Loading...
HomeMy WebLinkAboutGENERATORLevel 1 option Features and benefits Robust product design and testing - The generator is designed to operate under extreme environmental conditions including cold weather starts at as low as -40' F. The generator is tested and certified per the latest EPA, UL and IBC Seismic standards and is capable of meeting NFPA 110 requirements when equipped with the necessary accessories and properly installed. Flexible exercise mode - The innovative, flexible exercise mode enables the generator to exercise at a time, frequency and duration that suits the customer's prIeference - as little as 2 minutes every 6 months - reducing unnecessary fuel consumption, emissions and noise. Advanced enclosure design - The aesthetically appealing enclosure incorporates special designs that deliver the quietest generator of its kind. Aluminum material plus durable powder coat paint provides the best anti- corrosion performance. The generator set enclosure has been evaluated to withstand 180 mph wind loads in accordance with ASIDE 7-10. The intelligent design has removable;panels and service doors to provide easy access for service and maintenance. Control system - The PowerCommand® electronic control is standard equipment and provides total generator set system integration including automatic remote starting/stopping, precise frequency and voltage regulation, alarm and status message display, output metering, auto -shutdown at fault detection and NFPA 110 level 1 compliance. Self -diagnostics and easy service - The PowerCommand@ electronic control provides industry- leading self - diagnostic capabilities. In addition, critical components of the generator are designed to ensure service and preventive maintenance can be completed in a short period of time. - I Weight, size, and sound level Weight: 1294 lbs. (587 kg) Size: Length 94 in (2388 mm), width 34 in (864 mm), height 45.5 in (11156 mm) Sound: 67 dB(A) at 23 ft (7 m) with sound level 1 enclosure Series Model Phase Voltage V Frequency Hz Rated amps' NG/LPV fuel Circuit breaker (Amps) RS36 C36 N6 1 120/240 60 150.0/150.0 175 3 120/208 60 124.9/124.9 150 3 120/240 60 108.3/108.3 125 3 277/480 60 54.1 /54.1 60 'Derating guidelines: Engine power available up to 1005m (3300 ft) at ambient temperatures up to 40° C (104° F). Above these elevations derate at 4% per 305m (1000 ft) and 2% per 10 ° C above 401 C (1041 F). 02021 Cummins Inc. I NAS-5777-EN (7/21) A052GO09 Product features Engine • Natural gas/propane 1800 rpm engine • Engine aircleaner— normal duty • Electronic governor, isochronous • Engine starter, 12 VDC motor i • Shutdown— low oil pressure • Extension — oil drain • Engine oil Fuel System • Single fuel — natural gas or propane vapor, fieldl selectable Alternator • 60 Hz, 1 phase, 4 lead, or 3 phase, 12 lead, • 120° C temperature rise at 40° C ambient • Exciter/Voltage regulator —torque match Control • PowerCommand® 1.1 I • Display language — English • Control mounting, right facing i Electrical • Single circuit breaker, UL certified, right -side mounted • Battery charging alternator, normal duty i • Battery charger — 6 Amp, regulated Cooling • Generator set cooling capability — 50 ° C • Shutdown — low coolant level • Engine coolant — 50/50 mixture • Extension — coolant drain Enclosure • Aluminum enclosure Sound Level 1 with muffler installed, sandstone color • Wind rating —180 mph Code compliance • UL 2200 • EPA emissions, emergency, stationary, 40CFR60 • IBC Seismic • NFPA 110 capable Generator set application • Coolant heater • Crank case vent heater i • Large battery rack • Flexible fuel line • Literature (English) — operator's manual, installation quick guide and manual, service manual Packaging • Shipping pallet, poly bag Generator set performance Governor regulation class: ISO 8528 Part 1 Class�62 Voltage regulation, no load to full load: ±1.0% Random voltage variation: ±1.0% Frequency regulation: Isochronous Random frequency variation: ± 0.75% @ 60 Hz Radio frequency emissions compliance: FCC code Title 47-part 15 Class B Engine Specifications Design: Turbocharged with aftercooler Bore: 86.5 mm (3.4 in) Stroke: 100.0 mm (3.94 in) Displacement: 2.4liters (143.5 in3) Cylinder block: Cast iron, in -line 4 cylinder Battery capacity: 550 Amps at ambient temperature of0°Fto32,F(-181Cto00C) Battery charging alternator: 50 Amps Starting voltage:12-Volt, negative ground Lube oil filter type(s): Spin -on with relief valve Standard cooling system: 50, C (122° F) ambient cooling system Rated speed: 1800 rpm Fuel supply pressure Minimum fuel supply pressure, kPa (in H20): 1.5 (6.0) Maximum fuel supply pressure, kPa (in H20): 3.5 (14.0) Warranty Base warranty — 2-year standby Extended warranties available ©2021 Cummins Inc. i NAS-5777-EN (7/21) A052GO09 Typical fuel consumption Fuel consumption — natural gas Fuel consumption — LP vapor Load: 1/4 112 .3/4 Full ft3/hr: 202.3 1292.3 382.3 472.3 1 m3/hr: 5.7 18.2 10.7 13.2 Conversion factor: 8.58ft3=11b 0.535m3 = 1 kg �+ 36.39 ft3 =1 gal Load: 1/4 1/2 3/4 Full ft3/h r: 79.8 114.1 148.4 182.7 m3/hr: 2.2 3.2 4.2 5.1 al/hr 2.2 3.2 4.1 5.1 Easy service and installation Display Removable. Service Door Oil Check Oil Fill 9 a � Ki k ©2021 Cummins Inc I NAS-5777-EN (7/21) A052G009 t 4: LATCHE FUELSERVCE .....S ARE $0 sERVJCE:PANEL:-^N :"" :CpNNECTIQN PANL KEY LOgKAB.M (3:2) RIGNTSIDE'VIEW/'' 11 " :LEFTSIDE:VIEW' SERVICEIPANEL SERVICEPANI Note: This outline drawing is provided for general reference only and is not intended for use in design or installation. For more information, see Operators and Installation manuals or contact your dealer for assistance. Automatic transfer panel configurations ..:.. ......... . ...... ....:1+.awn.............. . _.. ... .... .. ..... MAINLINE ....... .... METIER' McmR:::: . clncurc ...... ... _.... ...... ........DISTRIBUT10N:PA"J1L: btSTR�BUTION PANEL' TTMN 6 om: .. .. .:' TO LOADS: " ELIH " TO CQADS ' :iIGM1'LY11A,D7:.. nDWiDo�l t36NERATOH AUTOAGTIC TRANSi6R ➢Al1EL. •. GENERATOR AUTOM►TIC .. ' :TRANSfER�PANEL . Typical service entrance ATS model Typical non -service entrance ATS Installation (100/200A) , model installation (100/200A) 02021 Cummins Inc. I NAS-57774EN (7/21) A052GO09 :I,AWn Dedicated emergency standby service system (100/200A) 7 Accessories Transfer switch (sold separately) • HMI211 RS in -home display, including pre -configured • Automatic Transfer Switches available at various 12-inch harness , I amperages. (Refer to NAS-5810-EN, A-1568, S- • HMI211 remote display, including pre -configured 1639) 12-inch harness 0 Service Entrance models are also available, which • HM1220 remote display helps reduce the installation cost. • Auxiliary output relays (2) 0 All models listed to UL 1008 standard. • Auxiliary configurable signal inputs (8) and relay! • Available for both Indoor and Outdoor applications. outputs (8) 0 Compatibility with Cummins generator set helps • Annunciator — RS 485 reduce the installation time for the complete • Internet monitoring device — PowerCommand 500 application. • Battery chargers —stand-alone, 12V I Warranty policy • Enclosure Sound Level 1 to Sound Level 2 upgrade kit • Enclosure paint touch up kit i Cummins RS liquid cooled generator set models come with • Base barrier— elevated generator set a 2-year base warranty when used in EPA -Stationary • Alternator heater Emergency application. The RA series Automatic Transfer • Maintenance and service kit Switches come with a 2-year base warranty. Extended warranty options are available. Please contact your Cummins dealer for details. Standby rating based on: Applkable for supplying emergency power for the duration of normal power Interruption. No sustained overload capability Is available for this rating. IEquWalentto fuel stop power In ao oniance with 1f03046, AS2799, DIN6271 and B55514) nominally rated. See T030. Back feed to a utility system an cause electrocution and/or property damage. Do not connect to any building electdol except through an approved device or after building main breaker is open. 1 i Contact,your dealer for more information. Cummins Ina Box 3005 Columbus, IN 472024005 U.S.A. 1-B00-CUMMINS- (1-800-286-6467) cummins.com NAS-5777-EN (7/21) 02021 Cummins Inc. After sale support Largest dealer support network Cummins generator sets are supported by the best trained and certified dealer network in the industry. This network of knowledgeable dealers will help you select the right generator for your application and advise you on associated accessories for your generator. Cummins dealers can also help answer any questions you may have regarding operation and maintenances requirements of the generators. Certified dealers also offer a complete selection of commonly used generator set maintenance parts and manuals. Manuals: Operation and installation manuals ship with the generator set. To obtain additional copies or other manuals for this model, see your dealer. To easily locate the nearest certified dealer for Cummins generators in your area, or for more information, contact us at 1-800-344-0039 or visit power.cummins.com.