Florida Product Approval #11651.13 R2
Florida Building Code 2014
RECEIVED Per Rule 61 G20-3
Method: 1 -D
APR 3 0 20118
ST. Lucie county, Permitting Category: Roofing
Subcategory: Metal Roofing
Compliance Method: 61G20-3.005(1)(d)
NON HVHZ
c�
r S'**4
4<
SCANNED
BY
St Lucie County
Product Manufacturer:
Gulf Coast SuI�ply & Manufacturing, LLC.
14429 SW 2nd Place, Suite G30 +j++IIIjj
Newberry, FL 32669 ,%,OPN�EL S., jr4 y'
E � gineer Evaluator:
Dan Kuhn, P.E. #75519
Florida !Eva Iuation ANE ID: 10743
Validator:
Locke Bowden, P.E. #49704
9450 Alysbury Place
Montgomery, AL 36117
I
Contents:
Evaluation Report Pages 1 - 5
* : No, 75519 r
STATE OF •'Q:
-
1++11+
0 3072015
Table "A"
4/J�06Z// A i e vd d N bQ4114 Hsi L,3° 7d%xs
Maxi�rnum Tota{ Uplift Design PresStre; 4 r994'25psf�; ,1�1Q psf:y,
Fastener Pattern 12"-12"
9.5" 2" 9 5"
Fastener Pattern'Spacmg �,A� ,1`6'�O=C w a' � o�� 1` 0 C r,
Design Pressure includes a Safety Factor = 2.0.
i
r
GulfICTOf
SUPPLY & MANUFACTURING
Compliance Statement:
The product as described in this report has demonstrated compliance with the
Florida Building Code 2014, Sections 1504.3.2.
Product Description:
5V Crimp Roof Panel 26 Ga. Steel, 24" Coverage, through fastened
roof panel with fasteners in the panel flat over minimum 15/32" plywood decking.
Non Structural application.
Panel Material/Standards:
Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to
Florida Building Code 2014 Section 1507.4.3.
Paint Finish Optional
Yield Strength: 80.0 ksi
Corrosion Resistance: Panel Material shall comply with Florida Building Code
2014, Section 1507.4.3.
Panel Dimension(s):
Thickness: OI018" Minimum
Width: 24" Coverage
Rib Height: 3/s" Major Rib
Panel Fastener:
#9-15x1.5" with sealing washing in the flat of the panel or approved equal,
1/a" minimum penetration through plywood.
Corrosion Resistance: Per Florida Building Code 2014, Section 1506.6, 1507.4.4
15/32" thick over supports at maximum 24" O.C.
ick, APA Rated
Substrate Description:
Minimum plywood
'
Design of plywood and plywood supports are outside the scope of this evaluation.
Must he designed in accordance w/ Florida Building Code 2014.
Design Uplift Pressures:
FL# 11651.13 R2 9 JUNE 15, 2015
00 Gulf7
FLORI® SUPPLY & MANUFACTURING
Code Compliance: The product described herein has demonstrated compliance with the
Florida Building Codei2014, Sections 1504.3.2.
Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2014, as relates to Rule 61G20-3.
Performance Standards: The product described herein has demonstrated compliance with:
• UL 580-06 - Test for Uplift Resistance of Roof Assemblies
• UL I1897-04 - Uplift Test for Roof Covering Systems.
Reference Data: 1. UL 580-94 % 1897-98 Uplift Test
Force Engineering & Testing, Inc. (FBC Organization # TST 5328)
Report No 1 117-0053T-05 & 117-0331T-08
2. Certificate, Independence
By Dan Kuhn, P.E. (FL# 75519) @ Kuhn Engineering, LLC
(FBC Organization # ANE ID: 10743)
Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard.
2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test
standard
Quality Assurance Entity: The manufactures has established compliance of roof panel products in
accordance wit�ncler
the Florida Building Code and Rule 61 G20-3.005(3) for
manufacturing a quality assurance program audited by an approved quality
assurance entity
Minimum Slope Range: Minimum SlopeIshall comply with Florida Building Code 2014, including
Section 1507.412 and in accordance with Manufacturers recommendations. For
slopes less than 3:12, lap sealant must be used in the panel side laps.
Installation: Install per Manufacturer's recommended details.
Underlayment: Shall comply with Florida Building Code 2014 section 1507.4.5.1 and 1507.4.5.2.
Roof Panel Fire Classification: Fire classification is not part of.this acceptance. �\
Shear Diaphragm:
Shear Diaphragm values are outside the scope of this report.
1
Design Procedure:
FL# 11651.13 R2 9 JUNE 15, 2015
For roofs within the
at a minimum meet
the parameters lister
for each project in a
using allowable stre.
not be exceeded. Tr
Hurricane Zone. Ref
product in High Vel(
)arameters listed on the load table, fastening pattern must
I
ose listed for the applicable wind zone. For all roofs outside
Ion the load table, design wind loads shall be determined
cordance with FBC 2014 Section 1609 or ASCE 7-10
design. The maximum fastener spacing listed herein shall
s evaluation report is not applicable in High Velocity
r to current NOA or HVHZ evaluation report for use of this
Jtv Hurricane Zone.
ENGINEER LOAD TABLE: 26 Ga. 5VCrimp Roof Panel over 1�5/32" Plywood a / uaH ra
Raaf IVlean.Hej ht 5 2Q Q;d, Rocs ,5(ope 2"I12" - 12"/12." Gab1e°or NIp. Roof, it1(ind yeecis 1, 0 ,
Buildings having a 19
184m h "EX osiire RIsK Catei�t II Ericlased a ltllrlbasetl on Florltla Building:;Cotle 2C)1Aru,r, : v s
•Ju.„ IaY, u. G,/2�' ..Oi.�9am//iA: e. R,d,
p"�,a l.P
120 130 j 140 150 160 170 180
WIIND FASTENER SUBSTRATE
ENTER
(MIN. 1/4" (MIN. 15/32") ON CENTER ON CENTERER ON CENTER ON C
I ON CENTER ON CENTER ON CENT
SPEED
Penetration) SPACING SPACING SPACING SPACING SPACING SPACING SPACING
r air ti2�tiu ai
w " w, , , r• yii / JHNq!a %0/�iiauaa// ii� , , i , "
20NEµ 7 #9-15x1.5"N Plywood 16" TYPE6" TYPE 1 16 TYPE 1" i6, TYPE 1 1;6"TYPE"1 1f TYPE 1 '�16 /TYPE 1
ZONE 2 #9-15x1.5" Plywood 16" TYPE 1 16" TYPE 1I 16" TYPE 1 16" TYPE 1 16" TYPE 1 16" TYPE 1 16" TYPE 1
as xa air am i mudan!iiN%////ar Niiu/a,✓,.✓a„
a 5� r an4/e�r/ ,�aG rq•M, r p x"
;gZCONE 3 #9-15x1.5 Plywood w16" TYPE 1 16TYP6 t 16 TYPE 1".." 16„TYPE 1 16 TYPE'1� /18�„TYPE 2 � �16, PE,,2
1.) PANEL DESCRIPTION: 5V CRIMP, MIN. 26 GA., GRADE 80, 24"COVERAGE.
2.) PANEL FASTENER: #9-15X1.5" HWH WITH SEALING WASHER W/ MIN.'/4" PENETRATION.
3.) MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE: -94.25 PSF@ 16" O.C. FASTENER SPACING TYPE 1 FASTENER PATTERN, -131.0
PSF @16" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING.
4.) PLYWOOD DECKING: MIN.75/3z" THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2014.
5.) ROOF SLOPE: ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS.
6.) LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10 (KD = 0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING
CODE 2014
HIP ROOF a Note: Dimension (a) is defined as 10% of the minimum width of the building or
T\\
E 2 ZONE 3 40% of the mean height of the roof, whichever is smaller, however, (a) cannot be
a
less than either 4% of the minimum width of the building or 3 feet.
RIDGE ; TYPE 1 FASTENER PATTERN
(1) #9-15 x
ZONE 1-1/2" HWH w/Sealing Washer
I , \
12�� 1211
�� ��
/-----------------\�
-_„- At Panel Lap
ZONE 2 GABLE ROOF
I
— — -----------------I �a
I I
RIDGE
I I
----- -- ------------I
a
+---------------------4
a
I
ZONE 1
I I
I I
'-�—ZONE3 \—EAVE
FL# 11651.13 R2 • JUNE 15, 2015
TYPE 2 FASTENER PATTERN
(1) #9-15 x 1-1/2" HWH w/Sealing Washer
I
IN