HomeMy WebLinkAboutARCHITECTURAL SITE PLANEL: 1.3' BOTT OF 12" CMP CULVERT 6" CONC APRON EL: 3.9' YI i III I I I . 0 I 6" rock cl 4" CONC I 'ice I j o 1 0 N (1) 0 EXTG SWALE TO REMAIN AS IS - EDGE OF DIRT RW WINI)HAM LANI-- A RETAINING WALLAS PER DETAIL 25' FY setback �7 1 7.5' SY setback 4" CONC 20' SY setback 125' (S64039'41"W) ALL MANUFAMR18 LAKE$ SHOWING U FACTORS AND SHGC OOMPUANCE WITH FBC ENERGY OODE MUST REMAIN ON ALL DOORS AND WINDOWS UNTIL INSPECTIONS ARE APPROVED CONCEALED IASTENERS OR ATTAC MENTS ARE TH RESPONSIBILITY OF E CO RACTOR OF RECORD 1 I I 0 15' RY set ack I r-- 20'-6„ j 6' UTILITY EASMENT 125' (S65-19'53"W) 0 48' 16' SITE PLAN NOTES: 1. GRADING AT ALL PERIMETER WALLS TO SLOPE 6" O'ER 10' AWAY FROM BUILDING /.� 2. SEE SURVEY FOR EXTG ELEVATIONSAND SITE UTIL-ES 3. TOP OF CONDENSING UNIT PAD TO BE AT S EL 4. TREES TO MEET JURISDICTION'S SHADE TREE REOIREMENTS ;T M 0 LO LI J THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY MELD INSPECTORS THAT MAY BE N90088ARY IN OROER TO GRADE AS PER SITE PLAN COMPLY WITH ALL APPLICABLE 04gEA, -� ,. I e�• 8x8x16 CMU WALL W/#4 @ 64" OC. TOP COURSE CONT MASONRY BOND BEAM W/ (1) #4 Ni II s + 1 i i NEIGHBOR'S �se° }, SUBJECT PROPERTY 1{{ PROPERTY I a w !� ���✓� r r y/�j fi I o 'CONC FOOTINGW (2) `I + ,�L � _7'L� RETAINING WALL DETAIL SCALE: 1"= V-0" FAN SHEETINDEX A-1 site plan A-2 general notes A-3 foundation plan A-4 framing plan A-5 floor plan A-6 power/RCP A-7 elevations A-8 HVAC PROJECT DESCRIPTION NEW CONSTRUCTION OF A 1 STORY RESIDENCE ON A VACANT LOT Martin & Joyce Riccio 300 10th AVE Belmar, NJ 07719-2313 ARCHITECT Frank Liebler Owner / Architect / Contractor Site & Studio, Inc.. Construction + Architecture CRC1331263 I AA26003142 frank.liebler@gmail.com c 772.321.4500 ZONING INFORMATION: parcel id: 1436-602-0010-000-3 RS-4 (unincorporated St Lucie County) setbacks: front = 25' 1 side = 7.5' rear = 15' height: 35' corner side = 20' lot (approx.): 95'xl25' flood zone: AE 4ft UTILITY INFORMATION; gas: not used sewage: septic TERMITE TREATMENT REQUiREQ potable water: public AREA CALCULATIONS: conditioned living area 2,275 sf garage 579 sf covered porch 195 sf covered entry 57 sf added building area 3,106 sf existing building area 0 sf total building area 3,106 sf allowable building area 30% 3,563 sf lot area 11,875 sf buildable area 5,737 sf conditioned volume 21,636 cf CODE COMPLIANCE: This project was designed under the following codes. The constrcuction documents can not reference all of the codes require for the construction of this building. By submitting these construction documents for permit, the contractor, hereby agrees to comply with all local, state, and federal regulations having jurisdiction over this project, and to comply with all governing codes, including but not limited to, the most current editions as adopted by the state of florida, of the following: 2017 FBC: RESIDENTIAL 2017 FBC: EXISTING BUILDING 2017 FBC: ENERGY CONSERVATION 2017 FBC: PLUMBING/ GAS/ MECHANICAL 2014 NATIONAL ELECTRIC CODE GENERAL SPECIFICATIONS: 1. SLAB ON GRADE: AS PER GENERAL NOTES. 2. ROOF: METAL OVER PEEL & STICK OVER 30# FELT OVER 5/8" CDX PLY OVER PE WOOD ROOF TRUSS AS PER FRAMING PLAN W/ R20 SPRAYFOAM TO ROOF DECK 3. EXTERIOR WALL: STUCCO OVER 8x8x16 CMU W/ #5 VERT REBAR @ 48" OC & HORIZ JOINT REINFORCEMENT @ 16" OC- CONT BOND BEAM TOP COURSE W/#5 REBAR- 5/8" GWB OVER 3/4" FURRING STRIP @ 24" OC OVER CONT 1" RS MIN RIGID INSULATION. DOWELS AS PER GEN NOTES. 4. INTERIOR NON LOADBEARING WALLS: 5/8" OR 1/2" GWB OVER 3 5/8" METALSTUD OR 2x4 @ 16" OC, 20GA MIN METAL STUD FOR WALL HUNG CABINETS. 5. INTERIOR 2x4 LOADBEARING WALLS: 5/8" GWB OVER 2x4 @ t6" OC, EA STUD TO PLATES W/ SIMPSON TSP OR SP4. SILL PLATE TO FOUNDATION W/ SIMPSON 1/2"x5" TITEN HD @ 32" OC-12" OF JOINTS. LINTELS TO BE (2) 2x12 VERT UNO, DOUBLE JACKS FOR OPENINGS WIDER THAN 4'. EA TRUSS TO TOP PLATE W/ SIMPSON H14, USE (2) FOR GIRDERS, DOUBLE STUDS UNDER GIRDERS. 6. INTERIOR 2x6 LOADBEARING WALLS: 5/8" GWB OVER 2x6 @ 16" OC, EA STUD TO PLATES W/ SIMPSON TSP OR SP6. SILL PLATE TO FOUNDATION W/ SIMPSON 1/2"x5" TITEN HD @ 32" OC-12" OF JOINTS. LINTELS TO BE (2) 2x12 VERT LINO, DOUBLE JACKS FOR OPENINGS WIDER THAN 4'. EATRUSS TO TOP PLATE W/ SIMPSON H14, USE (2) FOR GIRDERS, DOUBLE STUDS UNDER GIRDERS. 7.CEILING: 1/2" OR 5/8" GWB OVER WOOD PE TRUSS BOTTOM CHORD 8. EXTERIOR SOFFIT: NON -VENTED STUCCO & LATH OVER FRAMING. 9. PROVIDE MANUFACTURED CONCRETE PAD AND BRACKETS RATED FOR SPECIFIED WIND LOAD FOR CONDENSING UNIT 10. GARAGE DOOR BUCKS TO BE INSTALLED/ATTACHEDAS PER MFR SPECS 11. R-19 SPRAY FOAM INSULATION @ GARAGE SEPARATING WALL, FLOOR TO ROOF DECK. PROVIDE ACCESS HATCH TO CONNECT ATTIC SPACES. R-13 SPRAY FOAM TO CEILING, OR R-19 BATT W/ HOUSE WRAP, @ ALL OTHER EXTERIOR CEILNGS. 1 1 ;. c •1- � ► ya (ILJ Nt, INIPiCTtO: SCANNED BY St Lucie County FDOH in St. Lucie County Environmental Health Site Plan Approved for Construction Supersedes All Previous Site Plans for OSTDS A$b•�F I`6"}Sk4ggWeM�— te: I / avie er: L � ci 0s =w o�?.0 rZWO ° - ° Lo16� ate.+"'N In — � In 0 M N N 0 �W` H r C � 0Wcc W "Z Q L. 0 Z V W 0 Z W Z //0 Vi ll LU I.L. �U V l F W 2 2 O 0 w H 0 0 site plan MAR 31, 2018 SHEET A-1 ARCHITECTURAL SITE PLAN SCALE: 1/8"= T-0" Fide AR97108 H L LL C Q D C u C F--3 BASIS OF STRUCTURAL DESIGN: SOIL BEARING: 2000 psf (assumed) WIND: 161 mph (ultimate), risk category 2, exposure C, wind borno debri region, enclosed design FROST DEPTH: 12" - THE STRUCTURAL DESIGN APPROACH FOR MASONRY, ROLLED STEEL, AND LIGHT WEIGHT STEEL IS WORKING STRESS DESIGN. THE DESIGN APPROACH FOR REINFORCED CONCRETE IS ULTIMATE STRENGTH DESIGN. THE DESIGN SERVICE LOADS ARE AS FOLLOWS: ROOF LIVE LOAD 20 PSF(slope<4:12), 15 PSF(slope>_4:12) ROOF DEAD LOAD 15 PSF ROOF WIND LOAD (SEE DRAWINGS) CEILING DEAD LOAD 10 PSF WALL WIND LOADS (SEE DRAWINGS) FLOOR DEAD LOADS 15 PSF FLOOR LIVE LOADS SEE BELOW FLOOR LIVE LOADS Uninhabitable attics without storage 10 Uninhabitable attics with limited storage 20 Habitable attics and attics served with fixed stairs 30 Balconies (exterior) and decks 40 Fire escapes 40 Guardrails and handrails 200 Guardrail in -fill components 50 Passenger vehicle garages 50 Rooms other than sleeping room 40 Sleeping rooms 30 Stairs 40 GENERAL NOTES ARCHITECT & CONTRACTOR RELATIONSHIP - Y CONTRACTOR, THE UNLESS CONTRACTED DIRECTLY B C ARCHITECT AND CONTRACTOR T IN A CONTRACTUAL FACTOR ARE NO RELATIONSHIP. HOWEVER, BY SUBMITTING THESE CONSTRUCTION DOCUMENTS FOR PERMIT, THE CONTRACTOR ACKNOWLEDGES THAT THEY ARE COMPETENT AND LINE ERSTAND THE DOCUMENTS. IF THE CONTRACTOR VEERS FROM THESE PLANS, THEY ARE ACCEPTING LIABILITY THAT W YARISE DUE TO CHANGES. ARCHITECT IS NOT LIABLE FOR THE CONTRACTOR'S INCOMPETENCY TO UNDERSTAND THE ONSTRUCTION DOCUMENTS. WORKMANSHIP & WARRANTY: - THE FOLLOWING GENERAL & SPECIFIC NOTES SHALL AF PLY EQUALLY TO ALL CONTRACTORS, SUBCONTRACTORS AND SUPPLIERS ENGAGED IN EXECUTION OF WORK ON THE E PLANS. - IT SHALL BE THE DUTY OF EACH SUBCONTRACTOR WHO REQUIRES CHASES OR OPENINGS OF ANY KIND FOR HIS WORK, WHETHER SHOWN ON THE DRAWINGS OR NOT, TO SEE HAT THEY ARE PROPERLY CONSTRUCTED AND IN THE CASE OF FAILURE, IT SHALL BE THE DUTY OF SAME SUBCONTRACTOR TO CUT, SUCH CHASES OR OPENINGS AS MAY BE NECESSARY AND PROPER FOR HIS OWN WORK AT HIS C WIN EXPENSE, BUT NOT WITHOUT OBTAINING THE APPROVAL OF THE GENERAL CONTRACTOR. -EACH SUBCONTRACTOR SHALL, WHERE WARRANTIES D GUARANTEES ARE REQUIRED, SECURE AND DELIVER COPIES TO THE GENERAL CONTRACTOR UPON COMPLETION OF THE WORK. THE GENERAL CONTRACTOR WILL COMPILE THE WARRANTY AND GUARANTEE INFORMATION AND DELIVE R TO THE OWNER ATTHE DATE OF ISSUANCE OF CERTIFICATE OF OCCUPANCY. - EACH SUBCONTRACTOR SHALLAND DOES HEREBY WAF RANTYAND/OR GUARANTEES ALL WORKAS APPLIED TO HIS PARTICULAR TRADE FOR A PERIOD OF ONE YEAR FROM THE DATE OF COMPLETION, AS EVIDENCED BY THE DATE OF ISSUANCE OF CERTIFICATE OF OCCUPANCY. -ALL MOVEABLE OR ADJUSTABLE WORK SHALL REMAIN I PERFECT WORKING ORDER FROM ONE YEAR OF THE DATE OF CERTIFICATE OF OCCUPANCY, INCLUDING HARDWARE, EATHER- STRIPPING, DOORS, WINDOWS, DRAWERS, APPARATUS, MACHINERY, ELECTRICAL EQUIPMENT, ANM ALL OTHER EQUIPMENT TO WHICH THIS HEADING IS APPLICABLE. WHEREIN ANY DIVISION OF WORK ALLOWS A GUARANTEE OR WARRANTY FOR A PERIOD LONGER THAN ONE YEAR, SUCH WARRANTY OR GUARANTEE SHALL TAKE PI IECEDENCE. COORDINATION: -THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COC RDINATION OF WORK FOR ALL TRADES. -ALL SUBCONTRACTORS AND GENERAL CONTRACTORS MUST REVIEW COMPLETE SETS OF DRAWINGS, SPECIFICATIONS, ADDENDA, AND ALL OTHER PORTIONS OF THE COMPLE1 E CONSTRUCTION DOCUMENTS. YOUR SECTION'S WORK MAYBE SUPPLEMENTED BY OTHER SECTIONS. OTHER SECTIO OF THE DOCUMENTS MAY CONTAIN ITEMS THAT ARE PART OF YOUR BID, OR, MAY CONFLICT WITH YOUR SPECIFIC SE TION. YOU ARE TO INCLUDE THE MOST STRINGENT LY T REQUIREMENTS. IN PARTICULAR, CLOSECOMPARE E PLUMBING, HVAC, AND ELECTRICAL SECTIONS WITH THE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS. IN PARTICULAR, LOOK AT THE ARCHITECTURAL FLOOR PLAN(S), REST -ROOM ELEVATIONS, AND INTERIOR ELEVATIONS. Ir THE EVENT THAT THE ARCHITECTURAL PLAN (OR OTHER PLANS, ETC.) INDICATES ITEMS NOT CONTAINED WITHIN YOUR I ORMAL SECTION, ALLOW FOR THESE ITEMS IN YOUR BID. CONTACT THE ARCHITECT WITHIN 10 DAYS PRIOR TO BI DATE TO ALLOW ISSUANCE OF ADDENDUM (IF APPLICABLE). IN OTHER WORDS, THE ARCHITECTURAL OR OTHER SECTI DNS MAY OR MAY NOT CONTAIN ADDITIONAL OR CONFLICTING WRITTEN OR GRAPHIC INFORMATION ABOUT YOUR. TRA E. PROVIDE FOR EVERYTHING INDICATED OR IMPLIED (BY CODE) RESULTING AS A COMBINATION OF THE INFORMATION F ZOM THE ENTIRE SET OF CONSTRUCTION DOCUMENTS, NOT JUST YOUR TRADITIONAL SEPARATE SECTION. IN CASE OF CONFLICT, NFLICT, THE MOST STRINGENT ITEM SHALL GOVERN, WITHOUT ADDITIONAL COST TO THE OWNER. HOWEVER, THIS DO S NOT RELIEVE THE CONTRACTOR FROM CALLING IT TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION. - CONTRACTORS SHALL REVIEW ALL DRAWINGS AND SPECIFICATIONS PRIOR TO MAKING BIDS. BY MAKING BIDS, CONTRACTORS ARE IN EFFECT AGREEING THAT THEY HAVE DONE THIS. A DRAWING MAY INADVERTENTLY OMIT SOME RELATED ITEM FROM ANOTHER DRAWING. THIS DOES NOT MEAN THATTHE SECONDARILY OMITTED ITEM IS NOT REQUIRED IN SO FARAS ITAFFECTS THE TRADES. ALL I FADES SHALL INCLUDE EVERYTHING NECESSARY FORA COMPLETE AND PROPERLY FUNCTIONING CODE - ACCE 3 TABLE PROJECT, UNLESS CERTAIN ITEMS ARE SPECIFICALLY INDICATED AS BEING PROVIDED BY OTHERS AS "NIC" (NOT IN CONTRACT). ABBREVIATIONS: - SEE ABBREVIATION LIST FOR DEFINITIONS WHICH ARE L BED IN THESE DRAWINGS AND SPECIFICATIONS. CONDITIONS NOT DETAILED: - CONSTRUCTION DOCUMENTS CANNOT DETAIL EVERY C D NDITION OR INSTRUCT THE CONTRACTOR ON HOW TO PERFORM THE WORK. EVERY CONNECTION, CORNER, ASHING, ETC. MUST BE RESOLVED. THESE AND OTHER CONDITIONS SHALL BE HANDLED IN A MANNER COMPA7 BLE WITH THE REST OF THE WORK. NOTIFY ARCHITECT IF A CONDITION NEEDS ADDITIONAL DIRECTION OR DETAIL. VERIFY SITE INFORMATION: - CONTRACTOR IS TO VERIFY ALL SITE INFORMATION AN ASSUMPTIONS, ESPECIALLY SUBTERRANEAN CONCEALED CONDITIONS INVOLVING HIDDEN UTILITIES AND SOIL C ANY AFFECTING THE WORK BE DITIONS, SHOULD CONDITIONS DISCOVERED BY THE CONTRACTOR, HE IS TO NOTIFY T 4E ARCHITECT IMMEDIATELY. CONTRACTOR SHALL VERIFY THAT EXISTING SOILS MEET THE MINIMUM CAPACITY PER THE STRUCTURAL DESIGN. PRIOR TO ANY EXCAVATION WORK: - THE CONTRACTOR IS REQUIRED TO LOCATE ANY AND A L UTILITIES IN OR UNDER CONSTRUCTION, AND MAKE ARRANGEMENTS FOR THEIR LEGAL. RE-ROUTING, AS AC CEPTABLE TO GOVERNING AGENCIES, AUTHORITIES, UTILITIES AND OWNER. CONTACTALL AFFECTED UTILITY COMPAN IES AND INFORM THEM OF THE IMPENDING CONSTRUCTION, AND OBTAIN THEIR ASSISTANCE IN LOCATING THEIR UTILITIE S. DIMENSIONS: - DIMENSIONS ON ARCHITECTURAL DRAWINGS MAY BE "F OUGH" OR "FINISH." SEE PLANS FOR REQUIREMENTS. ARCHITECTURAL DIMENSIONS SHALL TAKE PRECEDENC E OVER STRUCTURAL OR OTHER DIMENSIONS, IF NO OTHER CONFLICT RESULTS. DOCUMENT ANY SUCH DISCREPAN CIES TO ARCHITECT IN WRITING. HEIGHT ELEVATIONS: -BUILDING HEIGHT ELEVATIONS TYPICALLY USE THE MAI FLOOR SLAB AS ELEVATION U-0" (BUILDING ELEVATIONS MAYBE NOTED AS "BLDG EL. SEE SITE PLAN AND FLOO PLAN(S). SITE ELEVATIONS MAYBE BASED ON THE SURVEY, _'-_"). WHICH MAY USE MEAN SEA LEVEL, NAVD, OR OTHER HEIGHT AS A REFERENCE DATUM (SITE ELEVATIONS MAYBE NOTED AS: "SITE EL_'-_" (OR CIVIL) ON THE SITE PLAN OR FLOOR PLAN(S). ON OTHER DETAILED ARCHITECTURAL DRAWINGS, TYPICALLY ALL OTHER ELEVATIONS ARE BASED ON THE "BLDG EL" OF 0'4" AS THE MAIN FLOOR, OR THE FLOOR THE DETAILS ON, AND ARE NOT NECESSARILY NOTED AS "BLDG EL: CONSULT ARCHITECT FOR ANY QUESTIONABLE LOCATIONS PRIOR TO CONSTRUCTING. AMBIGUITY: - IN THE EVENT OF ANY AMBIGUITY OR QUESTION WITH F EGARD TO THE INTENT OF THE DOCUMENTS, THE ARCHITECT SHALL INTERPRET THE CONSTRUCTION DOCUMENTS. - IN CASE OF CONFLICTS BETWEEN ARCHITECTURAL AN STRUCTURAL DRAWINGS, CONSULT WITH ARCHITECT. IN CASE OF CONFLICT BETWEEN THE GENERAL NOTES AND THE SPECIFICATIONS, CONSULT WITH ARCHITECT, FLORIDA PRODUCT APPROVALS: -THE SUBMISSION OF REQUIRED NOTICES OF ACCEPTAICE (NOA) AND/OR PRODUCT APPROVALS ARE THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRA OR IS REQUIRED TO MAKE THESE AVAILABLEATTIME OF INSPECTION. GENERALSTRUCTURAL - ALL STRUCTURAL ELEMENTS MUST BE SECURELY IN PLACE FOR BUILDING AND INDIVIDUAL COMPONENT STABILITY. THE STABILITY OF THE STRUCTURE AND INDIVIDUAL COMPONENTS DURING THE CONSTRUCTION PROCESS IS THE RESPONSIBILITY OF THE BUILDING CONTRACTOR. - THE CONTRACTOR IS TO VERIFYALL EXISTING CONDITIONS IN THE FIELD PRIOR TO FABRICATIONAND STARTOF CONSTRUCTION. THE CONTRACTOR SHALL PROTECT AND MAINTAIN ALL CONSTRUCTION AND ITS CONTENTS. CAST -IN -PLACE CONCRETE -ARCHITECT OR ENGINEER OF RECORD TO BE NOTIFIED PRIOR TO POUR FOR INSPECTION BYARCHITECT OF REINFORCEMENT FOR OVERHEAD BEAMS AND SLABS - CONCRETE PROPORTIONING, PLACING, FINISHING AND CURING SHALL BE AS PER THE LATEST EDITION OF THE PCA MANUAL. LEAVE SUPPORT FOR ELEVATED CONCRETE IN PLACE UNTIL THE CONCRETE HAS REACHED ITS DESIGN STRENGTH: -OVERHEAD SLABS AND BEAMS TO BE 4000 PSI CONCRETE MIN UNO -COLUMN AND WALL CONCRETE TO BE 3000 PSI CONCRETE MIN UNO -FOOTINGS TO BE 3000 PSI CONCRETE MIN UNO - CONCRETE, WHEN PLACED, SHALL HAVE A SLUMP OF 6 INCHES MAXIMUM AND 1 INCH MINIMUM EXCEPT FOR SLABS ON -GRADE WHICH SHALL HAVE MAXIMUM SLUMP OF 5 INCHES AND A MINIMUM OF 3 INCH. - ALL REINFORCING SHALL CONFORM TO ASTM 615 FOR GRADE 60 STEEL; WELDED WIRE MESH TO ASTM A-185. ARRANGEMENT AND BENDING OF REINFORCING STEEL SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE ACI DETAILING MANUAL AND THE CONCRETE REINFORCING STEEL INSTITUTE. DON'T SPLICE IN MIDDLE 1/3 OF BEAM OR COLUMN SPAN, IF A SPLICE IN SPAN IS UNAVOIDABLE, FOLLOW DEVELOPMMENT LENGTH/LAP DISTANCE IF NOT NOTED VERIFY W/ ARCHITECT - CHECK ALL DRAWINGS AND APPLICABLE MANUFACTURER'S SHOP DRAWINGS FOR LOCATION OF ALL EMBEDDED ITEMS SUCH AS PIPE SLEEVES, ANCHOR BOLTS, ETC., PRIOR TO PLACING CONCRETE. - PROTECT FRESHLY PLACED CONCRETE FROM PREMATURE DRYING AND EXCESSIVE COLD OR HOT TEMPERATURES. START INITIAL CURING AS SOON AS FREE WATER HAS DISAPPEARED FROM THE CONCRETE SURFACE AFTER PLACING AND FINISHING. KEEP CONTINUOUSLY MOIST FOR NOT LESS THAN 7 DAYS IN ACCORDANCE WITH ACI 301 PROCEDURES. PERFORM CURING OF THE CONCRETE BY CURING AND SEALING COMPOUND, BY MOIST CURING, BY MOISTURE RETAINING COVER CURING OR BY COMBINATION THEREOF. - SEE THE DRAWINGS FOR CONCRETE COVER FOR REINFORCING STEEL, BUT IN NO CASE SHALL THE COVER BE LESS THAN THAT REQUIRED BY AC1318: -CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH; 3" -CONCRETE EXPOSED TO EARTH OR WEATHER: #5 BARS AND SMALLER, 1 1/2" INCHES; #6 BARS AND LARGER, 2" - CONCRETE SLAB ON GRADE CONTROL JOINTS SHALL BE AS SHOWN ON THE FOUNDATION PLAN OR TYPICAL DETAILS. WHERE CONTROL JOINTS ARE NOT SHOWN ON PLANS, ALL CONCRETE SLABS ON GRADE SHALL BE BOUND BY KEYED, DOWELED OR SAW -CUT CONTROL JOINTS SUCH THATTHE ENCLOSED AREA DOES NOT EXCEED 260 SQUARE FEET. POST -TENSIONED CONCRETE SLABS ON GRADE SHALL NOT HAVE CONTROL JOINTS UNLESS SPECIFICALLY NOTED ON THE PLANS. EXPANSION JOINT FILLER SHALL BE NON -EXTRUDED PREMOLDED MATERIAL OF ASPHALT IMPREGNATED FIBERBOARD (ASTM D1751) - CONSTRUCTION JOINTS OR POUR JOINTS IN STRUCTURAL ELEMENTS (BEAMS, COLUMNS, ELEVATED SLABS, ETC.) NOT SPECIFICALLY SHOWN OR NOTED ON THE DRAWINGS REQUIRE PRIORAPPROVALOF THE ARCHITECT. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS SHOWING PROPOSED JOINTS TO ENGINEER FOR APPROVAL. /_\�SiZi7�[y7 �IF���4MIj�L�ta�:LLII�ILUPIL[s7�3rY.11yA/_F9CNZi - VERTICAL AND HORIZONTAL REINFORCEMENT SHALL BE PROVIDED AS SHOWN ON THE DRAWINGS. PLACE VERTICAL REINFORCING BARS AT CORNERS, JAMBS OF OPENINGS, BELOW BEAM BEARING, AND IN WALLS AS INDICATED ON THE DRAWINGS. VERTICAL WALL REINFORCING BARS SHALL EXTEND CONTINUOUS FROM FOUNDATION INTO TOP BOND BEAM. MIN LAP SPICES, EMBEDMENT, AND END HOOK LENGHTS AS PER ACI 318 OR FBC UNO. - -TIES/STIRRUPS TO STARTATA DISTANCE FROM SUPPORT OF 1/2 TIE SPACING CONCRETE MASONRY: - ALL MASONRY UNITS SHALL CONFORM TO THE REQUIREMENTS OF ASTM C90 FOR LOAD BEARING MASONRY WITH A MINIMUM fm OF 1500 PSI UNLESS NOTED OTHERWISE ON THE PLANS. - MASONRY STRENGTH D'm DESIGN): -BLOCK STRENGTH = 1 NO -MORTAR STRENGTH = 1800 -GROUT STRENGTH = 2010 - GROUT SHALL HAVEA SLUMP OF 8 TO 11 INCHES, BE IN CONFORMANCE WITH ASTM C 476-02 AND ATTAIN COMPRESSIVE STREN$TH OF 1800 PSLGROUT SHALL CONFORM TO REQUIREMENTS OF FLBC STANDARDS. USE FOR F - R T SUFFICIENT WATER GROUT TO FLOW INTO ALL JOINTS OF THE MASONRY WITHOUT SEGREGATION. ALL CELLS IN CONCRETE BLOCKS CONTAINING REINFORCING SHALL BE FILLED SOLID WITH GROUT. ALL MASONRY BELOW FINISHED FLOOR OR GRADE SHALL BE GROUTED SOLID. HOLD GROUT DOWN 1-1/2" BELOW TOP OF BLOCKATGROUTLIFTJOINTS ANDATCONCRETE PLACED OVER MASONRY. - CONCRETE MASONRY JNITS SHALL BE PLUMB, TRUE TO LINE, WITH LEVEL COURSES ACCURATELY SPACED AND BUILTTO THE THICKNESS AND IN A RUNNING BOND AS INDICATEDAND CONFORMING TO THE TOLERANCES SPECIFIED IN ACI 531.1AND 530.1. - REINFORCING BARS SHALL BE PLACED IN THE MIDDLE OF THE CELLS, UNLESS NOTED OTHERWISE, AND TIED OR OTHERWISE SECUPELY SUPPORTED ATTHE TOPAND BOTTOM TO ENSURE THATTHE BAR DOES NOT MOVE DURING GROUTING. - MORTAR DROPPINGS MD OTHER DEBRIS MUST BE KEPT OUT OF CELLS WHICH ARE TO BE GROUTED. - CONTROL JOINTS SHAD_ BE PROVIDED IN ACCORDANCE WITH THE LOCATIONS AND DETAILS SHOWN ON THE DRAWINGS. CONTROL DINTS SHALL NOT EXTEND THROUGH THE TOP BOND BEAM COURSE. THE JOINTS ON BOTH SIDES OF THE WA-L SHALL BE SEALED AND TOOLED SMOOTH. - WALL REINFORCEMEN-- VERTICAL AND HORIZONTAL REINFORCEMENT SHALL BE PROVIDED AS SHOWN ON THE DRAWINGS. PLACE VERTICAL REINFORCING BARS AT CORNERS, EA CELL WITHIN 16" OF CORNER, JAMBS OF OPENINGS, EA CELL WIYHIN 16" OF JAMBS FOR OPENINGS WIDER THAN 6% BELOW BEAM BEARING, AND IN WALLS AS INDICATED ON THE DRAWINGS. VERTICAL WALL REINFORCING BARS SHALL EXTEND CONTINUOUS FROM FOUNDATION 140 TOP BOND BEAM. MIN LAP SPICES, EMBEDMENT, AND END HOOK LENGHTS AS PER ACI 318 OR FBC UNO. SEE DOWEL NOTE BELOW. FOUNDATIONS: 1 - CONTRACTOR RESPWI3IBLE FOR IN -PLACE SOILS TO BE UNIFORMLY COMPACTED TO 95%AND TESTED TO ENSURE MINIMUM SOILBEARING PRESSURE CAPACITY OF 2,000 PSF UNO AS THE BASIS FOR STRUCTURAL DESIGN. - DOWEL VERTICAL REIFORCING BARS OUT OF THE FOUNDATION OR STRUCTURE BELOW WITH BARS OF THE SAME SIZE AND SPACIIG OF WALLABOVE. THERE SHALL BE A DOWEL FOR EACH VERTICAL REINFORCING BAR. MIN LAP SPICES, EMBEDMENT, AND END HOOK LENGHTS AS PER ACI 318 OR FBC UNO. For #5: MINIMUM 30" LAP W/ 10" HOOK UNO. SE WALL REINFORCEMENT NOTE ABOVE. -BUILDING SLABS -ON -GRADE TO BE REINFORCED WITH 6x6.10/10 WWF MIN WITH MESH UP CHAIRS OVER 6-MIL MINIMUM POLYETHYLENE FILM VAPOR RETARDER OVER TERMITE TREATED COMPACTED. GRADE UNO. PROVIDE DIAGONAL 36" #4 REB/R ATALL INSIDE'REENTRANTCORNERS. - CONTINUOUS FOOTINGS, STEM OR MONOLITHIC, TO BE REINFORCED CONTINUOUS, WITH LAPS AS PER STATED DEVELOPMENT LENG H IF NOTED OR 48x BAR DIAMETER MIN UNO. 30" MIN CORNERS BARS TO MATCH LONGITUDINAL REBAF - PROVIDE A4-INCH CLEAN MEDIUM TO COARSE SAND OR GRAVELCOMPACTED DRAINAGE FILL BELOW ALL INTERIOR SLABS -ON -GRADE UNLESS NOTED OR DETAILED OTHERWISE. -SOILAND SUBGRADE B TO BE TERMITE TREATED STRUCTURAL STEEL: - ALL STRUCTURAL STEIL SHAPES SHALL CONFORM TO ASTM A-36 AND THE "SPECIFICATION FOR THE DESIGN, FABRICATIONAND ERETION OF STRUCTURAL STEEL FOR BUILDINGS" BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION. ALL TEEL PIPE SHALL CONFORM TO ASTM A-53, TYPE E (Fy = 35 KSI). -ALL SHOP CONNECTIOIS TO BE WELDED AND FIELD CONNECTIONS TO BE MOLTED UNLESS OTHERWISE SPECIFICALLY NOTED iN THE STRUCTURAL DRAWINGS. ALL WELDING SHALL CONFORM TO THE REQUIREMENTS OF "TIE STANDARD CODE FOR WELDING IN BUILDING CONSTRUCTION" OF THE AMERICAN WELDING SOCIETY. - ALL STEEL TO RECEIVI ONE SHOP COATAND ONE FIELD TOUCHUP COAT OF APPROVED PAINT. - ALL BOLTED CONNECIONS SHALL CONSIST OF ASTM A325 HIGH STRENGTH BOLTS AND HARDENED WASHERS AS SHOWN ON THE SRUCTURAL DRAWINGS. ALL BOLTED CONNECTIONS SHALL CONFORM TO THE "SPECIFICATION FORSTRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS" BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION. - ALL ANCHOR BOLTS :HALL CONFORM TO ASTM A36 OR A307 (THREADED ROD). - SUBMIT SHOP DRAWNGS FOR REVIEW OF CONFORMANCE TO DESIGN CONCEPT. - GROUT FOR COLUMI` BASE PLATES SHALL BE NON -SHRINK GROUT 5000 PSI MINIMUM. LIGHT GAGE METAL SUDS & MISC. METAL FRAMING: - ALL LIGHT GAGE MEAL INTERIOR STUDS SHALL BE 20 GAGE MINIMUM. ALL LIGHT GAGE METAL TO BE GALVANIZED. ALL WAL TRACKS SHALL BE 20 GAGE. ALL LIGHT GAGE METAL SHALL BE G90. HVAC: - PLANS ARE SCHEM/rIC. EXACT LAYOUTAND SIZING OF UNITS, DUCTS, RETI RN AIR GRILLES AND SUPPLY GRILLES ETC, SHAL. BE DETERMINED BYA HVAC LICENSED CONTRACTOR AND APPROVED BY THE ARCHITECT. - FOR MOUNTING ANESECURING MECHANICAL EQUIPMENT, REFER TO THE MANUFACTURER's SPECIFICATIONS WOOD FRAMING -ALL STRUCTURAL (LOAD BEARING) LUMBER SHALL BE S. Y. P. OR DOUGLASS FIR, GRADE #2, KID 19% (Fb FOR LUMBER SIZES NOTED TO BE IN CONFORMANCE WITH VALUES LISTED IN THE NATIONAL FOREST PRODUCTS ASSOCIATION NATIONAL DESIGN STANDARD SUPPLEMENT TABLE 4B), AND SHALL CONFORM TO THE NATIONAL GRADING RULE FOR DIMENSION LUMBER, THE SOUTHERN PINE INSPECTION BUREAU AND THE SOUTHERN FOREST PRODUCTS ASSOCIATION. ALL NON -LOAD BEARING FRAMING LUMBER (INTERIOR WALLS) TO BE #2 S.P.F. OR BETTER. - PLYWOOD SHEATHING: -ALL PLYWOOD SHALL BE C-D OR C-C SHEATHING. INSTALL PLYWOOD WITH FACE GRAIN PERPENDICULAR TO SUPPORTS, PROVIDE BLOCKING AT PANEL EDGES WHERE INDICATED ON THE PLANS. -UPPER PANELS TO BE ATTACHED TO THE TOP MEMBER OF THE UPPER DOUBLE TOP PLATE AND TO RIM JOIST AT BOTTOM OF WALL. PROVIDE BLOCKING FOR ALL EDGE NAILING OVER LENGTH OF PLYWOOD -FOR EXTERIOR AND INTERIOR SHEAR WALLS USE 1/2" PLYWOOD AND 8d RINGSHANK GALV NAILS. SPACE NAILS 6" FIELD, T EDGE. -FOR ROOF USE 5/8" PLYWOOD AND 8d RINGSHANK GALV NAILS. SPACE NAILS 6" FIELD, 4" EDGE. -FOR SUBFLOOOR USE 7/8" PLYWOOD AND 2.5" #8 SCREWS & GLUE OR 8d RINGSHANK GALV NAILS & GLUE. SPACE FASTENERS 6" FIELD, 4" EDGE. - FIELD VERIFY WITH ARCHITECT EXACT LOCATIONAND CONFIGURATION BEFORE MODIFYING EXISTING TRUSSES. DO NOT CUTANY FRAMING MEMBERS OR TRUSSES WITHOUT EXPRESS WRITTEN AUTHORITY FROM THE ENGINEER AND ARCHITECT. - FIELD VERIFY DIMENSIONS OF NEW PRE-ENGINEERED TRUSSES PRIOR TO CONSTRUCTING. - CONTRACTOR TO SUBMIT THE TRUSS ENGINEERING TO ARCHITECT TO REVIEW FORADHERENCE WITH DRAWINGS PRIOR TO CONSTRUCTION. - TRUSS CONFIGURATION DRAWN ARE SCHEMATIC ONLY. EXACT TRUSS WEB, CHORD SIZES AND LAYOUTARE TO BE DETERMINED BY THE MANUFACTURER. TRUSS MANUFACTURER TO DESIGN ANY PERMANENT BRACING REQUIRED FOR STABILITY. -ALL TRUSSES FURNISHED SHALL BE SUPPLIED WITH SIGNED AND SEALED TRUSS DIAGRAMS PROVIDING THE MANUFACTURER'S TRUSS SPECIFIC REQUIREMENTS FOR BRACING AND LATERAL MOVEMENT. ALL TRUSS -TO - TRUSS CONNECTORS TO BE SUPPLIED BY THE TRUSS MANUFACTURER. VERIFY THATTHE CAPACITY OF THE TRUSS ANCHORS CALLED OUT ON THE CONSTRUCTION DRAWINGS MEET OR EXCEED THE UPLIFT VALUES ON THE TRUSS ENGINEERING. ANY TRUSS ANCHORS CALLED OUT THATARE OF INSUFFICIENT CAPACITY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR SUBSTITUTION. - PREFABRICATED WOOD TRUSSES, JOISTS, AND GIRDER TRUSSES SHALL BE DESIGNED TO SUPPORT THEIR SELF -WEIGHT, PLUS LIVE LOAD AND SUPERIMPOSED DEAD LOADS. INCLUDING, BUT NOT LIMITED TO, WALLS EITHER PARALLEL OR PERPENDICULAR TO THE SPAN, ALL MECHANICAL AND OTHER EQUIPMENT, AND SHALL DESIGNED TO RESIST ALL DRAG FORCES, SHEARWALL UPLIFT AND DOWNWARD LOADS, AND OTHER SPECIAL LOADS NOTED ON STRUCTURAL, MECHANICAL, PLUMBING, OR ARCHITECTURAL DRAWINGS OR CALCULATIONS, MINIMUM ALLOWABLE SHEAR SHALL BE95 PSI, BRIDGING SIZE AND SPACING SHALL BE AS DESIGNATED BY TRUSS MANUFACTURER UNLESS NOTES OTHERWISE. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS, ERECTION DRAWINGS AND DESIGN CALCULATIONS SEALED BY REGISTERED ENGINEER. SHOP DRAWINGS SHALL SHOW ANY SPECIAL DETAILS REQUIRED AT BEARING POINTS. ALL CONNECTORS SHALL HAVE CURRENT ICBO APPROVAL. THE MANUFACTURER SHALL DESIGN CONNECTION OF TRUSS REQUIRING PREFABRICATED HARDWARE HANGER OR OTHER. - FABRICATORTO SUBMIT SHOP DRAWINGS AND CALCULATIONS FOR ALL ELEMENTS OVER SIGNATURE AND SEAL OF FLORIDA ENGINEER (SPECIALTY ENGINEER). SPECIALTY ENGINEER MAY SUBMIT PREFERRED CONNECTION AND OTHER DETAILS IF DIFFERENT FROM SAME ON DRAWINGS FOR APPROVAL. -ALL WOOD MEMBERS IN CONTACT WITH CONCRETE AND/OR MASONRY TO BE PRESSURE TREATED. ALL WOOD EXPOSED TO THE WEATHER OR IN CONTACT WITH THE GROUND TO BE PRESSURE TREATED TO 0.80 CCA. - LAMINATED TIMBER ELEMENTS (BENTS, BEAMS, DECK, ETC., AND ANCILLARY ACCESSORIES, FASTENERS, ETC.: -FABRICATORTO SUBMIT SHOP DRAWINGS AND CALCULATIONS FOR ALL ELEMENTS OVER SIGNATURE AND SEAL OF FLORIDA ENGINEER (SPECIALTY ENGINEER) -SPECIALTY ENGINEER MAY SUBMIT CONNECTION DETAILS FOR BENTS AND BEAMS AND FASTENING MODE AND INTERVALS FOR DECK. (CONNECTIONS FOR BEAM -ENDS TO RESIST ROTATION.) - GLUE -LAMINATED BEAMS (GLULAM) SHALL BE DOUGLAS FIR COMBINATION 24F-V4 AT SIMPLE SPANS AND 24F- V8 AT CANTILEVER SPANS HAVING THE FOLLOWING MINIMUM PROPERTIES: Fb a 2,400 PSI, FV = 190 PSI, Fe (PERPENDICULAR) = 650 PSI, E = 1,800,000 PSI, FABRICATION AND HANDLING SHALL CONFORM TO THE LATEST AMERICAN INSTITUTE FOR TIMBER CONSTRUCTION (AITC) AND ASTM STANDARDS. BEAMS SHALL BEAR AN APPROPRIATE GRADE STAMP CLEARLY NOTING ITS DESIGN PROPERTIES. UNLESS CAMBER AND TOLERANCE IS SPECIFICALLY NOTED ON THE DRAWINGS, BEAMS SHALL BE MANUFACTURED WITH INDUSTRY STANDARD MINIMUM CAMBER OR UPWARD TO SPAN/200. ERECT WITH CROWN OR CAMBER UP. IN HEADER CONDITIONS BEAM BUILT INTO WALL CRIPPLE FRAMING ABOVE ( ) HEADER SHALL MAINTAIN CAMBER. HEADER BEAMS MAY HAVE ZERO CAMBER, PROVIDED CRIPPLE FRAMING ABOVE HEADER IS BUILT WITH MINIMUM CAMBER STATED ABOVE. - LAMINATED LUMBER AND "I" JOISTS AND RAFTERS SHALL BE INSTALLEDAS PER MANUFACTURER'S INSTRUCTIONS. - CONNECTORS BY SIMPSON OR APPROVED SIMILAR TO BE HDG OR ZMAX COATED IF UNEXPOSED TO WEATHER AND TO BE STAINLESS STEEL IF EXPOSED TO WEATHER UPON COMPLETION. SITE/LANDSCAPING: -THE IRRIGATION (IF USED) SYSTEM SHALL BE INSTALLED SUCH THAT NO WATER HITS THE BUILDING DURING OPERATION. - SLOPE GRADES AWAY FROM BUILDING ON ALL SIDES A MINIMUM OF 6" OVER 10% DOORS AND WINDOWS: - INSTALL GARAGE DOORS (INCLUDING BUCKS), EXTERIOR DOORS, AND WINDOWS AS PER MANUFACTURER'S SPECIFICATION/ PRODUCT APPROVAL. - PT 1x BUCK: ATTACH TO MASONRY/CONC W/ADHESIVE & RECESSED 3/16"x2" MIN TAPCON OR SD CASE HARD NAILS OR T NAILS @ 17/3" END. LIGHTING AND ELECTRICAL NOTES - PLANS ARE SCHEMATIC. EXACT LAYOUTAND SIZING OF CIRCUITS, RECEPTACLES, FIXTURES, AND EQUIPMENT, SHALL BE DETERMINED BY AN ELECTRICAL CONTRACTOR AND APPROVED BY THE ARCHITECT. - ALL OUTLETS TO BE ARC FAULTPROTECTED PER ARTICLE 210.12(B) 2008 NEC. - ALL 120V 15AAND 20A DWELLING UNIT RECEPTACLES SHALL BE LISTED TAMPER -RESISTANT TYPE. - PROVIDE GFIC AS DETERMINED BY NEC- 2008 ARTICLE 210-63. -ALL EXTERIOR OUTLETS TO HAVE GROUND FAULT INDICATOR BREAKERS AND WEATHER TIGHT PROTECTIVE COVER. - SMOKE ALARMS SHALL BE HARD WIRED, INTERCONNECTED, W/ BATTERY BACKUP PER FBC R314. - CARBON MONOXIDE ALARM TO BE INTEGRAL WITH SMOKE ALARM AND COMPLY WITH FBC R315 PLUMBING: - PLANS ARE SCHEMATIC, ACTUAL LOCATION, MATERIAL, AND SIZE OF PIPES, DRAINS, AND VENTS SHALL BE DETERMINED BY LICENSED PLUMBER AND APPROVED BY THE ARCHITECT. - NO PLUMBING REQUIREMENTS SHALL INTERRUPT THE STRUCTURAL INTEGRITY OF THE BUILDING. ROOF PENETRATIONS: - VERIFYALL REQUIRED ROOF PENETRATIONS FROM HVAC, PLUMBING, ELECTRICAL, AND OTHER DRAWINGS. PROVIDE ALL NECESSARY PENETRATIONS WITH REQUIRED ACCESSORIES TO PREVENT MOISTURE INTRUSION AND RETAIN STRUCTURAL STABILITY, IN ADDITION TO THOSE INDICATED ON THE ROOF PLAN. CONSULT ARCHITECT IF ROOF PLAN CONFLICTS WITH ANY REQUIRED ROOF PENETRATRATIONS. FIRE RATED UL FLOOR, WALL, & ROOF PENETRATIONS: - CONTRACTOR MUST USE SPECIFIC UNDERWRITER'S LABORITORIES DESIGN NUMBERED SYSTEMS FOR PENETRATING RATED WALLS, FLOORS, AND CEILINGS. ARCHITECTS DOCUMENTS MAY OR MAY NOT INDICATE CERTAIN SYSTEMS. CONTRACTOR TO FURNISH UL NUMBERS IF APPLICABLE. FLAME SPREAD INDEX & SMOKE DEVELOPED INDEX: FINISHES TO COMPLY WITH THE BELOW FIGURES AS PER FBC R302.9-302.10 INSULATION FLAME SPREAD: <25, INSULATION SMOKE DEVELOPED: <450 WALUCLG FLAME SPREAD: <200, WALUCLG SMOKE DEVELOPED: <450 / I \ CLIMATIC & GEOGRAPHIC DESIGN CRITERIA: WEATHERING: NEGLIGIBLE, TERMITE AREA: VERY HEAVY ABBREVIATIONS: AB ANCHOR BOLT AIC AIR CONDITIONER AHU AIR HANDLING UNIT AT ACOUSTICAL TILE B.M. BENCH MARK BO BY OWNER CLG CEILING CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONT CONTINUOUS CU CONDENSING UNIT CW COLD WATER CJ CONTROL (CONSTRUCTION) JOINT D DRYER DISP DISPOSAL DF DRINKING FOUNTAIN DTL DETAIL EXTG EXISTING EA EACH EL ELEVATION EW EACH WAY EWC ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER EXP EXPOSED EXT EXTERIOR EJ EXPANSION JOINT FD FIELD (FLOOR) DRAIN FIE FIRE EXTINGUISHER FF FINISH FLOOR FIN FINISH FLR FLOOR FP FIRE PROTECTION EPS EXPANDED POLYSTYRENE FTG FOOTING FT FOOT (OR FEET) GFI GROUND FAULT INDICATOR GSF GROSS SQUARE FEET (OR FOOT) GWH GAS WATER HEATER GWB GYPSUM WALL BOARD HB HOSE BIB HDG HOT DIPPED GALVANIZED HW HOT WATER IN INCH INT INTERIOR !ji�IL�➢�1 MAX MAXIMUM MFR MANUFACTURER MIN MINIMUM NIC NOT IN CONTRACT NTS NOT TO SCALE NSF NET SQUARE FEET (OR FOOT) LF LINEAL FOOT (OR FEET) OC ON CENTER OAS OR APPROVED SIMILAR P-L PROPERTY LINE PL PLATE PLY PLYWOOD PT PRESSURE TREATED PVC POLYVINYL CHLORIDE R RADIUS R/A RETURNAIR RCB REINFORCED CONCRETE BEAM RCC REINFORCED CONCRETE COLUMN RD ROOF DRAIN REF REFRIGERATOR REINF REINFORCING REQ REQUIRED RAN RIGHT-OF-WAY RTU ROOF TOP UNIT SIBS STYRENE BUTADIENE STYRENE SF SQUARE FOOT (OR FEET) SS STAINLESS STEEL STAG STAGGERED TBD TO BE DETERMINED THE TO MATCH EXISTING TOB TOP OF BEAM TOB TOP OF COLUMN TOS TOP OF SLAB TPO THERMO PLASTIC OLEFIN TYP TYPICAL LINO UNLESS NOTED OTHERWISE VB VAPOR BARRIER VTR VENT THRU ROOF W WASHER MACHINE WP WATERPROOF WD WOOD WWF WELDED WIRE FABRIC i Z 0 s o Lo 7 + r U fl) 0 -L ko 06 7 N tC ate) N r C C 0 W E V ® Z .� V ® C/) C) Z 0 /W� U V W Z V, W W �O V V Tf i general notE MAR 31, 20' S HH E EE A-2 r�co117 OR e�`CIS P. L/F6 E` AR97108 ism F1; SOG-MONO FOOTING 18"xCONTx18" SCHEDULE 0' 0" (2) 45 CONT BOTT ' F2 SOG-MONO 18"xCONTx18" -0'-4" (2) 115 CONT BOTT, CURB TO 0'-0" F3 COLUMN ISOLATED 36"x36"x12` 2' 0 (4) ifs EBOTT F4 SOG-MONO 18"xCONTx12" 0'-0" (2) 05 CONT BOTT F5 SOG- MONO 36' x36'X18" 0'-0" (4) 45 EW TOP/BOTT F6 SOG- MONO 1.8"xCONTx18" 0'-0 (2) 145 CONT TOP/BOTT, EXTEND 30" INTO F5 FZ I S ^ ,`RIOR 1 18"xCONTx18" 0'-0°' (2) 45 CONT B017 �a / F3 F3 DRIVEWAY & SIDEWALK AS PER SITE PLAN 4" SLAB ON GRADE F2 FOUNDATION / SLAB PLAN SCALE: 1/4"= T-0" - 4" SOG FEE: -0'-4" 9 3/8" 4�' SOG FE: -0'-4" FOUNDATION NOTES: -RECESS SGD & GARAGE Di -SEE GENERAL NOTES FOR SWR RECESS FFE: "0'-4" TYP REENTRANT CORNERBAR AS PER GEN NOTES F4 1/81/8" SLOPE F4 .SWR RECESS F2 FIFE: 44" c- TRIM TRUSS TAILS @ FLAT ROOF AS NEEDED MODIFIED BITUMEN OVER 5/8"CDX PLY OVER 2x12 RAFTER @ 24" OC DBL 2x10, GLUE & NAIL 12D @ 8" OC STAGGERED. EA RAFTER TO BEAM W/ SIMPSON H2.5T. BEAM TO CMU W/ (2) HETA20, 1x8 LIP, TO KEEP EDGE LEVEL, SHIM AS NEEDED FASCIA— HORIZ CYPRESS WOOD SIDING OVER 30# FELT OVER 1/2 COX PLY OVER 2x4 @16" OC SOFFIT- T&G TO MATCH FASCIA OVER 2x4 @16" OC THRESHOLDS 2"— VERIFY EXACT DIMENSIONS WITH SUPPLIER/MFR /EL LOCATIONS SOG 0'-0" F7 F7 SK F5 F5 F1 COLUMN BEYOND BEAR 2x12 ON WALL NOTCH +/- 1" AS NEEDED, SIMPSON HSTM16 BUILDING SECTION SCALE: 1/4"= V-0" TRAY CLG AS PER FRAMING PLAN LINTEL AS PER DNV SCHEDULE------.—Y 8-8 BEAM 1 ENTRY PORCH EAVE SCALE: 1-1/2"= V-0" 3.5:12 SLOPE TYP ROOF/ UNDERLAYMENT/ SHEATHING AS PER GENERAL SPECS - METAL DRIP EDGE TBD BY ROOFING CONTRATOR PE TRUSS AS PER FRAMING PLANS - INSULATION AS PER GENERAL SPECS TRUSS TO ALL BOND BEAMS W/ SIMPSON HETA 20 EA TRUSS, USE (2) @ MULTI PLY GIRDERS, USE DETAL20 FOR SINGLE PLY GIRDERS,USE � SIMPSON HSTM16 ON INSIDE FACE OF LINTEL FOR MISSED EMBEDED L ANCHORS. SEE FRAMING PLANS FOR OTHER CONDITIONS. ¢4 METAL DRIP OVER PT WOOD DRIP OVER 3/4"x5" PVC FASCIA TRIM- FASTEN TO SUBFASCIA W/ 2.5" TRIM SCREW (2) @ 24" OC OVER 2x4 SUBFASCIATO TRUSS ENDS W/ (2) #16d NAIL :+ EXTERIOR SOFFIT AS PER GENERAL SPECS r, TYP EAVE SCALE: 1-1/2"= V-0" WALLAS PER GENERAL SPECS WALL REF AS PER GENERAL SPECS. SPLICING AS PER GENERAL NOTES FOOTING AS PER FOUNDATION PLAN & FOOTING SCHEDLE— REINFORCEMENT AS PER FOOTING SCHEDULE GRADE AS PER SITE PLAN TYP WALL SECTION SCALE: V2"= V-0" <I> —W— mmrmwmmm AS PER BLDG SECT CLG AS PER GENERAL SPECS AND RCP MASONRY BOND BEAM & REF AS PER GENERALSPECS INTERIOR MONO Y _!.;q..... FOOTING CURB/ RECESS ....... . .... .W..—......... SOG/FILL/COMPCTION AS PER FOUNDATON PLAN AND GENERALNOTES 1zLINTEL AS PER WINDOW/DOOR SCHEDULE z NEW PT 1x BUCK @ JAMBS & HEAD, ATTACH TO MASONRY/CONC W/ADHESIVE & RECESSED 3/16"x2" MIN TAPCON OR 8D CASE HARD NAILS @ 12"/3" END, SAME FOR DOOR BUCKS WINDOW FRAME W/ FLANGE, ATTACH TO MASONRY/CONC AS PER MFR SPECS SILL AS PER WINDOW/DOOR SCHEDULE EXT INT TYP OPENING BUCK DETAIL SCALE: 1"= V-0" 0C14 C d O _cap s'�o O o O i LO 'O -- :3 + ..'.' N U) (n L- IV)Cp w M W Y_ M N ra C O (L6 w T V ® Z ._ � U pp@q V z .® 1% �0 W Z LLJ wz �® � ®V LU 1z d/ F- Z W O U W a 0 foundation plan MAR 31, 2018 SHEET A-3 m — 22"130"ATjfICAC�ESS — ®— — I I W1 LAIf DER — I� �rT T-I-T TT-TT_T_T-7-77 -- I e. I I I I;, ,,°,." 1 _ I I I I I I I i e ° ., '. bWPldr"a:°.ns.'f t " 'e I I I I I I ROOF FRAMING PLAN SCALE: 1/4"= 1'-0" ROOF PLAN SCALE: 1/8"= T-0" WRB SIDING PLY — SIDEWALL FLASHING 46 COPPER FLASH W/HEM PLY J UNDERLAYMENT- OVER & UNDER COPPER FLASH METALROOF SIDEWALL FLASHING SCALE 3"= T-0" FRAMING KEYNOTES: 1. 12" RECESS IN TRUSSES FOR TRAY CEILING 2. BEAM 1- CAST CRETE LINTEL 8F24-1 B/2T #6 FIELD 3. COLUMN- 16x16x8 CMU, 4 #5 VERT, #3 TIE @ 16" OC 4. BEARING WALLAS PER GEN SPECS FRAMING NOTES: �i� -ALL HIPS TO HAVE HIP TRUSSES FROM SUB -FASCIA TO GIRDER TRUSS -ALL WALLS SHOWN IN GREY ARE LOAD BEARING BELOW- BEAR TRUSSES ON ALL EXTERIOR WALLS Q Co -USE #6 FIELD BAR IN LIEU OF #5 FOR ALL OPENINGS WIDER THAN 12' AI c S=d � -a v .. (o CD -ao .— 0 p-o-- 'a¢0_ + N�(n fA 0 co� 0) �"'NN�n � ( �- N o C y O 00 "— 000�% N Mw Ir CD E V 0 Z ._ O V i U � N � C C) z O W U w Z W Z Vi NW w O V U H LU W 0 U W Q framing plan MAR 31, 2018 SHEET A-4 Z P AR97108 ?/ p. w Q� w z lip FLOOR PLAN NOTES: 1. INTERIOR DIMENSIONS ARE TO FINISH 2. EXTERIOR DIMENSIONS ARE TO STRUCTURE FLOOR PLAN KEYNOTES: 1. SHOWER VALVE LOCATION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ------ 36'-8" ......... . vie 23'-8" 8-41 F- HAND WAND HIGH WINDOW T P-1 �3 4 x .11'-4 1/8" T-5 9/16" 1 F F king size EDGE OF ROOF F I. SWR 01CLST SETBACK 5-10" 4- .1 — W13 N I ---------- — — — — — . . . .. .. ..... . . .... ... . ...... 2-8—x8--0 2'-7 lffl",_ 2-Ox8- D2 E3 F� — — — — — — — — — — — — — — — — — — 2'-10 7/8 GOVERED7c-3 FOYER LIVING ENTRY 2 CAR GARAGE COVERED PORCH zo C? i— — — — — -- — — — — — — - — — — — — — I DINING E Ll 2'71/16" 53/4" 9'-7 3/16" 2'-2" 4'-4 1M' 9-4" z is —0-1000 HWH c UTILITY rh 2'-7 3/8" - ------ ------ CLST 2-8x8-0 DW 4' 4' 4 7/8". 5. -OX8-0 KITCHEN �Mffl 9 2-W-0 En 6" T-3 1/8" —4'-113/4" 16-81/4" �6 LO 2-8x8-0 wall o00 %)ven/m.., i -------- pantry 00 04 0 AHU -8x8-0SK V ! 04DOORI] SHOWER! I SK c) w 1 SWR B.R.2 N B.R.3 HB r- - - - - - - - N C? CLST SWR 512- 11'-9 1/8" 1 V-9 1/2" DVY9 ---- --- - . ............. W i 7 6L, 0. r2'-2" 12' F— ID LOCAT. wi 1/EXT UNIT SIZE CMU R.O. (WxH) (WxH) 16-0x8-0 6-2x8-2 B.O. LINTEL 8-0 WINDOW SCHEDULE LINTEL CAST CRETE LINT[ L 8F8-113 TYPE .PANE PICTURE W/AWNING NOTES W2 1/EXT 4-Ox8-0 4-2x8-2 8-0 CASTCRETF LINT[ -8F8-1l3 5 PANE PICTURE W/AWNING TEMPERED W3 1/EXT 4-Ox2-0 4-2x2-1 8-0 CAST CRETE LINTt I,- L8F8- I B PICTURE TEMPERED W4 1/EXT 6-Ox2-0 6 2x2-1 8-0 CAST CRETE -IT, 8F8-113 F8_1 PICTURE W5 1/EXT S-8x5-0 5-10x5-1 8-0 CAST CRETE LINT L 8F8-1B HCRIZ SLIDER W6 1/EXT 5-8x5-0 5-10x5-1 8-0 CAST CRETE LINTI I- 8F8- 113 ITORIZ SLIDER EGRESSABLE W7 1/EXT 5-8x5-0 5-10x5-1 8-0 CAST CRETE LINTI L 8F8-113 jH0RiZ SLIDER EGRESSABLE W8 1/EXT 5-8x5-0 5-10x5-1 8-0 CAST CRETE 1 INTi I 8r8 16 LIORLZ SLIDER E TEMPERED 1/EXT 3-Ox2-0 3 2x2 11 8-0 CAST CRETE LINT[ .B P, t RE W10 11/EXT 3-Ox2-0 3-2x2-1 8 0 CAST CRETE I -I NTi I 8--IB PIG URE WIT 1/EXT 3-Ox2-0 3-2x2-1 8-0 ICAST CRETE LINJ, t I- 8F8-1 B PICTURE W12 1/EXT 3-Ox2-0 3-2x2-1 8-0 CAST r R ET E L I NT I - 8r'8-IB PICTURE W13 1/EXT 3-Ox2-0 3-2x2-1 0 CAST CRETE LINTi L 8F8-113 I N CTU RE W14 1/EXT 3-Ox2-0 3-2x2-1 8-0 CAST CRETE LINTL L SFS- t, F�17 5l 7r �W15 1/EXT -Ox2-0 3-2x2-1 8-0 CAST CRETE UNI L, 8F8-IB PICI­URL__L_ SHOP DRAWINGS PROVIDED TO CONTRACTOR BEFORE INSTALLATION CONTRACTOR TO VERIFY RO DIMENSIONS PRIOR TO MASONRY WORK MASONRY OPENINGS TO USE HiWind SILL BY CASTCRETE GLASS TO BE DOUBLE PANE WITH LOW-E GLASS TO BE IMPACT OR OPENING PROTECTION AS PER FBC-R4410.4 GLASS TO HAVE: IMPACT U-FACTOR!5 0.65, U-FACTOR:5 0.4, SHGC:5 0.25 FRAMES TO BE WHITE VINYL W/FINISH FLANGES FOR 3/4- WOOD BUCKS JALL WINDOWS TO HAVE INSECT SCREENS CMU R.O. ID LOCAT. SIZE (WxH) (WxH) D1 1/ EXT 3-0x8-0 5-6x8-2 DOOR SCHEDULE LINTEL CAST CRETE LINTEL SIR 8-16 77- �—' DESCRIPTION T§;WNG, 5 LITE GLASS PANEL, (2) 14" SlD ELITES D2 1/ EXT 2-8x8-0 2-8x8-2 CAST CRETE LINTEL 8RF8 113 S. SWING, 1 LITE GLASS PANEL D3 I/ EXT 15-2x8-0 15-482 CAST CRETE LINTEL 8F24-1.3/2T, #6 FIELD 4 PANEL SLIDER W1 FIXED ENDS D4 I/ EXT 6-Ox8-0 6-2x8-2 CAST CRETE LINTEL 8RF8-1 B 2 PANEL SLIDER D5 I/ EXT 2-8x8-0 2-10x8-2 CAST CRETE LI NTEL 8RF8-1B S. SWI W",J LITE GLASS PANEL D6 I I/ EXT 118-0x8-0 18-Ox8-0 CAST CRETE LINTEL 8F24-1B/1T OVERHEAD DOOR SHOP DRAWINGS PROVIDED TO CONTRACTOR BEFORE INSTALLATION CONTRACTOR TO VERIFY RO DIMENSIONS PRIOR TO MASONRY WORK GLASS TO BE DOUBLE PANE WITH LOW-E GLASS TO BE IMPACT OR OPENING PROTECTION AS PER FBC-R4410.4 GLASS TO HAVE: IMPACT U-FACTOR:5 0.65, U-FACTOR 5 0.4, SHGC!5 0.25 JALL FRAMES TO BE VINYL ISEE FLOOR PLAN FOR SWING DIRECTION WALL LEGEND ID DESCRIPTION SPECS REINFORCED CMU WALL SEE GENERAL SPECIFICATIONS ON A-1 REINFORCED CMU COLUMN SEE COLUMN SCHEDULE NON LOAD BEARING FRAME WALL SEE GENERAL SPECIFICATIONS ON A-1 LOAD BEARING 2x6 WALL SEE GENERAL SPECIFICATIONS ON A-1 I7777== LOAD BEARING 2x4 WALL SEE GENERAL SPECIFICATIONS ON A-1 U C N 0 CD 0 c 0 Lo 16 :3 + U) a CN a) U) U) 0 m :E (1) 06 U) U). 0 c 0 w- QQ E 0 Z W�0 4-0 0 C) C%ft00 z .0 Lu L) z w W z Lu w 0 z w 0 w floor plan MAR 31, 2018 SHEET A-5 FLOOR PLAN SCALE: 1/4"= 1'-0" F CIS P. L/,q ".7 1 AR97108 POWER PLAN LEGEND Pt 110V DUPLEX RECEPTACLE P2 111 GFCI DUPLEX RECEPTACLE P3 120V RECEPTACLE recessed for tv P4 220V RECEPTACLE _ P5 110V DUPLEX RECEPTACLE w/ water protected box L1 LED RECESSED CAN LIGHT L2 FLUSH MOUNT CLG LIGHT L3 FLUSH LED STRIP LIGHT L4 VANITY WALL LIGHT L5 SHOP LIGHT L6 CHANDELIER LIGHT L7 PENDANT LIGHT L8 UNDER CABINET LIGHT L9 EXTERIOR WALL SCONCE L10 WALL MOUNT READING LIGHT 1-11 EXTERIOR MOTION DETECTOR LIGHT L12 FLUSH MOUNT CLG LIGHT- wet location S LIGHT SWITCH EX EXHAUST FAN EXL EXHAUST FAN WITH LIGHT FL FAN/ LIGHT COMBO JB JUNCTION BOX SD SMOKE DETECTOR- INTERCONNECTED, HARDWIRED W/BATTERY SA AC SUPPLYAIR CEILING GRILLE _ RA AC RETURN AIR CEILING GRILLE EX EXHAUST FAN CU I I , I / P1 ,'W 2 ai- T. fat P2 " d..mr SD a r r r / r / r / r / r ' i 1 a r/ n r/ a r/ I HWH p-dryor a -:P1 /® p-ref: P2 ' f p I II ` P1 Pi a. I HEF T Ar garage door I SD motor I I I I '� w II I I P2 I t , EU I � I f MDP EXL ➢9i *+/yk^ St° METER Ell La / / / / I / Y / r5' EE N \ \ \ \ SD ,\' \ 13 s 1 8 � \ ) \ SD \ o IM E Fil F& 0 N NEW UNDERGROUND METER FOOTING STEEL SIZE BY ELECTRICAL CONTRACTOR ELECTRICAL RISER DIAGRAM SCALE N T t 2017 Dwelling Unit Electric Service 8r Feeder Load Calculator 220.12 General Lighting Load 3 va/flz of floor area, including unused space adaptable for future use. Floor Area = 2201 6,600 va Basement Floor Area = ft° va 220.52(A) Small Applllnce Load 1500 va for each 20 amp branch circuit required per 210,1(C)(1) In EACH kitchen, pantry, breakfast room, dining room, or similar areas. # of Small Appliance Branch Circuits1500 va= 3,000 va 220.52(B) Laundry Load # of Laundry Branch Circuits =0. 1500 va = 1,500 va Total General Lighting & Appliance Load= 11,100 va 220.42 Lighting Load Feeder Demand Factors First 3000 or less at,00% 3,000 va From 3001to 120,000 at 35% 2,835 va Remainder over,2o,o00 at 25% va Total Lighting Demand Load=- :.. 5,835 va 220.54 Electric Clothes Dryers Qty Electric Dryer#1 5.00 kw 5,000 w Qt o y Electric Dryer f kw w 220.55 Electric Cooking -Ranges, Stove Tops and Wall Ovens Qty kw Qty kw Qty ]kw Electric Cooking Demand Load= 11,600' w 220.51 Fixed Electric Space Heating Loads or Air Conditioning Load: Fixed Electric Space Heat#a 10A kw AC#nlGeo 16 SEER 3Too 3.6 kva Fixed Electric Space Heat it2 - kw AC#216eo kva Fixed Electric Space Heat #3 kw AC#3/Geo kva Fixed Electric Space Heat #y kw AC#4/Geo - kva Fixed Electric Space Heat #5 kw AC#5/Geo kva Total Heat B, AC Load = 13,820-va 220.14 Appliance load —Dwelling Units Qty Description va(watts) Qtv Description valwatts) 1 Well Oven Nameplate 4.50 1 s Electric Nameplate 11.00 0 1 Central Furnace 1,200 1 Dishwasher 11200 1 Refrigerator 1,440, 1 Microwave 1,580: 1 Range Hood 240 3 Vent Fan 300: 4 Paddle Fan 36o '. 1 wine Comer 360 '1 D 0 0 0 0 Total Connected Appliance Loatl= 6,680 va 220.53 Appliance load --Dwelling Units Total Appliance Demand Load - :. 5,010 va 220.50 Motor Loads @ 120 Volts Qty Description va(watts) Description v we 1 3I4BpPool{Spa Pump, 563 11/2hpGarpage Dispos ! $75 z i/2hpGar{DoorOpener 375 d Total Motor Load = 1,688 va 430.24 Several Motors or a Motors) and Other Load(s) 25 %of Largest Motor Load = 141 va Total Motor Demand Load = 1.'m va TOTAL CALCULATED DEMAND LOAD In Volt-amperes = 42,894 va TOTAL CALCULATED DEMAND LOAD In AMPS @120/240V 1pli= 179 amps EXISTING SERVICE SIZE NEW AMPS MINIMUM SERVICE SIZE : 200 AMPS ACE SIZE REQUESTED= ( 200amps Note: Electrical contractorto verify accuracy and completeness of load calculation A L O .� O p w+ N(nULLI ) Ny O :r'e (h � � W � �\ f.7 �r~` vJ N W O_ Z ._ O V �NN vI LLL '0 V Z O U U w Z WZ W rO 'V+ /V LL f— Z W O U W Q ❑ power/RCP MAR 31, 2018 SHEET A-6 r(t/(G Vr• r(O� P. LIEe��'.9 ,. AR97108 , POWER PLAN SCALE: 3/16"= V-0" REFLECTED CEILING/ MECHANICAL FLAN SCALE: 3/1l V-0" z V) W HVAC LEGEND -4--- SIDEWALL SUPPLY- FLEX DUCT ♦---- CEILING SUPPY- FLEX DUCT SUPPLY TRUNK DUCT EXHAUST DUCT TO EXTER€OR- SOFFIT — `- SIDEWALL RETURN- FLEX DUCT --- CEILING RE! URN- FLEX DUCT RET URN TRUNK DUCT HOR4NTAL. CYPRE.®IQLN•� WEST ELEVATION SCALE: 3/16"= T-0" tf ppp n 1 k At L id ... COVEREft T" "PM"e IJVIf>dr°x ENTRY � --------------- 5 r1YPdBi •. -x _ ____ ___ __ --0 U TKIt Y lzrIwt I � I � • S 3. t c � I _ I I i C1,IST , R Lu"�4ib:kdivS = �litl�l$�@uPl€e6PdiI9198P8S�1%� 8W6S&°.6 � ••nk'4 1 I EAST ELEVATION SCALE: 3/16"= VI SOUTH ELEVATION SCALE: 3/16"= 1'-0" Y_ Q CD O Ln p • .�++�N�Cn L- fA p cr) � �1N�(n into C O ie ca U t: 0I yN T E S Z .® vO L U AW I- _ U z O W U z IJ.1 z ® V Lu/ w r® CV1J A z W O U W Q ❑ elevations MAR 31, 2018 SHEET A-7 / `?.- %s P. Lige��.9 AR97108 F��sr�............ :a��jU' HVAC/ MECHANICAL PLAN SCALE: 3/16"= VI NORTH ELEVATION SCALE: 3/16"= VI HVAC LE SEND �4--- SIDEN ,LL SUPPLY- FLEX DUCT ♦---- CEILI� I SUPPY- FLEX DUCT ® SUPPI 'TRUNK DUCT •----- EXHAI 'T DUCT TO EXTERIOR- SOFFIT ®--- SIDEN ,LL RETURN- FLEX DUCT ♦---- CEILIN i RETURN- FLEX DUCT ® RETUI J TRUNK DUCT I COVERIE ENTRY y 2 CAR GARAGE SWR I I FOYER LIVING I 1 loX lac b I I .---���--------------------------- I I Ito' o---------------- UTILITY a c �- CLST - / '/ ` �l — '/ '.! 2»I�n�r�J2% pantry ---0 N •i�0OUTDOOR g m mi Oylc i GA O °I��' A- A 06. 46.ktzo�YA�L EMS fEl WEST ELEVATION SCALE: 3/16"= T-0" EAST ELEVATION SCALE: 3/16":= T-0" SOUTH ELEVATION SCALE: 3/16"= T-0" a 120 N P 0 O V In Q .6 'a a `r +�++—NU) yC!= W a {7 P U) V! o N a+ _ d E V O d _ z .O v U z e,;i W® z w W z w 0 z Z W U 0 elevations MAR 10, 2018 SHEET A=7 P. L/fed '•."F 1 P_ J-ti HVAC/ MECK NICAL PLAN SCALE: 3/16"= 1'-0" NORTH ELEVATION SCALE: 3/16" = 1'-0" "i ST, Lucie County, Per =LIFE SAFETY WARNING This symbol identifies Life Safety Warnings that should be read and given special attention to all persons installing trusses. SPACING NOTE All trusses are to be set 2'-0" on center except as noted. MULTIPLE PLY TRUSSES MUST BE FASTENED TOGETHER PER ENGINEERING BEFORE SETTING. REFER TO ENGINEERING DRAWING w TO DETERMINE IF MULTIPLE PLY. DON'T LIFT TRUSSES WITH SPANS LONGER THAN 30' BY THE PEAK. CONSULT BCSI 30' Span or less A 60 degrees or less Tag line 112 span -- Tag line ' � APProx 2/3 to —� approx. __. a 1/2 of Span. REFER TO BCSI Truss must be set this way if crane is used. Truss is an example, your truss may not match. Insist crane operator sets truss this way. REFER TO BCSI Truss must be set this way if crane is used. Truss is an example, your truss may not match. Insist crane operator sets truss this way. All load bearing walls, headers, beams, & lintels must be in place at indicated height before trusses IANare installed. ,, AIR HANDLER NOTE Unless noted elsewhere on this layout, these trusses are not designed for air handlers in the roof or for any other A/C requirer,.lents. This may be in conflict with building code and A/C Design requirements. Consult with Building Department and A/C Contractor. ! a... WARNING !\ The size of, these trusses makes it necessary that they a set by a profeesional builder familiar*with"and experienced in the problems and dangers of setting large span trusses. Th*bITIlder and erector should consult with an engineer licensed in Florida specializing in wood roof trusses about the safe erection of these trusses. The engineer should be at ttygfjob site when trusses are erected to provide supervision and advice. 'SEAT PLATES BY CHAMBERS TRUSS III CA I Hatch Legend CEILING HEIGHT @ 11' BRIG WALL @ 10' REPRESENTS A HANGER HANGER SCHEDULE USE HUS26 FOR 2X4, SUH46 FOR 4X2 EXCEPT AS SHOWN CARRIED CARRYING ! HANGER ID FASTENER FOR FASTENER FOR TRUSS TRUSS CARRIED TRUSS CARRYING TRUSS Aw *Please refer to Standard Engineering package for general instuction on installing hangers 10d=0.148" x 3" 16d=0.162" x 3 1/2" NOTES: *ALL BEAMS BY OTHERS. *FLAT ROOF FRAMING BYOTHERS. *CEILINGS TO BE UNDER FRAME BY BUILDER. *INTERNAL LOAD BEARING WALLS REQUIRED BY TRUSSES AS SHOWN ON THIS LAYOi *PLEASE VERIFY ALL DIMENSIONS, BEAM HEIGHTS, HEEL CONDITION & ROOF PITCH. A Do not stand on trus METAL ROOFS S until they are braced per BCSI & properly nailed to straps and hangers !! JW IMPERFECTIONS. SPECIAL INSTALLATION CARE MUST BE TAKEN- 3.5r- 2-00-00 � PLUMB CUT END 2X4 TOP CHORD WALL HEIGHT @10' END DETAIL: TYPICAL r LVIYIU l u 1 CIVLI 2X4 TOP CHORD WALL HEIGHT @ 10' END DFTAII • rOFFFR CORNER DETAIL v+salsNas hqT slxrxx wh1 cup1Y FABRICATION AGREEMENT TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED 'he undersigned admowk0ges and agrees: 1. Trusses win be made in strict accordance with this truss placement diagram layout which is the sole authority fc letermining successful fabrication of the trusses. 2. An dimensions in this layout have been verified by the undersigned. 3. Unless written notice is provided by certified mail to Chambers Truss within ten (10) days of delivery thl ndersigned agrees that no badccharges will be alknred. In the event such written notice is famished Chambers Tnls hall have three (3) business days in which to begin repairs required, or to substitute other trusses. at Chambers option dter 10 days of delivery remedy will be according to Florida stable 558. 4. The undersigned admowleciges receipt of 'BCSI' summary sheet by TPI & WTCA 5. Delivery is to job site. It's the buyers responsibility to make the job site suitable for delivery. Chambers Truss ha to sole authority to determine the suitability of the job site or a portion of the job site for dernwzy. Chambers Truss wi e responsible for dump delivery only. The buyer's responsible for additional delivery expenses it Chambers Truss ha ) redefiver because job site is not prepared for delivery or buyer is not prepared for delivery of busses. Buller i nponsible to Chambers Truss for towing costs due to site conditions. 6. Price as shown in paragraph 7 below is subject to changed any changes are made in this layout. A $50 per hou .e for revisions may be charged by Chambers Truss. 7. This is a PURCHASE ORDER to Chambers Truss of the sum agreed to, or it no agreement a reasonable price (voice will be made on delivery and paid within terms of net on delivery. Invoice may be made at scheduled date o elivery it buyer cannot accept delivery of fabricated trusses. The undersigned agrees to pay Chambers Tms lasonable attorneys fee for collections in event of payment not timely made. 1-1f2 % per month service charge wig br dded for all sums not paid within terms. 8. Signature or initials anywhere on this sheet constitutes agreement to all terms herein. 9. In Consideration of Chambers Truss extending credit for this material the undersigned unconditionally guarantee! ayment when due of any and all indebtedness owed to Chambers Thus by any entity receiving material and Inc ndersigned agrees to pay such indebtedness Including attorneys fees, it default in payment for material be made by the zipient. 10. In the event of any litigation concerning this agreement the item furnished hereunder or payments fefared lic erem, the parties agree that the sole venue for any such action will be Saint Lucie County, Florida. 11. Design responsibilities are per —National Standard And Recommended Guidelines On Responsibilities Fa Dnstruction Using Metal Plate Connected Wood Trusses ANSUTPUWTCA 4 - 2002'"' 12. Warranty is per Chambers Truss Warranty attached. A spreader bar may be required per "BCSI" to prevent injury & damage. Multiple ply trusses must be fastened together per engineering before they are set, failure to do so can result in roof collapse. Temporary and permanent bracing are required and can save life and property and is the responsibility of the truss erector. Study the contents of the information packet included on delivery before setting trusses. Trusses must be set and braced per design to prevent injury & damage. Trusses must be s®s®lumb and square Do not set bunks or stack of plywood, roofing material or any other concentrated loads on trusses, this can cause collapse. DO NOT INSTALL TRUSSES USING THIS USE PLAN DELIVERED WITH TRUSSES TO SET TRUSSES CHAMBERS TRUSS INC ..�'.►i► 3105-OFeander Avenue Fort Pierce, Florida 34982.6423 800-551-5932 Fort Pierce 772-465.2012 Fax 772-465.8711 Vero Beach 772-569-2012 Stuart T72-286-3302 Web Site: CHAMBERSTRUSS.COM Email: MAIL@CHAMBERSTRUSS.COM LOADINGDESIGN CRITERIA REDIIcnelE DESIGN CRITERIA PER CODE SUCH AS SBC oe.6.1 18 County Saint Lucie County Building Department Saint Lucie County Wind Design Criteria ASCE 2010 Wind Design Method MWFRS(Directional)/C-C hybrid Wind ASCE 7-10 Roofing Material Metal Loading in PSF _ Roof R.D.L. Floor Top Chord Live 20 0 Top Chord Dead 15 4.2 0 Bottom Chord Live `10-Non Conccurent 0 Bottom Chord Dead 10 3 0 Total Load 55 72 0 Duration Factor 1.25 0 Wind Speed 170mph Top Chord C.B. Sheathing by builder Bottom Chord C.B. Sheathing by builder Highest Mean Height 15' Building Type Enclosed Building Category If: Non Restrictive Exposure Category C>Open Terrain with scattered obstructions Miles from Ocean 5 Conforms to Florida Building Code 2017 R.D.L.=Restraining Dead Load C.B =Continuous Bracing Verify DESIGN CRITERIA shown above with the building department and your engineer. Design Criteria is the responsibility of the Building Designer and/or Engineer of Record Chambers Truss Inc. Drawing Name: 75033 SCALE: 1/4" = 1/-011 128 total trusses, 54 unique designs Designer: BLW Reviewed by: — Date: 04/16/18 Revised 07/18/18 FOR Group One Construction DESCRIPTION: RICCIO �u.. �` J Page 1 of 1 CUSTOMER INITIALS EACH PAGE 75033