HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTS• Miami -Dade County
Page 1 of 1
' SCANNED
Miami -Dade County Building B
0 ,, Dip
cip.. aC
Product Information for N.O.A. 17-1221.15 }a
Po0feei3 Vno(or(( .�ecLmTS
NOA 17-,221.15 t (library/productcontrollnoa117122115.pdf )
Superseded —BY
File Status
File'I pproved
File Classification
High velocity hurricane zone
Category
Roofing
Subcategory
Undel layments
Material
Asphalt
Applicant
Gardner Asphalt Cor oratior
March/28/2023
Expiration_Date
Impact —Rate
Unselelcted / Unknown
Maximum_Design_Pressure_Positive
0
Maximum —Design —Pressure —Negative
0
Description
Gardner Underlayments
Green —Sustainable —Attributes
NONE I
For a detailed description on the File Status, click "the NOA File Status Key. (/buitdino/pc-result key apn.asp )
Page Last Edited: Wed Jan 25, 2017 10:40:27 AM I
s.�
COUNTY
I
http://www.miamidade. gov/building/pc-result_app. asp?fldNOA=17-1221.15 &BasicS earch... 4/24/2018
-.Lv%LUL111-YCNiV VVLU1tj'
rup i OL i
Ifi'lami-Bade County Building
Product Control Search Results
QUERY PARAMETERS
File Ctessificatiom
i
High velocity hurricane zone
Applicant:
Gardner Asphalt Corporation
Category.
Roofing
Subcategory:
Underlayments
Material:
None
Impact Rate:
None
Maximum Design Pressure(*):
0.00
Nta dmum Design Pressure(-):
0.00
NOA
APPLICANT
CATMORY
SUBCATEGORY
MATEMAL
DESOMMOR
INPAOT
MDPr
MD0.
CLAeapEec
t7tPtnL'a
'17-1�1 16 rb
GartnerAeMeR
Roofing
Undedeymems
Asphalt
Gardner
UnseWed 1
0
0
High velocity
March
CORMOM ^
cam+:!! damn aAUW
Underlaymerds
Unknown
hurricane zone
282023
acc a7as.l008031
Rom
1
ru a uuwsaa owmpoon on the Elie stems, dick the N_OA Flle Statue i(ev I/bt no/x ac�it Ray anc oc 1
Page Last Mad: Wed Jan 28, 201710:40:27 AM
I
httP://www.miamidade.gov/buildinWpe.resu'tL-aPP-asP?fdNOA=&Classification—l%2CHi... 4/17/2018
;
li NE[AMI DADS COUNTY
P OIDUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Sbeat, Room 208
BOARD AND CODE ADNIUGSTRATION DMSION I Miami, Florida 33175 2474
T (786) 315-2590 F (786) 315-2599
NOTHCE ®Hi AOCHi PTANCI� (NOA) www.miamidade-Qav/eeonomv
Gardner Asphalt Corporation
4161 W. 7s' Avenue
Tampa, FL. 33605
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expination date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ �in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
IDESCLUPTI®No Gardner Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Cpntrol Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERBUNATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and 'removal
moval of NOA.
AIDVZ RTISZN7M.* The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety. I
HNSPECTI®No A copy of this entire NO, shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site, at the request of the Building Official.
This NOA renews and revises NOA# 17-04271.10 and consists of pages 1 through 5.
The submitted documentation was reviewed by Alex Tigera.
He: . , NOA:17-1221.15
• • o Expiration Date: 03/2=3
Approval Date: 03/29/19
Page 1 of 5
I
i
I
ROOFING cCOwONENT APPRovAL '
Ca o : Roofing II
Sub-Cateaorv: Underlayment
Material: Asphalt I
TRAuz NAmms OF PRODUCTS MANUFACTURED OR lLABELED By APPLICANT:
ITest Product
Product Dimensions Specification Description
APOC Tuff -Felt 26 36" x 72' rolls ASTM D 226 Type II Asphalt Saturated Felt underlayment,, 2
Manufacturing square #30.
Location #1, 2 '
United FGUR20 36" x 72' bolls ASTM D 226 Type H Asphalt Saturated Felt underlayment, 2
Manufactwing square #30.
Location #1, 2
APOC Tuff Felt 46 36" x 144' rolls ASTM D 226 Type I Asphalt Saturated Felt underlayment, 4
Mam:facturing square #15.
Location #1, 2
United IFGUR10 36" x 144' iolls ASTM D 226 Type I Asphalt Saturated Felt underlaymen44
Manufacturing I square #15.
Location 41, 2
United FGUR70 18" x 72' rolls ASTM D 226 Type II Asphalt Saturated Felt underlayment, 1
Manufacturing I square #30.
Location #1, 2
GatorSkin 42" x 285.8' lolls ASTM D 226 Type II Synthetic roof underlayment comprised
Mam factoring I of layers of polyolefin film.
Location 03
Weather -Armor CX-L 37.25" x 145' tolls ASTM D 226 Type H High strength hybrid underlayment
Manufacturing comprised of two layers of polyolefin and
Location #3 polyester synthetic fabric with a thin layer
of modified bitumen between the two
plies.
Weather -Armor SB-1 36" x 65' 8" rolls ASTM D 1970 Glass fiber reinforced, polymer modified
Manufacturing III asphalt, granulated self -adhered '
Location #4 underlayment.
Gard -Lock 36" x 65' 8" rolls ASTM D 1970 Glass fiber reinforced, polymer modified
Manufacturing asphalt, granulated self -adhered
Location #4 underlayment.
NOA:17-1221.15
Mu4raFnnnaEousra Expiration Date: 03/28/23
Approval Bate: 03A9118
Page 2 of 5
C Jt
TRADE NAlmm OF PRODUCTS MANUFACTURED OR LABFLzD BY APPLICANT:
Test ]Product
Prodact
Dimensions SreecificatioII IlDescriotion
Weather -Armor E[T3
39" x 65' 8" rolls ASTM D 1970 60-mils thick (nominally), self -adhering
Manufacturing
membrane composed of elastic polymers,
Location #4
bitumen, glass reinforcements and a cross
laminated sheet surfacing.
Weather -Armor IFT3
39" x 65' 8" rolls TAS 103 60-mils thick (nominally), self -adhering
Manufacturing
membrane composed of elastic polymers,
Location #4
bitumen polyester and glass
reinforcement.
0
MANUFACTURING LccAT on—.
1. Tacoma, WA.
2. Eutaw, AL.
3. Hangzhou, China.
4. Springville, AL.
3EVIDIZIgCE SUBMTTEIDo
Test Aaencv Test Identifier Test Name/Revort Date
PRI Construction Materials GGI-100-02-01 ASTM D 226 06/22/12
Technologies
GGI-101-02-01 ASTM D 226 06/22/12
GGI-132-02-01 ASTM D 226 04/28/15
GGI-176-02-01 ASTM D 226 09/26/16
GGI-178-02-01 ASTM D 1970 10/25/16
GGI-194-02-01 ASTM D 1970 08/04/17
GGI-196-02-01 TAS 103 08/08/17'
GGI-206.02-01 ASTM D 226 03/09/18
00I-207-02-01 ASTM D 226 03/09/18
APPYB®`f1m ASsmmmLIESo
Deck Type 1:
Wood, Non-insular.d
DeckDescription:
19/32" or greater plywood or wood plank
System E(1):
Anchor sheet mechanically fastened to deck.
Anchor Sheet:
One or more plies �,f APOC Tuff -Felt 26 United FGUR20 United FGUR70, GatorSkui, or
Weather -Armor C-L with a minimum 4" headlap and a 6" end lap mechanically fastened to
deck with approved nails and tin caps 6 inches o.c. minimum at all laps and three staggered
rows fastened at 12 finches o.c. minimum in the field of the roll. Nails shall be driven flush and
90 degrees to the roof deck.
Surfacing:
Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry
slate, metal roof applications, and as an anchor sheet in roof file applications. Must Comply with
applicable Roofing Application Standards and Building Codes.
'MIAl9FgpDE:; u r NOA:17-1221.15
" o o Expiration Date: 03/28/23
Approval Date: 03/29/19
Page 3 of 5
Beek Type 1: Wood, Non insulated
Deck Description: 19/32 " or greater plywood or wood plank
System IE(2): Anchor sheet mechanically fastened to deck.
Anchor Sheet: Minimum 2 plies or more of APOC Tuff -Felt 46, or United FGUR10 with a minimum 19"
headlap and a 6" 1 end lap mechanically fastened to deck with approved nails and tin caps 6
inches o.c. minimum at all laps and three staggered rows fastened at 12 inches o.c. minimum in
the field of the rill. Nails shall be driven flush and 90 degrees to the roof deck.
Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry
slate, metal roof applications, and as an anchor sheet in roof tile applications. Must Comply with
applicable Roofing Application Standards and Building Codes.
Deck Type 1: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(3): Anchor sheet mechanically fastened to deck, membrane adhered.
Anchor Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" headlap and a
6 end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap
edge and in a grid pattern spaced 12" o.c. in the field of the roll.
Membrane: One or more plies of Weather -Armor SB-1, Gard -Lock, or Weather -Armor HT3 self -adhering
membrane adhered to the anchor sheet with a minimum 3" headlap and 6" end lap.
Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry
slate, and metal roof applications. Must Comply with applicable Roofing Application Standards
and Building Codl s.
Deck Type Il: Wood, Non -insulated
Deck Description: 19/32" or greater plI�wood or wood plank
System E(4): Anchor sheet mechanically fastened to deck, membrane adhered.
Anchor Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" headlap and a
6 end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap
edge and in a grid pattern spaced 12" o.c. in the field of the roll.
Membrane: One or more plies of Weather -Armor FT3 self -adhering membrane adhered to the anchor sheet
with a minimum 3'I'headlap and 6" end lap.
Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry
slate, metal roof, and mechanically fastened roof tile applications. Must Comply with applicable
Roofing Application Standards and Building Codes.
r wnne cbus , ' ; NOA:17-1221.15
Expiration Date: 03/28/23
Approval Date: 03/229/111
Page 4 of 5
J
LABELING'.
All membranes or packaging shall bear
state and the following statement: "Mia
Product Control Seal as shown below.
]BUILT DING PERMIT
Application for building permit shall bi
1. This Notice of Acceptance.
2. Any other documents required
the installation of this material.
LII)WTATION
r t or identifiable marking of the manufacturer's name or logo, city,
County Product Control Approved" or the Miami -Dade County
accompanied by copies of the following:
the Building Official or applicable building code in order to properly evaluate
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance
with applicable building codi .
3. Weather -Armor SB-1, and Weather -Armor HT3 shall not be hot mopped; refer to manufacturer's published
literature for product compatibility.
4. Gardner Underlayments listed herein are components used in roof assemblies. Roof assemblies are approved
under specific assembly Notice of Acceptance.
S. APOC-Tuff Felt 26, United FGUR20, APOC-Tuff Felt 46, United FGUR10, United FGUR70, GatorSkin,
Weather Armor CX-L, and Weather -Armor SB-1 listed herein shall not be left exposed as a temporary roof
for longer than 30 days of application
6. Weather -Armor HT3 and Weather -Armor FT3 listed herein shall not be left exposed as a temporary roof for
longer than 180 days of application.
7. Gardner Underlayments listed herein may be used with any approved roof covering Notice of Acceptance
listing Gardner Underlayments listed herein as a component part of an assembly in the Notice of Acceptance.
If Gardner Underlayments l listed herein is not listed; a request may be made to the Authority Having
Jurisdiction (AHJ) or the Miami Dade County Product Control Department for approval provided that
appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire
testing results.
S. For fire classification of specific roof assemblies using Gardner Underlayments listed herein refer to a
current Approved Roofing Materials Directory for fire ratings of this product.
9. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61 G20-3 of the Florida Administrative Code.
END OF TMS ACCEPTANCE
w�wM NOA:17-1221.15
" Expiration Date: 03/20/23
Approval Date: 03/29/18
Page 5 of 5