HomeMy WebLinkAboutEVALUATION REPORTSCANNED
BY
St Lucie County
QOTRINITYJERD
EVALUATION REPORT
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
RECEIVED
MAY 012018 EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization N9503
ST. Lucie County, Permitting 353 CHRISTIAN STREET, UNIT #13
-- OXFORD, CT 06478
(203) 262-9245
luation Report 037940.02.12-118
FL10674-1113
Date of Issuance: 02/06/2012
(740) 404-7829 1 Revision 8: 10/09/2017
SCOPE: 1
This Evaluation Report is issued under Rule161G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance lwith the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1 / R905.2.6.1. I
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinityiERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity) ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by: I
l
I
Robert J.M. Nieminen, P.E. �
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert
Nieminen, P.E. on 10/09/2017. This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity) ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaltation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
��TRINITYJERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category:
Sub -Category: n,.' ' phaltShingles
4
Compliance Statement: Owens Corning�Asphalt Roof Shir gle' as,p::roduced by Owens Corning, have demonstrated
compliance with the following sections of the 6th-Edition (2617).F6,ida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.5, R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1, R905.2.6.1 Wind Resistance 'ASTM D3161 2016
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2011
3. REFERENCES:
Entity Examination Reference Date
UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007
UL LLC (CER9626) Physicals & Wind Resistance 20120516-112453 05/16/2012
UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014
UL LLC (TST9628) Wind Resistance' 4786126532 02/10/2014
UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 '
UL LLC (TST9628) Physical Properties Classification letter 10/02/2015-
Miami-Dade (CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation Exp. 05/16/2020
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic and Supreme® are fiberglass reinforced, 3-tab asphalt roof shingles.
4.1.2 Berkshire® are fiberglass reinforced, 4-tab asphalt roof shingles.
4.1.3 DevonshireT°" are fiberglass reinforced, 5-tab asphalt roof shingles.
4.1.4 Duration®, TruDefinition® Duration®, Duration® Premium Cool, TruDefinition® Duration® Designer Color
Collection, TruDefinition®Oakridge®, Oakridge® and WeatherGuard® HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Hip & Ridge Shingles: '
4.2.1 Berkshire® Hip & Ridge Shingles, High Ridge, WeatherGuard® HP Hip & Ridge Shingles, ProEdge Hip & Ridge
Shingles and DuraRidgeT°" Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles.
4.3 Accessory Starter Strips:
4.3.1 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity[ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R8
Certificote ofAuthori:otion #9503 6" EDITION (2017) FBC NON-HVHZ EVALUATION F1.30674-1133
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 2 of 8
5.4 Wind Classification:
5.4.1 All Owens Corning asphalt shingles nc
and R905.2.6.1 to ASTM D3161, Class I
for use in all wind zones up to Vasd
requirements to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shing
Classified in accordance with FBC Tablc
shingles are acceptable for use in all wii
installation requirements to meet this N
5.4.3 Classification by ASTM D7158 applies t
roof height of 60 feet or less. Calcul;
outside these limitations. Contact the s
5.4.4 Refer to Owens Corning published infor
5.5 All products in the roof assembly shall F
6. INSTALLATION:
QOTRINITYIERD
:ed herein are Classified in accordance with FBC Tables 1507.2.7.1
and/or ASTM D7158, Class H, indicating the shingles are acceptable
150 mph (Vait = 194 mph). Refer to Section 6 for installation
as, Starter Strip Shingle and Starter Strip Plus noted herein are
1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
i zones up to Vasd = 150 mph (Vint = 194 mph). Refer to Section 6 for
nd rating.
exposure category B or C, as defined in FBC 1609.4.3, and a mean
:ions by a qualified design professional are required for conditions
ingle manufacturer for data specific to each shingle.
cation on wind resistance and installation limitations.
ve quality assurance audit in accordance with F.A.C. Rule 61G20-3.
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 61G20-3, per FBC 1507.2.3,1507.2.4 or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle iri accordance with FBC 1507.2.7 or R905.2.6, with the following
exceptions:
➢ Berkshire shingles require minimum five (5) nails per shingle.
➢ WeatherGuard® HP shingles require minimum six (6) nails per shingle.
➢ Devonshire'"" shingles require minimum six (6) nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing — Starter Strip Shingle and Starter Strip Plus:
Felt underlayment Deck
Sr
ut
Nai
2 =;
I SeN•sealin adhe:
ip positioned along
d Starter Strip shingle overhangs eaves and
edge
4� Lvil
Fait unilkir6ymerd Deck SeNyfemd
Weathe ock8
undetUymetn
Drip
edge,.
Naib located
r-i•from cave
av
YmtaSfintstarwStrip Pin SaH �he
With 61 removed Pin done ecave
Ste Strip FWavadongseaves and relm114'-314'
Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R8
Certificate of Authorization #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R33
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
1 Page 3 of 8
6.2.6 Minimum Nailing — Classic® & Supreme:
Seahnl:stdp.,
La tka de afiada
I
Standard Fastening Pattern
QOTWNITYIERD
Nornud Mansard or Area pem
Wind Aress Nigh Wind dsstanoa' y
Area pare vientos normales Apes viembs Insrtas
t' 2-
6 5W Exposure
Erpotividn
sealmrt Strip
Lath de sethdor
NONE
�110%Vi"
i
I
Seib 'ntstrip -
j La lha da salkdor
a .
ASphalt rool6ig'eenient
Cenaento de taeho da aslalto
Mansard or Steep Slope Fastening Pattern
6-Nail Fastening Pattern
Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-RS
Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 4 of 8
"I",NTINITYJERD
Mansard or Steep Slope Fastening Pattern
I
6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition®
Duration® Designer Color Collection:
4-Nail Fastening Patter
Sumtpl®rasantny'aroa rrtrtai
wu. iyq
+" 12" +r 1•
p...d®y8^.IW • •yw rn^W sswtas •
&1(ew
aNaw
F1 17 FL
Standard Fastening Pattern
F
Exterior Research and Design,LLC.
Certificate of Authorization #9503
6-Nall Fastening Pattern
- sinxaU ra+unhga WAM
nai4 rypeat
a.., co..oee..w • e�w.,.o . m..'.w. .
CtlB"
6EIt•
P F] F�
6-Nail Fastening Pattern
lea Greater Than 21:12
a—H.ftfaie,09e Wdih
r-ae0.+yp1W
Four I- ap06 or Asplua [t=Me Cemeat
Mansard or Steep Slope Fastening Pattern
I
6T" EDITION (201I7) FBC NON-HVHZ EVALUATION
Owens Corning Asphalt Roof Shingles
Evaluation Report 037940.02.12-118
F1.10674-1113
Revision 8:10/09/2017
Page 5 of 8
i
QOTRINITYIERD
6.2.1 Minimum Nailing —TruDefinition®Oakridge®, Oakridge®:
Standard Fastening Pattern
610 Pattern'
Esgrran_a dmt &'claws
r r
66/8'' Expasare. �r�' . 6.6/8"Exposule
Fxpo�iivdn de 66/6putg Eryasioadn dp 66/8p+rlg.
6-Nail Fastening Pattern
Fastoniog for Slopee Greater Than 21:12
6ar.eal,9h.nMig uw Me�ii
Flo F207-12'.
r rr nr
i
i
S.irr Ssre-
Fau.1-Span mMpeon e..Sag C.n. d
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailins — WeatherGuard® HP:
Exterior Research and Design, I.I.C.
Certificate of Authorization #9503
1�. 1 1�llh Meii.:V1�.
.t.• .; lielie�7lar�Y'Nilllis
. _ , . QiN w� iYiit+r il�dis
6To EDITION (2017) FBC NON-HVHZ EVALUATION
Owens Corning Asphalt Roof Shingles
Evaluation Report 037940.02.12-118
F1.10674-1113
Revision 8:10/09/2017
Page 6 of 8
l
Q0TPuN1TYjERD
6.3 Hip & Ridge Shingles:
6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuardo HP Hip and Ridge Shingles
and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions,
using four (4) nails per shingle. Installation'of DuraRidge"I Hip & Ridge Shingles shall comply with the
Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning
published information on wind resistanIce and installation limitations, including the use of hand -sealing for
wind warranties.
6.3.2 Fasteners shall be in accordance with Ithe manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing — Berkshire® Hip & Ridge and High Ridge:
Flg.'1
t- Prwdlkigwntl
Direction
6.3.4 Minimum Nailing — WeatherGuard® HP Hip and Ridge:
Fig.'A
preaaz�w�w
�—Dtrectbn -
t1.ilLv�.�—)qq �.
A:
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Fig.,C Hip & Ridge:Shingie Fastening
TopVbw,
"311S NJILS
r 2" P
C. E:posuro
17
6T" EDITION (2017) FBC NON-HVHZ EVALUATION
Owens Corning Asphalt Roof Shingles
Evaluation Report 037940.0Z.12-R8
F1.10674-1113
Revision 8:10/09/2017
Page 7 of 8
6.3.5 Minimum Nailing - ProEdge Hio & Ridge Shingles:
Prevailing
Wind Direction 8edent Strip
f 6' Expo ws
Cover
Fisten 7ye'�
niineEn with
Roo! Cement
�.. V TPJNITY I ERD
Standard—tt•—�
Fastening
Pattern
T
I h,r N. I'-T
12'
Sent
Vh'
8'Expo Ur
6.3.6 Minimum Nailing— DuraRidgel Hip & Ridge Shingles:
Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
�pyy Wlnd man
� Otneeadurnlm�edVxnt
Din�cu8ndd Pik �wdam�ta
4
i
OF 117xr
r 1/K�nsuppa�br 1,
Na
2j� • OenmCorciopSudia�l'- • �"'
I
V II.�G
wy
I
IF----
Ir—�
7. LABELING: j
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein. '
7i2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1 / R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS'
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC— QUA9625 ; (631) 546-2458; Kanchi.Agrawala-Dokania@ul.com
END OF EVALUATION REPORT -
Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R8
Certificate of Authorization #9503 6?" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 8 of 8