Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department ® I Building &'Code Regulations Division 2300 Virginia Avenue, iFort Pierce, FL 34982 — (772) 462-1553 SCANNED i BY Certification for Des' ign Load Compliance St Lucie Country Project Name: Peters Res. Project Address: Lot 20, Diamond Sands. Permit #: Occupancy Type: Construction Type: i INSTRUCTIONS FOR USE: • This certification must be completed, signed, a • Submit (2) copies for residential, (3) copies for o New Residences (single or multi-famil o Residential Addition o Any accessory structure requiring a bit o Any non-residential structure. i sealed by the design professional of record. mmercial with all permit applications involving the following: ding permit Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion �f the local building official. Contact the # above for questions. 1. DESIGN CODE: Florida FBC 2017 2. 3. 4. 5. 6. 7 8. Structure Designed as (check one): Risk Category: _I X II III Design Wind Velocity 160 Mean Roof Height 34 Components & Cladding Design Press Zone 1: SEE Zone 2: PLANS Design Loads: Floor: 40 PSF Dock: N/A PSF Deck. N/A PSF Were Shear Walls Considered For Stru 9. Is A Continuous Load Path Provid S.USED: (complete all that apply) Code Fifth Edition with 20 14 Supplements using ASCE 7-10 X Enclosed Partially Enclosed . Open IV Exposure Category: B C X D mph' ASD X LRFD End Zone Width: 7.0 ft ft! Roof Pitch: 6 :12 Parapet: ZERO ft ure�s Used: (PSF, based on lNclft @ 15'MRH, clearly label on all plan openings): Zone 3: FOR Zone 4: OPN'G. Zone 5: PRES- Garage: SURFS. Roof/Dead: 25 PSF Roof/Live: 30 Balcony: 50LL PSF Stairs: 100 PSF Fence: N/A PSF Railings: N/A PSF cture? X Yes Not Applicable Explain Why Not: X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: N/A- PILING PSF Soil Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify That, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structurallelements depicted on these plans provide adequate resistance to the design fRK0-6� 1I ecifigdf �.. Robert E. Agsten III PE43205, CA8340 Print Name Cert # & Co. Cert Auth. 3205 = Agsten Engineering, Inc. .� S. jgnatyre,.9 e, nd S — 3000 Florida Blvd., #206, Delray Beach, FL 33483 i .,0• Company Name & Address. Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 = (772) 462-1553 Certification for Design Load Compliance Project Name: Peters Res. Project Address: Lot 20, Diamond Sands Permit #: Occupancy Type: Construction Type: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o' Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of thellocal building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida FBC 2017 Code Fifth Edition with 20 14 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed Partially Enclosed, Open., 3. Risk Category: _I X II III IV Exposure Category: B C X D 4.. Design -Win d Velocity 160 mph ASD X LRFD End Zone Width: 7•0 ft• 5. Mean Roof Height 34 ft I Roof Pitch: 6 :12 Parapet: ZERO. ft 6. Components & Cladding Design Pressures Used I (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: SEE Zone 2: PLANS Zone 3: FOR Zone 4: OPN'G. Zone 5: PRES- Garage: SORES. 7. Design Loads: Floor: 40 PSF Roof/Dead: 25 PSF Roof/Live: 30 Balcony:. 50LL PSF Dock: NSA PSF Deck: Nip` PSF Stairs :l 100 PSF Fence: Nip` PSF Railings: Nip` ' PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yesl INot Applicable Explain Why Not: 10. Design Soil Bearing Pressure: N/A- PILING PSFJ Soil Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces sRgri'F 48.1 I I I/ ��'C E. AC'`S%' �Robert E. Agsten III PE43205, CA8340 ��CEN Print Name Cert # & Co. Cert Auth. No. a % ' Agsten Engineering, Inc. ig� ture, te, nd 5 al 3600 Florida Blvd., #206, Delray Beach', FL 33483 F18 �Company Name & Address. Revi3// kj' ZIP �/ .. • N�j� !��� TONAL �E,\�o .. ; • .. .. ,