HomeMy WebLinkAboutENERGY EFFICIENCY CODER !,
FORM R405-2017
FLORIDA ENERGY EFFICIENC I CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
•a
Project Name: 9632 Enclave Circle I
Builder Name:
Street: 9632 Enclave Circle SCANN , D
Permit Office: St Lucie
City, State, Zip: Port St Lucie, FL , 34986 BY
Mayrides
Permit Number:
Jurisdiction: 612000
Owner: Tom & Mini
St Lucie C unty
d%
County: St. LucienteaCOOV
Design Location: FL, Fort Pierce
1. New construction or existing New (From Plans)
9. Wall Types (4977.2 sqft.)
Insulation Area
a. Concrete Block - Int Insul, Exterior
R=5.0 4492.20 ft2
2. Single family or multiple family Single-family
b. Frame - Wood, Adjacent
R=13.0 485.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 5
d. N/A
10. Ceiling Types (7150.0 sqft.)
R= ft2
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=20.0 7150.00 ft2
6. Conditioned floor area above grade (ft2) 7150
b. N/A
R= ft2
c. N/A
R= ft
Conditioned floor area below grade (ft2) 0
11. Ducts
R ft2
7. Windows(935.8 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Garage
6 420
6 500
a. U-Factor: Dbl, U=0.33 388.67 ft2
b. Sup: Attic, Ret: Attic, AH: Garage
6 476.66
SHGC: SHGC=0.21
c. Sup: Attic, Ret: Attic, AH: Garage
b. U-Factor: Dbl, U=0.27 240.00 ft2
12. Cooling systems
a. Central Unit
kBtu/hr Efficiency
36.4 SEER:17.00
SHGC: SHGC=0.25
b. Central Unit
48.5 SEER:16.00
c. U-Factor: Dbl, U=0.30 161.83 ft2
c. Central Unit
25.6 SEER:17.00
SHGC: SHGC=0.21
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 145.33 ft2
a. Electric Strip Heat
36.0 COP:1.00
SHGC: other (see details)
b. Electric Strip Heat
c. Electric Strip Heat
34.0 COP:1.00
26.0 COP:1.00
Area Weighted Average Overhang Depth: 9.520 ft.
Area Weighted Average SHGC: 0.224
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (7150.0 sqft.) Insulation Area
EF: 0.920
a. Slab -On -Grade Edge Insulation R=0.0 7150.00 ft2
b. Conservation features
b. N/A R= ftz
None
c. N/A R= ft2
15. Credits
Pstat
Total Proposed Modifi d Loads: 199.84
����
Glass/Floor Area: 0.131 Total Baselin I
Loads: 208.48
HSrAr�
I hereby certify that the plans and specifications covered by
Review of the plans and
Di;
this calculation are in compliance with the Florida Ene
specifications covered by this
111 0*6
Code.
calculation indicates compliance
with the Florida Energy Code
OVA"
0
PREPARED BY: I
Before construction is completed
DATE: 21
this building will be inspected for
compliance with Section 553.908
0 n. v,
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Co
,Co0 WE,4
OWNE G
BUILDING OFFICIAL:
DATE: S--
DATE:
I
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
5/212019 3:44 PM EnergyGauge® USA 6.0.02 (Rev.1) - FlaRes20'11 FBC 6th Edition (2017) Compliant Software Page 1 of,.5
��r�RA'—nGpnnA7 IA1b11T 01 I11AMAD I t'%WCf%W1 ICT RIFP(1RT
F%it\IVI
-- -- - --
- - - -
PROJECT
Title: '
9632 Enclave Circle
Bedrooms: 5
Address Type:
Street Address
Building Type:
User
Conditioned Area: 7150
Lot #
Owner Name:
Tom & Mini Mayrides
Total Stories: 1
Block/Subdivision:
# of Units.
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
9632 Enclave Circle
Permit Office:
St Lucie
Cross Ventilation:
County:
St. Lucie
Jurisdiction:
612000
Whole Hoi se Fan:
City, State, Zip:
Port St Lucie ,
Family Type:
Single-family
FL, 34986
New/Existing:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
Design Location
TMY Site 97.5 % 2.5 %
FL, Fort Pierce FL VERO_BEACH_MUNI I 39 90
70
75 299
62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
2543 25430I
2
Block2
3107 45051.,
3
Block3
1500 15000
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
Main 1
2543 25430 No 4
4
1 Yes
Yes Yes
2
Main 2
3107 45051.5 Yes 0
0
1 Yes
Yes Yes
3
Main 3
1500 15000 No 2
1
1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio
Main 1 189.8 1I 0
2543 ftz
-_-_
0 0 1
2 Slab -On -Grade Edge Insulatio
Main 2 128 ftI 0
3107 ftz
0 0 1
3 Slab -On -Grade Edge Insulatio
Main 3 137 f i 0
1500 ftz
0 0 1
::
ROOF
ry
Roof Gable Roof
Rad
Solar SA Emitt Emitt Deck Pitch
I
#
Type Materials Area I Area Color
-
Barr
Absor. Tested
Tested Insul. (deg)
1
Hip
Metal 7996 ftz I 0 ftz Unfinishe N
0.35 No
0.4 No 20 26.6
ATTIC
V #
Type
Ventilation I ant Ratio (1 in)
Area
RBS IRCC
1
Full attic
Unvented I 0
7150 ftz
N N
5/212019 3:44 PM EnergyGauge® USA 6.0.02 (Rev. 1) - Fla I es2017 FBC 6th Edition (2017) Compliant Software
Page 2 of 5
�lklnl 1T 0%111KARAAO I f%L1M4%VI IQT QCDnQT
ruRivi rc-ruu-cv i i
n.r v . .+v....... v...
.........
-
-
CEILING
#
Ceiling Type
Space I
R Value
Ins Type
Area
Framing Frac Truss Type
1
j Under Attic (Unvented)
Main 1
0
Blown
2543 ft2
0
Wood
2
Under Attic (Unvented)
Main 2
0
Blown
3107 ft2
0
Wood
3
Under Attic (Unvented)
Main 3
0
Blown
1500 ft2
0
Wood
WALLS
Adjacent
I Cavity
Width
Height
Sheathing Framing Solar Below
0
onit
To
Wall Type
Space
#
1
NW
Exterior
Concrete Block - Int Insul
Main 1
5
53
6 10
535.0 W
0
0 0.600000 0
_
2
SW
Exterior
Concrete Block - Int Insul
Main 1
5
36
4 10
363.3 ft2
0 0.600000 0
_
3
SW
Exterior
Concrete Block - Int Insul
Main 1
5
13
4 10
133.3 ft2
0 0.600000 0
_
4
W
Exterior
Concrete Block - Int Insul
Main 1
5
8
10
80.0 ft2
0 0.600000 0
_
5
S
Exterior
Concrete Block - Int Insul
Main 1
5
8
10
80.0 ft2
0 0.600000 0
_
6
SE
Garage
Frame - Wood
Main 1
13
34
6 10
345.0 ft2
0.23 0.600000 0
-
7
SE
Exterior
Concrete Block - Int Insul
Main 1
5
32
10
320.0 ft2
0 0.600000 0
_
8
NW
Exterior
Concrete Block - Int Insul
Main 2
5
65
14
5.
937.1 ft2
0 0.600000 0
_
9
SE
Exterior
Concrete Block - Int Insul
Main 2
5
20
8 14
5
297.9 ft2
0 0.600000 0
_
10
SE
Exterior
Concrete Block - Int Insul
Main 2
5
42
14
5
605.6 ft2
0 0.600000 0
_
11
NW
Exterior
Concrete Block - Int Insul
Main 3
5
34
10
340.0 ft2
0 0.600000 0
_
_ 12
NE
Exterior
Concrete Block - Int Insul
Main 3
5
53
10
530.0 ft2
0 0.600000 0
13
SE
Garage
Frame - Wood
Main 3
13
14
10
140.0 IF
0.23 0.600000 0
_
14
N
Exterior
Concrete Block - Int Insul
Main 3
5
27
10
270.0 ft2
0 0.600000 0
DOORS
#
Omt
Door Type
Space
I
Storms
U-Value Ft
In
In
Ft eightln Area
1
SE
Insulated
Main 1
None
.21
3
8 24 ft
2
SE
Insulated
Main 3
None
.21
3
8 24 ft2
WINDOWS
Orientation shown is, the entered, Proposed orientation.
Wall
I
Overhang
#
Omt ID
Frame Panes
NFRC
U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade Screening
1
NW 1
Vinyl Double (Clear)
Yes
63
0.21
Y
25.0 ft2
2 ft 0 in
3 It 0 in
Drapes/blinds Exterior 5
2
NW 1
Vinyl Double (Clear)
Yes
033
0.21
Y
15.0 ft2
2 ft 0 in
2 It 0 in
Drapes/blinds Exterior 5
3
NW 1
Vinyl Double (Clear)
Yes
0.3
0.24
Y
21.3 ft2
2 ft 0 in
2 ft0 in
Drapes/blinds Exterior 5
4
NW 1
Vinyl Double (Clear)
Yes
0129
0.23
Y
4.0 W
2 ft0 in
2 ft 0 in
Drapes/blinds Exterior 5
5
NW 1
Vinyl Double (Clear)
Yes
0133
0.21
Y
15.0 ft2
2 ft 0 in
2 ft 0 in
Drapes/blinds Exterior 5
6
SW 2
Vinyl Double (Clear)
Yes
0133
0.21
Y
36.0 ft2
2 ft 0 in
2 ft 0 in
Drapes/blinds Exterior 5
7
SW 2
Vinyl Double (Clear)
Yes
0.29
0.21
Y
12.0 ft2
2 ft 0 in
2 ft 0 in
Drapes/blinds Exterior 5
8
SW 3
Vinyl Double (Clear)
Yes
01�3
0.24
Y
40.0 f12
13 ft 0 in
2 ft 0 in
Drapes/blinds Exterior 5
9
SW 3
Vinyl Double (Clear)
Yes
0.28
0.24
Y
32.0 ft2
13 It 0 in
2 ft 0 in
Drapes/blinds Exterior 5
10
W 4
Vinyl Double (Clear)
Yes
0.83
0.21
Y
36.0 ft2
13 ft 0 in
2 ft 0 in
Drapes/blinds Exterior 5
11
S 5
Vinyl Double (Clear)
Yes
0.33
0.21
Y
36.0 1`12
13 It 0 in
2 ft 0 in
Drapes/blinds Exterior 5
12
SE 7
Vinyl Double (Clear)
Yes
06
0.21
Y
18.7 ft2
2 ft 0 in
2 It 0 in
Drapes/blinds Exterior 5
13
SE 7
Vinyl Double (Clear)
Yes
013
0.21
Y
8.0 ft2
2 It 0 in
2 ft 0 in
Drapes/blinds Exterior 5
5/2/2019 3:44 PM EnergyGauge® USA 6.0.02 (Rev. 1) - Fla i es2017 FBC 6th Edition (2017) Compliant Software
Page 3 of 5
ikint IT Qi wuAQ I �`1-t1G[ Kl ICT RFPC�RT
t•VRIVI RYV�J-GV !
Novo v •
vv....r..-o...
��
--
-- - -
WINDOWS
I
Orientation sho is the entered, Proposed orientation.
/
Wall
I
Overhang
Shade
Screening
V #
Ognt ID Frame
Panes
NFRC
-Factor SHGC
Imp
Area Depth
Separation
Int
14
NW 8 Vinyl
Double (Clear)
Yes
0.27 0.25
Y
240.0 ft2 17 it 0 in
2 ft 0 in
Drapesiblinds
Exterior 5
15
NW 8 Vinyl
Double (Clear)
Yes
0.3 0.21
Y
30.0 ft2 17 ft 0 in
4 ft 0 in
Drapesiblinds
Exterior 5
16
SE 9 Vinyl
Double (Clear)
Yes
0.33 0.21
Y
63.0 ft2 2 it 0 in
4 ft 0 in
Drapes/blinds
Exterior 5
17
SE 9 Vinyl
Double (Clear)
Yes
0.29 0.23
Y
16.0 ft2 2 ft 0 in
2 It 0 in
Drapesiblinds
Exterior 5
18
SE 10 Vinyl
Double (Clear)
Yes
0.3 0.21
Y
60.0 ft2 12 ft 0 in
4 It 0 in
Drapesiblinds
Exterior 5
19
SE 10 Vinyl
Double (Clear)
Yes
0.33 0.21
Y
63.0 ft2 12 ft 0 in
4 it 0 in
Drapesiblinds
Exterior 5
20
SE 10 Vinyl
Double (Clear)
Yes
0.3 0.21
Y
17.3 ft2 12 ft 0 in
2 ft 0 in
Drapes/blinds
Exterior 5
21
SE 9 Vinyl
Double (Clear)
Yes
0.3 0.21
Y
4.0 ft2 2 ft 0 in
2 ft 0 in
Drapesiblinds
Exterior 5
22
NW 11 Vinyl
Double (Clear)
Yes
0.33 0.21
N
20.0 fie 2 ft 0 in
2 ft 0 in
Drapes/blinds
Exterior 5
23
NW 11 Vinyl
Double (Clear)
Yes
0.33 0.21
Y
25.0 ft2 2 It 0 in
2 It 0 in
Drapesiblinds
Exterior 5
24
SE 9 Vinyl
Double (Clear)
Yes
1 .28 0.24
Y
10.0 ft2 2 ft 0 in
2 ft 0 in
Drapesiblinds
Exterior 5
25
NE 12 Vinyl
Double (Clear)
Yes
1 .33 0.21
Y
36.0 W 2 ft 0 in
2 It 0 in
Drapes/blinds
Exterior 5
26
NE 12 Vinyl
Double (Clear)
Yes
0.28 0.24
Y
10.0 ft2 2 It 0 in
2 it 0 in
Drapesiblinds
Exterior 5
27
N 14 Vinyl
Double (Clear)
Yes
6.33 0.21
Y
18.7 ft2 2 ft 0 in
2 ft 0 in
Drapesiblinds
Exterior 5
28
N 14 Vinyl
Double (Clear)
Yes
0.3 0.21
Y
19.8 ftz 2 ft 0 in
4 ft 0 in
Drapesiblinds
Exterior 5
29
N 14 Vinyl
Double (Clear)
Yes
0.3 0.21
Y
4.0 ft' 2 ft 0 in
2 ft 0 in
Drapes/blinds
Exterior 5
(GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
2061.95 ft2
2061.95 ft2
I 211 ft
loft
1
INFILTRATION
# Scope
Method
SLA
CFM II 0 ELA
EgIA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .00038
7123.i 391.07
735.46 .1546
5
HEATING SYSTEM
i
F1-
System Type
Subtype
Efficiency Capacity
Block
Ducts
Electric Strip Heat/
None
COP:1
36 kBtu/hr
1
sys#1
2
Electric Strip Heat/
None
COPA
34 kBtu/hr
2
sys#2
3
Electric Strip Heat/
None
COP:1
26 kBtuthr
3
sys#3
COOLING SYSTEM
i
#
System Type
Subtype
I
Efficiency
Capacity
Air Flow
SHR Block
Ducts
1
Central Unit/
None
I
SEER: 17
36.4 kBtu/hr 1092
cfm
0.76 1
sys#1
2
Central Unit/
None
SEER:16
48.5 kBtu/hr 1455
cfm
0.75 2
sys#2
3
Central Unit/
None
I
SEER: 17 25.6 kBtu/hr 768 cfm
0.75 3
sys#3
5/2/2019 3:44 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
AAA 7 IKIC21 1T QI IRARAA DI f`uGc6[f IST 09=PnRT
HOT WATER SYSTEM
i
• # System Type
SubType
Location
�F Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.92 40 gal
80 gal
120 deg
None
j
SOLAR HOT WATER SYSTEM
i
FSEC
I
Collector Storage
Cert # Company Name
System Model # Collector Model # Area Volume
FEF
None None
I
ft2
DUCTS
- Supply —
— ReturnAir
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT QN
RLF
Heat Cool
1 Attic
6 420 ft2
Attic
200Ift2 Default Leakage
Garage
(Default)
(Default)
1 1
2 Attic
6 500 ft2
Attic
178.7 f Default Leakage
Garage
(Default)
(Default)
2 2
3 Attic
6 476.666
Attic
119.1,66 Default Leakage
Garage
(Default) (Default)
3 3
TEMPERATURES
i
Programable Thermostat: Y
Ceiling Fans:
Cooling Jan Feb
Heating Jan Feb
Mar
Mar
Apr
pr
May X Jun Jul
May Jun Jul
Aul
rl Au
X Se
Sep
Oct
Oct
[[ �Nov
[X] Nov
Dec
Dec
Venting Jan Feb
X Mar
A r
[ ]]] Ma l Jun [ Jul
L L
Aug
[jjj Se
Oct
[[XX]] Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9 10
11
12
Cooling (WD) AM
PM
78
80
78
80
78
78
78 78 78
78 78 78
78
78
78
78
80 80
78 78
80
78
80
78
Cooling (WEH) AM
PM
78
78
78
78
78
78
78 78 78
78 78 78
78
78
78
78
78 78
78 78
78
78
78
78
Heating(WD) AM
PM
66
68
66
68
66
68
66 66 68
68 68 68
68
68
68
68
68 68
68 68
68
66
68
66
Heating (WEH) PM
68
68
68
64 68 68
68
68
68 68
66
66
MASS
Mass Type
Area
I Thickness
Furniture Fraction
Space
Defautt(8 Ibs/sq.ft.
0 ft2
Oft
0.3
Main 1
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Main 2
Default 8 lbs/sq.ft.
0 ft2
O ft
0.3
Main 3
5/2/2019 3:44 PM EnergyGauge® USA 6.0.02 (Rev. 1) - Flal2es2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. _ Ne From Plans) 12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family 2. Sin I le- family b) Return ducts R
6.06.0
c) AHU location
I
Garage
3. No. of units (if multiple -family) 3. 1
4. Number of bedrooms 4. I 5 13. Cooling system: Capacity
110.5
a) Split system SEER_
5. Is this a worst case? (yes/no) 5. b) Single package SEER
c) Ground/water source SEERICOP
6. Conditioned floor area (sq. ft.) 6. 7150 d) Room unit/PTAC EER
e) Other
varies
7. Windows, type and area
a) U-factor:(weighted average)
b) Solar Heat Gain Coefficient (SHGC)
c) Area
8. Skylights
a) U-factor:(weighted average)
b) Solar Heat Gain Coefficient (SHGC)
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior.
1. Wood frame (insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
8b
10A1
10A2
10B1
10132
11
1 'I
11
11
*Label required by Section R303.1.3 of the Florida
14. Heating system: Capacity 96.0
a) Split system heat pump HSPF-
b) Single package heat pump HSPF
c) Electric resistance COP 1.0
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
f) Other
15. Water heating system
a) Electric resistance EF 0.92
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF
f) Heat recovery unit HeatRec%,_
g) Other
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
b) Cross ventilation No
c) Whole house fan No
d) Multizone cooling credit
e) Multizone heating credit
f) Programmable thermostat Yes
Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed basedeon installed code compliant features.
Builder
Address of New Home:
Date:
City/FL Zip: Port St Lucie FL 34986
51=019 3:45:19 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (201 7) Compliant Software Page 1 of 1
Envelope LeakagIe Test Report (Blowier Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
A 2017 Florida Building Code, Energy, Conservation, 6th Edition
Jurisdiction: 612000
Permit #:
nlclb lr�folrnlatian
} .
r ,• �_
Builder: Communiy:
Lot: NA
Address: 9632 Enclave Circle
City: Port St Lucie
State: FL Zip: 34986
�liirLe�k�g1e'T�,st ��sull��� Passrrig
st meef ert�reriher Feii�fanrat �'re�sGnp#�si�, `vr E'R1 Mefhad�'�' ' F
� ;resudfs'�y
�
r>} 3
"PRESC>E:iP ME1 sn dweUu�g unithaif k►e'`tesfed and,venfied a$vmg att rate of nat 8ditig=7 air ;
HCp Thebu�dirrg �rrxteaka
f� changes Ifaur�at e`pressure d�0.� mGh w �. (5a l�'asaa�s} rn 4"iin►ate caries 4 and 2 ,, J � r ,� } � y �e
�
pier r ,
l� , [l15
1�-N '!; �, 4
"�:..
's '' T 4 .� _ Y }i'.}•'� �, t : M r'^ 3 , l:x
PERFGRIIdAWO oifRt Mfi?liOp-Thy 5uifding of dwelh ►g undstt'aall be test �f gild v�rifisd as having aI� a�irTeatsagerrat o#xr►at exceeding
._ .
the selected AC�I(5Q}value, as shown on Farm R4U�2d7;{�Per�urinancej os R4Q�-20'17 (Eft), seahan`[abeterk as iritittiabion.s�6-si�ctioii�►CH50;
� l
r' � l?9!05 201 i`-Erietgy CeIC �F'erCortnance) ar`R414B-21ff � (Efdly ' 5.000
r f s fiy �4Gfl{�0) speGtr�d pn�l�drm,
x 60 i 85482 Method for calculating building volume:
CFM(50) Building Volume ACH(50) O Retrieved from architectural plans
F� PASS • Code software calculated
When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated
must be^verified by building department.
R402.4.1.2 Testing. Testing shall be conducted in accordance 4 ANSIJRESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals).
Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues. or individuals licensed asset forth in Section
489.105(3)(f) (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration
control measures.
flue
2. Dampers including exhaust, intake, makeup air, back draft and dampers shall be closed, but not sealed beyond intended infiltration control
measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, l all be turned off.
be fully
6. Supply and return registers, if installed at the time of the test, shall open.
]ftlt�r,�'
Et-d
a ;
Company Name:
Phone:
I hereby verify that the above Air Leakage results are in
accordance with the 2017 6th Edition Florida Building Code
Energy Conservation requirements according to the co
pliance method selected above.
Signature of Tester:
Date of Test:
Printed Name of Tester:
License/Certification #:
Issuing Authority:
5/2/2019 3:45:40 PM EnergyGauge® USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1