HomeMy WebLinkAboutSOIL NUCLEAR GAUGE 7-11-19%P
ON, F,J,--,-Xr - M_
Soil Nuclear Gauge
Report Date: 7/11/2019
Test Method: ASTM D 6938
ry RNA
Vv\ Port SL Lucia
FBPE CA # 4930
607 NW Commodity Cove
Port St'
Lucie. FL 34986
Phone: 772-924-3575 I Fax: 772-924-3580
Client:
Sion Homes Construction Corp
3831 SW 147 Ave.
Miami, FL 33185
Project:
19-4061.00
Sion Homes Construction, LLC 2019 Master
Agreement
North Palm Beach, Martin, Saint Lucie,
Indian River, Okeechobee and Brevard
Counties...
FL
Test Results
Test #
Retest
Of
Test
Date
Proctor lD
Method
Soil
Classification
Optimum
Moisture
(%)
Maximum
Dry Density
(pcf)
In Place
Moisture
%)
In Place
Dry Density
cf)
Probe
Depth
(in)
Percent
Compaction
Min/Max
Comp.
(%)
Remark
19
7/1/19
9331 D1557
N/A
10.7
112.6
7.7
109.9
12
98
951105
Pass
20
7/1/19
9331 D1557
N/A
10.7
112.6
7.9
110.8
12
98
951105
Pass
21
1
7/1119
1 9331 D1557
N/A
1 10.7
1 112.6
1 8.0
1 109.0
12
1 97
951105
Pass
Test Information
Test #
Test Location
Elevation
Reference
Gauge
Make / Model / SN / Calibrated
Field Technician
19
Below Slab Grade: Lot #1, 4410 N Highway Al A, Ft Pierce, Garage Slab, NW Corner
0-1'
Troxier / 3430 / 34151 /
Liverman, Robert
20
Below Slab Grade: Lot #1, 4410 N Highway A1A, Ft Pierce, Garage Slab, Center
0-1'
Troxier / 3430 134151 /
Liverman, Robert
21
Below Slab Grade: Lot #1, 4410 N Highway A1A, Ft Pierce, Garage Slab, SE Comer
0-1'
Troxier / 3430 / 34151 /
Liverman, Robert
Remarks I
I Comments
Pass: Tests results comply with specifications
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
'Backscalter'. Gauge calibration data on file with the testing agency.
--
.�`��pNN. KENT'%
tCENSF i
No 9A 8
Ke ; O.E. 1
Pfo slona�E�kTc�14L�er /k$$
StagtlOr1�?RID , G\
S/NAB
Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Page 1 of 1
Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.