Search Results
Query Date: Mon Jan 08 2018
Latitude: 27.5057
Longitude:-80,3069
ASCE 7-10 Windspeeds
(3-sec peak gust In mph*):
Risk Category I: 147
Risk Category II: 160
Risk Category III -IV: 171.
MRI** 10-Year: 87
MRI— 25-Year: 107
MRI** 50-Year: 119
MRI** 100-Year: 131
ASCE 7-05 Windspeed:
140 (3-sec peak gust in mph)
ASCE 7-93 Windspeed:
99 (fastest mile in mph)
*Mlles per hour
"Mean Recurrence Interval
Users should consuR with local building officials
to determine if there are community -specs is wind speed
requirements that govern.
n
= Print your results
NEBRASKA' .- �_- "_�CTRI.
_ „ILLINOI - Ot110 ; PENN I C 1"
ItedStates INDIANAi-MDrOPhAedelPhle 'I I RECEIVED
KANSAJ MISSOU 1 qr; VIRGINIA �' r
TKENTUCKY VINGINIA)'�
OP,LAHOMW * > TENNESSHEI tri NORTHk•, f
ARKANSAS t, �i ; CAgO,L*INA ) MAY 0 2 2098
JlA IS5 951PP1 SOUTH I
DaoIOS r, I t tt ,CAROL {
t ALABAh1A
TEXA5'�fft I j�GE0R01A '-.ST, lluCle County, P4rr
40UI IANAti "t1 _ ,
o
Houston 1 Y t
t 'FLOR I A�� Py
L'
Mexico ittQominFean
ePubllei
w�nnRtrel L,
I r 4h'u wtduros✓- - CenfrAwn. ^a „ ° r 1
WINDSPEED WEBSITE DISCLAIMER
While the information presented on this website is believed to be correct, ATC and its sponsors and contributors
assume no responsibility or liability for its accuracy. The material presented in the windspeed report should not
be used or relied upon for any specific application without competent examination and verification of its
accuracy, suitability and applicability, by engineers or other licensed professionals. ATC does not intend that the
use of this information replace the ;sound judgment of such competent professionals, having experience and
knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in
interpreting and applying the results of the windspeed report provided by this website. Users of the information
from this website assume all liability arising from such use. Use of the output of this website does not imply
approval by the governing building code bodies responsible for building code approval and interpretation for the
building site described by latitude/longitude location in the windspeed load report.
Sponsored by the ATC Endowment Fund • Applied Technolonv Council • 201 Redwood Shores Parkway, Suite 240 • Redwood City, California 94065 • (650) 595-1542
http://Windspeed.atcouncil.org/index.php?option=corn content&view=article&id=10&dec=... 1/8/2018
t
Google Earth
2017 Googld--
1,6 TN
Ilk,
Bonita Isle Dr Waters Edge Way � \1k
A"T
A:1
V.
'TAB'AW -nJ
vShore c 66% D r r
- I 'I �
3 i
TPA,
w .
CONTRACTOR: The Porch FacLLC
DESIGN CRITERIA:
1. The 6th Edition (2017) Florida Building Code, specifically Chapter 16 Structural Design,
Chapter 20 Aluminum, and Chapter 23 Wood.
2. AA ASM 35 and AA ADMI Specifications for Aluminum Structures, Part 1-A of the
Aluminum Design Manual prepared by The Aluminum Association. and the AAF Guide
to Aluminum Construction in High Wind Areas.
3. ASCE 7-10.
Loading Criteria
1. Live Load: 10 PSF per 6th Edition (2017) Florida Building Code, Appendix I Section
105.1
2. Dead Load: 2 PSF
3. Wind Load:
3.1. Building Occupancy Category, Section 1604.5 and Table 1604.5: Risk Category 1.
3.2. Basic Wind Speed, Figure 1609.3(3), State of Florida Debris Region & Basic Wind
Speed, Section 1609.3.1 and Table 1609.3.1 Equivalent Basic Wind Speed: VUL.r =
150 MPH, VASD =116 MPH
3.3. Exposure Category, Section 1609.4.3: Exposure C
3.4. Screen Enclosure Section 2002.4
4. Building Category for Aluminum Structures, Section 2002.6: Category Type 1- Screen
Fill: Non -Habitable, Unconditioned
Roof Type
1. Roof Type: EXISTING
2. Roof Material: EXISTING
Specifications
The following specifications are applicable to this project:
1. All work shall be in accordance with the 6th Edition (2017) Florida Building Code, and
any other applicable local codes and regulations.
2. Aluminum extrusions shall be 6005 TS Alloy. Due to quality control issues, no
manufacturer substitution is acceptable without the specific written, signed and sealed
authorization of Suncoast Aluminum Engineering, LLC.
3. Screen Material: Design based on 18/14 or 20/20 Better View. Any other material must be
approved.
4. Fasteners are required to be corrosion resistant, minimum SAE Grade 2 or better zinc
plated to ASTM B633, or coated stainless steel series "300", or uncoated stainless steel
series "400".
-4. -All-Self Mating-B-_eam Sections are to be stitched with either #14 screws 6" from ends and
24" center to center or # 12 screws 6" from ends and-12"-center to center.- - -----
5. All Porch Factory Beam Sections are to be stitched with #12 screws, 6" from ends and 12"
center to center.
6. Where concrete specifications are required, whether in the screen enclosure scope or not,
by one or more regulatory agency, the following specifications are applicable:
a. Concrete shall conform to ASTM C94 for the following components:
i. Portland Cement Type 1,- ASTM C 150
ii. Aggregates - Large Aggregate 3/4" max - ASTM C 33
iii. Air entraining +/- I % - ASTM C 260
iv.Water reducing agent - ASTM C 494
v. Clean Potable water
vi. Other admixtures not permitted
b. Metal accessories shall conform to:
i. Reinforcing Bars - ASTM A615, grade 60
ii. Welded wire fabric - ASTM A185
c. Concrete slump at discharge chute not less than 3" or more than 5". Water added
after batching is not permitted.
d. Prepare and place concrete per American Concrete Institute Manual of Standard
Practice, Parts 1, 2, and 3 including hot weather recommendations.
e. Moist cure or polyethylene curing permitted.
f. Prior to placing concrete, treat the entire subsurface area for termites in
compliance with the FBC.
g. Concrete shall be placed over a polyethylene vapor barrier.
h. All aluminum components embedded within concrete shall be coated with a
bituminous paint or epoxy.
7. All flashing and weatherproofing shall be provided by the contractor.
8. Door location shall be determined by contractor in the field.
9. Use of these plans acknowledges and accepts a limit of liability not to exceed design and
engineering fee.
WIND I-1---D AND EXPOSURE HAVE
BEEN 1. rRMINED USING THE ADVANCED
TECH"', )GY COUNCIL'S WEBSTTE
AND GOOGLE EARTH.
RECEIVED
MAY 0 2 2018
ST. Lucie County, Permitting
N
X
N
1X2
N
14'-0"
1X2
1X2
m
X LO
04
X
n
in
A-2
A-2
2X3
2X3
1X2
1X2
1�
I
00 o
I
CV
A-2
7'-0" 7'-0"
0
I
00
�I�- 8'-7-
����111111111�//
O O'.
=Q:JJJ n r o:Z-
' Z -�• 000
1co
a N
CO
1
IIIIII-�����
PROFESSIONAL S`EAL
La LJ.I
O Q Li
W r p�
LL Z w
�o
tY Qm Wm
LU a� .2
LU z z
W W
Q7 C) Q a
Z =7 U ZOU
7
W Hu' l7CLL
0
o Z U c
.,
J
F- Z�
t/f tm§§
Q W W S 9 T
O L LJ W .Nrf in
Z
Z (� R4r.
5 Z "
m
in W � . I-- �-*
Q W Lu
W cc
W W=av
0 toU-)
(Z < n U- LL
TP
DATE DRAWN
01/11/18
REVISION
SHEET NO:
Q�
U
W
N
z
U
c
x
C
C
O
LL
A-1
ALUMINUM MEMBERS DIMEA MKS
HOLLOW SECTIONS
2 x 2: 2" x 2" x 0.046"
2x3:2"x3"x0.050"
2x4: 2"x4"x0.050"
2x5:2"x5"x0.050"
OPEN BACK SECTIONS
1x2: 1"x2"x0.040"
1x3: 1"x3"x0.045"
SNAP SECTIONS
2 x 2 Snap: 2" x 2" x 0.045"
2 x 3 Snap: 2" x 3" x 0.050"
2 x 4 Snap: 2" x 4" x 0.045"
SELF MATING (SMB)
2x4SMB: 2" x 4" x 0.044" x 0. 100"
2 x 5 SMB: 2" x 5" x 0.050" x 0.100"
2x6SUB: 2" x 6" x 0.050" x 0. 120'
2x7SMB: 2" x 7" x 0.057" x 0. 120'
2 x 8 SMB: 2" x 8" x 0.072" x 0.124"
2 x 9 SMB: 2" x 9" x 0.072" x 0.124"
2 x 10 SMB: 2" x 10" x 0.092" x 0.398"
MINIMUM FASTENER EDGE DISTANCE: 1/2"
MINIMUM FASTENER SPACING: 3/4"
CONCRETE SCREW ANCHOR:
SIMPSON TITEN HD OR EQUIVALENT
SHEET METAL SCREWS (SMS):
ITW / BUILDEX OR EQUIVALENT
PFB: PORCH FACTORY BEAM
1/8" x 2" x 2' EXTRUDED
ANGLE 5052 H-32 ALLOY EA
SIDE W/ (4) #14 x 3/4"SMS
INTO UPRIGHT_
PAVERS--,. • •
BONDEDTO
11/4•MIN ON..
JCONC
CHOEMBED.211P MIANCHOR5d MIN EDGE DISTANCE FROM
SLAB/ FOOTING °' ; EXTERIOR OF COLUMN TO
SEE PLAN •, s ° ` . OUTSIDE EDGE OF SLAB
SIDE VIEW
(1) 3/8" DIA. CONCRETE
SCREW ANCHORS
(2 1/4" CONC. EMBED)
1" x 2" BASE PLATE
BRICK PAVERS ANCHORED TO CONC W/ 1/4"
CONCRETE SCREW ANCHOR
(MIN. 1 1/4" CONC. EMBED)
6" MAX EACH SIDE OF POST
• .r. . •,� ; AND 24" O.C. MAX
SLAB / FOOTING
SEE PLAN < 8 s
FRONT VIEW
B UPRIGHT TO CONCRETE W/PAVERS DETAIL
A-2 SCALE: NTS
CONC. HEADER:
1/4" x 3" CONCRETE
SCREW ANCHOR @ 24" O.C.
WOOD HEADER:
#10 x 3" WOOD SCREWS
@ 12" O.C.
V x 2" HOLLOW
WOOD:
#10 x 3" WOOD SCREWS
@ 12" O.C.
CONC:
1/4" DIA x 3" CONCRETE
SCREW ANCHOR @ 24" O.C.
1" x 2" HOLLOW
EXISTING
B-T1X2 TO HEADER DETAIL
A-2 SCALE: NTS
Q:•zud
Z '
a'•
0. z
co
PROFE
SIONAL SEAL
W
ui
Ld c
O
n
d
Lu
z
�� a
LL
zc
egg i
W
O
e
Lr
Q W
m
W W z
J m LL
Lu
a�
i
Lu
z
j3 z 2
Z
h
�z
Jy ?
Qz
Z
Lu
x
HLL
O:
OCLL a
�i
I
Z • ei
U
. am
.y
Q Z C$
I= t -. - -
S
Q LJJ W , T a
Lu
as
z
O
Z
U �QNN
= I
Z l'7 a3c�
Z ��
o
o
VI Lu
WOOD HEADER:
(1) 3/8" x T LAG SCREW INTO HEADER
WOOD:
CONCRETE HEADER:
#10 x 3" WOOD SCREWS,
I 6"
W
(1) 3/8"DIA. x 3" CONCRETE SCREW
I
& @ 12" O.C.
It
ANCHOR INTO HEADER
CONC:FROMGIRT
LN
14' DIA. x 3" CONCRETE
0
SCREWANCHOR, G'
W
21/2" x 1/8" x (GIRT OR PURLIN
FROM GIRT & @ 24" O.C.
0 0
WIDTH + 1/2" x BEAM DEPTH
I
INTO
Q W LLJ
U
EXISTING
OR UPRIGHT DEPTH -1/2")
SCREW BO S
It
HEADER
I
ALUM BACKING PLATEri
(
=
6063-T6ALUMNINUM
LLI W a It
--
m1n�M
a ¢M°LL
1"x2"HOLLOW
1"x2" W/#10x2"SMS-9'
�Z'x
DRAWN BY
SECTION MAX EACH SIDE OF POST €
€ (4)1110 x 1 1/2" SMS INTO
#
I
HOLLOW
AND 24" O.C. MAX
CHAIR RAIL MEMBER
' - SCREW BOSSES
I SECTION GIRT
TP
2" x 2" x 0.12T ALUM ANGLE W/
j (
I
DATE DRAWN
(4) #14 x 3/4" SMS INTO UPRIGHT
I g
i
1" x 2"
01/11/18
z-r
REVISION
UPRIGHT
UPRIGHT/BEAM
Q -
©
C
�!-i 1X2 TO HOST STRUCTURE DETAIL
SHEET NO:
B-2 POST TO HEADER
DETAIL
PURLIN OR
A-2
GIRT TO BEAM OR POST DETAIL
SCALE: NTS
/�
A-2 SCALE: NTS
A-2 SCALE: NTS
A-2
z
LL
C
O:
n
E
a
LL
R
tC-
C
z
<C 4U -4
co cs
I Z
0
0:
CL Ui
4z-,e : 0--
GRADE
co
8 8
L
C
PRO FEll
SEAL
i
(1) #5 CONT ON
CHAIRS
Eq
8" X 8" RIBBON
0
FOOTING
Cc
La Ld
0
LLJ
c"
�a
NOTES FOR ALL FOUNDATION TYPES:
1. THE
ILL.
w 4
z W Lu 0
LL
9
FOUNDATIONS SHOWN ARE BASED ON A MIN SOIL BEARING
0
w
L
PRESSURE OF 1,500 PSF.
a LLJ
z
2. THE SLABIFOUNDATION SHALL BE CLEARED OF DEBRIS, ROOTS AND
LLJ
go -j ca
LL
COMPACTED PRIOR TO PLACEMENT OF CONC.
Lu
3. CONCRETE SHALL BE PER SPECIFICATIONS ON SHEET A-1.
z
z z
w
4. FIBERMESH MAY BE USED IN LIEU FOR WELDED WIRE MESH.
z Q z
5. VAPOR BARRIER NEED NOT BE INSTALLED FOR EXTERIOR
w w
0 u z u
NON -HABITABLE CONCRETE FLAT WORK
z
== om
I-
Lu
P
E
4
cr
ONTINUOUS FOOTING
z
LL
c
2
c
SUA-L-E-N-TT-
rr
CL
Z
z
ta '.- § 1 6
0 Lu z
u z K r
LL
1/8"x 2"x 2" EXTRUDED (4) #14x3/4"SMS
INTO DJ
Z (D.
H
ANGLE 5052 H-32 ALLOY
Z
(A Lu O
BRICK PAVERS
BONDED TO
c-
CONCRETE
LL
T4
• 21/4"MIN
SLAB / FOOTING CONC
LU
LL
SEE PLAN ANCHOR
-
LA >
.4 EMBEDMENT
LLI w
c
m
IL
SIDE VIEW
Lu
9
11
Ir
M
Co Lu
cc
LU
0
!!J
2"x2"DJ
(4) #14 x 314"SMS
Lu U.1 = a11,
U) 0)
F-
INTO DJ
(1) 3/8' DIA. CONCRETE
I= co o -i
SCREW ANCHORS
< Cr) LL LL
(2 1/4- CONC. EMBED)
DRAWN BY
1" x 2- BASE PLATE
ANCHORED TO CONC W/ 1/4"
TP
CONCRETE SCREW ANCHOR
DATE DRAWN
(MIN. I 1/4" EMBED)
LA
6- MAX EACH SIDE OF POST
01/11/18
AND 24"O.C. MAX A
REVISION
'A
FRONT VIEW
SHEETNO:
rDJ 1 DOOR JAMB TO CONCRETE W/ PAVERS DETAIL
�-3 SCALE: NITS
A 3
1