HomeMy WebLinkAboutENERGY EFFICIENCY CODE,
FORM R405-2017
Alunoo Zion j, is
AS
RESIDENTIAL ENERGY CONlOW-1ON CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative (Performance) Method
Applications for compliance with the 2017 Florida Building Code, Energy Conservation via the
residential Simulated Performance Method shall include:
e
& This checklist
a M- A Form R405 report that documents that the Propos
R405.3 of the Florida Energy Code. This form shall i
indicating home address, a -ratio and the pass or fail
areas and types of components, whether the home t
orientation, name and version of the compliance soft
completing the compliance report (one page) and ar
be used for field verification (usually four pages/may
LAY Energy Performance Level (EPL) Display Card (one
e HVAC system sizing and selection based on ACCA i
CzY Mandatory Requirements (five pages)
Required prior to CO for the Performance Method:
id Design complies with Section
clude a summary page
status along with summary
(as simulated as a worst -case
ware tool, name of individual
input summary checklist that can
be greater).
S or per exceptions provided in Section R403.7
❑ Air Barrier and Insulation Inspection Component Criteria checklist (Table R402.4. 1. 1 -
one page)
I
❑ A completed Envelope Leakage Test Report (usually one page)
❑ If Form R405 duct leakage type indicates anythin, g other than "default leakage", then a completed
J& Form R405 Duct Leakage Test Report (usually one page)
FILE COPY
J-
1/25/2020 1:05:42 PM
EnergyGaugeO USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software
Page 1, of 1
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING
Florida Department of Business and Professional Regulation - Residential
CONSTRUCTION
Performance Method
Project Name: Missionary Flights 3`-Siti3 A s tlek; y
Builder Name:
Street: Hammond Rd & Steel Blvd, Site 2`
Permit Office:
City, State, Zip: Ft Pierce, FL , 34946
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, ST LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
9,Wall Types (1206.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=5.0 1206.00 ftz
3. Number of units, if multiple family 1
b. N/A
c. N/A
R= ftz
R= ftz
4. Number of Bedrooms 2
d. N/A
R= ftz
5. Is this a worst case? No
10. Ceiling Types (1077.0 sgft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 1077.00 ftz
6. Conditioned floor area above grade (ftz) 1077
b. N/A
R= ftz
Conditioned floor area below grade (ftz) 0
c. A
R= ftz
11. Ducts
R ftz
7. Windows(154.5 sgft.) Description Area
a. Sup: Cottage, Ret: Cottage, AH: Cottage 6 215.4
a. U-Factor: Dbl, U=1.00 154.50 ftz
SHGC: SHGC=0.40
b. U-Factor: N/A ftz
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
24.4 SEER:16.50
c. U-Factor: N/A ftz
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ftz
a. Electric Strip Heat
17.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 3.864 ft.
Area Weighted Average SHGC: 0.400
14. Hot water systems
8. Floor Types (1077.0 sgInsulation Area
a. Electric
Cap: 30 gallonsft.)
a. Slab -On -Grade Edge Insulation R=0.0 1077.00 ftz
b. Conservation features
EF: 0.950
b. N/A R= ftz
None
c. N/A R= ftz
15. Credits
Pstat
Total Proposed Modified Loads:
Glass/Floor Area: 0.143
41.41
PASS
Total Baseline Loads:
43.71
i
I hereby certify that the plans and specifications covered by
Review of the plans and
THE ST4,
this calculation are in compliance with the Florida Energy
specifications covered by this
FO
Code.
calculation indicates compliance
,y�
�- N 1�1
with the Florida Energy Code.
r�rr„�•,' : '"��,ti O
i.10
PREPARED BY: 1„1
Before construction is completed
DATE: - -
this ibuilding will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
FloridaStatutes.
1
with the Florida Energy Code.
G'0D WE�ty
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and thin project'requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). �•
r ,
I f� • �la1 r2
1/25/2020 1:05 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4:
FORM R405-2017 INPUT SUMMARY
CHECKLIST REPORT
PROJECT
i
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Missionary Flights 3-Site 2 Ac
User
1
Single-family
New (From Plans)
Bedrooms: 2
Conditioned Area: 1077
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation:
Whole House Fan:
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street: Hammond Rd & Steel B
County: St. Lucie
City, State, Zip: Ft Pierce ,
FL, 34946
CLIMATE
/
1/ Design Location TMY Site
Design
97.5
Temp
% 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST LUCIE_CO_INTL FL VERO_BEACH_MUNI 39
90
70 75 299 58 Medium
BLOCKS
Number
Name Area
Volume
1
Blockl 1077
9693
SPACES
i
Number
Name Area
Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Cottage 1077
9693 Yes
4
2 1 Yes Yes Yes
FLOORS
i
#
Floor Type Space
Perimeter RValue
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Cottage 133.5 ft
0
1077 ft2 0.5 0.5 0
ROOF
/
V #
Type Materials
Roof Gable
Area Area
Roof
Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Hip Flat file/slate
1167 ft2 0 ft2
Medium
N 0.96 No 0.9 No 20 22.6
ATTIC
V #
Type Ventilation Vent Ratio (1
in)
Area RBS IRCC
1
Full attic Unvented 0 1077 ft2 N N
CEILING,
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Unvented)
Cottage 0 Blown
1077 ft2 0.11 Wood
1/25/2020 1:05 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY
CHECKLIST REPORT
WALLS
Adjacent
Wall Type Space
Cavity Width Height
Ryalue Ft In Et In
Sheathing Framing Solar Below
Area R-Value Fraction-Absor(,rede°/
1 N
2 E
_ 3 S
_ 4 S
_ 5 W
Exterior Concrete Block - Int Insul Cottage
Exterior Concrete Block - Int Insul Cottage
Exterior Concrete Block - Int Insul Cottage
Exterior Concrete Block - Int Insul Cottage
Exterior Concrete Block - Int Insul Cottage
5 d1 9
5 2I6 9
5 10.5 9
5 30.5 9
5 2I6 9
369.0 ft2 1
234.0 ft2 1
94.5 ft2 1
274.5 ft2 1
234.0 ft2 1
0 0.75
0 0.75
0 0.75
0 0.75
0 0.75
0
0
0
0
0
DOORS
#
Omt Door Type Space
Storms U-Value Width
Ft In
Height
Ft In
Area
1
2
S Wood Cottage
W Wood Cottage
None .46
None .46
3
3
6.5
6.5
19.5 ft2
19.5 ft2
WINDOWS
Orientation shown is the entered,
Proposed orientation.
�/ #
Wall
Omt ID Frame Panes NFRC
U-Factor SHGC
I
Imp Area
Overhang
Depth Separation
Int Shade
Screening
1
2
3
4
5
N 1 Metal Double (Tinted) Yes
E 2 Metal Double (Tinted) Yes
S 3 Metal Double (Tinted) Yes
S 4 Metal Double (Tinted) Yes
S 4 Metal Double (Tinted) Yes
1 0.41
1 0.4
1 0.4
1 0.4
1 0.4
Y 30.0 ft2
Y 30.0 ft2
Y 15.0 ft2
Y 19.5 ft2
Y 60.0 ft2
2 ft 0 in 1.5 ft 0 in
1 ft 0 in 1.5 ft 0 in
2 ft 0 in 1.5 ft 0 in
6 ft 0 in 0.5 ft 0 in
6 ft 0 in 0.5 ft 0 in
None
None
None
None
None
None
None
None
None
None
INFILTRATION
# Scope
I
Method SLA CFM 50 ELA EgLA
ACH ACH 50
1 Wholehouse Proposed ACH(50) .000286 807.8 44.341 83.4
.1039
5
HEATING SYSTEM
i
#
System Type Subtype
I Efficiency Capacity
Block
Ducts
1
Electric Strip Heat/ None
COP:1 17 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/ Split
SEER: 16.5 24.4 kBtu/hr 732 cfm 0.75 1
sys#1
HOT WATER SYSTEM
#
System Type SubType Location
EF Cap Use
SetPnt
Conservation
1
Electric None Cottage
0.95 30 gal 50 gal
120 deg
None
1/25/2020 1:05 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC, 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SOLAR HOT WATER SYSTEM
i
FSEC
Collector Storage
Cert #
Company Name
System
Model # Collector Model
#
Area
Volume
FEF
None
None
ft2
DUCTS
/
— Supply
---
--- Return
--
I
Air
CFM
25 CFM25
HVAC #
V #
Location R-Value Area
Location
Area
Leakage Type
Handler
TOT OUT QN RLF
Heat Cool
1
Cottage
6 215.4 ft Cottage
53.85 ft
Default Leakage
Cottage
(Default) (Default)
1 1
TEMPERATURES
i
Programable Thermostat: Y
Ceiling Fans:
Cooling Jan
Heating Jan
HJan
Feb
HFeb
Mar
Mar
Apr
E Apr I
May
I May
Jun r Jul
n Jun [1 Jul
Aug
f 1 AuSeP
Sep
Oct
Oct
Nov
Nov
r , Dec
[X] Dec
Ventin
Feb
Mar
[Xl A r
May
Jun [[[ Jul
I
[ Aug
Se
[X] Oct
Nov
III 111 Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4
5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78 78
78
78 78
78
78
80
80
80
80
PM
80
80 78
78
78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78 78
78
78 78
78
78
78
78
78
78
PM
78
78 78
78
78 78
78
78
78
78
78
78
Heating(WD)
AM
66
66 66
66
66 I 68
68
68
68
68
68
68
PM
68
68 68
68
68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66 66
66
66 68
68
68
68
68
68
68
PM
68
68 68
68
68 68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ft2
O ft
0.3
Cottage
1125/20201:05 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE
ESTIMATED ENERGY
The lower the Energy Performance
1. New home or, addition
2. Single-family or multiple -family
3. No. of units (if multiple -family)
4. Number of bedrooms
5. Is this a worst case? (yes/no)
6. Conditioned floor area (sq. ft.)
1. New (From Pla Is)
i
2. Single-family
3. 1
(EPL) DISPLAY CARD
E INDEX* = 95
the more efficient the home.
12. Ducts, location & insulation level
a) Supply ducts R 6.0
b) Return ducts R 6.0
c) AHU location Cottage
4. 2 13. Cooling system:
Capacity 24.4
a) Split system
SEER 16.5
5. No b) Single package
SEER
c) Ground/water source SEER/COP
6. 1077 d) Room unit/PTAC
EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average) 7a. 1.000
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.400
c) Area 7c. 154.5
8. Skylights
a) U-factor:(weighted average) 8a. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b.
9c.
10A1.
10A2. 5.0
14. Heating system:
Capacity 17.0
a) Split system heat pump
HSPF
b) Single package heat pump HSPF
c) Electric resistance
COP 1.0
d) Gas furnace, natural gas
AFUE
e) Gas furnace, LPG
AFUE
f) Other
15. Water heating system
a) Electric resistance EF 0.95
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF
f) Heat recovery unit HeatRec%
g) Other
1061.
10132.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
1la. 0.0
b) Cross ventilation No
11b.
c) Whole house fan No
11c.
d) Multizone cooling credit
11d. No
e) Multizone heating credit
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Home: Hammond Rd & Steel Blvd, Site 2 City/FL Zip: Ft Pierce, FL 34946
1/25/2020 1:06:06 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Florida Building Code, Energy Conservation, 6th Edition (2017)
Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods
ADDRESS: Hammond Rd & Steel Blvd, Site 2 Permit Number:
Ft Pierce , FL, 34946
MANDATORY REQUIREMENTS See individual code sections for full details.
SECTION R401 GIENERAL
I,
R401.3 Energy Performance Level (EPL) display card (Mandatory).The building official shall require that an energy performance level (EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
(Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate code compliance for the building.i A copy of the EPL display card can be found in Appendix RD.
i
i
M ® R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
R402.4.1 Building thermal enveldj�r_ building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.
The sealing methods between dissimilar materials shall allow for differential expansion and contraction.
R402.4.1.1 InstallationTi he components of the building thermal envelope' as listed in Table R402.4.1.1 shall be installed in accordance
with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required
by the code official, an approved third party shall inspect all components and verify compliance.
ElR402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in
accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2, inch w.g. (50 pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(9, (g) or (i) or
an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing
buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or
other infiltration control measures.
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended
infiltration control measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
R402.4.2 Fireplaces. New wood-buming fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where
using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the
fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907.
R402.4.3 Fenestration air IeakageWindows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per
square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or
AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer.
Exception: Site -built windows, skylights and doors.
1/25/2020 1:06 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
MANDATORY REQUIREMENTS - (Continued)
R402.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to
open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or
enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements
of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be
fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it
passes through conditioned space to a minimum of R-8.
Exceptions:
1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside.
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential.
ElR402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces. All recessed luminaires shall be'' IC -rated and labeled as having an air leakage rate not
more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 11.57 psf (75 Pa) pressure differential. All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
l
SECTION R403 SYSTEMS
R403.1 Controls. i
R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls
that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load.
R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways
for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below.
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or
(7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(9, (g) or (i), Florida Statutes, to be "substantially leak free" in
accordance with Section R403.3.3.
R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent
of the design airflow rate when tested in accordance with ASHRAE 193.
R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods:
1. Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the
manufacturer's air handier enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test.
2. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the
entire system, including the manufacturer's air handier enclosure. Registers shall be taped or otherwise sealed during the
test.
Exceptions:
1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building
thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
❑ R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used' as ducts or plenums.
E-111403.4 Mechanical system piping Insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41°C)
or below 55°F (13°C) shall be insulated to a minimum of R-3.
R403.4.1 Protection of piping Insulation. Piping insulation exposed to weather shall be protected from damage, including that
caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause
degradation of the material. Adhesive tape shall not be permitted.
R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory)Heated water circulation systems shall be in
accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2.
Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible.
R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return
pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited.
Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the
occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and
when there is no demand for hot water.
R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems
shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance
with the times when heated water is used in the occupancy.
1/25/2020 1:06 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
MANDATORY REQUIREMENTS - (Continued)
R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3'/2 inches (89 mm) in the hot water ;distribution line and cold water line located as close as possible
to the storage tank.
R403.5.6 Water heater efficiencies (Mandatory).
R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature
setting range shall be from 100°F to 140°F (38'C to 60°C).
R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to
electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main bumer(s) of
combustion types of service water -heating systems to be turned off.'
R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate
water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1.
® R403.5.6.2.1 Solar water -heating systems. Solar systems for' domestic hot water production are rated by the annual solar energy
factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors,
and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar
water -heating systems should meet the following criteria: I
1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal; and
2. Be installed at an orientation within 45 degrees of true south.
R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code, Residential, or Florida Building Code, Mechanical, as ;applicable, or with other approved means of ventilation
including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that
close when the ventilation system is not operating.
ElR403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical
ventilation system, fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be
powered by an electronically commutated motor.
R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation
shall meet the following criteria:
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable
Indoor Air Quality, shall be the maximum rates allowed for residential applications.
2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawispaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10
otherwise.
R403.7 Heating and cooling equipment (Mandatory).
R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and
indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that
affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such
as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency
rating equal to or greater than the minimum required by federal law for the geographic location where the equipment Is installed.
TABLE R403.6.1
WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION
AIRFLOW RATE MINIMUM
(CFM)
MINIMUM EFFICACY a
(CFM/WATT)
AIRFLOW RATE MAXIMU
(CFM)
Range hoods
Any
2.8 cfm/watt
Any
In -line fan
Any
2.8 cfm/watt
Any
Bathroom, utility room
10
1.4 cfm/watt
<90
Bathroom, utility room
90
2.8 cfm/watt
Any
For SI: 1 cfm = 28.3 Umin, a. When tested in accordance with HVI Standard 916
1/25/2020 1:06 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
MANDATORY REQUIREMENTS - (Continued)
❑R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less
than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's
expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb
temperature for the load calculation (or entering water temperature for water -'source equipment), the blower CFM provided by the expanded
performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature.
i
Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space.
Exceptions:
1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the
2.
calculated total sensible load but not less than 80 percent of that load.
�
When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of
equipment may be sized in accordance with good design practice.
R403.7.1.2 Heating equipment capacity.
® R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1, and the heat pump total cooling capacity shall not be more�than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.7.1.
R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric bumers
shall not be less than the design load calculated in accordance with Section R403.7.1.
❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
❑ R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403.
❑ R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting -systems, supplied through energy service to the building,
shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (I VC), and no
precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.8°C).
- ❑ R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403.10.5.
R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an
integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation
of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the
power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots.
R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule
shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this
section.
Exceptions:
1. Where public health standards require 24-hour pump operation.
2. Pumps that operate solar- and waste -heat -recovery pool heating systems.
3. Where pumps are powered exclusively from on -site renewable generation.
❑ R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at
the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered
energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required.
❑ R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal
efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
1/25/2020 1:06 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
�l
❑ R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is
required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard.
R403.11 Mandato Portables as
p ( rYhe energy consumption ofelectric-powered portable spas shall be controlled by the
requirements of APSP-14.
SECTION R464
ELECTRICAL POWER AND LIGHTING SYSTEMS
R404.1 Lighting equipment (Mandatory). Not less than 75 percent of the�i lamps in permanently installed lighting fixtures shall be
high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps.
Exception: Low -voltage lighting.
R404.1.1 Lighting equipment (Mandatory)Fuel gas lighting systems shall not have continuously burning pilot lights.
,I
1/25/2020 1:06 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
Missionary Flights 3-Cottage Site 2 Accessible
Ft Pierce, FL
MANUAL'J'/ASHRAE CALCULATION RESULTS
SUMMER O.A./I.A. - 91 DEG. D.B.175 DEG. D.B.
WINTER O.A./I.A. - 47 DEG. D.B./70 DEG. D.B.
system room room
1.00 num name
1 Bedroom 1
2 Bath 1
3 Bath 2
4 Bedroom 2
5 Kitchen/Dining/Family R
60 -
60 -
SUB TOTALS
TOTALS
Jones & Conde, LLC
4440 PGA Boulevard
Palm Beach Gardens, FL 33410
Certificate of Authorization #29783
Tel (561) 309-9017
Engineer: David R Jones, PE #41042
approx
kw calc
total cfm
I
heat tons
3269.57
�120
0.66
665.39
24
0.15
640.86
i 23
0.15
3225.52
118
0.54
14329.65
525
2.32
0.00
0
0.00
0.00
0
0.00
22131.00
8,11
3.81
22131.00
1
I
I
�I
1.9
Planning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
Project Name: Missionary Flights InternationaiV.A_c gsslble Cottages Uriit 2 , ,
-�_ ,
Project Address: Hammond Road & Steel Blvd., Ft. Pierce, FL 34946
Permit #: Occupancy Type: Construction Type:
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE; Florida Building Code f kh Edition with 20 17 Supplements using ASCE 7-10
2. Structure Designed as (check one): xx Enclosed Partially Enclosed Open
3. Risk Category: _I xx II III IV Exposure Category: B xx C D
4. Design Wind Velocity 160 mph ASD xx 'LRFD End Zone Width: 3 ft
S. Mean Roof Height 13 ft Roof Pitch., 6 :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: +130-33.5 Zone 2: +13.6/-56.2 Zone 3: +13.6/-84.6 Zone 4: +30.6/-33.2 Zone 5: +30.6/.40.9 Garage: N/A
7. Design Loads: Floor: N/A PSF Roof/Dead: 35 PSF Roof/Live: 20 Balcony: wa PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF
8. Were Shear Walls Considered For Structure? xx Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT,
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify'that structural elements depicted on these plans provide adequate resistance to the design
forces specified:''
Allen Wieder FL PE 43444
Print Name Cert # & Co. Cert Auth.
/Z Wieder Engineering, Inc. �py
Signature, Date, and Seal 11718 SE Federal Hwy #373, Hobe Sound, FL 33455
Company Name & Address
Revised 07/25/2014
Building Permit #
Planning & Development Services Department
Building & Regulations Division
Product Review Affidavit
1909-0087 Owners Name Missionary Flights International
Applicant:
Cottage No: 2
Product
Opening Design
Pressures
Product Rated
Design Pressure
Manufacturer
Model Number
Product Approval
Number
Glass
Type
Method of Attachment
Windows
+37.1 PSF/-49.0 PSF
+79.0 PSF/-79.0 PSF
PGT Industries
SH 700
NOA# 17-0630.08
B
1/4" elco SS4 crete flex. Spacing per Product A •val
Mullions
+35.3 PSF/-45.5 PSF
+64.7 PSF/-64.7 PSF
PGT Industries
PGT clipped extruded at.
NOA# 17-0630.01
N/A
2x5 angle clips w/ (4) 3/16" ultracon anchors min. edge disc 111.
Fixed Glass
""
--
"—
--
--
--
LU
Siding
+45.9 PSF/ PSF
+76 PSF/ PSF
James Hardie
Hadie Panel Cem anel
p
NOA# 17-0821.21
N/A
2-lon 0.223"headdiameter.0.092"shank diameter, corrosion resistant al Spacing per 1
s siding i. p Mp pp —al
Skylights
--
--
--
--
--
--
--
Sliding Glass Doors
--
--
--
Swing Type Doors
_
+36.2 PSF/-39.4 PSF
+55.0 PSF/-55.0 PSF
JELD-WEN
Contours steel door
FL# 11136-R7
N/A
1/4"ITWflat head tapconanchor w/2"min. embedment. Butterfly anchor (4)reci'd.per jamb 61/6"from B&26.75"0.C.
French Doors
--
--
-
Garage Doors
--
--
--
Hurricane Protection
Roof Ventilation
Roofing Material
Field-12 PSF. Perimeter-108 PSF
Field-95.5 PSF. Permcler-14425 PSF
Brock Associates, LLC
Snap CLad24Gax 16"
NOA# 15-0327.06
NSA
Panelsha110ei-.Nadal... thorib-nap claddIpssocured-10.15`tastener5(2 per clip for individual clip: a per dip for cool
Revised 07/22/2014
I have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the
wind loads and forces specified by current code provisions.
Name: Stephan Claren Signature: A seal
Design Prof: Architect
Cert. No. AR95258 Date: 01-02-2020