Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFINGFlorida Building Code Online i Page 1 of 4 BCIS Home I Log In I User Registration I Hot Topics I Florida o r*, Product Approval usER: Public User ET� nfir�ts Product Approval Menu > Product or Application Search > FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method SCANNED BY - - - St Lucie rOU* Surcharge I Stats & Facts I Publications I FBC Staff I BCIS Site Map I Links I Search > Application Detail FL17022-R7 Revision 2017 Approved 08/18/2017v. date reapply 08/21/17 El Extreme Metal Fabricators, LLC 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 flvalidation@yahoo.com Richard McKuhen flvalidation@yahoo.com Richard McKuhen 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 rchard@emfab.net Roofing Metal Roofing RECEIVED MAY 0 3 2018 ST, Lucie County, Permitting Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed LOCKE BOWDEN the Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Zachary R. Priest, P.E. 11 Validation Checklist - Hardcopy Received Certificate of Independence I FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.odf I Referenced Standard and Year (of Standard) Standard Year TAS 125 2003 UL 1897 2012 UL 580 2006 Equivalence of Product Standards I Certified By Sections from the Code I I i I https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZ... 5/3/2018 Compliant with Florida Building Code 2017 (6th ed.) Compliant with Florida Product Approval R le # 61G20-3 Compliant: Keystone Certifications Product: 5 V Crimp 26GA Steel Roof Panel Yield strength: 50 ksi min.; Attad Deck w/ min. 0.42 specific gravity Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec.1 Fastener 1(Method 1 Attachment): #9 x 1 3/16" min. thru deck or 5/8" embedment requirements) Fastener 2 (Method 2,3, & 4 Attachment): penetrate 3/26" min. thru deck or 5/8" en to meet requirements) Underlayment: To be compliant with FBC Slope: Shall be in compliance with FBC Palm City, FL 34990 :BC Sec. 1507.4.2 ed to min.15/32" plywood or Wood with screws. 24" Coverage 07.4.3 12" Hex -Washer Head wood screw* to penetrate ito wood plank. (*or sufficient length to meet x 1-1/2" Hex -Washer Head wood screw* to ment into wood plank. (*or sufficient length Chart 1507.1.1 1507. See Fastener attachment specifications above Install Details: Table A Allowable Loads METHOD 1 METHOD 2 ;: METHOD 3.. METHOD_4 DESIGN PRESSURE*_. -86 PSF _ ., -93.5 PSF -101 PSF -228 PSF ROW SPACING . _... ..... _ _ ., ._ 46",pope, 16" o.c.. 8" o.c. 6" ox. FASTENER SPACING (ALONG Panel width) 12" O.C. 12" o.c. _. , 12" o.c. 12" o.c. FASTENER SIZE _ _ ;',_. #9 #10 #10 , #10 Reference Data: ARCHITECTURAL TESTING, INC. TST ID#:1527 UL 580-06 & 1897-041 Test Report CM893.01-450-18 05/02/14 Test Report F3366.01-450-18 12/18/15 TAS 125-03 Test Report D05893.02-450-18 07/22/14 *EQUIVALENCY-UL 1897-04 is equivalent to test standard UL 1897-I �f� *Design pressure margin of safety 2.1 Locke Bowden, P.E. does not have, not will acquire a financial int�q' ��cqn mfWfacturing or distributing products under this evaluation. = �• Locke Bowden, P.E. is not owned, operated, or controlled 1by aQy coo par(VorM4fdafsttur'•es, or dstributing products under this • report. «, X . • . .,• �• S TL, • FL17022.1 6V Crimp (26GA 1), 24" Wide Roof Panel - Details Limitations: 1. Underlayment to be compliance with current Florida Buil 2. Minimum slope to be compliant with Florida Building Coi 3. Products are compliant for State of Florida product appr 4. Engineering analysis for "project specific approval by loc 5. Fire classification is not part of this acceptance. Shear d 6. Support framing in compliance w/FBC 2017 6th ed., Cha Structural Loading. 7. This report does not imply warranty, installation, recomn Dedc: 15132" or greater Plywood, or Wood plank ig Code (FBC)2017 6th ed. 2017 6th ed., and per with Manufacturer's installation reference. 31 per Rule 61G20-3. Compliance Method: 1-D authorities w/jurisdiction is allowed by other registered engineers. >hragm values are outside this report. :r 22 for Steel, Chapter 23 for Wood and Chapter 16 for ed product use outside of this report. ramcnaa- #9 x 1L 112" Min. or #10 � 1-112" Min. perTab/e A" for Row 5-V Crimp Roof Panel Spacing and Design Pressures Hex V1lasher Head Wood Screws 24- '12" OFTIONAI. STRIATIONS Panel Profile Nominal12" I Nominal12" Fasten ' J1937-1/2" Min. or #10 X 1-1/2" Min. per -Table "A" Hex Washer Head Screw Spaced 12" o.c. across the Panel Wdth Panel Refer to Table "A" for Spacing Along Panel Overlap /\ Length Deck-15/32" or greater Plywood, or - VAbod plank