Loading...
HomeMy WebLinkAboutPROJECT INFORMATIONi a . J � _. 4 MINI� � iwmlr.Vrn P C �sIreas!1c-1 Lzn€,Inee r.ran SCANNED Ian l'ypes: BY r-lScree Room/Sun Room/Fill In St Lucie County ❑Pool Screed/Cage (Non-Removable'Screen — Designed to withstand actual Wind Speed) ❑Car Port Patio Cover ❑other: i *U Standard ❑Non Standard 011evision UCommercial ❑ $75.00 Rush Fee Project Address: 4018 GREENWOOD DR *City: FT PIERCE Date:.08 MAY 18 *Contractor Name: EDEN SCREEN & CONSTRUCTION CO., INC. *Address:1997 SE ESERBROOK ST `City: PORT ST LUCIE j `Zip Code: 34983 ! *Phone/Fax: 772-216-6171 Email: EDEN68@AOL.COM *Choose One:® trail ❑ Pick !gyp ❑E-File ❑Fed Ex* 3 No of Copies �X..For FedEx option go to wwNv alumiilunisereendesign.com and provide Fed.Ex account ) * ,Payment:, OCheck M Credit Card *(For Credit Card option go to.,\yw A, altunzinuznscreendesi�n.conl to pay by credit card) Engineering prepared by: j i A r Engineer: Michael Thompson; MSc, P.E. (P.E. # 47609) 4401 Vineland Road- Suite A6 Orlando, FL 32811 Ofiice:407-734-1470 Cell: 407-721-2292 Project Manager Paul Thomas 386479=9504 Fax 888-923-8181 Email; aiuniinums_reendeeiagITIL4lsoo.win Website: www.alut-ninumscreendesign.com CA#30930 ST. LLTC£E cJUlYT7r BUILD , ?-T' i REVIEWED FOR C'ViPL �T REVIEWED BY DATE 572t a ]PLANS AND PERMIT MUST E KEPT OR NO INSPECTION WI% E AM=. THESE PLANS AND ALL PROPOSED WORK ARE SUOJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH A.I. AAPLICADIJ CODED. 4 I CONCFALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTPIACTOR OF RECORD JOB 1 i I x„y;d ,,SS.N r xY' i (F V n 6, 4. Q t S S.{ 11t�mai p we '�S' neem� ct sed astectory O Risk Cy eat =nsujiate R Fascia F 1Block Ol�iiall rj�nve�etlonal Wall ❑ 4� wall prights 3"t2" X3°15„ Top Pate 2" X$" . Kick Plate n Dome nGalble nMansard 0$h,edtSIope F] Gutter nFConventional Wall Beams X Uprights X n X Kick Plate I far Post: ❑FInsulated ❑Pan Roof Gutter ❑Fascia ❑dock wall ❑iconventional Wall ❑ e Mall Beams X Post, 1 X. Patio Gwen F Insulated ❑Pan Roof Gutter [Fascia ❑dock Wall ❑Conventional Wall [] 4th Wall Beams X Post X Concrete• ® Existing ❑ New: 47'Siab nPier ❑Ribbon Footer X Pavers [16" Thickened Edge Other: 44".EXISITING NOM SLAB. 3"X3"X.093 POST IN THE FIELD AND 2"X5" SMB IN SCREEN WALUCARRIER BEAM. Note: In the event that there is a.confiict with the design plans and general notes and design. standard, the contractor shall utilize the more stringent dimensions and. member sizes prior to ordering materials, fabrication and/or construdon.between the plans and the general notes, and design standard. Engineer: Michael Thompson; MSc, P.E. (PE#47509) 4401 Vineland Road Suite A6, Orlando, FL 32811 h. f � . i IN SCREEN DESIGN _EI - mm A S DA'uminurn I i,onsirvcti.cn Enginee.0ing `r General Notes & Design Standards ✓ . (Screen Patio Room Enclosure) The following are general design standards. More stringent design standards may be noted on the plans. In the event of a conflict in plans and/or design standard dimensions and/or member sizes, the contractor must utilizerthe more, stringent dimensions and/or member sizes prior to ordering materials, fabrication and/or construction. Design Codes: Florida Building Code 2017 (61 Edition) Aluminum Design Manual 2015 ASCE 7-10 Design Loads: Pursuant to FBC Chapters 16 & 20 Ultimate Wind: -150 MPH (FBC Table 2002.4) (45 ps, fl Risk Category: -See attach site specific plan sheet (FBC Table 1604.5) Exposure Category: -See attach site specific plan sheet (FBC 1609.4.3) Additional Load requirements: Structural members supporting screened enclosures are designed for wind in both of two orthogonal directions using the pressures given in Table 2002.4. Each primary member is also designed for a 300 pound load applied vertically downward along any 1 foot of any member, not occurring simultaneously with wind load. In addition to wind pressures, purlins is also be designed for a 200 pound load applied vertically downward along any 1 foot of any member, not occurring simultaneously with wind load. Design Basis: Allowable Stress Design (ASD) =Allowable Strength Design (ASD) divide by safety factor General Requirements: Reproductions of contract drawings by contractor in lieu of preparation of shop drawings signifies acceptance of information shown as correct and obligates himself to any expense, real or implied, arising from their use. A change to the structural drawings due to the acceptance of alternates and/or substitutes is the responsibility of the contractor and must be submitted to the engineer for approval. The general contractor and each subcontractor shall review the approve construction plans in its entirety and verify all existing conditions prior to the start of any work. All inconsistencies shall be reported to the designer and/or structural engineer, if needed. Should contractor construct the premises in a fashion not consistent with the plans prepared by the designer and/or structural engineer, or in any fashion, change the plans and drawing without the review and approval from the designer and/or structural engineer. Then designer and/or structural engineer shall bear no responsibility or liability for the construction of premises and accuracy of the drawings. Foundation and Earthwork: Applicable only when unsuitable soils are encountered. When unsuitable soils are encountered as specified bearing strata, notify owner's representative/engineer. Soil bearing capacity — 2,000 psf Minimum Provide neat excavation for footing and place concrete immediately after excavation and inspection. Pump water from footing excavation if greater than one inch. Compact all fill to 95% ASTM D698 density. Unit soil weight = 105 pcf Internal angle of friction = 30 degrees Coeff. Of friction between footing and soil = 0.5 Michael Thompson, P.E. #47509/CA#30930 4401 Vineland Road., Suite A6, Orlando, FL 32811. (P) 407-734-1470 (F) 407-734-1790 www.aluminumscreendesign.com "1 1 DESIGN e) Dlurn)nurn w. C:;rsiruciinn E'n:gineer?ng � ((� Structural Aluminum: Conform to latest edition of Florida Building Code and Aluminum Design Manual standard practice for -,aluminum design. _ All aluminum shall be 6005-T5 (E= 10,000 ksi; Fy = 35 ksi) with a minimum wall thickness of 0.046" Splicing prohibited without prior approval as to location and type. Burning of holes in aluminum members is prohibited. Any member with burned holes must be replaced. Aluminum Protection: Shall be pursuant FBC 2003.8.4. Aluminum surfaces in contact with dissimilar materials, lime -mortar, concrete, or other masonry materials, shall be protected with powder coated or ESP paint or alkali -resistant coatings, such as heavy -bodied bituminous paint or water -white methacrylate lacquer. Screws: Aluminum self -tapping screws shall conform to ASME B18.6.4 specification. Self —tapping screws shall meet the requirements of ADM J.5 Maximum fastener spacing shall not exceed (3+20t) where "t" is the member thickness in inches. For roofing and siding connection, use minimum #12 screws for end and side laps spaced at 12" max for side lap and end lap fasteners shall be no more than 2" from the end of overlapping sheets. For bottom plate and column base, secure with ''/4" tapcons a minimum embedment of 1 1/8" and 2 '/4" respectively into concrete footer. Bolts: Bolts and other fasteners shall be aluminum, stainless steel, hot -dip or electro-galvanized steel. Double cadmium plated steel bolts may also be used. Bolt holes diameter shall not exceed 1/16" larger than the bolt diameter and shall be spaced at a minimum of 2.5 times the bolt diameter, with minimum edge distance of 1.5 times the bolt diameter. Bolts shall meet the requirements of ADM J.3 Chair Rails, Purlins & Wind Brace: Chair rails, purlins and wind brace shall conform with the below maximum span length. If the event contractor's specific site plan conflict with the below recommended length, the contractor shall utilize the more stringent dimensions and member sizes prior to ordering materials,. fabrication and/or construction. Wind Speed =150 MPH 2 x 2 Chair Rail = 4'-9" 2 x 2 Purlins = 6'-6" 2 x 2 Wind Brace = 4'-3" 2 x 3 (0.125) Wind Brace = 8'-0" 2 x 3 Chair Rail = 6'-9" 2 x 3 Purlins = 6'-9" 2 x 3 Wind Brace = 6'-9" 2 x 4 Wind Brace = 8'-0" Concrete Conform to ACI 318, latest edition and ACI 301 Compressive Ultimate Strength (Minimum at 28 days) shall be 3000 psi Exposed chamfer edges shall be 3/4" Reinforcing Steel: Conform to ACI 318 and 315, Latest edition All reinforcement steel shall be ASTM A615 Grade 60. Smooth dowels & ties shall be ASTM A185 Welded Wire Fabric shall be ASTM A185 or A82 (Flat sheet). Deformed bar anchors shall be ASTM A496, Grade 70 Cover: Footing 3" Washer: Washers shall be used under bolt heads and under nuts. Michael Thompson, P.E. #47509/CA#30930 4401 Vineland Road., Suite A6, Orlando, FL 32811. (P) 407-734-1470 (F) 407-734-1790 www.aluminumscreendesign.com E AALUMINUIAI SCREEN DESIGN DA!urrOnum & G-artsirvetinn E.n;ginee.ring Hole Alignment: - Poor matching holes must be rejected. Contractor shall prevent holes from drifting and distort the metal,.All chips and foreign matter between contacting surfaces shall be removed before assembly. , - Beams & Uprights: In the event of a conflict with the values in this table and the site specific plan, the contractor must utilize the more stringent dimensions and/or member sizes between the site specific plan and the below applicable span limitations z prior to ordering materials, fabrication and/or construction. 150 MPH PRIMARY BEAMS & COLUMNS -SCREEN & PATIO ROOM ENCLOSURES ROOF PANELS Max Beam Span & Max Column Insulated Roof Beam -Size Spacing Column -Size Max Column -Height Pan Roof Span Span 3" Spans 11'- 2 X 3 61-01 1 2 X 3 7'-0" 5" 3" Spans 12'-9" 6" Spans 16'-11" 2 X 4 8'-0" 2 X 4 7'-0" 2 X 5 9'-6" 2 X,5 8'-0" Knee Bracing: Contractor shall provide knee bracing on 45 degree angle pursuant the attach detail sheet that specified size and length requirements. Knee bracing on upright above super gutter intersection shall be connected to upright no more than 6" above the super gutter. Knee brace size shall be a minimum of 2 x 2 for beam span of 15' max; 2 x 3 for 30' max; 2 x 4 for beam span greater'than 30'. Purlin• Contractor is required to install purlins spaced to align with column spacing; however, spacing between purlins shall not exceed 7'-2". Intermediate/Header Beam: Contractor is required to install a minimum 2 x 7 intermediate header beam supported with 3 x 3 column spaced at 10 feet (max) when insulated roof span exceeds 15 feet. Patio Cover: Contractor is required to install insulated roof covering pursuant to the Florida product approval specification. Overhang shall be a maximum of l'-0" along the side, 3'-0" along the front and 1/2" along the front interface between the super gutter and the attached pool cage knee riser wall. Maximum deflection shall be limited to L/80. Edge Distance: Contractor is required to install uprights to provide a 2" minimum clearance from edge of slab and/or footer. Vinyl, tempered glass, and acrylic panels: Vinyl, tempered glass, and acrylic panels shall be removable. Removable panels shall be identified as removable by a decal. The identification decal shall essentially state "Removable panel SHALL be removed when wind speeds exceed 75 mph (34 m/s)." visible when the panel is installed. Michael Thompson, P.E. #47509/CA#30930 4401 Vineland Road., Suite A6, Orlando, FL 32811. (P) 407-734-1470 (F) 407-734-1790 www.aluminumscreendesign.com EDEN SCREEN 772-216-6171 EDEM68 �Aib OL.CQE�Jf JOS: KEPFER, 4018 GREEN�/OOD DR, FT PIERCE, FL 94982 140MPH EXP C 99 ': M- in the event Of a aontiiht in member sizes sie ahown on must the plop and the flenerel nOW51 i ent member size requirements. utilize the more ..� sod vvC w� ` :A �M11 KTRUDED FASCIA IS ATTACHED TO 'INSULATED ROOF WITH #10.1" 6" ZOM ENDS 24" O.C. 3X3 POSTS ARE ATTACHED TO 2X8 BEAM 2 3/8" X 3 1/2" CARRIAGE BOLTS TYP. 1X2 IS ATTACHED TO 3X3 POST WITH #10 2" 6" FROM ENDS 24" O.C. ROOF IS ATTACHED TO GUTTER GUTTER IS ATTACHED TO FASCIA WITH (4) #10 4" PER PANEL �' #10 2" 6" FROM ENDS 24" O.0 3" INSULATED ROOF IS ATTACHED TO ALUMINUM STRUCTURE WITH 910 4" 6" FROM ENDS 24" O.C. UPRIGHTS ARE ATTACHED WITH: 2X2 TOP PLATE BLIND SCREWED WITH (3) #10 3", CAPRI CLIPPED WITH (4) #10 1 PER BLIND CLIPPED WITH (4) #10 1" PER CHAIR RAIL IS ATTACHED TO UPRIGHTS WITH EITHER: BLIND SCREWED WITH (3) #10 3" OR, CAPRI CLIPPED WITH (4) #10 1" PER CLIP OR BLIND CLIPPED WITH (4) #10 1" PER CLIP UPRIGHTS ARE ATTACHED WITH: BLIND SCREWED WITH (3) #10 2" OR, CAPRI CLIPPED WITH (4) #10 1" PER CLIP & BLIND CLIPPED WITH (4) #10 1" PER CLIP IX2 IS ATTACHED TO BLOCK STRUCTURE WITH 2-1/4"-X 1/4" TAPCONS 6" FROM ENDS 24" O.C. 2X3 CHAIR RAIL 1X2 IS ATTACHED TO CONCRETE WITH 2-1/4" X 1/4" TAPCONS (5" X 1/4" IF THRU PAVERS) 6" FROM ENDS 24" O.C. DESIGN STATEMENT MICHAEI THOl�'Il'SON 1.046 THICKNESS OR GREATER, ALLOY IS 6005-T5 4401 VINELAND ROAD PROVIDE M 41MUM OF 1 1/8" CONCRETE EMBEDMENT DEPTH �, _ S'(TITE l�6 D IN H EDITION) u O EN SOTRUCTURES D SHALL WANCE TO MEET THE ITH STDT�OI T4AHEEE 017 WIND SPEEDS OF 150 MPH ORLANDO, .rL 32811 PH UP TO A 15FT ROOF HEIGHT, FACTOR OF 1.0, AND EXPOSURE C, RISK CATEGORY 1. 947509 IS DIMENSIONS PRIOR TO MATERIAL PURCHASE, FABRICATION D CONSTRUCTION ?R IMMEDIATELY SHOULD SITE CONDITIONS DIFFER FROM CONSTRUCTION PLANS,A#3 093 0 0