8C NN5r)
• MIAMI-DADS St Lucie Go unty
MwMI-DADE COUNTY
i
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION 1
Miami, Florida 33175-2474
NOTICE OF. ACCEPTANCE (NOA,
T (786) 315-2590 F (786) 315-2599
v~.mlamidade.sov/economy
Sunlast Metal, Inc.
2120 SW Poma Drive
Palm City, FL. 34990
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used'in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for duality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code. J
This product 1s approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricanel Zone of the Florida Building Code.
DESCRIPTION: 5-V-Crimp .032"IAluminum (min) over %" (min) plywood
1
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall belconsidered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA (will occur after the expiration date or if there has been a revision or change in the
materials, use, acid/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of
shall be available for inspect
This NOA consists of
The submitted documi
entire NOA shall be provided to the user by the manufacturer or its distributors and
at the job site at the request of the Building Official.
through 5.
was reviewed by Carlos M. Utrera, P.E.
NOA No.:15-0212.07
Expiration Date, 04/30/20
Approval Date: 04/30/15
Page 1 of 5
0
J
ROOFING SYSTEM APPROVAL:
Category:
Roofing
Sub -Category:
Metal, Panels (Non -Structural)
Material:
Aluminum
Deck Type:
Wood
Maximum Design Pressure: -176 psf
MADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Product Dimensions Specifications Description
.032" Aluminum L = varies', TAS 110 .032" (min.) Aluminum preformed metal
S-V-Crimp Metal W = 20.5"-24" panels, painted or unpainted.
Roof Panel H = %Z"
Min. Thickness 0.032"
Min Yield Strength: 23 ksi.
Fasteners #10 HWH of sufficient TAS 110 Stainless steel screw with capped hex head
length to penetrate through bonded washer.
sheathing a minimum of 3/16"
Trim Pieces L = varies TAS 110 Standard flashing and trim pieces.
W = varies Manufactured for each panel width.
Min. Thickness 0.032" inch.
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Architectural Testing, Inc. D9330.01-450-18 TAS 100 10/13/14
D9330.03-450-18 TAS 125 10/13/14
Valspar 433X515 ASTM B 117 11/21/11
433B173 ASTM D 4587, ASTM G 23 11/21/11
NOA No.: 15-0212.07
Expiration Date: 04/30/20
Approval Date: 04/30/15
Page 2 of 5
APPROVED ASSEMBLIES:
System A: 0.032" Aluminum 5-V-Crimp Metal Roof Panel —
HORIZONTAL LAPS ARE PERMITTED
Deck Type: Wood, Non -insulated'
Deck Description: New Construction 19/32" or greater plywood or wood plank, or for re -roofing 15/32" or
greater plywood.
Maximum Uplift See Table A below.'
Pressure:
Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less than Sd ring
shank nails spaced 6" o.c. In reroofing, where the deck is less than 19/32" thick (Minimum
15/32") the above attachment method must be in addition to existing attachment.
Underlayment: Minimum underlayment shall be an ASTM D 226 Type 11 installed with a minimum 4" side -
lap and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps and 12
gauge 1 1/4" annular ring -shank nails, spaced 6" o.c. at all laps and two staggered rows 12"
o.c. in the field of the roll. Or, any approved underlayment having a current NOA.
Fire Barrier: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for
fire ratings of this roofing system assembly as well as the location of the fire barrier within
the assembly. See Limitation # 1.
J �
Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and
with PAC Contractors Association's current published installation instructions.
Metal Panels and Install the ".032" Aluminum 5-V-Crimp Metal Roof Panels" and accessories in compliance
Accessories: with PAC Contractors Association's current, published installation instructions and details.
Flashing, penetrations, valley construction and other details shall be constructed in
compliance with the minimum requirements provided in Roofing Application Standards RAS
133.
Panels shall be fastened with corrosion resistant #10 HWH screws of sufficient length to
penetrate through the sheathing a minimum of 3/16". Fasteners shall be installed parallel to the
roof slope along the panel's overlapping ribs (fastening of the center rib is optional) at a
maximum spacing as listed in Table A below.
TABLE A
MAXIMUM DESIGN PRESSURES '
Field
Perimeter and Corner[
Maximum Design Pressure
-74.75 psf
-176 psf
Maximum Fastener Spacing
16" o.c.
8" o.c.
1. Extrapolation shall not be allowed
NOA No.: 15-0212.07
Miara•na�Ecourmr Expiration Date: 04/30/20
Approval Date: 04/30/15
Page 3 of 5
LIMITATIONS
i
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters,
and corners). Neither rational analysis, nor,' extrapolation shall be permitted for enhanced fastening at enhanced
pressure zones (i.e. perimeters, extended corners and corners).
3. Panel shall be roll formed in continuous, lengths from cave to ridge. Maximum lengths shall be described in the
Roofing Application Standard RAS 133.,HORIZONTAL LAPS ARE PERMITTED
4. All panels shall be permanently labeled with the manufacturer's name and/or logo, city and state of
manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved" or with
the Miami -Dade County Product Control Seal as seen below. All clips shall be permanently labeled with the
manufacturer's name and/or logo, and/or model.
1 M1AMl-DADE COUNTY
I
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
• 6. Panels may be shop or jobsite roll formed with machine model #10120107, 8560904, or RF6631 from PAC
Contractors Association.
j NOA No.: 15-0212.07
MIAMI•DAD@COUNTY Expiration Date: 04/30/20
Approval Date: 04/30/15
Page 4 of 5
PROFILE DRAWINGS
STIFFENING RIBS AND/OR STRIATIONS ARE OPTIONAL
j
!)IRA r—
PANEL MATERIAL
Steel & Alumhum
MIN. PANEL THICKNESS
24gs &.032';Alumnum
PANEL WIDTH
20-& to 24.011 Coverage
PANEL RIB HEIGHT
318" MInImum
ME�FASTENERPATTE�RNSIj
PANEL FASTENERS:
110 Flax Hesc! 'Alcad Scrffms
w."Alowhar SBallno Wsshprs,
20.5'- 24.
Fbbs & Panel Striarmns um Optcnal
..... ... ...
. ...... ...
Fut mustlicliu pinpuarm6, fuslu-nom
In ihu contui i1b aru cpfluuml
PAC CONTRACTORS
A,59910 C.1 451 T � 0 N
END OF THIS ACCEPTANCE
I
NOA No.: 15-0212.07
Expiration Date: 04/30/20
Approval Date: 04/30/15