Loading...
HomeMy WebLinkAboutEVALUATION REPORTA RECEIVED SCANNED MAY 0 12018 BY de St Lucie County � EVALUATION REPORT Manufacturer: Qualitjr Assurance: SCOPE Category: Subcategory: Code Sections: Properties: PRODUCT DESCRIPTION TAMKO® ASTM Slate �wSurfaced Roll Roofing TAMKOO ASTM Tile nderlaymenf TAMKO® Master 41 4mooth �77 TAMKOO Moisture Guard® ` AMKO® No.15 ASTM M. sphalt Saturated L, rganic Felt TAMKO® No.15 UL t t•� :Asphalt Saturated Organic Felt TAMKO9 No. 30 ASTM Asphalt Saturated Organic Felt me TAMKOO No. 30 UL w Asphalt Saturated Organic Felt cta ` oc TAMKO® TW Metal and e Tile Underlayment ._ TAMKO®TW Underlayment R TAMKO BUILDING PP P.O. Box 1404 Joplin, MO 64802 (417)624-6644 htto:/Iwww.tamko.co_m UL LLC (QUA9625) Roofing . Underlayments 1507.1.1 Physical properties Certificate of Authorization No. 29824 17520 Edinburgh Drive Tampa, FL 33647 (813) 480-3421 FLORIDA BUILDING CODE, C EDITION (2017) wied Getabe 19, 2017 ST. LUCIE CCAJN Y. BUILDING DIVISION FOR COMPL➢t' CE REVIEW^/EL, PY _ DATE / fOR : P' r ER IT NO INSPE011 'N WILL 09 MADE ASTM D 6380, Class M. Type II underlayment constructed with asphalt and coated on both sides with asphalt and sur ASTM D 6380, Class M, Type II underlayment constructed with asphalt then coated on both sides with asphalt and su ST. LUCIE COAJl#T1r j r..r'11•,� i/� Jam, Io4Jil MI ti�'}��V'1 ��1�%/{I-I:-:r-/,'�irJl i�, ASTM D 6380, Class S, Type IV undedayment constructed from an organic felt saturated with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For use in non-HVHZ_only. Self -adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane with a mineral surfacing and a removable release film on the adhesive side and removable selvedge release tape. ASTM D 226, Type I undedayment constructed from a non -perforated organic felt that is saturated with asphalt ASTM D 226. Type I undedayment constructed from a non -perforated organic felt that is saturated with asphalt ASTM D 226, Type 11 undedayment constructed from a non -perforated organic felt that is saturated with asphalt ASTM D 226, Type 11 undedayment constructed from a non -perforated organic felt that is saturated with asphalt Self -adhered, flexible, ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane with a polymerfilrri on the surface and a removable release film on the adhesive side. Self -adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a polymer film on the surface and a removable release film on the adhesive side. TBP14ODl A FL12328-R8 Page 1 of 4 This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changesor quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ` fw� TAMKO BUILDING PRODCUTS, INC. CREEK � TAMKO Underlayments TECHNICAL SERVICES, LLC TAMKO® TAM -FELT Alternate to ASTM D 226, Type 1 and Type II underiayment constructed from a non - perforated organic felt that is saturated with asphalt. APPLIcATiON METHOD requirements below. Deck substrates shall be clean, dry, and free from any irregularities and debris. - All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting joints. The minimum application temperature shall bey 50"F except as follows: a) The minimum application temperature of TAMKOS TW Metal and Tile Underiayment and TAMKOS TW Underlayment shall be 40°F. b) The minimum application temperature of TAMKOS Moisture Guard® shall be 350F. The minimum roof slope shall be in accordance with FBC requirements except as follows: a) The minimum slope of TAMKOOASTM Slate Surfaced Roil Roofing shall be 2:12. Underlayments shall be exposed in accordance with the manufacturer's recommendations, but in no case shall exposure exceed 30 days. Exception: TAMKOS TW Metal and Tile Underlayment may be exposed for a maximum 90 days. Self -adhering underlayments may be adhered; to primed or unprimed plywood substrates in the non-WHZ. All roof coverings shall be mechanically fastened through the undedayment to the roof deck. Allowable Roof Coverines, Metal Roof Mineral Wood - Asphalt::. Panelsand -Surraced'Rall -Shingle-sand Slate Clayand Undeila ent 'Shin lea . Shingles.. -Rootin - -.Shakes. : Shin les:. concrete Tile TAMKOS ASTM Slate Y' N N N N Y Surfaced Roll Roofing TAMKOS ASTM Tile N N N N N Y Underlayment TAMKOS Master Smooth Y' N N N N N TAMKOS Moisture Guard® Y N N N N N TAMKOS No.15 ASTM Asphalt Saturated Organic Y Y Y YZ N N Felt TAMKOS No.15 UL Asphalt Y Y Y Yz Y N Saturated Organic Felt TAMKO9 No. 30 ASTM Asphalt Saturated Organic Y Y Y Y Y Y Felt TAMKOS No. 30 UL Asphalt Y j Y Y N Y N Saturated Organic Felt TAMKOS TW Metal and Tile Y Y N N N Y Underlayment TAMKOS TW Underlayment Y i Y N N N N TAMKOSTAM-FELT Y N N N N N Notes: 1) open valley applications per 1507.2.9z 2) Wood shingles only TBP14001A Technical Services, LLC of any product changes This evaluation report does not express nor imp] specifically addressed herein. FL12328-R8 2 of 4 assurance changes throughout the duration for which this report is valid. r, installation, recommended use, or other product attributes that are not TAMKO BUILDING PRODCUTS, INC. CREEKTAMKO Underlayments TECHNICAL SERVICES, LLC LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) Wind uplift resistance in not within scope of this evaluation. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) Contact the manufacturer when installing at temperatures below the minimum application temperature. 5) Unless otherwise stated, the minimum roof slope shall be in accordance with FBC requirements. 6) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped in successive courses installed up the deck in a manner that effectively sheds water from the deck. End laps shall be staggered between courses in accordance with the manufacturer's application instructions. 7) The underlayment may be used as described in other current FBC product approval documents. 8) The underlayment shall not be installed over existing roof coverings. 9) Contact the manufacturer regarding specific exposure limits for each underlayment 10) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST6049) TAP-192-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) TAP-193-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) TAP-214-02-01 ASTM D 4869 2016 PRI Construction Materials Technologies (TST6049) TAP-215-02-01 ASTM D 226 2009 PRI Construction Materials Technologies (TST6049) TAP-216-02-03 ASTM D 6380 2003(2013) PRI Construction Materials Technologies (TST6049) TAP 217-02-01REV ASTM D 6380 2003(2013) PRI Construction Materials Technologies (TST6049) TAP-218-02-01 ASTM D 226 2009 PRI Construction Materials Technologies (TST6049) TAP 219-02-01 ASTM D 226 2009 PRI Construction Materials Technologies (TST6049) TAP 220-02-01 ASTM D 6380 2003(2013) PRI Construction Materials Technologies (TST6049) TAP 222-02-01 ASTM D 4869 2016 PRI Construction Materials Technologies (TST6049) TAP 245-02-01 TAS 103 1995 ASTM D 4798 2011 PRI Construction Materials Technologies (TST6049) TAP-311-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) TAP-319-02-01.1 ACC 188 2012 PRI Construction Materials Technologies (TST6049) TAP-387-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) TAP-388-02-01 ASTM D 1970 2015a UL LLC (TST9628) 13CA12269 ASTM D 226 2009 TBP14001.4 FL12328-R8 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quardy assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. TAMKO BUILDING PRODCUTS, INC. CREEKTAMKO Underlayments TECHNICAL SERviCEs, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6v' Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. • No 74021---12:15:58 04'00' 13 STATE OF :41 ;6� !�O'�••.-< P: N Zachary R. Priest, P.E. .R C? .` Florida Registration No. 74021 010�0(yp; �� s�Organization No. ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT TBP14001.4 FL72328-R8 Page 4 of 4 This evaluation report is provided for State of Floridaproduct approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.