HomeMy WebLinkAboutOPTIONAL LOADS CALCULATIONSOptional Load Calculati
Heat Larger Than Air
BY
St Lucie County
Ci L > SF x 3VA'Llving Only
(2) Small appliance ckts @ 1500VA each
Refrigerator @ 1500
Refrigerator @ 1500 R:County,
ED
Freezer @ 1500
Washing Machine @ 1500 A20V
Dishwasher @ 1500
Disposal @ 1500 ST. LucPei
Mini Sewer @ 1500
Clothes Dryer @ 5000
Range @ 12000
Water heater @ 4500
Fixed microwave @ 1500
Vacuum @ 15.00
Trash Compactor @ 1500
Pool Heater @ `name plate'
Spa @ 'name plate'
Motors 746VA per HP
Garage Door Opener
1) Total
2) First 10 KVA of general load @ 100%
3) Subtract line 2 from 1
4) Multiply line 3 @ 40%
5) Add lines 2 and 4
6) 60/50amp breaker for heat (10000)
7) • 40/30amp breaker for heat (5000)
s) Total heat -Add lines 6 and 7
9) Multiply line S @ 65%
10) Add lines 5 and 9
11) Divide line 10 by 240
Summary:
s the total KW
[L=1nell the total Amps
�( C� C) q
3000
ST.LUCIE COUNTY
PLAN REVIEW
BLDG:
LECX ELECf� 1 6
DATE:
PLUMB:
DATE:
MECH:
DATE:
(Generator Size Needed)
(Breaker Size Needed)
u� l
. -r
c
---fib
f
c
v