Loading...
HomeMy WebLinkAboutENGINEERING 7-13-18Y I E2UNIVE SAL Date Typedt No.: May 04, 20181.0009 ENGINEERING SCIENCES Consultants In: Geotechnical Engineeri g • Environmental Sciences Geophysical Services • Materials Tes mg • Threshold Inspection Building Code Administration, Compli nce Inspection & Plan Review 820 Brevard Avenue, Rockledge, FL 32965 - P: 321.638.0808 - F: 321.638.0978 Construction Materials Testing Services FIELD AND LABORATORY REPORT COVER PAGE Client: Ryan Homes 1450 Centrepark Blvd Suite 340 West Palm Beach, FL 33401 Project: Oakland Lake Subdivision Lot 1 18�� Dnl3 ,Fort Pierce, St. Lucie County, L As requested, Universal Engineering Sciences, Inc. (LIES) representative(s) performed construction materials testing and/or field inspection services on the above project. esting results and/or inspection observations are reported on the attached sheets. The contents of this package are sum I arized below: Scope of Work Work Order No. I Date I IType of Report 96106-1 1 04/23/2018 In -Place Density Test �eportw/Activity Record We hope this information is sufficient for your immediate needs. If you have any questions, please do not hesitate to contact the undersigned. Sincerely, Universal Engineering Sciences, Inc. Certificate of Authorization No. 00.000 L r v JUL 112018 .r "i• Richard E. Hoaglin, P.E. FLORIDA Professional Engineer No. 48796 ICC Email: cbugg@nvrinc.com; elibdhi@nvrinc.com; jomcalli@nvrinc.com; sign adn seal to ryan homes NIVERSAL UES 4, �tect No: 0310.1700251.0009 UES DOCS No: UES Report No: 96106-1 ARC 042318 ENGINEERIN SCIENCES On -Site Time (hrs): 0.50 Consultants In: Geotechnical Engin ring •Environmental Silences Lab Time (hrs): 0.00 GeophysicalServices- Materials sting - Threshold Inspection Travel Time (hrs): 0.25 01 Building Code Administration, Com liance Inspection & Plan Review Total Time (hrs): 0.75 820 Brevard Avenue, Rockledge, FL 329651 - P: 321.638.0808 - F: 321.638.0978 Client: Project: Date of Activity: Technician: Ryan Homes 1450 Centrepark BI1 West Palm Beach, f Oakland Lake Subd ,Fort Pierce, St. Luc Monday, 23 April, 21 Cliff Cherrnay Activity Record d Suite 340 IL 33401 ision Lot 21 County, FL 18 As requested, a Universal Engineering Sciences Technician was present at the above referenced project site for the purpose of earthwork testing for the House lot. While on site, the technician observed the general condition of the areas to be tested and performed 4 density test(s) for House lot. All test(s) were performed in accordanc with the ASTM D-6938 Nuclear Gauge Method and were found to meet the project compaction requirements of 95% of the m#imum dry density per ASTM D-1557. The Contractor was notified of the test Jilt 112018 or a copy was left for their records. UNIVE' SAL ENGINEERIN SCIENCES Consultants In: Geotechnical Engine e ing • Environmental Sciences Geophysical Services • Materials T fisting • Threshold Inspection Building Code Administration, Compl ance Inspection & Plan Review 820 Brevard Avenue, Rockledge, FL 32965 - P: 311.638.0808 - F: 321.638.0978 Client: Project: Area Tested: Type of Test: Technician: Requirements: Ryan Homes 1450 Centrepark Blvd Suite 340 West Palm Beach, L 33401 Oakland Lake Sub (vision Lot 21 ,Fort Pierce, St. Lucie County, FL House lot Field: ASTM D-69I38 Nuclear Gauge Method Lab: ASTM D15`37 Modified Proctor Cliff Cherrnay UE5 Project No: 0310.1700251.0009 UES DOCS No: UES Report No: 96106-1 DT 042318 Date of Test: 04/23/2018 95% of Proctor maxi um dry density. These tests apply to the fill and/or surficial soil conditions only and do not address the condition of the underlying soils below the tested depths. Test No. Location of Test Range Depth (inch) Proctor (2) Field Dry Density (PCF) Field Moisture % % Compaction Comments (3) 1 N/W Test 0-1 ft 12.00 21235 109.8 10.7 95 A 2 S/W Test 0-1 ft 12.00 21235 110.0 10.0 95 A 3 S/E Test 0-1 ft 1200. 21235 111.0 10.9 96 A 4 N/E Test 0- ft 12.00 21235 112.2 1 11.7 97 A (1) Ref. Datum: 0 = Top of Native I (3) Comments Key (2) Maximum Optimum A. Compaction meets min. requirements Proctor Dry Moisture B. Compaction does not meet min. requirements # Density Content C. Moisture does not meet requirements 21235 116.0 1�0.0 D. Recompaction required E_ Recomnacted. Retested_ Meets Reauirements