Loading...
HomeMy WebLinkAboutGENERATOR CONCRETE PADY N c� 0 0 Y w O m 0 0 0 AMERICAST GENERATOR CONCRETE PAD SCANNED GENERATOR_I BY �\ I St Lucie County THICKNESS �5 GLEN PAD DIMENSIONS: CONCRETE GENERATOR ,i �•. CONCRETE PAD t; ROAD MESH - MASTERFIBER = _ 2� .MIN 4" MIN MAC100 - -, 1 s n GROUND %� -: / %• ' = -Z„ MIN 45" 1 41 TYP. ISOMETRIC VIEW GENERATOR TABLE: (ON -GRADE APPLICATIONS ONLY) AMERICAST rksanuam •EiADID �" FED TAX 020.3252362 L10E%MdSN=50153 SM PWMCM Ave. Fen tierce. FL 3002 T.L T11-071-19Si F 772-164-0SOD EMBIL u1�mMarWommar ehnfno1Kt00/(�Iwbo.a HVHZ OR NON-HVHZ ' RISK EXPOSURE RISK EXPOSURE ==RISK, if .:EXPOSURE= I COUNTY 1 C D 11 C' D -III; IV C, _ D. P. BEACH 150 MPH 32.43 Psf 39.33 Psf 170 MPH 41.65 Psf 50.55 Psf 180 MPH 46J0 Psf 56'67psf BROWARD 156 MPH 35.08 Psf 42.57 Psf 170 MPH 41.65 Psf 50.55 Psf 180 MPH 46.70 Psf 56.67 Psf MIAMI-DADE 165 MPH 39.24 Psf 47.62 Psf 175 MPH 44.14 Psf 53.57 Psf 186 MPH 49.86 Psf 60.52 Psf BRAND MODELS -- CAPACITY`- i LENGTH:= WIDTH,, 4, ;j - HEIGHT i WEIGHT ALLOWABLE PRESSURE COMMENTS QT02224ANAX ! L22KW "- 62.2 in`: , 29:Ojn' ; 33.5 in 843 lb 60.S2 Psf RG022 / RG02224ANAX 22KW- . � i 62.2 in '3D.6 in` 38.6 in 905 lb 60.52 Psf 'I RG025 / RG02515A ALUM i j 25K1N: ^='-. 62.2 in 30.67in 38.6 in 777 lb 60.52 Psf '? RG025 / RG02515S STL ! _ 25KW�_ -62.2 in , % 30�6 ink:. 38.6 in 865 lb 60.52 Psf 1 RG027 / RG02724ANAX 27KW--_ 62.2.inP' ;k6 in `38.6 in 940 lb 60.52 Psf i RG030 / RG03015ANAX ALUM 30KW = 62i2 iw- '30.6 in 38.6 in 807 lb 60.52 Psf U RG030 / RG03015ANSX STL 30KW 62 2-m 30 6 sn , 38.6 in-,895 lb 60.52 Psf w RG032 / RG3224ANAX 32KW� a 4 76 $in;i` _35 0 sn 1 46:1+in` `a1225 lb 60.52 Psf I UP TO EXPOSURE v RG036 / RG03624ANAX ALUM k-36KW,, ;-_ , 76:8 in- 35:0;in _ =40A in 1202 lb 60.52 Psf t D 186 MPH O RG036 / RG03624ANSX STL 36KW3 ij� r76 8 in - 35 0'in e'46.1 in 1255 lb 60.52 Psf RG038 / RG3824ANAX 38KW 76.8 in 35.0 in 46.1 in 1235 lb 60.52 Psf RG045 / RG452ANA C (X) ALUM 45KW 76.8 in 35.0 in 46.1 in 1260 lb 60.52 Psf RG04S / RG4S2ANS(C)(X) STL 45KW 76.8 in 35.0 in 46.1 in 1313 lb 60.52 Psf RG048/ QT048 / RG4854ANA(C)(X) 48KW 76.8 in 35.0 in 46.1 in 1555 lb 60.52 Psf RG060 / ALUM 60KW 76.8 in 35.0 in 46.1 in 1422 lb 60.52 Psf RG060 /STEEL 60KW 76_8� 5.0 in--463-in 539-lb -60-.52 Psf , r -24RCr/30RC 30RES 24KW 33.0 in 74.0 in 1260 lb 60.52 Psf i UP TO EXPOSURE D 186 MPF 30KW 34.0 in 72.8 in 30461b 60.52 Psf o s� 30REOZIB 30KW 34.0 in 78.7 in 15601b 60.52 Psf IE B&S 076000 30KW 34.0 in 78.7 in fl41.55 1560 Ib 60.52 Psf UP TO E GE 076034 30KW 39.5 in 84.5 in 18001b 60.52 Psf D 186 Cummins RS22C22 N6 22KW 72.0 in 34.0 in 11 99 Ib 41.65 Psf EXP C 17 GENERATOR MOUNTING CONFIGURATION: GENERATOR ATTACHMENT BASE OR SIMPSON A24 ANGLE BRACE GENERATOR W/ (4) #10 SS 316 SELF -DRILLING SCREWS TO GENERATOR (SEE GENERATOR SPECS) WIND DESIGN REOUIREMENTS1 (BASED ON ASCE 7-10 & FLORIDA BUILDING CODE SIXTH EDITION (2017)) AT -GRADE SIGN METHOD ' ULTIMATE DESIGN WIND SPEED Vult = 186 mph NOMINAL DESIGN WIND SPEED ,Vasd = 144 mph RISK CATEGORY = III " INTERNAL PRESSURE COEF = N/A EXPOSURE CATEGORY = D WIND DIRECTIONALITY FACTOR Kd= 0.85 ENCLOSURE CATEGORY = N/A HEIGHT H = AT GROUND GUST EFFECT FACTOR = 0.85 PRESSURE AT HEIGHT H qh = 77.56 Ib/ft2 FORCE COEFFICIENT Cf = 1.53 ' WIND PRESSURE: P = qh G Cf = 60.52 Ib/ft2 (ASD) ANCHOR TO PAD SCHEDULE: SUBSTRATE DESCRIPTION (4)-3/8"0 TITEN HD CONCRETE: OR EQUIVALENT, 2" (6000 PSI FULL EMBED TO MIN.) CONCRETE, 3" MIN. EDGE DISTANCE, 6" MIN. SPACING TO ANY ADJACENT ANCHOR. NOTES: 1. ANCHOR QUANTITY PER LONG SIDE 2. EMBEDMENT AND EDGE DISTANCE 3. XPOSURE �I �_; ! INSTALLAT MPH y a• INSTALL A 0 MPH -_ GENERATOR �ATtTACHMENT BASE, . = VARIES WITH MODEL'S - SEE`GENERATOR.SPECSi `- SIMPSON TITEN HD, / SEE ANCHOR SCHEDULE 2"x3"x%" GALV. STEEL WASHER RUBBER VIBRATION PAD 3/g' THICK _ �eQ Q _ GALVANIZED WASHER 7 ( &RUBBER 'VIBRATION -PAD. /: _ / 7 _ = GENERATOR ( t�. H (SEE CONCRETE PAD SCHEDULE FOR ) S' w W DIMENSIONS &WEIGHT REQUIRED) . CONCRETE -PAD s l LIGHTWEIGHT:-- CONCRETE MIX°�-.I n IL 4„ I TES') l 1)' Y DISTANCE-DEPEND'ON GENERATOR BASE LENGTH, NO LESS THAN 2 OR.,ANCHOR REQUIREMENT. }47" WIDTH }45" LENGTH �45" LENGTH ;' w "Jz' ` X'DISTANCE.3-,FROM UNIT EDGE TO CLIP. 3. Z DISTANCE DEPEND ON GENERATOR BASE WIDTH, NO LESS SIDE VIEW FRONT VIEW THAN ANCHOR REQUIREMENTS 4,EDGE DISTANCE fHOR SCHEDULE. 9 SPACING TO N 011S. CTURER'S ISTRUCTIONS TO S , CONCRETE PAD ¢ N 6,000 PSI A LIGHTWEIGHT CONCRETE MIX / I1 MASTERFIBER MAC 100 & ROAD MESH FOA RECEIVED APR 3 4 L098 Lucie County, Permitting GENERAL NOTES 1. THIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE SIXTH EDITION (2017). 2. REQUIRED WIND LOAD DESIGN PRESSURES CALCULATED FOR USE WITH THIS SYSTEM SHALL BE DETERMINED UNDER SEPARATE CERTIFICATION ON A JOB -SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE. SITE -SPECIFIC LOAD REQUIREMENTS AS DETERMINED -IN -ACCORDANCE WITH THE APPLICABLE CODE SHALL$E-LESS.THAN:OR EQUAL TO THE DESIGN=-PRESSURE'ASD_' CAPACITY,UALUES LISTED HEREIN F'OR'ANY.ASSEMBL-Y AS -SHOWN. / _ { 3. DIMENSIONS AND WEIGHT OF UNITS'SHALL`CONFORM TO 4. UNITS MUST BE CENTERED ON"PAD-WITH OPPOSITE SIDES HAVING EQUAL CLEARANCE. A MINIMUM DISTANCE FROM UNIT TO PAD EDGE IS! SPECIFIED. - ­•-__ Y 5. THE AREA UNDER CONCERETE-SLAB ON";GROUND-SHALL HAVE ALL VEGETATION, STUMPS, ROOTS,'AND FOREIGN MATERIALS REMOVED PRIOR TO INSTALLATION ON COMPACTED SOIL AS VERIFIED BY. OTHERS. , 6. RESISTANCES,, LI SDING OFWE;PAD ON THE GROUND IS NOT PART OF THIS DOCUNT AS.SOIL CHARACCERISTICS AND PAD ME PLACEMENT VARIES.: / 7. ELECTRICAL GROUND; WHEN REQUIRED, TO`BE DESIGNED & INSTALLED BY OTHERS. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.) SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. -8.-ENGINEERSEA WFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION, CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN. 9. WATER -TIGHTNESS OF EXISTING FINISHES SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. CONTRACTOR SHALL ENSURE THAT ANY REMOVED OR ALTERED WATERPROOFING MEMBRANE IS RESTORED AFTER FABRICATION AND INSTALLATION OF STRUCTURE PROPOSED HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY WATERPROOFING OR LEAKAGE ISSUES WHICH MAY OCCUR AS WATER -TIGHTNESS SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. 10. THE ROLE OF THIS ENGINEER FOR THIS PROJECT IS THAT OF SPECIALTY ENGINEER AND NOT THE ENGINEER OF RECORD. CONSEQUENTLY, THE ARCHITECT/ENGINEER OF RECORD SHALL BE RESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL BE COORDINATED BY THE PERMITTING CONTRACTOR: 11. THIS DOCUMENT IS-GENERICAND"DOES NOT PERTAIN,TO ANY SPECIFIC PROJECT SITE -INFORMATION CONTAINED HEREIN IS TBASED ON CONTRACTOR -SUPPLIED DATA AND MEASUREMENTS. ENGINEERING EXPRESS SHALL NOT'BEHELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA d OR MEASUREMENTS "D*IMENSIONS:ARE SHOWN TO.ILLUSTRATE DESIGN FORCESIAND_OTHER-DESIGN CRITERIA THEY MAY VARY SLIGHTLY, BUTMUST REMAIN WITHINjTHE LIMITATIONS SPECIFIED HEREIN. WORK-SHAL'L`BE FIELD/VERIFIED BY OTHERS PRIOR TO CONSTRUCTIONJENGINEERING EXPRESS SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO REEVALUATE'OUR,WORK'UPON'DISCOVERYOFANY j INACCURATE-'INFORMATIOPN PRIORTO MODIFICATION OF - - EXISTING FIELD CONDITIONS AND,"FABRICATION AND zz. INSTALLATION OF.MATERIALST AL•TERAIIONS_OR ADDITIONS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION. 12. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. VK L. BENN1jRDO, P.E. 0046549 J 01 'jA4! i2018 P.E. APPEARS BELOW DO, P.E. SIGNATURE ON SHEET 1, THIS SHEET IS PART OF A DIGITALLY SIGNED FILE, SHALL REMAIN IN DIGITAL FORMAT, & PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED. IF THERE IS NO DIGITAL SIGNATURE ON SHEET 1 OR THIS SHEET DOES NOT CONTAIN AN ENGINEER'S ORIGINAL SIGNATURE & SEAL, U 0 N Z Od It 00 ffO LLI M ,., U F �MLn0 ui r J cWU00 W� LL(f) ` XV)# WW O 2�r;wax ZLU LLIU CL L7�I-'aLL-.Wa gQ W -.w00 O.rz m o Z Z F Of WW 0-j 'wWU O� W ,,O,Z-, 1 1 v -1 V) W a=w O W w ID t] 0 o a¢ z OUj La v /� -z o ¢ u- In Y x UFOw� Cri F-?~ _ W 1 dS w w a � U) O Lu a n ozc1 C M O `t (D L o LL Y -j G� w U m w ¢ ¢ � � O K O LL. Q a � O NOZ¢Z _LL CO m zoF 000ci ?s O 00 a�z�o a0 �aw a -moz w o oz=o Y w O �z c,n.. .iWW Q¢ GO��W-H n w FE- 1: r 0: Z N COPYRIGHT 172 EN3961IXsS® SCALE: NTS UNLESS NOTED OFq u I