Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD CALCULATIONSCANNED Planning &Development Services Department BY Building & Code Regulations Division St Lucie County 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 e Certification for Design Load Compliance Project Name: Mr & Mrs Project Address: XXXX Sneed Rd Fort P Permit #: , FL 34945 Occupancy Type: R-3 Construction Type: VB INSTRUCTIONS FOR USE: • This certification must be completed, signed, a • Submit (2) copies for residential, (3) copies for o New Residences (single or multi-famil o Residential Addition o Any accessory structure requiring a bi o Any non-residential structure. * Note: Form not required for interior renovation certain minor building permits at the discretion of sealed by the design professional of record. nmercial with all permit applications involving the following: Iding permit provided that no exterior structural elements are affected and ie local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: I (complete all that apply) 1. DESIGN CODE: Florida 6th Edition Cod Fifth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: _I X II III I Exposure Category: B X C D 4. Design Wind Velocity 160 mph 1 24ASD LRFD End Zone Width: 3 ft ; 5. Mean Roof Height 15 ft I Roof Pitch: 5 :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: 32/51 Zone 2: 32189 Zone 3:I 32/131 Zone 4: 56/61 Zone 5: 56/75 Garage: 56/75 7. Design Loads: Floor: PSF Roof/ �Dead: 25 PSF Roof/Live: 30, Balcony: PSF Dock: PSF Deck: PSF Stair's: PSF Fence: PSFi Railings: PSF ' 8. Were Shear Walls Considered For Structure?I Yes Not Applicable Explain Why Not: A . 9. Is A Continuous Load Path Provided? X Y�s Not Applicable Explain Why Not: r 10. Design Soil Bearing Pressure: 2500 PSIF Soil Test Reports Submitted? Yes I certify that, to the best of my knowledge and Ibelief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design Lillian Gonzalez Sri t Name Goarch EnaineerinQ, Inc 79442 Cert # & Co. Cert Auth. Luoui Ct West Palm Beach, FL 33415 any Name & Address File COPY