Loading...
HomeMy WebLinkAboutWALL ASSEMBLY DETAILPREFORMED CONTROL JOINT FLANGE OF CONTROL JOINTS TO BE WIRE TIED TO LATH 0 9" O.C. MAX (VERT.). NOTE: DO NOT FASTEN CONTROL JOINT TO WALL EVEN IF STUD EXISTS BEYOND EXCEPT STAPLES W/ %8' LEG MAY BE USED TO TEMP. SECURE CONTROL JOINT DURING INSTALLATION TEMPORARY STAPLES TO BE REMOVED AFTER INSTALLATION FASTENERS TO BE SPACED tv i' O.C. MAX VERTICALLY LATH SHALL NOT BE CONTINUOUS THROUGH CONTROL JOINTS BUT SHALL BE STOPPED AND TIED AT EACH SIDE. PER ASTM CI063 1.10.1.4 NOTE: 1. FASTENERS FOR LATH TO BE NAILS OR STAPLES IN COMPLIANCE W/ ASTM CI063 2. WIRE TIES TO BE (NO. 18) 0.0415' WIRE 3. BLOCKING SHOWN MAY BE IN ADDITION TO I WALL STUDS REQUIRED PER PLAN CUT TWO PIECES OF FORM FLASH I — APPROX. (o" LONGER THAN THE WIDTH OF PIPE OPENING LOCTITE SPRAY ADHESIVE DIRECTLY TO 055 AROUND PENETRATION 'OR LE55 PIPE PENETRATION �. STARTING WITH THE BOTTOM HALF OF THE PIPE, REMOVE THE RELEASE LINER AND FOLD THE FORM FLASH 1 IN HALF (LENGTH WISE WITH ADHESIVE TO THE EXTERIOR) ALIGN THE PROTECTO FORM FLASH I WITH THE CENTER OF THE PIPE. ADHERE FORM FLASH I TO THE BOTTOM HALF OF THE PIPE AND WRAP AROUND THE PIPE. PER FBC R103.1.1 EXTERIOR LATHING AND PLASTERING EXTERIOR USE OF PORTLAND CEMENT PLASTER SHALL COMPLY WITH THE APPLICATION REQUIREMENTS OF ASTM C 926-12A. INSTALLATION OF EXTERIOR LATHING AND FRAMING SHALL COMPLY WITH A5TM C 1063-12A RTF.P 1 INSTALL FASTENERS (CLIPS, STRAPS, STAPLES) AS REQUIRED TO SECURE PIPE/ WIRE TO FRAMING /'PIPE PENETRATION DETAIL w TO 8' 8' THICK, 3 COAT CEMENT PLASTER WRB LAYER 02, FORTIP15ER BUILDING PAPER (OR APPROVED EQUAL) APPROVED METAL LATH FASTENED si" (VERT.) O.C. MAX AT SUPPORTS WRB LAYER *I, 5TUCCOWRAP (OR APPROVED EQUAL) WOOD SHEATHING PROTECTED FLASH TAPE BEHIND CONTROL JOINT PROVIDE 2X4 BLOCKING PLACED FLAT MAX. 6" TO 8" FROM CONTROL JOINT WHEN CONTROL JOINT FALLS ON STRUCTURAL 'STUD .,TYPE " ' CONTROL JOINT xate: Nxa NOTE: APPLY SEALANT AT 'M' CONTROL JOINT END TO END CONDITIONS //7USE FINGERS TO MOLD THE REMAINING HALF OF THE FORM FLASH I TO THE SHEATHING, MAKING SURE THE FORM FLASH 1 IS TIGHT TO THE PIPE AND TO THE \ SHEATHING WITH MINIMAL AIR POCKETS OR BUBBLES. STEP 2 SECTION TAKE SECOND PIECE OF FORM FLASH I AND APPLY IT TO THE TOP HALF OF THE PIPE IN THE SAME MANNER, MAKING SURE THE OVERLAP AREAS ,ARE PRESSED DOWN TIGHT TO THE PIPE AND SHEATHING. TAPE WRB LAYER 1, STUCCOWRAP (OR APPROVED EQUAL) DIRECTLY TO SHEATHING WRB LAYER *2, FORTIFIBER BUILDING PAPER (OR APPROVED EQUAL) METAL LATH PROTECT1 FORM FLASH I CONFORMABLE AIR/VAPOR BARRIER TAPE DIRECTLY TO SHEATHING LOCTITE SPRAY ADHESIVE DIRECTLY TO 055 AROUND PENETRATION ELASTOMERIC COATING (OR APPROVED EQUAL) OVER STUCCO/ C.V. FINISH (SEE TYP WALL SECTION) NOTE: SIDE LAPS OF METAL PLASTER BASES SHALL BE SECURED TO FRAMING MEMBERS. THEY SHALL BE TIED BETWEEN SUPPORTS WITH 0.0415-IN. (1.21-MM) WIRE AT INTERVALS NOT MORE THAN 91 1 (229-MM). AS PER ASTM C1063 1.8.1. NOTE: FOR REPAIR OF TEARS IN WRB LAYERS, TEARS MAY BE PATCHED PEEL E STICK WOOD 5% z y SHEATH WRB I TAPED Ti SHEATHING w/ WI 02 OVER TOP. WF #2 TO BE LAPPE_ VERTICALLY 6" MIN. STUCCO OVER METAL LATH. METAL LATH TO HAVE 1' VERTICAL LAP MIN. HORIZONTAL LATH & PAPER DETAIL SIDING wrr%p L-A 1 GR 'L, FORTIF15ER BUILDING PAPER (OR APPROVED EQUAL) PAPER LAP 2 s-ALE: N.ra WOOD SHEATHING WATER RESISTIVE BARRIER LAP SIDING (PER BUILDER) MINIMUM LAP (PER MANUF. SPECS) WEEP SCREED STARTER STRIP (PER MANUF. SPECS) MINIMUM CLEARANCE (PER MANUF. SPECS) 5'Xl' CONTINUOUS GALV. METAL STEP FLASHING (NAIL TO ROOF DECK, NOT WALL SHEATHING) CAP SHINGLE - DO NOT NAIL ADHERED SHINGLES TRIMMED TO COVER FLASHING STRIP "L 4 " FLASHING : Kra APPROVED BUILDING WRAP SHALL BE LAPPED A MINIMUM OF 6' tv VERTICAL LAPS (ROLL ENDS) 4 6' HORIZONTAL LAPS. LATH VERTICAL LAP TO BE 1' METAL LATH TAPE WRB LAYER 1, 5TUCCOWRAP (OR APPROVED EQUAL) DIRECTLY TO SHEATHING I' MIN LATH LAP, 4' OVER ALL LAP VERTICAL LATH & PAPER DETAIL $" THICK, 3 COAT CEMENT PLASTER METAL LATH WRB LAYER #2, FORTIF15ER BUILDING PAPER (OR APPROVED EQUAL) TAPE WRB LAYER 1, 5TUCCOWRAP (OR APPROVED EQUAL) DIRECTLY TO SHEATHING LEGEND DRAINAGE PLANE (WRB LAYER *I, 1. STUCCOWRAP OR "- APPROVED EQUAL) STUCCO WRB LAYER *2 z (FORTIFIBER € BUILDING PAPER OR �I I APPROVED EQUAL) SHEATHING METAL LATH x x x x STUCCO WOOD SHEATHING i//- �///,7 5ELP-ADHE5IVE FLASHING NOTE: METAL LATH: LATH TO BE PER FBC R103.1.1 / ASTM C-841-09, MIN. 2.5 L85. PER SQ. YARD (UTILITY OR NOMINAL LATH DOES NOT MEET SPECIFICATIONS) WRB: WATER RESISTIVE BARRIER A R C H I T E C T S Design Group"Inc 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX:407-774-4078 www.abdesigngroup.com AA N: 0003325 �munni �oaoo�oo, E 8 sVBaiV de LOT: OAKLAND LAKE (LOT #23) MODEL 2195 (VERSION#00) PROJECT#: 2784.000 00023 PAGE: WALL ASSEMBLY DETAILS ARCHRECT= STATE OF FLONDA � v DATE: 5 /7 /18 SC# -LE: 1/4"-1'—O' $' THICK, 3 COAT CEMENT PLASTER STEP PLASHING OVERLAPS KICKOUT DIVERTER I' MIN. STEP FELT UNDERLAYMENT SHINGLE ROOFING DRIP EDGE: OVERLAP 3', EXTEND 1/2' BELOW SHEATHING, MECHANICALLY FASTEN 4" O.C. MAX. NOTE: INSTALL KICKOUT FLASHING AT BOTTOM OF ROOF 4 WALL INTERSECTIONS WRB LAYER 12, FORTIF15ER BUILDING PAPER (OR APPROVED EQUAL) WRB LAYER "I, 5TUCCOWRAP (OR APPROVED EQUAL) TAPED DIRECTLY t0 SHEATHING LAP LAYERS OF BUILDING WRAP OVER NAILING FLANGE, STOP WRB APPROX. 1 Y" ABOVE SHINGLES SELF -ADHERING FLASHING KICKOUT DIVERTER 5 KICKOUT DETAIL ""'~ " �^ nECEIVE I COAT OF 5HER-CRETE ;ONCRETE WATERPROOFER or ,OAT PRIOR TO ELEC. METER ON (PER 3/WAI) ELEC. METER FIELD VERIFY LOCATION ELEC. METER FIELD VERIFY LOCATI APPLY SEALANT At TOP 4 51DES OF ELEC. METER BOX AFTER STUCCO INSTALLATION ELECTRICAL CONDUIT PENETRATION scale: N.Ts. SEALANT ON TOP 4 SIDES ON CAVITY TO BE FILLED WITH RIGID POLYMERIC 150CYANATE-POLY5LEND FOAM ('GREAT STUFF' OR SIMILAR) '—FLASH OPENING WITH PROTECTO FORM FLASH I SELF ADHERING FLASHING PER FLASHING METHOD AS DESCRIBED IN DETAIL 3 OF WA1 'PIPE PENETRATION DETAIL' APPLY I COAT OF 5HER-CRETE PLEX15LE CONCRETE WATERPROOFER 2" LARGER THAN THE ELEC. METER CAN OR METER CAN COMBO OR METER CAN AND DISCONNECT WRB LAYER 1, 5TUCCOWRAP (OR APPROVED EQUAL) WOOD SHEATHING VENT CAP 15 TO BE SET IN CONTINUOUS BED OF SEALANT. ONE -PEKE HOODED VENT ATTACHED PER MANUP. SPECIFICATIONS APPLY SEALANT At PERIMETER OF NON -MOVABLE FRAME AND STUCCO ON ALL SIDES, Y' SEALANT 0 JOINTS ALL AROUND $' THICK, 3 COAT CEMENT PLASTER METAL LATH WRB LAYER 02, FORTIFIBER BUILDING PAPER (OR APPROVED EQUAL) BUILDING PAPER DRYER VENT (FRAME) OVER 'QUICK FLASH 6A sc,,6LE: N.TA PIPE THROUGH WALL TRUCTION SHEATHING WOOD FRAMED WALL HORIZO BUILDING PAPER UNDER 'QUICK FLASH' EVENT PENETRATION ri eckE: Kra WOOD SHEATHING WR5 LAYER "2, FORTIP15ER WRB LAYER I, BUILDING PAPER (OR StUCCOWRAP (OR APPROVED EQUAL) APPROVED EQUAL) IT METAL LATH WRB LAYER 02, WOOD TEXTURED FINISH a WOOD PORTIPIBER CONSTRUCTION FASTEN TO WOOD STRUCTURAL BUILDING PAPER (OR 8" CMU MEMBER ,@ 1' O.C. MAX APPROVED EQUAL) = $ %8' TO V MID -WALL ' THICK, 3 COAT CEMENT ® WEEP SCREED PLASTER 6' WIDE STRIP SELF " TO US' MID -WALL ADHERING FLASHING, CLEAN WEEP SCREED MASONRY BEFORE APPLYING 6' 5ELF-ADHERING FLASHING TEXTURED FINISH 6 MA50NRY ITAL WEEP SCREED HORIZONTAL WEEP SCREED FRAME TO FRAME) � (FRAME TO BLOCK) 1 / Ll E: N.T$. NOTE: PROTECTED FLASH TAPE BEHIND WEEP SCREED 4 APPLY SEALANT AT WEEP SCREED END TO END JOINTS CUT ENOUGH PROTECTO FORM FLASH I PIECES TO COVER BOX 4' PAST EACH SIDE. STARTING AT THE BOTTOM OF THE BOX, REMOVE RELEASE LINER AND APPLY PROTECTO FORM FLASH 1 IN A SINGLE FASHION TO COMPLETELY COVER THE BOX, WOOD SHEATHING WRB LAYER #I, 5TUCCOWRAP (OR APPROVED EQUAL) PROTECTO FORM FLASH I SELF ADHERING FLASHING APPLY 60 MIN GRADE 'D' FELT OVER SELF -ADHERING FLASHING OVER APROVED HOUSEWRAP WRB LAYER 02, FORTIFIBER BUILDING PAPER (OR APPROVED EQUAL) L N lini m STEP 4 NOTE: ATTACH PER MANUP. 5PECIFICATION5 MAKE AN 'X" CUT THROUGH THE PROTECTO FORM FLASH 1 IN THE CENTER OF THE BOX OR OUTLET OPENING EXTENDING TO NO CL05ER THAN I' TO CORNER APPLY E-Z BEAD (OR APPROVED EQUAL) OVER 60 MIN GRADE 'D' FELT -PROVIDE SEALANT AT ALL JOINTS AND INTERSECTIONS TEXTURED CEMENTITIOU5 COATING PREMANUR DRYER VENT CAP (SET IN CONT. SEALANT) SEALANT 9 ALL SIDES 6B DRYER VENT (BLOCK) PER FBC R103.1.1 EXTERIOR LATHING AND PLASTERING EXTERIOR USE OF PORTLAND CEMENT PLASTER SHALL COMPLY WITH THE APPLICATION REQUIREMENTS OF ASTM C 926-12A. INSTALLATION OF EXTERIOR LATHING AND FRAMING SHALL COMPLY WITH ASTM C 1063-12A . o.o.o. e .e.e.00 0 •O •• o. o e .o . c. .o e e. o. .o .e e. o. e .o o. 0 .o.e.e.e STEP 5 LEGEND DRAINAGE PLANE (WRB LAYER 1, STUCCOWRAP OR APPROVED EQUAL WRB LAYER 02 (FORTIFIBER BUILDING PAPER OR APPROVED EQUAL) METAL LATH X X X X STUCCOg WOOD SHEATHING SELF-ADHESIVE FLASHING NOTE: METAL LATH: LATH TO BE PER FBC R103.1.1 / ASTM C-84i-09, MIN. 25 L55. PER SQ. YARD (UTILITY OR NOMINAL LATH DOES NOT MEET SPECIFICATIONS) PUSH THE PROTECTO FORM FLASH I INTO THE OPENING AND ADHERE TO THE INTERIOR OF THE BOX. ELASTOMERIC COATING (OR APPROVED EQUAL) OVER STUCCO/ C.V. FIN15H (SEE TYPICAL WALL SECTION) METAL LATH EXTERIOR (-,`� ELECTRICAL RECEPTACLE Sli nlidl FP R A R C H I T E C T S 1441 K. KUKALU KCAUAK 6LVU. LONGWOOD, FL 32750 PH: 407-774-6078 FAX:407-774-4078 www.abdesigngroup.com AA #: 0003325 r � �IIIIIIIIII LPemm000mvog E 8 4D O c L"s, sv$Drv. LOT: OAKLAND LAKE (LOT #23) MODEL: 2195 (VERSION#00) PROJECT*: 2784.000/00023 PAGE: WALL ASSEMBLY DETAILS ARCHrrECT: STATE OF FLORIDA DATE:,, 6/7/18 sCAI E• 1/4"=1'-0" WOOD SHEATHING WOOD CONSTRUCTION %' HAT CHANNEL W/ V TYPE 'X' DRYWALL WOOD SHEATHING WRB LAYER 1, - STUCCOWRAP (OR APPROVED EQUAL) $' THICK, 3 COAT — CEMENT PLASTER WRB LAYER'�l, STUCCOWRAP (OR APPROVED EQUAL) AMIGO AM66-WFWC-180 CUSTOM CASING BEAD (OR APPROVED EQUAL) DO NOT CAULK OR SEAL GAP WRB LAYER �, STUCCOWRAP (OR APPROVED EQUAL) WRB LAYER 12, FORTIF15ER BUILDING PAPER (OR APPROVED EQUAL) ' THICK, 3 COAT CEMENT PLASTER AM66-WFWC-180 CUSTOM CASING BEAD (OR APPROVED EQUAL) WRB LAYER M, 5TUCCOWRAP (OR APPROVED EQUAL) WRB LAYER #2, FORTIFIBER BUILDING PAPER (OR APPROVED EQUAL) II 6' SELF-ADHEREING FLASHING Z WRAPPED m CORNER OF CANTILEVER x MR W AMIGO AM66-9WC-180 CUSTOM CASING BEAD (OR APPROVED EQUAL) (W/OPT. WEEPS) CASING BEAD DETAIL CANT. FIN15H LAYER (2 LAYER PEEL 4 STICK) 6' PEEL 4 STICK 9 DRIP EDGE TO DECK 1 Y'XI Y4' P.T. OR 51MULATED WOOD (TREX) FILLER (OR APPROVED EQUAL), CONTINUOUS WATER PROOFING 1st LAYER (2 LAYER PEEL 4 STICK) WRAPPED FROM BALCONY DECK TO CANTILEVER 6' PEEL 4 STICK is DRIP EDGE TO DECK SUB FLOOR FULL SHEETS OF PEEL 4 STICK I Y2"X1 Y4' P.T. OR 51MULATED WOOD (TREX) FILLER (OR APPROVED EQUAL), CONTINUOUS Y' GAP FOR BACKER ROD 4 SEALANT ' THICK, 3 COAT CEMENT PLASTER VINYL (OR APPROVED EQUAL) CASING BEAD VINYL (OR APPROVED EQUAL) BEAD VINYL (OR APPROVED EQUAL) CASING LEGEND DRAINAGE PLANE (WRB LAYER 1, STUCCOWRAP OR APPROVED EQUAL WRB LAYER *2 (FORTIF15ER BUILDING PAPER OR APPROVED EQUAL) METAL LATH X X X X STUCCO WOOD SHEATHING 5ELF-ADHESIVE FLASHING EQUAL) CASING BEAD 5/8' TYPE "X' DRYWALL W/TEXTURED 4 PAINTED FINISH ' THICK, 3 COAT CEMENT PLASTER VINYL (OR APPROVED EQUAL) CORNER BEAD VINYL (OR APPROVED EQUAL) CASING BEAD 3" X 3" 2ta GA. GALV. METAL DRIP EDGE SET IN FULL BED OF SEALANT, Y' MIN. SPACE FROM DRIP FACE TO TREX Y' GAP FOR BACKER ROD 4 SEALANT ' WEATHER RESISTIVE BARRIER 01 **,COMPONENTS PULLED WEATHER RESISTIVE BARRIER02 APART CLARITY DECK MEMBRANE, EXTEND OVER DRIP EDGE 3" X 3" 26 GA. GALV. METAL DRIP EDGE SET IN FULL BED OFI SEALANT, V MIN. SPACE FROM NOTE: METAL LATH: LATH TO BE PER FBC R103.1.1 / ASTM C-841-091 MIN. 2.5 L55. PER SQ. YARD (UTILITY OR NOMINAL LATH DOES NOT MEET SPECIFICATIONS) WOOD CONSTRUCTION WEATHER RESISTIVE BARRIER I WEATHER RESISTIVE BARRIER *2 $' THICK, 3 COAT CEMENT PLASTER METAL LATH WOOD SHEATHING HEADER/BEAM VINYL CORP. (OR APPROVED EQUAL) 4'_10051TIVE DRAIN WEEP SCREED NO GAP IN FIELD (SHOWN FOR CLARIFICATION OF SEPARATE ACCESSORIES ONLY) 11A MRDRIP EDGE INSTALLATION : KT.6. -- ,V' GAP FOR BACKED` ROD 4 SEALANT VINYL (OR APPROVED EQUAL) CASING BEAD WATER PROOFING Ist LAYER (2 LAYER PEEL 4 STICK) PEEL 4 STICK SUB FLOOR DRIP FACE TO TREX MODIFIED 90 VINYL (OR APPROVED EQUAL) CA51NG E WATER PROOFING 1st LAYER (2 LAYER PEEL 4 STICK) WRAPPED FROM BALCONY DECK TO CANTILEVER THICK, 3 COAT CEMENT PLASTER METAL LATH WOOD SHEATHING WEATHER RESISTIVE BARRIER "1 WEATHER RESISTIVE BARRIER 02 4' P051TIVE DRAIN WEEP SCREED NO GAP IN FIELD (5HOiUN FOR CLARIFICATION OF SEPARATE ACCESSORIES ONLY) , ;BALCONY DRIP EDGE INSTALLATION 1 1 D Kta -- 1 Y2'XI V P.T. OR SIMULATED WOOD (TREX) FILLER (OR APPROVED EQUAL), CONTINUOUS Y4" GAP FOR SEALANT 4 OPT. BACKER ROD ossCOMPONENT5 PULLED APART FOR CLARITY 8" THICK, 3 COAT CEMENT PLASTER VINYL (OR APPROVED EQUAL) CA51NG BEAD VINYL (OR APPROVED EQUAL) BEAD VINYL (OR APPROVED EQUAL) CASING BEAD NOTE: SET RAILING LAG BOLT ATTACHNMENTS IN SEALANT, WHERE APPLICABLE 2x FRAMING MEMBER s' THICK, 3 COAT CEMENT PLASTER CORNER BEAD FASTENED TO SHEATHING e 1' O.C. MAX. WRB LAYER 1, STUCCOWRAP (OR APPROVED EQUAL) WOOD SHEATHING METAL LATH JL WRB LAYER *2, FORTIF15ER BUILDING PAPER (OR APPROVED EQUAL) @-AQCORNER BEAD ® FRAME CORNER BEAD (FASTENER 4 SPACING i' O.G.) CMU W THICK, 3 COAT CEMENT PLASTER APPLIED DIRECTLY TO CONCRETE MASONRY UNIT SCORNER BEAD ® BLOCK 1(r D SCALE: KT& COLUMN SHEATHING WEATHER RESISTIVE BARRIER M WEATHER RESISTIVE BARRIER *2 6" SELF ADHERING 4 FLASHING PEEL 4 STICK 1 X2"x3' V' FLASHING FULLY EMBEDDED IN ROOF CEMENT 1 Y" X 3" 26 GA. GALV. METAL DRIP EDGE SET IN FULL BED OF 5EALANT, V MIN. SPACE FROM DRIP FACE TO TREX WEATHER RESISTIVE BARRIER "1 WEATHER RE515TIVE BARRIER #2 EXTERIOR COLUMN COLUMN SHEATHING 6" SELF ADHERING 4 FLASHING 1 Y2°x3' V' FLASHING FULLY EMBEDDED IN ROOF CEMENT Y2' X 3' 26 GA. GALV. METAL DRIP EDGE SET IN FULL BED OF SEALANT, Y' MIN. SPACE FROM DRIP FACE TO TREX ON ALL 4 SIDES OF COLUMN VINYL (OR APPROVED EQUAL) CASING BEAD WATER PROOFING let LAYER (2 LAYER PEEL 4 STICK) WRAPPED FROM BALCONY DECK TO CANTILEVER 8' THICK, 3 COAT CEMENT PLASTER METAL LATH -WOOD SHEATHING WEATHER RE515TIVE BARRIER *1 WEATHER RE515TIVE BARRIER "2 4' P051TIVE DRAIN WEEP SCREED NO GAP IN FIELD (SHOWN FOR CLARIFICATION OF SEPARATE ACCESSORIES ONLY) BALCONY DRIP EDGE INSTALLATION ® COLUMN W/ 'T' FLASHING A R C H I T E C T S 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX:407-774-4078 www.abdesigngroup.com AA N: 0003325 r � �IIIIIIIIII Liem000u0oaj SUBDIV. & LOT: OAKLAND LAKE (LOT #23) MODEL: 2195 (VERSION#00) PROJECT*: 2784.000 00023 PAGE: WALL ASSEMBLY DETAILS 3TATEA F"rLCDA 1 5/7/18 1 9CAt.E: 1/4" =1'-0" 1 WOOD SHEATHING WRB LAYER *I, 5TUCCOWRAP (OR APPROVED EQUAL) WRB LAYER 02, FORTIF15ER BUILDING PAPER (OR APPROVED EQUAL) METAL LATH J' THICK, 3 COAT CEMENT PLASTER 6 "SELF -ADHERING FLASHING WINDOW FLANGE WRB LAYER *1, 5TUCCOWRAP (OR APPROVED EQUAL) WRB LAYER *2, FORTIF15ER BUILDING PAPER (OR APPROVED EQUAL) METAL LATH $" THICK, 3 COAT CEMENT PLASTER 6' 5ELF-ADHERING FLASHING DRIP CAP WINDOW FLANGE CASING BEAD @ WINDOW wwwz FRAME, NOBAND N,TA WRB LAYER *I, 5TUCCOWRAP (OR APPROVED EQUAL) WOOD SHEATHING WR5 LAYER *2, FORTIF15ER BUILDING PAPER (OR APPROVED EQUAL) METAL LATH cExP!_cvm) i" THICK, 3 COAT VIEW FOR CEMENT PLASTER CLARITY) WOOD CONSTRUCTION BEYOND WOOD SHEATHING WEATHER RE515TIVE BARRIER I WEATHER RESISTIVE BARRIER *2 X 7 Y4" LAP 51DING W/6" REVEAL 6' 5ELF-ADHERING FLASHING STARTER STRIP PER MANUFACTURER'S INSTALLATION — IN5TRUCTION6 DO NOT CAULK OR SEAL OPENING GALV'D METAL 'Z' FLASHING STUCCO CA51NG BEAD 1111111filifill SIDING TO STUCCO ® BLOCK TO FRAME TRANSITION WOOD SHEATHING WEATHER RE515TIVE BARRIER I WEATHER RE515TIVE BARRIER *2 " X i Y4' LAP SIDING W/6 REVEAL 6' SELF -ADHERING FLASHING STARTER STRIP PER MANUF� INSTALLATION IN5TRUCTION5 DO NOT SEAL OPENING GALV'D METAL "Z' FLA5HING E-Z BEAD VINYL (OR APPROVED EQUAL) CA51NG (W/%s" FLEXIBLE PVC BACKER ROD) 6' SELF -ADHERING FLASHING Yell THICK, 3 COAT CEMENT PLASTER WEATHER RESISTIVE BARRIER *1 WEATHER RE515TIVE BARRIER *2 WOOD SHEATHING WRB LAYER I'I, 5TUCCOWRAP (OR APPROVED EQUAL) WRB LAYER *2, FORTIF15ER BUILDING PAPER (OR APPROVED EQUAL) METAL LATH J' THICK, 3 COAT CEMENT - PLA5TER WOOD SHEATHING ___l WRB LAYER *1, 5TUCCOWRAP (OR APPROVED EQUAL) x WRB LAYER *2, FORTIF15ER BUILDING PAPER x (OR APPROVED EQUAL) ANGLED CA51NG BEAD METAL LATH 6'SELF-ADHERING FLASHING tExPLFOR J' THICK, 3 COAT VIEW FOR \ CEMENT PLASTER DRIP GAP; CLARITY) WINDOW FLANGE WRB LAYER I'I*I, 5TUCCOWRAP (OR APPROVED EQUAL) VINYL (OR APPROVED EQUAL) ANGLED CA51NG BEAD WRB LAYER *2, FORTIF15ER BUILDING PAPER (OR APPROVED EQUAL) METAL LATH J' THICK, 3 COAT CEMENT PLASTER b'SELF-ADHERING FLASHING DRIP CAP CASING I EAD @ WINDOW WINDOW FLANGE 3B (FRAME, W/ BAND 6' SELF -ADHERING FLASHING WEATHER RE515TIVE BARRIER #I WEATHER RESISTIVE BARRIER 02 STARTER STRIP PER MANUFACTURER'S INSTALLATION ' INSTRUCTIONS 6' 5ELF-ADHERING FLASHING GALV'D METAL "Z' FLA5HING DO NOT CAULK OR SEAL OPENING ,`=—GALV'D METAL "Z' FLiASNING WOOD CONSTRUCTION 6' SELF -ADHERING FL WEATHER RESISTIVE BARRIER *1 TO LAP 6' MIN. ABOVE TOP OF "Z' LASHING WEATHER RESISTIVE BARRIER I WEATHER RE5ISTIVE BARRIER *2 .. GALV'D METAL 'Z' FLA5HING DO NOT CAULK OR SEAL OPENING WEATHER RESISTIVE BARRIER M TO LAP 6' MIN. ABOVE TOP OF 'Z' FLA5HING — 6' SELF -ADHERING FLASHING WEATHER RE51STIVE BARRIER I —E-Z BEAD VINYL (OR APPROVED EQUAL) CASING (W/YS' FLEXIBLE PVC BACKER ROD) — WEATHER RESISTIVE BARRIER *2 SIDING TO STUCCO FRAME TO FRAME TRANSITION V OCL+LE: KTA LEGEND DRAINAGE PLANE (WRB LAYER *1, STUCCOWRAP OR APPROVED EQUAL) WRB LAYER *2 (FORTIF15ER BUILDING PAPER OR APPROVED EQUAL) METAL LATH X X X X STUCCO WOOD SHEATHING // Zi SELF-ADHESIVE FLASHING NOTE: METAL LATH: LATH TO BE PER FBC R103.1.1 / A5TM C-841-09, MIN. 2.5 L55. PER SQ. YARD (UTILITY OR NOMINAL LATH DOES NOT MEET SPECIFICATIONS) rWALANT— WINDOW FRAME WINDOW FLANGE 2X FRAMING MEMBER BUILDING 4 GAP rrP ASW3 9WAD ro wNoou $' THICK, 3 COAT CEMENT y4 GAP PLASTER CATO TRIM METAL LATH IX TRIM MEMBER m STUCCO ro l eirr TO SIDING TRANSITION WRB LAYER 02, FORTIF15ER 51DING BUILDING PAPER (OR APPROVED EQUAL) WOOD SHEATHING WRB LAYER *I, 5TUCCOWRAP (OR APPROVED EQUAL) SIDING TO STUCCO CASING BEAD gRai. Kra r aaoee-eEcriow WOOD SHEATHING METAL LATH WRB LAYER *I, 5TUCCOWRAP (OR APPROVED EQUAL) WRB LAYER *2, FORTIF15ER BUILDING PAPER (OR APPROVED EQUAL) J' THICK, 3 COAT CEMENT PLASTER VINYL (OR APPROVED EQUAL) $' THICK, 3 COAT CEMENT PLASTER ANGLED CASING BEAD VINYL (OR APPROVED EQUAL) CASING BEAD WRB LAYER *I, 5TUCCOWRAP (OR APPROVED EQUAL) CASING BEAD 6' SELF ADHERING FLASHING OR PEEL 4 STICK WOOD SHEATHING WRB LAYER *I, STUCCOWRAP k (OR APPROVED EQUAL) S-WRB LAYER 02, FORTIF15ER >t BUILDING PAPER (OR APPROVED EQUAL) METAL LATH $' THICK, 3 COAT CEMENT (EXPLODED PLASTER i VIEW FOR CLARITY) CASING BEAD @ RAISED BAND FRAME 1 J SCALE: N.ra METAL LATH SEALANT WRB LAYER *2, FORTIF15ER BUILDING PAPER (OR APPROVED EQUAL) WOOD SHEATHING WINDOW FRAME—\ 4 \--WRB LAYER *I, 5TUCCOWRAP (OR APPROVED EQUAL) 6' WIDE PEEL 4 STICK OVER FLANGE E-Z BEAD VINYL 2X FRAMING (OR APPROVED EQUAL) CA51NG (W/ FLEXIBLE PVC BACKER ROD MEMBER INCLUDED) *APPLY FULL RED OF SEALANT BETWEEN FLANGE 4 BUILDING WRAP 'EZ BEAD WINDOW CASING 17 �: Krs�: Krs. $' THICK, 3 COAT CEMENT PLASTER METAL LATH — WRB LAYER 02, FORTIF15ER BUILDING PAPER (OR APPROVED EQUAL) — E-Z BEAD VINYL (OR APPROVED EQUAL) CASING (W/Ya' FLEXIBLE PVC BACKER ROD INCLUDED) — WRB LAYER *I, 5TUCCOWRAP (OR APPROVED EQUAL), WRAPPED AROUND FRAMING MEMBER / 6' SELF ADHERING FLASHING — WOOD SHEATHING DETAIL EXPLODED FOR CLARITY A R C H I T E C T S i44i n. NUNA{ U KCAwAly owU. LONGWOOD, FL 32750 PH: 407-774-6078 FAX:407-774-4078 www.abdesigngroup.com AA #: 0003325 r � �ovvovv000, sysDxv. ai: LOT: OAKLAND LAKE (LOT #23) MODEr • 2195 (VERSION#00) PROJECT#: 2784.000/00023 PAGE: WALL ASSEMBLY DETAILS ARCHITECT: STATE OF FLORIDA Y D �E: 5/7/18 S ALE:1/4"=1'—O" SHEE�Tr T V V 4 F t CUT HOU5EWRAP AT 450 ANGLE MODIFIED "I" CUT IN HOU5EWRAP LINE OF WINDOW OPENING APPROVED HOUSEWRAP OVER SHEATHING OVER WD STUD WALL STEP I WINDOW FLASHING INSTALLATION DETAILS FULL WRAP t u aca NTA (FRAME) WALL FLASH SA gy_p LT DETAIL G INST. TION TEMPORARILY FOLD -UP t SECURE HOUSEWRAP (OR _. , _, . _, • P UNDER) at HEAD FOLD HOU5EWRAP IN AT JAM55 8 SILL SLOPE SILL RO. TO EXTERIOR INSTALL b" SELF -ADHERING FLASHING OVER NAILING FLANGE AT JAMBS EXTEND FLASHING MIN I" BELOW SILL FLEXIBLE FLASHING DO NOT SEAL BOTTOM FIN APPLY OSI 142U (OR EG IAL) SEALANT • WINDOW/CMU JOINT. FLUID APPLIED FLAB 41N4 (LANCO WHITE -SEAL RC-e65, OR Eau&). ALIGN FLEXIBLE SELF -ADHERING FLASHING W/ INT, EDGE OF SILL R.O. MECHANICALLY FASTEN FANNED EDGES. (CAP NAILS, STAPLES) STEP 2 INSTALL SELF -ADHERING STEP 3 FLEXIBLE FLASHING AS THE FLASHING AT THE SILL INSTALL V SELF -ADHERING FLASHING OVER VINYL HEAD FLASHING (WITH END DAMS) NAILING FLANGE SELF -ADHERING FLASHING I' MIN BEYOND JAMB FLASHING INSTALL VINYL DRIP CAP STEP 61 _�w STEP 7 SLOPE SILL TO EXTERIOR APPLY 3/a" NOM. CONTINUOUS BEAD OF SEALANT AT JAMBS AND DEAD or APPLY TO BACK OF WINDOW NAILING FLANGE IN LINE W/ PRE -PUNCHED HOLES OR SLOTS. SUPER STRETCH BUTYL FLASHING V VERT. END DAMS REQ'D. AT EACH END OF SILL FOLD HOU5EWRAP DOWN E TAPE DIAGONAL CUT 4 ACROSS HEAD OF WINDOW STEP 4 STEP 8 INSTALL A SILL DAM OVER THE BUILDING WRAP AT THE BACK OR THE SILL AND THEN INSTALL THE SELF -ADHERING STRETCHABLE FLASHING 4 APPLY SEALANT AT ENDS OF SILL DAM INSTALL WINDOW PILL LEVEL AND SQUARE I MANUFACTURERS WRIT IN5TRUCTI APPLY MEMBRANE FLASHING OVER JOINT INSTALL b" WIDE ADHESIVE BACKED FLEXIBLE FLASHING MATERIAL OVER DRIP CAP JOINT (PROTECTO-WRAP 5T-20XL \\ OR APPROVED EQUAL) STEP 5 STEP 9 NOTE: 1. IT 15 THE CONTACTORS RE5PON515ILTY TO VERIFY THE COMPATIBILITY OF ALL PRODUCTS INCLUDING HOU5EWRAP, 5EALANT5 4 5ELF-ADHERING FLASHING MATERIALS USED DURING CONSTRUCTION. 2. INSTALL ALL MATERIALS PER MANUFACTURERS WRITTEN SPECIFICATIONS 4 WARRANTY REQUIREMENTS. WARNING: SEALANTS AND SELF ADHERED FLASHING MAY REACT ADVERSELY IF NOT COMPATIBLE. NOTE: SEAL INTERIOR PERIMETER OF WINDOW WITH SEALANT A R C H I T E C T S Design t'OU Inc. 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX:407-774-4078 www.abdesigngroup.com AA #: 0003325 �III"IIIII L ovvvov000� s 'w •► swHDry x oT. OAKLAND LAKE (LOT #23) MODEL 2195 (VERSION#00) PROJECT#: 2784.000/00023 PAGE: WALL ASSEMBLY DETAILS AROI' , CCT: STATE OF FLORDA s/7/18 E. iMt] A5