Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTS• Miami -Dade County Page 1 of 1 ' SCANNED Miami -Dade County Building B 0 ,, Dip cip.. aC Product Information for N.O.A. 17-1221.15 }a Po0feei3 Vno(or(( .�ecLmTS NOA 17-,221.15 t (library/productcontrollnoa117122115.pdf ) Superseded —BY File Status File'I pproved File Classification High velocity hurricane zone Category Roofing Subcategory Undel layments Material Asphalt Applicant Gardner Asphalt Cor oratior March/28/2023 Expiration_Date Impact —Rate Unselelcted / Unknown Maximum_Design_Pressure_Positive 0 Maximum —Design —Pressure —Negative 0 Description Gardner Underlayments Green —Sustainable —Attributes NONE I For a detailed description on the File Status, click "the NOA File Status Key. (/buitdino/pc-result key apn.asp ) Page Last Edited: Wed Jan 25, 2017 10:40:27 AM I s.� COUNTY I http://www.miamidade. gov/building/pc-result_app. asp?fldNOA=17-1221.15 &BasicS earch... 4/24/2018 -.Lv%LUL111-YCNiV VVLU1tj' rup i OL i Ifi'lami-Bade County Building Product Control Search Results QUERY PARAMETERS File Ctessificatiom i High velocity hurricane zone Applicant: Gardner Asphalt Corporation Category. Roofing Subcategory: Underlayments Material: None Impact Rate: None Maximum Design Pressure(*): 0.00 Nta dmum Design Pressure(-): 0.00 NOA APPLICANT CATMORY SUBCATEGORY MATEMAL DESOMMOR INPAOT MDPr MD0. CLAeapEec t7tPtnL'a '17-1�1 16 rb GartnerAeMeR Roofing Undedeymems Asphalt Gardner UnseWed 1 0 0 High velocity March CORMOM ^ cam+:!! damn aAUW Underlaymerds Unknown hurricane zone 282023 acc a7as.l008031 Rom 1 ru a uuwsaa owmpoon on the Elie stems, dick the N_OA Flle Statue i(ev I/bt no/x ac�it Ray anc oc 1 Page Last Mad: Wed Jan 28, 201710:40:27 AM I httP://www.miamidade.gov/buildinWpe.resu'tL-aPP-asP?fdNOA=&Classification—l%2CHi... 4/17/2018 ; li NE[AMI DADS COUNTY P OIDUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Sbeat, Room 208 BOARD AND CODE ADNIUGSTRATION DMSION I Miami, Florida 33175 2474 T (786) 315-2590 F (786) 315-2599 NOTHCE ®Hi AOCHi PTANCI� (NOA) www.miamidade-Qav/eeonomv Gardner Asphalt Corporation 4161 W. 7s' Avenue Tampa, FL. 33605 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expination date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ �in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. IDESCLUPTI®No Gardner Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Cpntrol Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERBUNATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and 'removal moval of NOA. AIDVZ RTISZN7M.* The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. I HNSPECTI®No A copy of this entire NO, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site, at the request of the Building Official. This NOA renews and revises NOA# 17-04271.10 and consists of pages 1 through 5. The submitted documentation was reviewed by Alex Tigera. He: . , NOA:17-1221.15 • • o Expiration Date: 03/2=3 Approval Date: 03/29/19 Page 1 of 5 I i I ROOFING cCOwONENT APPRovAL ' Ca o : Roofing II Sub-Cateaorv: Underlayment Material: Asphalt I TRAuz NAmms OF PRODUCTS MANUFACTURED OR lLABELED By APPLICANT: ITest Product Product Dimensions Specification Description APOC Tuff -Felt 26 36" x 72' rolls ASTM D 226 Type II Asphalt Saturated Felt underlayment,, 2 Manufacturing square #30. Location #1, 2 ' United FGUR20 36" x 72' bolls ASTM D 226 Type H Asphalt Saturated Felt underlayment, 2 Manufactwing square #30. Location #1, 2 APOC Tuff Felt 46 36" x 144' rolls ASTM D 226 Type I Asphalt Saturated Felt underlayment, 4 Mam:facturing square #15. Location #1, 2 United IFGUR10 36" x 144' iolls ASTM D 226 Type I Asphalt Saturated Felt underlaymen44 Manufacturing I square #15. Location 41, 2 United FGUR70 18" x 72' rolls ASTM D 226 Type II Asphalt Saturated Felt underlayment, 1 Manufacturing I square #30. Location #1, 2 GatorSkin 42" x 285.8' lolls ASTM D 226 Type II Synthetic roof underlayment comprised Mam factoring I of layers of polyolefin film. Location 03 Weather -Armor CX-L 37.25" x 145' tolls ASTM D 226 Type H High strength hybrid underlayment Manufacturing comprised of two layers of polyolefin and Location #3 polyester synthetic fabric with a thin layer of modified bitumen between the two plies. Weather -Armor SB-1 36" x 65' 8" rolls ASTM D 1970 Glass fiber reinforced, polymer modified Manufacturing III asphalt, granulated self -adhered ' Location #4 underlayment. Gard -Lock 36" x 65' 8" rolls ASTM D 1970 Glass fiber reinforced, polymer modified Manufacturing asphalt, granulated self -adhered Location #4 underlayment. NOA:17-1221.15 Mu4raFnnnaEousra Expiration Date: 03/28/23 Approval Bate: 03A9118 Page 2 of 5 C Jt TRADE NAlmm OF PRODUCTS MANUFACTURED OR LABFLzD BY APPLICANT: Test ]Product Prodact Dimensions SreecificatioII IlDescriotion Weather -Armor E[T3 39" x 65' 8" rolls ASTM D 1970 60-mils thick (nominally), self -adhering Manufacturing membrane composed of elastic polymers, Location #4 bitumen, glass reinforcements and a cross laminated sheet surfacing. Weather -Armor IFT3 39" x 65' 8" rolls TAS 103 60-mils thick (nominally), self -adhering Manufacturing membrane composed of elastic polymers, Location #4 bitumen polyester and glass reinforcement. 0 MANUFACTURING LccAT on—. 1. Tacoma, WA. 2. Eutaw, AL. 3. Hangzhou, China. 4. Springville, AL. 3EVIDIZIgCE SUBMTTEIDo Test Aaencv Test Identifier Test Name/Revort Date PRI Construction Materials GGI-100-02-01 ASTM D 226 06/22/12 Technologies GGI-101-02-01 ASTM D 226 06/22/12 GGI-132-02-01 ASTM D 226 04/28/15 GGI-176-02-01 ASTM D 226 09/26/16 GGI-178-02-01 ASTM D 1970 10/25/16 GGI-194-02-01 ASTM D 1970 08/04/17 GGI-196-02-01 TAS 103 08/08/17' GGI-206.02-01 ASTM D 226 03/09/18 00I-207-02-01 ASTM D 226 03/09/18 APPYB®`f1m ASsmmmLIESo Deck Type 1: Wood, Non-insular.d DeckDescription: 19/32" or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened to deck. Anchor Sheet: One or more plies �,f APOC Tuff -Felt 26 United FGUR20 United FGUR70, GatorSkui, or Weather -Armor C-L with a minimum 4" headlap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6 inches o.c. minimum at all laps and three staggered rows fastened at 12 finches o.c. minimum in the field of the roll. Nails shall be driven flush and 90 degrees to the roof deck. Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry slate, metal roof applications, and as an anchor sheet in roof file applications. Must Comply with applicable Roofing Application Standards and Building Codes. 'MIAl9FgpDE:; u r NOA:17-1221.15 " o o Expiration Date: 03/28/23 Approval Date: 03/29/19 Page 3 of 5 Beek Type 1: Wood, Non insulated Deck Description: 19/32 " or greater plywood or wood plank System IE(2): Anchor sheet mechanically fastened to deck. Anchor Sheet: Minimum 2 plies or more of APOC Tuff -Felt 46, or United FGUR10 with a minimum 19" headlap and a 6" 1 end lap mechanically fastened to deck with approved nails and tin caps 6 inches o.c. minimum at all laps and three staggered rows fastened at 12 inches o.c. minimum in the field of the rill. Nails shall be driven flush and 90 degrees to the roof deck. Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry slate, metal roof applications, and as an anchor sheet in roof tile applications. Must Comply with applicable Roofing Application Standards and Building Codes. Deck Type 1: Wood, Non -insulated Deck Description: 19/32" or greater plywood or wood plank System E(3): Anchor sheet mechanically fastened to deck, membrane adhered. Anchor Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" headlap and a 6 end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge and in a grid pattern spaced 12" o.c. in the field of the roll. Membrane: One or more plies of Weather -Armor SB-1, Gard -Lock, or Weather -Armor HT3 self -adhering membrane adhered to the anchor sheet with a minimum 3" headlap and 6" end lap. Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry slate, and metal roof applications. Must Comply with applicable Roofing Application Standards and Building Codl s. Deck Type Il: Wood, Non -insulated Deck Description: 19/32" or greater plI�wood or wood plank System E(4): Anchor sheet mechanically fastened to deck, membrane adhered. Anchor Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" headlap and a 6 end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge and in a grid pattern spaced 12" o.c. in the field of the roll. Membrane: One or more plies of Weather -Armor FT3 self -adhering membrane adhered to the anchor sheet with a minimum 3'I'headlap and 6" end lap. Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry slate, metal roof, and mechanically fastened roof tile applications. Must Comply with applicable Roofing Application Standards and Building Codes. r wnne cbus , ' ; NOA:17-1221.15 Expiration Date: 03/28/23 Approval Date: 03/229/111 Page 4 of 5 J LABELING'. All membranes or packaging shall bear state and the following statement: "Mia Product Control Seal as shown below. ]BUILT DING PERMIT Application for building permit shall bi 1. This Notice of Acceptance. 2. Any other documents required the installation of this material. LII)WTATION r t or identifiable marking of the manufacturer's name or logo, city, County Product Control Approved" or the Miami -Dade County accompanied by copies of the following: the Building Official or applicable building code in order to properly evaluate 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building codi . 3. Weather -Armor SB-1, and Weather -Armor HT3 shall not be hot mopped; refer to manufacturer's published literature for product compatibility. 4. Gardner Underlayments listed herein are components used in roof assemblies. Roof assemblies are approved under specific assembly Notice of Acceptance. S. APOC-Tuff Felt 26, United FGUR20, APOC-Tuff Felt 46, United FGUR10, United FGUR70, GatorSkin, Weather Armor CX-L, and Weather -Armor SB-1 listed herein shall not be left exposed as a temporary roof for longer than 30 days of application 6. Weather -Armor HT3 and Weather -Armor FT3 listed herein shall not be left exposed as a temporary roof for longer than 180 days of application. 7. Gardner Underlayments listed herein may be used with any approved roof covering Notice of Acceptance listing Gardner Underlayments listed herein as a component part of an assembly in the Notice of Acceptance. If Gardner Underlayments l listed herein is not listed; a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. S. For fire classification of specific roof assemblies using Gardner Underlayments listed herein refer to a current Approved Roofing Materials Directory for fire ratings of this product. 9. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF TMS ACCEPTANCE w�wM NOA:17-1221.15 " Expiration Date: 03/20/23 Approval Date: 03/29/18 Page 5 of 5