HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEC-SCA1_n1 lnj
nnig & Development Services Department
of B rein & Code Regulations Division
bb��i�g,nla ���enue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
Project Name: Missionary Flights International - Cottages nit L&r thr
Project Address: Hammond Road & Steel Blvd., Ft. Pierce, FL 34946
Permit #: Occupancy Type: Construction Type:
INSTRUCTIONS FOR USE: I
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building peiimit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete
1. DESIGN CODE: Florida Building
Code fifth Editii
2. Structure Designed as (check one):
xx - Enclosed
3. Risk Category: _I xx 11
III IV
4. Design Wind Velocity 160
mph ASD roc
5. Mean Roof Height 13
ft Roof Pit
6. Components & Cladding Design Pressures Used: (PSF, base
Zone 1: *1&6/33.s Zone 2: *13.6/-%.2
Zone 3: +13.8/"84.e i
7. Design Loads: Floor: N/A PSF
Roof/Dead: 35
Dock: N/A PSF Deck: N/A PSF Stairs: N/A
8. Were Shear Walls Considered For Structure? xx Yes
all that apply)
n with 20 17 Supplements using ASCE 7-10
Partially Enclosed Open
posure Category: B xx C D
.RFD End Zone Width: 3 ft
6 :12 Parapet Id/A ft
on 10sgft @ 15'MRH, clearly label on all plan openings):
1e 4: +300-3s.2 Zone 5: +30.6140.9 Garage: N/A
_PSF Roof/Live: 20 Balcony: WA PSF
F Fence: N/A PSF Railings: N/A PSF
_Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? � Yes Not Applicable Explain Why Not:
_ I
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County, I also certifV.that structural elements depicted on these plans provide adequate resistance to the design
forces specified:.; ,
Allen Wieder FL PE 43444
A=iit�L
Signature, Date, and Seal
Revised 07/25/2014
Print Name
Wieder Engineering, Inc.
Cert # & Co. Cert Auth.
11718 SE Federal Hwy #373, Hobe Sound, FL 33455
Company Name & Address