Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 SCANNED Certification for Design Load Compliance Proje NamBYAcquaVista Lot 1- Single Family Residence .ucic� 6-013My Project Address: 4410 North Al (Hutchinson Island); Fort Pierce, Florida 34949 (St. Lucie Co.) Permit #: Occlupancy Type: R-3 Construction Type: Type Vb INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies,for commercial with all permit al: lications involving the following: o New Residences (single or multi -family) RECEIVED o Residential Addition o Any accessory structure requiring la building permit JAN 2, 5 Luly o Any non-residential structure. ST. Lucie Count Per' 'ttin * Note: Form not required for interior renovations provided that no exterior st — and certain minor building permits at the discretion i of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Fifth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): X !Enclosed Partially Enclosed Open i 3. Risk Category: _I X II III IV Exposure Category: B C X D i 4. Design Wind Velocity 170 Vult mph I X ASD LRFD End Zone Width: 5.1 ft 5. Mean Roof Height 30' ft Roof Pitch: 4.5 :12 3 0 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 13'MRH, clearly label on all plan openings): Zone 1: -47.4 Zone 2: -82.4 Zone 3: -82.4 Zone 4: -56.1 Zone 5: -69.3 Garage: -52.1 7. Design Loads: Floor: 55 PSF Roof/Dead: 25 PSF Roof/Live: 20 Balcony: 100 PSF Dock: N/A PSF Deck: 100 PSF Stairs: 60 PSF Fence: N/A PSF Railings: 200 PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: David S. Knight, P.E. 41060 Print Name Cert # & Co. Cert Auth. -?0)NOV 1 G 2018 Knight McGuire & Associates, Inc. Signature, Date, and Seal Revised 07/25/2014 80 Royal Palm Pointe Suite 401; Vero Beach, FL 32960 (Company Name & Address I