HomeMy WebLinkAboutCONSTRUCTION SET PAGE 1-4STRUCTURAL NOTES CONSTRUCTION SET GENERAL NOTES THE DESIGN AND CONSTRUCTION OF THE STRUCTURE AND/OP STRUCTURAL COMPONENTS DEPICTED ON THIS PLAN ARE FULLY UNDER THE JURISDICTION OF THE FLORIDA BUILDING CODE 2017, 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS WITH THE ARCHITECTURAL PLANS PRIOR TO COMMENCEMENT OF CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT FOR COORDINATION OF CHANGES WITH THE ENGINEERING PLANS AND SPECIFICATIONS. 3. CONTRACTOR SHALL COORDINATE SLAB ELEVATION, CHANGES, DEPRESSIONS, THRESHOLDS, PADS, ETC. AND ANY UNKOWN FIELD CONDITIONS. 4. THE CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS IN THE FIELD PRIOR TO FABRICATION AND START OF CONSTRUCTION AND TO PROTECT AND MAINTAIN ALL THE CONSTRUCTION AND ITS CONTENTS. 5. REFER TO THE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS NOT INDICATED. ANY DIMENSIONAL DISCREPANCY FOUND ON THE STRUCTURAL DRAWINGS SHALL BE FURTHER VERIFIED WITH ARCHITECT * ENGINEER. G. FOR MOUNTING AND SECURING MECHANICAL EQUIPMENT, REFER TO THE MANUFACTURES NSTRUCTIONS UNLESS INDICATED ELSEWHERE IN THE CONSTRUCTION DOCUMENTS. 7. THE GENERAL CONTRACTOR SHALL AT ALL TIMES MAINTAIN AT THE JOB -SITE, A CURRENT APPROVED SET OF SHOP DRAWINGS. 8. REFER TO ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR OPENINGS, SLEEVES, ETC, NOT SHOWN ON THE STRUCTURAL DRAWINGS, 9, ALL CONSTRUCTION PERFORMED IN ACCORDANCE WITH THESE PLANS MUST AL50 MEET OR EXCEED ALL APPLICABLE AND CURRENT BUILDING CODE REQUIREMNTS AND MUST BE PERFORMED IN ACCORDANCE WITH FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION CCCL PERMIT. 10. AT ALL PHASES OF CONSTRUCTION, IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO CONFIRM THAT ALL PROPOSED CONSTRUCTION IS IN ACCORDANCE WITH THE MOST UP-TO-DATE CONSTRUCTION DRAWINGS AS APPROVED BY THE ARCHITECT AND ENGINEER OF RECORD. 1 1. THE WALLS AND PARTITIONS BELOW THE DE51GN FLOOD ELEVATION HAVE BEEN DESIGNED TO COLLAPSE FROM A WATER LOAD LF55 THAN THAT WHICH WOULD OCCUR DURING THE BASE FLOOD. 12, THE ELEVATED PORTION OF THE BUILDING AND SUPPORTING FOUNDATION SYSTEM HAVE BEEN DESIGNED TO WITHSTAND THE EFFECTS OF WIND AND FLOOD LOADS ACTING SIMULTANEOU5LY ON STRUCTURAL AND NONSTRUCTURAL BUILDING COMPONENTS. FOUNDATION NOTES FOUNDATIONS SHALL BE PREPARED IN FULL CONFORMANCE WITH THE GEOTECHNICAL ENGINEERING REPORT. 2. ALL RECESSES IN CONCRETE SLAB TO BE COORDINATED WITH ARCHITECT FOR DETAILS INCLUDING BUT NOT LIMITED TO: THRESHOLDS, STEPS, RECESSED SHOWER LOCATIONS, FLOORING FINISH MATERIALS, AND DRAIN LOCATIONS, ETC. 3. A VAPOR BARRIER 15 TO TO BE PLACED UNDER ALL BUILDING FOUNDATION BEAMS AND FLOOR SLABS IN ACCORDANCE WITH A5TM E 1 993-98. TO BE INSTALLED PRIOR TO POURING CONCRETE FOR FOUNDATION. 4. ALL ELECTRICAL CONDUIT, PLUMBING, A/C DUCTS, AND OTHER MECHANICALLY REQUIRED INTERIOUR COMPONENT LOCATIONS AND INSTALLATION MUST BE COORDINATED WITH THE ARCHTECT PRIOR TO CONSTRUCTION OF THE FOUNDATION. 5. CONTRACTOR SHALL COORDINATE SLAB ELEVATIONS CHANGES AND ANY UNKNOWN FIELD CONDITIONS. G. THE FOLLOWING FREQUENCY OF TESTING SHALL BE REQUIRED BEFORE PLACING CONCRPTE FOR FOOTINGS AND SLABS: CONTINUOUS FOOTING/GRADE BEAM SHALL BE TESTED EVERY 40 LINEAR FEET AT BEARING ELEVATION AND ONE FOOT BELOW BEARING. COLUMN FOOTINGS - 25% OF FOOTINGS SHALL BE TESTED AT BEARING AND ONE FOOT BELOW BEARING. BUILDING PAD SHALL BE TESTED EVERY 1000 SQUARE FEET OF FLOOR AT GRADE AND ONE FOOT BELOW GRADE. IN AREAS OF THE BUILDING PAD WHERE 501L 15 BEING CUT IT IS THE RESPONSIBILITY OF THE SITE CONTRACTOR TO DEN5IFY THE TOP 12 INCHES OF EXISTING 501L TO 95% OR MODIFIED PROCTOR AS RECOMMENDED IN THE SOILS REPORT FOR THI5 PROJECT PREPARED BY K5M ENGINEERING, INC. DATED NOVEMBER 2009. CONCRETE REINF RMCEMENT I . CONCRETE REINFORCING BARS 5 ALL BE DEFORMED NEW BILLET STEEL CONFORMING TO A5TM A-6 15, GRADE GO, WITH MINIMU v1 YIELD STRENGTH = 60,000 psi. 2. REINFORCEMENT FOR CONTINUO 5 FOOTINGS SHALL BE CONTINUOUS AND SPLICED WITH A FULL 24 INCH LAP. PROVIDE CORNER BAR 3 3. ALL CONCRETE MA50NAPY CONS TPUCTION SHALL CONFORM WITH ACI 530-88/ASCE 5-88. ALL CONCRETE MASONRY UNITS 5HA L COMPLY WITH ASTM C-00 WITH TYPE M OR MORTAR COMPLYING TO A5TM C-270. MA 50NRY UNITS SHALL HAVE A MINIMUM COMPRE551VE STRENGTH OF 2000 PSI ON THE NET AREA. 4. ALL SPLICES SHALL BE LAP SPUCI 5, SHALL BE A MINIMUM OF 48 BAR DIAMETERS, U51NG LARGER BAR DIAMETER WHEN SPLICING D FFERENT SIZE BARS.REINFOPCEMENT TERMINATIONS INTO TIE BEAMS AND FOUNDATIONS OR A 5 NOTED. 5. REINFORMCEMNT MAY BE BENT SHOP OR FIELD, PROVIDED THAT THE DIAMTERE OF BEND SHALL BE GREATER THAN 6 BAR DIAMET RS. REINFORCEMENT PARTIALLY EMBEDED IN CONCRETE SHALL NOT BE BENT. G. SECURE PREINFORMCEMNT FROM I5PLACEMENT DURING PLACEMEMNT UTILIZING CHAIRS AND BOLSTERS. WELDED WIRE MESH E HALL CONFORM TO A5TM A- 185. PROVIDE CHAIRS AND BOLSTERS TO INSURE THAT THE MESH 15 EMBEDDED I " FROM TOP OF SLAB. 7. STANDARD 90 DEGREE HOOK (ST NDAKD HOOK) SHALL TERMINATE WITH A 90 DEGREE BEND AND AN EXTENSION FROM BEND AT LEAST 12 BAR DIAMETERS. THI5 SHALL BE USED AT ALL VERTICAL REINFORCEMENT TERMINATIONS I TO TIE BEAMS AND FOUNDATIONS OR AS NOTED. 8. MINIMUM CONCRETE COVER SHA L BE: FOOTINGS * PILES BEAMS, SLABS, WALL 2" GROUTED MASONRY " 9. ALL PILE VERTICAL REINFOPCEME T SHALL BE SHOP FABRICATED WITH CLEAN 500 BENDS INTO TRANSITION CAPS. HOOK5 SHAL HAVE A MINIMUM LEG DIMENSION OF 1511 AND SHALL BE TURNED ACROOS PILE INTO CAP CENTER ( AINTAIN A MINIMUM 3" CONCRETE COVER). 10. ALL BEAM STEEL SPLICES SHALL CCUR AT MID5PAN POP TOP STEEL AND OVER COLUMNS FOR BOTTOM STEEL. CONCRETE NOTE I . ALL CONCRETE DESIGN AND PLAC MENT SHALL BE IN STRICT ACCORDANCE WITH THE ACI "BUILDING CODE REQUIREMENTS FOR 5TPUCTUPAL CONCRETE," ACI 3 1 8-55. 2. CONTACT ENGINEER 48 HOURS PRIOR TO POURING CONCRETE 50 ARRANGEMENTS CAN BE MADE TO HAVE AN ENGINEER OR IN5PEC OR PRESENT DURING THE POUR. 3. PROVIDE (4) TEST CYLINDERS FOR EACH 50 C.Y. OF CONCRETE PLACED OR FRACTION THEREOF. 4. STRUCTURAL CONCRETE SHALL CONFORM TO ACI 301 SPECIFICATIONS AND SHALL DEVELOP THE FOLLOWING MINIMUM COMPRE551 E STRENGTH AT 28 DAYS: SPREAD AND WALL FOOTINGS 3000 PSI COLUMNS AND WALLS 3000 PSI BEAMS AND SLABS 3000 PSI USE REGULAR WEIGHT CONCRETE. 5. STRUCTURAL CONCRETE SHALL CC NFORM TO ACI 301 AND HAVE THE FOLLOWING SLUMPS AGGREGATE REQUIREMENTS: LOCATION SLUMT MAX. AGGREGATE FOOTINGS 4"± -1' ASTM #57 COLUMNS 5" t 1 " ASTM #57 BEAMS AND SLABS 5"± 1 " ASTM #57 FILLED CELLS 811t 1" A5TM #8 PEAROCK TIE BMS * TIE COIL'S 5"+ 1 " A5TM #8 PEAROCK PILES 8111y1" ASTM #8 PEAROCK THE USE OF JITTERBUGS TO CONE OUDATE CONCRETE WILL NOT BE PERMITTED. THESE SOIL TESTS SHALL MEET OR EXCEED 05% MODIFIED PROCTOR (ASTM D 1 557 METHOD A) G. ALL PUMPED CONCRETE WITH #57 AGGREGATE IS TO CONTAIN A HIGH RANGE WATER REDUCING 7. THIS STRUCTURE 15 DESIGNED IN ACCORDANCE WITH ASCE 24. THE PILE * COLUMN FOUNDATION AGENT. MINIMUM 51ZE OF D15CMA RGE TO BE 4" I.D. AND THE STRUCTURE TO BE ATTACHED THERETO HAVE BEEN DE5IGNED TO BE ANCHORED TO RE51ST FLOTATION, COLLAPSE AND LATERAL MOVEMENT DUE TO THE EFFECTS OF WIND AND FLOOD LOADS 7 A 2" I.D. DISCHARGE MAY BE U5EE WITH #8 AGGREGATE. USE PLASTICIZER ADMIXTURE IF ACTING SIMULTANEOUSLY ON ALL BUILDING COMPONENTS, IN ADDITION TO OTHER LOAD NECESSARY TO INCREASE SLUMPS BEYOND THAT NOTED ABOVE. REQUIREMENTS AS DEFINED IN CHAPTER 16 OF THE FBC. 8. CHAMFER ALL EDGES OF EXPOSED CONCRETE 3/4" UNLESS NOTED OTHERWISE. DEEP FOUNDATION 9. ALL SLABS ON GRADE SHALL BE FI WELDED WIRE ER REINFORCED CONCRETE, UNLESS NOTED OTHERWISE. FABRIC SMALL CONFORM TOA5TM-A185, PILES SHALL BE CAST IN PLACE (AUGER) 16" DIA with 5,000 psi CONCRETE (SEE TYPICAL DETAIL). 0. SLEEVE ALL PENETRATIONS THROU PERMITTED. SUBMIT LOCATION AND H BEAMS AND SLABS INDIVIDUALLY. CORE DRILLING WILL NOT BE SIZE OF SLEEVES THROUGH BEAMS TO ENGINEER FOR REVIEW 2. ALL PILES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE SOILS PRIOR TO CASTING CONCRETE. ENGINEER AND PROVIDE THE FOLLOWING CAPACITIES: 1 1. NO REINFORCING BARS SHALL BE UT TO ACCOMMODATE THE INSTALLATION OF ANCHORS, EMBEDS all piles @ 20't below scour - 40 TONS COMPRESSION; 12 TONS TENSION OR OTHER ITEMS, REFER TO PILE SCHEDULE (sheet 5-2) FOR MORE DETAILS. 12. AT CHANGES IN DIRECTION OF CO BARS OF SAME SIZE AND QUANTI CRETE WALLS, BEAMS * STRIP FOOTINGS, PROVIDE CORNER UNLESS NOTED OTHERWISE AS HORIZONTAL STEEL, REFER TO TYPICAL DETAIL. 3. UNLESS OTHERWISE NOTED ON PLANS, CENTER ALL PILES/PILE CAPS UNDER RESPECTIVE COLUMNS. 4. CAST IN PLACE (AUGER) TYPE PILES SHALL CONSIST OF CONCRETE PLACED AFTER BEING DRILLED BY 3. ALL EMBEDDED ITEMS SHALL BE S CUPELY TIED IN PLACE PRIOR TO CONCRETE PLACEMENT. A CONTINUOUS FLIGHT AUGER. 14. WEDGE BOLTS SHALL BE ITW RAM-SET/REDHEAD BOLTS OR APPROVED EQUIVALENT INSTALLED IN TOLERANCE FOR PILES IS 2" IN ANY DIRECTION UNLESS NOTED OTHERWISE. ALL PILES TO PENETRATE ACCORDANCE WITH MANUFACTURERS INSTALL. RECOMMENDATIONS. DO NOT CUT EXISTING REINFORCING TO (-) 20.00 NAVD OR A5 NOTED. REFER TO PILE SCHEDULE (sheet 5-2) FOR MORE DETAILS:. 15. HEADED STUD ANCHORS SHALL BE A5TM A 108, GRADE 5, 10 10 THROUGH 1 020 AS 5LIALLOW FOUNDATION5 MANUFACTURED BY NELSON STUD "5TRUCTURALWELDING DR APPROVED EQUIVALENT. STUD WELDING SHALL CONFORM TO AW5D1.1 ODE." 501L TO BE STRIPPED, COMPACTED AND TESTED IN ACCORDANCE WITH THE RECOMMENDATIONS 16. FOOTING SIZES SHOWN ARE FOR FOOTINGS CONSTRUCTED WITH 51DE FORMS. IF SOIL MATERIAL OF THE SOILS ENGINEER AND PROJECT SPECIFICATIONS. CAN HOLD A VERTICAL SHAPE, IT C N BE USED AS AN EARTH FORM. ALL SLOUGHED MATERIAL SHALL BE REMOVED FROM EXCAVATION BEFORE AND DURING PLACEMENT OF CONCRETE. 2. CENTER ALL FOOTINGS UNDER THEIR RESPECTIVE COLUMNS OR WALLS UNLESS OTHERWISE SHOWN ON PLANS. MAXIMUM MISPLACEMENT OR ECCENTRICITY SHALL BE 211. TOLERANCE FOR 17. PLACEMENT OF CONDUIT AND PIPE3 IN CONCRETE SHALL CONFORM TO ACI 3 18, SECTION 6.3. MISLOCATION OF COLUMN DOWELS OR ANCHOR BOLTS TO BE PER ACI OR AI5C STANDARDS. 3. WHERE VERTICAL CONSTRUCTION JOINTS OCCUR IN CONTINUOUS FOOTINGS, PROVIDE A KEYWAY PER THE TYPICAL DETAIL. HORIZONTAL JOINTS IN FOOTINGS WILL NOT BE PERMITTED. 4. CONTRACTOR TO NOTIFY ARCHITECT/ENGINEER IF SOIL CONDITIONS ARE UNCOVERED THAT PREVENT THESE PLANS ARE NOT FOR CONSTRUCTION UNLESS STAMPED THE REQUIRED SOIL BEARING PRESSURE FROM BEING OBTAINED. „ „ Construction Set , DATED SIGNED AND SEALED BY THE ENGINEER. 5. COORDINATE PLUMBING LINES WITH FOOTING LOCATIONS FOR INTERFERENCE. INDIVIDUAL ALL CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL FOOTINGS SHOULD 13E LOWERED WITH THE PRIOR APPROVAL OF THE 5TP.UCTURALENGINEER. JURISDICTIONAL PERMITS, ONDITIONS AND CONTRACT DOCUMENTS. CONTINUOUS WALL FOOTINGS SHOULD BE STEPPED AS DETAILED ON THE DRAWINGS. G. EXCAVATING UNDER OR NEAR IN -PLACE FOOTINGS/FOUNDATIONS WHICH DISTURBS THE COMPACTED SOIL BENEATH THE FOOTINGS/FOUNDATIONS WILL NOT BE PERMIT$�D. CONTRACTOR SHALLCOORDINATE ALL DETAILS AND 7. REINFORCING SHALL BE SUPPORTED ON PPECAST CONCRETE PADS, DOWELS FOR COLUMNS AND ELEVATIONS WITH AR H ITECT PRIOR TO CONSTRUCTION FILLED CELLS SHALL BE SECURED IN PLACE PRIOR TO POURING CONCRETE. USE TEMPLATES FOR SETTING COLUMN DOWELS AND ANCHOR BOLTS, P17 P 17a P18 P30 P21 P24 P32 P3 /bP 14 P15 P20 P25 P33 KIM P13 PILING OVERVIEW SCALE: 3/ 1 01 = I '-011 CODE * DE51GN CRITERIA I . ALL STRUCTURAL PLANS SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE AND FLORIDA BUILDING CODE RESIDENTIAL 2017. 2, BUILDING CLASSIFICATION ENCLOSED 3. DE51GN WIND SPEED 170mph Vult 4. IMPORTANCE FACTOR 1.0 5. EXPOSURE CLASSIFICATION D 6, INTERNAL PRESSURE COEF. t 0. 18 7. 51ESMIC ZONE 0 8. MEAN BUILDING HEIGHT 28.42' 9. ALLOWABLE SOIL BEARING PRE55URE 2,500 P5F. VERIFY WITH GEOTECHNICAL ENGINEER REPORT PRIOR TO CONSTRUCTION. ASSUMPTIONS: A. THE BUILDING IS "ENCLOSED" AS DEFINED IN "FLORIDA BUILDING CODE 201 7. B. WIND VELOCITY PRESSURES AND COEFFICIENTS USED ARE FOP MAIN WIND FORCE RESISTING SYSTEM; ALLOWABLE STRESS DESIGN, Kci = 0.85. C. ALL PRE -MANUFACTURED COMPONENTS, I.E. WINDOWS, DOORS, JAMBS, TRUSSES ETC. SHALL BE VERIFIED BY MANUFACTURER TO BE CAPABLE OF SUSTAINING DESIGN WIND FORCES. INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS. D. ALL COMPONENTS AND CLADDING SUBJECT TO WIND LOADINGS: I.E. ROOF TILES, SOFFITS, ETC. SHALL BE INSTALLED IN ACCORDANOE WITH MANUFACTURERS SPECIFICATIONS FOR ADEQUATELY RESISTING ORTPAN5FERPING WIND LOADS TO THE MAIN WIND FORGE RESISTING SYSTEM. E. OWNER OR CONTRACTOR SHALL OBTAIN NECESSARY INSTALLATION SPECIFICATIONS AND INSPECTIONS REQUIRED TO COMPLY WITH MANUFACTURERS PECCOMMENDATIONS FOR INSTALLATION OF COMPONENTS AND CLADDING FOR HIGH WIND VELOCITY AREA5. 5 PII P12 P34 P35 m P7 P4 0 P48 P4 I JUN 18 2019 ST. Lucie County, permitting s ue P39 t U o U N Ell w za 3� W v F" ° x o Ua�"W 5Q�" �Q' z �z Ea WZ w O \.J W C:) Q `x 0�° �U �U�z a x z REFER TO SHEET 5-2 FOR PILING SCHEDULE, REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNT MA50NRY NOTE5 BOCC I . MASONRY CONSTRUCTION SHALL CONFORM TO ACI "BUILDING CODE EQUIREMENT5 FOR MASONRY > rJ] STRUCTURES" (ACl/ASCE 530-88) AND SPECIFICATIONS FOR MASONRY STRUCTURES" (ACl/ASCE � 530. 1 -88) EXCEPT AS AMENDED BELOW. 2. STRUCTURE HAS BEEN DE5IGNED AS A BEARING WALL STRUCTURE. ALL MASONRY UNITS SHALL BE LAID PRIOR TO CONCRETE PLACEMENT OF COLUMNS, BEAMS AND SLABS FOR THE SAME STORY. 3. USE TYPE "M" MORTAR WITH MINIMUM COMPPE551VE STRENGTH OF 2500 PSI FOR ABOVE GRADE APPLICATIONS AND TYPE "5" MORTAR WITH A MINIMUM COMPRESSIVE STRENGTH OF 2000 P51 FOP r�- BELOW GRADE APPLICATIONS. 4. MASONRY UNITS SHALL CONFORM TO ASTM C90 WITH A -MINIMUM COMPRE551VE STRE F h�l 2800 PSI ON NET SECTION, TO PROVIDE NET AREA COMPRESSIVE STRENGTH OF MASO �'' 2000 PSI, 5. PROVIDE FILLED CELLS AS SHOWN ON PLANS. IN ADDITION. PROVIDE FILLED CELLS: a=-t W A. AT ANCHORAGE OF CONNECTIONS OR BEARING OF BEAMS AND GIRDER TRUSSES B. AT ALL CORNERS AND INTERSECTIONS C. ( I ) CELL ADJACENT TO OPENINGS FOR WALL SPANS LE55THAN 10'. (2) CELLS ADJA TO OPENINGS FOR WALL SPANS GREATER THAN 10' W Q O D. AS SHOWN ON ARCHITECTURAL PLANS G"5� 1 w E. MAXIMUM 48" O.C. (UNLESS NOTED OTHERWISE) G. PROVIDE FULL MORTAR BEDDING AROUND ALL FILLED CELLS WITH VERTICAL REINFORCIN O 2 7. REINFORCING FOR FILLED CELLS SHALL CONFORM TO A5TM AG 15, GRADE GO. LAPPED DIAMETERS. O V U 8. ALL FILLED CELLS AND COLUMNS SHALL BE POURED AT LEAST TWO (2) HOURS PRIOR TO POURING M« i O U BEAMS AND LINTELS. Y--I 9. REINFORCE WALL WITH LADDER TYPE REINFORCEMENT ("DUR-O-WALL" OR EQUAL) IN BED JOINTS AT I G" Q.C. MEASURED VERTICALLY. LAP SPLICE ALL HORIZONTAL WALL REINFORCING 6". PROVIDE PREFABRICATED "TEE" OR CORNER SECTIONS AT ALL INTERSECTING WALL5. PROJECT No. 10. REFER TO TYPICAL WALL SECTIONS FOR MAXIMUM CONSTRUCTION HEIGHT OF MASONRY WALL5. PROVIDE CLEAN -OUT HOLES AT BASE OF FILLED CELL WHEN THE CONCRETE POUR EXCEEDS 18-022 5 FEET IN HEIGHT. SHEET 1 1. ALL FRANGIBLE (BREAKAWAY) WALLS HAVE BEEN DESIGNED IN ACCORDANCE WITH A5CE 24, S MIN I= ^^rI 1 I r. P9 P17 P 17a P2 I TYPICAL FILING f -TRAN5ITION CAP CRITICAL BEARING PILING 52.5 kips COMPRE55oN LOAD TYPICAL FILING A P 1 V ARWALL FOOTING A TYPICAL FILING T P 2 2 TRANSITION CAF P3 AP4 AP5 P14 P15 TYPICAL PILING @ GARA( on 5HEARWALL FOOTING 35 kips TYPICAL LOADIN( TYPICAL PI ING TRANSITION CAP @ GARAGE 6' P13 CRITICAL BEARING PILING 57.5 kips COMPRESSION LOAD PII P12 TYPICAL PILING # TRANSITION CAP @ GARAGE _ __m... -_ _ ,_...... - 02 P3 7 .P20 \ I P 2 4 5HE RWA�� FOOT P 2 5 43 kips MAX. LOADING TYPICAL PILING T TPAN51TION CAF vote] ELEVATION CHANGE AT 5NEARWALL PILING P32 TYPICAL PILING @ 5HEARWALL FOOTING 42.3 kips MAX. LOADING 10 G AUGER -CAST PILE SCALE: 1 /4" = I-0" C ITICAL BEARING PILING 5 3.4 kips COMPRE CAD j TYPICAL PILING @ ELEVATOR PI - REFE TO DETAIL 511ET 5- P33 LAYOUT THESE PLANS ARE NOT FOR CONSTRUCTION UNLESS STAMPED "Construction Set", DATED, SIGNED AND SEALED BY THE ENGINEER. ALL CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL JURISDICTIONAL PERMITS, CONDITIONS AND CONTRACT DOCUMENTS. CONTRACTOR SHALL COORDINATE ALL DETAILS AND c l ELEVATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION. a VATION CHANGE 5HEARWALL PILING CONSTRU'TION SET in• P7 TYPICAL PILING @ GARAGE- PI0 v U DOUBLE PILE @ SHEARWALL FOOTING ITICAL BEARING POINT F A P43 TYPICAL PILING # TRANSITION CAP P3 5 9'- 10"- i� P48 1-7 ---, P47 { TYPICAL PILING @ PATIO w/ TRANSITION CAP • P42 P39 POURED -IN -PLACE or N PILATER BLOCK CONCRETE COLUMN - REFER TO PLANS FOR LOCATIONS - REFER TO COLUMN SCHEDULE FOR N SPECIFICATIONS REINFORCEMENT - TYPE "C- I " COLUMN ILLUSTRATED N TRANSITION CAP or GRADE BEAM REFER TO TRANSITION CAP DETAIL (sheet 5-3) FOR REINF, REFER TO GRADE BEAM DETAILS 5heet 5-9 -- CLEAN OUT G" BELOW TOP OF PILE PRIOR TO CAP CONSTRUCTION #3 STIRRUPS SPACED 3" O.C. 9 @ TOP OF PILE THEN 10" O.C. FOR REMAINDER AS SHOWN m I G" cha. AUGER CAST - PILE w/ (G) #G BARS only (3) bars Shown PILE SHALL BE DRILLED w/ A CONTINUOUS FLIGHT AUGER AND CAST w/ 5,000 P51 GROUT .WIRE TIES I (G) #3 BARS TAPERED TO POINT * TIED TO PILE CAGE AS SHOWN wlTICAL RAN51TIING ON q PATIO PILING 5 C I G" HOOK ALL PILE REINF TOWARDS CENTER OF TRANSITION CAP or ZGRADE BEAM - REFER TO DETAIL5 (sheet 5-3) TOP OF TRAN5. CAP EL.=SEE 5CI-1EDULE v N 3" MIN, PILE EMBEDMENT per FPC 181 0.3. 1 1 PILE CAPACITY IS RELATIVE TO PILE DEPTH BELOW THE SCOUR LINE, REFER TO DEEP FOUNDATION NOTES FOR DETAILS. BOTTOM OF PILE CAGE EL.=SEE 5CI1EDULE PILE/CAP/COLUMN DETAIL SCALE: NOT TO SCALE HEDULE � a N NIMI0 o a o b+ o U ct V1 PROJECT N ,8-022 SHEET R e INSTALLATION NOTE: TOP OF PILE STEEL SHALL NOT EXCEED 3" (0.25 feet) BELOW T0Ii00V=6ApE1ANc„ S-L BOCC DESIGNATION TYPE TOP OF PILE PILE DEPTH PILE length CAP eleatlon P I -P6 16" AUGER -CAST 7.25 navd - 1 9.00 navd 26.25' 9.00 navd ............. P7-P 12 1 G" AUGER -CAST 7.25 navd - 19.00 navd 26.25' I 9.00 navd - - - _ _ -_ P 1 3-P 14 1 G" AUGER -CAST 7.25 navd 24 00 navd 3 1 .25' 9.00 navd .. ___ _ -__ . ------ -_.. ------- .._ _.-.. P 15-P 19 -1 6" AUGER -CAST 1 8.75 navd 19.00 navd 27.75' 1 10.50 navd 1 13.00 navd P20-P28 I G" AUGER -CAST ' 1 125 navd I -1 9 00 navd 34.00' 1 3.00 navd ------ __. _- -__.- r ___ _. _. ___ __ _ - P29 1 I G" AUGER -CAST I 1 1 .25 navd 24 00 navd 35.25' 13.00 navd P30 I G" AUGER -CAST 9.75 navd - 1 9.00 navd 28.75' 1 1.50 navd _-------------___ m:____. -_--____-- _ ---____. P3 1 1 G" AUGER -CAST 8.25 navd 19.00 navd 27.25' 10.00 navd .____--------- -___F -- _..._ _ __... P32 I I G" AUGER CAST 9.75 navd I 19.00 navd 28.75' 1 1.50 navd i____-_._ ..._ P33 16" AUGER-CAST�9.75 navd I 19.00 navd 28.75' 1 1.50 navd P34 I G" AUGER -CAST 1 1 .25 navd ' 19. 00 navd 30.25' 13.00 navd --------------_._.._...C_ ...- _ _.._............ P35 16" AUGER -CAST 1 1 .25 navd -1 9.00 navd 30.25' 1 3.00navd - - -- - .. -- -- -- - -------------- P36 P37 I G" AUGER -CAST 9.75 navd 1 9 00 navd 28.75' 1 1 1.50 navd _.___-___-_ _----.-------__ ---- _-- -.-_ _. P38 P49 I G" AUGER -CAST 8.75 navd 19.00 navd 27.75' 10.50 navd CONTRACTOR SHALL COORDINATE ALL DETAILS AND ELEVATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION. TOP OF BE 0 9.0 NAVD IN _ __-_ __ O I - I F-7 �SHEARWALL FOOTER 1 j (typ.) refer to details I i I 1 I i , + SLOPE 2" I typ saw ut c 1 n F_6 OP OF CAP , t 9.0 NAVD J4 1i I�- MONO ' ) (typical)/ RECES FOR GARAGE 00R s I� (typ.) - refer to details 4" THICK **FRANGIBLE** CONCRETE SLAB I v (MINIMUM 3000 PSI ® 28 DAY j N FIBERMESH REINFORCED - SAW CUT A SHOWN I I'' OVER 6 MIL. VISQUEEN VAPOR BARRIER OVER CLEAN COMPACTED TERMITE TREATED FILL (COMPACTED TO 95% DENSI Y) typical for all GROUND FLOOR sl as I a ELEVATION TOP OF CAP (9.2 N.A.V,D.) 9.0 NAVD 10" a'- 2'-0^ L 4'-7" 2' (typical) MONOLITHIC FOOTER typ,) efer to ddetails - A STEEL DISCONTINUO S AT �� TRANSITION CAPSF?, TOP OF BEAM ® 9.0 NAVD �SHEARWALL FOOTER (typ.) refer to details CONCRETE SLAB o ` 0' 1 r-B F F ® 13.0 NAVD — -I ..F, GO mi- ......... ._ > 'I' i_ ___ ___. ._�__.. _�F. saw Gut ... .. ..... 4m o A 4" AV D.) �P. saw cut pE p U IL U -0 k 10— = TOP OF BEAM q O O F-5 I j ® 13.0 NAVD -- _. typical (3 516e5 I P-3 ` MONOLITHIC FOOTER O-9refer to details sheet -�- ALL SETAINSNNCAPSATRIO t -77 - D - —.- 1.fw_... ...L_ .w ZE O TOP OF BEAM ` T0I�-- —------------- ( 013.0NAVE OF BEAM , r 0 13.0 NAVD SHEARWALL FOOTER ft ) (I ALL ENCLOSED SPACES BELOW THE BASE FLOOD ELEVATION SHALL BE PROPERLY VENTED IN ACCORDANCE WITH `BC REGULATIONS - USE CAST-CRETE 8U6 PRECAST CONCRETE LINTELS (or equivalent) ABOVE ALL REQUIRED FLOOD VENTS IN MASONRY WALL APPLICATIONS - REFER TO ARCHITECTURAL DRAWINGS FOR VENT LOCATIONS ALL CONCRETE SLABS BELOW THE LOWEST HORIZONTAL SUPPORTING MEMBER ELEVATION (16.41 N.A.V.D.) SHALL BE FRANGILBE DESIGN. refer to EXTERIOR STEPS FOUNDATION PLAN sheet S-11 TOP OF CAP 0 12.5 NAVD (typical) 2" THICKENED EDGE w/ (2) #5'5 Cont. (typ. at I under -patio slab perimeter) O F-3 refer to details I I F-3 4' THIC ONCRETE SLAB 12" THICKENED EDGE w/ F-2 A FRANGIBLE) n (2) #5'5 Cont. (typ. at 4' THICK * ELEVATION FRANGIBLE CONCRETE SLAB Saw cut ®® F n N under -patio 51ab perimeter) (MINIMUM 3000 PSI ® 28 DAYS) 5 v,D.) .w� - w. I FIBERMESH REINFORCED -SAW CUT AS SHOWN 60 � s' — t TOP OF CAP I OVER 6 MIL. VISQUEEN VAPOR BARRIER 0 12.5 NAVD i I OVER CLEAN COMPACTED TERMITE TREATED I +I . ----�----------- _ 02 = N FILL (COMPACTED TO 95% DENSITY)\ T P OF CAP �" N a typical for all GROUND FLOOR slabs / T. �� 4" thick FRANGIBLE SLAB ® 11.5 NAVD - I 1 (A/C equipment ad -refer to kU— (13.040'-0" - m I ? 1 - - - y-10" - - 2 0� Fran ,b1e 9 b21 architecturals fad I ELEVATION ���--- �--- i � _ IOP -I I'-01, B.F.F. e... — J ELEVATION N.A.V.D.) SHEARWALL FOOTER (typ.) j 6 -- ----- ------ - (125N.A.V.D.) 8refer to details P-7 Similar F- TOP OF BEAM — — — — — — — --- -- I 012.5NAVD TOfp OF BEAM ® P.O NAVD __` _. ._.. _..._.._ ... N is ) GRADE BEAM rRANSIr1oN TOP OF BEAM ® 11.5 NAVD TOP OF BEAM CONTRACTOR 5HALL COORDINATE wi'RWALL FOOTER ALL CONCRETE SLABS BELOW THE Pe`T�`ca z> ocarloN°s 013.0 NAVD ° OF BEAM ARCHITECT EA/C SUD-CONTRACTOR t refer to details �'i VD TO ENSURE ADEQUATE CLEARANCES LOWEST HORIZONTAL SUPPORTING EORACEQUIPMENrIMANENNCE MEMBER ELEVATION (16.41 N.A.V.D.)0,d,• SHALL BE FRANGILBE DESIGN. I I E AW-CUT 4" TRAN5ITION CAP LAYOUT 4" THICK CONCRETE SLABirduaede°rgakFFlANGIBLE EOOTING5 * SLABS Q fit--induced d A (MINIMUM 3000 PSI ® 28 DAYS) " mox.r=fl. FIBERMESH REINFORCED - SAW CUT AS SHOWN OVER 6 MIL. VISQUEEN VAPOR BARRIER 60° OVER CLEAN COMPACTED TERMITE TREATED :I - 1 /'�/,,/������� FILL (COMPACTED TO 95% DENSITY) -qW-CUT` - - - - - - typical for all GROUND FLOOR slabs ( { t # SCALE: 1 /41' = I '-O" THESE PLANS ARE NOT FOR CONSTRUCTION UNLESS STAMPED fKAN G I BLE HAD DETAIL "Construction Set", DATED, SIGNED AND SEALED BY THE ENGINEER. ')CALE: not to scale ALL CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL JURISDICTIONAL PERMITS, CONDITIONS AND CONTRACT DOCUMENTS. CONSTRUCTION SET DISCONTINUE STEEL for FRANGIBLE FOOTINGS refer to plans for locations 9NPo Ydt1 N:fl Yd. :IY: IINtI #3 STIRRUPS MFR'd w/ 9Ya" INSIDE DIA. �IN AUGER CAST PILE exterior edge � r — interior edge CONTINUOUS FOOTER @ ( ��"r EXTERIOR PERIMETER 6" AUGER CAST PILE w/ (2) #5'5 cont. (TYP.) J PILE CAP see detail TYPICAL PILE @ TRANSITION CAP (w/ adjacent continuous footing) #3 STIRRUPS MFR'd w/ %4' INSIDE DIA. exterior edge of grade. beam (6) #GO IN AUGER CAST FILE I 1 nterior edge of grade beam 16" AUGER CAST FILE—: TYPICAL PILE @ GRADE BEAM #3 STIRRUPS MFR'd w/ 5Y4" IN51DE DIA. exterior edge of grade beam interior edge of grade beam 16" AUGER CAST PILE (G) #GO IN AUGER CAST PILE TYPICAL PILE @ GRADE BEAM (CORNER) a 00 o I I 00 m i N I N 0 v J "J O � v m M Z W 9 N V) m Q S w U w z V)) m w E rn o d � a � w M� W O � U B 0 w 5 w o_ Y a o 0 0 !2o j I � V) f N N o a o 0 0 w ZZ w Z 3 U wJ W K 2 U Q O O U N O zU o W M m xo Us U a, w 0Q�a z � a S? N W o r r•� w V a w 0 W Z � F � N w xoCvU �j � ax. TYPICAL #6 1N AUGER CAST PILE p XIS , . top of plie bottom of tran5ltion cap p W o a it +9 a a ° .:I 6" AUGER ro 20 73 CAST PILE 71 ---16 TYPICAL PILE PROFILE a PILE REINFORCEMENT DETAILS .o SCALE: NOT TO SCALE rid r (7) #Gx 16" @ 9" a p O.C. AS SHOWN (3) #3 STIRRUPS @ E) O.C. ,.,f. �y 0 w Ct O 51DE AS EACH SIDE AS U PROVIDE A MINIMUM 3" CONCRETE H U z COVER FOR ALL REINFORCING STEEL, ALL TRANSITION CAPS ARE CENTERED r4 cn OVER CORRESPONDING AUGER PILE. E. TRAN5ITION CAP DETAILS 18-022 REVIEWED FOR SHEET SCALE: NOT TO SCALE IANCE ST. LUCIE COUNTY S-3 CONSTRUCTION SET POU RED -I N-PLACE G" THICK (nominal) 3000p51 CONCRETE STRUCTURAL SLAB w/ #4'5 1.2" O.C. EW ELEVATION 5.5 refer to Section for beam details C-5 CTB-1 2x4 PRE ENGINEERED WOOD FLOOR TRUSSES @ 24" o.c. refer to shop drawings ! ELE TION +0' "F.F. I 1 I I : I ' 21 ?x I C I-, T. LEC' � CANTILEVER '�-5 li I v In 1 II I 1 2x10R.T. 5HEARWALL O N 1 5'-1 +0'-01, F.F. (T5C I; above) 38.3 kips LOAD BEAPUNO jOR :BE � U Oo - ------; -O N � m 7 LU LLJ ) Z_ O Z W y� LU L j MA50NR�SHEARWALL CTBPOURED-IN-PLACEG" THICK (nominal)3000F51CONCRETE_=--m____STRUCTURAL SLAB C('` Ibalcony) MA O RY - refer to details fa T i KY, PL! ;pen to beLTALT5 fe to sheet .: .....- .----- reinforcemen ,fpl" r 2 f.rr FRAMING Dr fr~r to [C,�—� ,. .�IIiTPCTUiUVL PkAN5 R DETAILS U s---- --r— -- i c _ .. - 5-. U YtLLKED IN=PL t - --- _ 3000psI CONCREiF efer to section — 5TRUCTURAL SLAB details Por reinforcement ELEVATION-1r.`rON�".r -a-5^ e.F.F. CTB—T 4 (,- --- 5 2 :_....._ __ ELEVATION L� 1 +0 '0" F F transition from m CT15-7 to CT5-8 I �> oN 4 M NRY EAR LL fig_ ) 2x 1 T. 1_ ELEVATOR 5 HAF7 WALLS SHALL BE CONSIDERED A COMPONENT OF THE ADJACENT MASONRY _ 5HEARWALL AND5HALL BE CONSTRUCTED IN A CON515TENT MANNER, A5 DEFINED 5ELOW. refer to section 1 for beam details 1. I F USH 77 I I I I ¢ I I , POURED -IN -PLACE G" THICK (nominal) (. 4 3000F51 CONCRETE --'— —�--- -- - - -- i STRUCTURAL SLAB w/ IFA #4'5 12" O.C. EW MASONRY 5HEARWALL OL ELEVATION 4_g +0'-0" F.F. CANTILEVER ALL MASONRY CONSTRUCTION ORIGINATING BELOW THE LOWEST ALLOWED HORIZONTAL SUPPORTING MEMBER @ I G.50' N.A.V.D. (FIRST FLOOR) SHALL BE FRANGIBLE CONSTRUCTION, UNLESS NOTED OTHERWISE. REFER TO SHEET 5-9 FOR FRANGIBLE WALL CONSTRUCTION DETAILS. >) 2x 10 T. LEDGER I FLOOR TgL15SE5 @ 2411 o.C. refer t shop drawings (2) 1 ALL WALLS DENOTED "MASONRY 5HEARWALL" (ILLUSTRATED AS ) ARE NOT FRANGIBLE AND SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE METHODS PRESCRIBED IN T E "TYPICAL WALL_ SECTION" ON THE DETAIL SHEET 5-9. 8" C.M.U. MASONRY SHORE -NORMAL 5HEARWALL w FILLED CELL COLUMNS @ 48" o.c. MAX. # I Gga, LADDER TYPE REINF. refer to TYPICAL WALL SECTION for details CTB-1 MASONRY 5HEARWALL all FM 8" C.M.U. MASONRY SHORE -NORMAL 5HEARWALL w FILLED CELL COLUMNS @ 48" o.c. MAX. t I Gga, LADDER TYPE REINF. refer to TYPICAL WALL SECTION for details (2) 2x 10 P.T. LEDGER w/ 8'x7" WEDGE ANCHOR G" FROM ENDS � @ 2411 O.C. typical for all wood floor truss bearing ledgers ALL ENCLOSED SPACES BELOW THE BASE FLOOD ELEVATION SHALL BE PROPERLY VENTED IN ACCORDANCE WITH FBC REGULATIONS - USE CAST-CRETE 8U8 PRECAST CONCRETE LINTELS (or equivalent) ABOVE ALL REQUIRED FLOOD VENTS IN MASONRY WALL APPLICATIONS - REFER TO ARCHITECTURAL DRAWINGS FOR VENT LOCATIONS 1 st FLOOK IF RAM I NG PLAN CONCKETE COLUMN LAYOUT SCALE: 1 /4" = I'-011 FIRST FLOOR CONCRETE TIE BEAM SCHEDULE MARK PLAN 51ZF REINFORCEMENT TOP of BEAM REMARKS D W TOP M. DOT. STIRRUPS CTB-1 24" 8" (2) #5 n/a (2) #5 #3 @ 1 2" O.C. +0'-O" TYPICAL 15t FLOOR BEAM exterior CT5-2 23" 1 2" (3) #5 n/a (3) #5 #3 @ 1 2" O.C. -0'-1 " 12" BEAM - FLOOR SUPPORTING CTB-3 24" 1 G" (3) #5 (3) #5 (3) #5 #3 @ 1 2" O.C. +0'-0'' INTERIOR I G" BEAM @ GARAGE CT15-4 varies 1 2" (3) #5 n/a (3) #5 #3 @ 1 2" O.G. sloped BOTTOM @ -2'-0" B.F.F. CTB-5 1 24" 1 2" (2) #5 (2) #5 (2) #5 #3 @ 1211 O.C. +0'-0" 1 2" BEAM - EXTERIOR WALL BEARING CTB-5a varies 1 2" (2) #5 n/a (2) #5 #3 @ 1 2" O.C. sloped BOTTOM @ -2'-0" B.F.F. CTB-G vanes 8" (2) #5 n/a (2) #5 #3 @ 1 2" O.G. sloped BOTTOM @ -2'-0" B.F.f. CTB-7 20" 8" (2) #5 n/a (2) #5 #3 @ 1 2" O.C. vanes TYPICAL PATIO SLAB BEAM CT13-7a 1 7" 8" (2) #5 n/a (2) #5 #3 @ 1 2" O.G. Vanes BOTTOM @ -2'-0" B.F.F. CTB-8 23" 8" (2) #5 n/a (2) #5 #3 @ 1 2" O.C. O'- TYPICAL 15t FLOOR BEAM Interior -�—W CTB-I • • G" PATIO SLAB 0 REINFORCEMENT t DIMENSIONS •. ! ARE IDENTICAL TO CTB- 1 CTB- I a CTB-4 SPECIALLY LOADED BEAM (3) #515 cont. TOP STEEL • 0 (3) #5x72" left side TOP STEEL (4) #3 STIRRUPS @ G" O.C. 0 0 (typical at beam ends) #3'5 @ 1 2" O.C. elsewhere -••' • • •- (3) #5'5 cont. BOTTOM STEEL CTB-7a CT13-2a CTB-7b SIMILAR w/ I G11 DEPTH CONCRETE COLUMN SCHEDULE MARK PLAN SIZE REINFORCEMENT REMARKS B H VERTICAL TIES C 8" 1 G" (4) #5 #3 @ 1 2" O.C. TYPICAL FORM -POURED COLUMN C2 8" 1 G" (G) #5 #3 @ 1 2" O.C. TYPICAL CORNER FORM -POURED COLUMN C3 1 2" 1 G" (G) #5 #3 @ 1 2" O.C. TYPICAL FORM -POURED COLUMN - ELONGATED C4 1 1 2" 1 2" (4) #5 N/A 1 2" say. PILASTER BLOCK COLUMN - see note below C5 18" 1 24" (8) #5 #3 @ 1 2" O.C. GARAGE DOOR COLUMN CG 1 2" 1 2" (G) #5 #3 @ 1 2" O.C. OPTIONAL 12"x 1 2" COLUMN C7 I G" I G" Q #5 N/A I G" sq. PILASTER BLOCK COLUMN - see note below —B-7� Lt-71 CID C-I C-2 C-3 SEE PLAN FOR ORIENTATION �fI 'k— . • • C-6 C_7 40 W o C— 5 C-G MAY BE USED IN PLACE OF C-4 C-G MAY BE USED IN PLACE OF C-5 i REVIEWED FOR O � CODE COMPLIANCE ,�, . Con ST. LUCIE COUNTY CONTRACTOR SHALL COORDINATE ALL D�?FS AND Z ELEVATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION. THESE PLANS ARE NOT FOR CONSTRUCTION UNLESS STAMPED "Construction Set", DATED, SIGNED AND SEALED BY THE ENGINEER. PR18 022 ALL CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL SHEET JURISDICTIONAL PERMITS, CONDITIONS AND CONTRACT DOCUMENTS. S-4