Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL WINDOWS MULLIONSFlorida Building Code Online I Page 1 of 3 i 0CANNED • ` 0 ® e . i BY L t• 5t Lucie County 2-3 BCIS Home Log In User Registration Hot Topic � Submit Surcharge I Stats & Facts Publications Contact Us • BCIS Site Map I Links Search bprodU=ApprovalC�tStt����ER: lic User G�'tTaaWr�0.itn Product Aooroval Menu > Product or Aoolicatlon Search > Application List > Application Detail + i •' FL # FL5777-R5 Application Type Revision Code Version 2017 Application Status Approved Comments Archived ❑ Product Manufacturer Custom Window Systems Inc. Address/Phone/Email 1900 SW 44th Avenue Ocala, FL 34474 (352)368-6922 Ext291 jlathrop@cws.cc Authorized Signature Kevin Pine i kpine@cws.cc Technical Representative I Jay Lathrop Address/Phone/Email 1900 SW 44th Ave Ocala, FL 34474 (352)368-6922 Ext291 jlathrop@cws.cc Quality Assurance Representative Arturo Monteverde Address/Phone/Email 1900 SW 44th Ave Ocala, FL 34474. (352)368-6922 Ext221 amonteverde@cws.cc Category Windows Subcategory I Mullions Compliance Method I Evaluation Report from a Florida Registered Architect or a Licensed i Florida Professional Engineer i ❑ Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report .Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) I i Equivalence of Product Standards Certified By Lucas A. Turner PE-58201 Keystone Certifications, Inc. 07/21/2020 Steven M. Urich, PE R'l Validation Checklist - Hardcopy Received FL5777 R5 COI EvalReport244C.odf Standard AAMA 450-10 AAMA/WDMA/CSA 101/I.S.2/A440 TAS 202 Florida Licensed Professional Engineer or Architect FL5777 R5 Eauiv FL5777 Eauivalencv.ndf Year 2010 2005 1994 Ffe Copy https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgs%2bZ 1 jLJBT... 8/27/2018 Florida Building Code Online Page 2 of 3 Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved I I i I Method 1 Option D 09/29/2017 09/29/2017 10/02/2017 12/12/2017 FL # IModel, Number or Name Description 5777.1 Adjustable (Angled) Mull Adjustable Mullion for Alum. and PVC Windows. Limits of Use Installation Instructions Approved for use in HVHZ: No FL5777 R5 II CWS-243C.odf Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Not for use in HVHZ. See Mullion Product Evaluation FL5777 RS AE EvalReport243C.pdf Report for complete list of Limitations and Conditions. Created by Independent Third Party: Yes 5777.2 CWS-1758 Mull Bar I 3" Mull Bar for PVC Windows. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL5777 R5 II CWS-430C.pdf Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See Mullion Product Evaluation Report for complete FL5777 R5 AE EvalReport430C.Ddf list of Limitations and Conditions of Use. I Created by Independent Third Party: Yes 5777.3 CWS-1759 Mull Bar I 4" Mull Bar for PVC Windows. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL5777 R5 II CWS 431C.pdf Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A I Evaluation Reports Other: See Mullion Product Evaluation Report for complete FL5777 R5 AE EvalReport431C.pdf list of Limitations and Conditions of Use. ICreated by Independent Third Party: Yes 5777.4 CWS-1760 Mull Bar 5 1/2" Mull Bar for PVC Windows. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL5777 R5 II CWS-432C.odf Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See Mullion Product Evaluation Report for, complete FL5777 R5 AE EvalReoort432C.Ddf list of Limitations and Conditions of Use. Created by Independent Third Party: Yes 5777.5 CWS-1950 Mull Bar 2" Mull Bar for Aluminum Windows. Limits of Use Installation Instructions Approved for use in HVHZ: No FL5777 R5 II CWS-245C.odf Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -N/A Evaluation Reports Other: Not for use in HVHZ; See Mullion. Product Evaluation FL5777 R5 AE EvalReport245C.pdf Report for complete list of Limitations and Conditions of Use. Created by Independent Third Party: Yes 5777.E CWS-1952 Mull Bar 3" Mull Bar for Aluminum Windows. Limits of Use Installation Instructions Approved for use in HVHZ: No FL5777 R5 II CWS-244C.odf Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -N/A Evaluation Reports Other: Not for use in HVHZ; See Mullion Product Evaluation FL5777 R5 AE Eva I Repo rt244C, Ddf Report for complete list of Limitations and Conditions of Use. Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 i The State of Florida Is an AA/EEO employer. Coovriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement htts://www.floridabuildin .or / r/ r_a dtl.as x? atom=wGEVX wtD s%2bZ1'LJBT... 8/27/2018 P g g P P PP_ P P• Q Q J Florida Building Code Online Page 3 of 3 Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please Approval hers.. Product Approval Accepts: �m in , eCli Credit Card Safe 1 https://www.floridabuilding.org/pr/P _app_dtl.aspx?param=wGEVXQwtDgs%2bZ1jLJBT... 8/27/2018 ANCHOR CLIP 3" PVC MULL BAR - NON -IMPACT SHOWN W/DIFFERENT OPTIONS G F E (D) IL ANCHOR CLIP 10 10 9 9 EXAMPLE HORIZ/.VERT. MULLION FOR SECTION VIEW ONLY TABLE OF CONTENTS GENERAL NOTES & ELEVATIONS...............1 DP CHARTS.................................................2-3 BOM & EXTRUSIONS.....................................4 EXTRUSIONS.................................................5 SECTION VIEWS.........................................6-7 CONFIGURATIONS & ANCHOR NOTES INSTALLATION DETAILS ..........................9-10 ANCHOR CLIP GENERAL NOTES- 1.1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE FLORIDA BUILDING CODE (FBC), CURRENT EDITION. 1900 SW 44TH AVE. 2. CONFIGURATIONS (SEE SHEET 2): VERTICAL OR HORIZONTAL. OCALA, FLORIDA 34474 W W W.CWS.CC 3. SEE MULLION CHARTS FOR MAX. DESIGN PRESSURES AND LENGTH. (REFER TO SHEETS 2-3) 3" PVC 4. ANCHORAGE: THE 33 1/3 % STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. SEE SHEETS 9-10 FOR ANCHOR DETAILS. WINDLOAD MULL BAR DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. NON -IMPACT 5. NOT APPROVED FOR IMPACT RESISTANCE. IMPACT PROTECTIVE SYSTEM IS REQUIRED IN WIND BORNE DEBRIS REGION. ¢ Z C O 6. DESIGN PRESSURE OF MULLED UNITS SHALL BE CONTROLLED BY THE LESSER Z Z w w o WHO* Z w DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL WINDOW UNITS. w z 0 z a - - am->-Ow�m 7. DESIGN PRESSURES AND INSTALLATION DETAILS SHOWN IN THIS DOCUMENT LL Z _ z W a a, W 0 p APPLY ONLY TO THE MULLION. WINDOWS MUST BE APPROVED UNDER SEPARATE 0 O F- 0 �j ¢ = f- fY l- a APPROVAL. 0 Z- y- Z D 8. RESPONSIBILITY OF SELECTING FENESTRATION PRODUCTS TO MEET ANY APPLICABLE Q � - Z a U) O 0 a 0 LOCAL LAWS, BUILDING CODES, ORDINANCES OR OTHER SAFTEY REQUIREMENTS RESTS SOLEY WITH THE Cltw- F F_ Z ARCHITECT, ENGINEER OF RECORD, BUILDING OWNER OR CONTRACTOR. F 0_fi} O Oa w_ 0O w U) w 9. SINGLE UNITS TO BE MULLED ARE NOT LIMITED TO THOSE SHOWN IN THIS It p z-a w I=- O a - DRAWING. SINGLE UNITS TO BE MULLED TOGETHER MUST BE MANUFACTURED BY a rn a K � -CUSTOM-WINDOW SYSTEMS;-INC.-AND-MUST-BE-MADE-OUT OF VINYL PVC -OR - -� aw EXTRUDED ALUMINUM. 10. VERTICAL MULLED UNITS MAY BE MULLED INDEFINITELY AS LONG AS THE SINGLE UNIT WIDTH AND HEIGHT ARE NOT EXCEEDED, AND MULLIONS ARE ANCHORED AS SHOWN .�����t�ORE41�rrr4 ��cEWSF HERE IN. 11. HORIZONTAL MULLION SHALL EXTEND THE ENTIRE WIDTH OF THE MULLED UNIT. �;� No 58201 .-P VERTICAL MULLION IS USED TO MULL SIDE BY SIDE UNITS TOGETHER. = * E ANCHOR CLIP I O II O I X I I II X I I 4 4 nucuna ri io EXAMPLE VERTICAL MULLION FOR PVC WINDOWS FOR SECTION VIEWS ONLY Lucas Turner 2017-09-28 07:10+20:00 X� 9/26/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 GENERAL NOTES AND ELEVATIONS IRS 1 04/13/09 CWS-430 C uE SHEET 1:25 1 OF 10 0 i n L 'a z G) cn T IYIULL LCIVU I fl I•� MULLLENGTH o ny� z F Z 6] 3 z y m r L o z l r— MULL LENGTH --I O < m m z z =I O n N .A -a m cm T r 0 z r— OPENING SIZE-�i I O �1 c r mZLO�Z O m 0���—M.- 0 zz v MULL LENGTH (in.) z u z 0 a m acne _ W m D -4 m O G cn W W N N u o g O N a W VI n W A OC A N W u (� O D ,il A� OHO Oo Oo Qr O A O Or W A W A A O I7 O z V O� mm cyiO1 -I(n .I o 0 :0 '0 �0 C ca � .. ' V W N N N m W O W V A N m -� m N V m W W O W f V N 0 N 0 N 0 N 0 N 0 N 6 N 0 W w o m 3 W !� co U r > w 0 �m cm V C7 N T N V A A-4 V O A W 0 0 0 0 0 O z1 O z O 0 �' (1 m0 °o^ r 0 2 O Oo T v C m N O V -I Z ,I -� f/> _ V N O NJN W c0 W W W (0 A W m (0 m c0 W CO A N 0 0 0 0 0 0 't np 0 D Z X 0 nr F W Z o O O � X O _ < I --• N N m N c0 W m A W U1 W m N V W W m (D W O o N N 0 N 0 N 0 N O N V r? O m z m O 0 A W W A m m V Co (O o - N N m 0 -n rz O m W A m 0 O O ON Wm CZr Z 0v0 ZC O .Zl m m N N wWNm 1-4 N V W c0 ON w w o NO o W cO A Z W X m mm O c O r r 0 m 0 XI I N I")N W A A Ul m V V W (0 NO NO V fC O Z IT! m O W W A N W m m A (0 OD cJl � CA-{ O= 0 Q n z V (11 _ W 0) N N A N NO a mCzC � m -N-� -W+ w(AI W (WO OWo W z Z C O zi • I W N O N A N c0 W m A N A f0 m V m m m W V V W W (O N O N W V X f!1 D m O -.� P J 2 r m � ;u n V c0 (N.l V CO rn (�rvr�i m m V V COW W� c0 . m two A' �cnw(0a)(D W ;u 00 m W ONl N V W !N W N cm0 A (O w O r = � N m m N O N A W 0 W A O V A m W m A m CJ V m W W nl u W 00, ,'c07 V O O) C V 1 n m W N CO N V A .A O CA N Owl A r r W IT! c o (n ao z r 0 _ N N W W A A m Ln m m V c0 0 m W m O m N (D N W N W W n 0 A C Z1 (� A -• N N W W A A (Jl m m j W C# m a7 A m N W V W V N W N 'a O W m T n m W N C. O cn ,pp A cA0 N ((77ll V m T O CX C m fn m . O a m m m m N z N n tpUrn{{{{I ,,,,����� lF: it �: g : (P . PROPRIETARY PROPRIETARY AND CONFIDENTIAL * O m THE INFORMATION CONTAINED IN o D -u z z$ n (o r y ° +' ��r .�' z „9' h rO.o n , THIS DRAWING IS THE SOLE Z C W T ulp$ g� n o 2 V 2 z -�Dm1 W O W co D c o.�o 3z r c l _ yl m '4 m 2j rn "- PROPERTY OF CUSTOM WINDOW SYSTEMS, INC. ANY r- r '� 0 z m n c D D 0 _ o m ' V N 1 m co Z r �r O O o 'n: ' :9 *+ REPRODUCTION IN PART OR AS A W C Ci m' o^ H ON n C o m aco ��2 Cy,� �i�C'ti�R�,r�,�'��p` WHOLE WITHOUT THE WRITTEN PESYSITEMS, > D A c m NCCIS PROHIBITED. MULL LENGTH-1 O Z 0 En N L LI- ,., ���u. ,,,--1 O v Z 0 rh N F--- MULL LENGTH --I m� ;oO DK r0 c m O -S1 Z Z �CD �3 r0 3m C A zv m m o z D r_ G1 N C Z N r LZ L F-- MULL LENGTH I O m m m z i z GI D A N N rT �r cm r T t O Z F� OPENING SIZE --I I L O r wc-4 to mz� Z r-O -ut- ZOZ -I m O �) m Z- 3 � _� _m c L ° Z z o MULL LENGTH (in.) o mmrn� Zm 9 rq o a n a a 0 ` ito � n 00 N O) O A W N Q' O A O O) N W W J •+ W W �J A O)�� ��A — c) pp A OD F A ` X m -+ �! W N N N O) W O W V A N O) O) N V Of W co O _ N _ N _ N _ N N _ N _ N N W O r w n m 0 c- N•• rn co) _ cn .1.J < X C D r�- r W O O O O O do O .Z% -Im �n ZZ Oo (n NO)O V A O O O O O41 c$% ZZm co r p .. D co rmN = O W N NN N 0 -n O 0 I D W (D (D 0 0 0(D C) 0 0 X D�p0 rD DZ OC O r- O Z X N N N W A N O) V W O N N N N N N N W m O Z W Ut W W N W O) co O O O O O O V O o 'X 2 -n O D D) W N A N V W N W (D A (D W 07 V (O C V V co (O m O O O C. O W i Z m0 cn m c QJ Z z r n L7 c W O.'n m ' V N 1IVV N Ul W O W O) A W N Q) V (O O N N N N N O m 3 0 'm'I _ (T N --� co O O O O O O X C m m O 3 m o g v p m A N N N W A A (J1 Q) aV W NO NO V CmZ C m 2 O O m O) CDW co A N co O) O) W (D O O ON CA Z 0 O V 'u m O) V (O N N N N N Z C O Vt O O) (D (n N N V N O O O O O Z c r '� r N r o O O A N V N CO CO v�0 pr O) coN OW) (AO M O O O C V= O 7 O �C fTl V (D W V A (WD m A W 0 O N N N N O O co O O O O W G) D f p C _ N N W W A Vt W V O -� N N N O r= O O O W r O V _ O) O A O A O v (�D O (07) ' O O O o W mr p_ N W (D M m En O O) W N OD N V A O) O) (D M Ul mO 0 A m X en OD • -� O) O CD N W W A O N N N y O O O O O A O o O W O) (D A W N W M V V O 01 O N C Z � O ' ' ' ' ' ' ' OD N Ln O (Wn A N A N NO �' 00 Z O w v n m Fu o u N D ,� �Q d 6Cy ' PROPRIETARY AND CONFIDENTIAL Z pZ cn 1 rn f0 ? I W -n . 0 : 3 . THE INFORMATION CONTAINED IN Q � o -0_ j o y c y y THIS DRAW ING IS THE SOLE Z c W co O a g Zcb -00 �_ �( �p10 a O;o= PROPERTY OF CUSTOM WINDOW��_ (^� z o 2 n= z m D can c �`) ' D �9 m* m 2? SYSTEMS, INC. ANY �s r n o D o m �'T co Z v �:O O �:: REPRODUCTION IN PART OR AS A W C D m e^ o 2 � C � 1 (n r D o m :2 .z '� �' Y � WHOLE WITHOUT THE WRITTEN D D n � H� Im C) w a N m-.,,' • ,�C� PERMISSION OF CUSTOM WINDOW n ; p o co m m ��i�FFq'* ti3 `� SYSTEMS, INC IS PROHIBITED. �f4jgptt� x 767-004L FIT IuLIl� -USE WOOD SCREW SIZE (910 OR #12), SPECIFIED IN WINDOW UNIT APPROVAL DOCUMENT 7/16" 11 .. 1 1/4' 1111 1/2' 1061�9 1/16 1116" V16' MULLION INTERIOR DRIP CAP S-1895 - - COVER S-6018 - _ FLANGE ADAPTER S-1896 LIII I TOP VIEW 2 13/16' 1/8' I 3" MULLBAR H-1758 1 3/16' 7 118" MULLION CLIP S-1897 U A SCORE, BEND AND BREAK TO REMOVE FIN FOR FRAME ATTACHEMENT TO MULL BAR DETAIL A TYP. FIN FRAME 3:1 NOTE: ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. m 1/4' 14 2 1/4' L 1/8' 4 7/8"� F-1522 - 013 NEW CONSTRUCTION / FIN INSTALLATION FRAME TYPE OPENING "T" MULLBAR I (F-1522-XXX NEW F-1522-013 FLANGE RETRO F-1522-006 FIN NEW F-1522-013 RETRO F-1522-013 NEW NOT RECOMMEI BOX RETRO F-1522-006 IP- "L" MULLBAR CLIP (F-1767-XXX) F-1767-001 F-1767-001 -{ 7/16" 3/8' - 2 7/1' 1 11/16" (1 7/8") 1 5/16' (2 1/4") F-1767-004(U F-1767-001 F-1767-001 WINDOW SYSTEMS 8 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CWS.CC 3" PVC MULL BAR NON -IMPACT a z 3 ¢zo F ❑WOw-jo WwOpo oz o z0§>-0w�m LL .rw�z�3gx z zxm¢xw00 O O(DO-za-P-c'd �? F-u-Mo U- Of m�O}FF~a- i R ww ZowwO-ow -- a xa ofO�m' O w1-o uam = a-_w3w i►LY 318' T 1 2 3116" . 1/8" L F--4 7/8' F-1522-006 RETRO / FLANGE CLIP %ry 9/26/2017 LUCAS A. TURNER', P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH.941-380-1574 BOM AND EXTRUSIONS RS 04/13/09 VG #: REV_ CWS-430 C 'ALE' SHEET 1:2 4 OF 10 NOTE: IF USING CLIPS WHICH REQ. FOUR (4) ANCHORS PER END (REFER TO SHEET 2), THE MIDDLE HOLE (CIRCLED) MUST BE USED WITH ANY OTHER HOLE AS REQ'D PER EDGE DISTANCE. "L• ANGLE 3• MULL CLIP, FIN (LEFT) F-1767-004L OUTSIDE •L• ANGLE 3• MULL CLIP, FIN (RIGHT) F-1767-004R FRAME TYPE OPENING "T" MULLBAR CLIP "L" MULLBAR CLIP (F-1522-XXX) (F-1767XXX)FLANGE NEW F-1522-013 F-1767-001 QmtzffEd RETRO F-1522-006 F-1767-001 1900 SW 44TH AVE. NEW F-1522-013 F-1767-004(L&R) OCALA, FLORIDA 34474 I FIN WWWCWS.CC RETRO F-1522-013 F-1767-004(L&R) NEW NOT RECOMMENDED F-1767-001 BOX 3" PVC RETRO F-1522-006 I F-1767-001 r-23/4- \J 21/4• _-1 (2 314•) 7/16' THRU(TYP)- 1@' MULL BAR NON -IMPACT a ? azo 0 w zpz cc~zW U. I-w§z�3'2x z O zx2¢wwop pm pp a �aF-ta [n ? re �?< ow -mop �pFFFpZ 2 7/16• F 0w��}��i0� to W p 0- 1 Z a FF& WSW' a l _D__ 1/4• THRU (TYP) •L• ANGLE 3' STANDARD MULL CLIP - F-1767-001 7 9/26/2017 LUCAS A. TURNER, P.E. FL PE # 68201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 SHEET DESCRIPTION: EXTRUSIONS DRAWN BY: DATE: RS 04/13/09 DWG#: REV_ CWS-430 C SCALE: SHEET 1:2 5 OF 10 � U SEAL BEHIND FLANGE SEAL BEHIND FLANGE O PRIOR TO ATTACHING = APPLY SEALANT ALONG FULL , PRIOR TO ATTACHING TO MULLION LENGTH OF WINDOW FRAME TO MULLION Q 2I —O2 GROOVE PRIOR TO ATTACHING 2 9 1 g !I 1 COVER 1 I 11 11 11 I 11 FIN MUST BE REMOVED p O WHERE WINDOWS CONNECT TO MULL � i I I I HORIZONTAL MULL BAR SECTION �1 HORIZONTAL MULL BAR SECTION 1 %AIVERTICAL HORIZONTAL MULL BAR SECTION 6 FLANGE FRAME WINDOW I 6 FIN FRAME WINDOW I 6 BOX FRAME WINDOW i — — — — — — — — — — — — — — — — — — -- — — J — — — — — — — — — — — — — -- — — — — — — — — — — — — APPLY SEALANT ALONG FULL 11 1 2 1 11 1 2 LENGTH OF MULLBAR GROOVE PRIOR TO ATTACHING DRIP i ADAPTOR FIN MUST BE REMOVED WHERE WINDOWS 1 CONNECT TO MULL I g 0 0 o i DETAIL A I � I SEAL BEHIND FLANGE I SEAL BEHIND FLANGE 10 (SEE DETAIL B) I PRIOR TO ATTACHING 10 (SEE DETAIL B) PRIOR TO ATTACHING TO MULLION - I APPLY SEALANT ALONG FULL TO MULLION i I LENGTH OF MULLBAR GROOVE PRIOR TO ATTACHING FLANGE i �1VERTICAL MULL BAR SECTION I �ZVERTICAL MULL BAR SECTION I ADAPTOR 1 6 FLANGE FRAME WINDOW I s FIN FRAME WINDOW I" I ' L i r i I 10 I DETAIL B I I 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CWS.CC 3" PVC MULL BAR NON -IMPACT Q Z ¢Z� P OWO WHO' O W ZOZ M==IW_- O amp ti F-W ZI-3:;E_ -Z Z2m¢wWOO O ol-0cn�Oarrnn- rn ? Z 00--.3 -j0- ¢ H?LLg0OWZ 1�owF=I=-O- ¢ I- ZC6 I! OOww wvi0m �" rn W O J (A a I- a:aW=� �a� a a � z� 9/26/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 SECTION VIEWS MULLS RS 1 04/13/09 CWS-430 C ALE' SHEET 1:2 6 OF 10 TOP VIEW FIN FRAME -- - -- 5'M000BAR_(H=1760)- -- (SEE SEPARATE APPROVAL FOR APPROPRIATE DP CHARTS) SEE NOTE 1 I YI I 111 U SEE NOTES 1& 2 (2 EAJCUP) 5' HORIZ. TO 3' VERT. MULLBAR SECTION 7 FLANGE FRAME WINDOW MULLBAR (H-1759) EE SEPARATE APPROVAL FOR 'PROPRIATE DP CHARTS) ,TE 1 =S1&2 (2 EA./CLIP) C 4' HORIZ. TO 3' VERT. MULLBAR SECTION (FLACTGE FRAMF WINDOW SECTION VIEW A -A =E NOTE 1 E NOTES 1 & 2 -A.ICLIP) �3' HORIZ TO 3' VERT. MULLBAR SECTION �FLANG FRAME WINDOW NOTES: 1. SLIDE CLIP INTO LOCATION AND SECURE WITH REM 19 (OTY 2), AS SHOWN ABOVE. 2. PRE -DRILLED HOLES (THRU HN CLIP 1897). BY THE INSTALLER, MAY BE LOCATED AS NEEDED WHILE MAINTAINING A MINIMUM CLIP EDGE DISTANCE OF 9132' AND A MINIMUM CENTER TO CENTER SPACING OF 112'. 3. THE ABOVE SECTIONS APPLY TO ALL MULLBAR-TO-MULLBAR CONNECTIONS, REGARDLESS OF ORIENTATION (i.e., HORIZONTAL OR VERTICAL). THE FULL LENGTH MULL MUST BE THE SAME DEPTH, OR GREATER, THAN THE INTERSECTING MULL. 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 3" PVC. MULL BAR NON -IMPACT I— z ¢z� ow0 avow Z IIIzoz o WJo oft? ¢v1—>oo:�m It Z I-W�ZI-��x zxm<wwoo 0 0 01-0 ¢xFW 0cn7 -z Q-P U)E Z � p—ZjU� zowzDo Q Y ' ¢,Q�}�U�,IOxOZ Ia- O0QF>���� Zcow�O_jaiF d 0 co CC 0. x~a Q�wul 9/26/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 IEET DESCRIPTION: SECTION VIEWS MULL INTERSECTIONS LAWN BY: DATE: RS 04/13/09 VG #: REV_ CWS-430 C :ALE: SHEET 12 7 OF 10 0 TRANSOM OVER TWIN VERTICAL MULLION " OPENING SIZE TRANSOM OVER TRIPLE VERTICAL MULLION 7 L 3 I II +I nPFNIN(: C17F L TWIN VERTICAL MULLION i LI F-- OPENINGSIZE— F C� J 1 TRIPLE VERTICAL MULLION OPFNIKlr C17P HORIZONTAL MULLION w N z ISINGLE1 Z TWIN w OR o ITRIPLE1 UNITS BELOW I-- MULL LENG NOTES: 1. AT MULLION LOCATION, ATTACH WINDOW UNIT(S) TO MULLBAR THRU FRAME AS SPECIFIED IN WINDOW UNIT APPROVAL DOCUMENTS. IF ALUMINUM ATTACHMENT IS NOT SPECIFIED IN THE WINDOW UNIT APPROVAL DOCUMENTS, FOLLOW THE ANCHOR SPACING AS INDICATED IN THE WINDOW APPROVAL FOR ATTACHMENT TO WOOD SUBSTRATE, USING A HEX WASHER HEAD TEK SCREW OF THE SAME SIZE (#10 OR #12) AS THE WOOD SCREW INDICATED IN THE WINDOW APPROVAL. TEK.SCREWS SHALL BE LONG ENOUGH TO ENSURE THREE (3) THREADS OF PENETRATION BEYOND THE INSIDE WALL OF MULLBAR. 2. MULL CLIP INSTALLATION ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 9. 3. ALL MULL CLIP INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTION. 4. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM SPECIFIED IN TABLE 1, SHEET 9. 5. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE -1X BUCKS ARE OPTIONAL. 6. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED AS INDICATED BY THE PRE -DRILLED HOLES AS SHOWN IN THE CLIP LAYOUTS ON SHEETS 4-5. 7. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE, SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET, SHEET 9. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. 8. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: FMA/AAMA 100(FIN WINDOWS), FMA/AAMA 200(FLANGE WINDOWS), FMANVDMA 250(BOX WINDOWS), FMA/AAMANVDMA 300(EXTERIOR DOORS) Qu�mo 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CWS.CC 3" PVC MULL BAR NON -IMPACT Q F- ? Q Z 3. ❑WO QW00 Z WJo u0 0 zz ZwZ>-O��m W Z F--W�ZF- :2H! zmm<wwOO 0 Orn�zG-Pcoa. Z Z0 Z) Z7Uu] Q<�O}}FFFO_ F- DOF>- 3:0Ui 2 LL Z CO w 0 _j A F- a o _~� W a. �Wul - EL F_-°=—X-- a-- /,_ 9/26/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 CONFIGURATIONS AND ANCHORAGE NOTES RS 1 04/13/09 CWS-430 C .ALE: SHEET 1:1 8 OF 10 SEALANTALONG OUTSIDE EXPOSED EDGE BY INSTALLER PERIMETER SEALANT — BY INSTALLER INSIDE AND OUT SUBSTRATE BY -OTHERS SEE TABLE 1 MIN. EDGE DIST. SEE TABLE 1 WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 www.cws.cc 3" PVC MULL BAR NON -IMPACT RETRO FIT "L' ANGLE MULL BAR CLIP MULL BAR CLIP TWO REQ'D PER EACH END OF MULL Q Z ?�0wo Q Z Inwon - MULL BAR .. _ MULL BAR Z W _j 0 Q F- W u u o QcoZ>Om5co li FW2'ZI-�i22 INSTALLATION ANCHOR INSTALLATION AN U SEE TABLE 1 �� SEE TABLEA 0 Z- n- Z F j U) ADD STRUCTURAL ELEMENTS = -1- _ = ADD STRUCTURAL ELEMENTS Z 0 O U U 7 U ' AS REQ'D TO MAKE LEVEL FOR SEALANT ALONG - - _ - - _ AS REQ'D TO MAKE LEVEL FOR Q tL O O W Z MULL BAR OUTSIDE EXPOSED — MULL BAR ¢ O W F H Z - EDGE BY INSTALLER 2 U Uj PERIMETER SEALANT - W O n n p W W MIN. EMBEDMENT BY INSTALLER MIN. EMBEDMENT w Z d O ~ SEE TABLE 1 INSIDE AND OUT SEE TABLE 1 - - p W F 0 W = SEE TABLE IBY OTHERS %Dl' VERTICAL SECTION 9 TYPICAL FLANGE (RETRO FIT) ANCHORAGE HEAD AND JAMBS SIMILAR FOR FLANGE INSTALLATION TABLE 1: APPROVED MULL CLIP INSTALLATION FASTENERS SUBSTRATE TYPE ANCHOR TYPE MIN. EMBEDMENT MIN. EDGE DIST. CONCRETE (2.0 KSI MIN.) 3/16" ITW TAPCON 1" 3" CONCRETE (2.85 KSI MIN.) 3116" ELCO ULTRACON 1-3/4" 1" HOLLOW or GROUT -FILLED CMU (ASTM C-90) 1/4" ELCO ULTRACON 1-1/4" 2-1/2" 2X MIN. SOUTHERN PINE (G=0.55) 3/16" ITW TAPCON 1-3/B" 7/8" OR ELCO ULTRACON 2XMIN. SOUTHERN PINE (G=0.55) #10 WOOD SCREW 1-3/8" 7/8" 16 GAUGE (0.060") MIN. STEEL STUD #10-16 HILTI KWIK-FLEXOR ITW FULL THREAD (33 KSI YIELD MIN) TEKS SELF -DRILLING SCREW THRU 0.060" 7/16' 1/8" ALUM. (6063-T5 MIN.) OR #10 GRADE 5 SELF -TAPPING / FULL THREAD 1/8" STEEL (33 KSI MIN.) DRILLING SCREW THRU 0.125" 7/16" "-1 MIN. EDGE DIST. SEE TABLE 1 rE1 VERTICAL SECTION 9 TYPICAL FLANGE ("L" ANGLE) ANCHORAGE HEAD AND JAMBS SIMILAR FOR FLANGE INSTALLATION NOTES: 1. BOX FRAME MULL INSTALLATION SIMILAR TO FLANGE FRAME. 2. SILL STOOL MUST BE FLUSH AGAINST INSIDE OF MULLED WINDOWS AFTER INSTALLATION. 3. RECESS RETRO MULLION CLIP 3/8" MAX. FOR CLEARANCE OF WINDOW UNIT AS NEEDED. 4. FOUR (4) ANCHORS REQUIRED PER "T- MULL CLIP, SEE SHEET 2. TWO (2) or THREE (3) ANCHORS REQUIRED PER "L" MULL' CLIP, SEE SHEETS 2-3. 5. SEAT MULLION TIGHT TO MULL CLIP. 6. FOR ANCHORAGE DETAILS FOR THE WINDOW, REFER TO THE WINDOW SPECIFIC INSTALLATION DETAILS. r.-.-_ 9/26/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 HEET DESCRIPTION: INSTALLATION DETAILS FLANGE RAWN BY: DATE: RS 04/13/09 WG#: REV.: CWS-430 C GALE` SHEET 1:2 9 OF 10 RETRO FIT MULL BAR CLIP MULL BAR — L ` - - INSTALLATION ANCHOR d I SEE TABLE 1. SHT 9 SEALANT ALONGE - SEALANTALONGE - OUTSIDE EXPOSED OUTSIDE EXPOSED EDGE BY INSTALLER EDGE BY INSTALLER EXTERIOR FINISH-- _ MIN _EMBEDMENT - _ EXTERIOR FINISH BY OTHERS ," ot.. _ ___ _ _ SEE TABLE 1, SHT 9 BY OTHERS PERIMETER SEALANT PERIMETER SEALANT - BY NSTALLER BYINSTALLER INSIDE AND OUT INSIDE AND OUT SUBSTRATE BY OTHERS SUBSTRATE BY OTHERS SEE TABLE 1, SHT 9 ^ SEE TABLE 1, SHT 9 MIN. EDGE DIST. SEE TABLE 1, SHT 9 FF� VERTICAL SECTION 10. TYPICAL FIN (RETRO FIT) ANCHORAGE HEAD AND JAMBS SIMILAR FOR FIN INSTALLATION 'L" ANGLE CLIP- E= PER EACH END OF MULL MULL BAR it ?: fLO INSTALLATION ANCHOR I� SEE TABLE 1, SHT 9 EDGE DIST. VERTICAL SECTION SEE TABLE 1, SHT 9 10 TYPICAL FIN (-L- ANGLE) ANCHORAGE HEAD AND JAMBS SIMILAR FOR FIN INSTALLATION V- IuYW/o I]'I-I� WINDOW SYSTEMS I\ �/I 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 3" PVC MULL BAR NON -IMPACT a P z �: QZ�: owo wwoo Zoz wMw O_ LL Z 1-w ZF-�ig2 Zmm<wwpp o O OI-o a=Fw Um,z0-I-mD- Q OZpw D - >_ O LL flowCmoZ I~L1 W(AW wa p-iWF- co p wl-o wO w>_ w In - --- -° - ~ a- a 9/262017 LUCAS A. TURNER, P.E. NOTES: FL PE # 58201 1239 JABARA AVE. 1. SILL STOOL MUST BE FLUSH AGAINST INSIDE OF MULLED WINDOWS NORTH PORT, FL 34288 AFTER INSTALLATION. PH.941-380-1574 2. RECESS RETRO MULLION CLIP 3/8' MAX. FOR CLEARANCE OF WINDOW SHEET DESCRIPTION: UNIT AS NEEDED. INSTALLATION DETAILS FIN 3. FOUR (4) ANCHORS REQUIRED PER T MULL CLIP, SEE SHEET 2. TWO (2) or THREE (3) ANCHORS REQUIRED PER "L" MULL CLIP, SEE SHEETS 2-3. DRAWN BY: DATE: RS 04/13/09 4. SEAT MULLION TIGHT -TO MULL CLIP. DWGp: REV.: 5. FOR ANCHORAGE DETAILS FOR THE WINDOW, REFER TO THE WINDOW CWS-430 C SPECIFIC INSTALLATION DETAILS. SCALE: SHEET 1.2 100F 10