Loading...
HomeMy WebLinkAboutFOUNDATION PLANARCHITECT 5 CROSS SECTION 1 /4 1 0 2"x2" PICKETS @ 21" O.C. 2"x4" BOTTOM RAIL 4"x4" POSTS @ 6'-0" O.C. W/ (2) 1/2" dia THRU BOLTS RAILING DETAIL 1/2" = 1'-01, RAILING (REFER TO TYP RAILING (REFER TO FRAMING) TRPL BEAM (REFER TO FRAMING) LUS 28 HANGER (14) 7.85" RISERS (13) 10" TREADS 2"x12" STRINGER (TY x RISERS x12" TREADS IS 28 HANGER <12" RIM JOIST 1/2" DIA THRU BOLT �—ABU44 POST BASE W/ 1/2"x3 1/2" REDHEAD 7 STAIR SECTION Q 3/8 - 1 0 STRUCTURAL NOTES: 1. STRUCTURAL LUMBER TO BE HEM -FIR #2 GRADE OR BETTER W/ 1000 PSI MIN, FIBER STRESS VALUE 2. CONCRETE SLABS AND FOOTINGS TO BE 2500 PSI MIN 3. REINFORCING STEEL SHALL BE GRADE 60 OR BETTER W/ 30" MIN. LAP 4. CONCRETE COVER OVER REINFORCING STEEL: A. FOOTINGS: 3" B. BEAMS: 11/2" C. COLUMNS: 11/2" 5. FILL (SOIL) SHALL BE PLACED IN LIFTS NOT TO EXCEED 12" AND COMPACTED TO A MINIMUM OF 95% MODIFIED PROCTOR DENSITY 6. ALL COMPONENTS OF THIS STRUCTURE HAVE BEEN DESIGNED AND SELECTED TO WITHSTAND FORCES PER THE FLORIDA BUILDING CODE 2014 EDITION 7. DOOR & WINDOW ASSEMBLY COMPONENTS TO BE CERTIFIED BY MANUFACTURER FOR WIND FORCES PER THE FLORIDA BUILDING CODE 2014 EDITION PER WIND LOAD COMPLIANCE DESIGN PRESSURES 8. PRECAST/ PRESTRESSED CONCRETE LINTELS TO HAVE 6" MINIMUM BEARING. REFER TO LINTEL SCHEDULE FOR ADDITIONAL INFORMATION. 9. FOR METHOD OF ATTACHMENT OF DOORS & WINDOWS, REFER TO ATTACHED PRODUCT REVIEW AFFIDAVIT NOTE: ALL SIMPSON STRONG -TIE PRODUCTS IN CONTACT WITH TREATED LUMBER SHALL HAVE A MINIMUM Z-MAX COATING OR BETTER 2nd FLOOR ELECTRICAL PLAN 1/4" = 1'-0" - - 1st FLOOR ELECTRICAL PLAN 1/4"=)1'-01, - 2 CERTIFICATION FOR DESIGN LOAD COMPLIANCE 1. DESIGN CODE: FLORIDA BUILDING CODE 2017 EDITION 2. STRUCTURAL DESIGN: ENCLOSED 3. RISK CATEGORY: II EXPOSURE CATEGORY: B 4. DESIGN WIND VELOCITY: 160 MPH 5. MEAN ROOF HEIGHT: 22FT ROOF PITCH: 5/12 EXISTING 6. COMPONENTS & CLADDING DESIGN PRESSURE: PSF, BASED ON ACTUAL SQ. FT. @ 30' MRH (WORST CASE) ZONE 1: -22.0 ZONE 2: -32.0 ZONE 3: -60.0 ZONE 4: -28.0 ZONE 5: -34.0 GARAGE: -26.0 7. DESIGN LOADS: FLOOR 75 PSF ROOF/ DEAD: 15 PSF ROOF/ LIVE: 30 PSF 8. WERE SHEAR WALLS CONSIDERED FOR STRUCTURE? YES 9. IS A CONTINUOUS LOAD PATH PROVIDED? YES 10, DESIGN SOIL BEARING PRESSURE: 2000 PSF SOIL BORING TEST REQUIRED: NO IN -- — — — II T 7I RAIL T I � I 1=== IIII I I I I I I ) I I I 1�1II I I I I 1 1 13/4" 1 &G NECKING F I2 �112 � 1 W/ 1/2 IL D@ ° O. UE IIII I I I I I I I I I I I TA ER D E. III I 2"x1 "JOISTS016"10.C.1 I I I I I I I III I I I I I I I I I I I IT II I I I I 1 RAILING / I 14'-0" +/ P.T. 6"x6" WOOD POST (TYP) WOOD BEAM: (3) 2"x12" W/ 1/2" SPACER GLUED & NAILED @ 8" O.C. STAGGERED EACH WAY (TYP)- TYP JOIST HANGERS SINGLE JOISTS: SIMPSON LUS210 W/ (12) 10d NAILS DOUBLE BEAMS: SIMPSON LUS210-2 W/ (14) 10d NAILS EXISTING METAL TRIPLE BEAMS: SIMPSON LUS210-3 W/ (14) 10d NAILS BUILDING TO REMAIN 2nd FLOOR & FRAM 1/4" = 1'-011 ING PLAN t 1st FLOOR & FOUNDATION PLAN 1 /4" = 1' 0" SCANNED BY St Lucie County Architectonic In 806 DELAWARE AVENUE FORT PIERCE, FLORIDA 34950 T: 772 460 7751 F: 772 460 4244 W W W.ARCHITECTONICINC.COM STATE REG # AA26003348 COPY GHT2017 JECT STORAGE LOFT 5103 Seagrape Drive Fort Pierce, FL CLIENT PAUL MCCULLY O1J151ON �G i I�O�GO cy N`51 v� 5���$� (iOP �Oti��p �5p CONSULTANTS FILE C PO REGISTRATION Cf, Of. FL O ••'Qi JS 9 HA70 A 98 R� SD ARC AIA 898 REVISIONS NO. DATE REVISION 1 07/17/18 BLDG DEPT COMMENTS KEY PLAN SHEET TITLE / SHEET NUMBER FLOOR PLAN & NOTES Al mOO PROJECT NUMBER R1712' DATE 07/17/2011 ALI