HomeMy WebLinkAboutPRODUCT APPROVAL WINDOWS MULLIONSFlorida Building Code Online I Page 1 of 3
i 0CANNED
• ` 0 ® e . i BY L t•
5t Lucie County 2-3
BCIS Home Log In User Registration Hot Topic � Submit Surcharge I Stats & Facts Publications Contact Us • BCIS Site Map I Links Search
bprodU=ApprovalC�tStt����ER: lic User
G�'tTaaWr�0.itn
Product Aooroval Menu > Product or Aoolicatlon Search > Application List > Application Detail
+
i
•' FL #
FL5777-R5
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
❑
Product Manufacturer
Custom Window Systems Inc.
Address/Phone/Email
1900 SW 44th Avenue
Ocala, FL 34474
(352)368-6922 Ext291
jlathrop@cws.cc
Authorized Signature
Kevin Pine
i
kpine@cws.cc
Technical Representative I
Jay Lathrop
Address/Phone/Email
1900 SW 44th Ave
Ocala, FL 34474
(352)368-6922 Ext291
jlathrop@cws.cc
Quality Assurance Representative
Arturo Monteverde
Address/Phone/Email
1900 SW 44th Ave
Ocala, FL 34474.
(352)368-6922 Ext221
amonteverde@cws.cc
Category
Windows
Subcategory I
Mullions
Compliance Method I
Evaluation Report from a Florida Registered Architect or a Licensed
i
Florida Professional Engineer
i
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
the Evaluation Report
.Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
I
i
Equivalence of Product Standards
Certified By
Lucas A. Turner
PE-58201
Keystone Certifications, Inc.
07/21/2020
Steven M. Urich, PE
R'l Validation Checklist - Hardcopy Received
FL5777 R5 COI EvalReport244C.odf
Standard
AAMA 450-10
AAMA/WDMA/CSA 101/I.S.2/A440
TAS 202
Florida Licensed Professional Engineer or Architect
FL5777 R5 Eauiv FL5777 Eauivalencv.ndf
Year
2010
2005
1994
Ffe Copy
https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgs%2bZ 1 jLJBT... 8/27/2018
Florida Building Code Online Page 2 of 3
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
I
I
i
I Method 1 Option D
09/29/2017
09/29/2017
10/02/2017
12/12/2017
FL # IModel, Number or Name Description
5777.1 Adjustable (Angled) Mull Adjustable Mullion for Alum. and PVC Windows.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL5777 R5 II CWS-243C.odf
Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: Not for use in HVHZ. See Mullion Product Evaluation FL5777 RS AE EvalReport243C.pdf
Report for complete list of Limitations and Conditions. Created by Independent Third Party: Yes
5777.2
CWS-1758 Mull Bar I
3" Mull Bar for PVC Windows.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL5777 R5 II CWS-430C.pdf
Approved for use outside HVHZ: Yes
Verified By: Lucas A. Turner 58201
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See Mullion Product Evaluation Report for complete
FL5777 R5 AE EvalReport430C.Ddf
list of Limitations and Conditions of Use. I
Created by Independent Third Party: Yes
5777.3
CWS-1759 Mull Bar I
4" Mull Bar for PVC Windows.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL5777 R5 II CWS 431C.pdf
Approved for use outside HVHZ: Yes
Verified By: Lucas A. Turner 58201
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A I
Evaluation Reports
Other: See Mullion Product Evaluation Report for complete
FL5777 R5 AE EvalReport431C.pdf
list of Limitations and Conditions of Use. ICreated
by Independent Third Party: Yes
5777.4
CWS-1760 Mull Bar
5 1/2" Mull Bar for PVC Windows.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL5777 R5 II CWS-432C.odf
Approved for use outside HVHZ: Yes
Verified By: Lucas A. Turner 58201
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See Mullion Product Evaluation Report for, complete
FL5777 R5 AE EvalReoort432C.Ddf
list of Limitations and Conditions of Use.
Created by Independent Third Party: Yes
5777.5
CWS-1950 Mull Bar
2" Mull Bar for Aluminum Windows.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL5777 R5 II CWS-245C.odf
Approved for use outside HVHZ: Yes
Verified By: Lucas A. Turner 58201
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -N/A
Evaluation Reports
Other: Not for use in HVHZ; See Mullion. Product Evaluation
FL5777 R5 AE EvalReport245C.pdf
Report for complete list of Limitations and Conditions of Use.
Created by Independent Third Party: Yes
5777.E CWS-1952 Mull Bar 3" Mull Bar for Aluminum Windows.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL5777 R5 II CWS-244C.odf
Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: +N/A/ -N/A Evaluation Reports
Other: Not for use in HVHZ; See Mullion Product Evaluation FL5777 R5 AE Eva I Repo rt244C, Ddf
Report for complete list of Limitations and Conditions of Use. Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
i
The State of Florida Is an AA/EEO employer. Coovriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
htts://www.floridabuildin .or / r/ r_a dtl.as x? atom=wGEVX wtD s%2bZ1'LJBT... 8/27/2018
P g g P P PP_ P P• Q Q J
Florida Building Code Online
Page 3 of 3
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please
Approval
hers..
Product Approval Accepts:
�m in , eCli
Credit Card
Safe
1
https://www.floridabuilding.org/pr/P _app_dtl.aspx?param=wGEVXQwtDgs%2bZ1jLJBT... 8/27/2018
ANCHOR CLIP
3" PVC MULL BAR - NON -IMPACT
SHOWN W/DIFFERENT OPTIONS
G F E (D) IL ANCHOR CLIP
10 10 9 9
EXAMPLE HORIZ/.VERT. MULLION
FOR SECTION VIEW ONLY
TABLE OF CONTENTS
GENERAL NOTES & ELEVATIONS...............1
DP CHARTS.................................................2-3
BOM & EXTRUSIONS.....................................4
EXTRUSIONS.................................................5
SECTION VIEWS.........................................6-7
CONFIGURATIONS & ANCHOR NOTES
INSTALLATION DETAILS ..........................9-10
ANCHOR CLIP
GENERAL NOTES-
1.1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH
THE FLORIDA BUILDING CODE (FBC), CURRENT EDITION.
1900 SW 44TH AVE.
2. CONFIGURATIONS (SEE SHEET 2): VERTICAL OR HORIZONTAL.
OCALA, FLORIDA 34474
W W W.CWS.CC
3. SEE MULLION CHARTS FOR MAX. DESIGN PRESSURES AND LENGTH.
(REFER TO SHEETS 2-3)
3" PVC
4. ANCHORAGE: THE 33 1/3 % STRESS INCREASE HAS NOT BEEN USED IN THE
DESIGN OF THIS PRODUCT. SEE SHEETS 9-10 FOR ANCHOR DETAILS. WINDLOAD
MULL BAR
DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS.
NON -IMPACT
5. NOT APPROVED FOR IMPACT RESISTANCE. IMPACT PROTECTIVE SYSTEM IS
REQUIRED IN WIND BORNE DEBRIS REGION.
¢
Z C
O
6. DESIGN PRESSURE OF MULLED UNITS SHALL BE CONTROLLED BY THE LESSER
Z
Z
w w o WHO*
Z w
DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL WINDOW UNITS.
w
z 0 z a - -
am->-Ow�m
7. DESIGN PRESSURES AND INSTALLATION DETAILS SHOWN IN THIS DOCUMENT
LL Z
_ z W a a, W 0 p
APPLY ONLY TO THE MULLION. WINDOWS MUST BE APPROVED UNDER SEPARATE
0
O F- 0 �j ¢ = f- fY
l- a
APPROVAL.
0
Z- y- Z D
8. RESPONSIBILITY OF SELECTING FENESTRATION PRODUCTS TO MEET ANY
APPLICABLE
Q
�
- Z a U) O 0 a 0
LOCAL LAWS, BUILDING CODES, ORDINANCES OR OTHER SAFTEY
REQUIREMENTS RESTS SOLEY WITH THE
Cltw- F F_ Z
ARCHITECT, ENGINEER OF RECORD,
BUILDING OWNER OR CONTRACTOR.
F
0_fi} O
Oa
w_
0O w U) w
9. SINGLE UNITS TO BE MULLED ARE NOT LIMITED TO THOSE SHOWN IN THIS
It
p
z-a
w I=- O a -
DRAWING. SINGLE UNITS TO BE MULLED TOGETHER MUST BE MANUFACTURED BY
a
rn
a K �
-CUSTOM-WINDOW SYSTEMS;-INC.-AND-MUST-BE-MADE-OUT OF VINYL PVC -OR
-
-� aw
EXTRUDED ALUMINUM.
10. VERTICAL MULLED UNITS MAY BE MULLED INDEFINITELY AS LONG AS THE SINGLE
UNIT WIDTH AND HEIGHT ARE NOT EXCEEDED, AND MULLIONS
ARE ANCHORED AS
SHOWN
.�����t�ORE41�rrr4
��cEWSF
HERE IN.
11. HORIZONTAL MULLION SHALL EXTEND THE ENTIRE WIDTH OF THE MULLED UNIT.
�;� No 58201 .-P
VERTICAL MULLION IS USED TO MULL SIDE BY SIDE UNITS TOGETHER.
= * E
ANCHOR CLIP
I O
II
O
I X
I I
II
X I
I
4
4
nucuna ri io
EXAMPLE VERTICAL MULLION FOR
PVC WINDOWS FOR SECTION VIEWS ONLY
Lucas
Turner
2017-09-28
07:10+20:00
X�
9/26/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
GENERAL NOTES AND
ELEVATIONS
IRS 1 04/13/09
CWS-430 C
uE SHEET
1:25 1 OF 10
0
i
n
L
'a
z
G)
cn
T
IYIULL LCIVU I fl
I•� MULLLENGTH
o ny�
z F
Z
6] 3 z
y
m r
L o
z
l r— MULL LENGTH
--I
O <
m m
z
z =I
O n
N .A -a
m
cm
T r
0
z
r— OPENING SIZE-�i
I
O
�1
c
r
mZLO�Z
O
m
0���—M.-
0
zz v
MULL
LENGTH
(in.)
z
u z 0
a m acne _
W m D
-4 m
O
G cn
W
W
N
N
u
o
g
O
N
a
W
VI
n
W
A
OC
A
N
W
u (� O
D ,il
A� OHO
Oo
Oo
Qr
O
A
O
Or
W
A
W
A
A
O I7
O z
V O�
mm cyiO1 -I(n
.I
o
0 :0 '0 �0
C ca � ..
'
V
W
N
N
N
m
W
O
W
V
A
N
m
-�
m
N
V
m
W
W
O
W
f
V
N
0
N
0
N
0
N
0
N
0
N
6
N
0
W
w
o m
3 W
!� co
U
r > w
0
�m
cm
V
C7
N
T
N
V
A
A-4
V
O
A
W
0
0
0
0
0
O
z1
O z
O 0
�' (1
m0 °o^
r 0 2
O Oo
T
v
C m N
O V -I Z
,I
-�
f/>
_
V
N
O
NJN
W
c0
W
W
W
(0
A
W
m
(0
m
c0
W
CO
A
N
0
0
0
0
0
0
't
np 0
D
Z X
0 nr F
W Z
o O
O � X
O _ <
I
--•
N
N
m
N
c0
W
m
A
W
U1
W
m
N
V
W
W
m
(D
W
O
o
N
N
0
N
0
N
0
N
O
N
V
r?
O m
z m
O 0 A
W
W
A
m
m
V
Co
(O
o
-
N
N
m 0
-n
rz
O
m
W
A
m
0
O
O
ON
Wm
CZr
Z
0v0
ZC
O .Zl m
m
N
N
wWNm
1-4
N
V
W
c0
ON
w
w
o
NO
o
W
cO
A Z W
X
m
mm O c
O r r
0 m
0 XI
I
N
I")N
W
A
A
Ul
m
V
V
W
(0
NO
NO
V
fC O Z
IT!
m
O
W
W
A
N
W
m
m
A
(0
OD
cJl
�
CA-{
O=
0
Q
n z V
(11
_
W
0)
N
N
A
N
NO
a
mCzC
� m
-N-�
-W+
w(AI
W
(WO
OWo
W
z
Z
C
O
zi
•
I
W
N
O
N
A
N
c0
W
m
A
N
A
f0
m
V
m
m
m
W
V
V
W
W
(O
N
O
N
W
V
X
f!1 D
m
O
-.�
P
J 2 r
m
� ;u
n
V
c0
(N.l
V
CO
rn
(�rvr�i
m
m
V
V
COW
W�
c0
. m
two
A'
�cnw(0a)(D
W
;u
00
m
W
ONl
N
V
W
!N
W
N
cm0
A
(O
w
O
r =
� N
m
m
N
O
N
A
W
0
W
A
O
V
A
m
W
m
A
m
CJ
V
m
W
W
nl
u
W
00,
,'c07 V
O O)
C V
1 n
m
W
N
CO
N
V
A
.A
O
CA
N
Owl
A
r
r W
IT! c
o (n
ao z
r 0
_
N
N
W
W
A
A
m
Ln
m
m
V
c0
0
m
W
m
O
m
N
(D
N
W
N
W
W
n 0
A C
Z1
(� A
-•
N
N
W
W
A
A
(Jl
m
m
j
W
C#
m
a7
A
m
N
W
V
W
V
N
W
N
'a O
W m
T n
m
W
N
C.
O
cn
,pp
A
cA0
N
((77ll
V
m
T
O CX
C m
fn
m
. O
a
m
m
m m
N
z N
n
tpUrn{{{{I
,,,,����� lF: it
�: g : (P .
PROPRIETARY
PROPRIETARY AND CONFIDENTIAL
* O m
THE INFORMATION CONTAINED IN
o
D -u z
z$ n
(o r y
° +' ��r .�' z „9'
h rO.o n ,
THIS DRAWING IS THE SOLE
Z C W
T
ulp$ g�
n o
2 V 2 z
-�Dm1
W O W
co D c
o.�o
3z r
c l _ yl m '4 m 2j rn "-
PROPERTY OF CUSTOM WINDOW
SYSTEMS, INC. ANY
r-
r '�
0 z m
n c D
D
0
_
o m
'
V
N 1
m co Z
r
�r O O o 'n: '
:9 *+
REPRODUCTION IN PART OR AS A
W C
Ci
m' o^
H
ON
n
C o
m
aco
��2 Cy,�
�i�C'ti�R�,r�,�'��p`
WHOLE WITHOUT THE WRITTEN
PESYSITEMS,
> D
A
c
m
NCCIS PROHIBITED.
MULL LENGTH-1
O
Z
0
En
N
L
LI- ,., ���u. ,,,--1
O
v
Z
0
rh
N
F--- MULL LENGTH --I
m�
;oO
DK
r0
c m
O -S1
Z Z
�CD
�3
r0
3m
C A
zv
m
m
o
z
D
r_
G1
N
C Z
N
r
LZ
L F-- MULL LENGTH
I
O
m
m
m
z
i
z
GI
D A
N
N
rT
�r
cm
r
T
t
O
Z
F� OPENING SIZE --I
I
L
O
r
wc-4 to
mz� Z
r-O
-ut-
ZOZ
-I
m
O
�) m Z-
3
�
_� _m
c
L
°
Z
z o
MULL
LENGTH
(in.)
o
mmrn� Zm
9
rq o
a
n
a
a
0
` ito �
n
00
N
O)
O
A
W
N
Q'
O
A
O
O)
N
W
W
J
•+
W
W
�J
A O)�� ��A
— c)
pp
A
OD
F
A
` X
m
-+
�!
W
N
N
N
O)
W
O
W
V
A
N
O)
O)
N
V
Of
W
co
O
_
N
_
N
_
N
_
N
N
_
N
_
N
N
W
O
r w n
m
0 c-
N••
rn co)
_ cn
.1.J
< X
C D
r�- r
W
O
O
O
O
O
do
O
.Z%
-Im
�n ZZ
Oo
(n
NO)O
V
A
O
O
O
O
O41
c$%
ZZm
co
r p
..
D
co
rmN
= O
W
N
NN
N
0 -n
O
0
I
D
W
(D
(D
0
0
0(D
C)
0
0
X
D�p0
rD
DZ
OC
O r-
O Z
X
N
N
N
W
A
N
O)
V
W
O
N
N
N
N
N
N
N
W m
O Z
W
Ut
W
W
N
W
O)
co
O
O
O
O
O
O
V
O o 'X
2
-n O D
D)
W
N
A
N
V
W
N
W
(D
A
(D
W
07
V
(O
C
V
V
co
(O
m
O
O
O
C.
O
W
i Z
m0 cn
m c
QJ Z z
r n L7
c W
O.'n m
'
V
N
1IVV
N
Ul
W
O
W
O)
A
W
N
Q)
V
(O
O
N
N
N
N
N
O
m 3
0 'm'I _
(T
N
--�
co
O
O
O
O
O
O
X C
m m
O 3
m
o
g v
p m
A
N
N
N
W
A
A
(J1
Q)
aV
W
NO
NO
V
CmZ
C m 2
O
O m
O)
CDW
co
A
N
co
O)
O)
W
(D
O
O
ON
CA
Z
0
O
V
'u
m
O)
V
(O
N
N
N
N
N
Z
C O
Vt
O
O)
(D
(n
N
N
V
N
O
O
O
O
O
Z
c r '�
r N
r o O
O
A
N
V
N
CO
CO
v�0
pr
O)
coN
OW)
(AO
M
O
O
O
C
V=
O
7
O �C
fTl
V
(D
W
V
A
(WD
m
A
W
0
O
N
N
N
N
O O
co
O
O
O
O
W
G) D
f
p
C
_
N
N
W
W
A
Vt
W
V
O
-�
N
N
N
O
r=
O
O
O
W
r
O V
_
O)
O
A
O
A
O
v
(�D
O
(07)
'
O
O
O
o
W
mr
p_
N
W
(D
M m En
O
O)
W
N
OD
N
V
A
O)
O)
(D
M
Ul
mO
0
A
m X
en
OD
• -�
O)
O
CD
N
W
W
A
O
N
N
N
y
O
O
O
O
O
A O
o
O W
O)
(D
A
W
N
W
M
V
V
O
01
O
N
C Z
� O
'
'
'
'
'
'
'
OD
N
Ln
O
(Wn
A
N
A
N
NO
�'
00
Z O
w v n
m Fu o u N D ,� �Q d 6Cy ' PROPRIETARY AND CONFIDENTIAL Z pZ
cn 1 rn f0 ? I W -n . 0 : 3 . THE INFORMATION CONTAINED IN Q �
o -0_ j o y c y y THIS DRAW ING IS THE SOLE Z c W co O a g
Zcb -00 �_ �( �p10 a O;o= PROPERTY OF CUSTOM WINDOW��_ (^�
z o 2 n= z m D can c �`) ' D �9 m* m 2? SYSTEMS, INC. ANY �s r n o D
o m �'T co Z v �:O O �:: REPRODUCTION IN PART OR AS A W C D m e^
o 2 � C � 1 (n r D o m :2 .z '� �' Y � WHOLE WITHOUT THE WRITTEN D D n � H�
Im C) w a N m-.,,' • ,�C� PERMISSION OF CUSTOM WINDOW n ; p
o co m m ��i�FFq'* ti3 `� SYSTEMS, INC IS PROHIBITED.
�f4jgptt�
x
767-004L
FIT
IuLIl�
-USE WOOD SCREW SIZE (910 OR #12), SPECIFIED IN WINDOW UNIT APPROVAL DOCUMENT
7/16"
11 ..
1 1/4'
1111
1/2'
1061�9
1/16
1116"
V16'
MULLION INTERIOR
DRIP CAP S-1895
- - COVER S-6018 - _
FLANGE ADAPTER S-1896
LIII I
TOP VIEW
2 13/16' 1/8'
I
3" MULLBAR H-1758
1 3/16'
7
118"
MULLION CLIP S-1897
U A
SCORE, BEND AND BREAK
TO REMOVE FIN FOR FRAME
ATTACHEMENT TO MULL BAR
DETAIL A
TYP. FIN FRAME 3:1
NOTE: ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED.
m 1/4'
14
2 1/4'
L 1/8'
4 7/8"�
F-1522 - 013
NEW CONSTRUCTION / FIN INSTALLATION
FRAME TYPE
OPENING
"T" MULLBAR I
(F-1522-XXX
NEW
F-1522-013
FLANGE
RETRO
F-1522-006
FIN
NEW
F-1522-013
RETRO
F-1522-013
NEW
NOT RECOMMEI
BOX
RETRO
F-1522-006
IP- "L" MULLBAR CLIP
(F-1767-XXX)
F-1767-001
F-1767-001
-{ 7/16"
3/8' -
2 7/1'
1 11/16" (1 7/8")
1 5/16' (2 1/4")
F-1767-004(U
F-1767-001
F-1767-001
WINDOW SYSTEMS 8
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
W W W.CWS.CC
3" PVC
MULL BAR
NON -IMPACT
a z 3 ¢zo
F ❑WOw-jo WwOpo
oz
o z0§>-0w�m
LL .rw�z�3gx
z zxm¢xw00
O O(DO-za-P-c'd
�?
F-u-Mo U-
Of m�O}FF~a-
i R ww
ZowwO-ow -- a xa ofO�m'
O w1-o uam
= a-_w3w
i►LY
318'
T
1
2 3116" .
1/8"
L F--4 7/8'
F-1522-006
RETRO / FLANGE CLIP
%ry
9/26/2017
LUCAS A. TURNER', P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH.941-380-1574
BOM AND EXTRUSIONS
RS 04/13/09
VG #: REV_
CWS-430 C
'ALE' SHEET
1:2 4 OF 10
NOTE: IF USING CLIPS WHICH REQ. FOUR (4) ANCHORS PER END (REFER TO
SHEET 2), THE MIDDLE HOLE (CIRCLED) MUST BE USED WITH ANY OTHER
HOLE AS REQ'D PER EDGE DISTANCE.
"L• ANGLE 3• MULL CLIP, FIN (LEFT) F-1767-004L
OUTSIDE
•L• ANGLE 3• MULL CLIP, FIN (RIGHT) F-1767-004R
FRAME TYPE
OPENING
"T" MULLBAR CLIP
"L" MULLBAR CLIP
(F-1522-XXX)
(F-1767XXX)FLANGE
NEW
F-1522-013
F-1767-001
QmtzffEd
RETRO
F-1522-006
F-1767-001
1900 SW 44TH AVE.
NEW
F-1522-013
F-1767-004(L&R)
OCALA, FLORIDA 34474
I
FIN
WWWCWS.CC
RETRO
F-1522-013
F-1767-004(L&R)
NEW
NOT RECOMMENDED
F-1767-001
BOX
3" PVC
RETRO
F-1522-006 I
F-1767-001
r-23/4- \J 21/4•
_-1
(2 314•)
7/16' THRU(TYP)-
1@'
MULL BAR
NON -IMPACT
a
? azo
0
w
zpz cc~zW
U.
I-w§z�3'2x
z
O
zx2¢wwop
pm pp a
�aF-ta
[n ?
re
�?< ow -mop
�pFFFpZ
2 7/16•
F
0w��}��i0�
to W p 0-
1
Z a
FF& WSW'
a l _D__
1/4• THRU (TYP)
•L• ANGLE 3' STANDARD MULL CLIP - F-1767-001
7
9/26/2017
LUCAS A. TURNER, P.E.
FL PE # 68201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
SHEET DESCRIPTION:
EXTRUSIONS
DRAWN BY: DATE:
RS 04/13/09
DWG#: REV_
CWS-430 C
SCALE: SHEET
1:2 5 OF 10
� U SEAL BEHIND FLANGE
SEAL BEHIND FLANGE O PRIOR TO ATTACHING = APPLY SEALANT ALONG FULL ,
PRIOR TO ATTACHING TO MULLION LENGTH OF WINDOW FRAME
TO MULLION Q 2I —O2 GROOVE PRIOR TO ATTACHING 2
9 1 g !I 1 COVER 1
I 11
11 11 I 11
FIN MUST BE REMOVED p O
WHERE WINDOWS
CONNECT TO MULL �
i
I
I I
HORIZONTAL MULL BAR SECTION �1 HORIZONTAL MULL BAR SECTION 1 %AIVERTICAL HORIZONTAL MULL BAR SECTION
6 FLANGE FRAME WINDOW I 6 FIN FRAME WINDOW I 6 BOX FRAME WINDOW
i
— — — — — — — — — — — — — — — — — — -- — — J — — — — — — — — — — — — — -- — — — — — — — — — — — —
APPLY SEALANT ALONG FULL
11 1 2 1 11 1 2 LENGTH OF MULLBAR GROOVE
PRIOR TO ATTACHING DRIP
i ADAPTOR
FIN MUST BE REMOVED
WHERE WINDOWS 1
CONNECT TO MULL I g
0 0 o
i DETAIL A
I � I
SEAL BEHIND FLANGE I
SEAL BEHIND FLANGE 10 (SEE DETAIL B) I PRIOR TO ATTACHING 10 (SEE DETAIL B)
PRIOR TO ATTACHING TO MULLION - I APPLY SEALANT ALONG FULL
TO MULLION i I LENGTH OF MULLBAR GROOVE
PRIOR TO ATTACHING FLANGE i
�1VERTICAL MULL BAR SECTION I �ZVERTICAL MULL BAR SECTION I ADAPTOR 1
6 FLANGE FRAME WINDOW I s FIN FRAME WINDOW I"
I ' L
i r
i
I 10
I DETAIL B
I I
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
W W W.CWS.CC
3" PVC
MULL BAR
NON -IMPACT
Q Z ¢Z�
P OWO WHO'
O
W ZOZ M==IW_-
O amp
ti F-W ZI-3:;E_
-Z Z2m¢wWOO
O ol-0cn�Oarrnn-
rn ?
Z 00--.3 -j0-
¢ H?LLg0OWZ
1�owF=I=-O-
¢ I- ZC6
I! OOww wvi0m
�" rn W O J (A a
I-
a:aW=�
�a�
a a �
z�
9/26/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
SECTION VIEWS
MULLS
RS 1 04/13/09
CWS-430 C
ALE' SHEET
1:2 6 OF 10
TOP VIEW
FIN FRAME
-- - -- 5'M000BAR_(H=1760)- --
(SEE SEPARATE APPROVAL FOR
APPROPRIATE DP CHARTS)
SEE NOTE 1
I YI I 111 U SEE NOTES 1& 2
(2 EAJCUP)
5' HORIZ. TO 3' VERT. MULLBAR SECTION
7 FLANGE FRAME WINDOW
MULLBAR (H-1759)
EE SEPARATE APPROVAL FOR
'PROPRIATE DP CHARTS)
,TE 1
=S1&2
(2 EA./CLIP)
C 4' HORIZ. TO 3' VERT. MULLBAR SECTION
(FLACTGE FRAMF WINDOW
SECTION VIEW A -A
=E NOTE 1
E NOTES 1 & 2
-A.ICLIP)
�3' HORIZ TO 3' VERT. MULLBAR SECTION
�FLANG FRAME WINDOW
NOTES:
1. SLIDE CLIP INTO LOCATION AND SECURE WITH REM 19 (OTY 2), AS SHOWN ABOVE.
2. PRE -DRILLED HOLES (THRU HN CLIP 1897). BY THE INSTALLER,
MAY BE LOCATED AS NEEDED WHILE MAINTAINING A MINIMUM CLIP EDGE DISTANCE
OF 9132' AND A MINIMUM CENTER TO CENTER SPACING OF 112'.
3. THE ABOVE SECTIONS APPLY TO ALL MULLBAR-TO-MULLBAR CONNECTIONS,
REGARDLESS OF ORIENTATION (i.e., HORIZONTAL OR VERTICAL). THE FULL LENGTH
MULL MUST BE THE SAME DEPTH, OR GREATER, THAN THE INTERSECTING MULL.
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
WWW.CWS.CC
3" PVC.
MULL BAR
NON -IMPACT
I—
z ¢z�
ow0 avow
Z
IIIzoz
o
WJo
oft?
¢v1—>oo:�m
It
Z
I-W�ZI-��x
zxm<wwoo
0
0
01-0 ¢xFW
0cn7 -z Q-P U)E
Z
� p—ZjU�
zowzDo
Q
Y
'
¢,Q�}�U�,IOxOZ
Ia-
O0QF>����
Zcow�O_jaiF
d 0 co
CC
0.
x~a Q�wul
9/26/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
IEET DESCRIPTION:
SECTION VIEWS
MULL INTERSECTIONS
LAWN BY: DATE:
RS 04/13/09
VG #: REV_
CWS-430 C
:ALE: SHEET
12 7 OF 10
0
TRANSOM OVER TWIN
VERTICAL MULLION
" OPENING SIZE
TRANSOM OVER TRIPLE
VERTICAL MULLION
7
L
3 I II
+I nPFNIN(: C17F L
TWIN
VERTICAL MULLION
i
LI
F-- OPENINGSIZE—
F
C�
J
1
TRIPLE
VERTICAL MULLION
OPFNIKlr C17P
HORIZONTAL MULLION
w
N
z ISINGLE1
Z TWIN
w OR
o ITRIPLE1
UNITS
BELOW
I-- MULL LENG
NOTES:
1. AT MULLION LOCATION, ATTACH WINDOW UNIT(S) TO MULLBAR THRU FRAME AS SPECIFIED IN WINDOW UNIT APPROVAL DOCUMENTS. IF ALUMINUM ATTACHMENT IS NOT SPECIFIED IN THE WINDOW UNIT APPROVAL
DOCUMENTS, FOLLOW THE ANCHOR SPACING AS INDICATED IN THE WINDOW APPROVAL FOR ATTACHMENT TO WOOD SUBSTRATE, USING A HEX WASHER HEAD TEK SCREW OF THE SAME SIZE (#10 OR #12) AS THE
WOOD SCREW INDICATED IN THE WINDOW APPROVAL. TEK.SCREWS SHALL BE LONG ENOUGH TO ENSURE THREE (3) THREADS OF PENETRATION BEYOND THE INSIDE WALL OF MULLBAR.
2. MULL CLIP INSTALLATION ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 9.
3. ALL MULL CLIP INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED
WOOD MUST BE PROTECTED TO PREVENT REACTION.
4. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE
MINIMUM SPECIFIED IN TABLE 1, SHEET 9.
5. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE -1X BUCKS
ARE OPTIONAL.
6. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED AS INDICATED BY THE PRE -DRILLED HOLES AS SHOWN IN THE CLIP LAYOUTS ON SHEETS 4-5.
7. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE,
SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET, SHEET 9. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED.
8. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS:
FMA/AAMA 100(FIN WINDOWS), FMA/AAMA 200(FLANGE WINDOWS), FMANVDMA 250(BOX WINDOWS), FMA/AAMANVDMA 300(EXTERIOR DOORS)
Qu�mo
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
W W W.CWS.CC
3" PVC
MULL BAR
NON -IMPACT
Q
F-
? Q Z 3.
❑WO QW00
Z
WJo u0
0
zz ZwZ>-O��m
W
Z
F--W�ZF- :2H!
zmm<wwOO
0
Orn�zG-Pcoa.
Z
Z0 Z) Z7Uu]
Q<�O}}FFFO_
F-
DOF>- 3:0Ui
2
LL
Z CO w 0 _j A F-
a
o
_~� W a. �Wul
- EL
F_-°=—X-- a--
/,_
9/26/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
CONFIGURATIONS AND
ANCHORAGE NOTES
RS 1 04/13/09
CWS-430 C
.ALE: SHEET
1:1 8 OF 10
SEALANTALONG
OUTSIDE EXPOSED
EDGE BY INSTALLER
PERIMETER SEALANT —
BY INSTALLER
INSIDE AND OUT
SUBSTRATE BY -OTHERS
SEE TABLE 1
MIN. EDGE DIST.
SEE TABLE 1
WINDOW SYSTEMS
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
www.cws.cc
3" PVC
MULL BAR
NON -IMPACT
RETRO FIT "L' ANGLE MULL BAR CLIP
MULL BAR CLIP TWO REQ'D PER EACH END OF MULL Q Z ?�0wo Q Z
Inwon
- MULL BAR .. _ MULL BAR Z W _j 0 Q F-
W
u u o QcoZ>Om5co
li FW2'ZI-�i22
INSTALLATION ANCHOR INSTALLATION AN U
SEE TABLE 1 �� SEE TABLEA 0 Z- n- Z F j U)
ADD STRUCTURAL ELEMENTS = -1- _ = ADD STRUCTURAL ELEMENTS Z 0 O U U 7 U
' AS REQ'D TO MAKE LEVEL FOR SEALANT ALONG - - _ - - _ AS REQ'D TO MAKE LEVEL FOR Q tL O O W Z
MULL BAR OUTSIDE EXPOSED — MULL BAR ¢ O W F H Z -
EDGE BY INSTALLER 2 U Uj
PERIMETER SEALANT - W O n n p W W
MIN. EMBEDMENT BY INSTALLER MIN. EMBEDMENT w Z d O ~
SEE TABLE 1 INSIDE AND OUT SEE TABLE 1 - - p W F 0 W =
SEE TABLE IBY OTHERS
%Dl' VERTICAL SECTION
9 TYPICAL FLANGE (RETRO FIT) ANCHORAGE
HEAD AND JAMBS SIMILAR FOR FLANGE INSTALLATION
TABLE 1: APPROVED MULL CLIP INSTALLATION FASTENERS
SUBSTRATE TYPE
ANCHOR TYPE
MIN. EMBEDMENT
MIN. EDGE DIST.
CONCRETE (2.0 KSI MIN.)
3/16" ITW TAPCON
1"
3"
CONCRETE (2.85 KSI MIN.)
3116" ELCO ULTRACON
1-3/4"
1"
HOLLOW or GROUT -FILLED CMU (ASTM C-90)
1/4" ELCO ULTRACON
1-1/4"
2-1/2"
2X MIN. SOUTHERN PINE (G=0.55)
3/16" ITW TAPCON
1-3/B"
7/8"
OR ELCO ULTRACON
2XMIN. SOUTHERN PINE (G=0.55)
#10 WOOD SCREW
1-3/8"
7/8"
16 GAUGE (0.060") MIN. STEEL STUD
#10-16 HILTI KWIK-FLEXOR ITW
FULL THREAD
(33 KSI YIELD MIN)
TEKS SELF -DRILLING SCREW
THRU 0.060"
7/16'
1/8" ALUM. (6063-T5 MIN.) OR
#10 GRADE 5 SELF -TAPPING /
FULL THREAD
1/8" STEEL (33 KSI MIN.)
DRILLING SCREW
THRU 0.125"
7/16"
"-1 MIN. EDGE DIST.
SEE TABLE 1
rE1 VERTICAL SECTION
9 TYPICAL FLANGE ("L" ANGLE) ANCHORAGE
HEAD AND JAMBS SIMILAR FOR FLANGE INSTALLATION
NOTES:
1. BOX FRAME MULL INSTALLATION SIMILAR TO FLANGE FRAME.
2. SILL STOOL MUST BE FLUSH AGAINST INSIDE OF MULLED WINDOWS
AFTER INSTALLATION.
3. RECESS RETRO MULLION CLIP 3/8" MAX. FOR CLEARANCE OF WINDOW
UNIT AS NEEDED.
4. FOUR (4) ANCHORS REQUIRED PER "T- MULL CLIP, SEE SHEET 2.
TWO (2) or THREE (3) ANCHORS REQUIRED PER "L" MULL' CLIP, SEE SHEETS 2-3.
5. SEAT MULLION TIGHT TO MULL CLIP.
6. FOR ANCHORAGE DETAILS FOR THE WINDOW, REFER TO THE WINDOW
SPECIFIC INSTALLATION DETAILS.
r.-.-_
9/26/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
HEET DESCRIPTION:
INSTALLATION DETAILS
FLANGE
RAWN BY: DATE:
RS 04/13/09
WG#: REV.:
CWS-430 C
GALE` SHEET
1:2 9 OF 10
RETRO FIT
MULL BAR CLIP
MULL BAR
— L
` - - INSTALLATION ANCHOR
d I SEE TABLE 1. SHT 9
SEALANT ALONGE
-
SEALANTALONGE -
OUTSIDE EXPOSED
OUTSIDE EXPOSED
EDGE BY INSTALLER
EDGE BY INSTALLER
EXTERIOR FINISH-- _
MIN _EMBEDMENT -
_ EXTERIOR FINISH
BY OTHERS
," ot..
_ ___ _ _
SEE TABLE 1, SHT 9
BY OTHERS
PERIMETER SEALANT
PERIMETER SEALANT -
BY NSTALLER
BYINSTALLER
INSIDE AND OUT
INSIDE AND OUT
SUBSTRATE BY OTHERS
SUBSTRATE BY OTHERS
SEE TABLE 1, SHT 9
^
SEE TABLE 1, SHT 9
MIN. EDGE DIST.
SEE TABLE 1, SHT 9
FF�
VERTICAL SECTION
10.
TYPICAL FIN (RETRO FIT) ANCHORAGE
HEAD AND JAMBS SIMILAR FOR FIN INSTALLATION
'L" ANGLE CLIP-
E= PER EACH END OF MULL
MULL BAR
it ?:
fLO
INSTALLATION ANCHOR
I� SEE TABLE 1, SHT 9
EDGE DIST.
VERTICAL SECTION SEE TABLE 1, SHT 9
10 TYPICAL FIN (-L- ANGLE) ANCHORAGE
HEAD AND JAMBS SIMILAR FOR FIN INSTALLATION
V- IuYW/o I]'I-I�
WINDOW SYSTEMS I\ �/I
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
WWW.CWS.CC
3" PVC
MULL BAR
NON -IMPACT
a
P
z �: QZ�:
owo wwoo
Zoz wMw
O_
LL
Z
1-w ZF-�ig2
Zmm<wwpp
o
O
OI-o a=Fw
Um,z0-I-mD-
Q
OZpw D -
>_
O LL
flowCmoZ
I~L1
W(AW
wa p-iWF-
co
p
wl-o wO w>_
w In
- ---
-°
- ~ a- a
9/262017
LUCAS A. TURNER, P.E.
NOTES:
FL PE # 58201
1239 JABARA AVE.
1. SILL STOOL MUST BE FLUSH AGAINST INSIDE OF MULLED WINDOWS
NORTH PORT, FL 34288
AFTER INSTALLATION.
PH.941-380-1574
2. RECESS RETRO MULLION CLIP 3/8' MAX. FOR CLEARANCE OF WINDOW
SHEET DESCRIPTION:
UNIT AS NEEDED.
INSTALLATION DETAILS
FIN
3. FOUR (4) ANCHORS REQUIRED PER T MULL CLIP, SEE SHEET 2.
TWO (2) or THREE (3) ANCHORS REQUIRED PER "L" MULL CLIP, SEE SHEETS 2-3.
DRAWN BY:
DATE:
RS
04/13/09
4. SEAT MULLION TIGHT -TO MULL CLIP.
DWGp:
REV.:
5. FOR ANCHORAGE DETAILS FOR THE WINDOW, REFER TO THE WINDOW
CWS-430
C
SPECIFIC INSTALLATION DETAILS.
SCALE:
SHEET
1.2
100F 10