Loading...
HomeMy WebLinkAboutPRODUCT APPROVALBCIS Home j Log In { User Registration I Hot Topics Hoiicb r Product Approval 1 USER: Public User Product Approval Menu > Product or Application Search > a Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative W CC Address/Phone/Email O� } 9— O I= O W Co `7(n Z) j QA9 ci a Z —I .: Quality Assurance Representative Va V o Address/Phone/Email 1 wo k ZCLz Q; I LI Q V ® Q M-9 O (bl . (q F— " u,' Ci Category —I -: cc m r„ Subcategory I7 DA Compliance Method LC •: Page 1 of 4 Submit Surcharge $tais.8 I Publications ; FBC Staff I BCIS Site Map I Links i Search I RECEIVE® MAY 01 2018 _LS1 > Appli tion Detail ST. Lucie County, Permitting FL17022-R7 Revision 2017 Approved 08/18/2017v. date reapply 08/21/17 Extreme Metal Fabricators, LLC 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 Flvalidation@yahoo.com Richard McKuhen Flvalidation@yahoo.com Richard McKuhen 2160 SW Poma Drive Palm City, FL 34990 (772)872-8034 rchard@emfab.net f�ONGEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILf 7Y OF THE Roofing CONTRACTOR OF RECORD Metal Roofing Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed LOCKE BOWDEN the Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications, Inc. a� LLA Quality Assurance Contract Expiration Date 04/22/2024 CI Validated By Zachary R. Priest, P.E. '7 Validation Checklist - Hardcopy Received CS �) t`s 1,: =S Certificate of Independence FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.odf ui S. Referenced Standard and Year (of Standard) Standard TAS 125 2003 UL 1897 2012 UL 580 2006 =' a j !:.^ Equivalence of Product Standards s Certified By ' Sections from the Code i +; https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQ... ' 2/16/2018 Florida Building Code Online Page 2 of 4 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method 1 Option D 08/18/2017 08/25/2017 08/28/2017 10/10/2017 FL # Model, Number or, Name Description 17022.1 1 - "5V Crimp" (R6)I 26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel mechanically attached to 15/32" plywood or Wood Deck with fasteners Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation Instructions. 17022.2 12 - "5V Crimp" (R6) Limits of Use i Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions.Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.3 13 - "1.5" Mechanical Seam" (R5) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.4 14 - "1.5" Mechanical Seam" (R5) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for condition's and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.5 I 15 - "1 in. Nail Strip" (R5) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with Installation Instructions FL17022 R7 II FL 17022.1 5 V CRIMP ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports . FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.Ddf Created by Independent Third Party: Yes 0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel, mechanically attached to 15/32" plywood or Wood Deck with exposed fasteners Installation Instructions FL17022 R7 11 FL 17022.2 5 V CRIMP 0.032 ALUM ssr.Ddf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssr.Ddf Created by Independent Third Party: Yes 1.5" rib height, 16" wide, 24 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with clips and fasteners. Installation Instructions FL17022 R7 fI FL 17022.3 1.5 MECHANICAL seam 24oa ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022_ R7 AE FL 17022.3 1.5 MECHANICAL seam 24ga ssr.odf Created by Independent Third Party: Yes 1.5" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to 15/32" plywood or Wood Deck with clips and fasteners. Installation Instructions FL17022 R7 II FL 17022.4 MECHANCIAL SEAM ALUMINUM ssr.Ddf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM ALUMINUM ssr.Ddf Created by Independent Third Party: Yes 1" rib height, 16" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Installation Instructions FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.Ddf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssr.Ddf Created by Independent Third Party: Yes https://www.floridabuilding. org/prlpr_app_dtl.asp,x?param=wGEVXQwtDgv2aBQpHpQQ... 2/16/2018 Florida Building Code Online Page 3 of 4 the installation method listed in this report and applicable code sections of FBC. Refer to manufacturers installation instructions. 17022.6 16 - "1 in. Nail Strip" (R5) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. I 17022.7 17 - "1.5 in. Nail Strip" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's'installation instructions. 17022.8 18 - "EMAX Rib" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design.Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of-FBC. Refer to manufacturer's installation instructions. 17022.9 19 - " PBR MAX" (R5) ' Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the Installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 1" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to attached to 15/32" plywood or Wood Deck with fasteners, Installation Instructions FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.032 ALUM ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032 ALUM ssr.odf Created by Independent Third Party: Yes 1.5" rib height, 19" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Installation Instructions FL17022 R7 II FL. 17022.7 1.5 Nail Strip 26GA ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.Ddf Created by Independent Third Party: Yes 29 gauge steel, lapped roof panel mechanically attached 15/32" plywood or wood deck with exposed fasteners. Installation Instructions FL17022 R7 11 FL 177022.8 EMAX Rib ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 177022.8 EMAX Rib ssr,pdf Created by Independent Third Party: Yes 26 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Installation Instructions FL17022 R7 II FL 17022.9 PBR RIB ssr odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.9 PBR RIB ssr,odf Created by Independent Third Party: Yes Back Nett Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an ANEEO employer. Copvriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012i licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: 7�1 RR E Credit Card Safe https://www.floridabuilding. org/prlpr_app_dtl.aspx?param=wGF,VXQwtDgv2aBQpHpQQ... 2/16/2018 Palm City, FL 34990 Compliant with Florida Building Code 2017 (61h ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Product: 1" Nailstrip 26GA Steel Roof Panel FBC Sec.1507.4.2 Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood Deck w/ 0.42 specific gravity with 16" Coverage (Max.) Rib Height 1" 1 Corrosion Resistant Compliant: FBC Sec.1507.4.3 Fastener 1: #10 x 1" (min.) Pancake Head Wdod Screw to penetrate 3/16" (min.) thru bottom of support. i Adhesive/Sealant : Bostik 915T" Chem -Chalk one component, polyurethane adhesive with 3/16" continuous bead application along base of male rib vertical flange at each panel seam. Underlayment: To be compliant with FBC Sec.1507.1.1 i Slope: Shall be in compliance with FBC Sec. 15'07. Install Details: Table A Allowable Loads METHOD 1 METHOD 2 DESIGN PRESSURE* �-86 PSF Main field -97.25 PSF Perimeter (..FASTENER SPACING _ 6" O.C. _ 6" O.C. SEAM ADHESIVE Not required 3/16" continuous bead Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527 �j UL 580-06 & UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen #1 & #2 ,EQUIVALENCY. ULI897704 fs equivalent to Test Standard UL1897-12. Desi n Pressure.. mar ,m of safety Certificate of Independence: Locke Bowden, P.E. does not have, not will acquire a financial iWf*41t4r#iWy, company manufacturing or distributing products under this evaluation. `�. D. BQ, <o Locke Bowden, P.E. is not owned, operated, or control).. �r�Y mpy titan Curer, or distributing products under this �, �• ,�� i report. seal 11 � • KATE OF "'� �•° '�11OR1UY' °'ate' - °s�c�,•p. .•� �� o. Limitations: 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6t' ed.. 2. Minimum slope to be compliant with Florida Building Code 2017 6t' ed., and per with Manufacturers installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities wludsdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6"' ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. i 7. This report does not imply warranty, installation, recommended product use outside of this report. FL 17022.5 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details 16" —F— �_ � 3/4_� Panel Profile 16" o. c. fA Deck: -15/32" or greater Plywood, or - Wood plank Integral Snap Lock For METHOD 2: Apply 3116" Bead Bostik 915111" Sealant Continuous Along Male Rib Vertical Flange �.\ Fastener #10 x 1" Min. per Table "A" Pancake Head Wood Screw (Typical Fastening Pattern Across Width) FL 17022.5 1.0 Nail Strip (266A Steel),16" Wide Roof Panel - Details 1" Nail Strip Roof Panel Deck: -15/32" or greater Plywood, or - Wood plank Fastener ----\ #10 x.1" Min. per Table "A" Pancake Head VVood Screw i Isometric View i Seam Adhesive Application: For Method 2 Apply 3/16" Bead Bostik 915Tm Sealant Continuous Along Male Rib Vertical Flange (Refer to Table "A")