HomeMy WebLinkAboutELEVATION CERTIFICATE 10-21-211W U.S. DEPARTMENT OF HOMELAND SECURITY SCANNED Federal Emergency Management Agency 13Y OMB No. 1 ate: Nov g y g g y Expiration Date: November 30, 2022 National Flood Insurance Program 4� t Lucie County ELEVATION CERTIFICATE Important: Follow the instructions on pages 1-9. Copy all pages of this Elevation Certificate and all attachml nts for (1) community official, (2) insurance agent/company, and (3) building owner. SECTION A — PROPERTY jINFORMATION FOR INSURANCE COMPANY USE Al. Building Owner's Name Policy Number: Venetian Administration, LLC I A2. Building Street Address (including Apt., Unit, Suitg, and/or Bldg. No.) or P.O. Route and Company NAIC Number: Box No. I 4410 N Highway Al City State ZIP Code Fort Pierce Florida 34949 I A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) Lot 1, Block A, Queens Island Preserve, Recorded in PB 60 PG 4, St Lucie County, FL A4. Building Use (e.g., Residential, Non -Residential Addition, Accessory, etc.) Residential A5. Latitude/Longitude: Lat. 27D 30M 54.03S N Long. 80D 18M 29.03S W Horizontal Datum: ❑ NAD 1927 ❑x NAD 1983 A6. Attach at least 2 photographs of the building if t e Certificate is being used to obtain flood insurance. A7. Building Diagram Number 1B A8. For a building with a crawlspace or enclosure(s; : a) Square footage of crawlspace or enclosures) N/A sq ft b) Number of permanent flood openings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade 16 c) Total net area of flood openings in A8.b 1958.00 sq in i d) Engineered flood openings? ❑x Yes ❑ No A9. For a building with an attached garage: a) Square footage of attached garage 1800.00 sq ft b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade 6 c) Total net area of flood openings in A9.b I 770.00 sq in I d) Engineered flood openings? ❑x Yes ❑ No SECTION B — FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number B2. County Name B3. State St. Lucie County 120285 I St. Lucie County Florida B4. Map/Panel B5. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) Number Date Effective/ Zone(s) (Zone AO, use Base Flood Depth) Revised Date 12111 C0093 K 02-19-2020 02-19-202b VE 11 B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9: ❑ FIS Profile ❑x FIRM ❑ Community Determined ❑ Other/Source: B11. Indicate elevation datum used for BFE in Item B9: ❑ NGVD 1929 ❑x NAVD 1988 ❑ Other/Source: B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes ❑x No Designation Date: I ❑ CBRS ❑ OPA I FEMA Form 086-0-33 (12/19) 1 Replaces all previous editions. Form Page 1 of 6 i ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2022 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/¢r Bldg. No.) or P.O. Route and Box No. Policy Number: 4410 N Highway A1A City State ZIP Code Company NAIC Number Fort Pierce Florida 34949 SECTION C - BUILDING INFORMATION (SURVEY REQUIRED) (ELEVATION C1. Building elevations are based on: ❑ Constru Drawings" ❑ Building Under Construction" NFinished Construction ICtion *A new Elevation Certificate will be required whenl construction of the building is complete. C2. Elevations - Zones Al-A30, AE, AH, A (with BFE), VE, V1-V30, V (with BFE), AR, AR/A, AR/AE, AR/A1-A30, AR/AH, AR/AO. Complete Items C2.a-h below according to the building diagram specified in Item A7. In Puerto Rico only, enter meters. Benchmark Utilized: NGS N 633 Elev 5.33 I Vertical Datum: NAVD 1988 Indicate elevation datum used for the elevations lin items a) through h) below. ❑ NGVD 1929 0 NAVD 1988 ❑ Other/Source: Datum used for building elevations must be the same as that used for the BFE. Check the measurement used. a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 13.0 0 feet ❑ meters b) Top of the next higher floor I 24.0 0 feet ❑ meters c) Bottom of the lowest horizontal structural member (V Zones only) 22.0 0 feet ❑ meters d) Attached garage (top of slab) I 9.0 x❑ feet ❑ meters e) Lowest elevation of machinery or equipment servicing the building (Describe type of equipment and location i Comments) 16.1 0 feet ❑ meters f) Lowest adjacent (finished) grade next to b ilding (LAG) 8.8 ❑x feet ❑ meters g) Highest adjacent (finished) grade next to b ilding (HAG) 12.6 ❑x feet ❑meters h) Lowest adjacent grade at lowest elevation of deck or stairs, including 9,6 ❑ feet ❑ meters structural support I SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. Were latitude and longitude in Section A provided by a licensed land surveyor? ❑x Yes ❑ No ❑ Check-here.if attachments. Certifier's Name I License Number Robert Kemerson, PSM 6285 Title Professional Surveyor & Mapperace ` -- t ' �• _- Company Name - Velcon Engineering & Surveying, LLC ,`�^_-�- - u;'!= . • �:: ` ' :' �r ~� Address .. I 1449 Commerce Centre Drive _ - _ ; ' City State ZIP Code Port St Lucie I Florida 34986 Signature I Date Telephone Ext. 10-21-2021 (772) 879-0477 Copy all pages of this Elevation Certificate and ally attachments for (1) community official, (2) insurance agent/company, and (3) building owner. Comments (including type of equipment and location, per C2(e), if applicable) C2 - Benchmark used is a NGS Vertical Control Point "N633" Elev 5.33 NAVD C2(e) - Slab 12.5 - Bottom of AC mounted on brackets is 16.07 C2(h) - Bottom Landing at NE Bldg corner is 12.3; Elevation where walk meets stairs at entry is 9.60 22 Total permanent flood openings 22. 16 flood openings within 1.0 foot above adjacent grade. Section A(9) - Smart vent.model number is 1540-510 - (9) x 200 = 1800 sq ft coverage based on ICC-ES Evaluation Report attached. Section D - Lattitude and Longitude determined by measure from Geo- Referenced Digital Ortho FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 2 of 6 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2022 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/ir Bldg. No.) or P.O. Route and Box No. Policy Number: 4410 N Highway AlA City State ZIP Code Company NAIC Number Fort Pierce Florida 34949 SECTION E — BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONEIAO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items E1 �E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B,and C. For Items El—E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. El. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. b) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the LAG. E2. For Building Diagrams 6-9 with permanent flood o enings provided in Section A Items 8 and/or 9 (see pages 1-2 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E3. Attached garage (top of slab) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E4. Top of platform of machinery and/or equipment servicing the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E5. Zone AO only: If no flood depth number is availab e, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F — PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner or Owner's Authorized Representativi 's Name Address I City State ZIP Code Signature I Date Telephone Comments ❑ Check here if attachments. FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 3 of 6 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2022 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/ir Bldg. No.) or P.O. Route and Box No. Policy Number: 4410 N Highway Al City State ZIP Code Company NAIC Number Fort Pierce Florida 34949 SECTION G — CbMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8—G10. In Puerto Rico only, enter meters. G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by la to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2 ❑ A community official completed Section E for a building located in Zone A (without a FEMA-issued or community -issued BFE) or Zone AO. G3. ❑ The following information (Items G4—G10) is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued G6. Date Certificate of Compliance/Occupancy Issued G7. This has been issued for: ❑ New Construction ❑ Substantial Improvement permit G8. Elevation of as -built lowest floor (including base lent) of the building: E]feet E]meters Datum G9. BFE or (in Zone AO) depth of flooding at the building site: ❑ feet ❑ meters Datum G10. Community's design flood elevation: ❑ feet ❑ meters Datum Local Official's Name I Title Community Name I Telephone Signature Date Comments (including type of equipment and location, per C2(e), if applicable) ❑ Check here if attachments. FEMA Form 086-0-33 (12/19) 1 Replaces all previous editions. Form Page 4 of 6 ELEVATION CERTIFICATE i BUILDING PHOTOGRAPHS See Instructions for Item A6. OMB No. 1660-0008 Expiration Date: November 30, 2022 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/ r Bldg. No.) or P.O. Route and Box No. Policy Number: 4410 N Highway Al City State ZIP Code Company NAIC Number Fort Pierce Florida 34949 If using the Elevation Certificate to obtain NFIP flolod insurance, affix at least 2 building photographs below according to the instructions for Item A6. Identify all photographs with date taken; "Front View" and 'Rear View"; and, if required, 'Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page. 6 1 �� ■ 41 Photo One Photo One Caption Front View -Date Taken 09-7-2021 Clear Photo One f Photo Two Photo Two Caption Rear View - Date.Taken 09-7-2021 Clear Photo Two FEMA Form 086-0-33 (12/19) 1 Replaces all previous editions. Form Page 5 of 6 ELEVATION CERTIFICATE BUILLANU PHOTOGRAPHS Continuation Page OMB No. 1660-0008 Expiration Date: November 30, 2022 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/ r Bldg. No.) or P.O. Route and Box No. Policy Number: 4410 N Highway A1A i City State ZIP Code Company NAIC Number Fort Pierce Fla rida 34949 If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front View" and "Rear View'; and, if required, Right Side View and Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. t .. 19 4 Photo Three Photo Three Caption Right Side View - Date Taken 9i 7-21 I Clear Photo Three � III I r: Photo Four Photo Four Caption Left Side View -Date taken 09-7-21 I Clear Photo Four FEMA Form 086-0-33 (12/19) 1 Replaces all previous editions. Form Page 6 of 6 4410 N. Highway A1A, Fort Pierce, FL 34949 1 • 4 J Flood Vents — Left side of house — Date Taken 4 1 t Flood Vents — Back of the house — Date Taken—10/20/2021 )14,a 4, . . . . . NS .1 1%, r- I p S Tit IA�k .1 IL All —Tis -- - I Ae F21 ES ICC-ES Evaluation Report ES R-2074 Reissued February 2021 This report is subject to renewal February 2023. www.icc-es.org 1 (800) 423-6587 1 (562)1699-0543 A Subsidiary of the International Code Council® DIVISION: 08 00 00—OPENINGS Section: 08 95 43—Vents/Foundation Flood REPORT HOLDER: SMART VENT PRODUCTS, INC. EVALUATION SUBJECT: SMART VENT® AUTOMATIC FOUNDATION FLC VENTS: MODELS #1540-520; #1540Z21; #1540- 511; #1540-570; #1540-574; #1540-524; #1540Z1 FLOOD VENT SEALING KIT #1540-526 1.0 EVALUATION SCOPE Compliance with the following codes: ■ 2018, 2015, 2012, 2009 and 2006 Internz Code® (IBC) ■ 2018, 2015, 2012, 2009 and 2006 Residential Code® (IRC) Each unit is fabricated from stainless steel. Smart Vent® Automatic Foundation Flood Vents are available in various models and sizes as described in Table 1. The SmartVENr Stacking Model #1540-511 and FloodVENT® Stacking Model #1540-521 units each contain two vertically arranged openings per unit. 3.2 Engineered Opening: The FVs comply with the design principle noted in Section D 2.7.2.2 and Section 2.7.3 of ASCE/SEI 24-14 [Section 0; #1540- 2.6.2.2 of ASCE/SEI 24-05 (2012, 2009, 2006 IBC and IRC)] for a maximum rate of rise and fall of 5.0 feet per hour (0.423 mm/s). In order to comply with the engineered opening requirement of ASCE/SEI 24, Smart Vent FVs must be installed in accordance with Section 4.0. Building ■ 2018 International Energy Conservation Code® (IECC) ■ 2013 Abu Dhabi Intemational Building Codel (AD IBC)t Me ADIBC is based on the 2009 IBC. 2009 IBC code s in this report are the same sections in the ADIBC. Properties evaluated: ■ Physical operation ■ Water flow 2.0 USES The Smart Vent® units are engineered operated flood vents (FVs) employed hydrostatic pressure on walls of enclosui rising or falling flood waters. Certain mod natural ventilation. 3.0 DESCRIPTION 3.1 General: When subjected to rising water, the Sm internal floats are activated, then pivot open either direction to equalize water level a pressure from one side of the foundation to FV pivoting door is normally held in the cla a buoyant release device. When subjected the buoyant release device causes the L allowing the door to rotate out of the way ; The water level stabilizes, equalizing the ons referenced mechanically to equalize s subject to s also allow Irt Vent® FVs o allow flow in id hydrostatic the other. The ed position by o rising water, iit to unlatch, nd allow flow. lateral forces. 3.3 Ventilation: The SmartVENT® Model #1540-510 and SmartVENr Overhead Door Model #1540-514 both have screen covers with 1/4-inch-by-1/4-inch (6.35 by 6.35 mm) openings, yielding 51 square inches (32 903 mm2) of net free area to supply natural ventilation. The SmartVENr Stacking Model #1540-511 consists of two Model #1540-510 units in one assembly, and provides 102 square inches (65 806 mm2) of net free area to supply natural ventilation. Other FVs recognized in this report do not offer natural ventilation. 3.4 Flood Vent Sealing Kit: The Flood Vent Sealing Kit Model #1540-526 is used with SmartVENr Model #1540-520. It is a Homasote 440 Sound Barrier® (ESR-1374) insert with 21 — 2-inch-by-2- inch (51 mm x 51 mm) squares cut in it. See Figure 4. 4.0 DESIGN AND INSTALLATION 4.1 SmartVENT® and FloodVENT®: SmartVENr and FloodVENT® are designed to be installed into walls or overhead doors of existing or new construction from the exterior side. Installation of the vents must be in accordance with the manufacturer's instructions, the applicable code and this report. Installation clips allow mounting in masonry and concrete walls of any thickness. In order to comply with the engineered opening design principle noted in Section 2.7.2.2 and 2.7.3 of ASCE/SEI 24-14 [Section 2.6.2.2 of ASCE/SEI 24-05 (2012, 2009, 2006 IBC and IRC)], the Smart Vent® FVs must be installed as follows: ■ With a minimum of two openings on different sides of each enclosed area. ■ With a minimum of one FV for every 200 square ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommenda}ion for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as ' to any finding or other matter in this report, or as to any producf covered by the report. prt� V m wucw.ur Copyright© 2021 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 5 t-2074 1 Most model and Trusted 2of5 feet (18.6 m) of enclosed area, except that the SmartVENr Stacking Model #1540-5111 and FloodVENr Stacking Model #1540-521 1 ust be installed with a minimum of one FV for every 400 square feet (37.2 mz) of enclosed area. I ■ Below the base flood elevation. ■ With the bottom of the FV located a maximum of 12 inches (305.4 mm) above the higher ofl the final grade or floor and finished exterior grade i mediately under each opening. 4.2 Flood Vent Sealing Kit The Flood Vent Sealing Kit Model 1540-526 s used in conjunction with FloodVENT® Model #1540-520. When installed and tested in accordance with ASTMIE283, the FV and Flood Vent Sealing Kit assembly have an air leakage rate of less than 0.2 cubic feet per minute per lineal foot (18.56 I/min per lineal meter) at a pressure differential of 1 pound per square foot (50 Pa) based on 12.58 lineal feet (3.8 lineal meters) contained bar the Flood Vent Sealing Kit. 5.0 CONDITIONS OF USE The Smart Vent® FVs described in this report Jomply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, su ject to the following conditions: 5.1 The Smart Vent® FVs must be installed in accordance with this report, the applicable code and the manufacturer's installation instructions. In the event of a conflict, the instructions in this report go ern. 5.2 The Smart Vent® FVs must not be used in the place of "breakaway walls" in coastal high hazard areas, but are permitted for use in conjunction with breakaway walls in other areas. 6.0 EVIDENCE SUBMITTED 6.1 Data in accordance with the ICC-ES Acceptance Criteria for Mechanically Operated Flood Vents (AC364), dated August 2015 (editorially revised October 2017). 6.2 Test report on air infiltration in accordance with ASTM E283. 7.0 IDENTIFICATION 7.1 The Smart VENT® models and the Flood Vent Sealing Kit recognized in this report must be identified by a label bearing the manufacturer's name (Smartvent Products, Inc.), the model number, and the evaluation report number (ESR-2074). 7.2 The report holders contact information is the following: SMART VENT PRODUCTS, INC. 430 ANDBRO DRIVE, UNIT 1 PITMAN, NEW JERSEY 08071 (877) 441-8368 www.smartvent.com infoAsmartvent.com TABLE 1—MODEL SIZES MODEL NAME MODEL NUMBER MODEL SIZE (in.) COVERAGE (sq. ft.) FloodVEN 1540-520 153/4" X 73/4" 200 SmartVENT® 11540-510 153/4' X 73/4' 200 FloodVENT® Overhead Door 1540-524 153/4' X 73/4' 200 SmartVENr Overhead Door 11540-514 153/4' X 73/4' 200 Wood Wall FloodVENr 1540-570 14" X 83/4' 200 Wood Wall FloodVENr Overhead Door I 1540-574 14" X 83/4' 200 SmartVENr Stacker I 1540-511 16" X 16" 400 FloodVent® Stacker 1540-521 16" X 16" 400 For SI: 1 inch = 25.4 mm; 1 squa ESR-2074 I Most i oted and Trusted ! Page 3 of 5 FIGURE 3—SMART VENT: SHOWN WITH FLOOD DOOR PIVOTED OPEN € ' ". '' �i. a,•E . I ' kikt S.i x ri h, rh ' INTERIOR ' EXTERIOR . z. FIGURE 4—FLOOD VENT SEALING KIT ES ICC-ES Evaluation Report ESR-2074 CBC and CRC Supplement Reissued February 2021 This report is subject to renewal February 2023. www.icc-es.org 1 (800) 423-6587 1 (562)I699-0543 A Subsidiary of the International Code Council® DIVISION: 08 00 00—OPENINGS Section: 08 95 43—Vents/Foundation Flood REPORT HOLDER: SMART VENT PRODUCTS, INC. EVALUATION SUBJECT: SMART VENT° AUTOMATIC FOUNDATION 1 570; #1540-574; #1540-524; #1540-514 FLOOD VENT SEALING KIT #1540-526 1.0 REPORT PURPOSE AND SCOPE VENTS: MODELS #1540-520; #1540-521; #1540-510; #1540-511; #1540- Purpose: The purpose of this evaluation report supple ent is to indicate that Smart Vent® Automatic Foundation Flood Vents, described in ICC-ES evaluation report ESR-2074, have also been evaluated for compliance with codes noted below. Applicable code edition: ■ 2016 California Building Code (CBC) ■ 2016 California Residential Code (CRC) 2.0 CONCLUSIONS 2.1 CBC: The Smart Vent® Automatic Foundation Flood Vents, described in Sections 2.0 through 7.0 of the evaluation report ESR- 2074, comply with 2016 CBC Chapter 12, provided the design and installation are in accordance with the 2015 International Building Code® (IBC) provisions noted in the evaluation report and the additional requirements of CBC Chapters 12, 16 and 16A, as applicable. I 2.2 CRC: The Smart Vent® Automatic Foundation Flo( 2074, comply with the 2016 CRC, provide Residential Code® (IRC) provisions noted in I This supplement expires concurrently with the i Vents, described in Sections 2.0 through 7.0 of the evaluation report ESR- the design and installation are in accordance with the 2015 International evaluation report. n report, reissued February 2021. ICC-ES Evaluation Reports are not to be construed as represent ng aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a reconunendat'on for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product( covered by the report. Copyright© 2021 ICC Evaluation Service, LLC. All rights " Iv. em wi[�co�nai .,w, Page 4 of 5 ES ICC-ES Evaluation Report ESR-2074 FBC Supplement Reissued February 2021 This report is subject to renewal February 2023. www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council° DIVISION: 08 00 00—OPENINGS Section: 08 95 43—Vents/Foundation Flood REPORT HOLDER: SMART VENT PRODUCTS, INC. EVALUATION SUBJECT: SMART VENT° AUTOMATIC FOUNDATION I #1540Z70; #1540-574; #1540-524; #1540-514 FLOOD VENT SEALING KIT #1540-526 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supple in ICC-ES evaluation report ESR-2074, have Applicable code editions: ■ 2017 Florida Building Code —Building ■ 2017 Florida Building Code —Residential 2.0 CONCLUSIONS VENTS: MODELS #1540-520; #1540�521; #1540-510; #1540Z11; is to indicate that Smart Vent® Automatic Foundation Flood Vents, described been evaluated for compliance with the codes noted below. The Smart Vent® Automatic Foundation Flood Vents, described in Sections 2.0 through 7.0 of the evaluation report ESR-2074, comply with the Florida Building Code —Building and the FRC, provided the design and installation are in accordance with the 2015 International Building Code® provisions noted in the evaluation report. Use of the Smart Vent® Automatic Foundation Flbod Vents has also been found to be in compliance with the High -Velocity Hurricane Zone provisions of the Florida Building Code —Building and the Florida Building Code —Residential. For products falling under Florida Rule 9N-3, verification that the report holder's quality assurance program is audited by a quality assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the ev report, reissued February 2021. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for tts use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product cover d by the report. EMIR u - co�ccaunrr Copyright© 2021 ICC Evaluation Service, LLC. All rights reservod. Page 6 of 5