HomeMy WebLinkAboutPRODUCT APPROVALBCIS Home j Log In { User Registration I Hot Topics
Hoiicb
r Product Approval
1 USER: Public User
Product Approval Menu > Product or Application Search >
a Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
W
CC
Address/Phone/Email
O�
}
9— O
I= O W
Co
`7(n
Z) j QA9 ci
a Z —I .:
Quality Assurance Representative
Va
V
o
Address/Phone/Email
1 wo k
ZCLz
Q; I LI Q
V ®
Q M-9 O
(bl
.
(q F— "
u,' Ci
Category
—I -: cc m
r„
Subcategory
I7
DA
Compliance Method
LC •:
Page 1 of 4
Submit Surcharge $tais.8 I Publications ; FBC Staff I BCIS Site Map I Links i Search
I RECEIVE®
MAY 01 2018
_LS1 > Appli tion Detail
ST. Lucie County, Permitting
FL17022-R7
Revision
2017
Approved
08/18/2017v. date reapply 08/21/17
Extreme Metal Fabricators, LLC
2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
Flvalidation@yahoo.com
Richard McKuhen
Flvalidation@yahoo.com
Richard McKuhen
2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
rchard@emfab.net
f�ONGEALED FASTENERS OR ATTACHMENTS
ARE THE RESPONSIBILf 7Y OF THE
Roofing CONTRACTOR OF RECORD
Metal Roofing
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed LOCKE BOWDEN
the Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
a� LLA Quality Assurance Contract Expiration Date 04/22/2024
CI Validated By Zachary R. Priest, P.E.
'7 Validation Checklist - Hardcopy Received
CS �)
t`s 1,: =S Certificate of Independence FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.odf
ui S.
Referenced Standard and Year (of Standard) Standard
TAS 125 2003
UL 1897 2012
UL 580 2006
=' a j !:.^
Equivalence of Product Standards
s Certified By
' Sections from the Code i +;
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQ... ' 2/16/2018
Florida Building Code Online
Page 2 of 4
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Method 1 Option D
08/18/2017
08/25/2017
08/28/2017
10/10/2017
FL # Model, Number or, Name Description
17022.1 1 - "5V Crimp" (R6)I 26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel
mechanically attached to 15/32" plywood or Wood Deck with
fasteners
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions. Install the
assembly in compliance with the installation method listed in
this report and applicable code sections of FBC. Refer to
manufacturer's installation Instructions.
17022.2 12 - "5V Crimp" (R6)
Limits of Use i
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions.Install the
assembly in compliance with the installation method listed in
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022.3 13 - "1.5" Mechanical Seam" (R5)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions.
17022.4 14 - "1.5" Mechanical Seam" (R5)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for condition's and
limitations of use. Install the assembly in compliance with
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions.
17022.5 I 15 - "1 in. Nail Strip" (R5)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with
Installation Instructions
FL17022 R7 II FL 17022.1 5 V CRIMP ssr.odf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports .
FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.Ddf
Created by Independent Third Party: Yes
0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof
panel, mechanically attached to 15/32" plywood or Wood
Deck with exposed fasteners
Installation Instructions
FL17022 R7 11 FL 17022.2 5 V CRIMP 0.032 ALUM ssr.Ddf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032
ALUM ssr.Ddf
Created by Independent Third Party: Yes
1.5" rib height, 16" wide, 24 gauge steel, standing seam
roof panel mechanically attached to 15/32" plywood or wood
deck with clips and fasteners.
Installation Instructions
FL17022 R7 fI FL 17022.3 1.5 MECHANICAL
seam 24oa ssr.odf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022_ R7 AE FL 17022.3 1.5 MECHANICAL
seam 24ga ssr.odf
Created by Independent Third Party: Yes
1.5" rib height, 16" wide, 0.032" aluminum, standing seam
roof panel mechanically attached to 15/32" plywood or Wood
Deck with clips and fasteners.
Installation Instructions
FL17022 R7 II FL 17022.4 MECHANCIAL SEAM
ALUMINUM ssr.Ddf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM
ALUMINUM ssr.Ddf
Created by Independent Third Party: Yes
1" rib height, 16" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood
deck with fasteners.
Installation Instructions
FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.Ddf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssr.Ddf
Created by Independent Third Party: Yes
https://www.floridabuilding. org/prlpr_app_dtl.asp,x?param=wGEVXQwtDgv2aBQpHpQQ... 2/16/2018
Florida Building Code Online
Page 3 of 4
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturers installation
instructions.
17022.6 16 - "1 in. Nail Strip" (R5)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions. I
17022.7 17 - "1.5 in. Nail Strip" (115)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's'installation
instructions.
17022.8 18 - "EMAX Rib" (115)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design.Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with
the installation method listed in this report and applicable
code sections of-FBC. Refer to manufacturer's installation
instructions.
17022.9 19 - " PBR MAX" (R5) '
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with
the Installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions.
1" rib height, 16" wide, 0.032" aluminum, standing seam
roof panel mechanically attached to attached to 15/32"
plywood or Wood Deck with fasteners,
Installation Instructions
FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.032
ALUM ssr.odf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032
ALUM ssr.odf
Created by Independent Third Party: Yes
1.5" rib height, 19" wide, 26 gauge steel, standing seam
roof panel mechanically attached to 15/32" plywood or wood
deck with fasteners.
Installation Instructions
FL17022 R7 II FL. 17022.7 1.5 Nail Strip 26GA ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.Ddf
Created by Independent Third Party: Yes
29 gauge steel, lapped roof panel mechanically attached
15/32" plywood or wood deck with exposed fasteners.
Installation Instructions
FL17022 R7 11 FL 177022.8 EMAX Rib ssr.odf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 177022.8 EMAX Rib ssr,pdf
Created by Independent Third Party: Yes
26 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Installation Instructions
FL17022 R7 II FL 17022.9 PBR RIB ssr odf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.9 PBR RIB ssr,odf
Created by Independent Third Party: Yes
Back Nett
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an ANEEO employer. Copvriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send
electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012i licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under
Chapter 455, F.S., please click here .
Product Approval Accepts:
7�1 RR E
Credit Card
Safe
https://www.floridabuilding. org/prlpr_app_dtl.aspx?param=wGF,VXQwtDgv2aBQpHpQQ... 2/16/2018
Palm City, FL 34990
Compliant with Florida Building Code 2017 (61h ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Product: 1" Nailstrip 26GA Steel Roof Panel FBC Sec.1507.4.2
Yield strength: 50 ksi min.; Attached to min.15/32" plywood or
Wood Deck w/ 0.42 specific gravity with 16" Coverage (Max.)
Rib Height 1" 1
Corrosion Resistant Compliant: FBC Sec.1507.4.3
Fastener 1: #10 x 1" (min.) Pancake Head Wdod Screw to penetrate 3/16" (min.) thru
bottom of support. i
Adhesive/Sealant : Bostik 915T" Chem -Chalk one component, polyurethane adhesive with
3/16" continuous bead application along base of male rib vertical flange at each panel
seam.
Underlayment: To be compliant with FBC Sec.1507.1.1
i
Slope: Shall be in compliance with FBC Sec. 15'07.
Install Details: Table A Allowable Loads
METHOD 1
METHOD 2
DESIGN PRESSURE*
�-86 PSF Main field
-97.25 PSF Perimeter
(..FASTENER SPACING _
6" O.C.
_ 6" O.C.
SEAM ADHESIVE
Not required
3/16" continuous bead
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527
�j UL 580-06 & UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen #1 & #2
,EQUIVALENCY. ULI897704 fs equivalent to Test Standard UL1897-12. Desi n Pressure.. mar ,m of safety
Certificate of Independence:
Locke Bowden, P.E. does not have, not will acquire a financial iWf*41t4r#iWy, company manufacturing or distributing products
under this evaluation. `�. D. BQ, <o
Locke Bowden, P.E. is not owned, operated, or control).. �r�Y mpy titan Curer, or distributing products under this
�, �• ,�� i
report.
seal
11 � • KATE OF
"'� �•° '�11OR1UY' °'ate' -
°s�c�,•p. .•� �� o.
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6t' ed..
2. Minimum slope to be compliant with Florida Building Code 2017 6t' ed., and per with Manufacturers installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities wludsdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6"' ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural
Loading. i
7. This report does not imply warranty, installation, recommended product use outside of this report.
FL 17022.5 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details
16"
—F—
�_ � 3/4_�
Panel Profile
16" o. c.
fA
Deck:
-15/32" or greater Plywood, or
- Wood plank
Integral Snap Lock
For METHOD 2:
Apply 3116" Bead Bostik 915111" Sealant
Continuous Along Male Rib Vertical Flange
�.\ Fastener
#10 x 1" Min. per Table "A"
Pancake Head Wood Screw
(Typical Fastening Pattern Across Width)
FL 17022.5 1.0 Nail Strip (266A Steel),16" Wide Roof Panel - Details
1" Nail Strip Roof Panel
Deck:
-15/32" or greater Plywood, or
- Wood plank
Fastener ----\
#10 x.1" Min. per Table "A"
Pancake Head VVood Screw
i
Isometric View
i
Seam Adhesive Application:
For Method 2
Apply 3/16" Bead Bostik 915Tm Sealant
Continuous Along Male Rib Vertical Flange
(Refer to Table "A")