Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEa SCANNED RECEI EV p 3 BY `�' APR 2 6 2018 FORM R405-2017 St Lucie County y k rt FLORIDA ENERGY EFFICI VCY:C D E�0-k B IN I Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: JOURNET RESIDENCE Builder Name: ASSOCIATED HOMES, INC. Street: 5105 PALMETTO DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce I County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plani) 9. Wall Types (2054.6 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Polystyrene Bead AggrER=9.0 1828.20 ft2 b. Frame - Wood, Adjacent R=11.0 226.33 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 10. Ceiling Types (2190.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 2190.00 ft2 6. Conditioned floor area above grade (ft2) 2190 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. R= ft 11. Duct s R ft2 7. Windows (204.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: LAUNDRY 6 175 a. U-Factor: Sgl, U=0.54 92.I 0 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.55 60!00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 I I a. Central Unit 42.0 SEER:16.00 c. U-Factor: Sgl, U=0.55 34.00 ft2 SHGC: SHGC=0.22 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 1I .00 ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: other (see details) Area Weighted Average Overhang Depth: 000 ft. Area Weighted Average SHGC: 0�246 14. Hot water systems I a. Electric Cap: 40 gallons 8. Floor Types (2190.0 sqft.) Insulation ( Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 21190.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 i 15. Credits None Glass/Floor Area: 0.093 Total Proposed Modified Loads: 63.08 PASS ITotal Baseline Loads: 70.73 SrATc� 1 hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this QFTKE ti ' _; p� Code. calculation indicates compliance , ,_ �jiip '' _ _ �' `VO PREPA D Y: 6� with the Florida Energy Code. Before is 16. DATE. _ construction completed this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. COD WE T¢� OWNER/A EN • BUILDING OFFICIAL: DATE: `6 ; DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 3/16/2018 11:20 AM Energ'yGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 6 I 101:1�1iI:ZS1F"WOVl i PROJECT Title: JOURNET RESIDENCE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2190 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: ASSOCIATED HOMES, INC. RotatelAngle: 0 Street: 5105 PALMETTO DRIV Permit Office: ST LUCIE COUNTY CrossVentilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whold House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: I CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNIi 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2190 19952 SPACES I Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 221 2011.1 No 0 1 1 Yes Yes Yes 2 WIC 1 32 259.2 No 0 1 Yes Yes Yes 3 WIC 2 36 291 I6 No 0 1 Yes Yes Yes 4 MASTER BATH 174 I 140I .4 No 0 1 Yes Yes Yes 5 LIVING ROOM 151 1525.1 No 0 1 Yes Yes Yes 6 FOYER 104 1050.4 No 0 1 Yes Yes Yes 7 DINING ROOM 143 I 1444.3 No 0 1 Yes Yes Yes 8 FAMILY ROOM 320 3232 No 0 1 Yes Yes Yes 9 KITCHEN 190 19119 Yes 0 1 Yes Yes Yes 10 CAFE 88 888.8 No 0 1 Yes Yes Yes 11 BEDROOM 2 139 1125.9 No i 0 1 1 Yes Yes Yes 12 CLST2 16 i 129.6 No 0 1 Yes Yes Yes 13 CLST.3 18 145.8 No 0 1 Yes Yes Yes 14 BEDROOM 3 136 1101.6 No 0 1 1 Yes Yes Yes 15 BATH 48 388.8 No 0 1 Yes Yes Yes 16 BEDROOM 4 128 1036.8 No 0 1 1 Yes Yes Yes 17 CLST 4 18 145.8 No i 0 1 Yes Yes Yes 18 LAUNDRY 66 534.6 No 0 1 Yes Yes Yes 19 HALLWAY 64 518.4 No 0 1 Yes Yes Yes 20 M.TOILET 32 '259.2 No 0 1 Yes Yes Yes 21 BATH 3 66 :634.6 No 2 1 Yes Yes Yes i 3/16/2018 11:20 AM EnergyGaugI e® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2017 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation MASTER BEDRO 39 ft 0 221 ft2 ____ 0 1 0 2 Slab -On -Grade Edge Insulation WIC 1 8 ft 0 32 ft2 ____ 0 1 0 3 Slab -On -Grade Edge Insulation WIC 2 11 ft 0 36 ft2 0 1 0 4 Slab -On -Grade Edge Insulation MASTER BATH 22 ft 0 174 ft2 0 1 0 5 Slab -On -Grade Edge Insulation LIVING ROOM , 15 ft 0 151 ft2 0 1 0 6 Slab -On -Grade Edge Insulation FOYER 8 ft 0 104 ft2 --_- 0 1 0 7 Slab -On -Grade Edge Insulation DINING ROOM 11 ft 0 143 ft2 __-- 0 1 0 8 Slab -On -Grade Edge Insulation FAMILY ROOM 16 ft 0 320 ft2 0 1 0 9 Slab -On -Grade Edge Insulation KITCHEN i 1 ft 0 190 ft2 0 1 0 10SIab-On-Grade Edge Insulation CAFE I 8 ft 0 88 ft2 ____ 0 1 0 11SIab-On-Grade Edge Insulation BEDROOM 21 19.9 ft 0 139 ft2 ____ 0 1 0 12SIab-On-Grade Edge Insulation I CLST 2 1 ft 0 16 ft2 ___ 0 1 0 13SIab-On-Grade Edge Insulation CLST 3 j 2 ft 0 18 ft2 ____ 0 1 0 14SIab-On-Grade Edge Insulation BEDROOM 3 24 ft 0 136 ft2 __e 0 1 0 15SIab-On-Grade Edge Insulation BATH 5 ft 0 48 ft2 ____ 0 1 0 16SIab-On-Grade Edge Insulation BEDROOMI4 11 ft 0 128 ft2 0 1 0 17SIab-On-Grade Edge Insulation CLST 4 1 ft 0 18 ft2 0 1 0 18SIab-On-Grade Edge Insulation LAUNDRY 1 ft 0 66 ftZ ____ 0 1 0 19SIab-On-Grade Edge Insulation HALLWAY 1 ft 0 64 ft2 __e 0 1 0 20SIab-On-Grade Edge Insulation I M TOILET I 12 ft 0 32 ft2 __e 0 1 0 , 21SIab-On-Grade Edge Insulation BATHi3 6 ft 0 66 ft2 ____ 0 1 0 i ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V/ # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) I 1 Hip Composition shingles 2449 ft2 0 ft2 Medium 0.6 No 0.9 No 0 26.6 ATTIC J# Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2190 ft2 N N 3/16/2018 11:20 AM EnergyGauge@ USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2017 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 221 ft2 0.1 Wood 2 Under Attic (Vented) WIC11 30 Blown 32ft2 0.1 Wood 3 Under Attic (Vented) WIC 2 30 Blown 36 ft2 0.1 Wood 4 Under Attic (Vented) MASTER BATH 30 Blown 174 ft2 0.1 Wood 5 Under Attic (Vented) LIVING ROOM 30 Blown 151 ft2 0.1 Wood 6 Under Attic (Vented) FOYER 30 Blown 104 ft2 0.1 Wood 7 Under Attic (Vented) DINING ROOM 30 Blown 143 ft2 0.1 Wood 8 Under Attic (Vented) FAMILY i OOM 30 Blown 320 ft2 0.1 Wood 9 Under Attic (Vented) KITCHEN 30 Blown 190 ft2 0.1 Wood 10 Under Attic (Vented) CAFE 30 Blown 88 ft2 0.1 Wood 11 Under Attic (Vented) BEDROOM 2 30 Blown 139 ft2 0.1 Wood 12 Under Attic (Vented) CLSI 2 30 Blown 16 ft2 0.1 Wood 13 Under Attic (Vented) CLST 3 30 Blown 18 ft2 0.1 Wood 14 Under Attic (Vented) BEDROOM 3 I 30 Blown 136 ft2 0.1 Wood 15 Under Attic (Vented) BATH 30 Blown 48 ft2 0.1 Wood 16 Under Attic (Vented) BEDRI OM 4 30 Blown 128 ft2 0.1 Wood 17 Under Attic (Vented) CLST 4 30 Blown 18 ft2 0.1 Wood 18 Under Attic (Vented) LAUINDRY 30 Blown 66 ft2 0.1 Wood 19 Under Attic (Vented) HALLWAY 30 Blown 64ft2 0.1 Wood 20 Under Attic (Vented) M IOILET 30 Blown 32 ft2 0.1 Wood 21 Under Attic (Vented) BATH 3 30 Blown 66 ft2 0.1 Wood i WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below ft QMt In Wall Typei 1 N Exterior Concrete Block - PolystyI TER BE 9 17 0 9 1 154.4 ft2 0 0 0.6 0 _ 2 W Exterior Concrete Block - PolystydiTER BE 9 13 0 9 1 118.1 ft2 0 0 0.6 0 3 S Exterior Concrete Block - Polys4q TER BE 9 9 0 9 1 81.8 ft2 0 0 0.6 0 4 N Exterior Concrete Block - Polystyren�IC 1 9 8 0 8 1 64.7 ft2 0 0 0.6 0 5 N Exterior Concrete Block - PolystyddikSTER BA 9 14 0 8 1 113.2 ft2 0 0 0.6 0 6 E Exterior Concrete Block - 1-01y,9LY11 BA 9 8 0 8 1 64.7 ft2 0 0 0.6 0 7 N Exterior Concrete Block - Polystyddk*NG ROO 9 3 0 10 1 30.3 ft2 0 0 0.6 0 8 E Exterior Concrete Block - Polystyd WNG ROO 9 12 0 10 1 121.0 ft2 0 0 0.6 0 9 E Exterior Concrete Block - Polystyren60YER 9 8 0 10 1 80.7 ft2 0 0 0.6 0 10 E Exterior Concrete Block - PolystytNG ROO 9 11 0 10 1 110.9 ft2 0 0 0.6 0 11 W Exterior Concrete Block - PolystyFMMILY ROO 9 16 0 10 1 161.3 ft2 0 0 0.6 0 12 W Exterior Concrete Block - PolystyreneCAFE 9 8 0 10 1 80.7 ft2 0 0 0.6 0 13 N Exterior Concrete Block - PolystyMIDROOM 2 9 9 0 8 1 72.8 ft2 0 0 0.6 0 14 W Exterior Concrete Block - PolystyrmlDROOM 2 9 11 0 8 1 88.9 ft2 0 0 0.6 0 15 W Exterior Concrete Block - Polyst�, enDLST 3 9 2 0 8 1 16.2 ft2 0 0 0.6 0 16 W Exterior Concrete Block - Polysty&.EDROOM 3 9 11 0 8 1 88.9 ft2 0 0 0.6 0 17 S Exterior Concrete Block - PolystyREDROOM 3 9 13 0 8 1 105.1 ft2 0 0 0.6 0 18 S Exterior Concrete Block - PolystyrenEBATH 9 5 0 8 1 40.4 ft2 0 0 0.6 0 19 S Exterior Concrete Block - PolystyMDROOM 4 9 11 0 8 1 88.9 ft2 0 0 0.6 0 3/16/201811:20 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 6 01V►TAIYS1490111VA WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 20 N Exterior Concrete Block - PolystyrehbTOILET 9 4 0 8 1 32.3 ft2 0 0 0.6 0 21 E Exterior Concrete Block - PolystyrelabTOILET 9 8 0 8 1 64.7 ft2 0 0 0.6 0 22 S Exterior Concrete Block - Polystyren@ATH 31 9 6 0 8 1 48.5 ft2 0 0 0.6 0 _23 S Garage Frame -Wood DINING ROO 11 7 8 1 56.6ft2 0 0 0.600000 0 24 E Garage Frame - Wood LAUNDRY I 11 21 8 1 169.8 ft2 0 0 0.600000 0 I DOORS # Omt Door Type Space I Storms U-Value Width Area Ft In FHeigh'n 1 W Insulated FOYER None .39 6 6 8 40ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Omt ID Frame Panes NFRCJ U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Single Yes1 0.45 0.26 N 12.0 ft2 1 ft 0 in 1 ft 4 in None None 2 W 2 Metal Low-E Single Yes 0.54 0.25 N 20.0 ft2 1 ft 0 in 1 ft 4 in None None 3 N 5 Metal Low-E Single Yes 0.54 0.25 N 12.0 ft2 1 ft 0 in 1 ft 4 in None None 4 E 8 Metal Low-E Single Yes 0.55 0.22 N 15.0 ft2 1 ft 0 in 1 ft 4 in None None 5 E 10 Metal Low-E Single Yes 0.55 0.22 N 15.0 ft2 1 ft 0 in 1 ft 4 in None None 6 W 11 Metal Low-E Single Yes 0.55 0.25 N 60.0 ft2 1 ft 0 in 1 ft 4 in None None 7 W 12 Metal Low-E Single Yes 0.54 0.25 N 15.0 ft2 1 ft 0 in 1 ft 4 in None None 8 W 14 Metal Low-E Single Yes 0.54 0.25 N 15.0 ft2 1 ft 0 in 1 ft 4 in None None l 9 W 16 Metal Low-E Single Yes 0.54 0.25 N 15.0 ft2 1 ft 0 in 1 ft 4 in None None 10 S 18 Metal Low-E Single Yes 0.45 0.26 N 6.0 ft2 1 ft 0 in 1 ft 4 in None None 11 S 19 Metal Low-E Single Yes 0.54 0.25 N 15.0 ft2 1 ft 0 in 1 ft 4 in None None 12 E 21 Metal Low-E Single Yes 0.55 0.22 N 4.0 ft2 1 ft 0 in 1 ft 4 in None None I GARAGE # Floor Area Ceiling Area' Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 441 ft2 441 ft2 I 28 ft 8 ft 11 INFILTRATION # Scope Method I SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) 1 .000405 2327.7 127.79 240.33 .2958 7 3/16/2018 11:20 AM EnergyGai ge® USA- FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 6 I FORM R405-2017 HEATING SYSTEM # System Type Subtype it Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None j COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype i Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 42 kBtu/hr 1260 cfm 0.8 1 sys#1 HOT WATER SYSTEM i # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage I 0.98 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM i FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None I ft2 I DUCTS — Supply -- — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Locatio Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 175 ft2 Attic I 17 ftz Default Leakage LAUNDRY (Default) c(Default) c 1 1 I TEMPERATURES Programable Thermostat: N Ceiling Fans: i Cooling Ht Jan Feb Jan Feb H Mar Mar Apr I May Jun Jul Jun Ju AugSep Au Se Oct Oct Nov Nov Dec Dec Venting Jan Feb X Mar Apr May Jun Jul Aug Sep Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 I3 4 5 6 7 8 9 10 11 12 Cooling (W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (W D) AM 65 65 1 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 165 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 3/16/2018 11:20 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: JOURNET RESIDENCE Builder Name: ASSOCIATED HOMES, INC. Street: 5105 PALMETTO DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce ; COMPONENT' AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not.be used as a sealing material. requirements Breaks or joints in the air barrier shall!be sealed. Ceiling/attic i The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls shall The junction of the top plate and theltop of exterior walls shall be sealed. be insulated by completely filling the cavity with a Knee walls shall be sealed. i material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous j alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and skylights and framing shall be sealed. and doors Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed atlany exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) I be permitted to be in contact with the top side of l sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom i I to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations • Duct shafts, utility penetrations, land flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wirin . Shower/tub The air barrier installed at exl�erior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklets in a manner that is recommended by the manufacturer. Caulking or other r. adhesive sealants shall not(be used to fill voids between fire sprinkler cover Nates and walls or ceilin s. a. in auumon, mspecnon of iog wars snaii be in accorpance with the provisions of IGG-4uu. 3/16/2018 11:20 AM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 89 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows" Description a. U-Factor: Sgl, U=0.54 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.55 SHGC: SHGC=0.25 c. U-Factor: Sgl, U=0.55 SHGC: SHGC=0.22 d. U-Factor: other (see details) SHGC: other (see details) Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 5105 PALM New (From Plans) Single-family 1 i 4 No 2190 i Area 92.00 ft2 60.00 ft2 i 34.00 ft2 18.01 ft2 1.000 ft. 0.246 Insulation Arela i R=0.0 2190.00 ft2 R= i ft2 R= ft2 i I I certify that this home has complied with the FII Construction through the above energy saving f in this home before final inspection. Otherwise, based on installed Code compliant features. Builder Signature: ��le np-A- -. A A, Address of New Home: DRIVE, FORT PIERCE, FL, 9. Wall Types Insulation Area a. Concrete Block - Polystyrene Bead AggrER=9.0 1828.20 ft2 b. Frame - Wood, Adjacent R=11.0 226.33 ft2 c. N/A R= ft2 d. N/A R= ft2 10. Ceiling Types Insulation Area a. Under Attic (Vented) R=30.0 2190.00 ft2 b. N/A R= ft2 c. N/A R= ft2 11. Ducts R ft2 a. Sup: Attic, Ret: Attic, AH: LAUNDRY 6 175 12. Cooling systems kBtu/hr Efficiency a. Central Unit 42.0 SEER:16.00 13. Heating systems kBtu/hr Efficiency a. Electric Strip Heat 27.0 COP:1.00 14. Hot water systems Cap: 40 gallons a. Electric EF: 0.98 b. Conservation features None 15. Credits None 1a Energy Efficiency Code for Building Lures which will be installed (or exceeded) new EPL Display Card will be completed Date: 4 hd t g City/FL Zip: ft 1?tc,,ve 3`1y-% *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. ""Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/16/201811:20 AM EnergyGaugeg),l USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1