Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutROOF TRUSSESA Do not stand on trusses until they are braced per BCSI & properly nailed to straps and hangers !!
HIP CARRIER LOCATED AS DIMENSIONED ON LAVotrr I/ .
FABRICATION AGREEMENT
TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED
JI\ =LIFE SAFETY WARNING
This symbol identifies Life Safety Warnings that
should be read and given special attention to all
persons installing trusses.
SPACING NOTE
All trusses are to be set 2'-0" on
center except as noted.'
MULTIPLE PLY TRUSSES MUST BE FASTENED
TOGETHER PER ENGINEERING BEFORE
SETTING. REFER TO ENGINEERING DRAWING
A TO DETERMINE IF MULTIPLE PLY. f
DON'T LIFT TRUSSES
'H SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
30' Sp nor less /� sup to ue span A
/U, ` Spreeder Bar
\60 degrees
or less I
Tap Ilna �— V2 span — Tag fine .g-ApProx 2/51"
aPProx. 1/2 of Span.
REFER TO BCSI REFER TO SCSI
Truss must be set this way if crane is used., Truss must be set this way if crane is used.
Truss Is an example, your truss may not match. Truss is an example, your truss may not match.
Insist crane operator sets truss this way. IInsist crane operator sets truss this way.
All load bearing walls, headers,
beams, & lintels must be in place
at indicated height before trusses
are Installed. el I
AIR HANDLER NOTE
Unless noted elsewhere on this layout, these trusses are not
designed for air handlers in the roof or for any other A/C
requirements. This may be in conflict with building code and A/C
Design requirements. Consult with Building Department and A/C
Contractor.
ARN/NG /!
The size of these trusses makes it necessary that they a set by a profeesional builder
familiar with and experienced in the problems and dangers of setting large span trusses.
The builder and erector should consult with an engineer licensed in Florida specializing
in wood roof trusses about the safe erection of these trusses. The engineer should be at
the job site when trusses*e erected to provide supervision and advice.
SEAT PLATES BY CHAMBERS TRUSS
Hatch
4 IBRG WALL @ 34'
�BRG WALL @ 221- 4"
nCI EILING @ 22'- "
sep REPRESENTS A HANGER
HANGER SCHEDULE
USE HUS26 FOR 2X4, SUH46 FOR 4X2 EXCEPT AS SHOWN
CARRIED
TRUSS
CARRYING
TRUSS
I NGER ID
FASTENER FOR
CARRIED TRUSS
FASTENER FOR
CARRYING TRUSS
G R E
G RJ
H U S28
(8) 16d nails
(22) 16d nails
G
RJ
G
R B
I HD26-2
(12) 10d nails
(18) 16d nails
'Please refer to Standard Engine,
10d=0.148" x 3"
NOTES:
*ALL BEAMS B)
*CEILINGS ARE
package for general instuction on installing hangers
16d=0.162" x 3 1/2"
OTHERS.
FLAT THIS
LEVEL.
i
METAL ROOFS SHOW IMPERFECTIONS. SPECIAL INSTALLATION CARE MUST BE TAKEN.
Y
CORNDER JACKS
ARE NOT BEVELED.
O
SEE STANDARD
ENGINEERING.
O t
ie
o06
n
24" O.C. THRU
CORNER JACKS
ONLY 24.
CORNER DETAIL
OVERHANGS NOT SHOWN FOR CLARITY
F4.5 r
PLUMB CUT END
2X4 TOP CHORD
WALL HEIGHT VARIES
END DETAIL: TYPICAL
'he undersigned acknowledges and agrees:
1. Trusses will be made in strict accordance with this truss placement diagram layout, which is the sole authority for
etermining successful fabrication of the trusses.
2. All dimensions in this layout have been verified by the undersigned.
3. Unless will notice is provided by certified mail to Chambers Truss within ten (10) days of delivery the
ndersigned agrees that no backcharges will be allowed. In the event such written notice is furnished Chambers Truss
hall have three (3) business days in which to begin repairs required, or to substitute other trusses, at Chambers option.
after 10 days of delivery remedy will be according to Florida statute 558.
4. The unders fined acknowledges receipt of 'BCSI' summary sheet by TPI & WTCA.
5. Delivery is to job site. It is the buyefs responsibility to make the job site suitable for delivery. Chambers Truss has
IS sole authority to determine the suitability of the job site or a portion of the job site for delivery. Chambers Truss will
e responsible for dump delivery only. The buyer is responsible for additional delivery expenses 9 Chambers Truss has
I redeliver because job site is not prepared for delivery or buyer is not prepared for delivery of trusses. Buyer is
sponsible to Chambers Truss for towing costs due to site conditions.
6. Price as shown in paragraph 7 below is subject to change if any changes are made in this layout A $50 per hour
.e for revisions may be charged by Chambers Truss.
7. This is a PURCHASE ORDER to Chambers Truss of the sum agreed to, or if no agreement a reasonable price.
voice will be made on delivery and paid within terms of net on delivery. Invoice may be made at scheduled date of
:livery if buyer cannot accept delivery of fabricated trusses. The undersigned agrees to pay Chambers Truss
lasonable attomeYs fee for collections in event of payment not timely made. 1-1/2 % per month service charge will be
tded for all sums not paid within terms.
8. Signature or initials anywhere on this sheet constitutes agreement to all terms herein.
9. In consideration of Chambers Truss extending credit for this material the undersigned unconditionally guarantees
ayment when due of any and all indebtedness owed to Chambers Truss by any entity receiving material and the
adersigned agrees to pay such indebtedness including attorneys fees, if default in payment for material be made by the
cipient.
10. In the event of any litigation concerning this agreement; the items furnished hereunder or payments referred to
.vein, the parties agree that the sole venue for any such action will be Saint Lucie County, Florida.
11. Design responsibilities are per ""National Standard And Recommended Guidelines On Responsibilities For
mstmction Using Metal Plate Connected Wood Trusses ANSI/rPI1WTCA 4 - 2002'"'
12. Warranty is per Chambers Truss Warranty attached.
A spreader bar may be required per "BCSI" to prevent injury & damage.
Multiple ply trusses must be fastened together per engineering before they are
set, failure to do so can result in roof collapse.
Temporary and p ry permanent bracing are required and can save life and property
and is the responsibility of the truss erector.
Study the contents of the information packet included on delivery before
setting trusses.
-991111111.
Trusses must be set and braced per design to prevent injury & damage.
Trusses must be set plumb and square
Do not set bunks or stack of plywood, roofing material or any other
concentrated loads on trusses, this can cause collapse.
DO NOT INSTALL TRUSSES USING THIS
USE PLAN DELIVERED WITH TRUSSES TO SET TRUSSES
CHAMBERS TRUSS INC
can er venue
Fort Pierce, Florida 34982-6423
800.551.5932
Fort Pierce 772-465-2012 Fax 772-465-8711
Vero Beach 772-569-2012 Stuart 772-286-3302
Web Site: CHAMBERSTRUSS.COM
Email: MAIL@CHAMBERSTRUSS.COM
SCANNi'
BY
Lucie County
DESIGN CRITERIA
LOADING/DESIGN CRITERIA REDUCIBLE
PER CODE SUCH AS SBC 1604.6.1
County
Saint Lucie County
Building Department
Saint Lucie County
Wind Design Criteria
ASCE 2010
Wind Design Method
MWFRS(Directional)/C-C hybrid Wind ASCE 7-10
Roofing Material
Metal
Loading in PSF
Roof R.D.L. Floor
Top Chord Live
20 40
Top Chord Dead
15 4.2 20
Bottom Chord Live
*10-Non Conccurent *10-Non
Conccurent
Bottom Chord Dead
10 3 - 10
Total Load
55 7.2 80
Duration Factor
1.25 0
Wind Speed
170mph
Top Chord C.B.
Sheathing by builder
Bottom Chord C.B.
Sheathing by builder
Highest Mean Height
15'
Building Type
Enclosed
Building Category
II: Non Restrictive
Exposure Category
Miles from Ocean
D> Flat/ unobstructed/ exposed to wind over water...
0
Conforms to Florida Building Code 2017
Verify DESIGN CRITERIA shown above with the
building department and your engineer.
Design Criteria is the responsibility of the
Building Designer and/or Engineer of Record
Chambers Truss Inc. Drawing Name: 75571
SCALE: 1/4" = 1'-0"
299 total trusses, 78 unique designs
Designer: BLW Reviewed by:
Date: 10/15/18 Revised 11/12/18
FOR
Sion Homes
DESCRIPTION:
ACQUAVISTA / LOT 1
Page 3 of 3 CUSTOMER INITIALS EACH PAGE
75571 ilillilIlilto m _
Q =LIFE SAFETY WARNING
This symbol identifies Life Safety Warnings that
should be read and given special attention to all
persons installing trusses.
I SPACING NOTE
All trusses are to be set 2'-0" on
center except as noted.
MULTIPLE PLY TRUSSES MUST BE FASTENED
TOGETHER PER ENGINEERING BEFORE
SETTING. REFER TO ENGINEERING DRAWING
TO DETERMINE IF MULTIPLE PLY. ..
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
30' Span or less '
60 degrees
or less
Teg line � 112 span >
approx.
REFER TO BCSI
Truss must be set this way if crane is used.
Truss is an example, your truss may not match.
Insist crane operator sets truss this way.
Tag line �Approx 2/3 to
12 of Span.
REFER TO BCSI
Truss must be set this way if crane is used.
Truss is an example, your truss may not match.
Insist crane operator sets truss this way.
All load bearing walls, headers,
beams, & lintels must be in place
at indicated height before trusses
A are installed. �i
AIR HANDLER NOTE
Unless noted elsewhere on'this layout, these trusses are not
designed for air handlers in the roof or for any other A/C
requirements. This may be inl,conflict with building code and A/C
Design requirements. Consult with Building Department and A/C
Contractor.
WARNING
The size of these trusses makes it necessary that they a set by a profeesional builder
familiar with and experienced in the problems and dangers of setting large span trusses.
The builder and erector should consult with an engineer licensed in Florida specializing
in wood roof trusses about the safe erection of these trusses. The engineer should be at
the job site when trusses are erected to provide supervision and advice.
Recommended STRONGBACK for Floor Trusses
Refer to information on truss engineering drawings.
(2) led nails Q top & bottom of 2x4 vertical block.
2x6 (MIN) STRONGBACK restrained at each end. Secure w/(3)16d nails @ each vertical. Locate STRONGBACK as clo}e to bottom cord as possible.
TRONGBACKS are recommended to MINIMIZE VIBRATION I
0 CONNECTIONS DESIGNED
AND SUPPLIED BY OTHERS
o
O
0
0
N
SQUARE CUT END
4X2 TOP CHORD
LEDGER HEIGHT 10'- 9"
END DETAIL: TYPICAL F
1ST LEVEL
NOTES:
*ALL BEAMS BY OTHERS.
*ALL TRUSS TO LEDGER CONNECTIONS
*CEILINGS ARE FLAT THIS LEVEL.
DESIGNED & SUPPLIED BY OTHERS.
A Do not stand on trusses until they are braced per BCSI & properly nailed to straps and hangers !I
HLL rLUUK LLUULK I UFJ6 (a) 10` J" THIS► LEVEL
FABRICATION AGREEMENT
TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED
he undersigned acknowledges and agrees:
1. Trusses will be made in strict accordance with this truss placement diagram layout which is the sole authority fa
etermining successful fabrication of the trusses.
2. All dimensions in this layout have been verified by the undersigned.
3. Unless written notice is provided by certKW mail to Chambers Truss within ten (10) days of delivery the
ndersgned agrees that no backcharges will be allowed. In the event such written notice is furnished Chambers Truss
hall have three (3) business days in which to begin repairs required, or to substitute other trusses, at Chambers option.
fter 10 days of delivery remedy will be according to Florida stahite 558.
4. The undersigned acknowledges receipt of 'BCSI' summary sheet by TPI & WTCA
5. Delivery is to job site. It is the buyers responsibility to make the job site suitable for delivery. Chambers Truss has
Is sole authority to determine the suitability of the job site or a portion of the job site for delivery. Chambers Truss will
a responsible for dump delivery only. The buyer is responsible for additional delivery expenses B Chambers Truss has
I redeliver because job site is not prepared for delivery or buyer is not prepared for delivery of trusses. Buyer is
sponsible to Chambers Truss for towing costs due to site conditions.
6. Price as shown in paragraph 7 below is subject to change 'd any changes are made in this layout A $50 per hour
e for revisions may be charged by Chambers Truss.
7. This is a PURCHASE ORDER to Chambers Truss of the sum agreed to, or B no agreement a reasonable price.
ivoice will be made on delivery and paid within terms of net on delivery. Invoice may be made at scheduled date of
-livery it buyer cannot accept delivery of fabricated trusses. The undersigned agrees to pay Chambers Truss
iasonable attorneys fee for collections in event of payment not timely made. 1-112 % per month service charge will be
ided for all sums not paid within terms.
8. Signature or initials anywhere on this sheet constitutes agreement to all terms herein.
9. In consideration of Chambers Truss extending credit for this material the undersigned unconditionally guarantees
3yment when due of any and all indebtedness owed to Chambers Truss by any entity receiving material and the
ldersigned agrees to pay such indebtedness including attorneys fees, if default in payment for material be made by the
10. In the event of any litigation concerning this agreement, the items furnished hereunder or payments referred to
:rein, the parties agree that the sole venue for any such action will be Saint Lurie County, Florida.
11. Design responsibilities are per ""National Standard And Recommended Guidelines On Responsibilities For
instruction Using Metal Plate Connected Wood Trusses ANSI/TPI/WTCA 4 - 2002'"'
12. Warranty is per Chambers Truss Warranty attached.
A spreader bar may be required per "BCSI" to prevent injury & damage.
Multiple ply trusses must be fastened together per engineering before they are
set, failure to do so can result in roof collapse.
Temporary and permanent bracing are required and can save life and property
and is the responsibility of the truss erector.
Study the contents of the information packet included on delivery before
setting trusses.
Trusses must be set and braced per design to prevent injury & damage.
Trusses must be set plumb and square
Do not set bunks or stack of plywood roofing material or any other
concentrated loads on trusses, this can cause collapse.
DO NOT INSTALL TRUSSES USING THIS
USE PLAN DELIVERED WITH TRUSSES TO SET TRUSSES
CHAMBERS TRUSS INC
3105 Oleander Avenue
Fort Pierce, Florida 34982-6423
800-551-5932
Fort Pierce 772-465-2012 Fax 772-465-8711
Vero Beach 772-569-2012 Stuart 772-286-3302
Web Site: CHAMBERSTRUSS.COM
Email: MAIL@CHAMBERSTRUSS.COM
DESIGN CRITERIA
LOADINGIDESIGN CRRERIA REDUCIBLE
PER CODE SUCH AS SBC 160s.6.1
County
Saint Lucie County
Building Department
Saint Lucie County
Wind Design Criteria
ASCE 2010
Wind Design Method
MWFRS(Directional)/C-C hybrid Wind ASCE 7-10
Roofing Material
Metal
Loading in PSF
Roof R.D.L. Floor
Top Chord Live
20 40
Top Chord Dead
15 4.2 20
Bottom Chord Live
*10-Non Conccurent '10-Non
Conccurent
Bottom Chord Dead
10 3 10
Total Load
55 7.2 80
Duration Factor
1.25 0
Wind Speed
170mph
Top Chord C.B.
Sheathing by builder
Bottom Chord C.B.
Sheathing by builder
Highest Mean Height
15,
Building Type
Enclosed
Building Category
It: Non Restrictive
Exposure Category
D> Flat/ unobstructed/ exposed to wind over water...
Miles from Ocean
0
Conforms to Florida Building Code 2017
Verify DESIGN CRITERIA shown above with the
building department and your engineer.
Design Criteria is the responsibility of the
Building Designer and/or Engineer of Record
Chambers Truss Inc. Drawing Name: 75571
SCALE: 1/4" = V-0"
299 total trusses, 78 unique designs
Designer: BLW Reviewed by: -
Date: 10/15/18 Revised 11/12/18
FOR
Sion Homes
DESCRIPTION:
ACQUAVISTA / LOT 1
Page 1 of 3 CUSTOMER INITIALS EACH PAGE
75571
=LIFE SAFETY WARNING
This symbol identifies Life Safety Warnings that
should be read Od given special attention to all
persons installing trusses.
SPACING NOTE
All trusses are to be set 2'-01, on
center except as noted.
MULTIPLE PLY TRUSSES MUST BE FASTENED
TOGETHER PER ENGINEERING BEFORE
SETTING. REFER TO ENGINEERING DRAWING
,. TO DETERMINE IF MULTIPLE PLY. A
WITH SPANS LONGER THAN
30' BY THE PEAK.
I CONSULT BCSI
30' Soein or less
60 degrees
or less
�- Tag line 112 spanapprox.
REFER TO BCSI
Truss must be set this way if crane is used.
Truss is an example, your truss may not matt
Insist crane operator sets truss this way.
All load bee
beams, & lin
at indicated
ff
•
Tag line <--Appmx 213 to
IY2 of Span.
REFER TO BCSI
Truss must be set this way if crane is used.
Truss is an example, your truss may not match.
Insist crane operator sets truss this way.
ling walls, headers,
.Is must be in place
height before trusses
installed.
AIR HANDLER NOTE
Unless noted elsewhere on this layout, these trusses are not .
designed for air handlers in the roof or for any other A/C
requirements. This may be in conflict with building code and A/C
Design requirements. Consult with Building Department and A/C
Contractor.
e
RN/NG
e
The size of these trusses makes it necessary that they a set by a profeesional builder
familiar with and experienced in the problems and dangers of setting large span trusses.
The builder and erector should consult with an engineer licensed in Florida specializing
in wood roof trusses about the safe erection of these trusses. The engineer should be at
the job site when trusses are erected to provide supervision and advice.
Recommended STRONGBACK for Floor Trusses
Refer to information on, truss engineering drawings.
(2) led nails @ top & bottom of 2x4 vertical
2x6 (MIN) STRONGBACK restrained at each end.
are recommended to
w/(3)16d nails C each vertical. Locate STRONGSACK as
VIBRATION
to bottom cord as possible.
SEAT PLATES BY CHAMBERS TRUSS
Hatch Legend
41BRG WALL @ 34'
�BRIG WALL @ 221- 4"
CEILING @ 22'- 4"
REPRESENTS A HANGER
HANGER SCHEDULE
I ISF HLIS26 FOR 2X4. SU I46 FOR 4X2 EXCEPT AS SHOWN
CARRIED
TRUSS.
CARRYING
TRUSS
HANGER ID
FASTENER FOR
CARRIED TRUSS
FASTENER FOR
CARRYING TRUSS
FLM
GFZ
THD46
(12) 10d nails
(18) 16d nails
FLL
GFZ
THD46
(12) 10d nails
(18) 16d nails
FLK
GFZ
THD46
(12) 10d nails
(18) 16d nails
'Please refer to Standard Engineering package for general instuction on installing hangers
10d=0.148" x 3" 16d=0.162" x 3 1/2"
0 CONNECTIONS DESIGNED
AND SUPPLIED BY OTHERS
NOTES:
*ALL BEAMS BY OTHERS.
*ALL TRUSS TO LEDGER CONNECTIONS DESIGNED & SUPPLIED BY OTHERS.
*CEILINGS ARE TO BE BALANCE FRAME BY BUILDER AS NEEDED.
i
ADO not stand on trusses until they are braced per BCSI & properly nailed to straps and
METAL ROOFS SHOW IMPERFECTIONS. SPECIAL INSTALLATION CARE MUST BE TAKEN.
Do not set floor trusses upside down! Refer to engineering drawings.
hangers !!
0
0
0
0
CV
HIP CARRIER
LOCATED AS DIMENSIONED ON LAYOUT
CORNDER JACKS
ARE NOT BEVELED.
Y
q
r
SEE STANDARD
ENGINEERING.
d w
p
NUO
N
2C O.C. THRU
CORNER JACKS
ONLY 24' ' 1-1/1
CORNER DETAIL
OVERHANGS NOT SHOWN FOR CLARITY
SQUARE CUT END
4X2 TOP CHORD
LEDGER HEIGHT 23'- 9"
END DETAIL: TYPICAL FLOOR 2ND LEVEL
SQUARE CUT END
4X2 TOP CHORD
LEDGER HEIGHT 23'- 9"
END DETAIL: RAISED CEILING 2ND
FABRICATION AGREEMENT
TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED
e undersigned acknowledges and agrees:
1. Trusses will be made in strict accordance with this truss placement diagram layout, which is the sole authority for
termining successful fabrication of the trusses.
2. All dimensions in this layout have been verified by the undersigned.
3. Unless written notice is provided by certified mail to Chambers Truss within ten (10) days of delivery the
dersigned agrees that no badkcharges will be allowed. In the event such written notice is furnished Chambers Truss
all have three (3) business days in which to begin repairs required, or to substitute other trusses, at Chambers option.
er 10 days of delivery remedy will be according to Florida statute 558.
4. The undersigned acknowledges receipt of 'BCSI' summary sheet by TPI & WTCA
5. Delivery is to job site. It is the buyer's responsibility to make the job site suitable for delivery. Chambers Truss has
sole authority to determine the suitability of the job site or a portion of the job site for delivery. Chambers Truss will
responsible for dump delivery only. The buyer is responsible for additional delivery expenses S Chambers Truss has
redeliver because job site is not prepared for delivery or buyer is not prepared for delivery of trusses. Buyer is
3ponsible to Chambers Truss for towing costs due to site conditions.
6. Price as shown in paragraph 7 below is subject to change if any changes are made in this layout A $50 per hour
3 for revisions may be charged by Chambers Truss.
7. This is a PURCHASE ORDER to Chambers Truss of the sum agreed to, or if no agreement a reasonable price.
iori a will be made on delivery and paid within terms of net on delivery. Invoice may be made at scheduled date of
livery if buyer cannot accept delivery of fabricated trusses. The undersigned agrees to pay Chambers Truss
3sonable attorneys fee for collections in event of payment not timely made. 1-1/2 % per month service change will be
ded for all sums not paid within terms.
8. Signature or initials anywhere on this sheet constitutes agreement to all terns herein.
9. In consideration of Chambers Truss extending credit for this material the undersigned unconditionally guarantees
ymenl when due of any and all indebtedness owed to Chambers Truss by any entity receiving material and the
dersigned agrees to pay such indebtedness including attorneys fees, if default in payment for material be made by the
10. In the event of any litigation concerning this agreement, the hems furnished hereunder or payments referred
:rein, the parties agree that the sole venue for any such action will be Saint Lucie County, Florida.
11. Design responsibilities are per ""National Standard And Recommended Guidelines On Responsibilities I
mstmction Using Metal Plate Connected Wood Trusses ANSI/rPIAWTCA 4 - 2002""
12. Warranty is per Chambers Truss Warranty attached.
TITLE
A spreader bar may be required per "BCSI" to prevent injury & damage.
Multiple ply trusses must be fastened together per engineering before they are
set, failure to do so can result in roof collapse.
Temporary and permanent bracing are® fired and can save life and property
and is the responsibility of the truss erector.
Study the contents of the information packet included on delivery before
setting trusses.
Trusses must be set and braced per design to prevent injury & damage.
Trusses must be set plumb and square
Do not set bunks or stack of plywood, roofing material or any other
concentrated loads on trusses, this can cause collapse.
DO NOT INSTALL TRUSSES USING THIS
USE PLAN DELIVERED WITH TRUSSES TO SET TRUSSES
CHAMBERS TRUSS INC
3105 Oleander Avenue
Fort Pierce, Florida 34982-6423
800-551-5932
Fort Pierce 772-465.2012 Fax 772-465-8711
Vero Beach 772-569-2012 Stuart 772-286-3302
Web Site: CHAMBERSTRUSS.COM
Email: MAIL@CHAMBERSTRUSS.COM
LOADINGIDESIGN CRRERIA REDUCIBLE
PER CODE SUCH AS SBC 1604A.1
DESIGN CRITERIA
County
Saint Lucie County
Building Department
Saint Lucie County
Wind Design Criteria
ASCE 2010
Wind Design Method
MWFRS(Directional)/C-C hybrid Wind ASCE 7-10
Roofing Material
Metal
Loading in PSF
Roof R.D.L. Floor
Top Chord Live
20 40
Top Chord Dead
15 4.2 20
Bottom Chord Live
*10-Non Conccurent *10-Non
Conccurent
Bottom Chord Dead
10 3 10
Total Load
55 7.2 80
Duration Factor
1.25 0
Wind Speed
170mph
Top Chord C.B.
Sheathing by builder
Bottom Chord C.B.
Sheathing by builder
Highest Mean Height
15,
Building Type
Enclosed
Building Category
If: Non Restrictive
Exposure Category
D> FlaV unobstructed/ exposed to wind over water...
Miles from Ocean
0
Conforms to Florida Building Code 2017
Verify DESIGN CRITERIA shown above with the
building department and your engineer.
Design Criteria is the responsibility of the
Building Designer and/or Engineer of Record
Chambers Truss Inc. Drawing Name: 75571
SCALE: 1/4" = 1'-0"
299 total trusses, 78 unique designs
Designer: BLW Reviewed by:
Date: 10/15/18 Revised 11/12/18
FOR
Sion Homes
DESCRIPTION:
ACQUAVISTA / LOT 1
Page 2 of 3 CUSTOMER INITIALS EACH PAGE