Loading...
HomeMy WebLinkAboutCOMPACTION REPORT• n i I TRIANGLE TESTING LAB, INC. SCANNED CoA#3101 BY 4750 ROYAL PALM BEACH BOULEVARD St Lucie County WEST PALM BEACH, FLORIDA 33411 (561)790-3049 e-mail: tr6gIe2992C-)nmail.com Date: June 26, 2018 To: Saint Lucie County Building Department Re: Soil Compaction Report -Dent ity of In -Place Compacted Soil SYNERGY HOMES - RESIDENCE 19601 KELLY ROAD FORT PIERCE, FL RECEIVED JUL 6.5 2010 . Permitting Deparoneat St Lude Ctmamft Test Date Test # Test Location Elevation In -Place Readings MMPD Values % Density Moisture Density Moisture 06/22/18 1 Southeast Area 1'-2' 108.3 8.6 109.5 5.6 98.9 06/22/18 2 Center Area 0-1' 107.2 9.2 109.5 5.6 97.9 06/22/18 3 Northwest Area 1'-2' 108.5 8.4 109.5 5.6 99.1 Remarks: All elevations are measured from top iof pad grade. (Mod Proctor Test #1) Verification Statement This statement shall serve as verification that the sdil beneath the proposed structure has been tested in accordance with Section R401.4 of the 2017 Florida Building Code, Residential edition. The tests were conducted from the existing grade. Density tests were taken at a minimum of three (3) locations throughout the total depth of fill. The depth of fill was approximately 4.0 feet. The foundation setbacks were based on information furnished by the client, at the time of testing. Based on the location and depths tested, we verify maximum dry density as determined by ASTM D-1 foundation area is 2,500 pounds per square foot. Respectfully submitted, Ric4ard Boyette, FL PE #42485 Vice President June 26, 2018 File # 20758 the fill has been compacted to a minimum of 95% of the and that the minimum soil bearing value beneath the proposed �G '" •. FTC. STATE OF IOP'��Q AL i JUL 0 9 2018