Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFFlorida Building Code Online Page 1 of 4 r SCANNED 13Y i St Lucie Countv ' -r s BaS Home ' Log In I User Registration Hot: Its Submit surcharge Stats & Facts i Publications I Fac surf f Bas site Map j Units I search +;r Product Approval 0 . USER: Public User i RECEIVED ' A li ti n D it Sea Product Approval Menu > Product or Application Search > Apolica[ron t > pp ca a FL.# ` FL17022-R7 MAY 01 201� Application Type Revision rmitting Code Version 2017 ST. Lucie County, Pe Application Status Approved Comments 08/18/2017v. date reapply 08/21/17 Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method i Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Extreme Metal Fabricators, LLC 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 Rvalidation@yahoo.com Richard McKuhen Rvalidation@yahoo.com Richard McKuhen 2160 SW Poma Drive BT LUCA'!C LINTY ' Palm City, FL34990 4aUILDIN0`NV.ISION.r,, (772) 872-8034 richard@emfab.net 63N/CICC1!/fsDD Pon Com, ..LO - MCE. 1`11EVIEVHD BY YJ PLANS AND ERMIT riLIST BE KEPT ON 'JOB OR Roofing NO INSPECTION WILL BE MADE Metal Roofing Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer =1 Evaluation Report - Hardcopy Received LOCKE BOWDEN PE-49704 Keystone Certifications, Inc. 04/22/2024 Zachary R. Priest, P.E. -A Validation Checklist - Hardcopy Received FL17012 R7 COI FL 17022 1 5 V CRIMP ssr.odf . Referenced Standard and Year (of Standard) Standard Year TAS 125 Z003 UL 1897 2012 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code.!,111n t, 0'P r-Ili-W f https://www.floridabuilding.org/pr/pr_app_dtl.aspx?pararn=wGEV XQwtDgv2aBQpHpQQ... 2/ 16/2018 Florida Building Code Online " Product Approval Method Method 1 Option:D' ...,.. `._.,. .. . . . Page 2 of 4 Date Submitted 08/18/2017 Date Validated 08/25/2017 Date Pending FBC Approval 08/28/2017 Date Approved 10/10/2017 Summary of Products FL # Model, Number or Name Description 17022.1 1 - "5V Crimp"'1(116) 26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel mechanically attached to 15/32" plywood or Wood Deck with fasteners Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes, Impact Resistant: No Design Pressure: +N/A/ -Table A other: Refer to evaluation report for conditions. Install the assembly in compliance with the Installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation Instructions. 17022.2 12 - "5V Crimp" (R6) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions.Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.3 13 - "1.5" Mechanical Seam" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report,and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.4 14 - "1.5" Mechanical Seam" (R5) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's Installation Instructions. 17022.5 15 - "1 in. Nail Strip" (R5) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other. Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with Installation Instructions• FL17022 R7 I1 FL 17022 1 5 V CRIMP ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL1702Z R7 AE FL 17022 1 5 -VCRIMP ssr.odf Created by Independent Third Party: Yes 0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel, mechanically attached to 15/32" plywood or Wood Deck with exposed fasteners Installation Instructions. FL17022 R7 II FL 17022.2 5 V CRIMP 0 032 ALUM ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssr.odf Created by Independent Third Party: Yes 1.5" rib height, 16" wide, 24 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with clips and fasteners. Installation Instructions FL17022 R7 11 FL 17022 3 1 5 M HC ANICAL seam 24aa ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.3 1.5 MECHANICAL - seam 24aa ssr.odf Created by Independent Third Party: Yes 1.5" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to 15/32" plywood or Wood Deck with Gips and fasteners. Installation Instructions FL17022 R7 II Fi 17022.4 MECHANCIAL SEAM ALUMINUM ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM ALUMINUM ssr.odf Created by Independent Third Parry: Yes 1" rib height, 16" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Installation Instructions FL17022 R7 II Q1 17022.5 1.0 NAILSTRIP SS a f_ Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022 S. 1 0 NAILSTR P ssr.odf Created by Independent Third Party: Yes https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQw-tDgv2aBQPHPQQ•.• 2/16/2018 Florida Building Code Online Page 3 of 4 the Installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation 17022.6 . 16 - "1 In. Nail Strip" (115) i Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly, in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturers installation instructions. 17022.7 17 - "1.5 in. Nail Strip" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. I 17022.8 18 - "EMAX Rib" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other. Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation Instructions. 17022.9 19 - " PBR MAX" Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturers installation instructions. 1" rib height, 16" wide, 0.032 aluminum, standing seam roof panel mechanically attached to attached to 15/32" plywood or Wood Deck with fasteners, Installation Instructions FL17022 R7 I1 FL 17022.6 1.6 NAIL STRIP 0.032 ALUM ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 P.7 AE FL 17022.6 1.0 NAIL STRIP 0.0.32_ ALUM ssr.odf Created by Independent Third Party: Yes 1.5" rib height, 19" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Installation Instructions FL17022 R7 I1 FL 17022.7 1.5 Nail Strip 26GA ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 _ R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.pdf Created by Independent Third Party: Yes 29 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Installation Instructions FL17022 R7 I1 FL 177022.6 EMAX Rib ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 177022.8 EMAX Rib ssr.pdf Created by Independent Third Party: Yes 26 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Installation Instructions FL17022 R7 II FL 17022.9 PBR RIB_ ssr.ndf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE_ FL 17022.9 PBR RIB ssr.pdr Created by Independent Third Party: Yes F--ckl Nezt Contact Us :: 2601 Blair Ston Road Tallahassee Fl. 32399 Phone: 850-487-1624 The State of Florida is an AA/EEO employer. r_ot'vriaht 2007r2013State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. It you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for omdal communication with Me licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please dick berg. Product Approval Accepts ®ft-111201—® Credit Card Safe https://www.floridabuilding. org/pr/pr_app_dtl.aspx?param=wGEV XQwtDgv2aBQpHpQQ... 2/16/2018 - 2160 SW Poma Drive Palm City, FL 34990 Compliant with Florida Building Code 2017 (6tl' ed.) Compliant with Florida Product Approval Rule #-61G20-3 Compliant: Keystone Certifications Product: 1" Nailstrip 26GA Steel Roof Panel FBC Sec. 1507.4.2 Yield strength: 50 ksi min.; Attached to min.15/32"' plywood or Wood Deck w/ 0.42 specific gravity with 16" Coverage (Max.) Rib Height 1" Corrosion Resistant Compliant: FBC Sec.'1507.4.3 Fastener 1: #10 x 1" (min.) Pancake Head' Wood Screw to penetrate 3/16" (min.) thru bottom of support. Adhesive/Sealant : Bostik 915`4 Chem -Chalk one component, polyurethane adhesive with 3/16" continuous bead application along base of male rib vertical flange at each panel seam. Underlayment: To be compliant with FBC Sec 1507.1.1 Slope: Shall be in compliance with FBC Sec.1507. 1 install Details: Table A _ Allowable Loads METHOD 1 ( METHOD 2 j DESIGN PRESSURE* i -86 PSF Main field -97.25 PSF Perimeter j } FASTENER SPACING ( 6" O.C. 6" O.C. i SEAM ADHESIVE i Not required 3/16u continuous bead Reference Data: ARCHITECTURAL TESTING, INC. TST ID#'- 1527 UL 580-06 & UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen #1 & #2 ,EQUIVALENCY.• UL1897-04 is equivalent to Test Standard UL1897-12. *Design Pressure. ma of safety?:1 Certificate of independence: Locke Bowden, P.E. does not have, not will acquire a financial i��gstur ogy�company manufacturing or distributing products under this evaluation. ��``�,L D'.Bl'i O;.Y: ,'O1, Locke Bowden, P.E. is not owned, operated, or controlle��eM,Y�Ctmpi dtan' cturer, or distributing products under this report. - r " .•� . ` _. ..... � o " sea( cc =: �� STA' c OF .. "0NAI- i Limitations: 1. Underiayment to be compliance with, current Florida`Building Code (FBC)2017 60' ed.. 2. Minimum slope to be compliantwith Florida BuildingiCode 2017 6u' ed., and per with Manufacturer's installatiori'�efererice: 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method:1-D 4. Engineering analysis for "project specific approval by,local authorities wlurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear' diaphragm values are outside this report 6. Support framing in compliance w/FBC 2017 V' ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report FL 170&6 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details ' 16" 3/41 Panel Profile 16' O.C. I Deck: -15/32" or greater Plywood, or - Wood plank Integral Snap Lock i i For METHOD 2: Apply 3/1G' Bead Bostik 915TM' Sealant Continuous Along Male Rib Vertical Flange _._. -,� Fastener #10 X 1" Min. per Table "A' Pancake Head Wood Screw (Typical Fastening Pattern Across Width) Limitations: 1. Underiayment to be compliance with, current Florida`Building Code (FBC)2017 60' ed.. 2. Minimum slope to be compliantwith Florida BuildingiCode 2017 6u' ed., and per with Manufacturer's installatiori'�efererice: 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method:1-D 4. Engineering analysis for "project specific approval by,local authorities wlurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear' diaphragm values are outside this report 6. Support framing in compliance w/FBC 2017 V' ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report FL 170&6 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details ' 16" 3/41 Panel Profile 16' O.C. I Deck: -15/32" or greater Plywood, or - Wood plank Integral Snap Lock i i For METHOD 2: Apply 3/1G' Bead Bostik 915TM' Sealant Continuous Along Male Rib Vertical Flange _._. -,� Fastener #10 X 1" Min. per Table "A' Pancake Head Wood Screw (Typical Fastening Pattern Across Width) FL _17022.5 1.0 Nail Strip (26GA Steel),16" Wide Roof Panel - Details Fastener #10 X 1" Min. per Table "A' Pancake Head Wood Screw 1" Nail Strip Roof Panel Deck: -15/32" or greater Plywood, or - V\bod plank Isometric View Seam Adhesive Application: For Method 2 Apply 311V' Bead Bostik 915Tm Sealant Continuous Along Male Rib Vertical Flange (Refer to Table " A')