 5313 Lot # Owner Name: GWENDOLYN LANDER Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: COASTAL CONSTRUCTION Rotate Angle: 0 Street: OCEAN DRIVE Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House an: No City, State, Zip: ST. LUCIE COUNTY, Family Type: Single-family FL, New/Existing: New (From Plans) . Comment: CILIMATE V Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS i Number Name Area Volume 1 UNIT #1 3208 33795.8 2 UNIT #2 2105 21050 SPACES i Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 KITCHEN 329 3553.2 Yes 0 1 Yes Yes Yes 2 HALL. 44 440 No 0 1 Yes Yes Yes 3 POWDER 54 583.2 No 0 1 No Yes Yes 4 A/C CLST. 24 240 fro 0 1 No Yes Yes 5 OFFICE 261 2818.8 No 0 1 Yes Yes Yes 6 DINING 288 l 3398.4 0 1 Yes Yes Yes io 7 FOYER 348 4106.4 No 0 1 Yes Yes Yes 8 CLST.4 36 388.8 No 0 1 No Yes Yes 9 BATH 2 60 648 No 0 1 Yes Yes Yes 10 FAMILY ROOM 426 4600.8 No 0 1 Yes Yes Yes 11 BEDROOM #4 315 3402 No 0 1 1 Yes Yes Yes 12 STAIRS 81 761.4 No 0 1 Yes Yes Yes 13 CABANA 98 921.2 No 0 1 Yes Yes Yes 14 LOWER FOYER 844 7933.E No 4 1 Yes Yes Yes 15 LOFT. 316 3160 o 2 1 Yes Yes Yes 6 WIC 3 42 420 o 0 1 Yes Yes Yes 17 BEDROOM #3 180 1800 No 1 1 1 Yes Yes Yes 18 BATH 3 78 780 jVo 0 1 Yes Yes Yes y 19 STAIRWAY 160 1600 No 0 1 Yes Yes Yes 20 BATH 90 900 No 0 1 Yes Yes Yes 21 A/C 20 200 No b 1 No Yes Yes 6/27/2018 1:05 PM EnergyGauge® USA Slection R405.4.1 Compliant Software Page 2 of 8 FORM R405-2017 INPUT 5UMMAKY GtitGKL15 I KhVUK I SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 22 LOFT 162 1620 No 0 1 Yes Yes Yes 23 MASTER SUITE 356 3560 No 2 1 1 Yes Yes Yes 24 WIC 2 48 480 No 0 1 No Yes Yes 25 WIC 64 640 No 0 1 Yes Yes Yes 26 TLT 28 280 No l 0 1 Yes Yes Yes 27 MASTER BATH 267 2670 No 0 1 Yes Yes Yes _ 28 BEDROOM #2 210 2100 No 2 1 1 Yes Yes Yes 29 LAUNDRY 84 840 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio DINING 1.1 ft 0 22 ft2 ---- 0 1 0 2 Slab -On -Grade Edge Insulatio BATH 2 1 ft 0 6 ft2 ---- 0 1 0 3 Slab -On -Grade Edge Insulatio FAMILY ROOM 5.6 ft 0 57 ft2 ---- 0 1 0 4 Slab -On -Grade Edge Insulatio BEDROOM #4 4.7 ft 0 30 ft2 ---- 0 1 0 5 Slab -On -Grade Edge Insulatio STAIRS 7 ft 0 81 ft2 ---- 0 1 0 6 Slab -On -Grade Edge Insulatio CABANA 21 ft 0 98 ft2 ---- 0 1 0 7 Slab -On -Grade Edge Insulatio LOWER FOYER 37 ft 0 844 ft2 ---- 0 1 0 8 Crawlspace LOFT. 2.8 ft 0 60 ft2 19 0 0 1 9 Crawlspace WIC 3 10.8 ft 0 35 ft2 19 0 0 1 10Slab-On-Grade Edge Insulatio WIC 3 2.2 ft 0 7 ft2 ---- 0 1 0 11Crawlspace BEDROOM #3 21.8 0 180 ft2 19 0 0 1 12Crawlspace BATH 3 10.8 0 65 ft2 19 0 0 1 13SIab-On-Grade Edge Insulatio BATH 3 2.2 ft 0 13 ft2 ---- 0 1 0 14Slab-On-Grade Edge Insulatio STAIRWAY 1.5 0 31 ft2 ---- 0 1 0 15SIab-On-Grade Edge Insulatio BATH 14 ft 0 60 ft2 ---- 0 1 0 16Crawlspace LOFT 2.2 0 30 ft2 19 0 0 1 17Crawlspace MASTER SUITE 32.4 i 0 320 ft2 19 0 0 1 18SIab-On-Grade Edge Insulatio MASTER SUITE 3.6 ft 0 36 ft2 ---- 0 1 0 19Crawlspace WIC 2 1 ft 0 48 ft2 19 0 0 1 ~ 20Crawlspace WIC 6 0 0 48 ft2 19 0 0 1 21SIab-On-Grade Edge Insulatio WIC 2 i 0 16 ft2 ---- 0 1 0 6/27/2018 1:05 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS i # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 22Crawlspace TLT 9 ft 0 23 ft2 19 0 0 1 23SIab-On-Grade Edge Insulatio TLT 2 ft 0 5 ft2 ---- 0 1 0 24Crawlspace MASTER BATH 28.6 ft 0 218 ft2 19 0 0 1 25SIab-On-Grade Edge Insulatio MASTER BATH 5.4 ft 0 41 ft2 ---- 0 1 0 26Crawlspace LAUNDRY 1 ft 0 84 ft2 19 0 0 1 IROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area I Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 2585 ft2 I 0 ft2 Light 0.6 No 0.9 No 22 18.4 I ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented I 0 2453 ft2 N N CEILING # Ceiling Type Space ,R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) KITCHEN 22 Blown 324 ft2 0.1 Wood 2 Under Attic (Unvented) HALL. 22 Blown 44 ft2 0.1 Wood 3 Under Attic (Unvented) POWDER 22 Blown 54 ft2 0.1 Wood 4 Under Attic (Unvented) A/C CLST. 22 Blown 24 ft2 0.1 Wood 5 Under Attic (Unvented) OFFICE 22 Blown 261 ft2 0.1 Wood 6 Under Attic (Unvented) DINING 22 Blown 288 ft2 0.1 Wood 7 Under Attic (Unvented) FOYER 22 Blown 348 ft2 0.1 Wood 8 Under Attic (Unvented) CLST. 4 22 Blown 36 ft2 0.1 Wood 9 Under Attic (Unvented) BATH 2 22 Blown 60 ft2 0.1 Wood 10 Under Attic (Unvented) FAMILY ROOM 22 Blown 426 ft2 0.1 Wood 11 Under Attic (Unvented) BEDROOM #4 22 Blown 315 ft2 0.1 Wood 12 Under Attic (Unvented) CABANA 22 Blown 7 ft2 0.1 Wood 13 Under Attic (Unvented) LOWER FOYER 22 Blown 231 ft2 0.1 Wood 14 Under Attic (Unvented) LOFT 22 Blown 12 ft2 0.1 Wood 15 Under Attic (Unvented) TLT 22 Blown 12 ft2 0.1 Wood 16 Under Attic (Unvented) MASTER BATH 22 Blown 11 ft2 0.1 Wood 17 Under Attic (Unvented) BEDROOM #2 22 Blown 1 ft2 0.1 Wood 6/27/2018 1:05 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 8 17 REPORT / Adjacent „_ _ Cavity Width Height Sheathing Framing Solar Below 1 NE Exterior Concrete Block - Int InsulKITCHEN 20 18 0 10 10 195.0 ft2 0 0 0.5 2 SW Exterior Concrete Block - Int InsulKITCHEN 20 2 0 10 10 21.7 ft2 0 0 0.5 3 NW Exterior Concrete Block - Int InsulKITCHEN 20� 18 0 10 10 195.0 ft2 0 0 0.5 -4 NE Exterior Concrete Block - Int Insul HALL. 201 11 0 10 0 110.0 ft2 0 0 0.5 5 NE Exterior Concrete Block - Int Insul OFFICE 20 14 0 10 10 151.7 ft2 0 0 0.5 _ _ 6 SE Exterior Concrete Block - Int Insul OFFICE 20 18 0 10 10 195.0 ft2 0 0 0.5 _ 7 S Exterior Concrete Block - Int Insul OFFICE 20 4 3 10 10 46.0 ft2 0 0 0.5 _ 8 SW Exterior Concrete Block - Int Insul OFFICE I 20 7 0 10 10 75.8 ft2 0 0 0.5 _ 9 NW Exterior Concrete Block - Int Insul DINING I 20 18 0 11 10 213.0 ft2 0 0 0.5 10 SE Exterior Concrete Block - Int Insul FOYER I 2Q 13 0 11 10 153.8 ft2 0 0 0.5 11 SW Exterior Concrete Block - Int Insul BATH 2 20II 6 0 10 10 65.0 ft2 0 0 0.5 _ _ 12 SE Exterior Concrete Block - Int InsEAMILY ROO 20 1 0 10 10 10.8 ft2 0 0 0.5 _ 13 SW Exterior Concrete Block - Int InsEAMILY ROO I 20 20 0 10 10 216.7 ft2 0 0 0.5 14 NW Exterior Concrete Block - Int InsEAMILY ROO 4 21 0 10 10 227.5 ft2 0 0 0.5 _ 15 NE Exterior Concrete Block - Int InsBEDROOM # 20 10 0 10 10 108.3 ft2 0 0 0.5 _ 16 SE Exterior Concrete Block - Int InsBEDROOM # I 20 23 0 10 10 249.2 ft2 0 0 0.5 _ 17 SW Exterior Concrete Block - Int InsBEDROOM # I 20 15 0 10 10 162.5 ft2 0 0 0.5 18 NW Exterior Concrete Block - Int InsBEDROOM # 21 1 0 10 10 10.8 ft2 0 0 0.5 _ 19 NE Exterior Concrete Block - Int Insul STAIRS 2I0 5 0 9 5 47.1 ft2 0 0 0.5 20 SE Exterior Concrete Block - Int Insul STAIRS. 20 1 0 9 5 9.4 ft2 0 0 0.5 21 NW Exterior Concrete Block - Int Insul STAIRS 2I0 1 0 9 5 9.4 ft2 0 0 0.5 _22 NE Exterior Concrete Block - Int Insul CABANA 2I0 14 0 9 5 131.8 ft2 0 0 0.5 _23 NW Exterior Concrete Block - Int Insul CABANA 20 7 0 9 5 65.9 ft2 0 0 0.5 _24 NE Exterior Concrete Block - Int InsLDWER FOY 20 14 0 9 5 131.8 ft2 0 0 0.5 _25 NW Exterior Concrete Block - Int InsUDWER FOY 20 23 0 9 5 216.6 ft2 0 0 0.5 _26 NW Exterior Concrete Block - Int Insul LOFT. 20 15 0 10 0 150.0 ft2 01 0 0.5 _27 NE Exterior Concrete Block - Int Insul WIC 3 20 7 0 10 0 70.0 ft2 0 0 0.5 _28 SE Exterior Concrete Block - Int Insul WIC 3 20 6 0 10 0 60.0 ft2 0 0 0.5 _29 SE Exterior Concrete Block - Int Insl3EDRO01V1 IF 20 12 0 10 0 120.0 ft2 0 0 0.5 _ 30 S Exterior Concrete Block - Int InsBEDROOM IF 20 2 10 10 0 28.3 ft2 0 0 0.5 _31 SW Exterior Concrete Block - Int InsBEDROOM # 20 7 0 10 0 70.0 ft2 0 0 0.5 _32 NE Exterior Concrete Block - Int Insul BATH 3 20 13 0 10 0 130.0 ft2 0 0 0.5 _33 NE Exterior Concrete Block - Int InstSTAIRVNAY 20 8 0 10 0 80.0 ft2 0 0 0.5 _34 NE Exterior Concrete Block- Int Insul BATH 20 15 0 10 0 150.0 ft2 0 0 0.5 _35 NW Exterior Concrete Block - Int Insul BATH 20 6 0 10 0 60.0 ft2 0 0 0.5 36 SE Exterior Concrete Block - Int Insul LOFT I 20 12 0 10 0 120.0 ft2 0 0 0.5 _37 SW Exterior Concrete Block - Int InsMASTER SUI 20 18 0 10 0 180.0 ft2 0 0 0.5 38 NW Exterior Concrete Block - Int InsMASTER SUI 20 18 0 10 0 180.0 ft2 0 0 0.5 _39 SW Exterior Concrete Block - Int Insul WIC 20 8 0 10 0 80.0 ft2 0 0 0.5 40 NE Exterior Concrete Block - Int Insul TILT 20 6 0 10 0 60.0 ft2 0 0 0.5 r _41 SE Exterior Concrete Block - Int Insul TLT 20 5 0 10 0 50.0 ft2 0 0 0.5 _42 NE Exterior Concrete Block - Int InsMASTER BA 20 3 0 10 0 30.0 ft2 0 0 0.5 _43 SE Exterior Concrete Block - Int InsMASTER BA 20 18 0 10 0 180.0 ft2 0 0 0.5 6/27/2018 1:05 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 8 PoRM Rdf15-9f117 INPl1T Sl1MMARY CHECKI IST REPORT WALLS Adjacent Cav ty Width Height Sheathing Framing Solar Below SpaceR-1/able ue Et n Et n Area 44 SW Exterior Concrete Block - Int Ins811ASTER BA 20 14 0 10 0 140.0 ft2 0 0 0.5 0 45 SW Exterior Concrete Block - Int InsBIEDROOM # 20I 3 0 10 0 30.0 ft2 0 0 0.5 0 46 NW Exterior I Concrete Block - Int InsBEDROOM # 20 16 0 10 0 160.0 ft2 0 0 0.8 0 47 S Exterior I Concrete Block - Int InsIJDWER FOY 20 50 9 4 466.7 ft2 0 0.5 0 48 N Garage Frame - Wood FOYER I 11 45 10 450.0 ft2 0 0.023 0.6 0 - WINDOWS Orientation shown is the entered, Proposed orientation. V Wall I Overhang # Ornt ID Frame Panes NFRC U-Faetor SHGC Imp Area Depth Separation Int Shade Screening 1 NE 1 Vinyl Low-E Double Yes 1.08 0.3 N 27.6 ft2 2 ft 0 in 1 ft 4 in None None 2 NW 3 Vinyl Low-E Double Yes 0.79 0.28 N 27.0 ft2 20 ft 0 in 1 ft 4 in None None 3 NW 3 Vinyl Low-E Double Yes 1.08 0.3 N 27.6 ft2 20 ft 0 in 1 ft 4 in None None 4 NE 5 Vinyl Low-E Double Yes 0.79 0.28 N 27.2 ft2 2 ft 0 in 1 ft 4 in None None 5 SE 6 Vinyl Low-E Double Yes 0.7I9 0.28 N 27.2 ft2 2 ft 0 in 1 ft 4 in None None 6 NW 9 Vinyl Low-E Double Yes 1.0I8 0.3 N 144.0 ft2 10 ft 0 in 1 ft 4 in None None 7 SW 11 Vinyl Low-E Double Yes 0.JI 0.31 N 9.3 ft2 2 ft 0 in 1 ft 4 in None None 8 SW 13 Vinyl Low-E Double Yes 0.79 0.28 N 27.2 ft2 2 ft 0 in 1 ft 4 in None None 9 NW 14 Vinyl Low-E Double Yes 1.08 0.3 N 108.0 ft2 10 ft 0 in 1 ft 4 in None None 10 SE 16 Vinyl Low-E Double Yes 0.79 0.28 N 27.1 ft2 2 ft 0 in 1 ft 4 in None None 11 SW 17 Vinyl Low-E Double Yes 0.79 0.28 N 27.1 ft2 2 ft 0 in 1 ft 4 in None None 12 NW 23 Vinyl Low-E Double Yes 0.79 0.28 N 9.3 ft2 20 ft 0 in 1 ft 4 in None None 13 NW 25 Vinyl Low-E Double Yes 0.79 0.28 N 24.0 ft2 20 ft 0 in 1 ft 4 in None None 14 NW 26 Vinyl Low-E Double Yes 1.08 0.3 N 96.0 ft2 10 ft 0 in 1 ft 4 in None None 15 SE 29 Vinyl Low-E Double Yes 0.79 0.28 N 40.0 ft2 2 ft 0 in 1 ft 4 in None None 16 NE 32 Vinyl Low-E Double Yes 0.II81 0.31 N 6.8 ft2 2 ft 0 in 1 ft 4 in None None 17 NE 33 Vinyl Low-E Double Yes O.II 9 0.28 N 11.7 ft2 2 ft 0 in 1 ft 4 in None None 18 NE 34 Vinyl Low-E Double Yes 0!79 0.28 N 6.8 ft2 2 ft 0 in 1 ft 4 in None None 19 SE 36 Vinyl Low-E Double Yes 0166 0.21 N 48.0 ft2 8 ft 0 in 1 ft 4 in None None 20 SW 37 Vinyl Low-E Double Yes 0179 0.28 N 23.4 ft2 2 ft 0 in 1 ft 4 in None None 21 NW 38 Vinyl Low-E Double Yes 0.79 0.28 N 96.0 ft2 10 ft 0 in 1 ft 4 in None None 22 SE 43 Vinyl Low-E Double Yes 0166 0.21 N 40.0 ft2 2 ft 0 in 1 ft 4 in None None 23 SW 44 Vinyl Low-E Double Yes OI79 0.28 N 20.0 ft2 2 ft 0 in 1 ft 4 in None None 24 S 47 Vinyl Low-E Double Yes OI 79 0.28 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None (GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 800 ft2 800 ft2 I 50 ft 9.4 ft 11 6/27/2018 1:05 PM EnergyGauge® USA ISection R405.4.1 Compliant Software Page 6 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILI TRATION i # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000459 6398.7 351.28 660.63 .3591 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 2 Electric Strip Heat/ Electric Strip Heat/ None None COP:1 34 kBtu/hr COP:1 27 kBtu/hr 1 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype I Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit/ Central Unit/ Split Split SEER: 16 46.5 kBtu/hr cfm 0.7 SEER: 16 35.2 kBtu/hr cfm 0.7 1 2 sys#1 sys#2 HOT WATER SYSTEM i # System Type SubType Location EF I Cap Use SetPnt Conservation 1 Electric Heat Pump Garage 2 I 80 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name System Collector Storage Model # Collector Model # Area Volume FEF None None I ft2 DUCTS V # ---- Supply -- Location R-Value Area ---- Return ---- Location Area Air CFM 25 CFM25 Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 2 Attic 6 425 ft2 Attic 6 325 ft2 Attic Attic 105 ft2l 75 ft2 Default Leakage A/C CLST. (Default) (Default) Default Leakage A/C (Default) (Default) 1 1 2 2 TEMPERATURES i Programable Thermostat: Y CoolingJan Feb Mar HeatinJan Feb X Mar Ventin Jan Feb X Mar Ceiling Faris: A r May f Apr f j May [X A r [ Ma X Jun X Jul rj Au �Xj Se [ ] Oct 4 Jun 4 Jul AuSep [ ] Oct [ Jun [ Jul Aug Se [X] Oct [ ] Nov []Nov [X] Nov [ j Dec [X] Dec j ] Dec 6/27/2018 1:05 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 7 of 8 FORM R405-2017 INPUT SUMMARY C ECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 I 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Beating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area (Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL. Default(8 Ibs/sq.ft. ft2 ft 0.3 POWDER Default(8 Ibs/sq.ft. ft2 ft 0.3 A/C CLST. Default(8 Ibs/sq.ft. ft2 ft 0.3 OFFICE Default(8 Ibs/sq.ft. ft2 ft 0.3 DINING Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST. 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 FAMILY ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM #4 Default(8 Ibs/sq.ft. ft2 ft 0.3 STAIRS Default(8 Ibs/sq.ft. ft2 ft 0.3 CABANA Default(8 Ibs/sq.ft. ft2 ft 0.3 LOWER FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 LOFT. Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM #3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 STAIRWAY Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 A/C Default(8 Ibs/sq.ft. ft2 ft 0.3 LOFT Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER SUITE Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 TLT Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM #2 Default(8 Ibs/s .ft. ft2 ft 0.3 LAUNDRY Name: Test Rater Rating Compant: Test Rater Date: 6/27/2018 1:05 PM EnergyGauge® USAI Section R405.4.1 Compliant Software Page 8 of 8 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: LANDERS RESIDENCE Builder Name: COASTAL CONSTRUCTION Street: OCEAN DRIVE Permit Office: ST. LUCIE COUNTY City, State, Zip: ST. LUCIE COUNTY, FL, Permit Number: Y U Owner: GWENDOLYN LANDER Jurisdiction: ST. LUCIE COUNTY w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in they building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with Ceiling/attic i the insulation and any gaps in the air barrier shall be sealed. /soffit The insulation in an dropped ceiling/soffit y pp g shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and fralming, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. I Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shal` be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts exterior or unconditioned space shall be sealed. opening to Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the gauge and conditioned spac Ds. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. I_ thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building envelope shall ithermal be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by, the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and_WgIls or ceffilonas, a. in addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 6/27/2018 1:06 PM EnergyGaugeO USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE ESTIMATED ENERGY The lower the Energy Performa EVEL (EPL) DISPLAY CARD :RFORMANCE INDEX* = 92 Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 81.7 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 5313 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a b) Solar Heat Gain Coefficient (SHGC) 7b c) Area 7c 8. Skylights a) U-factor:(weighted average) b) Solar Heat Gain Coefficient (SHGC) 9. Floor type, insulation level: 14. Heating system: Capacity 61.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 19.b 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 2.00 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 20.b f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 22.0 b) Cross ventilation No b) Single assembly 11 b. I c) Whole house fan No c) Knee walls/skylight walls 11 c. I d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit 1 f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with tfie Florida Building Code, Energy Conservation, through the above energy saving features which will be in led (or, exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed ed o installed code compliant features. Builder Signatu y,S_7v Address of New Home - Date: 7116Zg City/FL Zip: ST. LUCIE COUNTY, FL 6/27/2018 1:06:19 PM EnergyGauge® USA 6.0.02 - �IaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1