Loading...
HomeMy WebLinkAboutPRODUCT APPROVALz" 5/4/2018 F orida Building Code Onlir" QVK.ri L a SCANNED 1 t� Y L BCIS Home Log In User Registration Hot7opi6 SubmitJ2uttt rg� h'fta is Publications FBC Staff . BCIS Site Map b a } Product Approval d r !j�" m " USER: Public User 'V�:Y,.. Product ARo royal Menu > Produc or Aool i n Sea FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Re Address/Phone/Emall Category Subcategory Compliance Method > gp,olicatign Llst > Application Detail FL1654-R22 Revision 2017 Approved POLYGLASS USA 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954) 233-1378 Ext 242 alender@polyglass.com Ariel Lender alender@polygla ss. c o m Maury Alpert 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (912) 429-8610 MA[pert@polyglass.com Ariel Lender 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954) 233-1230 ALender@potyglass.com Roofing Modified Bitumen Roof System Evaluation Report from a Florida Registered Architect or a Licens Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report' Florida License I PE-59166 Quality Assul'ancre Entity UL LLC Quality Assurance Contract Expiration Date 10/06/2018 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Referenced Standard and Year (of Standard) Fi 1654 R22 COI 2017 01 COI Nieminen.pd Standard Year ASTM D6162 2008 ASTM D6163 2008 ASTM D6164 2011 ASTM D6222 2011 pQplA61KxA lgvCZfSdk%o2fiv1%2f1' W)5ryA%3d%3d 1/2 5/4/2018 Florida Building Code Ordir•' — ASTM D6509 2009 • FM 4470 2012 FM 4474 2011 UL 1897 2012 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method 1 Option D 09/14/2017 09/15/2017 09/22/2017 12/12/2017 FL # Modell Number or Name Description 1654.1 Polyglass SBS and APP Modified�SBS and APP modified bitumen roof systems Bitumen Roof Systems `� A Limits of Use Installation Instructions Approved for use in HVHZ: No I F d 6 A P Y� Approved for use outside HVHZ: Yes " - f Impact Resistant: N/A I Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes Other. 1.) The design pressure in this application relates to i Evaluation Reports one particular assembly over] concrete deck. Refer to the ER FL1654 R22 AE 2017 09 FINAL ER POLYGLASS MODE Appendix for other systems and deck types. 2.) Refer to ER, I R22.pdf Section 5 for other Limits oi, Use. Created by Independent Third Party: Yes Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an WEED employer. Qg,(lytight 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: $efun Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records reques electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.139 Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 45S, F.S. must provide the Department with an they have one. The emails' provided may be used for official communication with the licensee. However email addresses are public record. If yo supply a personal addressi please provide the Department with an email address which can be made available to the public To determine if yo under Chapter 455, F.S., please dick here_. Product Approval Accepts: I Credit Card Safe 1 I 1 I I I 1 hitp gMww.floridabuilcirig.org/pr/pr_app dU.aspX?pararrl=wGEVXQwtDq%gqu2W%2bnFgUPv2pw6pKxAhdlgvCZfSdIP/o2bn*lo2fYWFx5rxA%3d%3d 2J2 i APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type Description Page 1A Wood New or Reroof (Tear -Off) A-1 Banded Insulation, Bonded Roof Cover 5 1B-1 Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5-9 1B-2 Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 10-11 1C Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 31 1D Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 12-13 3E Wood New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 14-25 1F-1 Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 16-18 1F-2 Wood New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover 19-21 1G Wood New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 21 2A Steel or Structural concrete New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 22-24 2B Steel or Structural concrete New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 25-28 2C Steel or Structural concrete New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 29-31 3A Structural concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 32-40 3B Structural concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 40 4A LWIC New or Reroof (Tear -Oft) A-1 Bonded Insulation, Bonded Roof Cover 41-42 4B LWIC New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 43 4C LWIC New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 44-46 5A CWF New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 47 SB CWF New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 48 --SC----_CWF New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 49 50 CWF_ New, Reroof (rear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 49 SE CWF __----Ngww, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 49 6A Gypsum Reroof (Tear -Off)—_ A-1 Bonded Insulation, Banded Roof Cover 50-52 6B Gypsum Reroof (Tear -Off) or Recover -A 2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 52 6C Gypsum Reroof (Tear -Off) or Recover C `Mech. Attached Insulation, Bonded.Roof Cover 53 6D Gypsum Reroof (Tear -Off) or Recover E Non -Insulated, Mech.—Attached Base Sheet, Bonded Roof Cover 53 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 54-58 7B Various Recover F Non -Insulated, Banded Base Sheet, Bonded Roof Cover �i 58 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: ➢ Wood: Minimum 0.75-inch penetration. D Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. D Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the CIA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. Exterior Research and Design, LLC. d/b/a Trinity) ERD Certificate of Authorization #9503 Prepared by: Robert Nleminen, PE-59166 61 EDITION (2017) FBC NON.HvHz EVALUATION Polygiass Modified Bitumen Roof Systems; (S70) 384-1230 Evaluation Report P9290.02:08-1120 for FL1654-R22 Revision 20: 09/12/2017 Appendix 1, Page 1 of 58 TPJNITY ERD 4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016). 6. Unless otherwise noted, insulation adhesive application rates areas follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ Hot asphalt (HA): Full coverage at 25-30lbs/square. ➢ Dow INSTA STIK Quik Set Insulation Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. ➢ Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-Inch wide ribbons, 12-inch o.c. ➢ Millennium PG-1 Pump Grade Adhesive (M-PG1): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c. ➢ OMG OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced. ` ➢ OlyBond Classic (08 Classic): Full coverage at 1 gal/square. ➢ ICP Adhesive & Sealants CR-20: Continuous 2.5-3.5-Inch wide ribbons, 12-inch o.c. ➢ Note: when multiple layersfs) of insulation and/or coverboard are Installed in ribbon -applied adhesive, board joints shall be staggered. D Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted, all Insulations are flat -stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed fora particular system in the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table: ➢ Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick) ➢ Millennium PG-1 Pump Grade Adhesive (M-PG3): MDP -157.5 psf (Min. 0.5-inch thick) ➢ OMG OlyBond 500 (06500): MDP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3) _ ➢ OMG OlyBond 500 (OB500): MDP -187.5 psf (Min. 0.5-Inch thick ISO 95+GL) ➢ OMG OlyBond 500 (OB500): MDP -315.0 psf (Min. 0.5-inch thick ENRGY 3) '➢-OMG.OlyBt500 (OB500): MDP -487.5 psf (Min. 0.5-inch thick ACFoam II) ➢ ICP Adhesives 9 Sealants CR_20: MDP -117.5 psf (Min.1.0-inch thick) 8. Bonded polyisocyanurate insulation boards shall be maximum 4-x.4-ft. 9. For mechanically attached components or partially bonded insulation, the maximum d0gn-pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design prof less onal-to-resist t�levated pressure criteria. Commonly used methods are AN51/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked -with -an -asterisk' carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. --_ 10. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no a-tional-analysis is permitted. 11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with AN51/SPRI FX-1 orTesting Application Standard TAS 105. 12. For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data. Sheet 1-52 or Testing Application Standard TAS 124. 13. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application. 14. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-Inches. For LWC over structural concrete, reference is made to FBC Section 1917.4.1„Point 1. Exterior Research and Design, U.C. d/b/a Trinityl ERD Evaluation Report P9290.02.08-R20 for FU654-M Certificate of Authorization #9503 GP EDITION (2017) FBC N0N-HVHZ EVALUATION Revision 20: 09/12/2017 Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 2 of 58 TRI Vf f ER Entity Examination Reference Date ERD (TST11294) FM 4474/UL1897/TAS 114 PLYG-CTL33945.05.17-3 05/30/2017 ERD (TST6049) FM 4474/UL1897 PLYG-SC13945.05.17 05/30/2017 ERD (TST6049) FM 4474/TAS 4 PLYG-SC15760.09.17 09/11/2017 FM Approvals (TST1867) FM 4470 2W7A7.AM 09/04/1994 FM Approvals (TST1867) FM 4470 OD3A3.AM 04/04/1997 FM Approvals (TST1867) FM 4470 2DOAO.AM 12/23/1998 FM Approvals (TST1867) FM 4470 2D5A9.AM 06/22/1999 FM Approvals (TST1867) FM 4470 3006646 01/04/2000 FM Approvals (TST1867) FM 4470 3001334 01/25/2000 FM Approvals (TST1867) FM 4470 3001334 02/15/2000 FM Approvals (TST1867) FM 4470 3000857 01/12/2000 FM Approvals (TST1867) FM 4470 3004091 01/12/2000 FM Approvals (TST1867) FM 4470 3006115 05/02/2001 FM Approvals (TST1867) FM 4470 3012321 07/29/2002 FM Approvals (TST1867) FM 4470 3014692 08/05/2003 FM Approvals (TST1867) FM 4470 3014751 08/27/2003 FM Approvals (TST1867) FM 4470 3007170 01/13/2004 FM Approvals (TST1867) FM 4470 3019317 06/30/2004 FM Approvals(TST1867) FM 4470 3020703 07/30/2004 FM Approvals (TST1867) FM 4470/4474 3028332 01/31/2006 FM Approvals (TST1867) FM 4470/4474 3023368 03/20/2006 FM Approvals (TST1867) FM 4470/4474 3024594 05/23/2006 FM Approvals (TST1867) FM14470/4474 3023458 07/18/2006 FM Approvals (TST1867) FM 4470/4474 3030668 09/12/2007 FM Approvals (TST1867) FM 4470/4474 3032172 06/12/2009 FM Approvals (TST1867) FM 4470/4474 3049631 04/21/2014 FM Approvals (TST1867) FM 4470/4474 3057029 02/02/2017 PRI(TSTS878) Physical Properties PUSA-062-02-01 12/04/2007 PRI (TST5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI(TST5878) Physical Properties PUSA-064-02-02 02/27/2008 PRI (TST5878) Physical Properties PUSA-062-02-02 12/04/2008 PRI(TSTS878) TAS 114 PUSA-188-02-01 02/08/2017 PRI (TST5878) TAS 114 PUSA-188-02-02 02/08/2017 PRI (TST5878) TAS 114 PUSA-188-02-03 02/08/2017 PRI (TST5878) TAS 114 PUSA-202-02-01 05/17/2017 PRI (TST5878) TAS 114 PUSA-202-02-02 05/17/2017 Miami -Dade (CER1592) HVHZ Compliance Various NOAs Various Miami -Dade (CER1592) Proposal for Review 30-0823 10/12/2010 UL LLC (QUA9625) Quality Control Service Confirmation, R14571 Exp.10/06/2018 4. PRODUCT DESCRIP- This Evaluation Report covers Polyglass Modified Bitumen Roof Systems installed in accordance with Polyglass USA, Inc. published installation instructions and the Limitations / Conditions of Use herein. The following Polyglass membranes make up the subject systems. ' TABLE 1: ROLL -GOODS FOR POLYGLASS MODIFIED BITUMEN ROOF SYSTEMS Type ( Product Specification Reference Grade Type Base Sheets Polyglass G2 Base ASTM D4601 N/A II Polyflex SA Base ASTM D4601 N/A II Polyglass APP Base ASTM D6509 N/A N/A 1 Exterior Research and Design, I.I.C. Certificate ofAuthori:ation #9503 I I Evaluation Report P9290.02.08-R20 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL1654-R22 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Revision 20: 09/12/2017 Page 3 of 6 ¢fad 1{ 8 1 -.-- ` i t TABLE 1(CONTINUED): ROLL -GOODS FOR POLYGLASS MODIFIED BITUMEN ROOF SYSTEMS Type I Product Specification Reference Grade Type SOS Membranes Polyglass HT Base,650 ASTM D6162 S III Elastobase I ASTM D6163 S I Elastoflex V I ASTM D6163 S I Elastoflex SA V Base ASTM D6163, Table 2 S 1 E4astoftex SA V FR Base ASTM D6163, Table 2 S I E as o ex In ASTM D6163 S I Elastoflex SA V Plus FR ASTM D6163 S I Elastobase Pol I ASTM D6164 S- I Elastoflex S6 I ASTM D6164 S I Elastoflex S6 Type 11 ASTM D6164 S 11 Elastoflex VG I ASTM D6163 G I Elastoflex VG FR ASTM D6163 G I SOS Membranes Elastoflex S6 G ASTM D6164 G I Elastoflex S6 G FR ASTM D6164 G I Polyfresko G SOS sand or poly -film backed ASTM D6164 G I Polyfresko GiSBS FR sand orpoly-film backed) ASTM D6264 G I Elastoshield ITS G ASTM D6164 G I ElastoshieldlTS G FR ASTM D6164 G I Elastoflex SA P ASTM D6164 G I Elastoflex SA P FR ASTM D6164 G I Polyreflectl ASTM 06164 S I APP Membranes Polyflex I ASTM D6222 S I Polyflex G I ASTM D6222 G I Polyflex GIFR ASTM D6222 G I Polyfresk6 G ASTM D6222 G 1. Polyfresko G FR ASTM D6222 G I Polybond ASTM D6222 S I Polybond_G ASTM D6222 G I Palyfl�x SAP ASTM D6222 G I o yflexj A R ASTM D6222 G I Polyfreiko G SA ASTM D6222 G I Polykool ASTM D6222 5 1 5. LIMITATIONS: 5.1 This is a building code Designer of Record for ai for permitting or design 1 5.2• This Evaluation Report is 5.3 Refer to a current Appro, 5.4 For steel deck installatioi with FBC 2603.4 unless tl 5.5 The roof system evalu members shall be in Jurisdiction. Load resisat Approval documentation 5.6 For recover installations, aluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the project on which this Evaluation Report, or previous versions thereof, is/was used dance unless retained specifically for that purpose. It for use in FBC HVHZ jurisdictions. i Roofing Materials Directory for fire ratings of this product. foam plastic insulation shall be separated from the building interior in accordance exceptions stated in FBC 2603.4.1 and 2603.6 apply. n herein pertains to above -deck roof components. Roof decks and structural ordance with FBC requirements to the satisfaction of the Authority Having ice of the roof deck shall be documented through proper codified and/or FBC the existing roof shall be examined in accordance with FBC 1511. I I Exterior Research and Design, LLC. I Certiflcote of Authorization #9503 1 6 EDITION (2017) FBC NON-HVHZ EVALUATION I Polyglass Modified Bitumen Roof Systems; (570) 384-1230 I I Evaluation Report P9290.02.08-R20 FL16S4-R22 Revision 20: 09/12/2017 Page 4 of 6 TRINITY Eta TABLE 1F-2: WOOD DECKS- NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (sCREws & PLATES), BONDED ROOF COVER System Base Sheet Roof Cover (Note 15) MDP No. I Deck (Note 1) Type Fasten Attach Base Ply Cap (PsQ SEIF-ADHERING BASE PLW.. Min.19/32- Elastobase, Elastobase P Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14 12-inch o.c. in 4-inch lap and 12-inch o.c in two SBS-SA SBS-SA, APP-SA, SBS- .52.5• W-136 inch plywood (poly -film top) or Trufast 3" Metal Insulation Plate with Trufast HD (2), equally spaced, staggered center rows TA, APP-TA W-137 Min.19/32- Elastobase, Elastobase P Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14 12-inch o.c. in 4-Inch lap and 12-inch me in two Polyflex SA Base APP TA -52.5• inch plywood (poly -film top) or Trufast 3" Metal Insulation Plate with Trufast HD (2), equally spaced, staggered center rows W-138 Min. 19/32- Elastobase, Elastobase P OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c, in 4-inch lap and 12-inch o.c. in two SBS-SA SBS-SA, APP-SA, SBS- 60.0 inch plywood (poly -film top) (2), equally spaced, staggered center rows TA, APP TA W-139 Min. 19/32- Elastobase, Elastobase P OMG Flat Bottom Plates (square) with Roofgrip #12 12-Inch o.c. in 4-inch lap and 12-inch a.c. in two Polyflex SA Base APP-TA 60.0 , inch plywood (poly -film top) (2), equally spaced, staggered center rows TABLE iG: WOOD DECKS —NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER System Deck (Note 1) Primer Roof Cover (Note 15) MOP (psi) Joint Treatment Base Ply Ply Cap Ply No. W-140 frfin,.i5/32- Norse None SBS SA L1ptEonai SBS-SA SBS BS Sq,APP-SA,S10 90:0 plywood �R_T W-141 Min.15/32- (Optional) PG100 None —RolyflexSA Base (Optional) APP-TA APP TA -90.0 inch plywood W-142 Min. 15/32- PG300 None SBS-SA (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS- 97 5 inch plywood TA, APP-TA TA, APP-TA W-143 Min.15/32- (Optional) PG100 Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into Elastoflex SA V Base or (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS- 97.5 inch plywood place to create continuous bond. Elastoflex SA V FR Base TA, APP-TA TA, APP-TA W-144 Min.15/32- W 8-300D None SBS-SA (Optional) SBS-SA, APP-SA, SBS- 105.0 inch plywood TA, APP TA Min.15/32- Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into Elastoflex SA V Plus or (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS- (Optional) PG100 place to create continuous bond. Elastoflex SA V Plus FR TA, APP-TA TA, APP-TA 135.0 W-146 Min. 15/32- (Optional) PG100 Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into Polyflex SA Base (Optional) APP-TA APPTA 135.0 Inch plywood place to create continuous bond. Exterior lResearch and Design, LLC. d/b/a Trinity' ERD Certificate of Authorization f19S03 Prepared by: Robert Nieminen, PE-59166 0 EDITION (2017) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (570) 384-IM Evaluation Report P9290.02.08-R20 for FL1654-R22 Revision 20: 09/12/2017 Appendix 1, Page 21 of 58