HomeMy WebLinkAboutMANDATORY REQUIREMENTSmunab. elan, ig R t= t l '.J FORM R496--2014 J�°� 0 2 2015 Florida Department of Busii�WWrofessional Regulations Residential Whole Building Performance and Prescriptive Methods I ADDRESS: I Permit Number: I Fort Pierce, FL , MANDATORY REQUIREMENTS See individual code sections for full details. ❑ 401.3 Energy Performance Level (EPL) display card (Mandatory). I The building official shall require that an energy performance level (EPL) ` display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law [Section 553.9085, Florida Statues] requires the EPL display card to ble included as an addendum to each sales contract for both presold and . nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the buildij�g. A copy of the EPL display card can be found in Appendix C. ❑ R402.4 Air leakage (Mandatory). The building thermal envelope siall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and illthe criteria listed in Table 402.4.1.1, as applicable. to the method of construction. Where required by the code official; an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit I hall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2, and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Where required by the code official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stoldoors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures; ' 2. Dampers including exhaust, intake, makeup air,lbackdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures; 3. Interior doors, if installed at the time of the test,'shall be open; 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5. Heating and cooling systems, if installed at the time of the test, shall be turned off; and 6. Supply and return registers, if installed at the time of the test, shall be fully open. O R402.4.2 Fireplaces. New wood-burning.fireplaces shall have tight -fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage. Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site -built windows, skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E 283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. ❑ R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat (Mandatory). Heatlpumps having supplementary electric -resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.2.2 Sealing (Mandatory)AII ducts, air handlers, and filter i boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers, shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post -construction or rough -in testing below. Duct tightness shall be verified by testing to Section 803 of the:RESNET Standards by either an energy rater certified in accordance with Section 553.99, Florida Statutes, or as authorized by Florida Statutes, to be "substantially leak free" by either of the following: 1. Post -construction test: Total leakage shall be less than or equal to 4 cfm (113 Umin) per 100 square feet (9.29 m2) of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. All register boots shall be taped or otherwise sealed during the test. 2. Rough -in test: Total leakage shall be less than or equal ,to 4 cfm (113 Umin) per 100 square feet (9.29 m2) of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25Pa) across the system, including the manufacturer's air handler enclosure. All registers shall be taped or otherwise sealed during the test. If the air handler is not installed at the time of the test, total leakage shall be less than or equal to 3 cfm (85 Umin) per 100 square feet (9.29 m2) of conditioned floor area. ° Exceptions: 1. The total leakage test is not required for ducts and'air handlers located entirely within the building en FILE 2. ' Duct testing is not mandatory for buildings complying by Section R405 of this code. 11/20/2015 1:46 PM EnergyGauge@ USA 1FlaRes2014 - Section R405.4.1 Com Page f FORM R405-2014 MANDATORY REQUIREMENTS - (Contin O R403.2.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design air flow rate when tested in accordance with ASHRAP 193. El R403.2.3 Building Cavities (Mandatory). Building framing cavities s�all not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41 °C) or below 55 OF (13 °C) shall be insulated to a minimum of R-3., O R403.3.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance, and wind, alhd shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. l ❑ R403.4.1 Circulating hot water systems (Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the; hot-water circulating p l mp when the system is not in use. ❑ R403.4.3 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches (89 mm) in the hol water distribution line and cold water line located as close as possible to the storage tank, ❑ R403.4.4 Water heater efficiencies (Mandatory). Water heater efficiencies O R403.4.4.1 Storage water heater temperature controls R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 100°F to 140°F (38•°C to 60'C). R403.4.4.1.2 Shutdown. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. O R403.4.4.2 Water heating equipment: Water heatingequipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters.shall,met the criteria Section R403.4.4.2.1. R403.4.4.2.1 Solar water heating systems. Solar] systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol, Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventilation (Mandatory). The building shall 6e provided with ventilation that meets the requirements of the Florida Building Code, Residential or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation. Outdoor air intakes and exhausts shall have`automatic or gravity dampers that close when the ventilation system is not operating. O R403.5.1 Whole -house mechanical ventilation syste i fan efficacy. Mechanical ventilation system fans shall meet the efficacy requirements of Table R403.5.1. i Exception: Where mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be powered by an electronically commutated motor. i o R403.5.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2• No ventilation or air-conditioned system make air shall be provided to conditioned space from attics, crawlspaces, attached closed garages or outdoor spaces adjacent to swimming; pools or spas. 3. If ventilation air is drawn from enclosed spaces(s)} then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum or R-19, space permitting, or R-10 otherwise. ❑ R403.6 Heating and cooling equipment (Mandatory).. The following sections are mandatory for cooling and heating equipment. O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This code does not allow designer safety factors, provisions for future expansion or other factors which affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that ca � a ity' t calculated total load, but not more than 1.15 times greater than the total load calculated accord t e ed e s ec Section 403.6, or the closest available size provided by the manufacturer's product lines. The c ndi g at t c y equipment shall not be less than the calculated latent load. 11/20/2015 1:46 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Com Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continu O R403.6.1.1 Cooling equipment capacity. (continued) The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacture's expa nded performance data shall be used to select cooling -only equipment. This selection shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry bulb temperature for the load calculation (or entering water temperature for water -soul rce equipment), the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the Yeturn duct(s) is installed in an unconditioned space. Exceptions: 1. Attached single- and multi -family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida -registered engineer, in attached single- and multi -family units, the capacity of equipment may be sized in accordance with good design practice. o R403.6.1.2 Heating equipment capacity R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. O R403.6.1.3 Extra capacity required for special occasior1S. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized) to provide cooling or heating to the major entertainment areas. R 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units (Mandatory). I Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls (Mandatory). Snow and ice -melting systems, supplied. through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 551F, and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40OF. . ❑ R403.9 Swimming pools, inground spas and portable spas (Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15. The energy requirements for portable spas shall be in accordance with ANSI/AP,SP-14. i O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on -off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil -fired pool and spa heaters. All gas- and oil -fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16, 2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps. Heaters, pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-11our pump operations. 2. Where pumps are required to operate solar- and waste -heat -recovery pool heating systems. 3. Where pumps are powered exclusively from on -site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor -retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site -recovered energy, such as a heat pump or solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment (Mandatory). A minimum of 75�percent of the lamps in permanently installed lighting fixtures shall be high -efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low -voltage lighting shall not be required to utilize high -efficacy lamps. $ O R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have con ' bnal ig 11%l 4-1pbeaytype ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to i u R O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19. Where single asse +by I e x os or concrete deck roofs do not have sufficent space, R-10 is allowed. 11/20/2015 1:46 PM EnergyGaugeO USA - FlaRes2014 - Section R405.4.1 Com Page 3 of 3 Manual S Compliance Report Job: L .18.14rponFlatsModel... -- �nrrights®f$® p p Date: 01.18.14 Entire House By: ER DEL -AIR HEATING & AIR CONDITIONING N 531 CODISCO WAY, SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 For: Phoenix Realty Homes Inc FL Design Conditions Outdoor design DB: 90.0 OF Sensible gain: 33532 Btuh Entering coil DB: 77.8°F Outdoor design WB: 78.0°F Latent gain: 5883 Btuh Entering coil WB: 64.0°F Indoor design DB: 75.0 OF Total gain: 39415 Btuh Indoor RH: 50% Estimated airflow: 1533 cfm I Manufacturers Performance Data at Actual Design Conditions i Equipment type: SplitASHP j ' Manufacturer: Carrier Model: CH14NB048****A+FB4CNP048L Actual airflow: 1533 cfm Sensible capacity: 34184 Btuh 102% of load Latent capacity: 6171 Btuh 105% of load j Total capacity: 40355 Btuh 102% of load SHR: 85% Design Conditions Outdoor design DB: 42.0 `F Heat loss: 29439 Btuh Entering coil DB: 69.1 OF Indoor design DB: 70:0 °F Manufacturer's Performance Data at Actual De'sign Conditions Equipment type: Split ASHP Manufacturer: Carrier Model:.CH.14NBO48****A+FB4CNP048L Actual airflow: 1533 cfm Output capacity: 44237 Btuh 150% of load Capacity balance: 31 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1533 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 OF The above equipment was selected in accordance with ACCA Manual S. 1 i P -- wri htsoft- CNOPY ,�„ � Right -Suite® Universal 201515.0.18 RSU08057 l'Ck...ot23TarponRatsAGL\Lot23TarponFlatsModelAGL.rup Calc=W8 Housefaces: E FILE { = - wrightsoft- Component Constructions Entire House DEL -AIR HEATING & AIR CONDITIONIM 531 CODISCO WAY, SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web: W W W.DEL-AIR.COM For: Phoenix Realty Homes Inc FL Job: Lot23TarponFlatsModel... Date: 01.18.14 By: ER Location: Fort Pierce, FL, US Elevation: 25 ft Latitude: 27 °N Outdoor: Heating Cooling Dry bulb (OF) 42 90 Daily range (OF) - 15 ( L Wet bulb ff) - 78 Wind speed (mph) 15.0 7.5 Indoor: Heating Indoor temperature (T) 70 Design TD (T) 28 Relative humidity (%) 30 Moisture difference (gr/lb) - 1.1 Infiltration: - Method Simplified Construction quality Average Fireplaces 0 Cooling 75 15 50 61.5 Construction descriptions Or Area u-value Insul R Htg HTM Loss Clg HTM Gain ft� Btuh/ft'- F ft2-`F/Btuh Btuh/ft� Btuh Btuhfft� Btuh Walls 13A-2ocs: Bilk wall, stucco ext, r-2 ext bd ins, 8" thk, 1/2" gypsum board n 431 0.201 0 5.63 2427 4.00 1725 int fnsh a 246 0.201 0 5.63 1382 4.00 982 s 380 0.201 0 5.63 2136 4.00 1518 w 314 0.201 0 5.63 1767 4.00 1256 all 1370 0.201 0 5.63 7711 4.00 5480 Partitions 126-0sw: Frm wall, r-11 cav ins, 2"x4" wood frm, 16" o.c. stud j I 318 0.097 11.0 2.72 863 1.57 500 Windows' 2A-2om: 2 glazing, clr low-e outr, air gas, mtl no brk frm mat; dr inns, In 13 0.270 0 7.56 101 8.24 110 1/4" gap, 1/8" thk; NFRC rated (SHGC=0.28); 50% drapes, medium; 2 ft I overhang (5 ft window ht, 0.33 ft sep.); 6.67 ft head ht lall n 27 0.270 0 7.56 202 8.24 220 40 0.270 0 7.56 302 8.24 330 10C-m: 2 glazing, drlow-e outr, air gas, mtl no brkfrm mat, clr innr, 1/4" le 24 0.270 0 7.56 181 10.3 247 gap, 1/8" thk; NFRC rated (SHGC=0.28); 9.17 ft overhang (8 ft window a 10 0.270 0 7.56 76 14.7 147 ht, 1.42 ft sep.); 6.67 ft head ht I all 34 0.270 0 7.56 257 11.6 393 2A-2om: 2 glazing, clr low-e outr, air gas, mtl no brk frm mat, clr innr, I e 8 0.270 0 7.56 63 20.4 170 1/4" gap, 118" thk; NFRC rated (SHGC=0.28); 50% drapes, medium; 2 ft overhang (4.17 ft window ht, 0.33 ft sep.); 6.67 ft head ht l 2A-2om: 2 glazing, clr low-e outr, air gas, mtl no brk frm mat, cir innr, a 31 0.270 0 7.56 234 21.5 667 1/4" gap, 1/8" thk; NFRC rated (SHGC=0.28); 50% drapes, medium; 2 ft overhang (5.17 ft window ht, 0.33 ft sep.); 6.67 ft head ht 2A-2om: 2 glazing, clr low-e outr, air gas, mtl no brk frm mat, dr innr, a 31 0.270 0 7.56 234 22.4 694 1/4" gap, 1/8" thk; NFRC rated (SHGC=0.28); 50% drapes, medium; 3 ft' overhang (5.17 ft window ht, 1.42 ft sep.); 6.67 ft head ht 10C-m: 2 glazing, dr low-e outr, air gas, mtl no brk frm mat, dr innr, 1/4", s 20 0.270 0 7.56 151 6.94 139 gap, 1/8" thk; NFRC rated (SHGC=0.28); 18.67 ft overhang (8 ft window! ht, 0.25 ft sep.); 6.67 ft head ht 1 A a'Q: wri htsOft' COPY Right-SuiteC� Universal 201515.0.18 RSU08057 ACCk...ot23TarponFlatsAGLtLot23TarponFlatsModelAGL.rup Calc=W8 Housefaces: E FILE," I I T � � ,2A-2om: 2 glazing, clr low-e outr, air gas, mtl no brk frm mat, clr innr, I I I s I 6 0.270 0 1/4" gap, 1/8" thk; NFRC rated (SHGC=0.28); 50% drapes, medium; 2 ft overhang (3.17 It window ht, 0.33 ft sep.); 6.67 ft head ht 2A-2om: 2 glazing, clr I w-e outr, air gas, mtl no brk frm mat, dr innr, w 1 84 0.270 0 1/4" gap, 1/8" thk; NFRC rated (SHGC=0.28); 50% drapes, medium; 2 ft w 1 32 0.270 0 R overhang (6.33 ft window ht, 0.33 ft sep.); 6.67 ft head ht w I 34 0.270 0 all 150 0.270 0 2A-2omd: 2 glazing, clr low-e outr, air gas, mtl no brk frm mat, clr innr, w I 96 0.270 0 1/4" gap, 1/8" thk; NFRC rated (SHGC=0.28); 13 ft overhang (8 ft • window ht, 0.25 ft sep.); 6.67 ft head ht i I Doors 11 D0: Door, wd sc type n 23 0.390 0 Ceilings I 16X19-Oad: Attic ceiling, asphalt shingles roof mat, r-20 roof ins, 1/2" 2051 0.408 19.0 gypsum board int fnsh Floors 22A-tpl: Bg floor, light dry soil, on grade depth I 192 0.989 0 7.56 48 8.24 52 7.56 638 22.4 1888 7.56 239 22.4 708 7.56 255 22.4 755 7.56 1133 22.4 3352 7.56 726 9.92 952 10.9 248 11.3 256 1.59 3252 1.49 3048 27.7 5303 0 0 I D D I t Wra h�tsOflt' 2015-Nov-2013:5223 MCA � Right -Suite® Universal RSU08�057 Page ot23TarponRatsAGL\Lot23TarponRatsModelAGL.rup Cale=W8 House faces: E ' j Job: LotMarponFlatsModel ft... 1- Wrightso� Project Summary Date: 01.18.14 Entire House I By: ER DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web: W I W.DEL-AIR.COM I :Pr • hform. afforli., For: Phoenix Realty Homes Inc FL Notes: LS BY SIR 11.16.15 Weather: Fort Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 °F + Heating Summary Structure 23667 Btuh Ducts 5772 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 29439 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heating Cooling Area (ft2) 2048 2048 Volume (ft3) 19140 19140 Air changes/hour 0.32 0.16 Equiv. AVF (cfm) 102 51 Heating Equipment Summary Make Carrier Trade CARRIER Model CH 14N B048****A AH R I ref 7835757 Efficiency Heating input Heating output Temperature rise Actual air -flow Air flow factor Static pressure Space thermostat 8.2 HSPF 45500 Btuh @ 47,°F 27 OF 1533 cfm 0.052 cfm/Btuh 0.30 in H2O i FL, US Summer.Design Conditions Outside.db 90 OF Inside db 75 OF Design TD 15 `F Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 23949 Btuh Ducts 9583 Btuh Central vent (0 cfm) 0 Btuh Blower. 0 Btuh Use manufacturer's data Rate/swing multiplier 1.00 Equipment sensible load 33532 Btuh Latent Cooling Equipment Load Sizing Structure 3132 Btuh Ducts 2751 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 5883 Btuh Equipment total load 39415 Btuh;. Req. total capacity at 0.75 SHR 3.7 ton Cooling Equipment Summary Make Carrier Trade CARRIER Cond CH14NB048****A Coil FB4CNP048L AH R I ref 7835757 Efficiency 11.7 EER, 14 SEER Sensible cooling 34500 Btuh Latent cooling 11500 Btuh Total cooling 46000 Btuh Actual air flow 1533 cfm Air flow factor 0.046 cfm/Btuh Static pressure 0.30 in H2O Load sensible heat ratio 0.85 E Calculations approved by ACCA to meet all requirements of Manual J 8th s wrightSOft' Right -Suite® Universal 2015 15.0.18 RSU08057 ACC'...ot23TarponFlatsAGL\Lot23TarponFlatsModelAGL.rup Calc= W8 House faces: E e rF wrightsoft, Right-M Worksheet Entire House DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web: W,W W.DEL-AIR.COM Job: Lot23TarponFlatsModeIAGLW Date: 01.18.14 By: ER 1 Room name I Entire House ms bdrm 2 Exposed wall 191.5 ft 45.0 ft 3 Room height 9.3 it 9.3 ft heat/cool 4 Room dimensions 16.5 x 17.0 ft 5 Room area 2051.5 ft2 280.5 ft2 Ty Construction number U-value (Btuh/ft2-IF) Or HTM (Btuh/ft� Area (ft2) or perimeter (it) Load (Btuh) Area (w) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WKS Heat Cool 6 W:- 13A 2ocs _ 2A 2om 2A-2om_ 0.201 0.270 n n - 5.63 7.56 7.56 4.00, 8.24 8.24 1471 113 127 431 ` 0 _ -0 2427 101 202 1725 110 -- -- 220 - 159 0 - 0 i59' ' 0 0 893 0 - 0 634 0 -- 0 11 - - 13A-2ocs 1OC-m - ---0.270 0.201 0.270 _n_ a a _ 5.63 7.56 4.00 10.27 350 24 246 37 1382 181 982 247 0 0 0 0 6 0 0 0 2A-2om 2A-2om 2A-2om 0.270 0.270 0.270 a a a 7.56 7.56 7.56 14.68 20.42 21.52 10 8 31 15 5 16 76 63 234 147 170 667 0 0 0 0 0 0 0 0 0 0 0 0 2A-2om_ _ 13A-2ocs _ 0.270 0.201 a s 7.56 5.63 22.39 4:00 31 406 _ _ ___13 380 _,_._234 2136 694 - 1518 - _ _ -0 107 _ _ _0 87 _ _ _ _0 ' 491 __ _0 349 V)! I�--G 10c-m' '2A-2om_ _ 13A-2ocs 0.270 _ _ _0.270 0.201 s _=s_ w 7.56 _7.56 5.63 6.94. 8:24 4.00 20 _ _ ___6 660 40 _13, 314 151 48 1767 139 _ - __62 1256 - 20 _ 0 154 ! 20 _ 0 89 151 . ____0 498 139 _ _ 0 354 G _ 2A-2om 2A-2om 0.270 0.270 w w 7.56 7.56 22.36 22.36 84 32 35 13 638 239 18W 708 34 32 7 7 255 239 755 708 2A-2om 0.270 w 7.56 22:36 34 14 255 755 0 0 0 0 .2A-2omd _ 12B-Osw _-=0.270- 0.097 w_ ' - __ 7.56 272 --9.92 1.57' __96 341 _____ 192 318 726 863 ___._952 500 .__ __ 0_ 0_ 0 0 0 0. PI' - 11D0.- --- - 16X19-Oad -- -0.390 _0.408 n, - 10.92 1.59 11.31' .1.49 - - - 23 _-_2051 --' --.23 _-_ 2051 - - --248 3252 - -- --256 3048. -- 0 _281 --- -0 281. -- --_ 0 __. ..__445 ---0 . ____ 417 -_ -�D C F'_ . _ 22A-tpl -. _0:989 27.69 - 0.00- 2051 - 192 5303' - -_. 0 _ _. 281 . 45 = 1246 _ __0 - -- 6 c) AED excursion 3523 869 Envelope loss/gain 20526 19557 4219 4226 12 a) Infiltration 3141 841 - 738 198 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 5 1150 1 230 Appliances/other 2400 600 Subtotal (lines 6 to 13) 23667 23949 4957 5254 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 23667 23949 4957 5254 15 Duct loads 1 241/, 40% 5772 9583 24°/ 400/6 1209 2102 Total room load 29439 33532 6166 7356 Air required (cfm) 1533 1533 321 336 Calculations awroved bvACCA to; meet all reauirements of wrightso t- Right -Suite® Universal2015 15.0.18 RSU08067 AGCK...ot23TarponFlatsAGL\Lot23TarponRatsModelAGL.rup CaIc=W8 Housefaces: E 3:52:23 Page 1 - + wriOtsoftx Right-JO Worksheet Entire House DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web: W W W.DEL-AIR.COM Job: Lot23TarponF1atsModeIAGLW Date: 01.18.14 By: ER 1 Room name we wic 2 Exposed wall 1 6.0 ft 0 ft 3 Room height 9.3 ft heat/cool 9.3 ft heat/cool 4 5 Room dimensions Room area 1 4.5 x 6.0 ft 27.0 ft2 6.0 x 11.5 ft 69.0 ft2 Ty Construction number U-value (Btuh/ftZ°F) Or HTM (Btuh/ft2) Area I (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat. Cool Gross WP/S Heat Cool 6 13A-2ocs 2A-tom 2A-26m- -- - - 0.201 0270 _0:270 - • n n. - - 5.63 7.56 ---7.56 -- 4:06 8.24 -8:24 1 56 i 13 0 - - 43 0 0 --- 101 101 0 - - 110 110 0' - 0 0 0 - --- 0 - b '_ 0 - 0 0 _ _0 0 0 0 11 13A-2ocs 10C-m - - 0.201 0.270 _n a a 5.63 7.56 4.00 10.27 1 0 1 0 0 0 0 0 0 .0 0 0 0 0 0 0 0 0 2A-2om 2A-2om 2A-2om 0.270 0.270 0.270 a a a 7.56 7.56 7.56 14.68 20:42 21.52 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2A-2om 13A-2ocs - -0.270 0201 - _e-. s; _ ._-_7.56 5.63 22.39 4.00 - - _0 .0 - 0 0 - - 0 0 - - -0 0 0 0 - -- --0 0 --0 0 -- -0 .0 - - 10C-m '.2om - - - 13A-2ocs 0.270 -- 0.270 0.201 s -s w 7.56 ---7.56 5.63 6.94 8.24 4.00 0 _ _.0 0 0 0 0 0 - 0 0= - - 0' 0 0 - -- 0 0 0 -. ----0 0 0 0 0 0 - 0 -- 2A-2om 0.270 w 7.56 22.36 0 0 0 0 0 0 0 0 2A-2om 0.270 w 7.56 22.36 0 0 0 0 0 0 0 0 2A-2om 0.270 w 7.56 22.36 0 0 0 0 0 0 0 0 --- - P 2A-2cmd - 12B-0sw --0.270 0.097 --w _7.56 2.72 - - 9.92 1.57 ---- -0. 0 0 01 - 0 0 - -- 0 0 - - 0 0 - -0 0 - -0 0 11D0-_-._-- _-- 16X19.0ad ----0:390__n-____10.92_._11.31. 0.408 1.49 _-0 �7- -____0 27 --0 - 43 ___-0 -- -- - - 40 _____0__ -- - - - -69 - _,__0 - ---- - - 69 -_-0 -- -- --109 ---- - 103 C _ _ F _ _ -- .2?lA tpl - _ ;0.989 -_- ' -_ : -- --1.59 _ 27.69 - -- --- -- - - - 0.00 --- __+ : 27 --- _. _ - 6 - - -- _166 -- - - --0 - - - _.69 - - 0 -- - --0 -- ---- - - - i_ i - - - -- - - --- - -- -- -- 6 c) AED excursion -20 .6 Envelope loss/gain 550 301 109 97 12 a) Infiltration 98 26 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6'to 13) 648 327 109 97 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 648 327 109 97 15 Duct loads 24% 40% 158 131 24% 40°/a 27 39 Total room load 806 458 136 -135 Air required (cfm) 42 21 7 6 I&K_FP_enrrlghtsoft' Right -Suite® Universal 2015 15.0.18 RSU06057 ...ot23TarponFlatsAGL\Lot23TarponFlatsModelAGL.rup Calc=W8 Housefaces: E U - + wrightsoft, Right-M Worksheet Entire House DEL -AIR HEATING & AIR CONDITIONING 531 CODISCOWAY, SANFORD,FL32771 Phone:407-333-2665 Fax:407-333-3853 Web:WWW.DEL-AIR.COM Job: Lot23TarponF1atsModelAGLW Date: 01.18.14 By: ER 1 Room name ms bth great rm 2 Exposed wall 13.0 ft 24.5 ft 3 Room height 19.3 It heat/cool 9.3 ft heat/cool 4 5 Room dimensions Roam area 1 1.0 x 167.3 ft 167.3 ftz 1.0 x 5125 ft 512.5 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ft) Load number, (Stuh/ftz°F) (Btuh/ftg or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A 2ocs. _ - 0.201 n 5:63 4.00 1121 95 533 378 '- - - 0 - - 0 - - 0 - - 0 2A 2om 2A-2om 0.270 - --- 0.270- n n 7.56 -- - -7.56 8.24 8.24 . 0 ;-- -- - 27 0 0 0 202 ' 0 - - 220 0 - ____0 0 . _ _ _ _ 0 0' -- ----- 0 0 -- - -0 11 -- - 13A-2ocs 10C-m 0.201 0.270 a a 5.63 7.56 4.00 10.27 0 0 0 0 0 0 0 0 61 24 27 19 150 181 107 247 2A-2om 2A-2om 0.270 0.270 a ' e 7.56 7.56 14.68 20.42 0 0 0 0 0 0 0 0 10 0 8 0 76 0 147 0 2A-2om 0.270 a 7.56 21.52 0 0 0 0 0 0 0 0 2A-2om- -----_0.270-e_ 7.56 -22.39 0 - '0. -0 -0 ----0 --- 0 ------- 0--------0 - 13A-2ocs_ 0.201 s: 5.63 4.00 .0 0 - 0_ 0 0 0 0 0 10C-m: 0.270 s 7.56 6.94 0 0 0 0° 0- 0 0 0 F-G u-_ G 2A 2om 0.270.-s- - 756 _ _ . 8;24 0 -0 - 0 - -0 - 01 0 - __.0- - --0 _ - 13A-2ocs 0.201 w 5.63 4.00 0 0 0 0 168 72 405 288 2A-2om 0.270 w 7.56 22.36 0 0 0 0 0 0 0 0 2A-2om 0.270 w 7.56 22.36 0 0 0 0 0 0 0 0 2A-2om 0.270 w 7.56 22.36 0 0 0 0 0 0 0 0 _ - 0.270 w- 7.56 - 9.92 0_ 0 _ _ 0 0 _ - _ _ 96 _ _- _ 96 726 - _ 952 P .2A-2omd- __ _ 1213-0sw _ _ _ 0.097 2.72 _ 1.57 _ A 0 _ 0 0 0 0 0 - 0 0 _11 bo _-- - -0.390 -n-- : 10.92 _11.31. 0 _0 _- _ 0 -- -0 - _ _0___ _ ___0 --- --0___.__0 C 16X19-bad _0.408 =_ - 1.59 1.49 _ 167 167 265 _ _ - 249 _ - _513 _ _513 _ 813 _ _ _ 762 F _ 22A tpl _- - - - --- __0.989 - --- z - _ - _ 27.69 - ---- _ _ 0:00 - --- - _ -_ 167. t` .i _ 13 360 - _ 0 - . _ 513 -- __ -25 - - - _ _ 678: - _ _ _ 0 6 c) AED excursion -51 1486 Envelope loss/gain 1359 796 3029 3988 12 a) Infiltration 213 57 402 108 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 4 920 Appliances/other 0 0 Subtotal (lines 6 to 13) 1573 853 1 3431 5016 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0, 14 Subtotal 1573 853 3431 5016 15 Duct loads 24% 401% 384 341 24% 40% 837 2007 Total room load 1956 1194 4267 7023 Air required (cfm) 102 55 222 321 Calculations aooroved bvACCA -` f-'- wtriightsoit- Right -Suite® Universal 201515.0.18 RSU08057 ACCK...ot23TarponRatsAGULot23TarponFlatsModelAGL.rup Calc=W8 Housefaces: E of Manual J 3 -rF wrlghtsoft° Right-JO Worksheet Entire. House DEL -AIR HEATING & AIR , CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web: W,WW.DEL-AIR.COM Job: Lot23TarponF1atsModelAGLW Date: 01.18.14 By: ER 1 Room name nook bdrm 3 2 3 Exposed wall Room height 17.5 it 9.3 ft heat/cool 28.0 ft 9.3 ft heat/cool 4 5 Room dimensions Room area 11.0 x 11.5 ft 126.5 ft2 1.0 x 205.8 ft 205.8 ft2 Ty Construction U-value Or HTM Area (ft� Load Area (W) Load number (Btuh/ftl-°F) (Btuh/ft� or perimeter (it) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cocl Gross N/P/S Heat Cool 6 - 13A-2ocs 2A 2om _ M-2om-- - 0:201 0.270 - n n ; n --.-- 5:63 7.56 7_56, - 4.00 8.24 8°24 - 0 0 - i 0 0 0 .- '- 0 - - 0 0 - - ___0 - 0 0 -0 0 0 0_ 0 0 -0 0 0 - 0 0 0 - - 0 11 - - 13A-2ocs 10C-m - -b.270 0.201 .0.270 a a - 5.63 7.56 4.00 10.27 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2A-2om 2A-2om 2A-2om 0.270 0.270 0.270 a a a 7.56 7.56 7.56 14.68 20.42 21.52 ' 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2A-2om--- _------ 13A-2ocs 0.270 0.201 a s _._--7.56.__22.39 5.63 4.00 _0__ 61- _-00 61 341 -_-__0 243 _--____0 126 126 709 504 10C-m 2A-2om- 13A-2ocs 0.270 :0.270 0.201 s . s w 7.56 _ -7.56 5.63 6.94 --- 8.24 4.00 0 - 0 103 0 _ -0 52 0 0 292 0 -0 208 0 - - 0 135 0 ---0.--. 102 0 0 571 0 - 0 406 w 2A-2om 2A-2om 0.270 0.270 w w 7.56 7.56 22.36 22.36 51 0 11 0 383 0 1133 0 0 0 0 0 0 0 0 0 2A-2om 2A-2omd 1213-0sw 0.270 ----0.270 '0.097 w _ w_ - 7.56 _._7.56_ - 2:72 22.36 _ 9:92 1.57 0 - Q 0 0 - 0 0_ 0 - - 0 0 0 ____0 0 34 --- -- -Q 37 7 . -- -0 37 255 - -0 101 755 - - - 0 59 -- - P --D:-11D0 =. -- -- 16X19-0ad -- 0.390 _n _ _- 10l92 1.59 ___11.31 1 49 -0 _ 127 _ -'__0 127 _0_-- - _ _ 201 ___.0 -_ _ 188 -0 _ _ 206 --_-_0 _ _ 206 _.-- 0-----__0 ____326 _ 306 C _ _ F . _ - - -----=- _ 22A;tpl _. --- -- ---- _ _ _0.408 _ 0.989 - -- _ _ r_ ---- - _ _27.69 _-_._- _ _ _ 0.00 . _ 127 - _ _ 18 - __ . 485 _ -_0 -----_-206 -- _-- 28 . _ _ _775 - -- _ 0 - - --- --- -- A. -- 6 c) AED excursion I 787 473 Envelope loss/gain 1702 25.59 2738 2503 12 a) Infiltration 287 77 459 123 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1989 2636 3198 2626 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1989 2636 3198 2626 15 Duct loads 124 % 40 % 485 1055 24 % 40 % 780 1051 Total room load 2474 36901 3978 3676 Air required (cfm) 129 1691 207 168 Calculations rACCA to meet all requirements of Manual J_ wrightsaf t- Right -Suite® Universal 2015 15.0.18 RSU08d57 ot23TarponRatsAGL\ ot23TarponRatsModelAGL.rup Calc=MJ8 Housefaces: E I 4 - } - wrightsoft' Right-M Worksheet Entire House DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web: W W W.DEL-AIR.COM Job: Lot23TarponF1atsModelAGLW Date: 01.18.14 By: ER 1 Room name I bth 2 kitchen 2 Exposed wall 1 6.0 ft 0 ft 3 Room height ,9.3 ft heat/cool 9.3 ft heat/cool 4 5 Room dimensions Room area j 10.6 x 6.0 ft 63.5 ft' 11.0 x 14.5 ft 159.5 ftz Ty Construction number U-value (Btuh/ftz°F) Or HTM (Btuhfftz) Area I (m or perimeter (ft) i Load (Btuh) Area (M or perimeter (ft) Load (Btuh) Heat Cool Gross I N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A 2ocs 0.201 n 5.63 4.00 0- 0 0 0 0 A - 0 0 2A 2om, 2A-2om- = - 0.270 0.270 n n 7.56 7.56 .8.24 8.24 "0 - 01 0 ---0 0 - -'- 9 0 : - - - 0 0 0 0 0 -0 11 13A-2ocs 1OC-m 0.201 0.270 a a 5.63 7.56 _ _ 4.00 10.27 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2A-2om 2A-2om 2A-2om 0.270 0.270 0.270 a e. a 7.56 7.56 7.56 14.68 20:42 21.52 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -2A-2om------ - - - 13A-2ocs , -- - 0.270 0.201 _e_ s 7.56 5.63 - ._22.39 4.00 = 0 56 - --0 50 - ,- - -0 279 - - - 0 199 - - - 0__ 0 ____0__ 0 -0 0 - 0 0 - - 10C-m 2A-2orn -- - 13A-2ocs 0:270 -----0.270 0.201 s -S- w 7:56 ---7.56:- 5.63 -. 6.94 - 8.24 4.00 0 _ -6 0 0. -- 6 0 0 _-°48 0 0 -'- - 52•-- 0 0 ---0 0 0 ------ 0 0 0 - ----- 0:- 0 0 -- -0 0 2A-2om 2A-2om 0.270 0.270 w w 7.56 7.56 22.36 22.36 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2A-2om 2A-2omd_-- -- _ 1.2B-Osw 0.270 0.270 0.097::- w -w- 7.56 _ - - 7 56 2.72' 22.36 _ -- 9.92 1.57 0 -- -0 131 0 _.-- _ - 0 131 0 _ ____0 - 355 0 -- --- 0_____ 205 0 -0 107 0 _ --- -0 107 0 ---- _0 291 0 _ _ --0 169 _--- P- �D C 1.100 -'--- - - _ - 16X19-Oad - - - -0.390 -n _ __ _ _ 10:92 1.59 _ _ 11'.31 _ _ _ 1.49 -- ` -0 _ - 63 ° -- --0'-- . -63-- _____0 __ _ 100 ---- --_0 _94. --- ----- 0 __.___160 -- - -"-0 _ _ __ 160 - __0 _ - 253 --- ---0 237 _ _ _ 22A-tpl __ _ :.-- _ _ _ _0.408 - -- •0.989 - _ _r_ _.:. _. -27.69 _ _0.00 • 63 i . -- -- --' 6 166 . _ -- 0 ---___160 -- - 0 -- -- __0._ -- - 0 6 c) AED excursion j -32 -90 Envelope loss/gain 948 517 544 315 12 a) Infiltration 98 26 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Qa 230 0 0 0 0 Appliances/other 0 1200 Subtotal (lines 6 to 13) 1047 544 544 1515' Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1047 544 544 1515 15 Duct loads 1 249/6 1 40% 255 218 24% 40% 133 606 Total room load 1302 761 677 2121 Air required (cfm) 68 35 35 97 �4f,- wrightsof - CP. Right -Suite® Universal 201515.0.18 RSU08057 ...ot23TarponFlatsAGL\Lot23TarponFlatsModelAGL.rup Calc=WB Housefaces: E 5 -rF wrightso>ft° Right-M Worksheet Entire House DEL -AIR HEATING & AIR , CONDITIONING 531CODISCOWAY, SANFORD,FL32771 Phone:407-333-2665 Fax:407-333-3853 Web:WWW.DEL-AIR.COM Job: Lot23TarponFlatsModelAGLW Date: 01.18.14 By: ER 1 Room name utility bdrm 2 2 Exposed wall 6.5 ft 27.0 ft 3 Room height 19.3 ft heat/cool 9.3 ft heat/cool 4 Room dimensions 1.0 x 52.5 ft 1.0 x 182.5 ft 5 Room area 52.5 ftz 182.5 ftz Ty Construction U-value Or HTM Area I (ft� Load Area (ft2) Load number (BtuWft'-OF) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A 2ocs 0201 n 5.63 --- 4.00 ? 0 0 0 0 - - : 135 135 761 541 2A-2om 0.270 n 7.56 8.24 0 0 0 0 0 0 0 -0 _2A-2om 0.270 n7;56 - 8 24 0 - - 0 - 0 -0 - -- -0 __ 0 - - --0 - 0 _ 13A-2ocs 0.201 a 5.63 4.00 - 1 61 52 294 209 117 86 482 342 11 1OC-m 0.270 a 7.56 10.27 10 0 0 0 0 0 0 0 2A-2om 0.270 a 7.56 14.68 0 0 0 0 0 0 0 0 2A-2om 0.270 a 7.56 20.42 8 3 63 170 0 0 0 0 2A-2om 0.270 a 7.56 21.52 0 0 0 0 31 8 234 667 2A-2om 0.270 a 22.39 0 --_0 - - --0 ---_ 0 _0 - - 0 - --0 - - - 13A-2ocs - 0.201 s ____7.56 5.63 -. _ . 4.00 0 `` 0 0 0 0 0 0 0 1OC-m 0.270 s 7.56 6.94 0 0 0 0 0 0 0 0 2A-2om - s 7.56 _ - 8.24 --- 0 ____0 0 - = 0__ -0 - _0 -0 0 -- 13A-2ocs --0.270- 0.201 w 5.63 4.00 0 0 0 0 0 0 0 0 2A-2om 0.270 w 7.56 22.36 0 0 0 0 0 0 0 0 2A-2om 0.270 w 7.56 22.36 0 0 0 0 0 0 0 0 2A-2om 0.270 w 7.56 22.36 0 0 0 0 0 0 0 0 2A-2omd 0.270 w-- 7.56 . 9.92 0 ._. - 0 0 - - __0__ _____0 _0 - 0 - - 0 - - P ._.. 12B-0sw 0.097 - - 2.72 _ 1.57 65 43 116 67 : 0 _ 0 0 0 L-D 11 D0 . __ __ 0.390 _n. , . - _10:92 11.31 _ _ 23 _ 23 248 - _ __256 ' -- -0 _ _ -0 _.-.._._ --0 - _ _- - 0 C 16X19.Oad 0.408 _ 1.59 1.49 53 _ _ _ 53 83 78 1_83 _ _ _ _ 183 _ 289. 271 _ _ _F _ _ _ _ 22A-tpl .'- - - _ 0 989 _ - _ - .--27.69 _ _ _ - --- 0.00 . -- 53 - - . - 7 - - - 180 .-_ -- 0 - - 183 - -=27 - .. _- .748 .__ -:: 0 6 c) AED excursion -44 62 Envelope loss/gain 984 737 2515 1884 12 a) Infiltration 107 29 443 119 b) Room ventilation 1 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 600 0 Subtotal (lines 6 to 13) 1091 1366 2958 2003 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1091 1366 2958 2003 15 Duct loads 241% 40% 266 547 24% 40% 721 801 Total room load 1357 • 1912 3679 2804 Air required (cfm) 71 87 192 128 ACCA to meet all reauirements of Manual J -t'N- wrlightsoft- Right -Suite® Universal 2015 15.0.18 RSU08657 MCP...ot23TarponFlatsAGLlLot23TarponFlatsModelAGL.rup CaIc=MJ8 House faces: E + wrightsoft, Right-M Worksheet Entire House. DEL -AIR HEATING & AIR CONDITIONING 531 CODISCOWAY, SANFORD,FL32771 Phone:407-333-2665 Fax:407-333-3853 Web:WWW.DEL-AIR.COM Job: Lot23TarponFlatsModeIAGLW Date: 01.16.14 By: ER 1 Room name derdbdrm 4 bth 3 2 3 Exposed wall Room height 18.0 ft 9.3 ft heat/cool 0 ft 9.3 ft heat/cool 4 5 Room dimensions Room area 1 12.0 x 12.5 ft 150.0 ftz 10.0 x 5.5 ft 55.0 ftz Ty Construction number U-value (Btuh/ftZ°F) Or HTM (Btuh/ft2) Area I (ftz) or perimeter (ft) Load (Btuh) Area (ft9 or perimeter (ft) Load (Stuh) Heat Cool Gross NOS Heat Cool Gross N/P/S Heat Cool 6 Uhl 13A-2ocs _ 2A-2om 2A-2om = am 0.270 0.270 n n n 5.63 7.56 _Z_56. 4.00 8:24 { 0 �' -0, -0 0 0 -0-- 0 0 ___0__ 0 0 -0 0 0 0 0 0 - - 0' 0' 0 - -0 0 0 -- __0 II�_G 11 - -- 13A-2ocs 10C-m 2A-2om 2A-2om 2A-2om 2A-2om- - - 13A-2ocs 10C-m 0.201 0.270 0.270 0.270 0.270 0.270 0.201 0.270 a a a a a -e- s . s 5.63 7.56 7.56 7.56 7.56 --7.56 5.63 7:56 _ -8.24 4.00 10.27 14.68 20.42 21.52 __22.39 4.00 6.94 - - - 112 0 0 0 10 --31 56 0 81 0 0 0 0 --6 _ 56 0 456 0 0 0 0 --_234__-- 315 0 324 0 0 0 0 69-4 224' 0 0 0 0 0 0 - _.0 0 0 0 0 0 0 0 0 = 0 0' 0 0 0 0 0 ---0 -0 0, 0 0 0 0 0 0 0 0 -- 2A 2om = -- -- - 13A-2ocs 2A-2om 2A-2om 2A-2om 2A-2omd 12B-0sw 0.270 0.201 0.270 0.270 0.270 _0.270 0.097 s w w w w w_ - - 7.56 5.63 7.56 7.56 7.56 _7.56 2.72 _ 8.24 4.00 22.36 22.36 22.36 _9.92 1.57 , - 0 0 0 0 0 _0 0 - 0 0 0 0 0 0 0 - - .. -0 0 0 0 0 0- 0 >- - 0 0 0 0 0 _ _ 0 0 _ 0 0 0 0 0 __-- -__0 0 . 0 0 0 0 0 _ _ 9 0 -0 0 0. 0 0 _ _ _0 0 - 0 0 0 0 0 -- - 0. 0 P L--D .11D0_ _ _ _ 16X19-0ad 0390 0.408 n-' = _10.92 1_.59 _11.31 1.49 -- - -0'----- 150 _--0 _ _ 150 0 _ _ - 238. -- __0 _ _ 223 -- --0.---- . _ _ 55, - _0 _ - - _ -55 - -0 _ 87 -- --0 .___ 82 _ C F _ _ - _ _ 22A-tp1 _ _ __ 0.989 _ .. _ ___-2T69 _ _. 0.00 _ -. t 150 _ _ ..18 _ -___ _ 498 - _ __0 _ -- 55 _ _ -0 -- -.0, -.0. _ _ 0 6 c) AED excursion I 93 -5 Envelope loss/gain 1741 1557 87 77 12 a) Infiltration 295 79 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 I 0 0 0 0 0 Subtotal (lines 6 to 13) 2037 1636 87 77I Less external load 0 0 0 0 Less transfer. 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2037 1636 87 77 15 Duct loads 24% 40% 497 655 24% 40% 21 31 Total room load 2533 2291 1o8 108 Air required (cfm) 132 105 6 5 Calculations wDroved by AC -'I - wrightsafi Right-Suite®Universal 201515.0.iBRSU08057 ��P...ot23TarponFlatsAGL\Lot23TarponFlatsModelAGL.rup Calc=MJB Housefaces: E rwrightsoft® Duct System Summary Entire House DEL -AIR HEATING &AIR. CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web: W W W.DEL-AIR.COM For: Phoenix Realty Homes Inc FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.30 in H2O 01.06 in H2O 0.24 in H2O 0.120 / 0.120 in H2O 0.134 in/100ft 1533 cfm Job: LoU2 TarponFlatsModel... Date: 01.18.14 By: ER Cooling 0.30 in H2O 0.06 in H2O 0.24 in H2O 0.120 / 0.120 in H2O 0.134 in/100ft 1533 cfm 179 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design Fl� Diam (in) H x W (in) Duct Matl Actual Ln (ft) Fig.Egv. Ln (ft) Trunk bdrm 2 h 3679 192 128 i 0.157 8.0 Ox 0 VIFx 53.0 100.0 st2 bdrm3 h 3978 207 168 0.21 6 8.0 Ox 0 VIFx 25.9 85.0 sti loth 2 h 1302 68 35 0.213 5.0 Ox 0 VIFx 27.7 85:0 st1 loth 3 h 108 6 5 0.172 4.0 Ox 0 VIFx 39.4 100.0 st2 den/bdrm4 h 2533 132 105 0.166 7.0 Ox 0 VIFx 44.9 100.0 st2 greatrm C 3511 111 161 0.183 8.0 Ox 0 VIFx 31.1 100.0 st2 greatrm-A c 3511 111 161 0.1176 8.0 Ox0 VIFx 36.0 100.0 st2 Idtchen C 2121 35 97 0.232 6.0 Ox0 VIFx 18.5 85.0 st1 msbdrm C 3678 161 168 0.135 8.0 Ox0 VIFx 63.1 115.0 st3 msbdrm-A c 36' 8 161 168 0.1I34 8.0 Ox0 VIFx 63.7 115.0 st3 msbth h 1956 102 55 0.142 6.0 Ox0 VIFX 53.5 115.0 st3 nook c 3690 129 169 0.214 8.0 Ox 0 VIFx 27.2 85.0 sti utility C 1912 71 87 0.218 6.0 Ox 0 VIFx 25.2 85.0 sti We h 806 42 21 0.1138 4.0 Ox 0 VIFx 58.9 115.0 st3 WIC h 136 7 6 1 0.142 4.0 Ox0 VIFx 53.9 115.0 st3. Trunk Htg CIg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR �. (fpm) (in) (in) Material Trunk st3 Peak AVF 472 418 0.134 601 12.0 0 x 0 VinIFIX st2 st2 Peak AVF 1023 977 0.134 I 579 18.0 0 x 0 VinlFlx sti sti Peak AVF 1533 1533 0.134 j 703 20.0 0 x 0 VinlFlx •_":'µ" ri hts®ftg o, zq,13s22s w � Right -Suite® Universal 201515.0.18 RSU08057 P , ACCA...ot23TarponRatsAGL\Lot23TarponFlatsModelAGL.rup Calc=W8 House faces: E I � Name Grill Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rbi Ox 0 1533 1533 0 0 0 0 Ox 0 VIFx wrlght5®ftx Right -Suite@ Universal 201515.0.18 RSU08057 ACCK...ot23TarponRatsAGL\Lot23TarponFlatsModelAGL.rup Calc=MJB Housefaces: E FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94' The lower the EnergyPerformance Index, the more efficient the home. I 3915 DUNESIDE U�IVE, Fort Pierce, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1787.30 ft2 b. Frame - Wood, Adjacent R=11.0 340.67 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2048.00 ft2 6. Conditioned floor area (ft2) 2048 b. N/A R= ft2 c. N/A R= ft2 7. Windows- Description Area 11. Ducts R ft2 a. U-Factor: Dbl, U=0.27 416.55 ft2 a. Sup: Attic, Ret: Attic, AH:.Attic 6 409.6 SHGC:. SHGC=0.28 b. U-Factor: N/A ft2 SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 46.0 SEER:14.00 SHGC: d. U-Factor: N/A ft2 13. Heating systems l kBtu/hr Efficiency. SHGC: a. Electric Heat Pump 46.0 HSPF:8.20 Area Weighted Average Overhang Depth: 5.995 ft. Area Weighted Average SHGC: 0.280 8. Floor Types Insulation. Area 14. Hot water systems Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 2048.00 ft2 a. Electric EF: 2.4 b. N/A R= ft2 c. N/A R= ft2 b. Conservation features None 15. Credits i Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: I Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 11/23/2015 8:52 AM EnergyGauge® USA - FlaRes20,14 - Section R405.4.1 Compliant Software • f COi FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot23TarponFlats ModeIAGLW Builder Name: Phoenix Realty Homes Inc Street: 3915 DUNESIDE DRIVE Permit Office: City, State, Zip: Fort Pierce , FL ; Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (2128.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1787.30 ftZ b. Frame - Wood, Adjacent R=11.0 340.67 ftZ 3. Number of units, if multiple family 1 c. N/A R= ftZ 4. Number of Bedrooms 4 d. N/A R= ftZ 10. Ceiling Types (2048.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2048,00 ftZ 6. Conditioned floor area above grade (ftZ) 2048 b. N/A R= ft2 Conditioned floor area below grade (ftZ) 0 c. N/A R= ftZ 11. Ducts R ftZ 7. Windows(416.5 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 409.6 a. 0-Factor: Dbl, U=0.27 416.55 ftZ SHGC: SHGC=0.28 b. U-Factor: N/A ftZ 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 46.0 SEER:14.00 c. U-Factor: N/A ftZ SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftZ a. Electric Heat Pump 46.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 5.995 ft. Area Weighted Average SHGC: 0.280 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2048.0 sqft.) Insulation Area EF: 2.400 a. Slab -On -Grade Edge Insulation R=0.0 2048.00 ftZ b. Conservation features b. N/A _ R=. ftZ None c. N/A R= ftZ 15. Credits Pstat Total Proposed ModifiqIId Loads: 56.99 Glass/Floor Area: 0.203 - c L+ /'-'��7�7 PASS Total Baseline: Loads: 60.43 S' I hereby certify that the plans and specifications covered by Review of the plans and gSIaE this calculation are in compliance with the Florida Energy Code. specifications covered by this calculation indicates compliance O �` f,,;°'� �,•�l, rs+ with the Florida Energy Code. 'rrrrs`` w o PREPARED BY: �� "a Before construction is completed ` .Q DATE: 11_93_1r, 1 this building will be inspected for compliance with Section 553.908 . I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. OWNER/AGENT: BUILDING OFFICIAL: DATE: f DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosur ualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402. velope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming u get o N tested jn accordance with Section 803 of RESNET Standards, is not greater than 0.050 Qn for whole hou 11/23/2015 8:52 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 13677iIZtWW11E,I PROJECT Title: Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot23TarponFlatsModelAGL User 1 Phoenix Realty Homes Inc Single-family New (From Plans) Bedrooms: Conditioned Area Total Stories: Worst Case: Rotate Angle: Cross Ventilation: Whole House Fa 4 2048 1 No 0 No No Address Type: Street Address Lot # 23 Block/SubDivision: Tarpon Flats PlatBook: Street: 3915 DUNESIDE DRIV County: St. Lucie City, State, Zip: Fort Pierce , FL , CLIMATE I Design Location TMY Site IECC Zone Design Temp 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ST_LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Blockl 2048 19046.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished ' Cooled Heated 1 Main 2048 19046.4 Yes 5 4 1 Yes- Yes Yes FLOORS I # Floor Type Space Perimeter I R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 191.5 ft i 2048 ftz ---- 0.35 0 0.65 ROOF / V # Type Materials Roof Gable Roof Area Area Color Solar Absor. SA Emitt Tested Emitt Deck Pitch Tested Insul. (deg) 1 Gable or Shed Metal 2290 ft' 512 ftz Medium I 0.65 N 0.65 No 20 26.6 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2048 ftz N N CEILING i # Ceiling Type Space R--Value Area Framing Frac Truss Type 1 Under Attic (Unvented) Main .0 2048 I ftZ 0.11 Wood a 11/23/2015 8:52 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 FORM R4(l5-9f114 WALLS Adjacent Cavity) Width Height Sheathing Framing Solar Below Space - 1 S Exterior Concrete Block - Int Insul Main 4.1 43 6 9 4 406.0 ft2 0 0 0.6 0 2 W Exterior Concrete Block - Int Insul Main 4.1 60 0 9 4 560.0 ft2 0 0 0.6 0 3 N Exterior Concrete Block - Int Insul Main 4.1 50 6 9 4 471.3 ft2 0 0 0.6 0 _ 4 E Exterior Concrete Block - Int Insul Main 4.1 37 6 9 4 350.0 ft2 0 0 0.6 0 5 - Garage Frame - Wood Main 11 36 6 9 4 340.7 ft2 0 0.23 0.01 0 DOORS # Ornt - Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 - Wood Main ! None I .39 2 10 8 22.7 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. v Wall Overhang # Ornt ID Frame Panes NFRC U-Factor, SHGC Area Depth Separation Int Shade Screening 1 S 1 Metal Low-E Double Yes 0.27 0.28 20.0 ft2 18 ft 8 in 0 ft 3 in None None 2 S 1 Metal Low-E Double Yes 0.27 0.28 6.3 ft2 2 ft 0 in 0 ft 4 in Drapes/blinds None 3 W 2 Metal Low-E Double Yes 0.27 0.28 84.4 ft2 2 ft 0 in 0 ft 4 in Drapes/blinds None 4 W 2 Metal Low-E Double Yes 0.27 0.28 31.7 ft2 2 ft 0 in 0 ft 4 in Drapes/blinds None 5 W 2 Metal Low-E Double Yes 0.27 0.28 33.8 ft2 2 ft 0 in 0 ft 4 in Drapes/blinds None 6 W 2 Metal Low-E Double Yes 0.27 0.28 96.0 ft2 13 ft 0 in 0 ft 3 in None None 7 N 3 Metal Low-E Double Yes 0.27 ! 0.28 13.3 ft2 2 ft 0 in 0 ft 4 in Drapes/blinds None • 8 N 3 Metal Low-E Double Yes 0.27 0.28 26.7 ft2 2 ft 0 in 0 ft 4 in Drapes/blinds None 9 E 4 Metal Low-E Double Yes 0.27 ! 0.28 24.0 ft2 9 ft 2 in 1 ft 5 in None None 10 E 4 Metal Low-E Double Yes 0.27 0.28 10.0 ft2 9 ft 2 in 1 ft 5 in None None 11 E 4 Metal Low-E Double Yes 0.27 0.28 8.3 ft2 2 ft 0 in 0 ft 4 in Drapes/blinds None 12 E 4 Metal Low-E Double Yes 0.27 0.28 31.0 ft2 2 ft 0 in 0 ft 4 in Drapes/blinds None 13 E 4 Metal Low-E Double Yes 0.27 0.28 31.0 ft2 3 ft 0 in 1 ft 5 in Drapes/blinds None GARAGE I # Floor Area Ceiling Area ExposedlWall Perimeter Avg. Wall Height Exposed Wall Insulation 1 525 ft2 384 ft2 l64 ft 9.3 ft 1 INFILTRATION I # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000295 1587.2 i 87.14 I 163.87 .2157 5 D � � 11/23/2015 8:52 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-201.4 HEATING SYSTEM I # System Type Subtype I Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.2 46 kBtu/hr 1 sys#1 COOLING I SYSTEM # System Type Subtype I Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 14 46 kBtu/hr cfm 0.75 1 sys#1 HOT WATER I SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Heat Pump Garage 2.4 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS ---- Supply ---- ---- Return ---- - Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat' Cool 1 Attic 6 409.6 ft Attic 102.4 ft Proposed Qn Attic --- cfm 102.4 cfm 0.05 0.60 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling[ Heatin[X] ] Jan [[ �I Feb Jan W Feb [[ jj Mar [X] Mar [ j Apr [ ] Apr May X May Jun X Jul Jun Jul Auf rj Aug Se Sep [ ] [ ] Oct Oct [[ jj Nov [X] Nov [[ ]] Dec [X] Dec Ventin [ ] Jan [ ] Feb X Mar [X] A r [ l Ma [ l Jun [ Jul l Aug [ Se [X] Oct [[X]] Nov [[ ]] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 i78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 , 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 i I 1! /23/2015 8:52 AM EnergyGauge® USA-* FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 i FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Form R405 Duct Leakage Test Report rerfurrnarllce IVIeLnUU Project Name: Lot23Tarpon Flats ModelAGLW Builder Name: Phoenix Realty Homes Inc Street: Permit Office: City, State, Zip: Fort Pierce , FL, Permit Number: Design Location: FL, Fort Pierce I Jurisdiction: Duct Test Time: Post Construction I Duct Leakaqe TesIt Results - CFM25 Duct Leakage Test Values Line System Out Iside Duct Leakage 1 System 1 I cfm25(Out) 2 System 2 i cfm25(Out) 3 System 3 i cfm25(Out) 4 System 4 cfm25(Out) 5 Total House Duct System Leakage Sum lines 1-4 Divide by (Total Conditioned Floor Area) _ (Qn,Out) I I I hereby certify that the above duct testing performance results demonstrate compliance with the Florida Energy Code requirements in accordance with Section R403.2.2. SIGNATURE: PRINTED NAME: DATE: Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by an energy rater certified in accordance with Section 553.99, Florida Statutes. BUILDING OFFICIAL: DATE: 11/20/2015 1:47 PM EnergyGaugeO USA - FlaRes2014 - Section R405.4.1 Compliant S Page 1 of 1 FORM R405-2014 RESIDENTIAL ENERGY CONSERVA Florida Department of Bc Simulated Performance Applications for compliance with the 2014 Florida residential Simulated Performance method shall h ❑ This checklist CODE DOCUMENTATION CHECKLIST and Professional Regulation tive (Performance) Method . ling Code, Energy Conservation via the ❑ A Form R405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page - indicating home address, a -ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst -case orientation, name and version of the compliance software tool, name of individual completing the compliance report (1 page) and an input summary -checklist that can be used for field verification (usually 4 pages/may be greater). ❑ Energy Performance Level (EPQ Display Card (one page) ❑ Mandatory Requirements(three pages) Required prior to CO for the Performance ❑ Air Barrier and Insulation Inspection Compol ent Criteria checklist (Table R402.4.1.1 - one page) ❑ A completed Envelope Leakage Test Repo i( usual)Y one page) ❑ If Form R405 duct leakage type indicates al iything other than "default leakage", then a completed Form R405 Duct Leakage Test Report (usually one page) i i I. i I D D � 11/20/2015 1:44:13 PM EnergyGaugel0 - USRCSB v4.0 ll r Page 1of 1