HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD CALCULATIONSCANNED
Planning &Development Services Department BY
Building & Code Regulations Division St Lucie County
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
e
Certification for Design Load Compliance
Project Name: Mr & Mrs
Project Address: XXXX Sneed Rd Fort P
Permit #:
, FL 34945
Occupancy Type: R-3 Construction Type: VB
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, a
• Submit (2) copies for residential, (3) copies for
o New Residences (single or multi-famil
o Residential Addition
o Any accessory structure requiring a bi
o Any non-residential structure.
* Note: Form not required for interior renovation
certain minor building permits at the discretion of
sealed by the design professional of record.
nmercial with all permit applications involving the following:
Iding permit
provided that no exterior structural elements are affected and
ie local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: I (complete all that apply)
1. DESIGN CODE: Florida 6th Edition Cod Fifth Edition with 20 17 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed Partially Enclosed Open
3. Risk Category: _I X II III I Exposure Category: B X C D
4. Design Wind Velocity 160 mph 1 24ASD LRFD End Zone Width: 3 ft ;
5. Mean Roof Height 15 ft I Roof Pitch: 5 :12 Parapet: ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: 32/51 Zone 2: 32189 Zone 3:I 32/131 Zone 4: 56/61 Zone 5: 56/75 Garage: 56/75
7. Design Loads: Floor: PSF Roof/ �Dead: 25 PSF Roof/Live: 30, Balcony: PSF
Dock: PSF Deck: PSF Stair's: PSF Fence: PSFi Railings: PSF '
8. Were Shear Walls Considered For Structure?I Yes Not Applicable Explain Why Not: A
. 9. Is A Continuous Load Path Provided? X Y�s Not Applicable Explain Why Not:
r 10. Design Soil Bearing Pressure: 2500 PSIF Soil Test Reports Submitted? Yes
I certify that, to the best of my knowledge and Ibelief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
Lillian Gonzalez
Sri t Name
Goarch EnaineerinQ, Inc
79442
Cert # & Co. Cert Auth.
Luoui Ct West Palm Beach, FL 33415
any Name & Address
File COPY