Loading...
HomeMy WebLinkAboutENGINEERING 8-30-18UUULUG(1I11UW IX VullbtlIRaIVI I IVIGR0I1cuo -`ngineerin , Testing, & Inspection Hutting Environmental Services fiE Engineers Offices throughout the state of Florida of Florida Inca Established 1967 www.nu ' engineers.com info@nuttingengineers.com Your Projectis Our Commitment SCANNED bw�j August 30, 2018 1 BY � Mr. John Butler t Lu ie County Bodax Foundations, Inc. 1101 NW 551h Street Ft. Lauderdale, Florida 33309 Subject: Report of Augercast Pile Installation Monitoring Proposed Residence and Pool Lot 20, 8036 South Ocean Drive Jensen Beach, Florida Dear Mr. Butler: �1,1(1,c-,- 00 /7 t2 Nutting Engineers of Florida, Inc. (NE) has completed observation of augercast piling operations for the proposed residence and pool at the subject site. Bodax Foundations, Inc. installed cast -in -place augured piles for support of the proposed construction. Bodax Foundations, Inc. installed a' total of 83, 16-inch diameter augercast piles for the project. The piles were installed from August 8, 2018 to August 10, 2018. Please refer to the pile plan for the numbering provided to our office. The pile size and depth recommendations were based upon our review of the Report of Geotechnical Exploration prepared by GFA International dated April 5, 2018. The pile installation characteristics of each pile are presented in the attached Pile Installation Data. Identification of each pile location followed by the pile number is shown on the Pile Location Plans attached. Each pile record in the attached summary tables shows the following information: ■ RECORD NUMBER IN CHRONOLOGICAL ORDER ■ THE PILEjNUMBER (AS FOUND ON ATTACHED PLANS) ■ THE DIAMETER OF THE PILE ■ THE LENGTH OF PILE FROM GROUND SURFACE TO TIP ■ THE THEORETICAL VOLUME OF GROUT FOR THE PILE ■ THE NUMBER OF PUMP STROKES FOR THE PILE ■ THE ACTUAL VOLUME OF GROUT FOR THE PILE ■ THE GROUT FACTOR ■ THE DATE OF INSTALLATION ■ THEREINEOIZCEMENZT�E� ■ AND GENERAL COMMENTS AS NEEDED The drilling operations were monitored in the field by our field engineer and inspector in order to approximately determine the type of material being penetrated. 1 1310 Neptune Drive • Boynton Beach, Florida 33426 • (661) 736-4900 • Fax (561) 737-9976 Broward (954) 941-8700 • Port St. Lucie (772) 408-1050 • Miami Dade (305) 624-0060 This identification was done based on the augering time, the materials received during the drilling operations and the relative hardness of the soils/rocks as indicated by the vibration or "chattering" of the hydraulic lines. The augercast piles were installed to depths of twenty-six to twenty-eight feet below the existing ground surface of approximately. The piles were designed for an allowable compressive capacity of 40 tons for the residence and 15 tons for the pool as required by the structural specifications and the recommendations made by others. i Generally, during the installation of the piles, easy drilling was observed from the ground level to approximately twenty-five feet. Below this depth range hard drilling was encountered to the final tip depth. i All house and pool piles received steel reinforcement consisting of frill length cage with 6, #7 reinforcing bars with #3 ties spaced 12-inches on'center the full length of the pile as stated in the structural documents. We also note that five pool piles were battered 15-degrees as stated on the pile location plan. I Upon completion of this inspection process, and review of the recorded data, it is our opinion that the augercast piles installed for the residence attained the required design compressive capacity of 40 tons and the pool attained the required compressive capacity of 15 tons. The piles that were presently installed were constructed in substantial compliance with the plans and specifications. i Drilling Condition Note: We note that due to very loose sand soils throughout the subsurface profile at the site, in order to develop acceptable piles, the placement of grout well beyond typical amounts were needed within many piles installed at the site. The piling company attempted to minimize the amount of grout placed as best as possible; however, site conditions still resulted in excessive grout being needed within those piles. Upon completion of this inspection process, and review of the recorded data, it is our opinion that the augercast piles installed for the project attained the required design compressive capacity of 35 tons. The piles that were presently installed were constructed in substantial compliance with the plans and specifications. i I We note that it was monitored and ensured that the piles began installation at the survey locations provided in the field. If during drilling operations it was discovered that gross deviations from original locations have occurred, the deviation was attempted to be rectified. Nutting Engineers is not responsible for minor deviations which have occurred during drilling operations, along with incorrect surveyed pile locations during piling installation. We also note that some deviations may be due to the augerdrill shifting when attempting to drill through the hard frock or other encountered debris conditions. This condition is beyond the control of the site inspector and undersigned engineer. Our client for this geotechnical evaluation was: Mr. John Butler Bodax Foundations, Inc. 1101 NW 55n` Street Ft. Lauderdale, Florida 33309 Nutting E Engineers of Florida Inc1 Established 1967 Your Project is Our Commitment 2 NE shall bear no liability for the implementation of recommended inspection and testing services as described in this report if implemented by others. NE has no ability to verify the completeness, accuracy or proper technique of such procedures if performed by others. The Geotechnical Engineer warrants (that the findings, recommendations, specifications, or professional advice contained herein, have been presented after being prepared in accordance with general accepted professional practice in the field of foundation engineering, soil mechanics and engineering geology. No other warranties are implied or expressed. We appreciate the opportunity to provide these services for you. if you should have any questions, or if we can be of any further assistance iri this matter, please feel free to contact us. Senidr Geotechn cal Engineer Attachm--nts: Pile Location Plan Pile Instailation Records LTR BODAX PROP RES 8036 S-OCN DR JENSENi BCH ACP CEG I Nutting r3lEngineers of Florida Inc I Established 1967 YourProjectis OurCommltment 3 SCHEDULE DP-V Wr DC. SNrRr FOR 6'" WALL FOR Wg5. PERMIT SET PiAtti VAiW MOOR MINGPLAN TIUS DRAWING IS ANINSTRUDMENT OF Nm W g `J N� 5 '< O i� P O .a ' O .e �J y to o s �t �� rd S ✓o F+ I o r c •ro � C '� �' pin°�� i-+ F1 nD i A0° DD Vl AND IS THE PROPERTY OF COATIS. SINCLAM INC. AND IS NOT TO BGREPRODUCED IN WHOLE OR IN•PART WTCHOUT TBE EXPRESS WRITTENPERMISSION OF COATIS - SINCLA.IR, INC. POOL' SPA PLAN FOR: Private Residence C1[ W-rlS _ STNCLAM, INC. e• U822559 N. MMTARY TRAIL, SUITE 3 LOT 20, DIAMOND SANDS PALM BEACH GARDENS, FL 33418 JENSEN BEACH, FL PII. 561-630-8534 FAX 561-630-8557 C.O.A. NO.5725 Stephen AT Sinclalr, P.E. Flarlda License NO.35631 EODAX FOUNDATION PROPOSED RESIDENCE 8036 S OCEAN DRIVE JEN,SEN BEACH, FLORIDA PILE LOG DATA OF AUGERCAST PILE INSTALLATION NUTTING ENGINEERS OF FLORIDA, INC. Record No. Pile No. Pile Dia. (in) Pile Length (ft) Theoretic. Pile Volume (ft) Pump Strokes Total Volume of Grout pumped fta Grout Factor Date Installed Remarks 1 14 16.0 28 39.1 44 48.4 1.24 08/08/18 2 12 16.0 28 39.1 45 49.5 1.27 08/08/18 3 11 16.0 26 36.3 50 55.0 1.52 08/08/18 4 9 16.0 26 36.3 49 53.9 1.48 08/08/18 5 8 16.0 26 36.3 53 58.3 1.61 08/08/18 6 7 16.0 26 36.3 62 68.2 1.88 08/08/18 Redrill 7 6 16.0 26 36.3 58 63.8 1.76 08/08/18 8 18 16.0 28 39.1 48 52.8 1.35 08/08/18 9 17 16.0 28 '39.1 52 57.2 1.46 08/08/18 10 13 16.0 28 '39.1 46 50.6 1.29 08/08/18 11 10 16.0 28 ; 39.1 50 55.0 1.41 08/08/18 12 25 16.0 28 '39.1 49 53.9 1.38 08/08/18 13 24 16.0 28 39.1 50 55.0 1.41 08/08/18 14 38 16.0 28 39.1 43 47.3 1.21 08/08/18 15 49 16.0 28 39.1 44 48.4 1.24 08/08/18 16 57 16.0 28 39.1 51 56.1 1.43 08/08/18 17 69 16.0 28 39.1 48 52.8 1.35 08/08/18 18 59 16.0 28 39.1 51 56.1 1.43 08/08/18 19 58 16.0 28 39.1 50 55.0 1.41 08/08/18 20 56 16.0 28 39.1 48 52.8 1.35 08/08/18 21 50 16.0 28 39.1 52 57.2 1.46 08/08/18 22 23 16.0 28 39.1 59 64.9 1.66 08/08/18 23 37 16.0 28 39.1 46 50.6 1.29 08/08/18 24 70 16.0 28 39.1 44 48.4 1.24 08/08/18 25 27 16.0 28 39.1 51 56.1 1.43 08/08/18 26 28 16.0 28 39.1 46 50.6 1.29 08/08/18 27 30 16.0 28 39.1 44 48.4 1.24 08/08/18 28 32 16.0 28 39.1 43 47.3 1.21 08/08/18 29 45 16.0 28 39.1 46 50.6 1.29 08/08/18 30 77 16.0 28 39.1 43 47.3 1.21 08/09/18 Pool 31 76 16.0 28 39.1 42 46.2 1.18 08/09/18 Pool 32 79 16.0 28 39.1 47 51.7 1.32 08/09/18 Pool 33- -46- 6-0- --28- ---39.1 46 -50-6- 1.29- -08/09/48- 34 54 16.0 28 39.1 42 46.2 1.18 08/09/18 35 78 16.0 28 39.1 48 52.8 1.35 08/09/18 Pool 36 53 16.0 28 39.1 44 48.4 1.24 08/09/18 37 83 16.0 28 39.1 44 48.4 1.24 08/09/18 Pool 38 80 16.0 28 39.1 43 47.3 1.21 08/09/18 Pool Nutting E Engineers of Florida Inc.I Established 1967 vODAX FOUNDATION PROPOSED RESIDENCE 8036 S OCEAN DRIVE JENSEN BEACH, FLORIDA PILE LOG DATA OF AUGERCAST PILE INSTALLATION NUTTING ENGINEERS OF FLORIDA, INC. Record No. Pile No. Pile Dia. (in) pile Length (ft) Theoretic. Pile Volt3me (f) Pump Strokes Total Volume ofGrout Grout pumped ft3 Factor Date Installed Remarks 39 31 16.0 28 39.1 43 47.3 1.21 08/09/18 40 62 16.0 28 39.1 44 48.4 1.24 08/09/18 41 75 16.0 28 3.0.1 43 47.3 1.21 08/09/18 42 63 16.0 28 39.1 43 47.3 1.21 08/09/18 43 44 16.0 28 39.1 42 46.2 1.18 08/09/18 44 29 16.0 28 39.1 46 50.6 1 1.29 08/09/18 45 41 16.0 28 39.1 43 47.3 1.21 08/09/18 46 42 16.0 28 39.1 44 48.4 1.24 08/09/18 47 52 16.0 28 39.1 45 49.5 1.27 08/09/18 48 61 16.0 28 !39.1 49 53.9 1.38 08/09/18 49 82 16.0 28 '39.1 43 47.3 1.21 08/09/18 Pool 50 43 16.0 28 '39.1 45 49.5 1.27 08/09/18 51 33 16.0 28 39.1 43 47.3 1.21 08/09/18 52 35 16.0 28 39.1 44 48.4 1.24 08/09/18 53 47 16.0 28 39.1 46 50.6 1.29 08/09/18 54 48 16.0 28 39.1 42 46.2 1.18 08/09/18 55 36 16.0 28 39.1 43 47.3 1.21 08/09/18 56 34 16.0 28 39.1 42 46.2 1.18 08/09/18 57 20 16.0 28 39.1 44 48.4 1.24 08/09/18 58 21 16.0 28 39.1 43 47.3 1.21 08/09/18 59 55 16.0 28 39.1 42 46.2 1.1.8 08/09/18 60 74 16.0 28 39.1 48 52.8 1.35 08/09/18 61 81 16.0 28 39.1 45 49.5 1.27 08/10/18 Pool 62 60 16.0 28 39.1 47 51.7 1.32 08/10/18 63 73 16.0 28 39.1 52 57.2 1.46 08/10/18 64 72 16.0 28 39.1 46 50.6 129 08/10/18 65 71 16.0 28 39.1 43 47.3 1.21 08/10/18 66 68 16.0 28 39.1 43 47.3 1.21 08/10/18 67 67 16.0 28 39.1 42 46.2 1.18 08/10/18 68 66 16.0 28 39.1 42 46.2 1.18 08/10/18 69 65 16.0 28 39.1 42 46.2 1.18 08/10/18 70 64 16.0 28 39.1 43 47.3 1.21 08/10/18 71 39 16.0 28 39.1 42 46.2 1.18 08/10/18 -7� �6 16U -28- �-9.1 - 4 -51:7- 1-32- 08TTU/1-8- 73 22 16.0 28 39.1 43 47.3 1.21 08/10/18 74 5 16.0 28 39.1 45 49.5 1.27 08/10/18 75 15 16.0 28 39.1 43 47.3 1.21 08/10/18 76 19 16.0 28 39.1 40 44.0 1.13 08/10/18 Hutting E Engineers of Florida Inc. I Established 1967 �aDAX FOUNDATION PROPOSED RESIDENCE 8036 S OCEAN DRIVE JENSEN BEACH, FLORIDA PILE LOG DATA OF AUGERCAST PILE INSTALLATION NUTTING ENGINEERS OF FLORIDA, INC. Theoretic. Total Record Pile No. Pile Dia. pile Length Pile Pump Volume ofGrout Grout Date Remarks No. (in) (ft) Volume Strokes Pumped Factor Installed (ft3) ft 77 1 16.0 28 30.1 42 46.2 1 1.18 08/10/18 78 2 16.0 28 39.1 42 46.2 1.18 08/10/18 79 3 16.0 28 39.1 41 45.1 1.15 08/10/18 80 4 16.0 28 39.1 46 50.6 1.29 08/10/18 81 16 16.0 28 39.1 41 45.1 1.15 08/10/18 82 40 16.0 28 39.1 47 51.7 1.32 08/10/18 83 51 16.0 28 j39.1 45 49.5 1.27 08/10/18 Total linear feet drilled 2314 ; Total Grout (yd) 155 ! PILE LOG FL BODAX PROPOSED RES 8036 S OCEAN DR JENSEN ACP Minimum depth drilled 26 Maximum depth drilled 28 Nutting E Engineers of Florida Inc. I Established 1967 �= Hutting Engineers, of Florida Inc. I Established 1967 YourProjectis Our Commitment August 30, 2018 ueolecnnicai & yonstrucuon maienais Engineering, Testing, & Inspection Environmental Services Offices throughout the state of Florida www.nuttingengineers.com info@nuttingengineers.com 170 6---(9033 Mr. John Butler Bodax Foundations, Inc. 1101 NW 55th Street Ft. Lauderdale, Florida 33309 Subj ect: Report of Augercast, Pile Installation Monitoring Proposed Residence and Pool Lot 20, 8036 South Ocean Drive Jensen Beach, Florida i Dear Mr. Butler: ' i Nutting Engineers of Florida, Inc; (NE) has completed observation of augercast piling operations for the proposed residence and pool at the subject site. Bodax Foundations, Inc. installed cast -in -place augured piles for support of the proposed construction. Bodax Foundations, Inc. installed a total of 83, 16-inch diameter augercast piles for the project. The piles were installed from August 8, 2018 to August 10, 2018. Please refer to the pile plan for the numbering provided to our office. The pile size and depth recommendations were based upon our review of the Report of Geotechnical Exploration prepared by GFA International dated April 5, 2018. The pile installation characteristics of each pile are presented in the attached Pile Installation Data. Identification of each pile location followed by the pile number is shown on the Pile Location Plans attached. Each pile record in the attached summary tables shows the following information: ■ RECORD NUMBER IN CHRONOLOGICAL ORDER ■ THE PILE NUMBER (AS FOUND ON ATTACHED PLANS) ■ THE DIAMETER OF THE PILE ■ THE LENGTH OF PILE FROM GROUND SURFACE TO TIP ■ THE THEORETICAL VOLUME OF GROUT FOR THE PILE ■ THE NUMBER OF PUMP STROKES FOR THE PILE ■ THE ACTUAL VOLUME OF GROUT FOR THE PILE ■ THE GROUT FACTOR ■ THE DATE OF INSTALLATION ■ TI3E REINEORCBMENT�YPE� ■ AND GENERAL COMMENTS AS NEEDED The drilling operations were monitored in the field by our field engineer and inspector in order to approximately determine the type of material being penetrated. 01 1310 Neptune Drive - Boynton Beach, Florida 33426 - (561) 736-4900 • Fax (561) 737-9975 Broward (954) 941-8700 - Port St. Lucie (772) 408-1050 - Miami Dade (305) 624-0060 I This identification was done based; on the augering time, the materials received during the drilling operations and the relative hardness of the soils/rocks as indicated by the vibration or "chattering" of the hydraulic lines. The augercast piles were installed to depths of twenty-six to twenty-eight feet below the existing ground surface of approximately. The piles were designed for an allowable compressive capacity of 40 tons for the residence and 15 tons for the pool as required by the structural specifications and the recommendations made by others. Generally, during the installation' of the piles, easy drilling was observed from the ground level to approximately twenty-five feet. Below this depth range hard drilling was encountered to the final tip depth. All house and pool piles received Isteel reinforcement consisting of full length cage with 6, #7 reinforcing bars with #3 ties spaced 12-inches on center the full length of the pile as stated in the structural documents. We also note that five pool piles were battered 15-degrees as stated on the pile location plan. Upon completion of this inspection process, and review of the recorded data, it is our opinion that the augercast piles installed for the residence attained the required design compressive capacity of 40 tons and the pool attained the required compressive capacity of 15 tons. The piles that were presently installed were constructed in substantial compliance with the plans and specifications. Drilling Condition Note: We note that due to very loose sand soils throughout the subsurface profile at the site, in order to develop acceptable piles, the placement of grout well beyond typical amounts were needed within many piles installed at the site. The piling company attempted to minimize the amount of grout placed as best as possible; however, site conditions still resulted in excessive grout being needed within those piles. Upon completion of this inspection process, and review of the recorded data, it is our opinion that the augercast piles installed for the project attained the required design compressive capacity of 35 tons. The piles that were presently installed were constructed in substantial compliance with the plans and specifications. We note that it was monitored and ensured that the piles began installation at the survey locations provided in the field. If during drilling operations it was discovered that gross deviations from original locations have occurred, the deviation was attempted to be rectified. Nutting Engineers is not responsible for minor deviations which have occurred during drilling operations, along with incorrect surveyed pile locations during piling installation. We also note that some deviations may be due to the augerdrill shifting when attempting to drill through the hard rock or other encountered debris conditions. This condition is beyond the control of the site inspector and undersigned engineer. Our client for this geotechnical evaluation was: Mr. John Butler Bodax Foundations, Inc. 1101 NW 55t' Street Ft. Lauderdale, Florida 3;3309 Nutting E Engineers. of Florida Inc I Established 1967 YourProjectis Ourcommitmeot 2 NE shall bear no liability for the implementation of recommended inspection and testing services as described in this report if implemented by others. NE has no ability to verify the completeness, accuracy or proper technique of such procedures if performed by others. i The Geotechnical Engineer warrants that the findings, recommendations, specifications, or professional advice contained herein, have been' presented after being prepared in accordance with general accepted professional practice in the field of foundation engineering, soil mechanics and engineering geology. No other warranties are implied or expressed. We appreciate the opportunity to provide these services for you. If you should have any questions, or if we can be of any further, assistance in this matter, please feel free to contact us. Fuld S NU YINEL , LSIDA, C. C S ler-E. G re , E. #6"47 Senior Geot6cliri.cal Engineer Attachments: Pile Location Plan Pile Installation Records LTR BODAX PROP RES 8036 S-OCN DR JENSEN BCH ACP CEG Nutting E Engineers of Florida Inc I Established 1967 Your Project is Our Commitment 3 I BM (flan T--57.57U I RF3•WWCs ggs 4)'o a g• fA. p 51 •b eg•TD 1 4)q ob•TD, 6)Ya •b'TO. 0". PR. ^� d)K eg•tA 8 4J i Nms Ikwu ea. M?Rt W M w,te FEa'D. FOR 5• LT11 WALL FOR 6TRI r'1 5 n• 5 5• C� tON i + G91 GBf x 0 0 h � • i 7 5 6• ' V l�� Q � I ��•�• • �y I I I � I �6 1�1 ry t ,y 4'-b• 5'•b' G96 m I I m 1'YI LLnn l,. Zvi ,BB 6 6i na 4. ' rY / = m � 6 n � � � � •� TFzwaw c-ev z' n Y I �ly s �o I � � A Joofto.1710110 C 11 I (� I PERMIT SET e M 4M CAM m I y�. �Brl nasrErrB�au�u�ra subw �' Ra 3000P1adda9miaead � I b'•b• i J D&1W *F 3-14M T FL�R ALL PJLING PLAN f' O!C• f S(eSLjlly4'i',0' � i II THUS DRAWING IS ANINSTRUMENT OF ab N15 phi e_�V., 'o`� M 0 I..-�._- ti 19 \ 1 v n� ' ` r"�t�'$ Y }� 2 i._, ✓ p I I A i F� e Q F+ I a J� y VI b AND IS THE PROPERTY OF COATIS-SINCLAIR,INC AND IS NOT TO DEREPRODUCED IN WHOLE Olt INTARTWITHOUTTHE EXPRESS WRITTEN PERMISSION OF CURTIS - SINCLAM INC. POOLI SPA PLAN FOR: CYJR'A'xS - SlNCLA M, INC. Private residence 8259 N. MILITARY TRAIL, SUITE 3 LOT 20, DIAMOND SANDS PALM BEACH GARDENS, FL 33418 PH. 561-630-8534 FAX 561-630-8557 JENSEN BEACH, FL Stephen TvL , PE. C.O.A. NO.5725 Florida l icenseclnlrNo. 35631 BODAX FOUNDATION PROPOSED RESIDENCE 8036 S OCEAN DRIVE JENSEN BEACH, FLORIDA PILE LOG DATA OF AUGERCAST PILE INSTALLATION NUTTING ENGINEERS OF FLORIDA, INC. Record No. Pile No. Pile Dia. (in) pile Length (ft) Theoretic. Pile Volume (ft3) Pump Strokes Total Volume ofGrout Grout Pumped ft Factor Date Installed Remarks 1 14 16.0 28 39.1 44 48.4 1.24 08/08/18 2 12 16.0 28 39.1 45 49.5 1.27 08/08/18 3 11 16.0 26 36.3 50 55.0 1.52 08/08/18 4 9 16.0 26 36.3 49 53.9 1.48 08/08/18 5 8 16.0 26 36.3 53 58.3 1.61 08/08/18 6 7 16.0 26 36.3 62 68.2 1.88 08/08/18 Redrill 7 6 16.0 26 36.3 58 63.8 1.76 08/08/18 8 18 16.0 28 39.1 48 52.8 1.35 08/08/18 9 17 16.0 28 39.1 52 57.2 1. 1.46 08/08/18 10 13 16.0 28 39.1 46 50.6 1.29 08/08/18 11 10 16.0 28 39.1 50 55.0 1.41 08/08/18 12 25 16.0 28 39.1 49 53.9 1.38 08/08/18 13 24 16.0 28 39.1 50 55.0 1.41 08/08/18 14 38 16.0 28 39.1 43 47.3 1.21 08/08/18 15 49 16.0 28 39.1 44 48.4 1.24 08/08/18 16 57 16.0 1 28 39.1 51 56.1 1.43 08/08/18 17 69 16.0 28, 39.1 48 52.8 1.35 08/08/18 18 59 16.0 28' 39.1 51 56.1 1.43 08/08/18 19 58 16.0 28, 39.1 50 55.0 1.41 08/08/18 20 56 16.0 28 39.1 48 52.8 1.35 08/08/18 21 50 16.0 28 39.1 52 57.2 1.46 08/08/18 22 23 16.0 28 39.1 59 64.9 1.66 08/08/18 23 37 16.0 28 39.1 46 50.6 1.29 08/08/18 24 70 16.0 28 39.1 44 48.4 1.24 08/08/18 25 27 16.0 28 39.1 51 56.1 1.43 08/08/18 26 28 16.0 28 39.1 46 50.6 1.29 08/08/18 27 30 16.0 28 39.1 44 48.4 1.24 08/08/18 28 32 16.0 28 39.1 43 47.3 1.21 08/08/18 29 1 45 16.0 28 39.1 46 50.6 1.29 08/08/18 30 77 16.0 28 39.1 43 47.3 1.21 08/09/18 Pool 31 76 16.0 28 39.1 42 46.2 1.18 08/09/18 Pool 32 79 16.0 28 39.1 47 51.7 1.32 08/09/18 Pool 33- 46--16.0--- 28- 39-1- 46 --50:6 1.29 -08/09/48- 34 54 16.0 28 39.1 42 46.2 1.18 08/09/18 35 1 78 16.0 28 39.1 48 52.8 1.35 08/09/18 Pool 36 53 16.0 28 39.1 44 48.4 1.24 08/09/18 37 83 16.0 28 39.1 44 48.4 1.24 08/09/18 Pool 38 80 16.0 28 39.1 43 47.3 1.21 08/09/18 Pool Nutting E Engineers of Florida Inc.1 Established 1967 BODAX FOUNDATION PROPOSED RESIDENCE 8036 S OCEAN DRIVE JENSEN BEACH, FLORIDA PILE LOG DATA OF AUGERCAST PILE INSTALLATION NUTTING ENGINEERS OF FLORIDA, INC. Record No. Pile No. Pile Dia. (in) pile Length (ft) Theoretic. Pile Volume (ft3) Pump Strokes Total Volume ofGrout Grout Pumped ft Factor Date Installed Remarks 39 31 16.0 28 '39.1 43 47.3 1.21 08/09/18 40 62 16.0 28 39.1 44 48.4 1.24 08/09/18 41 75 16.0 28 39.1 43 47.3 1.21 08/09/18 42 63 16.0 28 39.1 43 47.3 1.21 08/09/18 43 44 16.0 28 39.1 42 46.2 1.18 08/09/18 44 29 16.0 28 39.1 46 50.6 1.29 08/09/18 45 41 16.0 28 39.1 43 47.3 1.21 08/09/18 46 42 16.0 28 39.1 44 48.4 1.24 08/09/18 47 52 16.0 28 39.1 45 49.5 1.27 08/09/18 48 61 16.0 28 39.1 49 53.9 1.38 08/09/18 49 82 16.0 28 39.1 43 47.3 1.21 08/09/18 Pool 50 43 16.0 28 39.1 45 49.5 1.27 08/09/18 51 33 16.0 28 39.1 43 47.3 1.21 08/09/18 52 35 16.0 28 39.1 44 48.4 1.24 08/09/18 53 47 16.0 28 39.1 46 50.6 1.29 08/09/18 54 48 16.0 28 39.1 42 46.2 1.18 08/09/18 55 36 16.0 28 39.1 43 47.3 1.21 08/09/18 56 34 16.0 28 39.1 42 46.2 1.18 08/09/18 57 20 16.0 28,' 39.1 44 48.4 1.24 08/09/18 58 21 16.0 28; 39.1 43 47.3 1.21 08/09/18 59 55 16.0 1 281 39.1 42 46.2 1.18 08/09/18 60 74 16.0 28 39.1 1 48 52.8 1.35 08/09/18 61 81 16.0 28 39.1 45 49.5 1.27 08/10/18 Pool 62 60 16.0 28 39.1 47 51.7 1.32 08/10/18 63 73 16.0 28 39.1 52 57.2 1.46 08/10/18 64 72 16.0 28 39.1 46 50.6 1.29 08/10/18 65 71 16.0 28 39.1 43 47.3 1.21 08/10/18 66 68 16.0 28 39.1 43 47.3 1.21 08/10/18 67 67 16.0 28 39.1 42 46.2 1.18 08/10/18 68 66 16.0 28 39.1 42 46.2 1.18 08/10/18 69 65 16.0 28 39.1 42 46.2 1.18 08/10/18 70 64 16.0 28 39.1 43 47.3 1.21 08/10/18 71 39 16.0 28 39.1 42 46.2 1.18 08/10/18 26 �fi 0 -28- -3-1- ----47 51:7- -0S/1-071V 73 22 16.0 28 39.1 43 47.3 1.21 08/10/18 74 5 16.0 28 39.1 45 49.5 1.27 08/10/18 75 15 16.0 28 1 39.1 43 47.3 1.21 08/10/18 76 19 16.0 28 1 39.1 40 44.0 1.13 08/10/18 Nutting T310 Engineers of Florida Inc. I Established 1967 9 BODAX FOUNDATION PROPOSED RESIDENCE 8036 S OCEAN DRIVE JENSEN BEACH, FLORIDA PILE LOG DATA OF AUGERCAST PILE INSTALLATION NUTTING!ENGINEERS OF FLORIDA, INC. Record No. Pile No. Pile Dia. (in) Pile Length (ft) Theoretic. Pile Vol,bme (ft3) Pump Strokes Total Volume of Grout Pumped ft Grout Factor Date Installed Remarks 77 1 16.0 28 39.1 42 46.2 1.18 08/10/18 78 2 16.0 28 39.1 42 46.2 1.18 08/10/18 79 3 16.0 28 39.1 41 45.1 1.15 08/10/18 80 4 16.0 28 39.1 46 50.6 1.29 08/10/18 81 16 16.0 28 39.1 41 45.1 1.15 08/10/18 82 1 40 16.0 28 $9.1 1 47 51.7 1.32 08/10/18 83 1 51 16.0 28 39.1 1 45 49.5 1.27 08/10/18 Total linear feet drilled 2314 Total Grout (yd) 155 PILE LOG FL BODAX PROPOSED RES 8036 S OCEAN DR JENSEN ACP Minimum depth drilled —t-28 26 Maximum depth drilled Hutting o Engineers of Florida Inc. Established 1967 1498r7�'-'20:1r7