I
TRIANGLE TESTING LAB, INC.
SCANNED CoA#3101
BY 4750 ROYAL PALM BEACH BOULEVARD
St Lucie County WEST PALM BEACH, FLORIDA 33411
(561)790-3049
e-mail: tr6gIe2992C-)nmail.com
Date: June 26, 2018
To: Saint Lucie County Building Department
Re: Soil Compaction Report -Dent ity of In -Place Compacted Soil
SYNERGY HOMES - RESIDENCE
19601 KELLY ROAD
FORT PIERCE, FL
RECEIVED
JUL 6.5 2010 .
Permitting Deparoneat
St Lude Ctmamft
Test Date
Test #
Test Location
Elevation
In -Place Readings
MMPD Values
%
Density
Moisture
Density
Moisture
06/22/18
1
Southeast Area
1'-2'
108.3
8.6
109.5
5.6
98.9
06/22/18
2
Center Area
0-1'
107.2
9.2
109.5
5.6
97.9
06/22/18
3
Northwest Area
1'-2'
108.5
8.4
109.5
5.6
99.1
Remarks: All elevations are measured from top iof pad grade. (Mod Proctor Test #1)
Verification Statement
This statement shall serve as verification that the sdil beneath the proposed structure has been tested in accordance
with Section R401.4 of the 2017 Florida Building Code, Residential edition. The tests were conducted from the
existing grade.
Density tests were taken at a minimum of three (3) locations throughout the total depth of fill. The depth of fill was
approximately 4.0 feet. The foundation setbacks were based on information furnished by the client, at the time of
testing.
Based on the location and depths tested, we verify
maximum dry density as determined by ASTM D-1
foundation area is 2,500 pounds per square foot.
Respectfully submitted,
Ric4ard Boyette, FL PE #42485
Vice President
June 26, 2018
File # 20758
the fill has been compacted to a minimum of 95% of the
and that the minimum soil bearing value beneath the proposed
�G '" •. FTC.
STATE OF
IOP'��Q
AL
i
JUL 0 9 2018