t St Lucie COt lilt MIAMI-DADE COUNTY
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES ( R PRODUCT CONTROL SECTION
BOARD AND CODE ADMINISTRATION DIVISION ) 11805 SW 26 Street, Room208
Miami, Florida 33175-2474474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) wwv.miamidade.eov/economy
Extreme Metal Fabricators, LLC
2160 Poma Drive RECEIVED
Palm City, FL 34990
SCOPE: APR 8 0 018
This NOA is being issued under the applic r410 LTffF, 44lg ruing the use of construction materials. The
documentation submitted has been reviewe - ode County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by ludiaid Dadc, County Product Control Scci on that tiiS piouua. or matte ial iaiis to mect the rcquaciai3nts
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: DMC 5-V 26GA Steel Panel over Plywood deck
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
sh;j.h he available for inspection at the ioh site at the rennest of the Ruildinv Official. /)/
This NOA consists of pages 1 through S.
The submitted documentation was reviewed by Gaspar J Rodriguez.
MM
a
DADE COUNTY
...•
ST..LUCIE C00NTY
BUILbING DIVISION
REVOC_U11ED
FOR COMPLOL1Mnig
EWED BY_ y'
PLANS AND PERMIT
MUST BE KEP�`� q
INSPECT4QN.WTLC7
,Yntxatuui
Approval Date: 09/17/15
Page 1 of 5
ROOFING SYSTEM APPROVAL:
Cateaorv•
Sub -Category:
Material:
Deck Tvoe:
Maximum Desilin Pressure
Roofing
Metal, Panels (Non -Structural)
Steel
Wood
-121.75 PSF
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Product Dimensions Snecifications Descrintion
DMC 5-V 26GA Steel Length: 120" TAS 110 Corrosion resistant, galvanized steel or galvalume
Panel Height: 1/2" metal panel.
Width: 26"
(24" coverage)
Thickness 26GA
EVIDENCE SUBMITTED:
Test Anencv
Test Identifier
Test Name/Report
Date
Akzo Nobel Coatings, Inc.
Lab Form
ASTM G 153
71TTT A....1_1, T__7_.__i_.�T.._
A 1\t 3'10�/tit[l t. 2wuuvtvSlw, utc,.
AT77t- AA All Al
rylvlu'IJ�IYI-r Y--cyi,—lyY
AC1T11 .f T1 11r/
r1v x IVA Yi Yx T
1A/AO/A,1
1v/Vaw vs,
AKZC-001-02-02
AKZC-001-02-03
AKZC-001-02-04
AKZC-001-02-05
ArcnYtecrurai Testing
5&64i.62422-44
TAS W0
09i2.2i65
Architectural Testing
58461.01-122-44
TAS 125
09/23/05
Hurricane Test Laboratory, Inc.
0287-0512-07
TAS 125
07/23/07
PRI Asphalt Technologies, Inc.
, DMC-0030-02-01
TAS 100
04/02/08
MIAMFDADE COUNTY
NOA No.: 15-0309.10
• � • • , Expiration Date: 09/17/20
Approval Date: 09/17/15
Page 2 of 5
APPROVED ASSEMBLIES:
System:
DMC 5-V, 26GA Steel Panel
Deck Type:
Wood, Non -insulated
Deck Description:
New Construction ' 9/32" or greater plywood or wood plank.
mope Range:
L= ; iz or greater
Maximum Uplift
See Table A below
Pressure:
Deck Attachment:
In accordance with applicable Building Code, but in no case shall it be less than 8d annular
ring shank nails spaced 6" OC. In reroofing, where the deck is less than'9/32" thick
(Minimum "/32") the above attachment method must be in addition to existing attachment.
Underlayment:
Minimum underlayment shall be an ASTM D 226 Type H installed with a minimum 4"
side -lap and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps
and 12 gauge 1 '/4" annular ring -shank nails, spaced 6" OC at all laps and two staggered
rows 12" OC in the field of the roll or any approved underlayment having a current NOA.
Fire Barrier Board:
Any approved fire barrier having a current NOA. Refer to a current fire directory listing for
fire ratings of this roofing system assembly as well as the location of the fire barrier within
the assembly. See Limitation # 1.
Valleys:
Valley construction shall be in compliance with Roofing Application Standard RAS 133
and with the current published installation instructions and details in DMC Association of
Regional Manufacturers Installation Manual.
Metal Panels and
Install the "DMC 5-V 26GA Steel Metal Panels" including flashing penetrations, valleys,
Accessories:
end laps and accessories in compliance "DMC Association of Regional Manufacturers"
current, published installation instructions and in compliance with the minimum
requirements detailed in Roofing Application Standard RAS 133.
Panels shall be secured along the top of the V's with approved corrosion resistant #9 hex
head self drilling screws of sufficient length to penetrate through the sheathing a minimum
of 3/,6" with self sealing washers. See Detail A herein. The fasteners are to be placed at a
spacing listed in Table A below starting 3" from panel end.
TABLE A
MAXIMUM DESIGN PRESSURES
Roof Areas
Field
Perimeter and Corner'
Maximum Design Pressures
-60 PSF
-121.75 PSF
Maximum Clip Spacing
1 ri -4. ..1..47..E ..L_ll - L _
16" OC
S" OC
La ajrvaaLlUAI MAU HUL IJC a110WCQ
MIAMI•DADE COUNTY NOA No.: 15-0309.10
Expiration Date: 09/17/20
Approval Date: 09/17/15
Page 3 of 5
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters,
and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced
pressure zones (i.e. perimeters, extended corners and corners).
3. Panels may be rolls formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in
Roofing Application Standard RAS 133
4. All panels shall be permanently labeled with the manufacturer's name and/or Iogo, city and state, and the
following statement: "Miami -Dade County Product Control Approved" or with the Miami -Dade County Product
Control Seal as seen below. All clips shall be permanently labeled with the manufacturer's name and/or logo,
and/or model.
aMIAMI-DADE COUNTY
,...I
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
6. Panels may be jobsite roll formed with machine model #0290414; 3381213; 4260215. 5960197. 10811107 from
DMC Association of Regional Manufacturers.
MIAMI•DADE COUNTY NOA No.: 15-0309.10
Expiration Date: 09/17/20
Approval Date: 09/17/15
Page 4 of 5
Overlap
PROFILE DRAWINGS
DETAIL A
2;- WYCmOaC
Minimum 09 Hex Head
Overlap
END OF THIS ACCEPTANCE
1/T2"
I
1
C
-DADE COUNTY NOA No.: 15-0309.10
FTUBM
Expiration Date: 09/17/20
Approval Date: 09/17/15
Page 5 of 5