Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE1 , FORM R405--2017 FLORIDA. ENERGY EFFICIENCY CODE FOR- BUILDING CONSTRUCTION Florida Department of' Business and Prof ssional Regulation - Residential Performance Method Project Name: FYC-Baxley Builder Name: FY Construction, LLC Street:' Sneed' Rd Permit. Office: City, State, Zip: : . Fort Pierce , FL , 33945 '. ��A�NE Permit Number_: Owner: FY Construction, LLC BY Jurisdiction: Design Location: FL, Fort Pierce _ Co •� ntY County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2449.1 sgft.) Insulation . Area 2. Single family.or multiple.family. Single family a. Concrete Block - Int Instil, Exterior R=6.0 216920 ft2 b. Frame - Wood, Adjacent R=13.0 279.90 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 10. Ceiling Types (2819.0 sgft.) Insulation Area & Is this a worst case? No a. Roof Deck (Unvented): R=20.0 2819:Oo ft2 6. Conditioned floor area above grade (ft2) 2819.21508789 b. N/A R_ ft2 Conditioned floor area below grade (ft2) 0. c. N/A R= ft2 11. Ducts R ft2 7. Windows(296.3 -sgft.) Description Area a. Sup: Whole House, Ret: Whole House, AH: Whol 6 563.84 a. U Factor: Dbl; U=0:30 218.28 ft2 SHGC: SHGC=0.21 b. U-Factor: Dbl,-U=0.25 48.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0:78 a. Central Unit 34.8 SEER:16.00 c. U-Factor: Dbl,-U=0.36 12.00 ft2 SHGC: SHGC=0.24 13. Heating systems kBtu/hr Efficiency d. U-Factor. other.(see details) 18.00 ft2. a. Electric Strip Heat 31:0 COP:1.00 SHGC: other (see details) Area Weighted Average Overhang Depth: 4.993 ft: Area Weighted Average SHGC:: 0.209 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2819.0 sgft.) Insulation Area EF: 0.920 a. Slab -On -Grade Edge Insulation R=0:0. 2819.00. ft2. b. Conservation features b. N/A. R= ft2 None c., N/A R= ft2 - 15. Credits Pstat Total Proposed N�odified Glass/Floor Area: 0.105 Loads: 85.43 Total Baseline Loads:. 85.48.PASS I hereby certify that the plans and. specifications covered by Review of the plans and .2K1iE ST,q?, this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance �, n„� i'-' with the Florida Energy Code; 1L PREPARE BY DATE: s�/f Before construction is completed .. this building will be inspected for �. y compliance with Section 553.90.8. Florida Statutes: ✓�. I hereby certify that this building, as designed, is in compliance 6� with the Florida Energy �Code: OWNER/AGENT:. BUILDING OFFICIAL: DATE:/��1 i DATE: Compliance requires certification by'the air handier unit manufacturer that the air handler enclosure qualifies'as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation inspection Checklist in accordance with 0402.4.1.1 and this project requires an envelope leakage test report with envelope leakage, no greater than 4.00 ACH50 (R402.4.1:2). File .Cop 5/30/2018 4-1&PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 5 J 1=nRnn Rangy-gn17 INPUT SUMMARY .CHECKLIST REPC)RT PROJECT Title:. Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: FYC-Baxley User FY Construction, LLC 1 FY Construction, LLC Single-family New (From Plans) Bedrooms: Conditioned Total Stories: Worst Case: Rotate Angle: Cross Ventilation: Whole House.Fan: 4 Area: 2819 1 No 0 Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: Sneed Rd County: St. Lucie City, State, Zip: Fort Pierce , FL, 33945 CLIMATE / Design Location TMY Site Design Temp 97.5 %. 2.5 % Int Design Temp Heating. Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce . FL_VERO_BEACH_MUNI 39 90, 70, 75. 299 62 Low BLOCKS Number Name 'Area Volume 1 Blockl 2819.21.5 26303.3 I SPACES Number Name Area Volume K tchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Whole House 2819.215 26303.3 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Whole House 265 0 2819 ft2 ---- . 0.75 0 0.25 ROOF V # Roof Type Materials Area Gable Roof Area Color Solar Absor. . SA Emitt Emitt Deck Tested Tested . Insul. Pitch (deg) 1 Hip Composition shingles 3053 ft2 0 ft2 Medium. 0.85 No 0.9 No 20 22.6 ATTIC, V' # Type Ventilation (Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2819 ft2 i N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Whole House 0 Blown i 2819 ft2 0.11 Wood i 5/30/2018 4:18 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMAR i CHECKLIST REPORT WALLS Adjacent Space Cav1.ity Width Height Sheathing Framing Solar Below 1 S Exterior Concrete Block-.Int InsWhole House 6 15 0 .9.33 0 130.9 ft2 0 0 .0.8 0 -2- E Exterior Concrete Block,- Int InsWhole House 6. 20 0 9.33 0 , 186.6 ft2 0. 0 . 0.8 . 0 3 .. E Exterior . Concrete Block - Int InsWhole. House 6 14 0 9.33 0 .130.6 ft2 0 0 0.8 0 4 N Exterior' Concrete Block - Int InsWhole House 6 15 0 9.38 . 0. 139.9.ft2 0 0. 0.8 0 5 W Exterior Concrete Block - Int InsWhole House 6 15 0 9.33 0 139.9.ft2 0 0 0.8 0 6 E Exterior. Concrete Block ­Int InsUl/hole House 6 9.5 0 9.33 . 0 88.6 ft2. 0 0 0.8 0 7 E Exterior .Concrete Block - Int InsWhole House 6- 3 0 9.33 0 28.0 ft2 0 0 0.8 0 8 N Exterior Concrete Block - Int InsWhole House 6 16 0 9.33 0 149.3 ft2 0 0 0.8 0 9 E Exterior , . Concrete Block - Int InsUVhole House 6 . 3.67 0- 9.33 0 34.2 ft2. .0 0 . 0.8 0 10 N Exterior . Concrete Block - Int InsUI/hole House .6 7.5 0 9.33 0 70.0 ft2 0 0 0.8 0 11 . S Exterior Concrete Block.- Int InsWhole House 6. 16 0 9.33 0 149.3 ft2 0 0 0.8 0 12 S Exterior Concrete Block - Int InsWhole House 6 12.33 0 9.33 0 115.0 ft2 0 0 0.8 0 13 E Exterior Concrete Block - Int InsWhole House 6 11 0 9.33 0 102.6 ft2. 0 0 0.8 0 14 S Exterior. Concrete Block ° Int InsUl/hole House 6 9.5 - 0 9.33- 0. 88.6 ft2 0 0 0.8 0 15 E Exterior Concrete Block- Int InsWhole. House 6 5.5 0 9.33 . 0 51.3 ft2. 0 0 0.8 0 . 16 W Exterior - Concrete Block - Int InsWhole House 6 12 0 9.33 0 1.12.0 ft2 .0 0 0.8 0 17 - S Exterior Concrete Block - Int InsWhole: House 6 7 0 9.33 0 65.3 ft2 0 .0 '0.8 0 18 W Exterior Concrete Block --Int InsWhole House 6 6 0 9.33 0 56.0 ft2 0 0 0.8 0 19 W Exterior Concrete Block - Int InsWhole House 6 11.5 0 9.33 0 107.3_ft2 0 0 0.8 0 20 W Exterior Concrete Block - Int InsWhole House 6 . 6 0 9.33- 0 56.0 ft2 0 0 0.8 0 21 : W Exterior -Concrete Block -_Int InsWhole House 6 8 0 9.33: 0 74.6 ft2 0 0. : 6.8. 0 . 22 W Exterior Concrete Block - Int InsWhole House 6 9. 0 9.33 ' 0 84.0 ft2_ 0 0 0.8 0 23 N Garage Frame - Wood Whole House 13 17.5 0 9.33 0 163.3 ft2 0 0.23 . 0.8 0 _24 N Garage. -Frame,-.Wood Whole House 13 12.5 0 9.33 0 116.6ft2 0. 0,23. 0.8 0 DOORS # Ornt . .. Door Type Space.. Storms U-Value Width Height Area Ft In . Ft In T N. Insulated:- Whole House None :29 3 8 24 ft2 2 N Insulated Whole House None .29 3 8 24 ft2 3 N Insulated Whole House None'. .29 2.7. 8 21.4 ft2 W NDOWS Orientation shown is the entered; Proposed orientation. . / Wall IArea Overhang V # Ornt -ID Frame .. Panes .. NFRC : . U-Factor SHGC Imp . Depth Separation' Int Shade Screening 1 S 1' . Vinyl Low-E Double Yes 0.3 0.21 N 30.0 ft2 1 ft 0 in 1 ft 0 in. Drapes/blinds Exterior 5 2 E., 2 Vinyl Low=E Double Yes. 0.36 0.24 N 12.0 ft2 1 ft 0 in 1.ft 0 in None-.- None 3 N 4 Vinyl Low-E Double Yes 6.3 _ 0.21. N 20.0 ft2. 1 ft 0 in .1.ft 0 in None None 4 W 5 Vinyl. Low-E Double Yes 0.26 0.24 N 6.0 ft2 1 ft 0 in 1 ft,0 in None None 5 E 7 Vinyl Low-E Double Yes 0.3 0.21 N 4.0 ft2 1 ft0 in 1 ft 0 in None None 6 N 8 Vinyl Low-E Double Yes 0:3 0.21 N . 15.0 ft2 6 ft 0 in 1 ft 0 in . " None Exterior 5 7 N 10 - Vinyl Low-E Double Yes . 029 0:25 N 12.0 ft2 12 ft 0 in, 1 ft 0 in None .None 8 S 11 Vinyl : Low-E Double Yes 0.25 0.18 N 48.0 ft2 10 ft 0. in 1 ft 0 in None None 5/30I2018 4:18 PM EnergyGaugeO'USA Section R405.4.1 Compliant Software Page 3 of 5 FnRnA Rang-gn17 IAIPI IT RI IMMAR rHF('.KI IRT RFPt )RT WINDOWS Orientation shown is the entered, 'Proposed orientation. / Wall V • # Ornt ID 'Frame Panes NFRC Overhang lactor SHGC Imp Area Depth Separation Int Shade Screening 9 S 11 Vinyl 10 S 12 Vinyl 11 E . 13 Vinyl ' 12 E 15 Vinyl 13 W 16 Vinyl 14 W 19 Vinyl 15 W . 21 Vinyl 16 W 22 Vinyl Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low=E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes 0.3 0.21 N 30.0 ftz 10 ft 0 in 1 ft 0 in 0.3 0.21 N 30.0 ft2 1 ft 0 in . 1 ft 0 in 0.3 0.21 N 30.0 ft2 10 ft 0 in 1 ft 0 in 0.3 0.21 N 21.3 ft2 1 ft 0 in 1 ft 0 in 0.3 0.21 N 15.0 ft2 1 ft 0 in 1 ft 0 in 0.3 0.21 N 15.0 ft2 1 ft 0 in 1 ft 0 in 0.3 0.21 N 4.0 ft2 1 ft 0 in 1 'ft 0 in I0.3 0.21 N 4.0 ft2 2 ft 0 in 2 ft 0 in None . Drapes/blinds Drapes/blinds Drapes/blinds None None None None None Exterior 5 Exterior 5 None Exterior 5 Exterior 5 None None _ I GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 609 ft2 609 ft2 I 72 ft 9.33 ft 1 i INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000237 i 1753.6 96.27 181.05 .1799 4 i HEATING SYSTEM # System Type_ _ Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 31 kBtu/hr 1 sys#1 COOLING SYSTEM I # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ None I SEER: 16 34.8 kBtu/hr 1044 cfm 0.77 1 sys#1 i HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92I 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM . FSEC Cert # Company Name I Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 i r i 'I . a i i I i I i 5/30/2018 4:18 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 4 of 5 I Fr)RAA RAnr,_7n17 i INPUT SUMMAR, .CHECKLIST REPORT DUCTS." / ---- Supply ---- ---- Return �� Air .CFM 25 CFM25 HVAC # V # Location . R-Value Area Location A�ea Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Whole House 6 563.84 i Whole House 1.40.96 Default Leakage Whole Hou (Default). (Default) 1 1 TEMPERATURES i Programable Thermostat: Y . Ceiling Fans: Cooling r Jan r l Feb ]Mar Apr Mal X Jun Jul X Aug Sep Oct Nov Dec Heating XJan X] Feb Mar Apr May Jun �XjJul Aug Sep rj Oct Nov Dec Venting Jan jjj Feb lX] [X]]]]Mar Jun Jul Aug Sep lxl Thermostat Schedule: HERS 2006 Reference I Hours Schedule Type 1. 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 i 78 718 78 78 78 78 80 80 80 80 PM 80 80 78; 78 I. 78 78 78 78 78 78 78 .78 Cooling (WEH) AM 78 78 78 78 78 78 78. 78 78 78. 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 6I6 66 68 68 68 68 68 68 68 PM 68 68 68 6 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM. 68 68 - 68 68 68 68 68 68 68_ 68 66 66 i MECHANICAL VENTILATION i Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time. Cooling System Runtime Vent 85. 0 I 0 1 - Electric Strip Heat % 1 -.Central Unit 1 MASS Mass Type LDefault(8 Area I Thickness Furniture Fraction Space Ibs/s .ft. 0 ft2 . I 0 ft 0.3 Whole House Name: Ken Fonorow Rating Compant: Ken Fonorow Date: S �Jl 1 L'JL i I i i 5/30/2018 4:18 PM EnergyGaugeO USA Section R405.4.1 Compliant -Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL. (EPL) DISPLAY CARD I ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower. the Energy Performance Index, the more efficient the home.. 1.. New home or, addition 1. New (From Plans) 12. Ducts, location &insulation level a) Supply ducts R 6.0 2. Single -family -or multiple -family 2. Single-family b) :Return ducts R 6.0 c) AHU location -Whole, House/Whole House 3. No. of units (if,multiple-family) 3. 1 4. Number of bedrooms' { .4. 4 13., Cooling system: Capacity 34.8 a) Split system SEER 5: Is this.a worst case? (yes/no) 5. No b) Single. package SEER c) Ground/water source SEER/COP 6.'Conditioned floor area (sq. ft.) 6. .2819 d) Room unit/PTAC EER e) Other .. 16.0 7.. Windows, type and area a) U-facion(weighted average) 7a. 01293 b) Solar Heat Gain Coefficient (SHGC) 7b. 01209. 14.. Heating system: Capacity 31.0 c) Area 7c. 296.3 a) Split system heat pump HSPF b) .Single package heat pump HSPF 8:.8kylighfs:. c) Electric resistance COP. 1.0 - a)- U-factor:(weighted•average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient .(SHGC) 8b. I NA e) Gas .furnace,LPG AFUE f) Other. 9. Floor type, insulation level: . a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised' (R-value) 9b. 1 15. Water heating system c) Concrete, raised (R-value) 9c. 1 a) Electric resistance : EF 0.92 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF . A. Exterior: d), Solar system with tank EF 1. Wood frame (Insulation 'R-value) 10A1. e) Dedicated heat pump with tank EF 2- Masonry (Insulation R-value). _ 10A2. 16.0 f) Heat recovery unit :. HeatRec% B. Adjacent: 9) Other 1 Wood frame (Insulation R-value) 10131. 13.0 2. Masonry (Insulation R-value) 10132. . 16. HVAC credits claimed (Performance Method) 11. Ceiling type andinsulation: level Lo a) .Ceiling fans a) Under attic 11a. b) Cross ventilation No . b) Single assembly 11b. c) Whole house fan No c) Kneewalls/skylight walls, 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. INo e) Multizone heating:credit f) Programmable thermostat Yes "`Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1. certify that this home has complied -with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise,; a new. EPL display card will be completed based on installed code compliant features. Bwlder Address of New Home: Date: nLQL City/FL Zip:. Fort Pierce, FL 33945 5/30/2018 4:19:13 PM EnergyGauge® USA 6.0.02-,FlaRes2017 FBC 6th Edition (2017) Compliant Software. Page 1. of 1 1