HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 SCANNED
BY
FLORIDA ENERGY EFFIGIEN"bGI DE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: LANDERS RESIDENCE
Builder Name: COASTAL CONSTRUCTION
Street: g670 -4. OCEAN DRIVE
Permit Office: ST. LUCIE COUNTY
City, State, Zip: ST. LUCIE COUNTY, FL,
Permit Number:
Owner: GWENDOLYN LANDER
Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (6065.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=20.0 5615.00 ftz
b. Frame - Wood, Adjacent
R=11.0 450.00 ftz
3. Number of units, if multiple family 1
c. N/A
R= ftz
4. Number of Bedrooms 4
d. N/A
R= ftz
10. Ceiling Types (2454.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=22.0 2454.00 ftz
6. Conditioned floor area above grade (ftz) 5313
b. N/A
R= ftZ
Conditioned floor area below grade (ftz) 0
c. N/A
R= ftz
11. Ducts
R ftz
7. Windows(916.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: A/C CLST.
6 425
a. U-Factor: Dbl, U=0.79 408.95 ft2
b. Sup: Attic, Ret: Attic, AH: A/C
6 325
SHGC: SHGC=0.28
b. U-Factor: Dbl, U=1.08 403.22 ftz
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.30
a. Central Unit
46.5 SEER:16.00
b. Central Unit
35.2 SEER:16.00
c. U-Factor: Dbl, U=0.66 88.00 ftz
SHGC: SHGC=0.21
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 16.18 ftz
a. Electric Strip Heat
34.0 COP:1.00
SHGC: other (see details)
b. Electric Strip Heat
27.0 COP:1.00
Area Weighted Average Overhang Depth: 7.918 ft.
Area Weighted Average SHGC: 0.283
14. Hot water systems
a. Electric
Cap: 80 gallons
8. Floor Types (2458.0 sqft.) Insulation Area
EF: 2.000
a. Slab -On -Grade Edge Insulation R=0.0 1347.00 ftz
b. Conservation features
b. Crawlspace R=19.0 1111.00 ftz
None
c. N/A R= ftz
15. Credits
Pstat
Total Proposed Mgdified Loads: 158.61
Glass/Floor Area: 0.172
PASS
Total Bas
line Loads: 171.68
1 hereby certify that the plans and specifications covered by
Review of the plans and
Sr'q?�
this calculation are in compliance with the Florida Energy
specifications covered by this
O�Z$E
Code.
calculation indicates compliance
�O
with the Florida Energy Code.
nnn:"'°%°:;• ��a
'"
PREP BY:
DATE: I
Before construction is completed
this building will be inspected for
r
l a
I
compliance with Section 553.908
* n
I hereby certify that this buildde 'gned, is in complianc
Florida Statutes.
y�
with the Florida Energy Co I
G'Ob W IE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE: A.
DATE:
i
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
Fli� Caay
i
6/27/2018 1:05 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 8
-1 .
FORM R406-2017 INPUT SUMMARY CHECKLIST
REPORT
PROJECT
Title:
LANDERS RESIDENCE
Bedrooms:
4
Address Type:
Street Address
Building Type:
User
Conditioned Area:
5313
Lot #
Owner Name:
GWENDOLYN LANDER
Total Stories:
1
Block/Subdivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
COASTAL CONSTRUCTION
Rotate Angle:
0
Street:
OCEAN DRIVE
Permit Office:
ST. LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
ST. LUCIE COUNTY
Whole House
an: No
City, State,
Zip:
ST. LUCIE COUNTY,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
. Comment:
CILIMATE
V
Design Temp
Int Design Temp
Heating
Design Daily Temp
Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree
Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
i
Number
Name
Area
Volume
1
UNIT #1
3208
33795.8
2
UNIT #2
2105
21050
SPACES
i
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
KITCHEN
329
3553.2 Yes
0
1
Yes
Yes
Yes
2
HALL.
44
440 No
0
1
Yes
Yes
Yes
3
POWDER
54
583.2 No
0
1
No
Yes
Yes
4
A/C CLST.
24
240 fro
0
1
No
Yes
Yes
5
OFFICE
261
2818.8 No
0
1
Yes
Yes
Yes
6
DINING
288
l
3398.4
0
1
Yes
Yes
Yes
io
7
FOYER
348
4106.4 No
0
1
Yes
Yes
Yes
8
CLST.4
36
388.8 No
0
1
No
Yes
Yes
9
BATH 2
60
648 No
0
1
Yes
Yes
Yes
10
FAMILY ROOM
426
4600.8 No
0
1
Yes
Yes
Yes
11
BEDROOM #4
315
3402 No
0
1
1
Yes
Yes
Yes
12
STAIRS
81
761.4 No
0
1
Yes
Yes
Yes
13
CABANA
98
921.2 No
0
1
Yes
Yes
Yes
14
LOWER FOYER
844
7933.E No
4
1
Yes
Yes
Yes
15
LOFT.
316
3160 o
2
1
Yes
Yes
Yes
6
WIC 3
42
420 o
0
1
Yes
Yes
Yes
17
BEDROOM #3
180
1800 No
1
1
1
Yes
Yes
Yes
18
BATH 3
78
780 jVo
0
1
Yes
Yes
Yes
y
19
STAIRWAY
160
1600 No
0
1
Yes
Yes
Yes
20
BATH
90
900 No
0
1
Yes
Yes
Yes
21
A/C
20
200 No
b
1
No
Yes
Yes
6/27/2018 1:05 PM EnergyGauge® USA Slection R405.4.1 Compliant Software Page 2 of 8
FORM R405-2017 INPUT 5UMMAKY GtitGKL15 I KhVUK I
SPACES
Number Name Area Volume
Kitchen Occupants
Bedrooms
InfilID
Finished
Cooled
Heated
22
LOFT 162 1620
No
0
1
Yes
Yes
Yes
23
MASTER SUITE 356 3560
No
2
1
1
Yes
Yes
Yes
24
WIC 2 48 480
No
0
1
No
Yes
Yes
25
WIC 64 640
No
0
1
Yes
Yes
Yes
26
TLT 28 280
No l
0
1
Yes
Yes
Yes
27
MASTER BATH 267 2670
No
0
1
Yes
Yes
Yes
_
28
BEDROOM #2 210 2100
No
2
1
1
Yes
Yes
Yes
29
LAUNDRY 84 840
No
0
1
No
Yes
Yes
FLOORS
# Floor Type Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulatio DINING
1.1 ft
0
22 ft2
----
0
1
0
2 Slab -On -Grade Edge Insulatio BATH 2
1 ft
0
6 ft2
----
0
1
0
3 Slab -On -Grade Edge Insulatio FAMILY ROOM
5.6 ft
0
57 ft2
----
0
1
0
4 Slab -On -Grade Edge Insulatio BEDROOM #4
4.7 ft
0
30 ft2
----
0
1
0
5 Slab -On -Grade Edge Insulatio STAIRS
7 ft
0
81 ft2
----
0
1
0
6 Slab -On -Grade Edge Insulatio CABANA
21 ft
0
98 ft2
----
0
1
0
7 Slab -On -Grade Edge Insulatio LOWER FOYER
37 ft
0
844 ft2
----
0
1
0
8 Crawlspace LOFT.
2.8 ft
0
60 ft2
19
0
0
1
9 Crawlspace WIC 3
10.8 ft
0
35 ft2
19
0
0
1
10Slab-On-Grade Edge Insulatio WIC 3
2.2 ft
0
7 ft2
----
0
1
0
11Crawlspace BEDROOM #3
21.8
0
180 ft2
19
0
0
1
12Crawlspace BATH 3
10.8
0
65 ft2
19
0
0
1
13SIab-On-Grade Edge Insulatio BATH 3
2.2 ft
0
13 ft2
----
0
1
0
14Slab-On-Grade Edge Insulatio STAIRWAY
1.5
0
31 ft2
----
0
1
0
15SIab-On-Grade Edge Insulatio BATH
14 ft
0
60 ft2
----
0
1
0
16Crawlspace LOFT
2.2
0
30 ft2
19
0
0
1
17Crawlspace MASTER SUITE
32.4 i
0
320 ft2
19
0
0
1
18SIab-On-Grade Edge Insulatio MASTER SUITE
3.6 ft
0
36 ft2
----
0
1
0
19Crawlspace WIC 2
1 ft
0
48 ft2
19
0
0
1
~
20Crawlspace WIC
6 0
0
48 ft2
19
0
0
1
21SIab-On-Grade Edge Insulatio WIC
2 i
0
16 ft2
----
0
1
0
6/27/2018 1:05 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
i
#
Floor Type
Space Perimeter
Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
22Crawlspace
TLT 9 ft
0
23 ft2
19
0
0 1
23SIab-On-Grade Edge Insulatio
TLT 2 ft
0
5 ft2
----
0
1 0
24Crawlspace
MASTER BATH 28.6 ft
0
218 ft2
19
0
0 1
25SIab-On-Grade
Edge Insulatio
MASTER BATH 5.4 ft
0
41 ft2
----
0
1 0
26Crawlspace
LAUNDRY 1 ft
0
84 ft2
19
0
0 1
IROOF
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck Pitch
V #
Type Materials Area
I
Area
Color
Absor.
Tested
Tested
Insul. (deg)
1
Hip
Metal 2585 ft2 I
0 ft2
Light
0.6
No
0.9
No
22 18.4
I
ATTIC
V #
Type
Ventilation Vent
Ratio (1 in)
Area
RBS
IRCC
1
Full attic
Unvented I
0
2453 ft2
N
N
CEILING
#
Ceiling Type
Space
,R-Value
Ins Type
Area Framing Frac Truss Type
1
Under Attic (Unvented)
KITCHEN
22
Blown
324 ft2
0.1
Wood
2
Under Attic (Unvented)
HALL.
22
Blown
44 ft2
0.1
Wood
3
Under Attic (Unvented)
POWDER
22
Blown
54 ft2
0.1
Wood
4
Under Attic (Unvented)
A/C CLST.
22
Blown
24 ft2
0.1
Wood
5
Under Attic (Unvented)
OFFICE
22
Blown
261 ft2
0.1
Wood
6
Under Attic (Unvented)
DINING
22
Blown
288 ft2
0.1
Wood
7
Under Attic (Unvented)
FOYER
22
Blown
348 ft2
0.1
Wood
8
Under Attic (Unvented)
CLST. 4
22
Blown
36 ft2
0.1
Wood
9
Under Attic (Unvented)
BATH 2
22
Blown
60 ft2
0.1
Wood
10
Under Attic (Unvented)
FAMILY ROOM
22
Blown
426 ft2
0.1
Wood
11
Under Attic (Unvented)
BEDROOM #4
22
Blown
315 ft2
0.1
Wood
12
Under Attic (Unvented)
CABANA
22
Blown
7 ft2
0.1
Wood
13
Under Attic (Unvented)
LOWER FOYER
22
Blown
231 ft2
0.1
Wood
14
Under Attic (Unvented)
LOFT
22
Blown
12 ft2
0.1
Wood
15
Under Attic (Unvented)
TLT
22
Blown
12 ft2
0.1
Wood
16
Under Attic (Unvented)
MASTER BATH
22
Blown
11 ft2
0.1
Wood
17
Under Attic (Unvented)
BEDROOM #2
22
Blown
1 ft2
0.1
Wood
6/27/2018 1:05 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 8
17
REPORT
/ Adjacent „_ _ Cavity Width Height Sheathing Framing Solar Below
1
NE
Exterior
Concrete Block - Int InsulKITCHEN
20
18
0
10
10
195.0 ft2
0
0
0.5
2
SW
Exterior
Concrete Block - Int InsulKITCHEN
20
2
0
10
10
21.7 ft2
0
0
0.5
3
NW
Exterior
Concrete Block - Int InsulKITCHEN
20�
18
0
10
10
195.0 ft2
0
0
0.5
-4
NE
Exterior
Concrete Block - Int Insul HALL.
201
11
0
10
0
110.0 ft2
0
0
0.5
5
NE
Exterior
Concrete Block - Int Insul OFFICE
20
14
0
10
10
151.7 ft2
0
0
0.5
_
_ 6
SE
Exterior
Concrete Block - Int Insul OFFICE
20
18
0
10
10
195.0 ft2
0
0
0.5
_ 7
S
Exterior
Concrete Block - Int Insul OFFICE
20
4
3
10
10
46.0 ft2
0
0
0.5
_ 8
SW
Exterior
Concrete Block - Int Insul OFFICE
I
20
7
0
10
10
75.8 ft2
0
0
0.5
_ 9
NW
Exterior
Concrete Block - Int Insul DINING
I
20
18
0
11
10
213.0 ft2
0
0
0.5
10
SE
Exterior
Concrete Block - Int Insul FOYER
I
2Q
13
0
11
10
153.8 ft2
0
0
0.5
11
SW
Exterior
Concrete Block - Int Insul BATH 2
20II
6
0
10
10
65.0 ft2
0
0
0.5
_
_ 12
SE
Exterior
Concrete Block - Int InsEAMILY ROO
20
1
0
10
10
10.8 ft2
0
0
0.5
_ 13
SW
Exterior
Concrete Block - Int InsEAMILY ROO
I
20
20
0
10
10
216.7 ft2
0
0
0.5
14
NW
Exterior
Concrete Block - Int InsEAMILY ROO
4
21
0
10
10
227.5 ft2
0
0
0.5
_ 15
NE
Exterior
Concrete Block - Int InsBEDROOM #
20
10
0
10
10
108.3 ft2
0
0
0.5
_ 16
SE
Exterior
Concrete Block - Int InsBEDROOM #
I
20
23
0
10
10
249.2 ft2
0
0
0.5
_ 17
SW
Exterior
Concrete Block - Int InsBEDROOM #
I
20
15
0
10
10
162.5 ft2
0
0
0.5
18
NW
Exterior
Concrete Block - Int InsBEDROOM #
21
1
0
10
10
10.8 ft2
0
0
0.5
_ 19
NE
Exterior
Concrete Block - Int Insul STAIRS
2I0
5
0
9
5
47.1 ft2
0
0
0.5
20
SE
Exterior
Concrete Block - Int Insul STAIRS.
20
1
0
9
5
9.4 ft2
0
0
0.5
21
NW
Exterior
Concrete Block - Int Insul STAIRS
2I0
1
0
9
5
9.4 ft2
0
0
0.5
_22
NE
Exterior
Concrete Block - Int Insul CABANA
2I0
14
0
9
5
131.8 ft2
0
0
0.5
_23
NW
Exterior
Concrete Block - Int Insul CABANA
20
7
0
9
5
65.9 ft2
0
0
0.5
_24
NE
Exterior
Concrete Block - Int InsLDWER FOY
20
14
0
9
5
131.8 ft2
0
0
0.5
_25
NW
Exterior
Concrete Block - Int InsUDWER FOY
20
23
0
9
5
216.6 ft2
0
0
0.5
_26
NW
Exterior
Concrete Block - Int Insul LOFT.
20
15
0
10
0
150.0 ft2
01
0
0.5
_27
NE
Exterior
Concrete Block - Int Insul WIC 3
20
7
0
10
0
70.0 ft2
0
0
0.5
_28
SE
Exterior
Concrete Block - Int Insul WIC 3
20
6
0
10
0
60.0 ft2
0
0
0.5
_29
SE
Exterior
Concrete Block - Int Insl3EDRO01V1 IF
20
12
0
10
0
120.0 ft2
0
0
0.5
_ 30
S
Exterior
Concrete Block - Int InsBEDROOM IF
20
2
10
10
0
28.3 ft2
0
0
0.5
_31
SW
Exterior
Concrete Block - Int InsBEDROOM #
20
7
0
10
0
70.0 ft2
0
0
0.5
_32
NE
Exterior
Concrete Block - Int Insul BATH 3
20
13
0
10
0
130.0 ft2
0
0
0.5
_33
NE
Exterior
Concrete Block - Int InstSTAIRVNAY
20
8
0
10
0
80.0 ft2
0
0
0.5
_34
NE
Exterior
Concrete Block- Int Insul BATH
20
15
0
10
0
150.0 ft2
0
0
0.5
_35
NW
Exterior
Concrete Block - Int Insul BATH
20
6
0
10
0
60.0 ft2
0
0
0.5
36
SE
Exterior
Concrete Block - Int Insul LOFT
I
20
12
0
10
0
120.0 ft2
0
0
0.5
_37
SW
Exterior
Concrete Block - Int InsMASTER SUI
20
18
0
10
0
180.0 ft2
0
0
0.5
38
NW
Exterior
Concrete Block - Int InsMASTER SUI
20
18
0
10
0
180.0 ft2
0
0
0.5
_39
SW
Exterior
Concrete Block - Int Insul WIC
20
8
0
10
0
80.0 ft2
0
0
0.5
40
NE
Exterior
Concrete Block - Int Insul TILT
20
6
0
10
0
60.0 ft2
0
0
0.5
r
_41
SE
Exterior
Concrete Block - Int Insul TLT
20
5
0
10
0
50.0 ft2
0
0
0.5
_42
NE
Exterior
Concrete Block - Int InsMASTER BA
20
3
0
10
0
30.0 ft2
0
0
0.5
_43
SE
Exterior
Concrete Block - Int InsMASTER BA
20
18
0
10
0
180.0 ft2
0
0
0.5
6/27/2018 1:05 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 8
PoRM Rdf15-9f117
INPl1T Sl1MMARY CHECKI
IST REPORT
WALLS
Adjacent
Cav ty Width
Height
Sheathing Framing Solar
Below
SpaceR-1/able
ue Et
n
Et n
Area
44
SW
Exterior
Concrete Block - Int Ins811ASTER BA 20 14
0
10 0
140.0 ft2
0
0
0.5
0
45
SW
Exterior
Concrete Block - Int InsBIEDROOM # 20I 3
0
10 0
30.0 ft2
0
0
0.5
0
46
NW
Exterior
I
Concrete Block - Int InsBEDROOM # 20 16
0
10 0
160.0 ft2
0
0
0.8
0
47
S
Exterior
I
Concrete Block - Int InsIJDWER FOY 20 50
9 4
466.7 ft2
0
0.5
0
48
N
Garage
Frame - Wood
FOYER
I
11 45
10
450.0 ft2
0
0.023
0.6
0
-
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
I
Overhang
#
Ornt
ID
Frame
Panes
NFRC
U-Faetor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
NE
1
Vinyl
Low-E Double
Yes
1.08 0.3
N
27.6 ft2
2 ft 0 in
1 ft 4 in
None
None
2
NW
3
Vinyl
Low-E Double
Yes
0.79 0.28
N
27.0 ft2
20 ft 0 in
1 ft 4 in
None
None
3
NW
3
Vinyl
Low-E Double
Yes
1.08 0.3
N
27.6 ft2
20 ft 0 in
1 ft 4 in
None
None
4
NE
5
Vinyl
Low-E Double
Yes
0.79 0.28
N
27.2 ft2
2 ft 0 in
1 ft 4 in
None
None
5
SE
6
Vinyl
Low-E Double
Yes
0.7I9 0.28
N
27.2 ft2
2 ft 0 in
1 ft 4 in
None
None
6
NW
9
Vinyl
Low-E Double
Yes
1.0I8 0.3
N
144.0 ft2
10 ft 0 in
1 ft 4 in
None
None
7
SW
11
Vinyl
Low-E Double
Yes
0.JI 0.31
N
9.3 ft2
2 ft 0 in
1 ft 4 in
None
None
8
SW
13
Vinyl
Low-E Double
Yes
0.79 0.28
N
27.2 ft2
2 ft 0 in
1 ft 4 in
None
None
9
NW
14
Vinyl
Low-E Double
Yes
1.08 0.3
N
108.0 ft2
10 ft 0 in
1 ft 4 in
None
None
10
SE
16
Vinyl
Low-E Double
Yes
0.79 0.28
N
27.1 ft2
2 ft 0 in
1 ft 4 in
None
None
11
SW
17
Vinyl
Low-E Double
Yes
0.79 0.28
N
27.1 ft2
2 ft 0 in
1 ft 4 in
None
None
12
NW
23
Vinyl
Low-E Double
Yes
0.79 0.28
N
9.3 ft2
20 ft 0 in
1 ft 4 in
None
None
13
NW
25
Vinyl
Low-E Double
Yes
0.79 0.28
N
24.0 ft2
20 ft 0 in
1 ft 4 in
None
None
14
NW
26
Vinyl
Low-E Double
Yes
1.08 0.3
N
96.0 ft2
10 ft 0 in
1 ft 4 in
None
None
15
SE
29
Vinyl
Low-E Double
Yes
0.79 0.28
N
40.0 ft2
2 ft 0 in
1 ft 4 in
None
None
16
NE
32
Vinyl
Low-E Double
Yes
0.II81 0.31
N
6.8 ft2
2 ft 0 in
1 ft 4 in
None
None
17
NE
33
Vinyl
Low-E Double
Yes
O.II 9 0.28
N
11.7 ft2
2 ft 0 in
1 ft 4 in
None
None
18
NE
34
Vinyl
Low-E Double
Yes
0!79 0.28
N
6.8 ft2
2 ft 0 in
1 ft 4 in
None
None
19
SE
36
Vinyl
Low-E Double
Yes
0166 0.21
N
48.0 ft2
8 ft 0 in
1 ft 4 in
None
None
20
SW
37
Vinyl
Low-E Double
Yes
0179 0.28
N
23.4 ft2
2 ft 0 in
1 ft 4 in
None
None
21
NW
38
Vinyl
Low-E Double
Yes
0.79 0.28
N
96.0 ft2
10 ft 0 in
1 ft 4 in
None
None
22
SE
43
Vinyl
Low-E Double
Yes
0166 0.21
N
40.0 ft2
2 ft 0 in
1 ft 4 in
None
None
23
SW
44
Vinyl
Low-E Double
Yes
OI79 0.28
N
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
24
S
47
Vinyl
Low-E Double
Yes
OI 79 0.28
N
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
(GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
800 ft2
800 ft2
I 50 ft
9.4 ft
11
6/27/2018 1:05 PM EnergyGauge® USA ISection R405.4.1 Compliant Software
Page 6 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
INFILI TRATION
i
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000459
6398.7 351.28 660.63 .3591 7
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity
Block
Ducts
1
2
Electric Strip Heat/
Electric Strip Heat/
None
None
COP:1 34 kBtu/hr
COP:1 27 kBtu/hr
1
2
sys#1
sys#2
COOLING
SYSTEM
#
System Type
Subtype
I Efficiency Capacity Air Flow SHR
Block
Ducts
1
2
Central Unit/
Central Unit/
Split
Split
SEER: 16 46.5 kBtu/hr cfm 0.7
SEER: 16 35.2 kBtu/hr cfm 0.7
1
2
sys#1
sys#2
HOT WATER
SYSTEM
i
#
System Type SubType
Location
EF
I Cap Use SetPnt Conservation
1
Electric Heat Pump
Garage
2
I 80 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
System
Collector Storage
Model # Collector Model # Area Volume
FEF
None None
I
ft2
DUCTS
V #
---- Supply --
Location R-Value Area
---- Return ----
Location Area
Air CFM 25 CFM25
Leakage Type Handler TOT OUT QN
RLF
HVAC #
Heat Cool
1
2
Attic 6 425 ft2
Attic 6 325 ft2
Attic
Attic
105 ft2l
75 ft2
Default Leakage A/C CLST. (Default) (Default)
Default Leakage A/C (Default) (Default)
1 1
2 2
TEMPERATURES
i
Programable Thermostat: Y
CoolingJan Feb Mar
HeatinJan Feb X Mar
Ventin Jan Feb X Mar
Ceiling Faris:
A r May
f Apr f j May
[X A r [ Ma
X Jun X Jul rj Au �Xj Se [ ] Oct
4 Jun 4 Jul AuSep [ ] Oct
[ Jun [ Jul Aug Se [X] Oct
[ ] Nov
[]Nov
[X] Nov
[ j Dec
[X] Dec
j ] Dec
6/27/2018 1:05 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 7 of 8
FORM R405-2017 INPUT SUMMARY C ECKLIST REPORT
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
I 5
6
7
8
9 10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
78
78
78
78
78
78
78 78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78 78
78
78
PM
78
78
78
78
78
78
78
78
78 78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
Beating (WEH)
AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
MASS
Mass Type
Area
(Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
Oft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALL.
Default(8 Ibs/sq.ft.
ft2
ft
0.3
POWDER
Default(8 Ibs/sq.ft.
ft2
ft
0.3
A/C CLST.
Default(8 Ibs/sq.ft.
ft2
ft
0.3
OFFICE
Default(8 Ibs/sq.ft.
ft2
ft
0.3
DINING
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FOYER
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST. 4
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FAMILY ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM #4
Default(8 Ibs/sq.ft.
ft2
ft
0.3
STAIRS
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CABANA
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LOWER FOYER
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LOFT.
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM #3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
STAIRWAY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
A/C
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LOFT
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER SUITE
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
TLT
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM #2
Default(8 Ibs/s .ft.
ft2
ft
0.3
LAUNDRY
Name: Test Rater
Rating Compant: Test Rater
Date:
6/27/2018 1:05 PM EnergyGauge® USAI Section R405.4.1 Compliant Software Page 8 of 8
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: LANDERS RESIDENCE
Builder Name: COASTAL CONSTRUCTION
Street: OCEAN DRIVE
Permit Office: ST. LUCIE COUNTY
City, State, Zip: ST. LUCIE COUNTY, FL,
Permit Number:
Y
U
Owner: GWENDOLYN LANDER
Jurisdiction: ST. LUCIE COUNTY
w
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in they building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with
Ceiling/attic
i
the insulation and any gaps in the air barrier shall be sealed.
/soffit
The insulation in an dropped ceiling/soffit
y pp g
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall
be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior
walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and fralming,
and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier. I
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed
edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shal`
be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints
taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts
exterior or unconditioned space shall be sealed.
opening to
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the gauge
and conditioned spac
Ds.
Recessed lighting
Recessed light fixtures installed in the building
thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall. I_
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent
to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and
tubs.
be insulated.
electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building envelope shall
ithermal
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by, the manufacturer.
Caulking
or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and_WgIls or ceffilonas,
a. in addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
6/27/2018 1:06 PM EnergyGaugeO USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE
ESTIMATED ENERGY
The lower the Energy Performa
EVEL (EPL) DISPLAY CARD
:RFORMANCE INDEX* = 92
Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R 6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 4
13. Cooling system: Capacity 81.7
a) Split system SEER 16.0
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 5313
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average) 7a
b) Solar Heat Gain Coefficient (SHGC) 7b
c) Area 7c
8. Skylights
a) U-factor:(weighted average)
b) Solar Heat Gain Coefficient (SHGC)
9. Floor type, insulation level:
14. Heating system: Capacity 61.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
c) Electric resistance COP 1.0
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
f) Other
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
19.b
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF 2.00
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
20.b
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11 a.
22.0
b) Cross ventilation No
b) Single assembly
11 b.
I
c) Whole house fan No
c) Knee walls/skylight walls
11 c.
I
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
1
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with tfie Florida Building Code, Energy Conservation, through the above energy
saving features which will be in led (or, exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed ed o installed code compliant features.
Builder Signatu
y,S_7v
Address of New Home -
Date: 7116Zg
City/FL Zip: ST. LUCIE COUNTY, FL
6/27/2018 1:06:19 PM EnergyGauge® USA 6.0.02 - �IaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1