ELEVATOR SPECIFACTION
2 stage DP
�11001bs
40 fpm
14'
2
2
Relay Logic,
2'
220 V.A.C., 30 amp, single phase w/neutral
f 10'
f 110 V.A.C., 15 amp, single phase
Automatic
Botton adj
47"x54"x94"ID
Optional
IEECO 5HP
Base cab is cabinet grade plywood veneer, high
hat; ceiling .fixture, stainless fixtures, vinyl woodfold
I gate, finishfloor by others.
Installation shall comply with ASCE 24-05
Pump unit electrical and .control elevated above flood level.
PALM BEACHLIFTS, JNC.
(WORK BY OTHERS)
1. Permanent power to operate the elevator must'be provided to a lockable fused disconnect..A
machine room/area is to be provided. by the owner/agent before installation begins, per Palm
Beach Lifts, Inc. specifications. If temporary power is provided to expedite the installation, it is
the owner/agent's responsibility to provide.adequate power.
Due to the desirable battery backup feature that our controllers offer, it is highly recommended
that the following disconnect, or its equal, be .used:
Siemans (or comparable quality).
SMNS 4221 N D
SMNS HA161234 auxiliary contact kit
SMNS HR21 rejection clip kit (RKS type fuse)
Without an auxiliary contact. in disconnect,, as listed above, emergency lowering voltage cannot
be removed properly when disconnect is turned off.
2. Where applicable, tow sleeves, three inches in diameter; are to be provided for the electrical,
conduit and hydraulic hose from the machine room to the hoistway. If trenching is needed this
also shall be provided by the owner/agent.
3. No conduit wiring and piping other than pe6ining to the lift equipment is permitted in the
hoistway.
4. Due to close running clearance, the`owne'rlagent must assure that the hoistway is constructed
plumb, square and true to dimension's as specified Palm Beach Lifts, Inc.
5. It is the sole responsibility of the owner/agent to provide adequate support for guide rail
fastenings and a shaft which will safely support all loads imposed by lift equipment.
6. The pit floor is to �be Provided by owner/agent-to support a load as specified by Palm Beach Lifts,
Inc.
7. Pit must be clean,. dry and level. Flit water .proofing or sump, if required, is to be provided by
owner/agent.
8. Any changes to overhead must, be approved by Palm Beach Lifts, Inc. prior to ordering
equipment.
9. Pit walls must be in line with rail and hoistway walls. Where applicable, no footing or obstruction
shall be under the cut-out areadesignated for cylinder installation.
10. Where applicable, front wall hoistway is to. be left at. the lowest level until the car enclosure is
installed. Entrance frames are to be erected after the elevator is 'installed. Finish grouting and
masonry around doors is the responsibility of the owner/agent.
11. Call buttons must be inserted in the wall. The drywall and painting after installation is the
responsibility of the owner/agent.
12. Palm Beach Lifts, Inc. highly recommends the installation of solid -core doors at each landing and
will not be responsible for doors warping and repairs caused by their warping. Door hardware is
the responsibility of the owner/agentz
13. Residential; elevator code states,the,following rules, and the layout ofIthe hoistway doors must
comply with these rules: R321
14. A telephone line shall be provided in the machine room .and located near the elevator control
panel.
Car 51zinci for 2.! Stop Elevator
Back Wall Application
Clear hoi5tway
-A-4
Car ,Frame Rai.1 -,-?y5tcm requires a
24" or deer r pit
7
-1
--Car frame - 2"
E
Clear in5ide dimension
'E
based on hoistway
3
Owerhead dimension.
Accordion gat
2" 2 minimu "min',mu
3" minimum
m
10"
10"Priihimum
3/4" -het 136ck Plate Kit
K]t Contains:
orta: M, L L.M. Door Locks
1- Plate,
1- Back Spacer
4- 114:20 Nuts 0.750. .
2- 0 32x7116" F.H. Screws
2- 10-32 Acorn Nuts
EMDL Electric Lock Sold Separately
I
i
Weld.Studs Holstway Door
1/4-20x21iZ Door Jamb T=1-314"
(4)0 I
I
�l
I
i
I
12.0
Tapped Holes_
1032
r
3.0,
Note: if MoIjstway Door is, less than 1-3W thick addiflonal W" spacers
are tegiired err Hall side of pule.. Additional spacers are -told
separately. Parf Numb6c EMDL?WSP
i
1
I
Porta.Plate
K 91
it -installation
WARNIN The installation of this dev : ice should only be performed by a professional elevator
technician that has a,full uildetstanding of this device's operation and function.
Note: if there is any doubt regarding the installation procedures, please call the
factory for assistance. We are available M-F 8:00 -am to 5*00 pm Central Time.
WARNING: Failure to. c 0.6 comply with, a nstructions and 4WARNING"(s) can result in, a safety
system compromise. This;.
in tum,� can result in serious injury or death.
Pre-Irtsta'llation-
1. Fully read and understand all instructions and . warnings.
2. This kit is to only be used with the Porta EMIJL series,
3. This kit.1s.intended for 1 'Vi"'thiql< solid core Noistway doom
1f yourdo.or. is less than I Ye' thick spacerr. must be added . to the hall side of the door to make up
the difforence. 1/8"'thilok spacers (PXEM-1 ,
t DL750SP) are.solld separately. The spacers are not
. .
handdependant. . i
4. These instructionsare to be used in:conjurIctibn with the lock installation .instructions.
Plate Kit.
Installation-
i) The: lock must be mounted on.the knob/fatth -tide- of t I he.door.
Z, D The
lock height The lock�will accepia rnufti-conductor cable from the back,or Y27 conduit from the top!
3) The lock, requires a.flat mounting surface. Re move12-5116" of, door stop trim aai-nb tide) at the desired lock locationi.
4) From inside. the hoistvv,ay, secure the template providedto the lock mounting surface and door.
5.) Drill holes "per the template instructions.
a
WARNING: DO NOt.ATTEM PT70 INSTALL PLATE KIT WITHOUT USING THE TEMPLATE.
6) Mount plate,and backing spacer to door
7) Tface,inside -line. of backing spacer to door p
0) Remove plate and backing spacer
9) Cut door along traced: outline
10) Attach Keeper to Hoistway side of plate with tuo 10-32 x 7/16" flat head screws
I 1.)'Lock Keeper in place using two 1 0-32 acorn nuts
12). Mount Plate: and backing spacer to door
11). Mount the'doorlokk to the jamb using:two #10' x I W.' pan head tctevvt
'15rdm the,*holstkay sid6,. close the door and verify .4
14) that you can release the latch manually.
6) -Adjust the lock and or kepper,as' nece at . y
*****WARNING- Do NOT MODIFY THE COVER TO ACCEPT THE KEEPER**—*
15) Refer to "Ports Electric Dodr1ock Installation" instructions items 9-16 to complete the installation
. ***WARNING***
Ail 43pections.. maintenance, repairs and replacements should be performed by elevator personnel only.
***WARNING***
Poft Inc. Phone: (847) 5934900
250 Hamilton Rd.
Fax: Arlin(047) 593A$94
ton Heights, IL 60005
website: www.emiporia.com
PALM ;BEACH LIFTS, INC.
1748..AuStralian Avenue N6rth, Suite 14
Riviera Beach, FL 33404
(561) 863-7707
Fax (561), 863-7799
Kathie@palm' beachlifts.com
I
i
MACHINE ROOM POWER REQUIREMENTS
DISCONNECT
Due to the: desirable battery'back�p feature that our controllers offer, it
is highly recommended that';the following disconnect, or its equal be
used:
Siemans. (or, comparable quality)' i
SMNS H:F221N D
SMNS HA161234. auxiliary contact. kit
SMNS HR21 rejectimn clip kit ((RKS type fuse)
Without an auxiliary contact in disconnect, as: listed above, emergency
lowering voltage cannot be .removed properly when disconnect is turned
off.
i
POWER SUPPLY i
i
3G amp service
220/240 V single phase I
Ground and. Neutral
�i
Separate 110 vac light circuit for cab lighting. (recommended)
'i
TELEPHONE
Telephone line wired to a standard female jack preferable
If phone line is not wired into -a standard female jack, wires must be
marked h
GENERAL LIGHTING
General lighting; of the machine room space with a -lighting switch made
easily accessible should be provided to aid serviceability of equipment
-in, the future
I
BUILDOUT REQUIRED WHEN MOUNTING PUMP BELOW CONTROLLER
:OFILE FRONT
A
I
—3 8-1
�2' 8V in �1
Dimain
sconnea
Controller
Phone
as
Ughdng
Disconnet
21-6"
cN
PRODUCED BY AN: AUTODESK EDUCATIONAL PRODUCT
Palm Beach Lifts
Recommended Hoistway Construction
�
(2) 2 x 10 glued and screwed, supported and
fastened between (2) 2 x 4 behind plywood
Of Pail
for supporting rall,brackets,. All suppnrt� should
brackets
be STRAPPED to slabs, Joists, and trusses.
The maximum distance between the
inside face of the hoistway door
and the hoistway sill is 3".
The maximum distance between the
Inside face of the hoistway door
and the car gate is 5".
Typical stud and wall II board construction. I�
a
I
19naO*Jd IVNO ldDnpa meauolntt N,V A8 a3DnUOM'd
Palm Beach Lifts
two stop
rail system
Fasteners to be
1 /2" x 3" sleeve
anchors in poured
block or 1 /2" x 3"
lags in wood
backing.
bracket
through bolts
�!
� _.: h" '�pRJ.°¢.AVGTM1�G�P^4. Cbc3"p'.zen.'_a=T',:Ps:6.•.
,�S.dY,lx.�
z FY��d^'C'a•:%2ki?k+3�E.....7t '^�:L' ALO.'.�'.rG.'Y'.a�.C.'�..+�Ai'93'J.'�i�8e.�'a:?
t