Loading...
HomeMy WebLinkAboutHVAC LOADSRhvac r Residential & Light Commercial HVAC Loads i Elite Software Development, lnc. Green Design_Construcfion & De re Casa EnT ce Okeechobee FL­�3'4972 Page 2 -Ro iObt•RWor -: :.. Project i itie: Designed By: Project Date: Client Name: Client Address: Client City: Company Name: Company Representative: Company Address: Company City: Company Phone: Company Fax: Company E-Mail Address: Company Website: Casa En Trece David Wolter Friday, August.4, 2017 Scott Britton 434 SE Naranja Ave Port St Lucie Green Design Construction & David Wolter 4459 SE Kubin Ave Stuart, Florida, 34997 (863) 467-1111 (863) 582-9574 David@GDCFLORIDA.COM W W W.GDCFLORI DA.COM Reference City: Fort Pierce, Florida Building Orientation: Front do r faces Northwest Daily Temperature Range: Medium Latitude: 27 . Degrees Elevation: 25 ft. Altitude Factor: 0.999 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 42 39.4 n/a n/a 70 n/a Summer: 90 78 59% .55% 75 55 Gheck Figures �,1�.:. �d ;.�"„ �, �� I ,. , ... Total Building Supply CFM: 1,577 CFM Per Square ft.: 0.641 Square ft. of Room Area: 2,461 Square ft. Per Ton: 646 Volume (W): 25,095 Buildin : Loads= Total Heating Required Including Ventilation Air: 35,232 Btuh 35.232 MBH Total Sensible Gain: 36,6i81 Btuh 80 % Total Latent Gain: 9033 Btuh 20 % Total Cooling Required Including Ventilation Air: 45,il13 Btuh 8.81 Tons (Based On Sensible + Latent) Notes ' Rhvac is an ACCA approved Manual J and Manual D.computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. \\ts3400d600\GDCD, ...\Britton Residence.rh9 I Wednesday, January 10, 2018, 5:30 PM Rhvac - Residential .& LightCommercialHVAC Loads Elite Software Development, inc: Green•Design Construction & De ® s Casa En. Trece Okeechobee, FL 34972 Pa e 4 FDuci.Size'.Prev-:iew Room or source Minimu . Maximu Rough Desig S Du Duc Htg Clg Act. Duct Duct Name Veloci Veloci Fact L/10 Loss Ve�oci Lengt Flow Flow Flow Size System 1 Supply Runouts Zone 1 1-Master Bedroom (SR-250, TMDD 450 600 0.01 0.08 0.0178E 452.8 3 82® 241 7 SR-260) 450 600 0.01 0.08 0.02587 452.8 10.5 7 2-Master WIC 1 (SR-280) TMDD 450 600 0.0 0.08 0.00091 80.2 5.5 1 ®I 7 4 3-Master WIC 2 (SR-240) TMDD 450 600 0.0 0.08 0.00811 217.7 8.5 12®I 19 4 4MasterBath (SR-230) TMDD 450 600 0.0 0.08 0.05103 483.8 10.5 40®I 95 6 5-Foyer (SR-220) TMDD 450 600 0.0 0.08 0.05314 527.1 3.6 24®I 46 4 450 600 0.01 0.08 0.04894 501.4 8.5 7 6-Living lKitchen And Dining TMDD 450 600 0.01 0.08 0.06002 501.4 17 78 402 7 (SR-180, SR-190, SR-210) 450 600 0.0 0.08 0.04373 501.4 4.5 7 7-Bedroom 1 (SR-200) TMDD 450 600 0.0 0.08 0.0466E 539.9 1.5 21®I 106 6 8-Bedroom 2 (SR-110) TMDD 450 600 0.0 0.08 0.04842 519.5 4.5 29MI 102 6 9-In-Law Suite (SR-150, SR-1E TMDD 450 600 0.01 0.08 0.02387 552.9 1.5 69® 386 8 450 600 0.0 0.08 0.0392e 552.9 8 8 10-In-LawWIC (SR-270) TMDD 450 600 0.0 0.08 0.00879 171.9 8.5 7®I 15 4 11-In-Law Bath (SR-130) TMDD 450 600 0.011 0.08 0.0340E 396 8 14®I 54 5 12-Bath 1 (SR-120) TMDD 450 600 0.0 0.08 0.02632 389.6 2 8®I 34 4 13-Utility (SR-1 00) TMDD 450 600 0.01 0.08 0.05853 506 7.5 22®I 69 5 Other Ducts in System 1 Supply Main Trunk (ST-100) TMDD 700 700 0.0013 0.08 02436£ 688.1 24 408� 1,577 15x2 ST-110 TMDD 700 900 0.003 0.08 0.00585 568.6 3 328 1,303 15x2 ST-120 TMDD 700 900 0.0013 0.08 0.03814 733.6 17 258® 917 120 ST-130 TMDD 700 900 0.00I3 0.08 0.03841 724 11 185®I 543 9x1 ST-140 TMDD 600 700 0.0, 0.08 0.0901E 606.6 15 95®I 266 9 ST-150 TMDD 600 700 0.01 0.08 0.07083 584.9 14 70®I 386 11 RT-100 TMDD 0 0 0.003 0.08 0.10761 811 21 1,57 1,577 14x2 RT-110 TMDD 0 0 0.01 0.08 0.08422 579.9 25 914® 914 1 RR-100 TMDD 0 0 0.0I1 0.08 0.01367 381,.7 1.5 0®I 102 7 RR-110 TMDD 0 0 0.01 0.08 0.04134 579.3 6 0®I 455 1 RR-130 TMDD 0 0 0.011 0.08 0.0604E 597.8 8 0®I 551 13 RR140 TMDD 0 0 0.01 0.08 0.04884 550 19 0®I 363 11 RR-150 TMDD 0 0 0.0�1 0.08 0.02127 396.6 9.417 0 106 7 i Summary System 1 Heating Flow: 409 Design Friction Rate: 0.075 TEL Return: 374. Cooling Flow: 1577 Total Cumulative SP Loss: 0.694 TEL Supply: 312 Fan ESP: 0.694 Device SP Loss: 0.18 TEL Total: 686. Fan SP Available: 0.514 Return Loss Added to Supply: 0.252 I \\ts3400d600\GDCD ...\Britton Residence.rh9 I Wednesday, January 10, 2018, 5:30 PM I Rhvac Residential & Light Commercial HVAC Loads Elite Software Development, Inc: Green'Design Construction & De .. _ Casa,En,Trece _. _,o. ..., T Okeechobee, FL 34972 Page 5 S .stem .1 '- SVstem -1.: =.:Ade ua:te Exposure � " � Div . ersit ::Test.:..: :. . Test For Adequate xposure Diversity 60,000 50,000 40,000 m e 30,000 c C7 a� 20,000 42.1% Diff. from Avg. (1,149 Btuh Excursion) 10,000 0 8 am 9 am 10 am 11 am 12 pm 1 pm 2 pm 3 pm 4 pm 5 pm 6 pm 7 pm / Average Glass / 1.3 x Average / Hourly Glass Gain / Hourly Total Net Sensible Gain Glass Gain Gain Over 12 Hours AED Calculation-Sbmrh ; g "In a. . --- SYSTEM DOES NOT HAVE ADEQUATE EXPOSURE DIVERSITY. --- System is on NE, SE, SW, NW rosette. Peak load exceeds 12-hour average load by 42.1 %. AED Excursion (amount by which peak exceeds 1.3 x average): 1,149 Btuh - - - - ------------- --------------------------------------- - - ------------------------------------------------------------------------------------------------------------------------ - - - Definition: A system has adequate exposure diversity if the peak -hour glass load for the entire conditioned space does not exceed the average glass load for the entire conditioned space' by more than 30 percent. (System Concept Warning for excursion greater than 1.3 x baseline and less than 1.5 x baseline) This application has glass areas that produced relatively large heat gains for part of the day. Variable air volume devices may be required to overcome spikes in solar gain for one or more rooms. A zoned system may be required, or some rooms may require zone control (provided by individual, motorized, thermostatically controlled dampers). \\ts3400d600\GDCD ...\Britton Residence.rh9 I - Wednesday, January 10, 2018,.5:30 PM i Rhvacr Residential & Light Commercial HVAC Loads `: Elite Software Development, Inc:_ Green Design,Constru'ction & De .. _. _ _ , .. Casa En Trece .. ._ A _ Okeechobee, FL Wf - Pa e 6 T6tal:•Buildit)•.Sui 'mar . Loads-.- Areal �De"scn tibn,1�, u:.. s �, _*:: s �,Quan_ Sen�� Loss M. Lat" Sen T' Gain,.;_=Gain ;,• : Gain; SH700: Glazing -Alum, W/ NO GRID, AIR FILL, CLEAR, 186.4 3,392 0 3,615 3,615 outdoor insect screen with 50% coverage, u-value , 0.65, SHGC 0.25 - FD750: Glazing -Alum, , CLEAR, W/ AIR FILL, Impact, u- 29 633 0 597 597 value 0.78, SHGC 0.25 PW720: Glazing -Alum, W/ NO GRID, AIR FILL, CLEAR, 4 84 0 114 114 u-value 0.75, SHGC 0.25 HR710: Glazing=Alum, W/ NO GRID, AIR FILL, CLEAR, 56.4 1,027 0 .1,374 1,374 - outdoor insect screen with 50% coverage, u-value 0.65, SHGC 0.25 FD750: Glazing -Alum, , CLEAR, W/AIR FILL, Impact, in 90.2 1,970 0 1,439 1,439 partition wall, u value 0.78, SHGC 0.25 SGD770: Glazing=Alum, W/ NO GRID, AIR FILL, CLEAR, 132 2,773 0 1,485 1,485 IMPACT, in partition -wall, u-value 0.75, SHGC 0.25 - 11 N: Door -Metal - Polystyrene Core - 28.3 277 0 317 317 13A-5ocs: Wall -Block, board insulation only, R-5 board 1453.9 5,090 0. 2,780 2,780 insulation, open core, siding finish 13A-5ocs: Part -Block, board insulation only, R-5 board 279 977 0 484 484 insulation, open core, siding finish 12B-Obm: Part -Frame, R-11 insulation in 2 x 4 stud 167.7 526 0 601 601 cavity, no board insulation, brick finish, metal studs. 16A-0: Partition Roof/Ceiling (STD=4,-WTD=4)-Under 2417.6 3,945 0 3,945 3,945 Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Unvented Attic, No . Radiant Barrier, Any Roofing Material, Any Roof Color, R-0 insulation 16C-30: Partition Roof/Ceiling (STD=4, WTD=4)-Under 162 21 0 21 21 Attic with Insulation on Attic. Floor (also use, for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, White or Light Color Shingles, Any Wood Shake, Light Metal, Tar and Gravel or Membrane, R-30 insulation 22A-ph: Floor -Slab on grade, No edge, insulation, no - 250 9,505 0 0 0 insulation below floor, any floor cover, passive, heavy moist. soil Subtotals for structure: 36,220 0 16,772 16,772 People: 6 1,200 1,380 2,580 Equipment: 2,905 . 11,828 14,733 Lighting: 985 3,359 31359 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 40, Summer CFM: 10 1,227 372 165 537 Ventilation: Winter CFM: 123, Summer CFM: 123 3,785 4,556 2,028 6,583 Exhaust: Winter CFM: 100, Summer CFM: 100 AED Excursion: 0 0 1,149 1,149 Total Building Load Totals: 35,232 9,033 36,681 45,713 Check4Fi d uresf �. Total Building Supply CFM: 1,577 CFM Per Square ft.: 0.641 Square ft. of Room Area: 2,461 Square ft. Per Ton: 646 Volume (ft3): 25,095 :y� w b y +. sky., 'e 4 � ' i w ?gym =- •1 Ma au Total Heating Required Including Ventilation Air: 35,232 Btuh 35.232 MBH Total Sensible Gain: 36,681 Btuh 80 % Total Latent Gain: 9,033 Btuh 20 % Total Cooling Required Including Ventilation Air: 45,713 Btuh 3.81 Tons (Based On Sensible + Latent) Notes - . \\ts3400d6OO\GDCD ...\Britton Residence.rh9 I Wednesday, January 10, 2018, 5.30 PM I Rhvac - Residential .& Light Commercial HVAC Loads, Elite Software Development; Inc: Green' Design Construction &" De. _ Casa En Trece Okeechobee, FL,34972 i c Pa e7 :Total:8uilding Summar .Loads (cont.d . NOtES, Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. \\ts3400d600\GDCD ...\Britton Residence.rh9 Wednesday, January 10, 2018, 5:30 PM Rhvac r Residential &.Light Commercial HVAC Loads Elite Software bevelopmen#, Inc6. Green Design Construction &: De . _ Casa En Trece Okeechobee, FL 34972 . Pa e 8 S stem 1 S ; sterri.�l;Sumr►�a; Loads:.:: Corriponent'`'f � K. Area , Send , �L�atfi g "'MS 6`6r" g Total p Descri'�tion . .,. x�a �� fi ., Quan, _ : Loss-• ,Ga_in G_aum Gain.: SH700: Glazing -Alum,. W/ NO GRID, AIR FILL, CLEAR, 186.4 3,392 0 3,615 3,615 outdoor, insect screen with 50% coverage, u-value 0.65, SHGC 0.25 FD750: Glazing -Alum, , CLEAR, W/ AIR FILL, Impact, u- 29 633 0 597 597 value 0.78, SHGC 0.25 PW720: Glazing -Alum, W/ NO GRID, AIR FILL, CLEAR, 4 84 0 114 114, u-value 0.75, SHGC 0.25 HR710: Glazing -Alum, W/ NO GRID, AIR.FILL, CLEAR,,. 56.4 1,027 0 1,374 1,374 outdoor insect screen with 50% coverage, u-value 0.65, SHGC 0.25 FD750: Glazing -Alum, , CLEAR, W/ AIR FILL, Impact, in 90.2 1,970 0 1,439 1,436 partition wall, u-value 0.78, SHGC 0.25 SGD770: Glazing -Alum, W/ NO GRID, AIR FILL, CLEAR, 132 2,773 0 1,485 1,485 IMPACT, in partition wall, u-value 0.75, SHGC 0.25 11 N: Door -Metal - Polystyrene Core 28.3 277 0 317 317 13A-5ocs: Wall -Block, board insulation only, R-5 board 1453.9 5,090 0 2,780 2,780 insulation, open core, siding finish 13A-5ocs: Part -Block, board insulation only, R-5 board 279 977 0 484 484 insulation, open core, siding finish 12B-Obm: Part -Frame, R-11 insulation in 2 is 4 stud 167.7 526 0 601 601 cavity, no board insulation, brick finish, metal studs 16A-0: Partition Roof/Ceiling (STD=4, WTD=4)-Under 2417.6 3,945 0 3,945 3;945 Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Unvented Attic, No Radiant Barrier, Any Roofing Material, Any Roof Color, R-0 insulation 16C-30: Partition Roof/Ceiling (STD=4, WTD=4)-Under 162 21 0 21 21 Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No . Radiant Barrier, White or Light Color Shingles, Any Wood Shake, Light Metal; Tar. and Gravel or Membrane, R-30 insulation 22A-ph: Floor -Slab on grade, No edge insulation, no 250 9,505 0 0 0 insulation below floor, any floor cover, passive, heavy moist soil Subtotals for structure: 30,220 0 16,772 16,772 People: 6 1,200 1,380 2,580 Equipment: 2,905 11,828 14,733 Lighting: 985 3,859 3,359 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 40, Summer CFM: 1.0 1,227 372 165 537 Ventilation: Winter CFM: 123, Summer CFM: 123 3,785 4,556 2,028 6,583 Exhaust: Winter CFM: 100, Summer CFM: 100 AED Excursion: 1 0 0 1,149 1,149 System 1 System 1 Load Totals: 35,232 9,033 36,681 45,713 Check,Fi ores _ .. Supply CFM: 1,577 CFM Per Square ft.: 0.641 Square ft. of Room Area: 2,461 Square ft, Per Ton: 646 Volume (W): 25,095 S stem L"oads' d: Total Heating Required Including Ventilation Air: 35,232 Btuh 35.232 MBH Total Sensible Gain: 36,681 Btuh 80 % Total Latent Gain: 9,033 Btuh 20 % Total Cooling Required Including Ventilation Air: 45,713 Btuh 3.81. Tons (Based On Sensible + Latent) Notes ;I \\ts3400d6OO\GDCD ...\Britton Residence.rh9 I - Wednesday, January 10, 2018, 5:30 PM Rhvac -Residential & Light Commercial HVAC Loads Elite Software Development; Inc: Green{.Design Construction & De v ® rt _ asa En Trece Okeechobee, FL 34972 Page 9 System :1 Sy, stern .1:SumirlarY i .Loads: (cont Rhvac is an ACCA approved Manual J and Manual D compi Calculations are performed per ACCA Manual J 8th Edition, All computed results are estimates as building use and wea Be sure to select a unit that meets both sensible and latent your design conditions. ;r program. ersion 2, and ACCA Manual D. 3i may vary. i Is according to the manufacturer's performance data at \\ts3400d600\GDCD ...\Britton Residence.rh9 Wednesday, January 10, 2018,.5:30 PM i Rhvac Residential & Light Commercial HVAC Loads Green Design Construction & De ,. _ Elite.Sottware Development; Inc. Casa En Trace -, sue.:_ ...._ Okecehobee, FL 34972 _ _.,.. .. . , v o ,� ..L,... .� yr. _.., s • .,..Pa a 11 Di9tailed Room:•Loads.=-Room , -'Master Bedroom fA. Vera eload Procedure General; .; e Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: n/a jSystem Number: 1 Room Width: n/a one Number: 1 Area: 321.0 sq.ft. Supply Air: 241 CFM Ceiling Height: 9.3 ft. �Req. Supply Air Changes: 4.8 AC/hr Volume: 2,996 cu.ft. Vent. Olg: 0 CFM Number of Registers: 2 Pctual Winter Vent.: 25 CFM Percent of Supply.: 10 % Summer Vent.: 19 CFM �ctual ercent of Supply: 8 % Pctual Winter Infil.: 8 CFM Actual Summer Infil.: 2 CFM Item Area -U= Htg Sen Clg Lat Sen Descri tion Quanti 'Value = HTM `' a Loss ` HTM .. Gain: Gain SW-Wall-13A-5ocs 9 X 9:3 55 0.125 3.5 193 1.9 0. 105 SE-Wall-13A-5ocs 15 X 9.3 99.9 0.1.2.5 3.5 350. 1.9 0 191 NE-Wall-13A-50cs 29.2 X 9.3 225.7 0.125 3.5 790 1.9 0 432 SE-GIs-SH700 shgc-0.25 50%S (2) 40.1 0.650 18.2 - 730 18.8 0 754 NE-GIs-SH700 shgc-0.25 0%S (2) 47.2 0.650 18.2 860 24.3 0 1,150 SW-GIs-FD750 shgc-0.25 69%S 29 0.780 21.8 633 20.6 0 597 UP-Ceil-Part-16A-0 321 X 1 321 0.408 1.6 524 1.6 0 524 Floor-22A- h 53 ft..Per. 53 1.358 38.0 2,01,5 0.0 0 0 Subtotals for Structure: 6,095 0 3,753 Infil.: Win.: 8.2, Sum.: 2.1 497 0.505 251 0.068 76 34 Ductwork: 0 0 AED Excursion: 176 Equipment: 0 933 Li Atin : 120 409 Room Totals: 6,346 76 5,305 Equipment Cooling Loads =Contin " us �� ;Continuous' Output, Output Average Percent Sensible Latent Sensible ,aLatent ; ' In Use Used �� Load �� Load Item Name `Btuh Btuh' Outputt s "Hour Btuh": -Btuh Ceiling fan 250 0 100 100 250 0 Color television_ 683 0 100 100 683 0 Total 933 0 \\ts3400d600\GDCD ...\Britton Residence.rh9 Wednesday, January 10, 2018, 5:30 PM i Rhvac Residential & Light Commercial HVAC_ Loads u ;. Elite Software Development, Inc. Green Design Construe#ion & De _ n Casa En Trece Okeechobee, FL 34972 Pa a 12 Detailed Roorn:-Loads .Roorm.2. -Master WIC-." . AV e..Load: Pro' educe :.:.: Calculation Mode: Htg. & cig. Occurrences: 1 Room Length: n/a System Number: 1 Room Width: n/a one Number:, 1 Area: 34.0 sq.ft. 6upply Air: 7 CFM Ceiling Height: 9.3 ft. Supply Air Changes: 1.4 AC/hr Volume: 317 cu.ft. �eq. Vent. Cig: 0 CFM Number of Registers: 1 ctual Winter Vent.: 0 CFM �ercent of Supply:: 3 % �Eual Summer Vent.: 1 CFM Percent of Supply: 8 % Pctual Winter Infil.: 0 CFM ctual Summer Infil.: 0 CFM Item f y� �, aArea, �° U Ht �° �Sen � � � � � 9�� � ���� �,'LossHTNI���.k E.� Deser tion w'..."' xF u, 'Quantit,,.,,.w'Value°{HTM Gain.,r,.,, Gairr UP-Cell-Part-16A-0 34 X 1 34 0.408 1.6 55 1.6 0 55 . Subtotals for Structure: .55 0 55 Infil.: Win.: 0.0, Sum.: 0.0 0 0 0 0 0 0 Ductwork:. 0 0 AED Excursion: 5 Lighting: 30 102 Room Totals: 55 0 163 \\ts3400d600\GDCD ...\Britton Residence.rh9 Wednesday, January 10, 2018, 5:30 PM Rhvac Residential & Light Commercial HVAC Loads Elite Software Development, Incti & e Greer Design_ Construction D � < - Casa En Trece u ._ Oke6 ec6 hobee, FL 34972, , x< z . , _ _. _ : r _ ,. P4 a i3 Detailed Rooin:-Loads - -Rootn-.3: -'Master WIC 2 Avera e. Load. Procedure . _:.' General ?Y } °L. Y Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: n/a System Number: 1 Room Width: n/a 7one Number: 1 Area: 64.0 scift.. Supply Air: 19 CFM Ceiling Height: 9.3 ft. Supply Air Changes: 1.9 AC/hr Volume: ' 597 cu.ft. �eq. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 4 CFM ercent of Supply.: 19 �Actual Summer Vent.: 2 CFM Percent of Supply: 8 % Actual Winter Infil.: 2 CFM XI ctual Summer Infil.:. 0 CFM Item q m:F, Area U Htg I'1Sen``- Clg TLat` °Senn I "` rgF,iTM� s d� bR -.'Quariti : LossHTAA Desch tion :Ualueq _ NE-Wall-13A-5ocs 11.1 X 9.3 103.4 0.125 3.5 362 1.9 0 198. UP-Ceil-Part-16A-0 64 X 1 64 0.408 1.6 .104 1.6 0 104. Floor-22A- h 11 ft..Per. 11 1.358 38.0 418 0.0 0 0 Subtotals for Structure: 884 0 302 Infil.: Win.: 1.7, Sum.: 0.4 103 0.503 52 0.068 16 7 Ductwork: 0 0 AED Excursion: 14 Lighting: 30 102 .. Room Totals: 936 16 425 \\ts3400d600\GDCD ...\Britton Residence.rh9 I Wednesday, January 10, 2018, 5:30 PM Rhvac ResidentialA. Light Commercra o Green Desi Construction & De _ ads Software Development, Inc. Elite 'Casa En Trece_ Okeechobee, FL •34972 . ,,� � �.R ' ' , Pa a 14 Dth,: Avery :e Load .Procedure . etarled R06M.-Loa&- "Boom-.4: -'Master B a Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: n/a System Number: 1 Room Width: n/a Zone Number: 1 Area: 219.0 sq.ft. Supply Air: 95 CFM Ceiling Height: 9.8 ft. Supply Air Changes: 2.8 AC/hr Volume: 2,044 cu.ft. �- eq. Vent. Clg: 0 CFM Number of Registers: 1 actual Winter Vent.: 12 CFM Percent of Supply.: 12 % Actual Summer Vent.: 7 CFM rercent of Supply: 8 % Actual Winter Infil.: 5 CFM Actual Summer Infil.: 1 CFM Item U �Htg '� ` ` Sen Clg M Lat ;� ,Sen' 'Value ` �. G D"eseri Bari=- a Quariti_'" - " FiTMrLoss^ HaM� Gam _.. NE-Wall-13A-5ocs 13.8 X 9.3 124.3 0.125 3.5 43.5 1.9 0 238 NW-Wall-I3A-5ocs 16.8 X 9.3 128.8 0.125 3.5 451 1.9 0 246 NE-GIs-PW720 shgc-0.25 0%S 4 0.750 21.0 84 28.5 0 114 NW-GIs-HR710 shgc-0.25 0%oS 23.6 0.650 18.2 430 24.3 0 575 UP-Ceil-Part-16A-0 21.9 X 1 219 0.408 1.6 357 1.6 0 357 Floor-22A- h 30 ft..Per. 30 1.358 38.0 1,141 0.0 0 0 Subtotals for Structure: 2,898 0 1,530 Infil.: Win.: 4.6, Sum.:.1.2 281 0.506 142 0.068 43 19 Ductwork: 0 0 AED Excursion: 70 Equipment: 500 0 Lighting: 140 477. Room Totals: 3,040 543 2,096 \\ts3400d600\GDCD ...\Britton Residence.rh9 I Wednesday, January 10, 2018, 5--30 PM Rhvac - Residential & Light Commercial H_ VAC•Loads Elite Software Development; Inc. Green'bbsign Consfruction &:De. • .' Casa En Trece, Okeechobee, FL •34972 Page 15 Detcj#&d R06M' i - Loads . Room .5 - • Fo y or. Avery e.:Load -. Procedure ....: General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: n/a System Number: 1 Room Width: n/a Zone Number: 1 Area: 83.0 sq.ft. Supply Air: 46 CFM Ceiling Height: 9.6 ft. Supply Air Changes: 3.5 AC/hr Volume: 795 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 AActual Winter Vent.: 7 CFM Percent of Supply.: 16 % Actual Summer Vent.: 4 CFM Percent of Supply: 8 % Actual Winter Infil.: 1 CFM Actual Summer Infil.: 0 CFM Item Area, -U-, Htgr,l Sen Clg Lat Sen Descri tion Quantit' " . , Value H1 M Loss • HTM , Gain ... Gain NW-Part--1 0/28°-13A-5ocs 8.2 X 9.6 17.8 0.125 3.5 62 1.0 0 18 NW-GIs-FD750 in. partition 61.2 0.780 21.8 1,337 11.7 0 71.6 UP-Ceil-Part-16A-0 83 X 1 83 0.408 1.6 135 1.6 0 135 Floor-22A- h 8 ft..Per. 8 1.358 38.0 304 0.0 0 0 Subtotals for Structure: 1,838 0 869. Infil.: Win.: 1.3, Sum.: 0.3 79 0.506 40 0.063 12 5 Ductwork: 0 0 AED Excursion: 33 Lighting: 30 102 Room Totals: 1,878 12 1,010 \\ts3400d600\GDCD ...\Britton Residence.rh9 I Wednesday, January 10, 2018, 5:30 PM Rhvac Residential & Light Commercial HVAC Loads Green Design Construction & De Elite Software Development, Inc. Casa En Trece - �.:., ..w . . •.,a Okeechobee, FL 34972 e ••:. ..... r,..., Pa a 16 Di9tailed Room" Loads..= :Room .6 - .Livia Krl�cfien And:Dinind .(Average.Load:.:.:: 9 . Procedure) - General'' Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: n/a System Number: 1 Room Width: n/a Zone Number: 1 Area: 668.0 sq.ft. §upply Air: 402 CFM Ceiling Height: 12.5 ft. Supply Air Changes: 2.9 AC/hr Volume: 8,341 cu.ft. �eq..Vent. Clg: 0 . CFM Number of Registers: 3 Actual Winter Vent.: 24 CFM of Supply.: 6 % �ercent ctual Summer Vent.: 31 CFM I�ercent of Supply: bctual Winter-Infil.: 8 % 6 CFM Actual Summer Infil.: 1 CFM . Lat ,° Sea �Item 'Detcription ' Quariti Value ''' .HTM ° L_` oss HTM ` Gain°'.` Gain SE-Part--1 0/28°-13A-5ocs 23.5 X 12 150 0.125 3.5 525 1.0 0 148 SE-Part-320/28° 13A-5ocs 4.5 X 56.2 0.125 3.5 197 4.0 0 225 12.5 SE-GIs-SGD770 in partition 132 0.750 21.0 2,773 11.2 0 . 1,485 UP-Ceil-Part-16A-0 668 X 1 668 0.408 1.6 1,090 1.6 0 1,090 UP-Ceil-Part-16A-0 118.6 X 1 118.6 0.408 1.6 194 1.6 0 194 Floor-22A- h 28 ft..Per. 28 1.358 38.0 1,065 0.0 0 0 Subtotals for Structure: 5,844 0 3,142 Infil.: Win.: 5.6, Sum.: 1.4 338 0.506 171 0.068 52 23 Ductwork: 0 0 AED Excursion: 293 Pe©ple: 200 lat/per, 230 sen/per: 4 800 920 Equipment: 683 3,885 Lighting: 170 580 Room Totals: 6,015 1,535 8,843 E ui meat Coolin Loads. Continuous-�>Contmuousx ; ut. Avea a Sensib nett Sensible *,Latent In Use UsedLoad Item'Narne'."Btuh<'�' ,'Btuh��-�Qut "uf� '' erH"`our �Btuh, �''iBtu_f` Cooking range with hood - 0 0 100 100 0 0 four burners on high heat Microwave 4949 1732 75 25 928 325 Dishwasher 4096 1433 100 25 1024 358 Refrigerator or freezer - 16 1000 0 100 100 1000 0 cubic feet Color television 683 0 100 100 683 0 Ceiling fan -------------------------------------------- 250 - - - --- 0 - • ------------ 100 - ------------------------------------- 100 250 ----------------------------------------------- ------------------ 0 ­_____. 3885 683 \\ts3400d600\GDCD ...\Britton Residence.rh9 Wednesday, January 10, 2018, 5:30 PM i Rhvac Residential &Light Commercial HVAC Loads _ Elite Software Development, Inc. Gr'e'6A Design Construction.& De ; , - y v T Casa En.Trece ,e Okeechobee, FL 34972 Pa 17 Retailed Room Loads Room► .7 -Bedroom,- : ' Avera e-LQad"Procedure :.:.: General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: n/a System Number: 1 Room Width: n/a Zone Number: 1 Area: 154.0 sq.ft. Supply Air: 106 CFM Ceiling Height: 9.3 .ft. Supply Air Changes: 4.4 AC/hr Volume: 1,437 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Xctual Winter Vent.: 6 CFM Percent of Supply.: 6 % Actual Summer Vent.: 8 CFM PPercent of Supply: 8 %o Actual Winter Infil.: 2 CFM Actual Summer Infil.: 0 CFM Item 'Area -U- Htg Sen Clg , Lat '; Sen Description Quanti Value HTM .. Loss HTM Gain' Gain NW-Wall-13A-5ocs 12.4 X 9.3 83.1 0.125 3.5 291 1.9 0 159 NW-GIs-HR710 shgc-0.25 0%S 32.8 0.650 18.2 597 _ 24.4 0 799 UP-Cell-Part-16A-0 154 X 1 154 0.408 1.6 251 1.6 0 251 Floor-22A- h 12 ft..Per. 12 1.358 38.0 456 0.0 0 0 Subtotals for Structure: 1,595 0 1,209 Infil.: Win.: 1.9, Sum.: 0.5 116 0.509 59 0.069 18 8 Ductwork: 0 0 AED Excursion:. 77 Equipment: 0 933 Lighting: 30 102 Room Totals: 1,654 18 2,330 E ° i ment Cooling.Loads Continuous, �,,Continuous.,, ,Output Output Average Percent Sensible Latent Sensible ' Latent , In Use" Used.' ;Load Load Item Name' Btuh, x Btuh Out ut° " er our Btuh Btuh Ceiling fan 250 0 100 1.00 250 0 Color television 683 0 100 100 683 0 Total 933 0 \\ts3400d600\GDCD ...\Britton Residence.rh9 I Wednesday, January 10, 20.18;.5:30 PM Rhvac Residential & Light Commercial HVAC Loads Green. DesignConstruction& De µ . Elite Software Development, Inc. Casa En Trece Okeechobee, FL 34972 , : Detailed Room: Loads--=-Room-.B.-'Bedrao►n 2,Avers '16ad:'Procedure General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: n/a System Number: 1 Room Width: n/a lone Number: 1 Area: 152.0 sq.ft. Supply Air: 102 CFM Ceiling Height: 9.3 ft. Supply Air Changes: 4.3 AC/fir Volume: 1,419 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 9 CFM Percent of Supply.: 9 % Actual Summer Vent.: 8 CFM Percent of Supply: 8 % Actual Winter Infil.: 4 CFM Actual Summer Infil.: 1 CFM Item; Area -U- Wtg ., ;$en Clg ,Lat, ; Sen Description Quantit' -Value HTM Loss HTM Gaim Gain NW-Part-320/28° 12B-0bm 13.4 X 125.2 0.112 3.1 393 3.6 0 449 9.3 SW-Wall-13A-5ocs 10.2 X 9.3 79.8 0.125 3.5 279 1.9 0 153 SW-GIs-SH700 shgc-0.25 63%S 15.8 0.650 18.2 288 17.4 . 0 275 U P-Ceil-Part-1 6A-0 152 X 1 152 0.408 1.6 248 1.6 0. 248 Floor-22A- h 24 ft..Per. 24 1.358 38.0 913 0.0 0 0 Subtotals for Structure: 2,121- 0 1,125 Infil.: Win.: 3.6, Sum.: 0.9 221 0.507 - 112 0.068' 34 15 Ductwork: 0 0 AED Excursion: 75 Equipment: 0 933 Lighting: 30 102 Room Totals: 2,233 34 2,250 Equipment .Coolin ,Loads Continuous",, bContinuous Output Output, g ' Ayers a Percent , ;' Sensible :Latent Sensible ;Latent In`Use' Used Load " 16Ad Item, Name �Btuh.= `Btuh Out ut� per, our '13tuh. �Btuh Ceiling fan 250 0 100 100 250 0 Color television 683 0 100 100 683 0 Total 933 0 \\ts3400d600\GDCD ...\Britton Residence.rh9 I Wednesday, January 10, 2018, 5:30 PM Rhvac T. Residential &Light Commercial HVAC Loads_ Green Design Construction & De A a o.. a. .. _.. ■ Elite Software Development, Inc. Casa En Trece Loa �.., Okeechobee, FL 34972 a 19 [Detailed Rooiri:•Loa6---R60"M" -.9 -'In=Law Suite: (Average Load:Procedure „ General= 6 �ti� Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: n/a System Number: 1 Room Width: n/a Zone Number: 1 Area: 359.0 sq.ft. Supply Air: 386 CFM Ceiling Height: 9.3 ft. Supply Air Changes: 6.9 AC/hr Volume: 3,351 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 21 CFM Percent of Supply.: 5 % Actual Summer Vent.: 30 CFM PIercent'of Supply: 8 % P'ctual Winter Infil.: 7 CFM Actual Summer Infil.: i 2 CFM Item Area U Htg Sen Clg Lat °` Sen Description Quantit ,,' Value" HTM Loss HT(ul Gam ` Gain SW-Wall-13A-5ocs 19.4 X 9.3 157.6 0.125 3.5 552 1.9 0 301 SE-Wall-13A-5ocs 15 X 9.3 99.9 0.125 3.5 350 1.9 0 191 NE-Part--1 0/28°-13A-5ocs 4.5 X 9.3 42 0.125 3.5 147 1.0 0 41 NE-Part-320/28°-13A-5ocs 4.5 X 9.3 13 0.125 3.5 46 4.0- 0 52 SW-GIs-SH700 shgc-0.25 60%S (2) 23.6 0.650 18.2 430 17.7 0 418 SE-GIs-SH700 shgc-0.25 50%S (2) 40.1 0.650 18.2 730. 18.8 0 754 NE-GIs-FD750 in partition 29 0.780 21..8 633 25.0 0 723 UP-Ceil-Part-16A-0 359 X 1 359 0.408 1.6 586 1.6 0 .586 Floor-22A-ph 43 ft..Per. 43 1.358 38.6 1,635 0.0 0 0 Subtotals for Structure: 5,109 0 3,066 Infil.: Win.: 6.7, Sum.: 1.7 405 0.506 205 0.069' 62 28 Ductwork: 0 0 AED Excursion: 281 People: 200 lat/per, 230 sen/per: 1 200 230 Equipment: 722 4,188 Lighting: 200 682 Room Totals: I 5,314 _ 984 8,475 Equipment Coolie` 'Loads' I.F y ` Continuous; ° s ���,� yr4 2 `"` ` Averages„ ¢ +` Output Output` Percent^' y Sensible , Eatent< Sensible* LatenC. In Use; Used ` �: Load ,3. :Load Item Name 13tuh Btufi . Ou ut er Hour . Btuh . __. B#uh Dishwasher 4096 1433 100 25 1024 358 Refrigerator or freezer - 12 700 0 100 100 700 0 cubic feet Microwave 4949 1732 75 25 928 325 Ceiling fan 250 0 100 100'. 250 0 Color television 683 0 100 100 683 0 Toaster 3532 392 100 10 353 39 Ceiling fan - - 250 0 --100----------------- 100 -250 - - - -0 Total 4188 722 \\ts3400d600\GDCD ...\Britton Residence.rh9 I Wednesday, January 10, 2018, 5:30 PM I Rhvac Residential & Light Commercial HVAC Loads _ Elite Software Development, Inc. Green Design Construction & De _..., ■ Casa En Trece Okeechobee, FL 34972 ti.. _ :.. . - - Pa �e�20 Detailed Room: Loads=-R6orn40'--1h aW.:-W1C--Averag e Load Procedure :.:.: General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: n/a System Number: 1 Room Width: n/a Zone Number: 1 Area: 58.0 sq.ft. Supply Air: 15 CFM Ceiling Height: 9.3 ft. Supply Air Changes: 1.6 AC/hr Volume: 541 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 2 CFM Percent of Supply.: 15 % Actual Summer Vent.: 1 CFM Percent of Supply: 8 % Actual Winter Infil.: 1 CFM Actual Summer Infii1.: 0 CFM Item £ , Area s w ,r= ., ., ,t mE fv t ', ; I �U � , rHtg� fi. r Sen `tion:, Desci r: _ _ r _Quanti Lo�sstt�HTM --- . _ fGain ; ✓Gain SW-Wall-13A-5ocs 6.3 X 9.3 59.1 0.125 3.5 207 1.9 0 113 UP-Ceil-Part-1 6A-0 -58 X 1 58 0.408 1.6 95 1.6 0 95 Floor-22A-ph 6 ft..Per. 6 1.358 38.0 228 0.0 0 0 Subtotals for Structure: 530 0 208 Infil.: Win.: 1.0, Sum.: 0.2 59 0.508 30 0.068 9 4 Ductwork: 0 0 AED Excursion: 11 Lighting: 30 102 Room Totals: 560 9 325 \\ts3400d600\GDCD ...\Britton Residence.rh9 I Wednesday, January 10, 2018, 5:30 PM i Rhvac r Residential &- Light Commercial HVAC Loads Elite Software Development, Inc: Green' Design Construcfion & De _ - _ . ■ _, : ;. : . ..., Casa En Trece Okeechobee, FL .34972 Page 21 -Detailed Room" -Loads. Rooro-.1:1 *,• In:=Laud Bath-: Avera e'.Load-Procedure . :*•..:- General. Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: n/a System Number: 1 Room Width: n/a Zone Number: 1 Area: 88.0 sq.ft. Supply Air: 54 CFM Ceiling Height:, 9.3 ft. Supply Air Changes: 8.9 AC/hr Volume: 821 cu.ft. Rieq. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 4 CFM Percent of Supply.: 8 % Actual Summer Vent.: 4 CFM Percent of Supply: 8 % Actual Winter Infil.: 2 CFM Acitual Summer Infil.: 0 CFM Item Areal U-. Htg Sen Clg Lat Sen Description .' Quanti " ; `Value. HTM . ° Loss " HTM :: Gain Gain SW-Wall-13A-5ocs 10.9 X 9.3 92.1 0.125 3.5 322 1.9 0 176 SW-GIs-SH700 shgc-0.25.100%S 9.8 .0.6.5.0 18.2 177 13.5 0 132. UP-Ceil-Part-16A-0 88 X 1 88 0.408 1.6 144 1.6 0 144 Floor-22A-ph 11 ft..Per. 11 1.358 38.0 418 0.0 0 0 Subtotals for Structure: 1,061 0 452 Infil.: Win.: 1.7, Sum.: 0.4 102 0.501 51 0.069 16 7 Ductwork: 0 -0 AED Excursion: 39 Equipment: 500 478 Lighting: 60 205 Room Totals: 1,112 516 1,181' Equipment CoolinLoads Continuous ° r N Confinuous Outut °Average? �Seris�ble Eltem Sensible';, Latent- a -^Percent 1n Use: Used ar,�oame . : , Btuh ` Btiih : Out ut. .. ' Per Hour. Btuh ", ` Btuh Vented clothes dryer - 10 1707 0 50 50 427 0 percent to space Clothes washing machine - 205 0 50 50 51 0 10 percent to space Miscellaneous Equipment 0 500 - - - 100 100 ------•-------- --- - - --- 0 - - - - 500 - -------------- Total 1 I I 478 500 \\ts3400d6Oo\GDCD ...\Britton Residence.rh9 I Wednesday, January 10, 2018, 5:30 PM I Rhvac - Residential & Light Commercial HVAC Loads :. Elite Software Development, Inc. Green Design Construction &;De ■ „ . , r Casa En Trece _- Okeechobee, FL •34972 _ Pjja 22 •Detailed R06m:•L6ads-=.Room..:12'---Bath: 1.:',Averao e'Load.Procedure Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: n/a System Number: 1 Room Width: n/a Zone Number: 1 Area: 162.0 sq.ft. Supply Air: 34 CFM Ceiling Height: 9.3 ft. Supply Air Changes: 1.3 AC/hr Volume: 1,512 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 2 CFM Percent of Supply.: 7 % Actual Summer Vent.: 3 CFM Percent of Supply: 8 % Actual. Winter Infil.: 1 CFM Actual Summer Infil.: 0 CFM Item r - Areal , U x ` Ht k. ' xSen �< Clg uk , L�at Sen= �.' 9� - � �'��r R rye' " ���� Quanti- H HTM4, Cara � Gale; Deseri tion : ` o, �Ualue,.> kM¢ ;Loss _. ::, _ SW-Wall-13A-5ocs 6.3 X 9.3 49.4 0.125 3.5 173 1.9 0. 94 SW-GIs-SH700 shgc-0.25 100%S 9.8 0.650 18.2 177 13.5 0 132 UP-Ceil-Part-16C-30 162 X 1 162 0.032 0.1 21 0.1 0 21 Floor-22A-ph 6 ft..Per. 6 1.358 38.0 228 0.0 0 0 Subtotals for Structure: 599 0 247 Infil.: Win.: 1.0, Sum.: 0.2 59 0.508 30 0.068 9 4 Ductwork: 0 0 AED Excursion: 25 People: 200 lat/per, 230 sen/per: 1 200 230 Equipment: 500 0 Lighting: 70 239 Room Totals: 629 I I I 709 744 \\ts3400d600\GDCD ...\Britton Residence.rh9 Wednesday, January 10, 2018, 5:30 PM Rhvac - Residential & Light Commercial HVAC Loads _ Elite Software Development, -Inc. Green-Design.0& De _ - Casa En"Trece 349onstr72uction Okeechobee, FL _ Page 23 Detailed Rooin:-Loads • •Room .13'�- Utili • Avera a Laad Procedure :'-•." General' 777: Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: n/a System Number: 1 Room Width: n/a Zone Number: 1 Area: 99.0 sq.ft. Supply Air: 69 CFM Ceiling Height: 9.3 ft. Supply Air Changes: 4.5 AC/hr Volume: 924 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 7 CFM Percent of Supply.: 10 % Actual Summer Vent.: 5 CFM Percent of Supply: 8 % Actual Winter Infil.: 3 CFM Actual Summer Infil.: 1 CFM Item Area U- ,Htg Sen Clg Lat Sen tion, QUA' T ,Gailtl s , nDescri ' NW-Part-320/28°-1213-0bm 7.6 X 9.3 42.5 0.112 3.1 133 3.6 0 152 NE-Wall-13A-5ocs 10.2 X 9.8 95.7. 0.125 3.5 335 1.91 0 183 NW-Door-11 N 3.5 X 8.1 28.3 0.350 9.8 277 11.2 0 317 UP-Ceil-Part-16A-0 99 X 1 99 0.408 1.6 162 1.6 0 162 Floor-22A-ph 18 ft..Per. 18 1.358 38.0 684 0.0 0 0 Subtotals for Structure: 1,591 0 814 Infil.: Win.: 2.7, Sum.: 0.7 166 0.505 84 0:066 25 11 Ductwork: 0 0 AED Excursion: 50 Equipment: 0 478 Lighting: 45 153 Room Totals: I 1,675 25 1,506 E ui ment Coolin Loads . :Continuous • i 1� • r/„yJ Y Continuous TL 11 i1 b' r3.E 'h i' r Qutput` :e ;, Qutput ,b 1! !.' i"f9 :• Average , PercentL Sensible ;Latent; _, v Sensible _Latent,'� Used>L�oad `�'� . Load Item Name `Btuh ; Btuh Out tat .,. ''per, Hour 4 : ' �. _ _ :Btuh' • 13tuh Vented clothes dryer - 10 1707 0 50 50 427 0 percent to space Clothes washing machine - 205 0 50 50 51. 0 10 percent to space _ _ -_ -------------------------------- --------- ---------------------------- - - - - Total 478 0 \\ts3400d600\GDCD ...\Britton Residence.rh9 I Wednesday, January 10, 2018, 5:30 PM Rhvac Residential & Light Commercial HVAC Loads `. _ Green Design Construction & De ' ' .. Elite Software Development; Inc., Casa EnATrece Okeechobee, FL 34972 r Page 24 •Systerh-TRootn Load Suinrna :: :.; . n t •:, i< ; : f u tHtge �,�N1inr yRu, t x'Rn Clgc ,' `Clg Mimd� ,4Act 'CI9 �k'0 RoomN_ � Ht j©duct= "'Vel Sens ; LatK' Sys: "SF" Btuhw �''CFM ` � Size ; NO'] No�x`Name :, . - ---Zone 1--- 1 Master Bedroom 321 6,346 82 7,7 - 5,305. 76 241 241 2 Master WIC 1 34 55 1 4 - 163 0 7 7 3 Master WIC 2 64 936 12 4 - 425 16 19 19 4 Master Bath 219 3,040 40 6 - 2,096 543 95 95 5 Foyer 83 1,878 24 4 - 1,010 12 46 46 6 Living Kitchen 668 6,015 78 7,7,7 - 8,843 1,535 402 402 And Dining 7 Bedroom 1 154 1,654 21 6 - 2,330 18 106 10.6 8 Bedroom 2 152 2,233 29 6 - 2,250 34 102 102 9 In -Law Suite 359 5,314 69 8,8 - 8,475 984 386 386 10 In -Law WIC 58 560 7 4 - 325 9 15 15 11 In -:Law Bath 88 1,112 14 5 - 1,181 516 54 54 12 Bath 1 162 629 8 4 - - 744 709 34 34 13 Utility 99 1,675 22 5 - 1,506 25 69 69 Ventilation 3,785 2,028 4,556 System 1 total 2,461 35,232 409 36,681 9,033 1,577 1,577 System 1 Main Trunk Size: 15x22 in. Velocity: 688 ft./min Loss per 100 ft.: 0.051 in.wg Duct size results above are from Manual D Ductsize. Runout duct velocities are not printed with duct size results from anual D Ductsize since they can vary within the room. See the Manual D Ductsize report for duct velocities and other data. Coolim ,5 stem 50ma ,Coglmg , t r €_Sensible, t w Latent, �E �Total' Sensible/Latent 4"""" ' Ton's wS lit ° ' r `'`BtuhBtuh , t Btuh Net Required: 3.81 80% / 20% I 36,681 9,033 45,713 E ui mentData Heating System Cooling System Type: Natural Gas Furnace Standard Air Conditioner Model: Indoor Model: Brand: Efficiency: 0 AFUE 0 SEER Sound: 0 0 Capacity: 0 Btuh 0 Btuh Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a I 0 Btuh \\ts3400d600\GDCD ...\Britton Residence.rh9 I Wednesday, January 10, 2018, 5:30 PM