HomeMy WebLinkAboutENERGY EFFICIENCY CODEa SCANNED RECEI EV p
3
BY `�' APR 2 6 2018
FORM R405-2017 St Lucie County y
k rt
FLORIDA ENERGY EFFICI VCY:C D E�0-k B IN I
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: JOURNET RESIDENCE
Builder Name: ASSOCIATED HOMES, INC.
Street: 5105 PALMETTO DRIVE
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner:
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce I
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plani)
9. Wall Types (2054.6 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Polystyrene Bead AggrER=9.0 1828.20 ft2
b. Frame - Wood, Adjacent
R=11.0 226.33 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
10. Ceiling Types (2190.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 2190.00 ft2
6. Conditioned floor area above grade (ft2) 2190
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c.
R= ft
11. Duct s
R ft2
7. Windows (204.0 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: LAUNDRY
6 175
a. U-Factor: Sgl, U=0.54 92.I 0 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.55 60!00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25 I I
a. Central Unit
42.0 SEER:16.00
c. U-Factor: Sgl, U=0.55 34.00 ft2
SHGC: SHGC=0.22
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 1I .00 ft2
a. Electric Strip Heat
27.0 COP:1.00
SHGC: other (see details)
Area Weighted Average Overhang Depth: 000 ft.
Area Weighted Average SHGC: 0�246
14. Hot water systems
I
a. Electric
Cap: 40 gallons
8. Floor Types (2190.0 sqft.) Insulation ( Area
EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 21190.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
i
15. Credits
None
Glass/Floor Area: 0.093 Total Proposed Modified Loads: 63.08
PASS
ITotal Baseline
Loads: 70.73
SrATc�
1 hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this
QFTKE
ti ' _; p�
Code.
calculation indicates compliance
, ,_
�jiip '' _ _ �' `VO
PREPA D Y: 6�
with the Florida Energy Code.
Before is
16.
DATE. _
construction completed
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
COD WE T¢�
OWNER/A EN •
BUILDING OFFICIAL:
DATE: `6 ;
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
3/16/2018 11:20 AM Energ'yGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 6
I
101:1�1iI:ZS1F"WOVl
i PROJECT
Title:
JOURNET RESIDENCE
Bedrooms:
4
Address Type:
Street Address
Building Type:
User
Conditioned Area:
2190
Lot #
Owner Name:
Total Stories:
1
Block/Subdivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
ASSOCIATED HOMES, INC.
RotatelAngle:
0
Street:
5105 PALMETTO DRIV
Permit Office:
ST LUCIE COUNTY
CrossVentilation:
No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whold House Fan:
No
City, State, Zip:
FORT PIERCE,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
I CLIMATE
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNIi
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2190
19952
SPACES
I
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
MASTER BEDROO
221
2011.1 No
0
1
1
Yes
Yes
Yes
2
WIC 1
32
259.2 No
0
1
Yes
Yes
Yes
3
WIC 2
36
291 I6 No
0
1
Yes
Yes
Yes
4
MASTER BATH
174
I
140I .4 No
0
1
Yes
Yes
Yes
5
LIVING ROOM
151
1525.1 No
0
1
Yes
Yes
Yes
6
FOYER
104
1050.4 No
0
1
Yes
Yes
Yes
7
DINING ROOM
143
I
1444.3 No
0
1
Yes
Yes
Yes
8
FAMILY ROOM
320
3232 No
0
1
Yes
Yes
Yes
9
KITCHEN
190
19119 Yes
0
1
Yes
Yes
Yes
10
CAFE
88
888.8 No
0
1
Yes
Yes
Yes
11
BEDROOM 2
139
1125.9 No
i
0
1
1
Yes
Yes
Yes
12
CLST2
16
i
129.6 No
0
1
Yes
Yes
Yes
13
CLST.3
18
145.8 No
0
1
Yes
Yes
Yes
14
BEDROOM 3
136
1101.6 No
0
1
1
Yes
Yes
Yes
15
BATH
48
388.8 No
0
1
Yes
Yes
Yes
16
BEDROOM 4
128
1036.8 No
0
1
1
Yes
Yes
Yes
17
CLST 4
18
145.8 No
i
0
1
Yes
Yes
Yes
18
LAUNDRY
66
534.6 No
0
1
Yes
Yes
Yes
19
HALLWAY
64
518.4 No
0
1
Yes
Yes
Yes
20
M.TOILET
32
'259.2 No
0
1
Yes
Yes
Yes
21
BATH 3
66
:634.6 No
2
1
Yes
Yes
Yes
i
3/16/2018 11:20 AM EnergyGaugI e® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2017
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulation
MASTER BEDRO
39 ft
0
221 ft2
____
0
1
0
2 Slab -On -Grade Edge Insulation
WIC 1
8 ft
0
32 ft2
____
0
1
0
3 Slab -On -Grade Edge Insulation
WIC 2
11 ft
0
36 ft2
0
1
0
4 Slab -On -Grade Edge Insulation
MASTER BATH
22 ft
0
174 ft2
0
1
0
5 Slab -On -Grade Edge Insulation
LIVING ROOM
, 15 ft
0
151 ft2
0
1
0
6 Slab -On -Grade Edge Insulation
FOYER
8 ft
0
104 ft2
--_-
0
1
0
7 Slab -On -Grade Edge Insulation
DINING ROOM
11 ft
0
143 ft2
__--
0
1
0
8 Slab -On -Grade Edge Insulation
FAMILY ROOM
16 ft
0
320 ft2
0
1
0
9 Slab -On -Grade Edge Insulation
KITCHEN i
1 ft
0
190 ft2
0
1
0
10SIab-On-Grade Edge Insulation
CAFE
I
8 ft
0
88 ft2
____
0
1
0
11SIab-On-Grade Edge Insulation
BEDROOM 21
19.9 ft
0
139 ft2
____
0
1
0
12SIab-On-Grade Edge Insulation
I
CLST 2
1 ft
0
16 ft2
___
0
1
0
13SIab-On-Grade Edge Insulation
CLST 3 j
2 ft
0
18 ft2
____
0
1
0
14SIab-On-Grade Edge Insulation
BEDROOM 3
24 ft
0
136 ft2
__e
0
1
0
15SIab-On-Grade Edge Insulation
BATH
5 ft
0
48 ft2
____
0
1
0
16SIab-On-Grade Edge Insulation
BEDROOMI4
11 ft
0
128 ft2
0
1
0
17SIab-On-Grade Edge Insulation
CLST 4
1 ft
0
18 ft2
0
1
0
18SIab-On-Grade Edge Insulation
LAUNDRY
1 ft
0
66 ftZ
____
0
1
0
19SIab-On-Grade Edge Insulation
HALLWAY
1 ft
0
64 ft2
__e
0
1
0
20SIab-On-Grade Edge Insulation
I
M TOILET
I
12 ft
0
32 ft2
__e
0
1
0
,
21SIab-On-Grade Edge Insulation
BATHi3
6 ft
0
66 ft2
____
0
1
0
i
ROOF
/
Roof
Gable Roof
Solar
SA Emitt
Emitt
Deck
Pitch
V/ # Type Materials Area
Area Color
Absor.
Tested
Tested
Insul.
(deg)
I
1 Hip Composition shingles 2449 ft2
0 ft2 Medium
0.6
No 0.9
No
0
26.6
ATTIC
J#
Type
Ventilation
Vent Ratio (1 in)
Area
RBS IRCC
1 Full attic
Vented
150 2190 ft2
N N
3/16/2018 11:20 AM EnergyGauge@ USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 6
FORM R405-2017
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) MASTER BEDRO
30
Blown
221 ft2
0.1
Wood
2
Under Attic (Vented) WIC11
30
Blown
32ft2
0.1
Wood
3
Under Attic (Vented) WIC 2
30
Blown
36 ft2
0.1
Wood
4
Under Attic (Vented) MASTER BATH
30
Blown
174 ft2
0.1
Wood
5
Under Attic (Vented) LIVING ROOM
30
Blown
151 ft2
0.1
Wood
6
Under Attic (Vented) FOYER
30
Blown
104 ft2
0.1
Wood
7
Under Attic (Vented) DINING ROOM
30
Blown
143 ft2
0.1
Wood
8
Under Attic (Vented) FAMILY i OOM
30
Blown
320 ft2
0.1
Wood
9
Under Attic (Vented) KITCHEN
30
Blown
190 ft2
0.1
Wood
10
Under Attic (Vented) CAFE
30
Blown
88 ft2
0.1
Wood
11
Under Attic (Vented) BEDROOM 2
30
Blown
139 ft2
0.1
Wood
12
Under Attic (Vented) CLSI 2
30
Blown
16 ft2
0.1
Wood
13
Under Attic (Vented) CLST 3
30
Blown
18 ft2
0.1
Wood
14
Under Attic (Vented) BEDROOM 3
I
30
Blown
136 ft2
0.1
Wood
15
Under Attic (Vented) BATH
30
Blown
48 ft2
0.1
Wood
16
Under Attic (Vented) BEDRI OM 4
30
Blown
128 ft2
0.1
Wood
17
Under Attic (Vented) CLST 4
30
Blown
18 ft2
0.1
Wood
18
Under Attic (Vented) LAUINDRY
30
Blown
66 ft2
0.1
Wood
19
Under Attic (Vented) HALLWAY
30
Blown
64ft2
0.1
Wood
20
Under Attic (Vented) M IOILET
30
Blown
32 ft2
0.1
Wood
21
Under Attic (Vented) BATH 3
30
Blown
66 ft2
0.1
Wood
i
WALLS
Adjacent Space Cavity
Width
Height
Sheathing Framing Solar
Below
ft
QMt
In Wall Typei
1
N
Exterior Concrete Block - PolystyI TER BE
9
17
0 9
1
154.4 ft2
0
0
0.6
0
_ 2
W
Exterior Concrete Block - PolystydiTER BE
9
13
0 9
1
118.1 ft2
0
0
0.6
0
3
S
Exterior Concrete Block - Polys4q TER BE
9
9
0 9
1
81.8 ft2
0
0
0.6
0
4
N
Exterior Concrete Block - Polystyren�IC 1
9
8
0 8
1
64.7 ft2
0
0
0.6
0
5
N
Exterior Concrete Block - PolystyddikSTER BA
9
14
0 8
1
113.2 ft2
0
0
0.6
0
6
E
Exterior Concrete Block - 1-01y,9LY11 BA
9
8
0 8
1
64.7 ft2
0
0
0.6
0
7
N
Exterior Concrete Block - Polystyddk*NG ROO
9
3
0 10
1
30.3 ft2
0
0
0.6
0
8
E
Exterior Concrete Block - Polystyd WNG ROO
9
12
0 10
1
121.0 ft2
0
0
0.6
0
9
E
Exterior Concrete Block - Polystyren60YER
9
8
0 10
1
80.7 ft2
0
0
0.6
0
10
E
Exterior Concrete Block - PolystytNG ROO
9
11
0 10
1
110.9 ft2
0
0
0.6
0
11
W
Exterior Concrete Block - PolystyFMMILY ROO
9
16
0 10
1
161.3 ft2
0
0
0.6
0
12
W
Exterior Concrete Block - PolystyreneCAFE
9
8
0 10
1
80.7 ft2
0
0
0.6
0
13
N
Exterior Concrete Block - PolystyMIDROOM 2
9
9
0 8
1
72.8 ft2
0
0
0.6
0
14
W
Exterior Concrete Block - PolystyrmlDROOM 2
9
11
0 8
1
88.9 ft2
0
0
0.6
0
15
W
Exterior Concrete Block - Polyst�, enDLST 3
9
2
0 8
1
16.2 ft2
0
0
0.6
0
16
W
Exterior Concrete Block - Polysty&.EDROOM 3
9
11
0 8
1
88.9 ft2
0
0
0.6
0
17
S
Exterior Concrete Block - PolystyREDROOM 3
9
13
0 8
1
105.1 ft2
0
0
0.6
0
18
S
Exterior Concrete Block - PolystyrenEBATH
9
5
0 8
1
40.4 ft2
0
0
0.6
0
19
S
Exterior Concrete Block - PolystyMDROOM 4
9
11
0 8
1
88.9 ft2
0
0
0.6
0
3/16/201811:20 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 6
01V►TAIYS1490111VA
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
Space
20 N
Exterior
Concrete Block - PolystyrehbTOILET
9 4
0 8
1
32.3 ft2
0
0 0.6
0
21 E
Exterior
Concrete Block - PolystyrelabTOILET
9 8
0 8
1
64.7 ft2
0
0 0.6
0
22 S
Exterior
Concrete Block - Polystyren@ATH 31
9 6
0 8
1
48.5 ft2
0
0 0.6
0
_23 S
Garage
Frame -Wood
DINING ROO 11 7
8
1
56.6ft2
0
0 0.600000 0
24 E
Garage
Frame - Wood
LAUNDRY
I
11 21
8
1
169.8 ft2
0
0 0.600000 0
I
DOORS
#
Omt
Door Type
Space I
Storms
U-Value
Width
Area
Ft
In
FHeigh'n
1
W
Insulated
FOYER
None
.39
6
6 8
40ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
#
Omt ID
Frame Panes
NFRCJ
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
N
1
Metal Low-E Single
Yes1
0.45 0.26
N
12.0 ft2
1 ft 0 in
1 ft 4 in
None
None
2
W
2
Metal Low-E Single
Yes
0.54 0.25
N
20.0 ft2
1 ft 0 in
1 ft 4 in
None
None
3
N
5
Metal Low-E Single
Yes
0.54 0.25
N
12.0 ft2
1 ft 0 in
1 ft 4 in
None
None
4
E
8
Metal Low-E Single
Yes
0.55 0.22
N
15.0 ft2
1 ft 0 in
1 ft 4 in
None
None
5
E
10
Metal Low-E Single
Yes
0.55 0.22
N
15.0 ft2
1 ft 0 in
1 ft 4 in
None
None
6
W
11
Metal Low-E Single
Yes
0.55 0.25
N
60.0 ft2
1 ft 0 in
1 ft 4 in
None
None
7
W
12
Metal Low-E Single
Yes
0.54 0.25
N
15.0 ft2
1 ft 0 in
1 ft 4 in
None
None
8
W
14
Metal Low-E Single
Yes
0.54 0.25
N
15.0 ft2
1 ft 0 in
1 ft 4 in
None
None
l
9
W
16
Metal Low-E Single
Yes
0.54 0.25
N
15.0 ft2
1 ft 0 in
1 ft 4 in
None
None
10
S
18
Metal Low-E Single
Yes
0.45 0.26
N
6.0 ft2
1 ft 0 in
1 ft 4 in
None
None
11
S
19
Metal Low-E Single
Yes
0.54 0.25
N
15.0 ft2
1 ft 0 in
1 ft 4 in
None
None
12
E
21
Metal Low-E Single
Yes
0.55 0.22
N
4.0 ft2
1 ft 0 in
1 ft 4 in
None
None
I
GARAGE
#
Floor Area Ceiling Area'
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
441 ft2 441 ft2 I
28 ft
8 ft
11
INFILTRATION
# Scope
Method
I
SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse
Proposed ACH(50)
1
.000405 2327.7 127.79
240.33
.2958
7
3/16/2018 11:20 AM EnergyGai ge® USA- FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 6
I
FORM R405-2017
HEATING SYSTEM
#
System Type
Subtype
it Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/
None
j COP:1
27 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
i Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1
Central Unit/
Split
SEER: 16
42 kBtu/hr
1260 cfm
0.8
1
sys#1
HOT WATER SYSTEM
i
#
System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1
Electric
None
Garage
I 0.98 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
i
FSEC
Collector
Storage
Cert
# Company Name
System Model # Collector
Model # Area
Volume
FEF
None None
I
ft2
I
DUCTS
— Supply --
— Return —
Air
CFM 25
CFM25
HVAC #
V #
Location R-Value
Area
Locatio
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic
6 175 ft2
Attic I
17 ftz Default Leakage
LAUNDRY
(Default) c(Default) c
1 1
I
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
i
Cooling
Ht
Jan Feb
Jan Feb
H
Mar
Mar
Apr
I
May Jun Jul
Jun Ju
AugSep
Au
Se
Oct
Oct
Nov
Nov
Dec
Dec
Venting
Jan Feb
X Mar
Apr
May Jun Jul
Aug
Sep
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 I3
4 5 6
7
8
9
10
11
12
Cooling (W D)
AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 80
80 78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 80
80 78 78
78
78
78
78
78
78
Heating (W D)
AM
65
65 1 65
65 65 65
65
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
68
68
Heating (WEH)
AM
65
65 165
65 65 65
65
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
68
68
3/16/2018 11:20 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: JOURNET RESIDENCE Builder Name: ASSOCIATED HOMES, INC.
Street: 5105 PALMETTO DRIVE Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Owner: Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce ;
COMPONENT'
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not.be used as a sealing material.
requirements
Breaks or joints in the air barrier shall!be sealed.
Ceiling/attic
i
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls shall
The junction of the top plate and theltop of exterior walls shall be sealed.
be insulated by completely filling the cavity with a
Knee walls shall be sealed. i
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
j
alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
skylights and framing shall be sealed.
and doors
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed atlany exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
I
be permitted to be in contact with the top side of
l
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottom
i
I
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations •
Duct shafts, utility penetrations, land flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wirin .
Shower/tub
The air barrier installed at exl�erior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklets
in a manner that is recommended by the manufacturer. Caulking or other
r.
adhesive sealants shall not(be used to fill voids between fire sprinkler
cover Nates and walls or ceilin s.
a. in auumon, mspecnon of iog wars snaii be in accorpance with the provisions of IGG-4uu.
3/16/2018 11:20 AM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 89
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows"
Description
a. U-Factor:
Sgl, U=0.54
SHGC:
SHGC=0.25
b. U-Factor:
Sgl, U=0.55
SHGC:
SHGC=0.25
c. U-Factor:
Sgl, U=0.55
SHGC:
SHGC=0.22
d. U-Factor:
other (see details)
SHGC:
other (see details)
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
5105 PALM
New (From Plans)
Single-family
1
i
4
No
2190
i
Area
92.00 ft2
60.00 ft2
i
34.00 ft2
18.01 ft2
1.000 ft.
0.246
Insulation Arela
i
R=0.0 2190.00 ft2
R= i ft2
R= ft2
i
I
I certify that this home has complied with the FII
Construction through the above energy saving f
in this home before final inspection. Otherwise,
based on installed Code compliant features.
Builder Signature: ��le np-A- -. A A,
Address of New Home:
DRIVE, FORT PIERCE, FL,
9. Wall Types
Insulation
Area
a. Concrete Block - Polystyrene Bead AggrER=9.0
1828.20 ft2
b. Frame - Wood, Adjacent
R=11.0
226.33 ft2
c. N/A
R=
ft2
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
a. Under Attic (Vented)
R=30.0
2190.00 ft2
b. N/A
R=
ft2
c. N/A
R=
ft2
11. Ducts
R ft2
a. Sup: Attic, Ret: Attic, AH: LAUNDRY
6 175
12. Cooling systems
kBtu/hr
Efficiency
a. Central Unit
42.0 SEER:16.00
13. Heating systems
kBtu/hr
Efficiency
a. Electric Strip Heat
27.0
COP:1.00
14. Hot water systems
Cap: 40 gallons
a. Electric
EF: 0.98
b. Conservation features
None
15. Credits None
1a Energy Efficiency Code for Building
Lures which will be installed (or exceeded)
new EPL Display Card will be completed
Date: 4 hd t g
City/FL Zip: ft 1?tc,,ve 3`1y-%
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
""Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
3/16/201811:20 AM EnergyGaugeg),l USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1