Loading...
HomeMy WebLinkAboutTRUSS DESIGN DRAWING & DETAILSSimpson Strong -Tie ®Company, Inc: • TRUSS DESIGN DR WINGS & DETAILS 5956 W. Las Positas Blvd. Pleasanton, CA 94588 ® (800) 999-5099 00 6 www.strongtie.com R M Building Components 00280- Hancock Residence -Tree Top Trail RECEIVED 5/23/2018 10:23 AM W BY E: D AUG 13 2018 66489 t Lucie colun ST. Lucle County, Permitting Notes: 1. The truss design drawings referenced below have been prepared ased on design criteria and requirements set forth in the Construction Documents, as communicated by the Truss Manufac rer. 2. The engineer's signature on these drawings indicates professional engineering responsibility solely for the individual components to be able to resist the design loads indicated, utilizing all the desi n parameter and materials indicated or referenced on each individual design. 3. It is the Building Designer's responsibility to review the truss desig I drawings to insure compatibility with the Building design, Refer to all notes on the individual truss design drawings. 26 Truss Design Drawing(s): 1-A1: SID 258531 8-A4: SID 258538 15'Wk SID 258545 22-J3: SID 258552 2-A1A: SID 258532 9-A4A: SID 258539 1 -Bi: SID 258546 23-J313: SID 258553 3-A1 B: SID 258533 10-A5: SID 258540 1 -J17: SID 258547 24-Vl: SID 258554 4-A2: SID 258534 11-A5A: SID 258541 1 -J13: SID 258548 2542: SID 258555 5'A2A: SID 258535 12-A6: SID 258542 1 -J25: SID 258549 26-V3: SID 258556 6-A3: SID 258536 13-A6A: SID 258543 2 -J23: SID 258550 7-A3A: SID 258537 14-A7: SID 258544 2 -J21: SID 258551 r ��COVY Component SolutionsTM I portant Information & General Notes nbols and Nomenclature G Plate size; the first digit is the late width er to the slots 1' 5X7 9• P (P P• ) and the second digit is the plate length (parallel to the slots). 5X7-18 IA -18, -1855 or -1856 following the plate size indicates different 18 ga plate types These symbols following the plate size indicate the direction of the plate length (and tooth slots) for square and nearly square plates. 10-3-14 Dimensions are shown in feet -inches -sixteenths (for this example, the dimension is 10'-3 14/16"). Joints are numbered left to right, first along the top chord and then along the bottom chord. Mid -panel splice joint numbers are not shown on the drawing. Members are 2 identified using their end joint numbers (e.g., TC 2-3). When this symbol is shown, lateral restraint is required on the member near the location(s) indicated on the graphic and in the Bracing Data Summary. See Note 3 under Handling, Installing, Restraint & Bracing for more information. Bearing supports (wall, beam or other), on which the truss must completely bear. Bearing material is checked for perpendicular -to -grain resistance only. The Building Designer is responsible for all other bearing design considerations. n / Truss -to -Truss or Truss -to -Structural Element connections, which require a hanger or other structural connection (e.g., toe -nail) that has adequate capacity to resist the max. reactions and uplifts shown in the Reaction Summary. Design of the Structural Element and the connection of the Truss to the Structural Element is by others. Note: These symbols are for graphical interpretation only; they are not intended to give any indication of the geometry requirements of the actual item that is represented. Materials and Fabrication Design assumes truss is manufactured in accordance with the TDD and the quality criteria in ANSI/TPI 1 Chapter 3, unless more restrictive criteria are part of the contract specifications. Unless specifically stated, lumber shall not exceed 19% moisture content at time of fabrication or in service. Design is not applicable for use with fire retardant, preservative treated or green lumber unless specifically stated on the TDD. Plate type, size, orientation and location indicated are minimum plating requirements. Plates shall be embedded on both faces of the truss at each joint. Truss plates shall be centered on the joint unless otherwise specified on the joint details. Referenced Standards ANSI/TPI 1: National Design Standard for Metal Plate Connected Wood Truss Construction , a Truss Plate Institute publication (www.tpinst.org). BCSI: Guide to Good Practice for Handling, Installing, Restraining & Bracing Metal Plate Connected Wood Trusses, a joint publication of the Truss Plate Institute (www.tpinst.org ) and the Structural Building Components Association (www.sbcindustry.com ). feral Notes ich Truss Design Drawing (TDD) provided with this sheet has been )pared in conformance with ANSI/TPI 1. Refer to ANSI/TPI 1 Chapter 2 for finitions of all capitalized terms and for the responsibilities of all parties folved, which include but are not limited to the responsibilities listed on this eet. 2. TDDs should not be assumed to be to scale. 3. The Contractor and Building Designer shall review and approve the ITruss Submittal Package. 4. The suitability and use of the component depicted on the TDD for any articular building design is the responsibility of the Building Designer. 5. he Building Designer is responsible for the anchorage of the truss at all earing locations as required to resist uplift, gravity and lateral loads, and for II Truss -to -Structural Element connections except Truss -to -Truss 6. Fhe Building Designer shall ensure that the supporting structure can ccommodate the vertical and/or horizontal truss deflections. 7. Unless specifically stated otherwise, each Design assumes trusses will be adequately protected from the environment, including not being used in locations where the sustained temperature is greater than 150°F. 8. Trusses are designed to carry loads within their plane. Any out -of -plane loads must be resisted by the Permanent Building Stability Bracing. 9. Design dead loads must account for all materials, including self -weight. The TDD notes will indicate the min. pitch above which the dead loads are automatically increa sed for pitch effects. 71 . Trusses installed with roof slopes less than 0.25/12 may experience (but are not designed for) ponding. The Building Designer must ensure that adequate drainage is provided to prevent ponding. - ling, Installing, Restraint & Bracing 1 The Contractor is responsible for the proper handling, erection, restraint and bracing of the Trusses. In lieu of job -specific details, refer to BCSI. 2 ANSI/TPI 1 stipulates that for trusses spanning 60' or greater, the Owner shall contract with any Registered Design Professional for the design and inspection of the temporary and permanent truss restraint and bracing. Simpson Strong -Tie is not responsible for providing these services. 3 Trusses require permanent lateral restraint of chords and certain web members (when indicated) at the locations or intervals indicated on the TDD. This shall be accomplished in accordance with: standard industry lateral restraint/bracing details in BCSI-133 or BCSI-137, supplemental bracing details referenced on the TDD, or as specified in a project -specific truss permanent bracing plan provided by the Building Designer. 4. Additional building stability permanent bracing shall be installed as specified in the Construction Documents. Special end wall bracing design considerations may be required if a flat gable end frame is used with adjacent trusses that have sloped bottom chords (see BCSI-133). Do not cut, drill, trim, or otherwise alter truss members or plates without prior written approval of an engineer, unless specifically noted on the TDD. Piggyback assemblies shall be braced as per BCSI-133 unless otherwise specified in the Construction Documents. DSB-89 Recommended Design Specification for Temporary Bracing of Metal Plate Connected Wood Trusses, a Truss Plate Institute publication (www.tpinst.org). NDS: National Design Specification for Wood Construction published by American Forest & Paper Association and American Wood Council: ESR-2762 Simpson Strong -Tie® AS Truss Plates are covered under ESR-2762 published by the International Code Council Evaluation Service (www.icc-es.org ). TD-GEN-0003A 6/2015 Project Name: 00280 - Hancock Residence - Tree Top Trail Qty: 4 Truss: Al Customer: Gillespie Builders SID: 0000258531 TID: 66489 Date: 05 / 23 / 18 Truss Mfr. Contact: Rick Mills Page: 1 of 1 2-0-0 6-6-8 5-10-12 5-10-12 5-10-12 5-10-12 6-6-8 66 6-8 12-5-4 18-4-0 24-2-12 30-1-8 36-8-0 1 2 3 4 5 6 7 4x6 5/12 Sx7 SO -5/12 r 2x3%% n 2x3a rn coo 4-1 3x8 3x8 4-1 X 8„ 3x4= 3x6 3x4= 3x4= 3x6 3x4. 8„ 7-4-14 6-9-2 8-4- 6-9-2 7-4-14 7-4-14 14-2-0 22-6 0 29-3-2 36-8-0 1 8 9 10 11 12 13 7 36-8 0 Plates -- Simpson Strong -Tie 20 ga (AS20) or 18 ga (AS18HS, AS18S5, or AS18S6) indicated by '-18' Code/Design: FBC-2017/TPI-2014 -----------Snow Load Specs ----------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-10 Ground Snow(Pg) = N/A ASCE7-10 Wind Speed(V) = 170 mph 10 ps£ Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 0.0 ft B = 0.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: HybridMW OH Soffit Load: 2.0 PSF Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #1--------------Reaction Summary(LbM --------------- TrussSpan Limit Actual(in) Location 2x4 SP (ALSC6-2013) #2 3-4 Jnt--X-Loc- React -Up- --Width- - eqd -Mat PSI Vert LL L/360 L/999(-0.29) 10-11 4-5 1 03-14 1594 842 08-00 0 -08 SPF 425 Vert CR L/240 L/766(-0.55) 10-11 BC 2x4 SP (ALSC6-2013) #1 7 36-04-02 1594 835 08-00 0 -08 SPF 425 Webs 2x4 SP (ALSC6-2013) #2 Max Horiz = -317 / +300 at Join 1 Horz LL 0.75in ( 0.11) @Jt 1 Horz CR 1.25in ( 0.13) @Jt 1 Member Forces Summary Loads Summary ..Mem... Ten Comp .CSI. This truss has been designed for th effects of an unbalanced top chord TC OH- 1 51 0 0.41 live load occurring at [180400] usi g a 1.00 Full and 0.00 Reduced load 1- 2 2453 2950 0.90 factor. Vert CR and Horz CR are the vertical and 2- 3 2508 2834 0.70 horizontal deflections due to live load 3- 4 2197 2292 0.94 See Loadcase Report for loading cc inations and additional details. plus the creep component of deflection 4- 5 2182 2292 0.93 Dead Loads may be slope adjusted: > 12.0/12 due to dead load, computed as Defl LL + 5- 6 2494 2834 0.70 (Kcr - 1) x Defl_DL in accordance with 6- 7 2438 2950 0.89 ANSI/TPI 1- 7-OH 51 0 0.41 Notes BC 1- 8 2647 1967 0.78 Plates designed for Cq at 0.80 and otational Tolerance of 10.0 7-13 2647 1969 0.78 degrees Bracing Data Summary 8- 9 2227 1539 0.44 Plates located at TC pitch breaks m et the prescriptive minimum size ------------Bracing Data ------------ 9-10 2227 1539 0.71 requirement to transfer unblocked d'aphragm loads across those joints. Chords; continuous except where shown 10-11 1667 962 0.69 Web Bracing -- None 11-12 2227 1539 0.71 12r- 13 2227 1539 0.44 Plate offsets Iv Web 2- 8 503 285 0.34 3- 8 0.28 (None unless, indicated below) 719 561 3-10 797 0.87 Jntl(00-02,0), Jnt3(-00-06,00-15), 9-10 797 706 0.87 706 Jnt5(00-06,00-15), Jnt7(-00-02,0) 4-11 797 707 0.87 5--11 720 561 0.28 5-13 503 415 0.34 6-13 449 285 0.08 L. G(4N ///. %���: _\GEN _ * No. 76864 Q� •. ST E `� / / / 15/23/2018 COA #30003 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is Ijased on design criteria and requirements supplied by th Component Solutions Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building gesigner. A seal on this drawing indicates acceptance of Truss Studio V professional engineering responsibility solely for the truss component design shown. See the cover page and thf "Important Infonmabon & General Notes" page for 2018.1. 0.87 additional information. All connectorplates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge r Het desk: I-866-252-8606 unless the specified plate size is followed by a "-18"which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. P ® CSHelp@strongtie.com i Project Name: 00280- Hancock Residence - Tree Top Trail I Qty: 2 Truss: A1A Customer: Gillespie Builders SID: 0000258532 TID: 66489 Date: 05 / 24 / 18 Truss Mfr. Contact: Rick Mills Page: 1 of 1 2-0-0 7-5-14 6-5-6 2-2-6 2-2-6 2-2-6 2-2-6 6-5-6 7-5-14 7-5-14 13-11-4 4 6-1-1018-4-g620-6-672-8-81 29-2-2 36-8-0 1 2 3 9 10 11 lObO# Ix4=10�0# W, 2x3/ 3x10 3x6 a 5/12 3x6 3x10 -5/12 18 19 3X4,- 3x6 3x6 3x4o r. r ' - 5-2 11 a ' rb 4-1 4x6 8 6-0 4x8 4-1 X 8„ 2x4 5x14-18 3x6 3x6 5x14-18 2x4 b b 54# 54# 7-5-14 6-5-6 8 9-8 6-5-6 7-5-14 7-5-14 13-11-4 22 8-12 29-2-2 36-8-0 1 12 13 14 15 16 17 11 Plates -- Simpson Strong -Tie 20 ga (AS20) or 18 ga (AS18HS, AS18S5, or AS18S6)lindicated by '-18' Code/Design: FBC-2017/TPI-2014 -----------Snow Load Specs ----------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSFLive Dead Dur Factors ASCE7-10 Ground Snow(Pg) = N/A ASCE7-10 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 0.0 ft B = 0.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 0.c. Plies: 1 Unobstructed Slippery Roof: No Partially Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: No Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: HybridMW OH Soffit Load: 2.0 PSF Material Summary TC 2x4 SP (ALSC6-2013) 2x4 SP (ALSC6-2013) 6-8 BC 2x6 SP (ALSC6-2013) 2x6 SP (ALSC6-2013) Wgibs 2x4 SP (ALSC6-2013) Member Forces Summary ..Mem... Ten Comp .CSI. TC OH- 1 53 0 0.48 s 1- 2 2111 3818 0.81 2- 3 1735 3420 0.76 3- 4 1740 3320 0.82 4- 5 472 1063 0.60 5- 6 488 963 0.17 6- 7 483 977 0.17 7- 8 472 1063 0.26 8- 9 467 1081 0.39 9-10 1728 3423 0.83 10-11 2278 3972 0.90 BC 1-12 3468 1772 0.76 11-17 3617 1950 0.90 1Z-13 3468 1772 0.85 13-14 3468 1772 0.93 14-15 3097 1181 0.95 15-16 3617 1950 0.87 16-17 3617 1950 0.87 Web 2-12 194 90 0.04 2' 14 655 744 0.59 4-14 726 178 0.20 4-18 1356 1778 0.25 5-18 107 200 0.02 6-18 332 110 0.07 6-19 349 125 0.08 7-19 114 218 0.02 9-15 736 195 0.20 9-19 1336 1765 0.24 10-15 852 904 0.72 10-17 265 105 0.06 18-19 1448 1987 0.26 Reaction Summary #1--------------Reaction Summary(Lbs)- --- #2 3-6 Jnt--X-Loc- React -Up- --Width- -R qd 1 04-00 1895 690 08-00 03 00 #2 11 36-06-08 1752 572 03-00 H R 41 13-16 Max Horiz = -287 / +328 at Joint 1 #2 Deflection Summary --------- TrussSpran Limit Actual(in) Location -Mat PSI Vert LL L/360 L/999(-0.34) 14-15 SPF 425 Vert CR L/240 L/672(-0.64) 14-15 SPF 565 Horz LL 0.75in ( 0.06) @Jtll Horz CR 1.25in ( 0.13) @Jtll Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at (180400] usin a 1.00 Full and 0.00 Reduced load factor. Attic space centered at 18-04-00 is oaded with 30.00 PSF Live 6 10.00 PSF Dead Floor, 5.00 PSF Dead Wall, 5.00 PSF Dead Ceiling loads, and meets deflection criteria L/360. See Loadcase Report for loading com Dead Loads may be slope adjusted: > Concentrated Loads - Based on Live Domain Load Uplift Location D User loads: TC 100 0 16-10-00 V TC 100 0 19-10-00 V Notes Plates designed for Cq at 0.80 and degrees Plates located at TC pitch breaks requirement to transfer unblocked tions and additional details. 0/12 Description User -Defined @ 90 Deg User -Defined @ 90 Deg tional Tolerance of 10.0 the prescriptive minimum size ragm loads across those joints. Vert CR and Horz CR are the vertical and horizontal deflections due to live load plus the creep component of deflection due to dead load, computed as Defl LL + (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. Bracing Data Summary ------------Bracing Data ------------ Chords; continuous except where shown Web Bracing -- None Brace Tie -Beam - rigid ceiling or CLR at location(s) shown (applied either edge) Plate offsets (X, Y): (None unless indicated below) ,Tntl(01-01,00-09), Jntll(-01-00,00-07), ,Tnt14(0,-01-04), Jntl5(0,-01-04) i i * No. 76864 AL tE COA #30003 5/23/2018 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by th• ® Component Solutions Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building designer. Asea] on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and th4 "Important Information & General Notes" page for Truss Studio V additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accor ante with ESR-2762. All connector plates are 20 gauge 2018.1.0. 87 ' unless the specified plate size is followed by a "-18° which indicates an 18 gauge plate, or °S# 18", which indigt s a high tension 18 gauge plate. Helpdesk: 1-866-252-8606CSHelp@strongtie. com Project Name: 00280- Hancock Residence - Tree Top Trail Qty: 9 Truss: A1B Customer: Gillespie Builders SID: 0000258533 TID: 66489 Date: 05 / 24 / 18 Truss Mfr. Contact: Rick Mills Page: 1 of 1 2-0-0 5-8-9 5-0-11 5-0-11 2-6-0 6-4-0 6-8-0 5-4-0 2-0-0 5-8-9 10-9-5 15-10-0 18-4-0 24-8-0 31-4-0 36-8-0 1 2 3 4 5 6 7 8 9 10 5x7 2x3i 5/12 3x6 3x6 -5/12 3x6 3x4% N i W. n 4x6 O1 ' 7x8= 3x6 3x8 3x10-18 3x4= 4-1 3x4= �^ 4x12 4-1 X 2.5/12 -2.5/12 X 4x12 8„ 31-4-0 8„ 8-2-15 7-7-1 8-10-0 6-4-0 5-8-0 8-2-15 15-10-0 24-8-0 31-0-0 36-8-0 1 11 12 13 14 15 10 36-8-0 Al - Plates -- Simpson Strong -Tie 20 ga ,(AS20) or 18 ga (AS18HS, AS18S5, or AS18S6) �ndicated by •-181 Code/Design: FBC-2017/TPI-2014 -----------Snow Load Specs ----------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead our Factors ASCE7-10 Ground Snow(Pg) = N/A ASCE7-10 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 I= 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 0.0 ft B = 0.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Partially Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) - 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: HybridMW OH Soffit Load: 2.0 PSF Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2 --------------Reaction Summary(Lbs)- -------------- TrussSpah Limit Actual(in) Location 2x4 SP (ALSC6-2013) #1 1-4 Jnt--X-Loc- React -Up- --Width- -R qd -Mat PSI Vert LL L/360 L/999(-0.27) 13-14 BC 2x4 SP (ALSC6-2013) #1 1 04-00 1271 681 08-00 02 00 SPF 425 Vert CR L/240 L/538(-0.68) 13-14 2x4 SP (ALSC6-2013) #2 13-15 15 31-02-12 2275 1130 08-00 03 09 SPF 425 15-10 10 36-04-02 135 572 08-00 00-03 SPF 425 Horz LL 0.75in ( 0.16) @Jt10 WEbs 2x4 SP (ALSC6-2013) #2 Max Horiz = _317 / +304 at Joint 1 Horz CR 1.25in ( 0.31) @Jt10 2x6 SP (ALSC6-2013) #2 15-9 Wedge 2x4 SP (ALSC6-2013) #2 Loads Summary Member Forces Summary This truss has been designed for the live load effects of an unbalanced top chord Vert Horz CR are the vertical and ...Mem... Ten Comp .CSI. occurring at [1804001 usin factor. a 1.00 Full and 0.00 Reduced load horizCRontand al deflections due to live load TC OH- 1 49 0 0.41 plus the creep component of deflection 1- 2 2962 3789 0.77 See Loadcase Report for loading comb.nations and additional details. due to dead load, computed as Defl LL + 2- 3 2650 3524 0.65 Dead Loads may be slope adjusted: > 2.0/12 (Kcr - 1) x Defl_DL in accordance with 3- 4 1828 2466 0.56 ANSI/TPI 1. 4- 5 1840 2420 0.57 5- 6 1952 2392 0.65 Notes 6- 7 1189 1166 0.66 Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 Bracing Data Summary 7- 8 1168 1183 0.90 degrees ------------Bracing Data ------------ 8- 9 912 1170 0.86 9-10 1732 1380 0.94 Plates located at TC pitch breaks me t the prescriptive minimum size Chords; continuous except where shown 10-OH 51 0 0.56 requirement to transfer unblocked di Continuous Lateral Restraint (CLR) rows loads across those joints. require diagonal bracing per ------- Web Bracing -- CLR----------- Single: 6-14 14- 9 BC L-11 3515 2468 0.75 D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Continuous Restraint Bracing Req'd 10-15 1487 1539 0.32 See BCSI-B3 3.0 11-12 3084 2033 0.58 12-13 3108 2030 0.75 Plate offsets (X, Y): 13-14 1428 509 0.92 (None unless indicated below) 14-15 1527 1581 0.57 2 Jntl(00-05,00-06), Jnt6(0,-00-03), Web 11 415 231 0.07 3-11 421 63 0.09 Jnt10 (-01-07,00-09) T tl3(0,-00-01), Jntl5 (0,-00 i I 17 3-13 959 833 0.42 - \1� 1 5-13 264 143 0.096-13 11 621 \\\ �! L• G / /// /// 6-14348 614 2 \\ ��\ • •�V�/� -14 0.1 9-14 2582 1898 0.58 \\ `�; ••� i 9-15 1624 1831 0.20 * No. 76864 Q ST E ONAL / / I I I t t5123/2018 COA #30003 NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by th Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building DI signer. A seal on this drawing indicates acceptance of ® Component Solutions professional engineering responsibility sole) for the truss p g g p y component design shown. See the cover page and the'Im Important p g p g Information & General Notes" page... for p p g truss Studio v additional information.All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge 2018.1.0.87 unless the specified plate size is followed by a •-18" which indicates an 18 gauge plate, or-S# 18", which indicates a high tension 18 gauge plate. � � Helpdesk: 1-866-252-8606 ® CSHelp@strongtie.com Project Name: 00280- Hancock Residence - Tree Top Trail I Qty 1 Truss: A2 Customer: Gillespie Builders SID: 0000258534 TID: 66489 Date: 05 / 24 / 18 Truss Mfr. Contact: Rick Mills Page: 1 of 1 2-0-0, 5-8-9 5-0-11 5-0-11 1-0- 2-11-0! 5-7-4 5-i1-4 5-4-0 2-0-0, Z 5-8-9 10-9-5 15-10-0 1 -1o¢s 19 9 88 25-4-12 31-4-0 36-8-0 r 1 2 3 4 5 6 7 8 9 10 11 4x6 4x4= 2x3i • 3x6 5/12 3x6 -5/12 3x4= 3x4. 2x3; 4x6 7x8= 4x12 SxS= 3x8 3x4= 4-1 3x4= 4-1 2.5/12 3x8 -2.5/12 Z 4x12 8" 31-4-0 8" 8-2-15 7-7-1 3-11-8 5-7-4 5-7-4 5-8-0 8-2-15 15-10-0 19-9-8 25-4-12 31-0-0 36-8-0 1 12 13 14 15 16 17 11 36-8- Plates -- Simpson Strong -Tie 20 ga (AS20) or 18 ga (AS18HS, AS1895, or AS18S6) ndicated by '-18, Code/Design: FBC-2017/TPI-2014 -----------Snow Load Specs ----------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-10 Ground Snow(Pg) = N/A ASCE7-10 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 0.0 ft B = 0.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others M.R.H(h) - 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Partially Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: HybridMW OH Soffit Load: 2.0 PSF Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2 --------------Reaction Summary(Lbs)- -------------- TrussSp4an Limit Actual(in) Location 2x4 SP (ALSC6-2013) #1 1-4 Jnt--X-Loc- React -Up- --Width- -R qd -Mat PSI Vert LL L/360 L/999(-0.28) 12-14 BC 2x4 SP (ALSC6-2013) #2 1 04-00 1261 678 08-00 02 00 SPF 425 Vert CR L/240 L/578(-0.63) 12-14 2x4 SP (ALSC6-2013) #1 1-13 17 31-02-12 2349 1146 08-00 03 11 SPF 425 Webs 2x9 SP (ALSC6-2013) #2 11 36-04-02 148 635 08-00 00 04 SPF 425 Horz LL 0.75in ( 0.15) @Jtll 2x6 SP (ALSC6-2013) #2 17-10 Max Hobiz = -293 / +282 at Joint 1 Horz CR 1.25in ( 0.30) @Jtll Wedge 2x4 SP (ALSC6-2013) #2 Other 2x4 SP (ALSC6-2013) #2 Loads Summary This truss has been designed for the effects of an unbalanced top chord Member Forces Summary live load occurring at [180400] usin a 1.00 Full and 0.00 Reduced load Vert CR and Horz CR are the vertical and .r.Mem... Ten Comp .CSI. factor. horizontal deflections due to live load TC OH- 1 49 0 0.41 plus the creep component of deflection 1- 2 2920 3754 0.76 See Loadcase Report for loading comb nations and additional- details. due to dead load, computed as Defl LL + 2- 3 2604 3493 0.65 Dead Loads may be slope adjusted: > 2.0/12 (Kcr - 1) x Defl_DL in accordance with 3- 4 1777 2397 0.56 ANSI/TPI 1. 4- 5 1789 2351 0.54 5- 6 1901 2316 0.47 Notes 6- 7 1234 1333 0.37 Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 Bracing Data Summary 7- 8 1241 1485 0.56 degrees ------------Bracing Data------------ 8- 9 1226 1519 0.74 Plates located at TC pitch breaks me t the prescriptive minimum size Chords; continuous except where shown 9-10 742 888 0.67 requirement to transfer unblocked ditaphragm loads across those joints. Web Bracing -- None 10-11 1885 1431 0.94 1L-OH 51 0 0.56 Plate offsets (X, Y): BC 1-12 3483 11-13 2433 0.74 1679 0.32 (None unless indicated below) 12-13 3033 1985 0.56 Jnt6(0,-00-05), Jntll(-01-07,00-09), 13-14 3057 1982 0.87 Jntl3(-00-02,00-12), Jntl4(0,-00-01), 14-15 1792 734 0.50 Jntl6(00-07,-00-01), Jntl7(0,-00-13), 1Sf 16 782 254 0.43 Jntl(09-15,03-03) 16-17 1578 1726 0.32 Web 2-12 421 226 0.07 3-12 456 3-14 950 72 0.10 849 0.42 L. G / n/ 5-14 280 150 0.05 \\ ••,,,••_• \\ - Yv •' •., j 6-14 1438 6-15 433 1039 0.32 763 0.37 �� \,tGENSF' �,••• ••,� 7-15 322 138 0.07 9-15 634 9-16 779 260 0.14 860 0.19 l _ * No. 76864 '•: ,* _ 10-16 2483 1815 0.95 10-17 1617 1861 0.20 ^ ••0 Q 4;Tw %NAL E \\ / / t5/23/2018 COA #30003 NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by th• Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. Aseal on this drawing indicates acceptance of ® Component Solutions professional engineering responsibility solely for the truss component design shown. See the cover page and th "Important additional information. All connector shall be manufactured by Simpson Strong Company, Inc in Information & General Notes page for ESR-2762. Truss Studio Truss Studio v 2018.1.0. plates -Tie accordance unless the specified plate size is followed by a "-18" which indicates an 18 gauge plate, er "S# 18", which indicates a with All connector plates are 20 gauge high tension 18 gauge plate. 4 r 1-866 252 1-866-252-8606 a CSBelpsk: Project Name: 00280 - Hancock Residence -Tree Top Trail I Qty: 1 Truss: A2A Customer: Gillespie Builders SID: 0000258535 TID: 66489 Date: 05 / 23 / 18 Truss Mfr. Contact: Rick Mills Page: 1 of 1 2-0-0 6-1-3 5-5-7 5-5-7 2-8-0 5-5-7 5-5-7 6-1-3 6-1-3 11-6-9 17-0-0 19 8-0 25-1-7 30-6-13 36-8-0 1 2 3 4 5 6 7 8 9 10 4x6 4x6 3x6 3x6 5/12 3x6 3x4. -5/12 � r ^ 2x3o n � m 2x3'l i N W 4-1 3x8 3x8 4-1 3x4= 3x6 3x6 3x6 3x4= 8„ 3x4= • 8-9-14 8-2-2 2 18-2-20 8-9-14 1 1 1 8-9-14 17-0-0 19-8-0 27-10-2 36-8-0 1 11 12 13 14 15 16 10 3 -8-0 Plates -- Simpson Strong -Tie 20 ga (AS20) or 18 ga (AS18HS, AS18S5, or AS18S6) Indicated by '-18, Code/Design: FBC-2017/TPI-2014 -----------Snow Load Specs ----------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-10 Ground Snow(Pg) = N/A ASCE7-10 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 0.0 ft B = 0.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others M.R.H(h) =. 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) - 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: HybridMW OH Soffit Load: 2.0 PSF Material Summary Reaction Summary Deflection Summary TC 2x9 SP (ALS06-2013) #2--------------Reaction Summary(Lbs)- -------------- TrussSITan Limit Actual(in) Location 2x4 SP (ALSC6-2013) #1 1-4 Jnt--X-Loc- React -Up- --Width- -R qd -Mat PSI Vert LL L/360 L/999(-0.21) 11-13 BC 2x4 SP (ALSC6-2013) #1 1 03-14 1607 850 08-00 02 08 SPF 425 Vert CR L/240 L/903(-0.47) 11-13 2x4 SP (ALSC6-2013) #2 12-15 10 36-06-08 1453 733 03-00 H R SPF 565 Webs 2x4 SP (ALSC6-2013) #2 Max Horiz = -265 / +312 at Joint 1 Horz LL 0.75in ( 0.13) @Jt 1 Horz CR 1.25in ( 0.19) @Jt 1 Member Forces Summary Loads Summary ..Mem... Ten Comp .CSI. This truss has been designed for the effects of an unbalanced top chord TC OH- 1 51 0 0.41 live load occurring at [180400] usin a 1.00 Full and 0.00 Reduced load 1- 2 2511 2989 0.95 factor. Vert CR and Horz CR are the vertical and 2- 3 2350 2752 0.68 horizontal deflections due to live load 3- 4 1922 2072 0.63 See Loadcase Report for loading comb' nations and additional details. plus the creep component of deflection 4- 5 1938 2044 0.67 Dead Loads may be slope adjusted: > 2.0/12 due to dead load, computed as Defl LL + 5- 6 1863 1843 0.52 (Kcr - 1) x Defl_DL in accordance with 6- 7 1927 2041 0.69 ANSI/TPI 1. 7- 8 1911 2073 0.83 Notes 8- 9 2472 2852 0.92 Plates designed for Cq at 0.80 and tational Tolerance of 10.0 9-10 2678 3122 0.83 degrees Bracing Data Summary BC 1-11 2685 2154 0.80 Plates located at TC pitch breaks meet the prescriptive minimum size ------------Bracing Data ------------ 10-16 2827 2347 0.77 requirement to transfer unblocked diaphragm loads across those joints. Chords; continuous except where shown 11-12 2320 1765 0.65 Web Bracing -- None 12-13 2320 1765 0.70 1.q-14 1837 1225 0.63 Plate offsets (X, l): 14-15 2357 1815 0.68 15-12357 10.72 (None unless indicated below) Web 2-11 917 273 0.07 73 Jntl(00-02,0), Jnt10(-00-02,0) 3-11 441 157 0.10 3-13 720 646 0.62 1-13 548 454 0.39 5-14 199 176 0.19 6-14 544 450 0.39 8-14 784 692 0.66 8-16 501 292 0.13 \\ L. G V \ 9-16 520 342 0.09 ......... ���! ��'• ��/� No. 76864 F COA #30003 5/23/2018 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by lh Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. Component Solutions A seal on this drawing indicates acceptance professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important of Truss Studio V Information ll General Notes" page for additional information. All connector plates shad be manufactured by Simpson Strong -Tie Company, Inc in accordance by 2018.1.0.87 with ESR-2762. All connector plates are 20 gauge unless the specified plate size is followed by a "-18" which indicates an 18 gauge plate, or "S# 18", which indicates a � r Helpdesk: 1-866-252-8606 high tension 18 gauge plate. 1-866 252 ® CSHelpsk: Project Name: 00280- Hancock Residence - Tree Top Trail Qty: 1 Truss: A3 Customer: Gillespie Builders SID: 0000258536 TID: 66489 Date: 05 / 24 / 18 Truss Mfr. Contact: Rick Mills Page: 1 of 1 2-0-0 5-4-12 4-8-14 4-8-14 3-5-8 3-5-8 4-7-4 4-11-4 5-4-0 2-0-0 5-4-12 10-1-10 14-10-8 18-4-0 1-9-8 26-4-12 31-4-0 36-8-0 1 2 3 4 5 6 7 89 10 11 4x6 3x4= 4x4= 3x6 SxSa 5/12 3x6 3x6 -5/12 2x3= 2x31 ^ O 5x10 , 4x12 3x10-18 H 3x8 3x4= 4-1 3x4-- n 4-1 X 2.5/12 -2.5/12 Sx12 8 31-4-0 8" 8-2-15 7-7-1 5-11 8 9-2-8 5-8-0 8-2-15 15-10-0 21-9 8 31-0-0 36-8-0 1 12 13 14 15 16 it 36-8- Plates -- Simpson Strong -Tie 20 ga (AS20) or 18 ga (AS18HS, AS18S5, or AS18S6) Licated by 1-181 Code/Design: FBC-2017/TPI-2014 -----------Snow Load Specs ----------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-10 Ground Snow(Pg) = N/A ASCE7-10 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 0.0 ft B = 0.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Partially Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: HybridMW OH Soffit Load: 2.0 PSF Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2--------------Reaction Summary(Mbs)-- ------------- TrussSpan Limit Actual(in) Location 2x4 SP (ALSC6-2013) #1 1-4 Jnt--X-Loc- React -Up- --Width- -Re d -Mat PSI Vert LL L/360 L/999(-0.30) 12-14 BC 2x4 SP (ALSC6-2013) #1 1 04-00 1266 683 08-00 02- 0 SPF 425 Vert CR L/240 L/564(-0.64) 12-14 2x4 SP (ALSC6-2013) #2 14-16 16 31-01-12 2275 1093 08-00 03- 9 SPF 425 16-11 11 36-04-02 113 564 08-00 00-3 SPF 425 Horz LL 0.75in ( 0.20) @Jtl6 Wpbs 2x4 SP (ALSC6-2013) #2 Max Horiz = -259 / +248 at Joint 1 Horz CR 1.25in ( 0.38) @Jtl6 2x6 SP (ALSC6-2013) #2 16-10 Wedge 2x4 SP (ALSC6-2013) #2 Loads Summary Member Forces Summary This truss has been designed for the live ffects of an unbalanced top chord Vert CR and Horz CR are the vertical and .-Mem... Ten Comp .CSI. load occurring at [1804001 using factor. a 1.00 Full and 0.00 Reduced load horizontal deflections due to live load TC OH- 1 49 0 0.41 plus the creep component of deflection 1- 2 2900 3764 0.76 See Loadcase Report for loading combippations and additional details. due to dead load, computed as Defl LL + 2- 3 2596 3513 0.59 Dead Loads may be slope adjusted: > 12.0/12 (Kcr - 1) x Defl_DL in accordance with 3- 4 1821 2513 0.50 ANSI/TPI 1. 4- 5 1836 2494 0.53 5- 6 1862 2441 0.41 Notes 6- 7 1127 1249 0.32 Plates designed for Cq at 0.60 and Ro ational Tolerance of 10.0 Bracing Data Summary 7- 8 1137 1397 0.46 degrees ------------Bracing Data ------------ 8- 9 1122 1412 0.48 Plates located at TC pitch breaks mee the prescriptive minimum size Chords; continuous except where shown 9-10 1774 1123 0.93 requirement to transfer unblocked dia hragm loads across those joints. ------- Web Bracing -- CLR----------- 10-11 1782 1308 0.95 Continuous Lateral Restraint (CLR) ro s require diagonal bracing per Single: 9-16 11;-OH 51 0 0.56 D-WEBCLRBRACE. Alternatively, see D- BREINFORCE. Continuous Restraint Bracing Req'd BC 1-12 3491 2415 0.73 See BCSI-B3 3.0 11-16 1423 1580 0.46 12-13 3135 2049 0.59 Plate offsets �v V1 t 13-14 1954 2928 0.95 14-16 1539 0.73 (None unless indicated below) 12-12 539 139 0.06 Jntll(-01-08,00-10q), Jntl4(0,-01-01), Web 2-12 384 271 0.06 271 Jnt16(-00-01,-001161)IIJ � (09-15,03-03) 1 3-12 381 0 0.08 3-14 923 826 0.49 5-14 728 420 0.16 6-14 801 419 0.18 \\ {� v 6-15 715 1033 0.50 7-15 308 130 0.07 �/ oDENS ,t,, 9-15 862 362 0.19 9-16 2110 2799 0.52 10-16 496 381 0.06 No. 76864 '•. P Q ST E F NAB \\� / / / I I I 1 i5/23/2018 COA N30003 NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by lh Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of Component Solutions professional engineering responsibility solely for the truss component design shown. See the cover page and the" - ortant Information & General Notes' page for Truss Studio V additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge 2018.1.0.87Stud unless the specified plate size is followed by a'-18' which indicates an 18 gauge plate, or •S# 18", which indicates a high tension 18 gauge plate. 1-866-252-8606 CSHelp@strongtio.com Project Name: 00280 - Hancock Residence - Tree Top Trail I Qty: 1 Truss: A3A Customer: Gillespie Builders SID: 0000258537 TID: 66489 Date: 05 / 23 / 18 Truss Mfr. Contact: Rick Mills Page: 1 of 1 ,2-0-0. 5-5-3 4-9-1 4-9-7 3-4-0 l 3-4-0 4-9-7 4-9-7 5-5-3 FF 5-5-3 1 1 10-2-9 15-0-0 18-4-0 1 21-8-0 26-5-7 31-2-13 36-8-0 1 2 3 4 5 � 7 8 9 10 11 4x6 3x4- 4x6 3x6 3x6 5/12 3x6 -5/12 3x6 2x3o 2x3% 10 v n 4-1 3x8 3x8 4-1 wr 5x5= 3x6 3x6 3x6 3x4 8„ ` 7-8-10 7-3-6 6-,8-0 7-3-6 7-8-10 7-8-10 1 1 15-0-0 21i8-0 1 28-11-6 36-8-0 1 �F 12 13 14 15 16 11 36� 8-0 Plates -- Simpson Strong -Tie 20 ga (AS20) or 18 go (AS18HS, AS18S5, or AS18S6) ndicated by '-18' Code/Design: FBC-2017/TPI-2014 -----------Snow Load Specs ----------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-10 Ground Snow(Pg) = N/A ASCE7-10 Wind Speed(V) = 170 mph 10 ps£ Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 0.0 ft B = 0.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Pit 1.25 1.60 N/A Thermal Condition: All Others M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 O.C. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No 'Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: HybridMW OH Soffit Load: 2.0 PSF Material Summary Reaction Summary Deflection Summary TC 2x9 SP (ALSC6-2013) #2 --------------Reaction Summary(Lbs)-- ------------- TrussSpan Limit Actual'(in) Location 2x4 SP (ALSC6-2013) #1 1-4 Jnt--X-Loc- React -Up- --Width- -Re d -Mat PSI Vert LL L/360 L/999(-0.21) 12-13 BC 2x4 SP (ALSC6-2013) #2 1 03-14 1607 850 08-00 02- 8 SPF 425 Vert CR L/240 L/954(-0.45) 12-13 2x4 SP (ALSC6-2013) #1 1-12 11 36-06-08 1453 733 03-00 HG SPF 565 Webs 2x4 SP (ALSC6-2013) #2 Max Horiz = -231 / +277 at Joint 1 Horz LL 0.75in ( 0.07) @Jtll � Horz CR 1.25in ( 0.15) @Jtll Member Forces Summary Loads Summary ..Mem... Ten Comp .CSI. This truss has been designed for the effects of an unbalanced top chord TC OH- 1 51 0 0.41 live load occurring at (180400] using a 1.00 Full and 0.00 Reduced load 1- 2 2979 2999 0.90 factor. Vert CR and Horz CR are the vertical and 2- 3 2357 2811 0.59 horizontal deflections due to live load 3- 4 2015 2258 0.55 See Loadcase Report for loading combinations and additional details. plus the creep component of deflection 4- 5 2031 2242 0.60 Dead Loads may be slope adjusted: > 2.0/12 due to dead load, computed as Defl LL + 5- 6 1936 2021 0.50 (Kcr - 1) x Defl_DL in accordance with 6- 7 1953 2033 0.51 ANSI/TPI 1. 7- 8 2034 2249 0.61 Notes 8- 9 2020 2269 0.72 Plates designed for Cq at 0.80 and R tational Tolerance of 10.0 9-10 2508 2933 0.80 degrees Bracing Data Summary 10-11 2672 3156 0.71 Plates located at TC pitch breaks me t the prescriptive minimum size ------------Bracing Data ------------ BC 1-12 2695 2127 0.80 requirement to transfer unblocked di phragm loads across those joints. Chords; continuous except where shown 11-16 2862 2352 0.86 Web Bracing -- None 12-13 2421 1835 0.80 _ 1.�-14 2061 1433 0.74 Plate offsets (X, 1): 14-15 2061 1433 0.71 15-16 2471 1902 0.80 (None unless indicated below) Web 2-12 327 207 0.05 Jntl(00-02,0), Jntll(-00-02,0), 3-12 348 104 0.08 Jntl2(0,-01-00) 3-13 616 545 0.40 5-13 590 461 0.31 6-13 194 224 0.18 6-15 190 206 0.17 //// 7-15 589 458 0.30 9-15 684 592 0.43 \\\ L• G/ 9-16 416 254 0.09 �\ ...•••l.J/�/ // •' - vv 10-16 441 285 0.07 • i _ * : No. 76864 Q� ST E FC D \? G \� /0NAL \ ,� COA #30003 5/23/2018 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is be ad on design criteria and requirements supplied by th Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of Component Solutions professional engineering responsibility solely for the truss component design shown. See the cover page and the Important Information 8 General Notes" page for TrussSt St. Truss Studio V additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge 2018.1.0 .87 unless the specified plate size is followed by a'-18• which indicates an 18 gauge plate, or"S# 18", which indicate$ a high tension 18 gauge plate. � r Helpdask:1-861-8666-252 252 -8606 Project Name: 00280- Hancock Residence - Tree Top Trail City: 1 Truss: A4 Customer: Gillespie Builders SID: 0000258538 TID: 66489 Date: 05 / 24 / 18 Truss Mfr. Contact: Rick Mills Page: 1 of 1 2-0-0, 5-4-0 7-6-8 5-5-8 5-5-8 7-6-8 5-4-0 2-0-0, 5-4-0 1 12-10-8 18-4-0 23-9-8 31-4-0 1 36-8-0 T 1 2 3 4 5 6 7 8 9 4x6 201 4x6 5/12 -5/12 4x6 3x6 ^ � m 3x4= 4x4_- m � 4_1 3x4= 4-1 �74=IJ Z C: 2x3l 3x6 3x8 4x4 3x6 8" 31-4-0 8" 3x4= 3x6 5-4-0 7-6-8 5-5-8 5-5-8 7-6-8 5-4-0 5-4-0 12-10-8 18-4-0 23-9-8 31-4-0 36-8-0 1 10 11 12 13 14 15 16 9 36-8-0 Plates -- Simpson Strong -Tie 20 ga (AS20) or 18 ga (AS18HS, AS18S5, or AS18S6) i dicated by '-18' Code/Design: FBC-2017/TPI-2014 -----------Snow Load Specs ----------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Our Factors ASCE7-10 Ground Snow(Pg) = N/A SCE7-10 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 0.0 ft B = 0.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2=00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Partially Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: HybridMW OR Soffit Load: 2.0 PSF Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6"-2013) #2--------------Reaction Summary(Lbs)-= ------------- TrussS pan Limit Actual(in) Location 2x4 SP (ALSC6-2013) #1 7-9 Jut--X-Loc- React -Up- --Width- -Re d -Mat PSI Vert LL L/360 L/999(-0.14) 10-12 BC 2x4 SP (ALSC6-2013) #2 1 03-14 1339 712 08-00 02- 2 SPF 425 Vert CR L/240 L/999(-0.33) 10-12 2x4 SP (ALSC6-2013) #1 1-11 16 31-04-00 1832 933 08-00 02- 4 SPF 425 Webs 2x4 SP (ALSC6-2013) #2 9 36-04-02 130 188 08-00 00- 3 SPF 425 Horz LL 0.75in ( 0.11) @Jt 1 • 2x6 SP (ALSC6-2013) #2 10-2 Max Horiz = -224 / +210 at Joint 1 Horz CR 1.25in ( 0.14) @Jt 1 16-8 Loads Summary Member Forces Summary This truss has been designed for the ffects of an unbalanced top chord ..Mem... Ten Comp .CSI. live load occurring at (180400] using a 1.00 Full and 0.00 Reduced load Vert CR and Horz CR are the vertical and TG OH- 1 51 0 0.56 factor. horizontal deflections due to live load 1- 2 1910 2478 0.97 plus the creep component of deflection 2- 3 1498 1850 0.91 See Loadcase Report for loading combi ations and additional details. due to dead load, computed as Defl LL + 3- 4 1519 1808 0.98 Dead Loads may be slope adjusted: > 1 0/12 (Kcr - 1) x Defl_DL in accordance with 4- 5 1442 1552 0.62 ANSI/TPI 1. 5- 6 1443 1552 0.65 6- 7 1020 1216 0.85 Notes 7- 8 999 1258 0.75 Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 Bracing Data Summary 8- 9 769 678 0.68 degrees I ------------Bracing Data ------------ 9-OH 51 0 0.41 Plates located at TC pitch breaks meet the prescriptive minimum size Chords; continuous except where shown BC 1-10 2239 1513 0.77 requirement to transfer unblocked dia,hragm loads across those joints. ------- Web Bracing -- CLR----------- 9-16 826 636 0.36 Continuous Lateral Restraint (CLR) ro s require diagonal bracing per Single: 14- 8 1Q-11 2239 1514 0.50 D-WEBCLRBRACE'. Alternatively, see D- BREINFORCE. Continuous Restraint Bracing Req'd 11-12 2239 1514 0.78 See BCSI-B3 3.0 12-13 1620 910 0.69 13-14 1077 461 0.56 Plate offsets (X, l): 14-15 827 638 0.31 (None unless indicated below) 15-16 827 638 0.36 Web 2-10 214 0 0.03 Jntl(01-10,00-13), Jnt3(00-02,-00-04) 2-12 628 641 0.66 4-12 423 144 0.09 /// 4-13 158 234 0.22 \\\ �/ L• G/ i ///j 6-13 653 515 0.49 \1\ ^�\•••••••••lJ^/� •,•• 6-14 453 383 0.19 8-14 1781 1341 0.40 \-\CENSF �\ �;•,� i 8-16 1611 1689 0.20 * ; No. 76864 4��_r • G\ ZONAL 6 coA#soo 323/2018 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by th Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of Component Solutions Fr1r, Mrs InTruss professional engineering responsibility solely for the truss component design shown. See the cover page and the'ITportant Information 8 General Notes' page for Truss Studio Studio V additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge 2018.1. 0.87 unless the specified plate size is followed by a'-18" which indicates an 18 gauge plate, or-S# 18", which indicates r high tension 18 gauge plate. Helpdesk:1-866-252-8606 1-866 252 Project Name: 00280 - Hancock Residence - Tree Top Trail I Qty: 1 Truss: A4A Customer: Gillespie Builders SID: 0000258539 TID: 66489 Date: 05 / 23 / 18 Truss Mfr. Contact: Rick Mills Page: 1 of 1 2-Plv 2-0-0 6- -1 6-2-2 5-4-0 5- -0 3-11-0 3-4-0 5-10-8 3-2-8 2-0-0 ' 6-9-14 13-0-0 18-4-0 23-8-0 27-7-0 30-11-0 36-9-8 40-2Z1 1 2 3 4 5 6 7 8 9 10 -5/12 4x6 3x4= 4x6 5/12 3x6 4x12 4x6 -5/12 N 3x4= m •� 4x4c a0 i 4-1 3x6 v O 4x8 4 1 X 8„ 2x4 3x4= 3x6 3x4= 3x8 7x8= 3x8 3x6 8„ d - 3185# 6-9-14 6-2-2 5-4-0 5- -0 3-11-0 3-4-0 5-10-8 6-9-14 13-0-0 T_4-0 23 8-0 27-7-0 30-11-0 36-9-8 40-0-0 • 1 11 12 13 14 15 16 17 18 10 k 40-0- Plates -- Simpson Strong -Tie 20 ga (AS20) or 18 ga (AS18HS, AS18S5, or AS18S6) i dicated by '-18' Code/Design: FBC-2017/TPI-2014 -----------Snow Load Specs----------- I[' -----Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-10 Ground Snow(Pg) = N/A 7�SCE7-10 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C isk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered 1dg Dims: L = 0.0 ft B = 0.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others .R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c- Plies: 2 Unobstructed Slippery Roof: No ldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: No Low -Slope Minimums(Pfmin): No ind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No nd Vertical Exposed: L - Yes R - Yes Fab Tolerance: 20`i Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chic: No ind Uplift Reporting: HybridMW OR Soffit Load: 2.0 PSF Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2 --------------Reaction Summary(Lbs)-- ------------- TrussSpan Limit Adtual(in) Location BC 2x4 SP (ALSC6-2013) #2 Jnt--X-Loc- React -Up- --Width- -Re d -Mat PSI Vert LL L/360 L/999(-0.25) 14-15 2x6 SP (ALSC6-2013) DSS 1 03-14 1960 1028 ' 08-00 01- 9 SPF 425 Vert CR L/240 L/895(-0.52) 14-15 16-10 10 39-08-00 4680 2402 08-00 03- 1 SPF 425 Webs 2x4 SP (ALSC6-2013) 1,2 Max Horiz = -238 / +214 at Joint 1 Horz LL 0.75in ( 0.08) @Jt10 Horz CR 1.25in ( 0.17) @JtlO Member Forces Summary Loads Summary ..Mem... Ten Comp .CSI- This truss has been designed for the ffects of an unbalanced top chord TC OH- 1 51 0 0.32 live load occurring at [180400] using a 1.00 Full and 0.00 Reduced load 1- 2 2 30. factor. Vert CR and Horz CR are the vertical and 2- 3 2604 4 97 3347 0.52 horizontal deflections due to live load 3- 4 2618 3296 0.53 See Loadcase Report for loading combigqations and additional details. plus the creep component of deflection 4- 5 2874 3567 0.47 Dead Loads may be slope adjusted: > 12.0/12 due to dead load, computed as Defl LL + 5- 6 2938 3730 0.41 Concentrated Loads - Based on Live Lodd (Kcr - 1) x Defl_DL in accordance with 6- 7 3115 4099 0.40 Domain Load Uplift Location Dir Description ANSI/TPI 1. 7- 8 3732 5063 0.57 Transfer loads: 8- 9 3681 5385 0.63 BC 3185 -1621 36-09-08 Vert B1 @ -90 Deg 9-10 5730 9613 0.66 Bracing Data Summary 10-OH 53 0 0.33 2-PLY TRUSS Fastener Spacing ------------Bracing Data---------- BC 1-11 3460 2358 0.81 Fasten each ply to the adjacent ply as follows(rows staggered): Chords; continuous except where shown 10-18 8831 5082 0.55 TC, 1-rows) of 10d Nails (0.120" dia x 2-7/8" min.) @ 12.0" o.c. Web Bracing -- None 11-12 3460 2358 0.52 BC 2x4, 1-row(s) of lid Nails (0 .120" dia. x 2-7/8" min.) @ 12.0" o.c. 12-13 3012 1873 0.45 BC 2x6, 2-row(s) of 10d Nails (0 .120" dia. x 2-7/8" min.) @ 12.0" o.c.** Plate offsets (X, Y): 13-15 3568 14-16 2244 0.49 2270 0.78 WB, 1-row(s) of 10d Nails (0.120, dia x 2-7/8" min.) @ 9.0" o.c. (None unless indicated below) 15-16 5074 5074 3270 0.78 ** Use additional fasteners of the s ie type within +/-12" of the Jnt7(0,01-08), Jntl7(00-08,0), 16-17 4883 3009 0.26 location(s) indicated (except where aiproved hangers are used with Jnt18 (0,-01-10) 17-18 8833 5083 0.55 fasteners that transfer the load to all plies): Web 2-11 203 0 0.02 2-12 534 525 0.06 BC:36-09-08, 17 4-12 410 204 0.09 4-19 865 5-14 419 517 0.09 492 0.04 Notes 5-15 469 332 0.05 Plates designed for Cq at 0.80 and Rotational degrees Tolerance of 10.0\�\ 2��.••••••••�• y�/��� 6-15 1288 857 0.14 Plates located at TC pitch breaks meet the prescriptive minimum size \ !G •••��CENSF ''•� i �•••• •••� 7-15 1396 1948 0.14 requirement to transfer unblocked diaphragm loads across those joints. 7-16 365 8-16 428 8-17 1462 358 0.03 344 0.03 721 0.16 1 No. 76864 ••: *, 7C 9-17 2185 4068 0.32 = - 9-18 2369 1262 0.26 Q ST E ONAL. E.. / I I I I t5/23/2018 CO A #30003 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by lh Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. Aseal on this drawing indicates acceptance of Component Solutions professional engineering responsibility sole) for the truss component design shown. See the cover page and the "I P 9 9 P tY Y Po 9 P 9 fnP ortant Information & General Notes' page for P 9 Truss Studio V 2018.1.0 2018.1.0.87 additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge r . unless the specked plate size is followed by a "-18"which indicates an 18 gauge plate, or •S# 18•, which indicates 3 high tension 18 gauge plate. Helpdesk:1-8666 -252-8606 CSHelp@strongtie.com m corn Project Name: 00280 - Hancock Residence - Tree Top Trail I Qty: 1 Truss: A5 Customer: Gillespie Builders SID: 0000258540 TID: 66489 Date: 05 / 23 / 18 Truss Mfr. Contact: Rick Mills Page: 1 of 1 2-0-0 5-9-14 5-2-2 4-10-11 4-10-11 4-10-11 5-2-2 5-9-14 2-0-0 il 5-9-14 11-0-0 15-10-11 20-9-5 25-8-0 30-10-2 36-8-0 1 2 3 4 5 6 7 B 4x6 3x4= 2x3i 4x6 5/12 -5/12 3x4% 3x4-- 10 4-1 3x8 3x8 4-1 X 2x3i 3x4 3x6 3x4= 3x6 3x6 3x4= 2x31 8„ 8„ 5-9-14 5-2-2 4-10-11 4-10-1 4-10-11 5-2-2 5-9-14 5-9-14 11-0-0 15-10-11 20-9-5 25-8-0 30-10-2 36-8-0 1 9 10 it 12 13 14 15 16 8 36-8-0 Plates -- Simpson Strong -Tie 20 ga (AS20) or 18 ga (AS18HS, AS18S5, or AS18S6) i dicated by 1-18' Code/Design: FBC-2017/TPI-2014 -----------Snow Load Specs----------- -------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-10 Ground Snow(Pg) = N/A SCE7-10 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C isk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered 1dg Dims: L = 0.0 ft B = 0.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others .R.H(h) = 15.0 ft Kzt = 1-0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No End DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: HybridMW OH Soffit Load: 2.0 PSF Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #1--------------Reaction Summary(Lbs)-- ------------- TrussSpan Limit Actual(in) Location 2x4 SP (ALSC6-2013) 02 3-6 Jot--X-Loc- React -Up- --Width- -Re d -Mat PSI Vert LL L/360 L/999(-0.25) 12-13 BC 2x4 SP (ALSC6-2013) #1 1 03-14 1594 842 08-00 02- 8 SPF 425 Vert CR L/240 L/830(-0.51) 12-13 2x4 SP (ALSC6-2013) #2 11-14 8 36-04-02 1594 836 08-00 02- 8 SPF 425 Webs 2x4 SP (ALSC6-2013) #2 Max Horiz = -192 / +177 at Joint 1 Herz LL 0.75in ( 0.07) @Jt 8 Herz CR 1.25in ( 0.15) @it 8 Member Forces Summary Loads Summary ..Mem... Ten Comp .CSI. This truss has been designed for the ffects of an unbalanced top chord TC OH- 1 51 0 0.41 live load occurring at (180400] using a 1.00 Full and 0.00 Reduced load 1- 2 2319 2960 0.79 factor. Vert CR and Herz CR are the vertical and 2- 3 2139 2589 0.52 horizontal deflections due to live load 3- 4 2365 2736 0.66 See Loadcase Report for loading combi ations.and additional details. plus the creep component of deflection 4- 5 2364 2735 0.61 Dead Loads may be slope adjusted: > 1 .0/12 due to dead load, computed as Defl LL + 5- 6 2365 2736 0.66 I (Kcr - 1) x Defl_DL in accordance with 6- 7 2130 2589 0.52 ANSI/TPI 1. 7- 8 2310 2960 0.78 Notes 8-OH 51 0 0.41 Plates designed for Cq at 0.80 and RoIlt ational Tolerance of 10.0 BC 1- 9 2662 1862 0.84 degrees Bracing Data Summary 8-16 2662 1866 0.84 Plates located at TC pitch breaks me e the prescriptive minimum size ------------Bracing Data ------------ 9-10 2662 1862 0.52 requirement to transfer unblocked dia hragm loads across those joints. Chords; continuous except where shown 10-11 2325 1510 0.44 Web Bracing -- None 11-12 2325 1510 0.53 12-13 2736 1827 0.66 Plate offsets (X, l): 13-14 2326 1513 0.53 14-15 2326 10. (None unless indicated below) 15-16 2662 1866 0.5522 66 Jntl(00-02,0), Jnt8(-00-02,0) Web 2- 9 154 0 0.03 2-10 389 391 0.22 3-10 350 157 0.08 3-12 551 425 0.30 4-12 341 276 0.10 //// 4-13 243 244 0.17 5-13 339 276 0.10 \\� �/ L• G,/ I �\•,•....,•l•1/y� \\ �Q0.30 6-15 350 158 0.08 7-15 390 391 0.22 \CENS �; •••••� 7-16 154 0 0.03 * ; No. 76864 NAI 0 C on #30003 5123/2018 NOTICE A copy of this design shall be fumished to the erection contractor. The designof this individual truss is based on design criteria and requirements supplied by th Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance Component Solutions ® of professional engineering responsibility solely for the truss component design shown. See the cover page and the 'Important Information & General Notes" page for Truss Studio V additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accorda2ce with ESR-2762. All connectorplates are 20 gauge 2018.1.0.87 r 0. unless the specified plate size is followed by a "-18" which indicates an 18 gauge plate, or'S# 18", which indicates a high tension 18 gauge plate. H018.1. 1-866-252-8606 1-8i6 252 ® CSHelpsk: Project Name: 00280 - Hancock Residence - Tree Top Trail I Qty: 1 Truss: A5A Customer: Gillespie Builders SID: 0000258541 TID: 66489 Date: 05 / 23 / 18 Truss Mfr. Contact: Rick Mills Page: 1 of 1 2-0-0 5-9-14 5-2-2 6-0-0 6-0-0 6-0-0 5-2-2 5-9-14 2-0-0 5-9-14 11-0-0 17-0-0 23-0-0 29-0-040-0-0 1 2 3 4 5 6 7 8 4x8 3x4- 5x5= 4x8 ' 5/12 -5/12 3x4% 3x4-. � m a cO 4-1 3x8 3x8 4-1 2x4 3x4= 3x6 3x4= 3x8 3x6 3x4= 2x4 8„ 8„ 5-9-14 5-2-2, 6-0-0 6-0-0 6-0-0 5-2-2 5-9-14 5-9-14 11-0-0 17-0-0 23-0-0 29-0-0 34-2-2 40-0-0 1 9 10 11 12 13 14 15 16 8 40-0-0 Plates -- Simpson Strong -Tie 20 ga (AS20) or 18 ga (AS18HS, AS18S5, or AS18S6) i dicated by '-18' Code/Design: FBC-2017/TPI-2014 -----------Snow Load Specs ----------- ---------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-10 Ground Snow(Pg) = N/A �SCE7-10 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 0.0 ft B = 0.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No ldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No Fnd Vertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No find Uplift Reporting: HybridMW OR Soffit Load: 2.0 PSF Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #1 --------------Reaction Summary(Lbs)--- ------------ TrussSpan Limit Actual(in) Location 2x4 SP (ALSC6-2013) #2 3-5 Jnt--X-Loc- React -Up- --Width- -Req -Mat PSI Vert LL L/360 L/999(-0.33) 12-13 5-6 1 03-14 1727 909 08-00 02-1 SPF 425 Vert CR L/240 L/685(-0.68) 12-13 BC 2x4 SP (ALSC6-2013) 01 8 39-08-02 1728 903 08-00 02-1 SPF 425 2x4 SP (ALSC6-2013) #2 11-14 Max Horiz = -198 / +183 at Joint 1 Horz LL 0.75in ( 0-09) @Jt 8 Sdebs 2x4 SP (ALSC6-2013) #2 Horz CR 1.25in ( 0.17) @Jt 8 Loads Summary Member Forces Summary This truss has been designed for the a facts of an unbalanced top chord ..Mom... Ten Comp .CSI. live load occurring at (200000] using a 1.00 Full and 0.00 Reduced load TC OR- 1 51 0 0.41 factor. Vert CR and Horz CR are the vertical and 1- 2 2564 3275 0.84 horizontal deflections due to live load 2- 3 2396 2923 0.56 See Loadcase Report for loading combin tions and additional details. plus the creep component of deflection 3- 4 2779 3270 0.82 Dead Loads may be slope adjusted: > 12�.0/12 due to dead load, computed as Defl LL + 4- 5 2779 3269 0.82 (Kcr - 1) x Defl_DL in accordance with 5- 6 2779 3270 0.81 ANSI/TPI 1. 6- 7 2387 2924 0.55 Notes 7- 8 2556 3275 0.83 Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 8-OH 51 0 0.41 degrees Bracing Data Summary BC 1- 9 2951 2086 0.93 Plates located at TC pitch breaks mee the prescriptive minimum size ------------Bracing Data ------------ 8-16 2951 2091 0.93 requirement to transfer unblocked dia hragm loads across those joints. Chords; continuous except where shown 9-10 2951 2066 0.57 Web Bracing -- None 10-11 2634 1747 0.51 1.1-12 2634 1747 0.68 Plate offsets (X, l): 12-13 3270 2242 0.80 13-19 2639 1750 0.68 (None unless indicated below) 19-15 2634 1750 0.51 Jntl (00-02, 0), Jnt5(0,01-00), 15-16 2951 2090 0.58 JntB(-00-02,0) Web 2- 9 140 0 0.03 1-10 375 369 0.21 3-10 368 145 0.08 3-12 788 612 0.56 4-12 429 350 0.13 4-13 298 300 0.27 \\ �/ L• G / ^' // /// 5-13 428 349 0.13 \\\•,... „ ••, V ?Q - T 6-13 787 608 0.56 �\ •• �,••• 6-15 368 146 0.08 ` •,� 7-15 375 369 0.21 7-16 140 0 0.03 _ * No. 76864 -,0 ST E F \ AlL tE \\\\ COA #30003 5/23/2018 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by lh Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. Aseal on this drawing indicates acceptance of E=Truss Component Solutions professional engineering responsibility solely for the truss component design shown. See the cover page and the •IrVportant Information & General Notes' page for Studio V additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge 2018.1.0.87 2018.1.0. unless the speed plate size is followed by a •-18• which indicates an 18 gauge plate, or •S# 18•, which indicates high tension 18 gauge plate. r 1-866-252-8606 ® CSHelp@strongtie.com Project Name: 00280 - Hancock Residence - Tree Top Trail Qty: 1 Truss: A6 Customer: Gillespie Builders SID: 0000258542 TID: 66489 Date: 05 / 23 / 18 Truss Mfr. Contact: Rick Mills Page: 1 of 1 2-0-0 4-9-14 4-2-2 6-2-11 6-2-11 6-2-11 4-2-2 4-9-14 2-0-0 4-9-14 9-0-0 15-2-11 21-5-5 27-8-0 31-10-2 36-8-0 1 2 3 4 56 7 8 9 4x8 3x4= 4x6 3x6 4x8 5/12 -5/12 3x4% 3x4c A H 4-1 3x8 o 3x8 4-1 ES X 2x31 3x4= 3x6 3x4= 3x8 3x6 3x4= 2x31 8„ 8„ 4-9-14 4-2-2 6-2-11 6-2-11 6-2-11 4-2-2 4-9-14 4-9-14 9-0-0 15-2-11 21-5-5 27-8-0 31-10-2 36-8-0 1 10 11 12 13 14 15 16 17 9 36-8-0 Plates -- Simpson Strong -Tie 20 ga (AS20) or 18 ga (AS18HS, AS18S5, or AS18S6) idicated by '-18' Code/Design: FBC-2017/TPI-2014 -----------Snow Load Specs----------- -----Wnd Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-10 Ground Snow(Pg) = N/A SCE7-10 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C isk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered ldg Dims: L = 0.0 ft B = 0.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others .R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No ind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No nd Vertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No ind Uplift Reporting: HybridMW ORSoffit Load: 2.0 PSF Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) 42--------------Reaction Summary(Lbs)--- -- ---------- TrussSpan Limit Actual(in) Location 2x4 SP (ALSC6-2013) #1 1-3 Jnt--X-Loc- React -Up- --Width- -Re -Mat PSI Vert LL L/360 L/999(-0.33) 13-14 BC 2x4 SP (ALSC6-2013) #1 1 03-14 1594 842 08-00 02-08 SPF 425 Vert CR L/240 L/627(-0.68) 13-14 2x4 SP (ALSC6-2013) #2 12-15 9 36-04-02 1594 836 08-00 02-018 SPF 425 Webs 2x4 SP (ALSC6-2013) #2 Max Horiz = -158 / +143 at Joint 1 Horz LL 0.75in ( 0.07) @Jt 9 Horz CR 1.25in ( 0.15) @Jt 9 Member Forces Summary Loads Summary ..Mem... Ten Comp .CSI. This truss has been designed for the ffects of an unbalanced top chord ' TC OH- 1 51 0 0.41 live load occurring at [1804001 using a 1.00 Full and 0.00 Reduced load 1- 2 22230.factor. Vert CR and Horz CR are the vertical and 2- 3 2205 5 2739 0.46 horizontal deflections due to live load 3- 4 2757 3322 0.86 See Loadcase Report for loading combinations and additional details. plus the creep component of deflection 4- 5 2756 3321 0.86 Dead Loads may be slope adjusted: > 1 .0/12 due to dead load, computed as Defl LL + 5- 6 2756 3321 0.85 (Kcr - 1) x Defl_DL in accordance with 6- 7 2757 3322 0.85 ANSI/TPI 1. 7- 8 2198 2741 0.65 Notes 8- 9 2247 2936 0.99 Plates designed for Cq at 0.80 and Ro ational Tolerance of 10.0 9-OH 51 0 0.56 degrees Bracing Data Summary BC 1-10 2644 1814 0.85 Plates located at TC pitch breaks mee- the prescriptive minimum size ------------Bracing Data ------------ 9-17 2645 1620 0.87 requirement to transfer unblocked dia hragm loads across those joints. Chords; continuous except where shown 10-11 2644 1815 0.55 Web Bracing -- None 11-12 2475 1632 0.49 L2-13 2475 1632 0.67 Plate offsets (X, Y): 13-14 3322 2293 0.82 (None unless indicated below) 19-15 2977 1637 0.67 Jntl(00-02,0), Jnt5(0,-00-04), 15-16 2477 1637 0.49 Jnt9(-00-05,00-01) 16-17 2645 1819 0.57 Web 2-10 169 48 0.03 2-11 202 206 0.08 3-11 315 82 0.07 3-13 975 761 0.64 4-13 449 364 0.09 4-14 317 319 0.26 \�\ `/ L• G/ / /// �•,..•-•..• 6-14 447 364 0.09 Q 7-14 973 755 0.64 �� �j' •'' LICENSE'•.• �A j 7-16 316 84 0.07 �: ' •'. I' 8-16 202 205 0.08 8-17 174 53 0.03 y No. 76864 y, ST p11 \ �O 11 1 i % COA#3000323/20 $ NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by lh Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. Component Solutions ® A seal on this drawing indicates professional engineering responsibility solely for the truss component design shown. See the cover page and the 'Important acceptance of Truss Studio V Information & General Notes' page for Truss t. additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance 2018.1.0. 87 with ESR-2762. All connector plates are 20 gauge unless the specified plate size is followed by a •-18' which indicates an 18 gauge plate, or'S# 18•, which indicates r r 1-866-252-8606 high tension 18 gauge plate. i . CSHelp@strangtie.com Project Name: 00280 - Hancock Residence - Tree Top Trail I Qty: 1 Truss: A6A Customer: Gillespie Builders SID: 0000258543 TID: 66489 Date: 05 / 23 / 18 Truss Mfr. Contact: Rick Mills Page: 1 of 1 2-0-0 4-9-14 4-2-2 5-6-0 5-6-0 5-6-0 5-6-0 4-2-2 4-9-14 2-0-0 4-9-14 9-0-0 14-6-0 20-0-0 25-6-0 31-0-0 35-2-2 40-0-0 1 2 3 4 5 6 8 9 4x8 3x4= 5x5= 3x4= 4x8 ' 5/12 -5/12 2x4 2x4 m 4-1 3x8 0 3x8 4-1 a X X 3x4= 3x4= 3x10-18 3x8 3x10-18 3x4= 3x4= 8„ 8„ 9-0-0 5-6-0 5-6-0 5-6-0 5-6-0 9-0-0 9-0-0 14-6-0 20-0-0 25-6-0 31-0-0 40-0-0 1 10 it 12 13 14 15 16 9 11 40-0-0 Plates -- Simpson Strong -Tie 20 ga (AS20) or 18 ga (AS18HS, AS18S5, or AS18S6) in icated by '-18' Code/Design: FBC-2017/TPI-2014 -----------Snow Load Specs----------- - --------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-10 Ground Snow(Pg) = N/A CE7-10 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 0.0 ft B = 0.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others .R.H(h) = 15.0 £t Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Green Lumber: No Increase: Yes Wet Service: No Low -Slope Minimums(Pfmin): No Unbalanced Snow Loads: No Lind DL(psf): TC = 5.0 BC = 5.0 Vertical Exposed: L = Yes R = Yes Ind Unbalanced TCLL: Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 m Rain Surcharge: No Ice DaChk: No Uplift Reporting: HybridMW OH Soffit Load: 2.0 PSF find Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #1 --------------Reaction Summary(Lbs) ---- ----------- TrussSpan Limit Actual(in) Location 2x4 SP (ALSC6-2013) 92 3-5 Jnt--X-Loc- React -Up- --Width- -Req -Mat PSI Vert LL L/360 L/999(-0.42) 13-15 5-7 1 03-14 1727 909 08-00 02-11 SPF 425 Vert CR L/240 L/550(-0.84) 13-15 BC 2x4 SP (ALSC6-2013) #1 9 39-08-02 1728 903 08-00 02-11 SPF 425 2x4 SP (ALSC6-2013) #2 12-14 Max Horiz = -162 / +148 at Joint 1 Horz LL 0.75in ( 0.10) @it 9 Vfebs 2x4 SP (ALSC6-2013) #2 Horz CR 1.25in ( 0.19) @Jt 9 Loads Summary Member Forces Summary This truss has been designed for the effects of an unbalanced top chord ..Mem... Ten Comp .CSI. live load occurring at [200000] using a1.00 Full and 0.00 Reduced load TC OH- 1 51 0 0.41 factor. Vert CR and Horz CR are the vertical and • 1- 2 2627 3293 0.98 horizontal deflections due to live load 2- 3 2409 3051 0.56 See Loadcase Report for loading combinations and additional details. plus the creep component of deflection 3- 4 3089 3744 0.86 Dead Loads may be slope adjusted: > 12.0/12 due to dead load, computed as Defl_LL + 4- 5 3342 4082 0.88 (Kcr - 1) x Defl_DL in accordance with 5- 6 3342 4083 0.88 ANSI/TPI 1. 6- 7 3092 3745 0.86 Notes 7- 8 2402 3052 0.56 Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 8- 9 2620 3293 0.98 degrees Bracing Data Summary 9-OH 51 0 0.41 Plates located at TC pitch breaks meet the prescriptive minimum size ------------Bracing Data ------------ BC 1-10 2966 2143 0.88 requirement to transfer unblocked diaphragm loads across those joints. Chords; continuous except where shown 9-16 2966 2149 0.88 Web Bracing -- None 10-11 2763 1828 0.59 11-12 3744 2626 0.58 Plate offsets (X, l): 12-13 3744 2626 0.88 (None unless indicated below) 13-14 3744 2627 0.88 Jntl(00-04,00-01), Jnt5(0,01-00), 14-15 3744 2627 0.58 Jnt9(-00-04,00-01) 15-16 2763 1832 0.59 Web 2-10 347 232 0.09 '3-10 318 18 0.07 3-11 1169 949 0.67 4-11 546 525 0.13 4-13 576 5-13 411 306 0.21 354 0.09 �•\,..•• / 6-13 577 305 0.20 �\ ..•.'V 6-15 545 525 0.13 �' ••' \�\riENSF'•.• j 7-15 1169 947 0.67 7-16 318 19 0.07 1 8-16 348 232 0.09 ,y, No. 76864 *, 1J_� \ COA #30003 5/23/2018 NOTICE A copy of this design shell be furnished to the erection contractor. The design of this individual truss is based ion design criteria and requirements supplied by th Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates Component solutions acceptance of professional engineering responsibility solely for the truss component design shown. Seethe cover page and the "Important Information 8 General Notes page for Truss Studio V additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance�wifh ESR-2762. All connector plates are 20 gauge 2018.1.0.87 2018.1. 0. unless the specified plate size is followed by a °-18' which indicates an 18 gauge plate, or "S# 18", which indicates a hl gh tension 18 gauge plate. 1-866-252-8606 1-866 252 ® CSHelpsk: Project Name: 00280- Hancock Residence - Tree Top Trail Qty: 1 Truss: A7 Customer: Gillespie Builders SID: 0000258544 TID: 66489 Date: 05 / 24 / 18 Truss Mfr. Contact: Rick Mills Page: 1 of 2 2-ply 4-0- 4 4- 4-6-6 4-6-6 -4-0-4 2-0-0 �k- F�2-0-0 4I71 1 I 02I1I -13 20-7-3 25-1 _10 I 38-0 32-7121-24 1 2 3 4 5 6 7 8 9 10 11 80# 1704 170# 170# 170# 170# 170# 170# 170# 70# 170# 170# 170# 170# 80# s/1z b b b b b b b 2x4 b b b b 8 -s/12 5x7 3x4= 3x4= x1413x4= sx7 3x4% 3x4a m 4x6 4x6 . 4-1 4-1 2x4 3x4 3x8 7x&= 7x&= 3x8 3x4= 2x4 g•• 70# 70# 70# 70# 70# 70# 70# 70# 70# 70# 70# 92# • 92# 70# 70# 4-0-4 2-11-12 4-6-6 4-6-6 4-6- 4-6-6 4-6-6 2-11-12 4-0-4 4-0-4 7-0-0 11-6-6 16-0-13 20-7 3 25-1-10 29-8-0 32-7-12 36-8-0 - 1 12 13 14 15 16 17 18 19 11 F 36-8 0 Plates -- Simpson Strong -Tie 20 ga (AS20) or 18 ga (AS18RS, AS18S5, or AS18S6) in icated by 1-18' Code/Design: FBC-2017/TPI-2014 -----------Snow Load Specs----------- -T -------- Wind Load Specs ---------- -------Additional Design Checks ------ PSF Live Dead Dur Factors ASCE7-10 Ground Snow(Pg) = N/A A CE7-10 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 0.0 ft B = 0.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: A11 Others M�R.H(h) = 15.0 £t Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 2 Unobstructed Slippery Roof: No P rtially Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: No Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No EId Vertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Uplift Reporting: HybridMW OH Soffit Load: 2.0 PSF Ind Material Summary Reaction Summary I Deflection Summary TC 2x4 SP (ALSC6-2013) #2--------------Reaction Summary(Lbs)---- ----------- TrussSpan Limit Actual(in) Location 2x6 SP (ALSC6-2013) #2 3-7 Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999(-0.39) 15-16 7-9 1 04-00 3326 2545 08-00 02-10 SPF 425 Vert CR L/240 L/523(-0.81) 15-16 BC 2x6 SP (ALSC6-2013) #2 11 36-04-00 3326 2537 08-00 02-10 SPF 425 2x6 SP (ALSC6-2013) #1 15-16 Max Horiz = -124 / +99 at Joint I Horz LL 0.75in ( 0.08) @Jtll Webs 2x4 SP (ALSC6-2013) #2 Horz CR 1.25in ( 0.18) @Jtll Loads Summary Member Forces Summary This truss has been designed for the of ects of an unbalanced top chord ..Mem... Ten Comp .CSI. live load occurring at [180400] using a 1.00 Full and 0.00 Reduced load TC OH- 1 53 0 0.33 factor. Vert CR and Horz CR are the vertical and 1- 2 6158 6977 0.73 horizontal deflections due to live load 2- 3 6596 7320 0.71 See Loadcase Report for loading combina ions and additional details. plus the creep component of deflection 3- 4 8975 9873 0.73 Dead Loads may be slope adjusted: > 12. /12 due to dead load, computed as Defl LL + 4- 5 10489 11572 0.83 Concentrated Loads - Based on Live Load (Kcr - 1) x Defl_DL in accordance with 5- 6 10492 11571 0.87 Domain Load Uplift Location Dir Description ANSI/TPI 1. 6- 7 10469 11553 0.82 Transfer loads: 7- 8 10469 11553 0.83 TC 170 -239 7-00-12 Vert J17 @ -90 Deg 8- 9 8988 9877 0.73 TC 80 -97 7-01-08 Vert J3 @ -135 Deg Bracing Data Summary 9-10 6593 7321 0.71 TC 170 -239 9-00-12 Vert J17 @ -90 Deg ------------Bracing Data ------------ 10-11 6157 6977 0.73 TC 170 -239 11-00-12 Vert J17 @ -90 Deg Chords; continuous except where shown 11-OH 53 0 0.33 TC 170 -239 13-00-12 Vert J17 @ -90 Deg Web Bracing -- None BC 1-12 6381 5408 0.83 TC 170 -239 15-00-12 Vert J17 @ -90 Deg 1, -19 6381 5424 0.83 TC 170 -239 17-00-12 Vert J17 @ -90 Deg Plate offsets (X, Y): 12-13 6382 5408 0.83 TC 170 -239 18-04-00 Vert J17 @ -90 Deg (None unless indicated below) 13-15 0.94 TC 170 -239 19-07-04 Vert J17 @ -90 Deg Jntl(01-02,00-08), Jnt3(00-03,-00-06), 9874 14-15 9879 8582 0.94 8582 TC 170 -239 21-07-09 Vert J17 @ -90 Deg Jnt9(-00-03,-00-06), 15-16 11590 10118 0.76 TC 170 -239 23-07-04 Vert J17 @ -90 Deg Jntll(-01-02,00-08), Jntl4(-00-08,0), 16-17 9876 15-18 6726 8592 0.96 5750 0.65 TC 170 -239 25-07-04 TC 170 -239 27-07-04 Vert Vert J17 @ -90 Deg J17 @ -90 De 4 Jntl5(0,-02-00), Jnt16(0,-02-00), 18-19 6381 5923 0.63 TC 80 -97 29-06-08 Vert J3 @ -45 De 4 Jnt17(00-08,0) Web 2-12 504 429 0.04 TC 170 -239 29-07-04 Vert J17 @ -90 Deg 2-13 407 3-13 293 485 0.04 99 0.04 BC 70 0 7-00-12 BC 92 -98 7-01-08 Vert Vert J17 @ -90 Deg J3 @ -135 Deg ��/•.L •, G/ I� /// 3-14 3616 3267 0.41 BC 70 0 9-00-12 Vert J17 @ -90 Deg \\\ \ �� 4-14 1736 4-15 2003 1603 0.15 1784 0.22 BC 70 0 11-00-12 BC 70 0 13-00-12 Vert Vert J17 @ -90 Deg J17 @ -90 Deg '•••\-10ENSF'•.•� �; '• 5-15 991 761 0.08 BC 70 0 15-00-12 Vert J17 @ -90 Deg ••'• 5-16 724 756 0.08 BC 70 0 17-00-12 BC 70 0 18-04-00 Vert Vert J17 @ -90 Deg J17 @ -90 Deg = 1 NO. 76864 y = 7C 6-16 982 8-16 1979 755 0.08 1749 0.22 BC 70 0 19-07-04 Vert J17 @ -90 Deg 7C 8-17 1726 1597 0.15 BC 70 0 21-07-04 Vert J17 @ -90 Deg ._ 9-17 3621 3267 0.41 BC 70 0 23-07-04 Vert J17 @ -90 Deg 9-18 292 98 0.04 BC 70 0 25-07-04 Vert J17 @ -90 Deg •'• 10-18 409 485 0.04 BC 70 0 27-07-04 Vert J17 @ -90 Deg O ST E F 10-19 503 431 0.04 BC 92 -98 29-06-08 Vert J3 @ -45 Deg '. .'\�\ BC 70 0 29-07-04 Vert J17 @ -90 Deg i��\ •••FC D COA #30003 5/23/2018 NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by th Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance Component Solutions E=Studio of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information 8 General Notes" page for Truss Truss St V additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance With ESR-2762. All connector plates are 20 gauge 2018.1.0 .87- unless the specified plate size is followed by a "-18" which indicates an 18 gauge plate, cr "S# 18", which indicates a high tension 18 gauge plate. r Helpdesk:8666 -252-8606 CSE[elp@strongtie.com • com Project Name: 00280- Hancock Residence - Tree Top Trail Qty: 1 Truss: A7 Customer: Gillespie Builders SID: 0000258544 TID: 66489 Date: 05 / 24 / 18 Truss Mfr. Contact: Rick Mills Page: 2 of 2 2-PLY TRUSS Fastener Spacing Fasten each ply to the adjacent ply as follows(rows staggered): TC, 1-row(s) of 10d Nails (0.120" dia. x 2-7/8" min.) @ 12.0" o.c. BC, 2-row(s) of 10d Nails (0.120" dia. x 2-7/8" min.) @ 12.0" o.c. WB, 1-row(s) of 10d Nails (0.120" dia. x 2-7/8" min.) @ 9.0" o.c.. Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees, ,Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked dia hra inloads across those joints. Notes P1a#es designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Less than 0.25/12 pitch requires adequate drainage to prevent ponding. .� �•. GUN //, ��`( ••��GENSF• ��, .���� * No. 76864 ONA'-5/23/2018 coA #300o3 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based op teria and irementlied by lh (' design criteria requirements supplied Component Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designed Solutions A seal on this drawing indicates acceptance of Truss Studio V ® professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance uYith Information & General Notes" page for 2018.1.0.87 ESR-2762. All connector plates are 20 gauge' r 2018.1sk: unless the specified plate size is followed by a "-18" which indicates an 18 gauge plate, or "S# 18", which indicates a high � 1-866-252-8606 tension 18 gauge plate. d CSHelp@strongtie.com Project Name: 00280- Hancock Residence - Tree Top Trail Qty: 1 Truss: A7A Customer: Gillespie Builders SID: 0000258545 TID: 66489 Date: 05 / 24 / 18 Truss Mfr. Contact: Rick Mills Page: 1 of 2 2-Ply 2-0-0 4-0-4 2: 1-12 4-4-0 4-4-0 4-4-0 4-4-0 4-4-0 4-4-0 2-11-12 4-0-4 2-0-0 4-0-4 _4 15-8-0 20-0-0 7-0-0 If 24-4-0 28-8-0 33-0-0 35-11-12 40-0-0 1 2 3 4 5 6 7 8 9 10 11 12 80# 3x8 170# _ 17�0# 170# 170# 170# 170# 17a0# 17�0# 17u0# 170# 17a0# 1710# 1 # 1710# 80u# 5/12 b6a� ! -5/12 5x7 3x4= 3x4= 2x4 14-y1 3x4= 5x7 H 3x4= I I I I n3x4-, . i 4x6 ��14 M 4x6 4-1 4-1 0 8„ 2x4 3x4= 3x8 7xl6-18 3x8 7xl6-18 3x8 3x4= 2x4 8„ b t t b 1 d d 1 b 1 1 1 8 70# 70# 70# 70# 70# 70# 70# 7 # 70# 70# 70# 70# 70# 92# 92# 70# 4-0-4 2-11-12 4-4-0 4-4-0 4-4-0 4-4-0 4-4-0 4-4-0 2-11-12 4-0-4 4-0-4 7-0-0 11-4-0 15-8-0 20-0-0 24-4-0 28-8-0 33-0-0 35-3.1-12 40-0-0 1 13 14 15 16 17 18 19 20 21 12 40-0-0 Plates -- Simpson Strong -Tie 20 ga (AS20) or 18 ga (AS18HS, AS18S5, or AS18S6) indicated by '-18' Code/Design: FBC-2017/TPI-2014 -----------Snow Load Specs----------- --I -----Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Our Factors ASCE7-10 Ground Snow(Pg) = N/A AS E7-10 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered B1 g Dims: L = 0.0 ft B = 0.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Pit 1.25 1.60 N/A Thermal Condition: All Others M.I.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 2 Unobstructed Slippery Roof: No Partially Enclosed - 2000 lb TC Safe Load: No Repetitive Member Increase: No Low -Slope Minimums(Pfmin): No Wiid DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No We Service: No Unbalanced Snow Loads: No EnQQQ Vertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wihd Uplift Reporting: HybridMW OH Soffit Load: 2.0 PSF Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2 --------------Reaction Summary(Lbs)--------------- TrussSpan Limit Actual(in) Location 2x6 SP (ALSC6-2013) #2 3-7 Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/935(-0.50) 17-18 7-10 1 04-00 3580 2728 08-00 02-13 SPF 425 Vert CR L/240 L/455(-1.02) 17-18 BC 2x6 SP (ALSC6-2013) #1 12 39-08-00 3579 2721 08-00 02-13 SPF 425 Webs 2x4 SP (ALSC6-2013) #2 Max Horiz = -128 / +102 at Joint 1 Horz LL 0.75in ( 0.10) @Jtl2 • Horz CR 1.25in ( 0.21) @Jtl2 Member Forces Summary Loads Summary ..Mem... Ten Comp .CSI. This truss has been designed for the eff cts of an unbalanced top chord •' TC OH- 1 53 0 0.33 live load occurring at [200000] using a 00 Full and 0.00 Reduced load 1- 2 6649 7547 0.77 factor. Vert CR and Horz CR are the vertical and 2- 3 7152 7961 0.77 horizontal deflections due to live load 3- 4 9713 10729 0.77 See Loadcase Report for loading combinat ons and additional details. plus the creep component of deflection 4- 5 11544 12802 0.92 Dead Loads may be slope adjusted: > 12.012 due to dead load, computed as Defl LL + 5- 6 12156 13488 0.91 Concentrated Loads - Based on Live Load (Kcr - 1) x Defl_DL in accordance with 6- 7 12157 13489 0.90 Domain Load Uplift Location Dir ascription ANSI/TPI 1. 7- 8 12157 13489 0.89 Transfer loads: 8- 9 11542 12794 0.92 TC 170 -239 7-00-12 Vert 17 @ 90 Deg 9-10 9722 10728 0.77 TC 80 -97 7-01-08 Vert 3 @ 135 Deg 117 Bracing Data Summary 10-11 7148 7960 0.77 TC 170 -239 9-00-12 Vert 17 @ 90 Deg ------------Bracing Data------------ 11-12 6647 7544 0.77 TC 170 -239 11-00-12 Vert 17 @ 90 Deg Chords; continuous except where shown 12-OH 53 0 0.33 TC 170 -239 13-00-12 Vert 17 @ 90 Deg Web Bracing -- None BC 1-13 6907 5861 0.65 TC 170 -239 15-00-12 Vert @ 90 Deg L 2 21 6905 5875 0.65 TC 170 -239 17-00-12 Vert J17 @ 90 Deg' eg Plate offsets ( 13-14 6907 5861 0.65 TC 170 -239 18-11-04 Vert 417 @ 90 Deg i di (None unless indicated below) 14-15 7316 6248 0.50 TC 170 -239 20-11-04 Vert J17 @ 90 Deg Jntl(00-06,00-03), Jnt3(00-03,-00-06), 15-16 10731 9320 0.72 TC 170 -239 22-11-04 Vert J17 @ 90 De g Jnt10 (-00-03,-00-06), 16-17 12860 11213 0.83 TC 170 -239 24-11-04 Vert J17 @ 90 Deg Jntl2(-00-06,00-03), Jntl5(-00-08,0), 17-18 12852 11211 0.83 TC 170 -239 26-11-04 Vert J17 @ 90 Deg Jnt16(0,-02-00), Jnt18 (0,-02-00), id-19 10726 9325 0.72 TC 170 -239 28-11-09 Vert 17 @ 90 De � 9 Jnt19(00-08,0) 19-20 7315 6262 0.50 TC 170 -239 30-11-04 Vert J17 @ 90 Deg 20-21 6904 5875 0.65 TC 80 -97 32-10-08 Vert J3 @ 45 Deg 170. 32-11-04 J17 Web 2-13 565 2-14 482 494 0.05 543 0.05 TC -239 Vert @ 90 Deg BC 70 0 7-00-12 Vert J17 @ 90 Deg ��� L. G /V / \ \ 3-19 293 0.4 92 BC -98 7-01-OB Vert } J3 @ 135 Deg ,,...,• \ ••'.•� /� 3-15 3966 4-15 1963 3567 567 0.44 1876 0.17 BC 70 0 9-00-12 Vert 17 @ 90 Deg BC 70 0 11-00-12 Vert 17 @ 90 Deg �/�•••\�\C'ENSF �•'• ••� 4-16 2490 2199 0.28 BC 70 0 13-00-12 Vert 417 @ 90 Deg •'•: 5-16 1245 1107 0.11 BC 70 0 15-00-12 Vert J17 @ 90 Deg BC 70 0 17-00-12 Vert @ 90 Deg _ * NO. 76864 5-17 1261 6-17 799 651 0.14 591 0.07 f7 BC 70 0 18-11-04 Vert 17 @ 90 Deg _ 8-17 1268 655 0.14 BC 70 0 20-11-04 Vert 417 @ 90 Deg 8-18 1239 1107 0.11 BC 70 0 22-11-04 Vert J17 @ 90 Deg 9-18 2486 2190 0.28 BC 70 0 24-11-04 Vert J17 @ 90 Deg 9-19 1961 1877 0.17 BC 70 0 26-11-04 Vert J17 @ 90 Deg i 10-19 3966 3561 0.44 BC 70 0 28-11-04 Vert J17 @ 90 Deg 10-20 293 112 0.04 BC 70 0 30-11-04 Vert @ 90 Deg �O�•% �/ •••• �• 11-20 484 545 0.05 BC 92 -98 32-10-08 Vert 3 @ 45 Deg BC 70 0 32-11-04 Vert 17 @ 90 Deg G\ \\\ //// S/0���•G� 11-21 565 496 0.05 117 \\\ / / / / \5/223/2018 I I I I t CO A #30009 NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by lh Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Des. i gner. P seal on this drawing indicates acceptance of Component Solutions ® professional engineering responsibility solely for the truss component design shown. See the cover page and the'Important Information & General Notes ° page for Truss Studio V additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge 2018.1.0. 87 2018.1. 0. unless the specified plate size is followed by a'-18° which indicates an 18 gauge plate, or'S# 18°, which indicates a high tension 18 gauge plate. r r 1-866-252-9606 • CSBelpsk: gtie, com Project Name: 00280- Hancock Residence - Tree Top Trail Qty: 1 Truss: A7A Customer: Gillespie Builders SID: 0000258545 TID: 66489 Date: 05 / 24 / 18 Truss Mfr. Contact: Rick Mills Page: 2 of 2 2-PLY TRUSS Fastener Spacing Fasten each ply to the adjacent ply as follows(rows staggered): TC, 1-row(s) of 10d Nails (0..120" dia. x 2-7/6" min.) @ 12.011 o.c. BC, 2-row(s) of 10d Nails (0.120" dia. -x 2-7/8" min.) @ 12.011 o.c. WB, 1-rows) of 10d Nails (0.120" dia. x 2-7/8" min.) @ 9.0" o.c. Plates designed for Cq at 0.80 and Rotational Tolerance of 10-0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Less than 0.25/12 pitch requires adequate drainage to prevent ponding. * : No. 76864 -0 c Q� •• ST E COA #30003 5/23/2018 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on pesign criteria and requirements supplied by th Component Solutions Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. seal on this drawing indicates acceptance of Truss Studio V professional engineering. responsibility solely for the truss component design shown. See the cover page and the 'Import nt Information & General Notes page for Truss . 0. additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge . 2018.1.0 .87 unless the specked plate size is followed by a "-18• which indicates an 18 gauge plate, or "S# 18. which indicates a high tension 18 gauge plate. ® Helpdesk: -252-8606 CSHelp@strongtie.com 1-8666 corn Project Name: 00280- Hancock Residence - Tree Top Trail Qty: 1 Truss: B1 Customer: Gillespie Builders SID: 0000258546 TID: 66489 Date: 05 / 24 / 18 Truss Mfr. Contact: Rick Mills Page: 1 of 1 2-Ply 3-1-0 1 3-0-0 3-0-0 _ 3-1-0 6-1-0 9-1-0 1 2 3 4 -62# 5/12 45# 45# 45# 3x8 2x31) 3x10 O0 4x6 I 00 4-1 _ r-I '-1 3x6 7x12 3x6 8" 4 16 4 - 1752# 16# 16# 16# -60# 1454# 1454# 1752# 3-1-0 370-0 3-0-0 3-1-0 6 1-0 9-1-0 1 5 6 7 91-0 Plates -- Simpson Strong -Tie 20 ga (AS20) or 18 ga (AS18HS, AS18S5, or AS18S6) ind' ated by '-18' Code/Design: FBC-2017/TPI-2014 -----------Snow Load Specs----------- -- Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead our Factors ASCE7-10 Ground Snow(Pg) = N/A AS E7-10 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC' 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Rilk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 0.0 ft B - 0.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others M.E.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 2 Unobstructed Slippery Roof: No Partially Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: No Green Lumber: No Wet Service: No Low -Slope Minimums(Pfmin): No Unbalanced Snow Loads: No Wind En DL(psf): TC = 5.0 BC = 5.0 Vertical Exposed: L = Yes R = Yes Unbalanced TCLL: Yes Fab Tolerance: 20% Creep (Kcr) - 2.0 Rain Surcharge: No Ice Dam Chic: No Wind Uplift Reporting: HybridMW OR Soffit Load: 2.0 PSF Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2--------------Reaction Summary(Lbs) --------------- TrussSpan Limit Actual(in) Location BC 2x6 SP (ALSC6-2013) #1 Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999(-0.05) 5- 6 Webs 2x4 SP (ALSC6-2013) #2 1 04-00 3945 1664 08-00 03-02 SPF 425 Vert CR L/240 L/820(-0.12) 5- 6 7 8-11-04 3184 1620 03-00 HGR SPF 565 Member Forces Summary Max Horiz = -16 / +75 at Joint 1 Horz LL 0.75in ( 0.01) @Jt 1 ..Mem... Ten Comp .CSI. Horz CR 1.25in ( 0.02) @Jt 1 TC 1- 2 3157 6485 0.37 Loads Summary 2- 3 3053 5573 0.39 This truss has been designed for the effe is of an unbalanced top chord 3- 4 3054 5574 0.43 _ live load occurring at [407001 using a 1.10 Full and 0.00 Reduced load 9-OH 0 0 0. factor. Vert CR and Horz CR are the vertical and BC 1- 5 5979 2892 0.63 horizontal deflections due to live load 5- 6 5821 2838 0.75 See Loadcase Report for loading combinations and additional details. plus the creep component of deflection 6- 7 34 32 0.37 Dead Loads may be slope adjusted: > 12.0/ 2 due to dead load, computed as Defl LL + 7-OH 0 0 0.00 Concentrated Loads - Based on Live Load (Kcr - 1) x Defl_DL in accordance with Web 2- 5 2298 781 0.26 Domain Load Uplift Location Dir Description ANSI/TPI 1. 2- 6 403 933 0.05 Transfer loads: 3- 6 408 96 0.03 TC 45 -70 3-01-12 Vert J13 @ -90 Deg 4- 6 6086 3293 0.68 TC -62 0 3-02-08 Vert J�B @ -135 Deg Bracing Data Summary 4- 7 1523 2598 0.13 TC 45 -70 5-01-12 Vert J13 @ -90 Deg ------------Bracing Data ------------ TC 45 -70 7-01-12 Vert J13 @ -90 Deg Chords; continuous except where shown BC 1752 -591 1-03-04 Vert A#A @ 90 Deg Web BC 16 0 3-01-12 Vert J 3 @ -90 Deg Bracing -- None BC -60 0 3-02-08 Vert J�B @ -135 Deg Plate offsets (X,l): J BC 1752 -591 3-03-09 Vert )A @ 90 Deg (None BC 16 0 5-01-12 Vert I3 @ -90 Deg unless indicated below) Jnt4(-01-08,0), BC 1454 -733 5-03-04 Vert A2A @ 90 Deg JntS(0,-01-09), BC 16 0 7-01-12 Vert J13 @ -90 Deg Jnt6(0,-00-10), Jnt7(0,-01-01) BC 1454 -733 7-03-04 Vert A1A @ 90 Deg 2-PLY TRUSS Fastener Spacing Fasten each ply to the adjacent ply as fo lows(rows staggered): TC, 1-row(s) of 10d Nails (0-120" dia. x ? 7/8" min.) @ 12.0" o-c. BC, 2-row(s) of lOd Nails (0.120" dia. x 7t-7/8" min.) @ 12.0" o.c.** • WE, 1-row(s) of 10d Nails (0.120" dia. x �-7/8" min.) @ 9.0" o_c. ** Use additional fasteners of the same tyYppe within +/-12" of the '••\\BEN SF ••� ••• •••� locations) indicated (except where approded hangers are used with �: fasteners that transfer the load to all plies): No. 76864 = * *, _ BC:1-03-04, 7, BC:3-02-08, 7, BC:5-02-0J, 5 BC:7-02-08, 5 - - i Notes ST E Plates designed for Cq at 0.80 and Rotatio al Tolerance of 10.0 • • degrees •• •.'• / \� Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. �� // (1 " " • !� \� Less than 0.25/12 pitch requires adequate r1ainage to prevent ponding. t5/23/2018 COA #30003 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on dJslgn criteria and requirements supplied by lh Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of Component Solutions professional engineering responsibility solely for the truss component design shown. See the cover page and the 'Important Information & General Notes" page for Truss Studio V St additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge 201E E7 2018.1. 0. unless the specified plate size is followed by a "-18" which indicates an 16 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. r 1-866-252-8606 • CSHelp@strongtie.com corn Project Name: 00280 - Hancock Residence - Tree Top Trail I Qty. 27 Truss: J17 Customer: Gillespie Builders SID: 0000258547 TID: 66489 Date: 05 / 23 / 18 Truss Mfr. Contact: Rick Mills Page: 1 of 1 2-0-0 7-1,0-0 7-'0-0 1 2 5/1 M I • M 3x4= I "1 0 4-1 - 8" 7-0-0 7-0-0 3 Plates -- Simpson Strong -Tie 20 ga (AS20) or 18 ga (AS18HS, S18S5, or AS18S6) indi ated by '-18' Code/Design: FBC-2017/TPI-2014 -----------Snow Load Specs----------- --- ------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead our Factors ASCE7-10 Ground Snow(Pg) = N/A ASC 7-10 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Ris Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bid Dims: L = 0.0 ft B = 0.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Pit 1.25 1.60 N/A Thermal Condition: All Others M.R H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bld6 Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Win DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No EndlVertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: HybridMW OH Soffit Load: 2.0 PSF Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2--------------Reaction Summary(Lbs) --- --- --------- TrussSpan Limit Actual(in) Location BC 2x4 SP (ALSC6-2013) #2 Jot--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/834(-0.09) 1- 3 1 03-14 446 341 08-00 00-11 SPF 425 Vert CR L/240 L/387(-0.19) 1- 3 Member Forces Summary 3 7-00-00 121 0 01-08 00-02 SPF 565 ..Mem... Ten Comp .CSI. 2 7-00-00 170 238 01-08 00-03 SPF 565 Horz LL 0.75in ( 0.03) @Jt 1 �1C OH- 1 51 0 0.56 Max Horiz = +0 / +300 at Joint 1 Horz CR 1-25in ( 0.05) @Jt 1 1- 2 65 162 0.96 BC 1- 3 0 0 0.48 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [70000] using a 1. 0 Full and 0.00 Reduced load Vert CR and Horz CR are the vertical and ` factor. horizontal deflections due to live load. plus the creep component of deflection See Loadcase Report for loading combinations and additional details. due to dead load, computed as Defl LL + Dead Loads may be slope adjusted: > 12.0/ 2 (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 Bracing Data Summary degrees ------------Bracing Data ------------ Plates located at TC pitch breaks meet the prescriptive minimum size Chords; continuous except where shown requirement to transfer unblocked diaphragm loads across those joints. Web Bracing -- None ` Plate offsets (X, Y): (None unless indicated below) Jntl(ol-09,00-10) v \�11111111///// �.��� ��( �•. GUN �'% �,ICENSk- No. 76864 � Q� • ST E �� / / / I I I I ► 15/23/2018 COA #30003 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by th Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A Component Solutions peal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the •Important Trusa Studio V InfonnaU 8 General Notes' page for t. additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with 2018.1 87 SR-2762. All connector plates are 20 gauge unless the specked plate size is followed by a •-18' which indicates an 18 gauge plate, or •S# 18", which indicates a high to r Helpdesk: 1-e66-252-8606 Sion 18 gauge plate. 1-866 252 m CSHelpsk: Project Name: 00280 - Hancock Residence - Tree Top Trail Qty: 3 Truss: J13 Customer: Gillespie Builders SID: 000025B548 TID: 66489 Date: 05 / 23 / 18 Truss Mfr. Contact: Rick Mills Page: 1 of 1 2-0-0 3;1-0 3-1-0 1 2 5/ 2 00 00 3x � 4-1 ,I M I � N 811 3;1-0 3! 1-0 Plates -- Simpson Strong -Tie 20 ga (AS20) or 18 ga (AS18HS, AS18S5, or A 18S6) indicated by 1-18, Code/Design: FBC-2017/TPI-2014 -----------Snow Load Specs----------- -- --Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-10 Ground Snow(Pg) = N/A ASCE7-10 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risllk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 0.0 ft B = 0.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Pit 1.25 1.60 N/A Thermal Condition: All Others M. .H(h) - 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No En Vertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Win Uplift Reporting: HybridMW OH Soffit Load: 2.0 PSF Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2--------------Reaction Summary(Lbs) ------ --------- TrussSpan Limit Actual(in) Location BC 2x4 SP (ALSC6-2013) #2 Jut--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999( 0.00) 1- 3 1 03-14 327 290 08-00 00-06 SPF 425 Vert CR L/240 L/999( 0.00) 1- 3 Member Forces Summary 3 3-01-00 39 0 01-08 00-01 SPF 565 ..Mem... Ten Comp .CSI. 2 3-01-00 45 70 01-08 00-01 SPF 565 Horz LL 0.75in ( 0.09) @Jt 1 OH- 1 51 0 0.56 Max Horiz = +0 / +165 at Joint 1 Horz CR 1.25in ( 0.11) @it 1 1- 2 17 40 0.27 BC 1- 3 0 0 0.20 Loads Summary This truss has been designed for the effe is of an unbalanced top chord live load occurring at [30100] using a 1.)0 Full and 0.00 Reduced load Vert CR and Horz CR are the vertical and • factor. horizontal deflections due to live load plus the creep component of deflection See Loadcase Report for loading combinati ns and additional details. due to dead load, computed as Defl LL + Dead Loads may be slope adjusted: > 12.0/ 2 (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. Notes Plates designed for Cq at 0.80 and Rotati nal Tolerance of 10.0 Bracing Data Summary degrees ------------Bracing Data ------------ Plates located at TC pitch breaks meet th prescriptive minimum size Chords; continuous except where shown requirement to transfer unblocked diaphrarm loads across those joints. Web Bracing -- None ' Plate offsets (X, l): (None unless indicated below) • \\��ttt]I]I////// orENSF * No. 76864 0 ST E / A`5/23/2018 / / / / I COA #30003 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by th Component Solutions Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. Alseal on this drawing indicates acceptance of Studio V professional engineering responsibility solely for the truss St ss component design shown. See the cover page and the "Important Information 8 General Notes" page for Truss 2018.1.0.87 additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with IESR-2762. All connector plates are 20 gauge r . Helpdesk:1-861-8666-252 252 -8606 unless the specified plate size is followed by a "-18' which indicates an 18 gauge plate, or "S# 18•. which indicates a high tgnsion 18 gauge plate. • Project Name: 00280 - Hancock Residence - Tree Top Trail Qty 8 Truss: J25 Customer: Gillespie Builders SID: 0000258549 TID: 66489 Date: 05 / 23 / 18 Truss Mfr. Contact: Rick Mills Page: 1 of 1 2-0-0 4-11-11 F� 4- 1-11 1 2 5/1 Ln Ln 3x�k 4-1 N N I M 81' 4-1 -11 4-1 -11 1 3 Plates -- Simpson Strong -Tie 20 ga (AS20) or 18 ga (AS18HS, AS18S5, or A918S6) indil ated by '-18' Code/Design: FBC-2017/TPI-2014 -----------Snow Load Specs ----------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-10 Ground Snow(Pg) = N/A ASC 7-10 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Ris Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered BldgDims: L = 0.0 ft B = 0.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others M.RH(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Win DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L - Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Win Uplift Reporting: HybridMW OR Soffit Load: 2.0 PSF Material Summary Reaction Summary I Deflection Summary m TC 2x4 SP (ALSC6-2013) $2--------------Reaction Sumary(Lbs)------ --------- TrussSpan Limit Actual(in) Location BC 2x4 SP (ALSC6-2013) #2 Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999(-0.02) 1- 3 1 03-14 377 306 08-00 00-09 SPF 425 Vert CR L/240 L/999(-0.04) 1- 3 Member Forces Summary 3 4-11-11 80 0 01-12 00-02 SPF 565 ..Mem... Ten Comp .CSI. 2 4-11-11 109 156 01-12 00-02 SPF 565 Horz LL 0.75in ( 0.08) Vt 1 TC OH- 1 51 0 0.56 Max Horiz = +0 / +230 at Joint 1 Horz CR 1.25in ( 0.09) Vt 1 1- 2 42 105 0.44 BC 1- 3 0 0 0.20 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at (411111 using a l.(}0 Vert CR and Horz CR are the vertical and Full and 0.00 Reduced load ' factor. horizontal deflections due to live load plus the creep component of deflection See Loadcase Report for loading combinations ql and additional details. due to dead load, computed as Defl LL + Dead Loads may be slope adjusted: > 12.0/2 (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 Bracing Data Summary degrees ------------Bracing Data ------------ Plates located at TC pitch breaks meet thE prescriptive minimum size Chords; continuous except where shown requirement to transfer unblocked diaphracm loads across those joints. Web Bracing -- None Plate offsets (X, l): (None unless indicated below) Y %�,p�i �(��•'•L�GENSF' * No, 76864 . Q ST E O! '*,Z, . A ON� ��. `E COA #30003 5/23/2018 NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by lh Component Solutions Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A on this drawing indicates peal acceptance of Truss S tudio V professional engineering responsibility solely for the truss component design shown. See the cover page and the 'Important Information 8 General Notes" page for Truss . 0.87 2018.1.0. additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge r r 1-866 252 unless the specked plate size is followed by a "-18' which indicates an 18 gauge plate, or •S# 18", which indicates a high tension 18 gauge plate. Helpdesk:1-866-252-8606 Project Name: 00280 - Hancock Residence - Tree Top Trail Qty: 8 Truss: J23 Customer: Gillespie Builders SID: 0000258550 TID: 66489 Date: 05 / 23 / 18 Truss Mfr. Contact: Rick Mills Page: 1 of 1 2-0-0 2-11-11 2- 11-11 1 2 366# 5/1 Ln In 3xl= A r I H 6 4-1 e I I ) N 8 r, 2-11-11 2-1I1-11 ' -� Plates -- Simpson Strong -Tie 20 ga (AS20) or 18 ga (AS18HS, AS18S5, or AS18S6) indicated by '-18' Code/Design: FBC-2017/TPI-2014 -----------Snow Load Specs----------- ---- -----Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-10 Ground Snow(Pg) = N/A ASCE -10 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 0.0 ft B = 0.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others M.R. (h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: No Low -Slope Minimums(Pfmin): No Wind DL (psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End lertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: HybridMW OR Soffit Load: 2.0 PSF Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2--------------Reaction Summary(Lbs)------- -------- TrussSpan Limit Actual(in) Location BC 2x4 SP (ALSC6-2013) #2 Jnt--X-Loc- React -Up- --Width- -Regd Mat PSI Vert LL L/360 L/999( 0.01) 1- 3 1 03-14 392 341 08-00 00-10 SPF 425 Vert CR L/240 L/999( 0.01) 1- 3 Member Forces Summary 3 2-11-11 50 16 01-12 00-01 SPF 565 ..Mem... Ten Comp .CSI. 2 2-11-11 25 53 01-12 0 SPF 565 Horz LL 0.75in ( 0.11) @Jt 1 TC OH- 1 65 10 0.77 Max Horiz = +0 / +162 at Joint 1 Horz CR 1.25in ( 0.13) @Jt 1 1- 2 18 45 0.36 I BC 1- 3 0 0 0.28 Loads Summary This truss has been designed for the effect of an unbalanced top chord live load occurring at [211111 using a 1.00 Full and 0.00 Reduced load Vert CR and Horz CR are the vertical and • factor. horizontal deflections due to live load plus the creep component of deflection See Loadcase Report for loading combination and additional details. due to dead load, computed as De£1_LL + Dead Loads may be slope adjusted: > 12.0/12 (Kcr - 1) x Defl_DL in accordance with Concentrated Loads - Based on Live Load ANSI/TPI 1. Domain Load Uplift Location Dir Des ription User loads: TC 36 -27-1-11-00 Vert Use -Defined @ 90 Deg Bracing Data Summary ------------Bracing Data ------------ Chords; continuous except where shown Notes Web Bracing -- None Plates designed for Cq at 0.80 and Rotation 1 Tolerance of 10.0 • degrees Plate offsets (X, Y): Plates located at TC pitch breaks meet the prescriptive minimum size (None unless indicated below) requirement to transfer unblocked diaphragm loads across those joints. ' \�`ttllllil//// T ocEN&,c * No. 76864 Q� •. ST E \ �•�' �V �ONI I I W coAas0003// /2018 NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on desigh criteria and requirements supplied by th Component solutions Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. Aseat on this drawing indicates acceptance of Truss Studio V professional engineering responsibility solely for the truss component design shown. Seethe cover page and the "Important Inf'onnation & General Notes' page for Truss 2018.1.0.87 additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge unless the specified plate size is followed by a'-18• which indicates an 18 gauge plate, or •S# 18', which indicates a high tension 18 gauge plate. Helpdask:1-861-8666-252 252 -8606 11= ® ( ) N Project Name: 00280 - Hancock Residence - Tree Top Trail I Qty. 10 Truss: J21 Customer: Gillespie Builders SID: 0000258551 TID: 66489 Date: 05 / 23 / 18 Truss Mfr. Contact: Rick Mills Page: 1 of 1 2-0-0 1 2 5/ 2 8-15 4-1 3I rl z ,I I 2-12 2-01-10-0 llr 11 �ed Plates -- Simpson Strong -Tie 20 ga (AS20) or 18 ga (AS18HS, AS18S5, or AS18S6) id Gaby '-18' Code/Design: FBC-2017/TPI-2014 PSF Live Dead our Factors -----------Snow Load Specs----------- ASCE7-10 Ground Snow(Pg) = N/A ----- L ---- Wind Load Specs ---------- ASCE7Li10 Wind Speed(V) = 170 -------Additional Design Checks------ 10 TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C mph Risk Cat: II Exposure Cat: C psf Non -Concurrent BCLL: Yes 20 psf SC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg bims: L = 0.0 ft B = 0.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others M.R.Hih) = 15.0 £t Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg 4nclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vortical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind [�plift Reporting: HybridMW OR Soffit Load: 2.0 PSF Material Summary Reaction Summary Deflection Summary TC 2x9 SP (ALSC6-2013) #2--------------Reaction Summary(Lbs)--------- ------ TrussSpan Limit Actual(in) Location BC 2x4 SP (ALSC6-2013) @2 Jnt--X-Loc- React -Up- --Width- -Regd -M t PSI Vert LL L/360 L/999( 0.00) 1- 3 1-1-09-00 204 189 01-08 00-01 S F 565 Vert CR L/240 L/999( 0.00) 1- 3 Member Forces Summary 1 02-12 204 189 05-08 00-03 StF 453 . .Mem... Ten Comp .CSI. 3 11-11 8 3 01-12 0 S F 565 Horz LL 0.75in ( 0.00) @Jt 1 bHL 1- 1 66 29 0.10 2 11-11 4 12 01-12 0 S>F 565 Horz CR 1.25in ( 0.00) @it 1 TC OH- 1 6 0 0.00 Max Horiz = +0 / +93 at Joint 1 1- 2 3 7 0.00 BC 1- 3 0 0 0.00 Loads Summary This truss has been designed for the effects of an unbalanced top chord Vert CR and Horz CR are the vertical and • live load occurring at [1111] using a 1.00 11 and 0.00 Reduced load horizontal deflections due to live load factor. plus the creep component of deflection due to dead load, computed as Defl LL + See Loadcase Report for loading combinations and additional details. (Kcr - 1) x Defl_DL in accordance with Dead Loads may be slope adjusted: > 12.0/12 ANSI/TPI 1. Notes Bracing Data Summary Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0------------Bracing Data ------------ degrees Chords; continuous except where shown Plates located at TC pitch breaks meet the pr scriptive minimum size Web Bracing -- None requirement to transfer unblocked diaphragm l ads across those joints. Plate offsets (X, l): (None unless indicated below) \0\111111//// �`! �•. GUN /'�� �•��� ' T� &q OCENSF'. i * No. 76864 Q ST E III \5/23/2018 COA #30003 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by th Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on }his drawing indicates acceptance of Component Solutions professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General Notes" page for Truss Studio V additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge 2012018.1.0.87 unless the specified plate size Is followed by a'-18' which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. f'desk: 1-866-252-8606 ® CSHelp@strongtie.com -4 [ r ot Project Name: 00280 - Hancock Residence - Tree Top Trail I Qty: 4 Truss: J3 Customer: Gillespie Builders SID: 0000258552 TID: 66489 Date: 05 / 23 / 18 Truss Mfr. Contact: Rick Mills Page: 1 of 1 2-9-15 5-4-4 4-5-13 5-4-4 9-10-1 1 12 3 5# 25# 110# 4�# 5�# 21# 11�0# 3.54/12 3x4 vrNIi II I 3x4= CI 4-1 1= 2x32x3- 10.9375" " -3# -16# -3# -16# 40# 40# 5-4-4 ) 4-5-13 5-4-4 9-10-1 1 4 5 1 il 9-19-1 Plates -- Simpson Strong -Tie 20 ga (AS20) or 18 ga (AS18HS, AS18S5, or AS18S6) indicat'led by '-18' Code/Design: FBC-2017/TPI-2014 -----------Snow Load Specs ----------- ------ ---Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-10 Ground Snow(Pg) = N/A ASCE7-�0 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk C t: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 0.0 ft B = 0.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others M.R.H(�) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 0 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: No Low -Slope Minimums(Pfmin): No Wind A (psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L - Yes R Yes Fab Tolerance: 20% Creep (Kcr) - 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: HybridMW OR Soffit Load: 2.0 PSF Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) 41--------------Reaction Summary(Lbs)---------- ----- TrussSpan Limit Actual(in) Location BC 2x4 SP (ALSC6-2013) #2 Jnt--X-Loc- React -Up- --Width- -Regd -Ma PSI Vert LL L/360 L/999(-0.03) 4- 5 Webs 2x4 SP (ALSC6-2013) A2 1 05-04 368 310 10-15 00-09 SP€ 425 Vert CR L/240 L/999(-0.06) 4- 5 5 9-08-09 91 98 01-12 00-02 SP F 565 Member Forces Summary 3 9-10-01 79 96 01-12 00-02 SP 565 Horz LL 0.75in ( 0.14) @Jt 1 . ..Mem... Ten Comp .CSI. Max Horiz +0 / +0 at Joint 1 Horz CR 1.251n ( 0.20) @Jt 1 TC OH- 1 64 42 0.79 1- 2 266 155 0.37 Loads Summary 2- 3 61 39 0.43 This truss has been designed for the effects of an unbalanced top chord BC 1- 4 142 239 0.64 live load occurring at [910011 using a 1.00 Fµll1 and 0.00 Reduced load Vert CR and Horz CR are the vertical and 4- 5 142 239 0.37 factor. horizontal deflections due to live load 5-OH 0 0 0.00 I plus the creep component of deflection Web 2- 4 132 51 0.02 See Loadcase Report for loading combinations and additional details. due to dead load, computed as Defl LL + 2- 5 255 151 0.05 Dead Loads may be slope adjusted: > 12.0/12 (Kcr - 1) x Defl_DL in accordance with Concentrated Loads - Based on Live Load ANSI/TPI 1. I Domain Load Uplift Location Dir Descri tion User loads: TC 48 -32-2-09-00 Vert User-D fined @ 90 Deg Bracing Data Summary Transfer loads: ------------Bracing Data ------------ 5 5 -13 1-05-05 Vert J21 @ ]135 Deg Chords; continuous except where shown TC 5 -13 1-05-05 Vert J21 @ 135 Deg Web Bracing -- None 1135 TC 25 -54 4-03-04 Vert J23 @ Deg • TC 25 -54 4-03-04 Vert J23 @ 135 Deg Plate offsets (X,1): TC 110 -157 7-01-03 Vert J25 @ 1 5 Deg TC 110 -157 7-01-03 Vert J25 @ 35 Deg (None unless indicated below) BC -3 0 1-05-05 Vert J21 @ 135 Deg BC -3 0 1-05-05 Vert J21 @ -135 Deg BC -16 0 4-03-04 Vert J23 @ 135 Deg • BC -16 0 4-03-04 Vert J23 @ -135 Deg BC 40 0 7-01-03 Vert J25 @ 135 Deg BC 40 0 7-01-03 Vert J25 @ -135 Deg User Distributed Loads (plf) \\\\\tiiliil///// Domain Load Uplift Start Load Uplift End Dir Description \ \\ ' TC 60.0 -39-2-09-15 60.0 -39 0 Vert User -Defined \ \ �� Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees _ * : No. 76864 '•: *, _. Plates located at TC pitch breaks meet the prescliptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Q ST E / / I AL5/23/2018 COA#300o3 NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design cdtena and requirements supplied by th Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. Aseal on this drawing indicates Component Solutions acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the 'Important Information & General Notes' page for Truss Studio V additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-27621AII connector plates are 20 gauge 2018.1.0.87 2018.1.0. unless the specified plate size Is followed by a ' 18' which indicates an 18 gauge plate, or'S# 18°, which indicates a high tension 18 gauge plate. r 1-8666-252 252 CSHelp@strongtie.com c 1 ) Project Name: 00280 - Hancock Residence - Tree Top Trail Qty.. 1 Truss: 13B Customer: Gillespie Builders SID: 0000258553 TID: 66489 Date: 05 / 23 / 18 Truss Mir. Contact: Rick Mills Page: 1 of 1 2-9-15 14-3-9 ;4-3-9 1 2 5# 4�8# 51 3.54/12 3x� 4-1 N 10.9375" -3 -3 i 4-3-9 3-9 3 Plates -- Simpson Strong -Tie 20 ga (AS20) or 18 ga (AS18HS, AS18S5, or AS18S6) indicted by '-18, Code/Design: FBC-2017/TPI-2014 -----------Snow Load Specs ----------- ---- -----Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead our Factors ASCE7-10 Ground Snow(Pg) = N/A ASCE -10 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 0.0 ft B = 0.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others M.R. (h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 0 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: No Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End ertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) - 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: HybridMW ORSoffit Load: 2.0 PSF Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) @1--------------Reaction Summary(Lbs)---------------- TrussSpan Limit Actual(in) Location BC 2x4 SP (ALSC6-2013) #2 Jot--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999( 0.04) 1- 3 1 05-04 342 306 10-15 00-09 SPF 425 Vert CR L/240 L/732( 0.05) 1- 3 Member Forces Summary 3 4-03-09 48 59 01-12 00-01 SPF 565 . .Mem... Ten Comp .CSI. 2 4-03-09 48 61 01-12 00-01 SPF 565 Horz LL 0.75in ( 0.13) @Jt 1 fiC OH- 1 64 54 0.79 Max Horiz = +0 / +0 at Joint 1 Horz CR 1.25in ( 0.19) @it 1 1- 2 21 20 0.35 BC 1- 3 0 0 0.44 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [403091 using a 1.00 Full and 0.00 Reduced load Vert CR and Horz CR are the vertical and • factor. horizontal deflections due to live load plus the creep component of deflection See Loadcase Report for loading combinations and additional details. due to dead load, computed as Defl LL + Dead Loads may be slope adjusted: > 12.0/12 (Kcr - 1) x Defl_DL in accordance with Concentrated Loads - Based on Live Load ANSI/TPI 1. Domain Load Uplift Location Dir Description " User loads: TC 48 -41-2-09-00 Vert Use. -Defined @ 90 Deg Bracing Data Summary Transfer loads: TC 5 -13 1-05-05 Vert J21 ------------Bracing Data ------------ @ -135 Deg TC 5 -13 1-05-05 Vert J21 Chords; continuous except where shown @ 135 Deg BC -3 0 1-05-05 Vert J21 Web Bracing -- None @ -135 Deg BC -3 0 1-05-05 Vert J21 User Distributed @ 135 Deg t ff Plate offsets Pla (X,Y)= Loads (plf) Domain Load Uplift Start Load Uplift End Dir Description (None unless indicated below) TC 60.0 -51-2-09-15 60.0 -51 0 Vert User -Defined Notes Plates designed for Cq at 0.80 and Rotation 1 Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the requirement to transfer unblocked diaphragm rescriptive minimum size \\�� �� L, G loads across those joints. \\ .•••••• . * No, 76864 t5/23/2018 COA 4300o3 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by th Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of � Component Solutions professional engineering responsibility solely for the truss component design shown. Seethe cover page and the "Important Information Truss Studio V & General Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. 2018.1.0.87 All connector plates are 20 gauge 2018 . . unless the specified plate size is followed by a "48" which indicates an 18 gauge plate, or "Sq 18", which indicates a high tension s0 18 gauge plate. 1-866-252-8606 CsHelp@strongtie.com I l 0 A Project Name: 00280 - Hancock Residence - Tree Top Trail I Qty: 1 Truss: V1 Customer: Gillespie Builders SID: 0000258554 TID: 66489 Date: 05 / 23 / 18 Truss Mfr. Contact: Rick Mills Page: 1 of 1 1�,�0 3-2-8 4-0-0 FF 3-2-8 7--8 1 2 3 5/12 3x4% 2x3ii 3x4% C° 1° I I M M I I I PU 84.875" 2x31( 2x3i 3-2-8 4-0-r0 1 1- 0 3-2-8 7-2 '8 1 4 5� 6 7-0-14 Plates -- Simpson Strong -Tie 20 ga (AS20) or 18 ga (AS18HS, AS18S5, or AS18S6) indicated by ' 18' Code/Design: £BC-2017/TPI-2014 PSF Live Dead Dur Factors -----------Snow Load Specs----------- ASCE7-10 Ground Snow(Pg) = N/A ----- i ---- Wind Load Specs ---------- ASCE7110 Wind Speed(V) -------Additional Design Checks------ TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C = 170 mph Risk fat: II Exposure Cat: C 10 psf Non -Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes BC 0.0 1.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 0.0 ft B = 0.0 ft 200 lb BC Accessible Ceiling: No Total 31.0 Plt 1.25 1.60 N/A Thermal Condition: All Others M.R.H (h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Ld+nclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind L(psf): TC = 5.0 BC = 1.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End V rtical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind lift Reporting: HybridMW OH Soffit Load: 2.0 PSF Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2--------------Reaction Summary(Lbs)--------- ------ TrussSpan Limit Actual(in) Location BC 2x4 SP (ALSC6-2013) #2 Jnt--X-Loc- React -Up- --Width- -Reed -M t PSI Vert LL L/360 L/999(-0.00) 1- 4 Webs 2x4 SP (ALSC6-2013) #2 4 3-00-12 214 267 7-00-14 Vert CR L/240 L/999(-0.00) 1- 4 Reactions not shown: down < 400 and up < 150 Member Forces Summary ---- Reaction Summary (plf) ----- Horz LL 0.75in ( 0.00) @Jt 1 ..Mem... Ten Comp .CSI. Jnt-Jnt React -Up- --Width- Horz CR 1.25in ( 0.00) @it 1 TC 1- 2 32 48 0.11 1- 6 31 33 7-00-14 (reduced) 2- 3 28 26 0.37 Max Horiz = -13 / +58 at Joint 1 3-OH 0 0 0.00 BC 1- 4 37 30 0.03 Loads Summary Vert CR and Horz CR are the vertical and 4- 5 28 26 0.02 This truss has been designed for the effects of an unbalanced top chord horizontal deflections due to live load 5- 6 28 26 0.01 live load occurring at [402081 using a 1.00 ull and 0.00 Reduced load plus the creep component of deflection 6-OH 0 0 0.00 factor. due to dead load, computed as Defl LL + Web 2- 4 407 203 0.07 (Kcr - 1) x Defl_DL in accordance with 3- 6 230 118 0.05 See Loadcase Report for loading combinations and additional details. ANSI/TPI 1. Dead Loads may be slope adjusted: > 12.0/12 Bracing Data Summary Notes ------------Bracing Data ------------ Valley Truss application only Chords; continuous except where shown Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 Web Bracing -- None degrees Plates located at TC pitch breaks meet the prescriptive minimum size Plate offsets (X, Y): requirement to transfer unblocked diaphragm loads across those joints. (None unless indicated below) Less than 0.25/12 pitch requires adequate drainage to prevent ponding. \\111111�/// \ IS L. GUN''% / •• ocENSF' * No. 76864 Al- COA #30003 5/23/2018 NOTICE A copy of this design shell be furnished to the erection contractor. The design of this individual truss is based on design c�'teria and requirements supplied by th Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal or} this drawing indicates acceptance of engineering responsibility for the truss "Important ® Component Solutions Truss Studio V professional solely component design shown. See the cover page and the Information & General Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge 2018.1.0 . 2018.1.0.87 unless the specified plate size is followed by a "-18" which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 8 gauge plate. r Helpdesk:1-8666-252 252 -8606 m CSHelp@strongtie.com Project Name: 00280 - Hancock Residence - Tree Top Trail I Qty: 9' Truss: V2 Customer: Gillespie Builders SID: 0000258555 TID: 66489 Date: 05 / 23118 Truss Mfr. Contact: Rick Mills Page: 1 of 1 1140 3-2-8 2-0,-0 3-2-8 5- 2 1 2 3 5/12 3x4% 2x3ii 3x4%B `° `o I I r» m I I 60.875" 72x3l2x3i 3-2-8 2-0-, 1- 0 3-2-8 5-2- 1 4 15 J J 5-0-14 Plates -- Simpson Strong -Tie 20 ga (AS20) or 18 ga (AS18HS, AS18S5, or AS18S6) indicated by '-18' Code/Design: FBC-2017/TPI-2014 PSF Live Dead Dur Factors -----------Snow Load Specs----------- ASCE7-10 Ground Snow(Pg) = N/A -- ---- 1--- Wind Load Specs ---------- ASCE7- 0 Wind Speed(V) = 170 mph -------Additional Design Checks------ 10 ps£ Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 1.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 0.0 ft B = 0.0 ft 200 lb BC Accessible Ceiling: No Total 31.0 Plt 1.25 1.60 N/A Thermal Condition: All Others M.R.H(t) = 15.0 ft Kzt - 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg E closure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DI�(psf): TC = 5.0 HC = 1.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vez�tical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Upllift Reporting: HybridMW _� OH Soffit Load: 2.0 PSF Material Summary Reaction Summary I Deflection Summary TC 2x4 SP (ALSC6-2013) #2--------------Reaction Summary(Lbs)---------------- TrussSpan Limit Actual(in) Location BC 2x4 SP (ALSC6-2013) #2 Jnt--X-Loc- React -Up- --Width- -Regd -Mai Psi Vert LL L/360 L/999(-0.00) 1- 4 Webs 2x4 SP (ALSC6-2013) #2 4 3-00-12 140 177 5-00-14 Vert CR L/240 L/999(-0.00) 1- 4 Reactions not shown: down < 400 and up < 150 Member Forces Summary ---- Reaction Summary (plf) ----- Herz LL 0.75in ( 0.00) @Jt 1 ..Mem... Ten Comp .CSI. Jnt-Jnt React -Up- --Width- Horz CR 1.25in ( 0.00) @Jt 1 TC 1- 2 24 38 0.05 1- 5 34 36 5-00-14 (reduced) 2- 3 28 26 0.08 Max Horiz = -13 / +58 at Joint 1 3-OH 0 0 0.00 BC 1- 4 34 28 0.05 Loads Summary Vert CR and Herz CR are the vertical and • 4- 5 28 26 0.02 horizontal This truss has been designed for the effects o an unbalanced top chord deflections due to live load 5-OH 0 0 0.00 live load occurring at [30808] using a 1.00 Fu 1 and 0.00 Reduced load Plus the creep component of deflection Web 2- 4 250 123 0.04 factor. due to dead load, computed as Defl LL + 3- 5 120 62 0.03 (Kcr - 1) x Defl_DL in accordance with See Loadcase Report for loading combinations a d additional details. ANSI/TPI 1.' Dead Loads may be slope adjusted: > 12.0/12 Bracing Data Summary Notes ------------Bracing Data ------------ Valley Truss application only Chords; continuous except where shown Plates designed for Cq at 0.80 and Rotational T lerance of 10.0 Web Bracing -- None degrees Plates located at TC pitch breaks meet the pres riptive minimum size Plate offsets(X, l)• requirement to transfer unblocked diaphragm loa s across those joints. (None unless indicated below) Less than 0.25/12 pitch requires adequate drain ge to prevent ponding. ,qQ��..�'• Q� •. ST E I I I 1 15/23/20 COA #30003 1 8 NOTICE copy this design shall be famished to the erection contractor. The design of this individual truss is based on design tia and requirements supplied by th Truss Mann ufacturerer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal onnthis drawing indicates acceptance Component Solutions of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General Notes' page for Truss Studio V additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762.IAII connector plates are 20 gauge 2018.1.0.87 0. unless the specked plate size is followed by a "-18" which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. r 8elpd1. 1-866 1-866-252-8606 ® CSHelpsk: com 1 l- J '* Project Name: 00280 - Hancock Residence - Tree Top Trail I Qty 7 Truss: V3 Customer: Gillespie Builders SID: 0000258556 TID: 66489 Date: 05 / 23 / 18 Truss Mfr. Contact: Rick Mills Page: 1 of 1 1- 0 3-2-8 3-2-8 1 2 5/12 I 2x311 3x4% M M I I r-I rl 36.875" 2x14 I 3-2-8 1- 0 3-2-8 1 3 J J F 3-0-14 Plates -- Simpson Strong -Tie 20 go (AS20) or 18 go (AS18HS, AS18S5, or AS18S6) indica ed by •-181 Code/Design: FBC-2017/TPI-2014 -----------Snow Load Specs----------- -----�----Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Our Factors ASCE7-10 Ground Snow(Pg) = N/A ASCE7�10 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk at: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 1.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg DI'ms: L = 0.0 ft B = 0-0 ft 200 lb BC Accessible Ceiling: No Total 31.0 Plt 1.25 1.60 N/A Thermal Condition: All Others M.R.H(�) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Epclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind D{(psf): TC = 5.0 BC - 1.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind U lift Reporting: HybridMW OR Soffit Load: 2.0 PSF Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2 Reactions not shown: down < 400 and up < 150 TrussSpan Limit Actual(in) Location BC 2x4 SP (ALSC6-2013) 42 ---- Reaction Summary (plf) ----- Vert LL L/360 L/999(-0.00) 1- 3 Webs 2x4 SP (ALSC6-2013) #2 Jnt-Jnt React -Up- --Width- Vert CR L/240 L/999(-0.00) 1- 3 1- 3 61 70 3-00-14 Member Forces Summary Max Horiz - -11 / +59 at Joint 1 Horz LL 0.75in ( 0.00) @it 1 ..Mem... Ten Comp .CSI. Horz CR 1.25in ( 0.00) @Jt 1 TC 1- 2 19 34 0.07 Loads Summary 2-OH 0 3 0.00 This truss has been designed for the effects f an unbalanced top chord BC 1- 3 26 24 0.06 live load occurring at (30208) using a 1.00 F 11 and 0.00 Reduced load 3-OH 0 0 0.00 factor. Vert CR and Horz CR are the vertical and saeb 2- 3 117 58 0.03 Ind horizontal deflections due to live load See Loadcase Report for loading combinations additional details. plus the creep component of deflection Dead Loads may be slope adjusted: > 12.0/12 due to dead load, computed as Defl LL + (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. Notes Valley Truss application only Plates designed for Cq at 0.80 and Rotational olerance of 10.0 Bracing Data Summary degrees ------------Bracing Data ------------ Plates located at TC pitch breaks meet the pre criptive minimum size Chords; continuous except where shown requirement to transfer unblocked diaphragm loads across those joints. Web Bracing -- None Plate offsets (X, l): (None unless indicated below) �\CEN& * No. 76864 Q� •. ST COA#30003 5/23/2018 NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by lh Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. Aseal on this drawing indicates acceptance of Component Solutions professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General Notes' page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-276�. All connector plates are 20 gauge unless the is followed by "S# Truss Studio V Truss t 87 r r 2018.1.0.87 018.1.0 . 1-866-252-8606 1-866 252 specked plate size a'-18° which indicates an 18 gauge plate, or 18", which indicates a high tension 18 gauge plate. CSHelpsk: Strong -Tie INDIVIDUAL WEB REINFORCEMENT DETAIL I NOTES: 1. This detail provides web reinforcement options that may be used as an alternative to continuous lateral restraint (CLR) when installing CLRs in combination with diagonal bracing is not practical or desired. 2. Refer to the truss design drawing for web lateral restraint requirements. on the truss design drawing indicates that continuous lateral restraint is required at the locations shown (either at the midpoint or 1/3-points of the member). Refer to the tables below for acceptable web reinforcement opti that may be used in place of one or two rows of CLR. 3. This detail may not be used to substitute CLRs for T-, L-, I- or scab reinforcements that are specified on the truss design drawing. 4. T-, L-, I- and scab web reinforcements must be the same or better species grade of the web member as indicated on the truss design drawing. 5. All.reinforcements must extend to within 6" of each end of the web membe 6. This detail does not apply to single -ply webs that exceed 14' in length. (S) 1 Row of CLR @ Web Mid -point 2 Rows of CLRs @ Web 1/3 points _. WEB REINFORCEMENT OPTIONS FOR SINGLE -PLY TRUSSES' Specified Web Member Web Acceptable Web Reinforcement Reinforcement -to -Web Lateral Member Substitutions - Type & Size Connection Restraint Size Requirements (CLRs) T- L- Scab I- 2x4 2x4 2x4 2x4 --- I Row @ Mid-point 2x6 2x6 2x6 2x6 --- 2x8 I 2x8 2x8 2x8 --- 16d gun nails @ 6" on -center 2x4 2 2x4 2 Row @ 1/3-points No substitutions allowed 2x6 2-2x6 2x8 2-2x8 WEB REINFORCEMENT OPTIONS FOR 2-PLY TRUSSES' Specified Acceptable Web Reinforcement Web Member Web Substitutions - Type & Size Reinforcement -to -Web Lateral Member Connection Restraint Size Requirements (CLRs) T- L- Scab I- 2x4 2x4 2x4 --- --- 1 Row in 2x6 2x6 2x6 --- - - Mid -point 2x8 2x8 2x8 --- --- 16d gun nails @ 6" on -center 2x4 2-2x4 2 Row @ 1/3-points No substitutions allowed 2x6 2-2x6 2x8 I I 2-2x8 1. The maximum allowable web length for single -ply trusses is 14'. 2. For 2-ply trusses, the reinforcement must be nailed to both plies of the web with the nailing pattern specified in the table. 3. For the scab reinforcement, 2 rows of 10d gun nails @ 6" o.c may be used in plat of 16d gun nails for attaching the reinforcement to the web. 4. For I -reinforcement, attach each 2x_member to opposite edges of the web using the nailing pattern specified in the table. Nail Dimension 16d=3.5"x0.131" 10d=3"x0.120" D-WEBREINFORCE Date: 06/11/2014 1 Rev:A Web mber Typ•) i Add member to both edges for I -Reinforcement T- Reinforcement (I -Reinforcement similar) L- Reinforcement Scab Reinforcement L. GUN ocEN&F' * : No. 76864 � Q� •, 4s�mr c/// O111110 ona3000s NALS 23/2018 1 of 1 Phis detail Is to be used only for the application and conditions indicated herein, and its suitability for any particular trusslproject shall be verified (by others). This detail is not intended to Simpson Strong -Tie Company supersede any project -specific details provided in the Construction Documents. Truss configurations shown are for illustration only. Referlto the truss design drawing(s) accompanying his detail for specific truss design information. Simpson Strong -Tie Inc. is not responsible for any deviations from this design. SIMPSON Strong -Tie LATERAL RESTRAINT & DIAGONAL BRACING DETAILS FOR D-WEBCLRBRACE WEB MEMBERS This detail provides information for laterally restraining and bracing web members to prevent lateral buckling using continuous lateral restraints (CLRs) in combination with diagonal bracing. In addition to the CLRs indicated on the truss design drawing, diagonal bracing must be installed as indicated in this detail and BSCI-B3. See WEBREINFORCE for web reinforcement options that may be used as an alternative to this detail when installing CLRs and diagonal bracing is not practical or desired. Properly attached full-length sheathing satisfies (may replace) any bracing requirements specified for end vertical webs. Refer to the Construction Documents for additional bracing requirements. Install 2x4 diagc onrl nt m'nni 9(V Note: Not all truss vvenap enas of members shown for clarity. spacing or use For webs with one row of CLRs, diagonal bracing shall be installed using Option 2A or 2B. Attach diagonal braces to each truss with min. 2-10d nails. 45 Option 2A Option 2B Detail 2 - Diagonal Bracing for 1 Row of CLRs DETAIL LIMITATIONS: 1. Restraint and Bracing Material min. 2x4 stress graded lumber. 10d = 2. This detail does not address permanent building stability bracing to resist lateral forces acting on the building. 3. This detail shall not supersede any project -specific truss member permanent bracing design for the roof framing structural system. Date:06/18/2014 i Rev:A i Pg. 1 of 1 1 row of CLR @ mid -points 2 rows of CLR @ 1/3-points WEB MEMBERS WITH LATERAL RESTRAINT bracing at each end ig the length of the I Bracing Details 2 & 3. tin. 2x4xl2' CLRs installed n web members where idicated on the truss design rawing. Attach CLRs to each ,eb with min. 2-10d nails at least one truss detail (see Detail 1) Section A -A Web CLR splice CLR Min. 2'-long 2x_ scab block centered over the CLR splice and web. Attach to CLR with min. 8-10d nails on each side of splice. Detail 1 - CLR Splice webs with 2 rows of CLRs, diagonal bracing shall be 3Iled using Option 3A or 3B. Attach diagonal braces to h truss with min. 2-10d nails. ki Option 3A Option 3B Detail 3 - Diagonal Bracing for 2 Rows of CLRs L. G(IN�'�. 'OCENSk * No. 76864 *, -v C�**'�_�: ensions: p sT E F 01. COA 43000s 5/23/2018 This detail is to be used only for the application and conditions indicated herein, and its suitability for any particular trr, supersede any project -specific details provided in the Construction Documents. Truss configurations shown are for ill this detail for specific truss design information. Simpson Strong -Tie Inc. is not responsible for any deviations from this t shall be verified (by others). This detail is not intended to I Simpson Strong -Tie Company only. Refer to the truss design drawing(s) accompanying