HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCERECEI"D OUP' 02 2015
Planning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
v Project Name: TARPON FLATS LOT 23 MODEL A
Project Address: 3915 Duneside Drive Ft. Pierce, FL.
Permit #: Occupancy Type: R-3 Construction Type: V-B
INSTRUCTIONS FOR USE: SCANNED,
• This certification must be correlated, signed, and sealed by the design professional of record.
• Submit 2 () copies for M i
Evdl&��i�s for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretiion of the local building official. Contact the # above for questions.
i
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 Supplements using ASCE 7-10
i
2. Structure Designed as (check one): X I Enclosed Partially Enclosed Open
3. Risk Category: _I X II III IV Exposure Category: B X C D
4. Design Wind Velocity 170 mph ASD LRFD End Zone Width: ft
5.. Mean Roof Height 15.44' ft Roof Pitch: 6 :12 Parapet: ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: -44.63 Zone 2: -74.76 Zone 3: -74.76 Zone 4: -45.6 Zone 5: -57.8 Garage:
7. Design Loads: Floor: 138 PSF Roof/Dead: 35 PSF Roof/Live: 20 Balcony: PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Struci ure? X Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X, Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2,500 PSF Soil Test Reports Submitted? X Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge Iand belief, the attached plans & specifications have been designed to
comply with the applicable structural portiions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified: \�� 11 I i I ► l ���
&IBU Gq T ��,, j Farid Abugattas 7 ;,'71
f% (I n
ENS �q�� Print Name
2471 — Project Classic LLC
Signaturd;%te: and Seal _i 7318 Texas Trail, Boca Raton, FL. 33487
UJ
STATE OF Z 44/ Company Name & Address
FLOR10? • �\
Revised 07/2�/'J��Ois% • .. • . . . F� ,.� CHECKED NOV 0 9 2015