Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BUILDING PLAN PAGE 1-10
PROTECT SYRUP LINES FROM TRUSS ANGLE BUNDLED SYRUP LINES & FILTERED WATER LINE BOTTOM CHORD OF— ROOFTRUSS I NOTE: SYRUP LINE BUNDLE (OWNER FURNISHED, AND INSTALLED) 1 SYRUP LINES IN ATTIC SPACE Scale: 3/4" = V-0" K7Si711 MOP SINK j FAUCET, SEE PLUMBING i DRAWINGS. -/ FRP OVER 1/2" CDX PLYWOOD 18 GA. S.S. BACK WALL PANELS TO 6-0" A.F.F. v � P % NOTE: MOP SINK SIZED PER PLUMBING FIXTURE SCHEDULE (SHEET P1) - 2x8 STUD WALL SLOPE �j 5'-0" HIGH 18 GA. S/S PANEL (213 FINISH) @ ALL CAN WASH WALLS OVER 5/8" EXT. GRADE (MARINE) PLYWOOD. PROVIDE FULL HEIGHT FRP ABOVE 5-0". S/S PANELS TO BE ONE PIECE BENT @ CORNERS W/ DRILLED HOLES FOR FAUCET & VALVES PRIOR TO INSTALLATION. NO SEAMS ARE ACCEPTABLE. SILICONE CAULK @ EDGES FOR WATER TIGHT SEAL. DRAINPIPE, REFER TO PLUMBING SHEETS 6 ELEVATION AT MOP SINK Scale: 3/4' = V-0" 2 NOT USED 2'-0" I 7 ELEVATION AT MOP SINK Scale: 3/4" = V-0" BEND S.S. OVER BASE TILE 1/4" MIN. TYP. CAULKING 2'-10" A.F.F. TOP OF TRIM 1x4 MAPLE RAIL STAIN MARLITE WS-1 3 SECTION DETAIL - CHAIR RAIL Scale: 6" = V-0" NUTONE MODEL# 672R EXHAUST FAN 4" PVC CONDUIT THRU SIDEWALL TO POS TERMINAL BOX (CHORD. LOCATION OF CONDUIT IN FIELD) LAMINATED SHELVES BY NEVAMAR COLOR: STUDIO WHITE MATRIX (MR-7-1T TEXTURED) K&V #87 AND STANDARDS (42") W/ #187LL ANO BRACKETS (18") THERMOSTATS (3) LIGHT SWITCHES BANKS M-11 S/S TABLE WITH - REINFORCED TOP HOLD-UP BUTTON 4 NOT USED 5 NOT USED 4'-0" Z-O" EQ. EQ. CABINET DOOR CABINET DOOR / o PROVIDE WOOD v cwi BLOCKING FOR WALL Cl�" TAPE/STEREO CABINET, TYP. MOD M 1" CLEAR SPACE o SECURITY' Back- PS ° BETWEEN BACK OF MONITOR SHELF AND CABINET WALL C.. 1, S' Q MANUALS \ — Digital M/B Digital M/B Back -UPS Controllers Digital M/B ��- 1-1 Ell Ethernet Switch mTIME CLOCK PRINTER En -_. KEYBOARD CALL. C? O No HOLD-UP--- BUTTON FILE CABINETS BY OWNER 2 6 \FILE CABINETS ON WHEELED PLATFORM OR CASTERS 8 MILLWORK SECTION AT OFFICE Scale: 3/4" = l'-0" 9 MILLWORK ELEVATION AT OFFICE Scale: 3/4" = V-0" 0 N N O a -oovm m 6Ni N W � J QMj pmj LL W O V u ClN L ,., E > m m ZD (,I Z o c d U 0� N W W I-- W =Z U 0 � Z Q W U r_ o J p] rn J U � � L W T V Z UN O Z p J N LL Hz U o v N L m n W O N " M- Z O a N N N Y Z N N N C'y O U J Q N N LL LL 6 w U 0 O a w Of W m O F- O Z W tY Q w _ LL U Z W 2 Z U) W 0 W 2 7 0 z Z Q z z w U O 0 w U) W O F- 0 Lu w 0- 0 D_ Lu w 2 F- O J J Q Z Q F- } a O U U I_ U) W LU w co J U) LU W d X w U) O Q W _I W Y Z_ W n O z Q Lu LLI U t LL F- w LL w O x v7 RELEASE DATE COMMENT RESPONSE 03/28/19 z KITCHEN REVISION 06/26/19 3 OWNER REVISION 01/02/20 a s 6 PROJECT NO. 2018-002 ISSUE DATE 12/21/18 DRAWN CHECKED GM - HDH SHEET NO: Alb TEMPERED GLASS w Q w U N 0 SCHEDUL NARROW FRAME TYPE A STOREFRONT DOOR TYPES W W W W w am w O X C?N Nz: N u I SCHEDULE SCHEDULE T SCH L SCHEDULE METAL DOOR SOLID CORE SOLID CORE FLUSH PAIR TYPE B TYPE C TYPE D TYPE E 1-3/4" FLUSH DOOR 1-3/4" WOOD DOOR, 1-3/4" WOOD DOOR, 1-3/4" WOOD DOOR, BIRCH BIRCH BIRCH IV INDICATES OPERATIONAL DOOR) FRAME TYPES 2 SCHEDULE CV 2' ,SCHEDULE ' (V (V W LU J J 0 0 Q 2 = TYPE SF-1 TYPE HM-1 DOOR SCHEDULE QUANTITY 0 w 2 cq T FRAME DETAIL Y Q W X oD 0 O V) _ W = F- (W O U w Y O w w z F=- a W� U) O w U ZQ D w g 0 C) Y X UJ w > ? a = 4 0 LU 2 Co Q -� = W 2 (n H MARK SIZE DOOR FRAME T-O" X T-0" (PAIR) TYPE A SF-1 3 PR 1 1 1 1 1- - - - - 2 16 2B1,2 3C AA �2 T-0"X6-8" TYPE C HM-I 1.5PR - - _ _ _ _ _ _ _ _ 4 1D 2D �3 3'4" X T-0" TYPE A SF-1 1.5 PR 1 1 1 - - - - - 2 1 B 261,2 3C AA ® T-6"XT-0" TYPE B HM-1 1.5PR 1 1 1 - 1 2 1 - 1 1C 2C 3C BB �5 T-0"x6'-8" TYPE D HM-'1 1.5PR 1 - - - - 2 - 1 EA. 3 1D 2D �6 3'-0"X6-8" TYPE D HM-1 1.5FIR 1 — 1 1 - - - 2 - 1EA. 3 1D 2D - (7) V-6"X6-8"(PAIR) TYPE E HM-I 1.5PR 1 1 5 CC ® 3'-0"X6'-8" DOORS BY COOLER MANUFACTURER - SEE SHEET A-13 T-0"X6-8" DOORS BY COOLER MANUFACTURER — SEE SHEET A-13 AA:^TO BE USED WHEN HURRICANE RATING IS REQUIRED: YKKAP - FRAME: YES 45F-S FL12926.R2 / DOOR: 201D FL5851.135 \J BB: TO BE USED WHEN HURRICANE RATING IS REQUIRED: CECO - FRAME: ZHDL.R27576 / DOOR ZHCW.R27575, FL 4553.R10 ; 3 CC: ASA ASTRIGAL ID RIGHT DOOR; PASSAGE HANDLESET ON LEFT -FLUSH BOLT ON INACTIVE LEAF ) HARDWARE SET NO.. 1: (LOCKNET SERIES DOOR PACKAGE) SPECIFICATIONS: DOORFRAME&HARDWARE INCLUDING VISION PANELW/FLAP,CONTIN000S HIN/V GE��\\ DIVISION 8: DOORS, WINDOWS AND GLASS HEAVY DUTY CLOSER AND PANIC HARDWARE. ORDERED THROUGH LOCKNET (800) J11(J �887-4307. COORDINATE WITH SECURITY VENDOR. SECTION 8B: INTERIOR WOOD CORE DOORS AND FRAMES 1 EA. T-6" X 7'-0" X 1.75" X 16 GA. X G60 GALVANIZED LOCKNET SECURITY DOOR �-'`� GENERAL PROVISIONS 1 EA. T-6" X T-0" X (5-7/8" OR 6-3/4") JAMB DEPTH X 14 GA. X G60 GALVANIZED X WELDED IN PLACE EOA X 1/4" X 2-1/2" HR PLATE SPREADER BAR X 4-SIDED 1. SCOPE: FURNISH AND INSTALL ALL INTERIOR WOOD CORE WELDED DOOR FRAME X FACTORY FINISH PAINTED 8 EA. 3/4"0 COVER PLUGS (BLACK) DOORS AND RELATED ALUMINUM FRAMES. REFER TO 1 EA. AIR LOUVER VLF-IG-PVC-1/2" LEXAN - 9" X 9" GALVANIZED SECURITY VISION NATIONAL ACCOUNT DIRECTORY. 1 EA. PEMKO CDHFM82SLF-HD FULL MORTISE CONT. GEARED ALUM, HINGE X 628 1 EA. SECURITY LATCH GUARD X FULL LENGTH X TORX SD/ST SMS X FACTORY FINISH MATERIALS 1 EA. ARROW 1250S X EO X AL EXIT DEVICE 1 EA. DORMA 8616 X DS X FCOV S SN1 X AL CLOSER 1. DOORS ARE WOOD CORE SOLID DOORS. SEE DOOR SCHEDULE 1 EA. ROCKWOOD 24" X 40" X .050 X US32D X SECURITY TORX SD/ST SMS FOR SIZE, MATERIAL, HARDWARE, AND FINISH.FRAMES SHALL ARMOR PLATE ON PUSH SIDE BE HOLLOW METAL AND FINISHED PER FINISH SCHEDULE, 1 EA. PEMKO 171A X 42" X DOUBLE NOTCH CUT ENDS X THRESHOLD 1 EA. PEMKO 346C X 46" AL OVERHEAD RAIN. DRIP X SECURITY TORX SD/ST SMS 2. SEE HARDWARE SCHEDULE FOR HARDWARE AND 1 EA. PEMKO 221APK X 42" AL COMBINATION KICK PLAT &DOOR SHOE X TORX MANUFACTURERS. 1 SET. P8512 X CONT. PERIMETER WEATHER SEAL (BLACK) 1 EA. INSTALLATION KIT (PER L ET) (2 PI 1 EA. CARDBOARD PACKAGING (2 PIECE BOX) 3. SEE SECTION 10A FOR TOILET STALL DOORS WHERE 1 EA. DELIVERED ON FULL LENGTH WOODEN PALLET APPLICABLE. GC TO PROVIDE AND INSTALL HOLD OPEN PERFORMANCE HARDWARE SET NO. 2: (BY YKK AP AMERICA INC.) 1. INSTALLATION: INSTALL IN ACCORDANCE WITH DOORS AND FRAMES MANUFACTURER'S INSTRUCTIONS. CAULK AROUND QTY PART # FINISH MODEL DESCRIPTION ABUTTING EDGES WITH CLEAR SILICONE. 1 49111DOR YB5N YKK AP #20D 3' x T O/P OFFSET PIVOTS, HBR RH 1 92115FTR YBSN 2" x 4-1/2" Tx 7' 0/P, FRAME, W/TRANSOM, RH SECTION 8C: STEEL DOORS AND FRAMES 1 49114DOP YBSN 20D 6' x 7' O/P, OFFSET PIVOTS, HBR PR 1 92118FTP YBSN 2" x 4-1/2" 6' x 7' O/P, FRAME, W/TRANSOM, PR GENERAL PROVISIONS 3 P61205 335 SM CLOSER W/BACK CHECK NHO PRIES 3 H1104SD 335 PUSH/PULL 1" DIAM. TYPE SC (9" OTC) 1. SCOPE: THE GENERAL CONDITIONS, SUPPLEMENTARY 3 H7707 YBSN 3-0 BOTTOM RAIL WEATHERSTRIP CONDITIONS, AND APPLICABLE PORTIONS OF DIVISION I OF THE 3 SD101 YBSN 10" BOTTOM RAIL UP TO 3' SPECIFICATIONS ARE PART OF THIS SECTION. 2 H4204 SD THUMBTURNS FURNISH AND INSTALL ALL STEEL DOORS AND FRAMES, COMPLETE STOCK LENGTHS WITH JAMB ANCHORS. QTY PART# FINISH LENGTH DESCRIPTION 11 BE91503 YBSN 24-0 HEAD / JAMB / VERTICAL MATERIALS 3 BE91512 YBSN 24-0 SHALLOW POCKET FILLER z BE91506 YBSN 24-0 HORIZONTAL 1. DOORS AND FRAMES BY PIONEER INDUSTRIES, INC., 2 BE91513 YBSN 24-0 4-1/2" SIDELITE BASE STEELCRAFT, OR CECO. 4 E91015 YBSN 24-0 GLASS STOP 2 BE91510 YBSN 24-0 SILL FLASHING ACCESSORIES DOOR FRAMES SHALL BE OF 16 GAUGE COLD ROLLED STEEL, OTY PART# LENGTH PKG DESCRIPTION THEY SHALL BE MITERED AND WELDED AT CORNERS. FRAMES 1 E20020 5OP/B SETTING BLOCK SHALL BE FURNISHED FACTORY- PRIMED AND SHALL HAVE 1 E20047 50P/B WATER DEFLECTOR THREE (3) "T" TYPE JAMB ANCHORS FOR EACH SIDE OF EACH 1 E20154 50P/B "W' SIDE BLOCK FOR DEEP POCKET FRAME. CAULK AROUND ALL ABUTTING EDGES WITH CLEAR 1 E10168 20P/B END DAM SILICONE. 2 E20052 50OP/B GLAZING GASKET DOORS SHALL BE CONSTRUCTED OF TWO (2) SHEETS OF 18 z PC1220 10oPlB #12 x 1-1/4" PHSMS TYPE AB GAUGE COLD ROLLED STEEL, WITH VERTICAL STIFFENERS NOT 1 E11015 5OP/B SHEAR BLOCK OVER 6" APART AND TOP AND BOTTOM EDGES REINFORCED PC1028 100P/B #10 x t-3/4"PHSMS TYPE AB HORIZONTALLY BY STEEL CHANNELS, JOINTS AT EDGES OF DOOR HARDWARE SET N0. 3: SHALL BE CONTINUOUSLY WELDED. DOORS SHALL BE SOUND DEADENED BY FILLING CORE WITH MINERAL WOOL INSULATION. 1-1/2 PR. HINGES K SCH A BEARING HINGES, 4-1/2" X 4-1/2" uszeD THEY SHALL BE THOROUGHLY CLEANED OF GREASE AND OTHER 1 EA. FLOOLATCR S T W/LOCK SCHLAGE SATURN X US28D IMPURITIES, FILLED FLUSH, AND GIVEN TWO (2) COATS OF 1 EA. FLOOR STOP BALDWIN #4000 FLOOR MOUNT 1 EA. KICKPLATE BURNS 8" X 30" X 8" 16GA. US628 BAKED -ON RUST RESISTANT METALLIC PRIMER. 1 EA. COAT HOOK JACKNOB #400 WITH RUBBER BUMPER 1 EA. CLOSER LCN 1460ALUMINUM CLOSER 2. SEE HARDWARE SCHEDULE FOR HARDWARE AND FOLLOWING ITEMS PROVIDED & INSTALLED BY G.C. MANUFACTURERS. Q� 1 EA. SIGN HANDICAP ACCESSIBILITY(ADA) DOOR & HARDWARE NOTES 1 EA, SIGN AS READ: DOOR #5 "MEN" 7" X 2" DOOR #6 "WOMEN" 7" X 2" A. HARDWARE SUPPLIER TO VERIFY STATE/LOCAL HANDICAPPED HARDWARE SET NO. 4: REQUIREMENTS FOR EXIT HARDWARE. B. COMPLETE SUBMITTALS ARE REQUIRED FOR APPROVAL PRIOR TO 1-1/2 PR. HINGES MCKINNEY BEARING HINGES, 4-1/2" X.4-1/2" US26D ANY ORDERING OR WORK. 1 EA. KICKPLATE BURNS 8" X 30" X 8" 16GA, US28D 1 EA. LATCHSETLOCK SCHLAGE SATURN X US26D 1 EA. CLOSER VIEWING wlNDow SER LCN 1480 ALUMINUM CLOSER C. ALL DOOR HARDWARE MUST HAVE A SHAPE THAT IS EASY TO GRASP 1 EA. CLOIN_ WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING, OR TWISTING OF THE WRIST TO OPERATE. HARDWARE SET NO. 5: D. IF PANIC HARDWARE IS REQUIRED BY CODE, G.C. TO FURNISH AND INACTIVE LEAF MANUAL FLUSH BOLTS, TOP AND BOTTOM, HAGER 282D, 26D INCLUDE PRICE ON BID. ACTIVE LEAF SCHLAGE F70-ELA826 SAT, PASSAGE LOCKSET E. SEAL BOTTOM OF WOOD DOORS. NOTES: STOREFRONT NOTES: 1, DOOR AND FRAME SHALL BE FULLY ASSEMBLED AND ALL HARDWARE SHALL BE INSTALLED BY SKILLED CRAFTSMEN AT THE FACTORY AND THE UNIT DELIVERED TO THE JOBSITE READY FOR INSTALLATIPM THE DOOR, HARDWARE AND G.C. TO UTILIZE HURRICANE RATED FRAMES AND GLAZING AS REQUIRED THE HARDWARE INSTALLATION SHALL CARRY MANUFACTURER'S 14-MONTH WAWRANTY W/ 24 HOUR SERVICE, ALUMINUM STOREFRONT FRAME: (TOLL FREE NUMBER TO BE DISPLAYED ON DOOR) BY YKK AP OF AMERICA. SYSTEM=YES 45 FS, 2"x 4 1/2" THERMAL SYSTEM FOR 1" INSULATED LOW "E" GLAZING. 2. H4101 FLUSH BOLT ON INACTIVE LEAF OF PAIR ONLY. FLORIDA PRODUCT APPROVAL #: FL12926.R2 DOORS: YKKAP 20D FLORIDA PRODUCT APPROVAL M FL5851.R5 1/2" EXT. PLYWOOD SCREW AWNING CLIP THROUGH 1/2" PVC SLEEVE AND SEAL BRONZE ALUMINUM AWNING FRAMING CONT. EIFS STARTER W/ DRIP EDGE SEALANT TO BACKER ROD (TYP.) WINDOW TYPES V QUIKSERV BP-7241E IP © DRIVE-THRU WINDOW NOA# 18-0814.01 FL-16711.R2 3 WINDOW SCHEDULE SIZE SERIES GLAZING FRAME REMARKS KEY (R.O.) R.0 �T MFR. MODEL TEMPERED DESCRIPTION PROFILE MATERIAL O 16-8" 6-8" YKK AP YES 45 FS TEMP. 1" INSULATED LOW "E" 1-3/4" X 4-1/2" ALUM FL12926.R2 © 10'-8" T-8" YKK AP YES 45 FS TEMP. 1" INSULATED LOW "E" 1-3/4" X 4-1/2" ALUM FL12926.R2 6'-0" 3'-5" QUIKSERV BP-7241 E IP TEMP. V INSULATED LOW "E" 2" X 4-1/2" ALUM FL16711.R2, NOA 18081401 OV-4" 2'-6" YKK AP YES 45 FS TEMP. 1" INSULATED LOW "E" 1-3/4" X 4-1/2" ALUM FL12926.R2 OE 6-41" 6-8" YKK AP YES 45 FS TEMP. V INSULATED LOW "E" 1-3/4" X 4-1/2" ALUM FL12926.R2 HEADER/BEAM - SEE STRUCTURAL DWGS. FOR SIZE AND LOCATION 1/4" SHIM ACOUST. CLG. TILE AND GRID WOOD TRIM. STAIN AND VARNISH TO MATCH CHAIR -RAIL SILICONE SEALANT STOREFRONT SYSTEM - INSTALLED PER MANUFACT. A SPECIFICATIONS DOOR / WINDOW HEAD DETAIL VINYL WALL COVERING- 1/2" GYPSUM TYP. BEARING PACK STUD II -i FOR WINDOW HEADER 1/2" EXT, PLYWOO II 1 1/4" RIGID INSULATIO L '11"I'zz ai rl,: EIFS MESH EMBEDDED 0 BASE COAT FINIS 1/4" CONT. EIFS STARTER AN CASING BEAD SYSTEM 2 DOOR / WINDOW JAMB DETAIL Scale:1-1/2"=V-0" CONT. CAULKING CONTINUOUS FLASHING UNDER WINDOW CONT. CAULKING CONTINUOUS FLASHING UNDER WINDOW ACCENT BAND [PAINT] 1 1/4" RIGID INSULATION CONT. EIFS STARTER TRACK CONT. FLASHING, FILLED W/ GROUT 15 lb. FELT MEMBRANE ON PLYWOOD BEHIND STONE SIMULATED STONE VENEER CLEAR PLASTIC CORNER GUARD SILICONE CAULK SEALANT TO BACKER ROD 1/4" SHIM STOREFRONT SYSTEM, INSTALLED PER MANUF. SPECIFICATIONS SEALANT TO BACKER ROD (TYPICAL) A2 3 WINDOW SILL / THRESHOLD DETAIL Scale: 1-1/2"=V-0" STRUCTURAL BEAM/HEADER. SEE STRUCTURAL DWGS SEALANT TO BACKER ROD (TYP.) 2x DOOR WOOD FRA 2x 2x STUD DOORJAMB WOOD FRAMING 2x STUD SHIM AS REQ'D. 20 GAUGE STAINLESS STEEL COVER (LENGTH OF WINDOW & EDGES SILL CAP BENT TO FIT CONT. `WOOD TRIM SILICONE SEALANT 1/4" SHIM STOREFRONT SYSTEM- 0 YKK YES-45-TU INSTALLED PER MANUF. SPECIFICATIONS I_ -_A =1S SYSTEM LICONE SEAL TO \CKER ROD (K AP 20D DOOR (STEM LICONE SEAL TO BACKER )D AINSCOTT PANEL AND WALL )VERING FINISHES EAR CORNER GUARD "' PLYWOOD SIMULATED STONE VENEER 15 LB. FELT MEMBRANE ON PLYWOOD SILICONE SEAL TO BACKER ROD YKK AP 20D DOOR SYSTEM SILICONE SEAL TO BACKER ROD WAINSCOTT PANEL AND WALL COVERING FINISHES CLEAR CORNER GUARD 1/2" PLYWOOD CONT. CAULKING STAINLESS STEEL 20 GA. OVER WD. SHIM EXTEND UNDER WINDOW FRAME AND BEHIND ELECTRIC EYE 1" EA. WAY 2x12 WD. BLOCKING ELECTRIC EYE WIRE FEED FROM ELECTRIC EYE TO WINDOW MOTOR THRU SILL BATT INSULATION DOUBLE 1/2" PLYWOOD BLOCKING C C SCHEDULED FLOORING, SEE ROOM FINISH SCHEDULE EIFS SYSTEM BLOCKING SILICONE TO BACKER ROD PLASTIC COMPONENTS #SB-1 BACKWRAP AND SEAL AT ALL OPENINGS EIFS SYSTEM 1/2" PLYWOOD )R 1 DOUBLE STUDS n j o J m 6 J UMy w 01 N N Z N O a J N CO H 2!0 W O w w C) o i� N W' Z N ^ r G a a �'na 0 w U O EL w w DO O F- O z W c' W 2 H w U LU w 2 DOUBLE HEADER Z (D 1/2" PLYWOODLU N BLOCKING p 1-1/4" DRYWALL SCREW @ 12" O.C. W _ H- ALUMINUM THRESHOLD SET IN SEALANT 0 J m _I W O_ 2 U N rn w o H � w O J to H O z a z W ZE 0 CC)O 0 w w w = o O o o ul H O H Ln H O Z W L D_ p O _J 0_ a Q U) C7 w W O w 5- I Q z W� DOUBLE w w CN STUDS ¢ 00 Yco H 1r 2 a a_ J (D I DR } � ] } SEA o r �p�E •N'I Co I co Lu w •:� L d w 9SZ 9! w ``�:•_ >_ Sj •. }ED J Ln w HAROLD DANIEL NUTTER III X FL. REG. 98913 ILL] W - RELEASE AT I COMMENT RESPONSE 03/2810 2 KITCHEN REVISION 06/26/19 3 OWNER REVISION 01/02/20 4 5 6 PROJECT NO. 2018-002 ISSUE DATE 12/21/18 DRAWN CHECKED GM HDH SHEET NO, Al BUILDING ENVELOPE WALLS WALL - SIMULATED STONE FINISH AND EIFS - U-VALUE = 0.056 WALL -393SF REAR WALL - 492 SF LEFT SIDE WALL - 1,133 SF RIGHT SIDE WALL - 1,128 SF t- I A C 0 WINDOW GLASS - U-VALUE = 0.50 FRONT WINDOW GLASS - 100 SF REAR N/A LEFT SIDE WINDOW GLASS - 115 SF RIGHT SIDE WINDOW GLASS - 66 SF ROOF SINGLE PLY BUILT-UP W/4" RIGID INSULATION U-VALUE = 0.032 TOTAL ROOF AREA - 2,265 SF DOORS GLASS - U-VALUE = 0.76 STEEL W/PAPER HONEY CONE CORE U-VALUE= 0.56 FRONT GLASS DOOR - 24.5 SF REAR I' STEEL DOOR - 28.0 SF LEFT SIDE N/A RIGHT SIDE GLASS DOOR - 56 SF SLAB ON GRADE TOTAL FLOOR AREA - 2,265 SF FLOOR PERIMETER - 225 LF r EXHAUST HOOD DUCT NOTES (BY G.C.) 1. ALL FRYER EXHAUST COLLARS AND EXHAUST DUCTWORK ARE SIZED TO MAINTAIN 2100 FPM EXHAUST AIR VELOCITY. ALL GREASE EXHAUST DUCTWORK SHALL BE CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH NFPA-96. GREASE EXHAUST DUCTWORK SHALL HAVE ALL SEAMS, JOINTS AND PENETRATIONS SEALED LIQUID TIGHT. 2. ALL HORIZONTAL RUNS OF GREASE DUCT, EXHAUST OR CONDENSATE SHALL SLOPE BACK TOWARD THE HOOD, GRILLE OR DRAIN AT A SLOPE OF 1" PER FOOT. PROVIDE A RESIDUE TRAP AT THE BASE OF EACH VERTICAL RISER. 3. THE MECHANICAL CONTRACTOR IS TO PROVIDE CLEANOUTS, PER DETAILS, IN GREASE EXHAUST DUCTWORK AT A MINIMUM OF 10' INTERVALS, AT EACH CHANGE OF DIRECTION AND AT EACH RESIDUE TRAP. 4. THE DISCHARGE OF THE GREASE EXHAUST FAN SHALL BE UPWARD AND A MINIMUM OF 40" ABOVE THE ROOF SURFACE AND A MINIMUM OF 10' FROM ANY OUTSIDE AIR INTAKE. 5. ALL GREASE EXHAUST DUCTS SHALL HAVE RADIUSED ELBOWS. EXHAUST DUCT PROTECTION: 6. GREASE EXHAUST DUCT SHALL BE CARBON STEEL 16 GAUGE WELDED DUCTS PER NFPA-96 PROTECTED WITH THE FOLLOWING: 1" AIR SPACE FROM DUCT TO 22 GA SHEET METAL COVERED WITH 1" MINERAL WOOL AND WIRE MESH SECURED TO COMBUSTIBLES WITH 1" NON COMBUSTIBLE SPACERS TO REDUCE CLEARANCE TO COMBUSTIBLES TO 3" PER NFPA 96 A-1-3.2. OPTIONAL DUCT PROTECTION: USE FIRE MASTER GREASE DUCT FIRE PROTECTION SYSTEM BY "THERMAL CERAMICS" WHICH OFFERS ZERO CLEARANCE TO COMBUSTIBLE & 2 HR. RATING. EXHAUST HOOD NOTES 1. THE FOLLOWING EQUIPMENT SHALL BE SUPPLIED BY OWNER AND INSTALLED BY THE MECHANICAL CONTRACTOR. A. STAINLESS STEEL HOODS AS SPECIFIED PRE PIPED FOR FIRE PROTECTION SYSTEM, AND CEILING CLOSURE STRIP. B. EXHAUST FANS AND CURBS EXCEPT RESTROOM EXHAUST FAN AND CURB. 2. THE MECHANICAL CONTRACTOR SHALL RECEIVE THE ABOVE EQUIPMENT, UNCRATE, BE RESPONSIBLE FOR REPORTING DAMAGE RECEIVED DURING SHIPMENT, AND BE RESPONSIBLE FOR LOSS OR DAMAGE TO THE ABOVE EQUIPMENT ONCE RECEIVED ON THE JOB. 3. EXHAUST HOODS PROVIDED WILL MEET OR EXCEED THE FOLLOWING REQUIREMENTS: - NSF # 1362 BEAR THE NSF SEAL OF APPROVAL - U.L. CLASSIFICATION # 24N1 - MEET OR EXCEED NFPA # 96, 1998 EDITION - 2006 IMC THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A SET OF SHOP DRAWINGS FROM THE HOOD MANUFACTURER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING THE HOOD MANUFACTURER OF ANY LOCAL CODES WHICH WILL AFFECT THE HOOD MANUFACTURE OR INSTALLATION. 4. THE HOOD MANUFACTURER WILL PROVIDE PRE -PIPED AUTOMATIC FIRE CONTROL SYSTEMS FOR THE FRYER HOOD INCLUDING FIRE CONTROL CABINETS - AND FURNISH A 2 POLE MICRO SWITCH FURNISHED FOR EQUIPMENT SHUT OFF TO BE HOOKED UP BY G.C. THE HOOD MANUFACTURER WILL BE RESPONSIBLE FOR FINAL INSTALLATION AND INSPECTIONS OF THE HOOD FIRE EXTINGUISHING SYSTEM. - COMPLETE EXTINGUISHING SYSTEM BY HOOD MANUFACTURER. 5. THE PLUMBING CONTRACTOR SHALL INSTALL THE MECHANICAL GAS VALVE IN ACCORDANCE WITH THE PLUMBING DRAWINGS. THE VALVE WILL BE PROVIDED TO HIM BY THE HOOD SUPPLIER. VERIFY WITH LOCAL AUTHORITIES. 6. THE ELECTRICAL CONTRACTOR SHALL PROVIDE WIRING IN ACCORDANCE WITH THE "HOOD WIRING DIAGRAM" SHEET M3. SECTION 15B - HEATING, VENTILATION, AIR CONDITIONING AND REFRIGERATION GENERAL PROVISIONS 1. SCOPE: PROVIDE ALL LABOR, MATERIAL, AND EQUIPMENT IN ACCORDANCE WITH THESE SPECIFICATIONS AND THE ACCOMPANYING DRAWINGS TO PROVIDE A COMPLETE AND PROPERLY OPERATING HEATING, VENTILATING, AIR CONDITIONING, AND REFRIGERATION SYSTEMS FOR THE BUILDING. WORK UNDER THIS SECTION INCLUDES, BUT IS NOT NECESSARILY LIMITED TO: A. FURNISH AND INSTALL THE FOLLOWING: ROOFTOP UNITS AND CURBS DUCT INSULATION AND DUCT WORK FOR HVAC C SYSTEMS DIFFUSERS, GRILLES, AND PLENUM BOXES CONTROL PANEL AND CONTROL WIRING B. INSTALL THE FOLLOWING: - EXHAUST FANS, HOODS, AND DUCTS FOR VENTILATION OF COOKING EQUIPMENT - ICE MACHINE AIR COOLED CONDENSER ON ROOF 2. GENERAL REQUIREMENTS: ALL WORK UNDER THIS CONTRACT SHALL BE ACCOMPLISHED IN STRICT ACCORDANCE WITH FEDERAL, STATE, AND LOCAL CODES. WHERE THESE PLANS AND SPECIFICATIONS ARE IN CONFLICT WITH SUCH CODES, THE CODES SHALL GOVERN. PAY FOR AND OBTAIN NECESSARY CONSTRUCTION PERMITS AND CERTIFICATES OF INSPECTION. NOTE: WHERE ENERGY CALCULATIONS ARE REQUIRED, THESE SHALL BE PREPARED BY THE G.C. AND SUBMITTED TO AFC'S AREA DEVELOPMENT DEAPARTMENT FOR APPROVAL PRIOR TO ANY CONSTRUCTION. A. COORDINATION: COORDINATE WORK WITH OTHER TRADES. LOCATIONS SHOWN ARE APPROXIMATE. REFER TO THE ARCHITECTURAL PLANS FOR EXACT MEASUREMENTS IN THE PLACEMENT OF EQUIPMENT, FIXTURES, OUTLETS, ETC. WHERE THE LOCATIONS ARE NOT CLEAR, OBTAIN THE EXACT LOCATION FROM AFC'S ARCHITECTURE AND ENGINEERING DEPARTMENT AND FIELD VERIFY. THE PLANS DO NOT GIVE EXACT DETAILS AS TO ELEVATIONS AND LOCATIONS OF VARIOUS PIPES, FITTINGS, DUCTS, CONDUIT, ETC., AND DO NOT SHOW ALL OFFSETS AND OTHER INSTALLATION DETAILS WHICH MAY BE REQUIRED. MATERIALS AND PERFORMANCE 1. MATERIALS: ALL MATERIALS SHALL BE NEW AND OF THE QUALITY INDICATED BY THE SPECIFIED BRAND NAMES. SUBSTITUTIONS OF MATERIAL OF EQUAL QUALITY BY OTHER FIRST -LINE MANUFACTURERS MAY BE ACCEPTABLE PROVIDED A LIST OF SUCH SUBSTITUTIONS IS APPROVED IN WRITING BY AFC'S ARCHITECTURE AND ENGINEERING DEPARTMENT. A SUBSTITUTIONS LIST SHALL BE SUBMITTED IN TRIPLICATE FIVE (5) DAYS BEFORE THE CONTRACT IS TO BE LET. 2. NATIONAL ACCOUNTS: ROOFTOP HVAC EQUIPMENT, TOILET EXHAUST FANS, HVAC DUCT SYSTEMS, AND HVAC DIFFUSERS, GRILLS, AND PLENUM BOXES ARE AVAILABLE FROM NATIONAL ACCOUNTS INDICATED ON THE DRAWING COVER SHEET. INSTALL ALL EQUIPMENT IN ACCORDANCE WITH PLANS AND MANUFACTURERS' INSTRUCTIONS. NATIONAL ACCOUNTS REFER TO DIRECTORY 3. ROUTING OF DUCT SYSTEMS: COORDINATE ROUTING OF DUCT SYSTEMS WITH OTHERS, LINE UP WORK TRUE TO ADJACENT SPACES AND IN A WORKMANLIKE MANNER, AND USE STANDARD RADIUS 90 ELBOWS. WHERE REQUIRED, DUCTWORK IS TO BE STURDILY SUPPORTED AND SEPARATED IN ACCORDANCE WITH ASHRAE & SMACNA STANDARDS. 4. DUCTWORK FOR HVAC SYSTEM: A. GENERAL NOTES: (1) VOLUME DAMPERS SHALL BE INSTALLED AT BRANCH RUNOUTS WHERE INDICATED. (2) DUCT DIMENSIONS INDICATED FOR RTU#1 ARE INSIDE DIMENSIONS WITH NO INTERNAL DUCT LINER. DIMENSIONS FOR OTHER RTU-2 ARE INSIDE DIMENSIONS SIZED WITH V INTERNAL DUCT LINER. (3) DUCT WORK SHALL BE BUILT IN ACCORDANCE WITH ASHRAE AND SMACNA STANDARDS. (4) USE 90 DEG. TURNING VANES IN ALL ELBOWS WHERE INDICATED ON THE DRAWINGS. VANES TO BE PROPERLY SPACED IN ACCORDANCE WITH ASHRAE AND SMACNA. (5) DUCT BOARD IS NOT ALLOWED. B. METAL DUCT WORK: (1) DUCT WORK SHALL BE CONSTRUCTED OF NEW GALVANIZED PRIME GRADE STEEL SHEETS. (2) THE GAUGES OF METAL TO BE USED AND THE CONSTRUCTION AND BRACING OF JOINTS SHALL BE IN ACCORDANCE WITH ASHRAE AND SMACNA STANDARDS. (3) METAL DUCT SHALL BE SUPPORTED FROM BUILDING STRUCTURE ON STRIP HANGERS NOT OVER 8'-0" APART. C. EXTERNAL DUCT WRAP FOR RTU #1 (KITCHEN UNIT): (1) INSULATE EXTERIOR OF ALL METAL MAIN SUPPLY ANDRETURN DUCTS WITH 2" THICK FIBERGLASS, 3/4 LB.DENSITY, BLANKET INSULATION WITH FOIL BACKING ANDUL LABELED. (2) INSULATION SHALL HAVE A FLAME SPREAD OF TWENTY FIVE(25) OR LESS AND A SMOKE DEVELOPED RATING OF FIFTY(50) OR LESS. (3) INSULATION SHALL BE OWENS-CORNING FRK25 OR EQUAL. (4) INSULATION SHALL BE SPOT GLUED ON 6" CENTERS, AND LIGHTLY LAPPED WITH 2" WIDE VAPOR BARRIER PRESSURE - SENSITIVE TAPE. (5) DUCT WRAP SHALL BE INSTALLED IN A NEAT AND COMPETENT MANNER WITH ALL EDGES COVERED WITH APPROVED METALLIC DUCT TAPE TO VAPOR -PROOF THE ENTIRE DUCT. D. FLEX CONNECTORS/FLEX DUCT: (1) FLEX CONNECTORS SHALL BE CERTAFLEX PUNCHLINE 25 WITH A R-6 RATING AND 1 1/2" THICK INSULATION. (2) CERTAFLEX PUNCHLINE 25 MEETS OR EXCEEDS IMC NFPA 90A-90B, SBCCI (8297), AND UL 181 CLASS 1. (3) THE ENDS OF FLEX CONNECTORS SHALL BE TRIMMED SQUARELY PRIOR TO INSTALLATION. (4) COLLARS AND SLEEVES SHALL BE INSERTED INTO FLEXIBLE DUCT A MINIMUM OF V BEFORE FASTENING. (5) FLEXIBLE CONNECTORS SHALL BE SECURED TO THE SLEEVE OR COLLAR USING A DRAW BAND. IF THE DUCT COLLAR EXCEEDS 12" DIAMETER THE DRAW BAND MUST BE POSITIONED BEHIND A BEAD ON THE METAL COLLAR. (6) INSULATION AND VAPOR BARRIERS PRESENT ON ALL FLEX CONNECTORS SHALL BE FITTED OVER THE CORE CONNECTION AND SHALL BE SUPPLEMENTALLY SECURED WITH A DRAW BAND AND TAPED, 5. TEMPERATURE SETTINGS: AT CONCLUSION OF PROJECT, SET POINTS SHALL BE APPROXIMATELY COOLING 78 DEGREES F/ HEATING 68 DEGREES F, AND INSTRUCT OWNER HOW TO RESET. 6. ROOF CURBS: CURBS TO BE FURNISHED BY ASSOCIATED EQUIPMENT MANUFACTURER AND INSTALLED IN ACCORDANCE WITH DETAILS ON SHEET M2 AND IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. COORDINATE WITH ROOF CONTRACTOR. RTU'S SHALL BE INSTALLED SUCH THAT ROOF DECK IS COMPLETE AND CONTINUOUS BENEATH UNITS, AND SHALL BE CUT ONLY FOR UNIT SUPPLY AND RETURN OPENINGS. SPACE BETWEEN BOTTOM OF RTU'S AND ROOF DECK SHALL BE FILLED WITH ACCOUSTICAL INSULATION. 7. TESTING AND ADJUSTING OF HVAC SYSTEM: UPON COMPLETION OF THE INSTALLATION, THE PROJECT SHALL BE TESTED AND ADJUSTED AS FOLLOWS: A. ADJUST FAN DRIVES TO ACHIEVE REQUIRED AND RATED CFM AND SPECIFIED RPM. B. ADJUST TEMPERATURE AND FAN CONTROL SEQUENCE. C. ADJUST THE ENTIRE INSTALLATION AS TO MINIMIZE NOISE AND VIBRATION FROM FANS, COMPRESSORS, STARTERS, AND RELAYS. D. ELIMINATE ANY DUCT PULSATION BY USE OF STIFFENERS OR ADDITIONAL SUPPORTS AS REQUIRED. E. CORRECT ANY EQUIPMENT OR COMPONENT WHICH IS GENERATING OBJECTIONABLE NOISE IN THE OPINION OF THE OWNER OR BY LOCAL AUTHORITIES, F. BALANCE EXHAUST AND OUTSIDE AIR TO QUANTITIES INDICATED ON THE PLANS. REFER TO BUILDING AIR BALANCE SCHEDULE. G. PROVIDE OWNER TWO (2) COPIES OF A WRITTEN AIR BALANCE REPORT INDICATING ALL FINAL EXHAUST, SUPPLY, AND OUTSIDE AIR FLOWS. (CONTRACTOR SHALL PROVIDE ALL TOOLS AND TEST EQUIPMENT NECESSARY FOR BALANCING ALL HVAC AND EXHAUST AIR SYSTEMS. A "DIGITAL" ANEMOMETER MODEL DA 4000 WITH A 275 PROBE IS RECOMMENDED FOR MEASURING HOOD EXHAUST.) 8. REFRIGERANT PIPING: PIPING TO BE HERMETICALLY SEALED AND PRE- CHARGED TUBING WITH O-RINGS SEALS AS PROVIDED BY THE REFRIGERANT EQUIPMENT MANUFACTURER WITH ADEQUATE FOAMED NEOPRENE INSULATION. CHARGE AND TEST SYSTEM FOR LEAKS. ENSURE AGAINST LEAKS AND PROPER EVACUATION PRIOR TO CHARGING. DO NOT EXCEED MANUFACTURER'S RECOMMENDED CHARGE SCHEDULE. SLEEVES THROUGH WALL OF FREEZER/COOLER SHOULD BE RUBBER OR NEOPRENE. 9. CONTROLS: FURNISH AND INSTALL AS INDICATED ON DRAWINGS. FURNISH AND INSTALL ALL CONTROL WIRING AND CABLES FROM HVAC UNITS, TEMPERATURE SENSORS, PHOTOCELL, AND CONTACTOR PANEL AS REQUIRED. ROUTE CONTROL WIRING IN RACEWAY IN EQUIPMENT IF PROVIDED. 10. COOKING EXHAUST FANS AND DUCTWORK: INSTALL ALL COOKING EXHAUST FANS IN ACCORDANCE WITH THE PLANS AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. COOKING EXHAUST FANS ARE SUPPLIED BY OWNER. VENTILATOR EXHAUST DUCT SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 96. 11. CLEANUP: AFTER COMPLETION OF THE WORK BEFORE FINAL INSPECTION CLEAN HVAC EQUIPMENT. 12. FILTERS: PROVIDE CLEAN SET OF FILTERS FOR EACH HVAC UNIT WHEN TURNED OVER TO THE OWNER. 13. HVAC OPERATOR'S MANUAL AND DIAGRAMS: A. PROJECTS PARTICIPATING IN THE NATIONAL ACCOUNTS PROGRAM SHALL FOLLOW THE PROCEDURE OUTLINED IN THE NATIONAL ACCOUNT. B. PROJECTS, NOT PARTICIPATING IN THE NATIONAL ACCOUNT SHALL FOLLOW THE FOLLOWING PROCEDURE: PREPARE IN DUPLICATE A MANUAL DESCRIBING THE PROPER MAINTENANCE AND OPERATION OF THE SYSTEM. THIS MANUAL SHALL NOT CONSIST OF STANDARD FACTORY -PRINTED INSTRUCTIONS, ALTHOUGH THESE MAY BE INCLUDED, BUT SHALLBE PREPARED TO DESCRIBE THIS PARTICULAR PROJECT. THE MANUALS SHALL BE BOUND, INDEXED, DATED, AND SIGNED BY THE GENERAL CONTRACTOR. ONE (1) COPY SHALL BE SENT TO AFC'S ARCHITECTURE AND ENGINEERING DEPARTMENT AND THE OTHER TO THE OWNER. QUALIFIED REPRESENTATIVES OF THE AIR CONDITIONING CONTRACTOR SHALL MEET WITH THE DESIGNATED REPRESENTATIVE OF THE OWNER. THE OWNER'S REPRESENTATIVE SHALL BE INSTRUCTED IN THE PROPER OPERATION AND MAINTENANCE OF THE HVAC AND CONTROL SYSTEM. 14. GUARANTEE: MATERIALS AND WORKMANSHIP SHALL BE GUARANTEED FOR ONE (1) YEAR FROM DATE OF COMPLETION. IN ADDITION, ALL REFRIGERATION COMPRESSORS SHALL BEAR A NON -PRORATED 5-YEAR FACTORY WARRANTY, AND ALL EXTENDED WARRANTIES. 15. SERVICE ACCESS: PROVIDE SERVICE ACCESS AS REQUIRED IN MANUFACTURER'S INSTALLATION INSTRUCTIONS. IF SUCH ACCESS IS NOT AVAILABLE, NOTIFY OWNER AND ATTEMPT TO SEE IF NECESSARY CHANGES CAN BE WORKED OUT WITH OTHER TRADES. IF NOT, DO NOT INSTALL EQUIPMENT WHICH DOES NOT MEE MANUFACTURER'S REQUIREMENTS FOR ACCESSIBILITY IN NO CASE BID, SUBMIT, OR INSTALL EQUIPMENT IN ITUATIONS THAT DO NOT MEET THE MANUFACTURER'S WARRANTY REQUIREMENTS. 16. ENVIRONMENTAL CORROSION PROTECTION. CONDENSER, COOLING/HEATING COILS: A. REQUIRED FACTORY DIPPED COATING WITHIN ONE MILE OF ANY SALTWATER BODY. FACTORY PRE -COAT WITHIN ONE TO FIVE MILES OF ANY SALT WATER BODY. HVAC SEQUENCE OF A OPERATIONS RTU-1,2,3 MOTORIZED OA DAMPER SHALL BE INTERLOCKED WITH KITCHEN HOOD EXHAUST FANS EF-1,2,3 AND SHALL BE IN OPEN POSITION WHEN IN OPERATION. RTU EVAPORATOR FANS SHALL RUN CONTINUOUSLY. RESTROOM EXHAUST FAN EF-4 SHALL BE CONTROLLED BY LIGHT SWITCH / MOTION SENSOR. GENERAL NOTES 1. MECHANICAL CONTRACTOR SHALL VERIFY THAT ALL EQUIPMENT, AS SHOWN ON THESE DRAWINGS, WILL NOT CONFLICT WITH ANY DRAINS, SCUTTLES, JOINTS, VENTS, ETC. 2. ALL ROOF MOUNTED EQUIPMENT AND PENETRATIONS SHALL BE FLASHED A MINIMUM OF 12" ABOVE THE ROOF. PROVIDE AMPLE CURBS OR PIPE SEALS FOR ELECTRICAL CONDUITS WHICH SUPPLY MECHANICAL EQUIPMENT. 3. ALL OUTSIDE AIR INTAKES SHALL BE A MINIMUM OF 10'-0" FROM ANY EXHAUST FAN OR PLUMBING VENT. REFER TO ROOF PLAN. 4. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ADMINISTERING ALL WARRANTIES ON EQUIPMENT WHICH HE INSTALLS. THIS INCLUDES ALL CONDENSERS, REFRIGERANT LINES, AND OTHER ITEMS FURNISHED BY OTHERS AS WELL AS THOSE FURNISHED BY HIM. 5. CONDENSATE DRAINAGE FROM ROOF TOP HVAC UNITS SHALL BE TRAPPED. REFER TO ROOF PLAN 6. PROVIDE VIBRATION ISOLATION DEVICES AND FLEXIBLE CONNECTIONS TO ALL MOVING MACHINERY. 7. ALL DUCT DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. 8. MECHANICAL CONTRACTOR SHALL COORDINATE ALL DUCT AND DIFFUSER LOCATIONS WITH LIGHTING LAYOUTS AS REQUIRED. 9. THE CONTRACTOR SHALL PROVIDE COMPLETE INFORMATION AND COOPERATION TO THE OTHER CONTRACTORS AND TRADES AS REQUIRED FOR COMPLETION AND COORDINATION OF THE COMPLETE PROJECT. 10. THIS CONTRACTOR SHALL COORDINATE WITH THE GENERAL CONTRACTOR AND OTHER TRADES, ALL REQUIRED OPENINGS AND EXCAVATIONS. ALL REQUIRED OPENINGS IN FOUNDATIONS, FLOORS, WALLS AND ROOFS SHALL BE DESIGNED INTO THE STRUCTURE INITIALLY BY THE USE OF SLEEVES, CURBS, ETC. CUTTING AND PATCHING SHALL BE HELD TO A MINIMUM. 11. THERMOSTATS SHALL BE LOCATED GENERALLY AS SHOWN BUT THEIR EXACT LOCATION SHALL BE FIELD COORDINATED TO AVOID INTERFERENCE WITH WALL MOUNTED ITEMS. MOUNT 42" AFF. 12. THE G.C. SHALL PERFORM AND BE RESPONSIBLE FOR ALL REFRIGERATION WORK REQUIRED FOR THE WALK-IN COOLER, WALK-IN FREEZER. G.C. SHALL ALSO BE RESPONSIBLE FOR START UP. 13. THE GENERAL CONTRACTOR SHALL PERFORM AND BE RESPONSIBLE FOR ALL REFRIGERATION WORK REQUIRED FOR THE ICE MACHINES. ALL HIS WORK SHALL BE DONE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.TACT THEEQUIPMENT CON SUPPLIERS TO OBTAIN ALL NECESSARY INFORMATION TO PERFORM THE REFRIGERATION WORK. G.C. SHALL ALSO BE RESPONSIBLE FOR ARRANGING FACTORY AUTHORIZED START-UP AND ADJUSTMENT ON THE ICE MACHINES. 14. MECHANICAL CONTRACTOR TO INSULATE BACKSIDE OF ALL DIFFUSERS. 15, TRANSITION ALL DUCTS AS REQUIRED TO ATTACH TO EQUIPMENT, 16. OFFSET RETURN AIR DUCTS FOR ROOF TOP AC UNITS TO AVOID FRAMING AS REQUIRED. 17. ALL DAMAGED COIL FINS SHALL BE COMBED STRAIGHT. HOOD OPERATION 0 - ONCE ALL REQUIRED CONNECTIONS HAVE BEEN COMPLETED AS INDICATED ON THE SCHEMATIC, POWER CAN BE APPLIED TO THE PANEL. THE ECPM03 CIRCUIT BOARD AND LCD SCREEN WILL POWER UP AND BEEP. -THE LCD SCREEN (CASHMI) HAS (4) BUTTONS WITH THE FUNCTION DISPLAYED ADJACENT TO THE BUTTON. LIGHTS AND FANS ARE SHOWN ON THE BOTTOM 2 BUTTONS. AN EMPTY BOX AROUND FANS OR LIGHTS MEANS THAT THESE ARE OFF. A DARK BOX AROUND THE FANS OR LIGHTS MEANS THAT THESE ARE ON. - A THERMISTOR WILL BE INSTALLED IN EVERY HOOD EXHAUST RISER. A 2-WIRE PLENUM RATED THERMISTOR CABLE (18 GA TYPICAL), RUN IN CONDUIT, SHOULD BE USED TO WIRE THE SENSORS BACK TO THE CONTROLLER. - A ROOM TEMPERATURE SENSOR IS PROVIDED WITH THE PANEL AND SHOULD BE INSTALLED IN A SAFE LOCATION, FREE OF INFLUENCE FROM EXTERNAL HEAT SOURCES. IT SHOULD BE INDICATIVE OF THE AVERAGE TEMPERATURE AWAY FROM THE APPLIANCES. SEQUENCE OF OPERATION FANS ON: TURN ON THE COOKING APPLIANCES AND ALLOW THEM TO REACH IDLE TEMPERATURE. THE FANS SHOULD AUTOMATICALLY BE ENERGIZED AS THE COOKING APPLIANCES HEAT UP. THE FACTORY SET ACTIVATION POINT FOR DUCT TEMPERATURE OVERRIDE OF THE FAN SWITCH IS 100 ABOVE KITCHEN ROOM TEMPERATURE. THIS FUNCTION ALLOWS THE SYSTEM TO MEET THE REQUIREMENTS OF IMC 507.2.1.1, WHICH REQUIRE EXHAUST FANS TO ACTIVATE WHEN COOKING IS OCCURRING. LIGHTS WILL AUTOMATICALLY BE TURNED ON AS WELL. LIGHTS CAN BE TURNED ON AND OFF MANUALLY BY PRESSING THE LIGHTS BUTTON. FANS OFF: IF THE SYSTEM WAS IN AUTOMATIC OPERATION, THE FANS WILL TURN OFF WHEN THE DUCT TEMPERATURE GOES BELOW THE ACTIVATION POINT MINUS THE TEMPERATURE HYSTERESIS OF 2 DEGREES. FOR EXAMPLE, IF THE ACTIVATION TEMPERATURE IS AT 850F AND TEMPERATURE HYSTERESIS IS SET TO 2°F, THEN THE FANS WILL TURN OFF AT 83°F NOTE: THE HYSTERESIS TIMER, FACTORY SET AT 30 MINUTES, IS USED TO PREVENT THE FANS FROM CYCLING ON AND OFF TOO OFTEN DUE TO SMALL APPLIANCES GENERATING JUST ENOUGH EAT TO TURN ON THE FANS BUT NOT ENOUGH TO KEEP THEM ON FOR A LONG TIME. THE HYSTERESIS TIMER WILL MAINTAIN THE FANS ON AFTER THEY HAVE BEEN ACTIVATED BY TEMPERATURE FOR A MINIMUM TIME SET BY THIS TIMER, EVEN IF THE TEMPERATURE IN THE DUCT COOLS BACK DOWN. HVAC SYMBOL LEGEND AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE BTU BRITISH THERMAL UNIT CD CEILING DIFFUSER CFM CUBIC FEET PER MINUTE CU CONDENSING UNIT EAT ENTERING AIR TEMPERATURE EDH ELECTRIC DUCT HEATER FD FLOOR DRAIN HP HORSEPOWER KW KILOWATT LAT LEAVING AIR TEMPERATURE CA OUTSIDE AIR AC PACKAGE AIR CONDITIONING UNIT RPM REVOLUTIONS PER MINUTE RTU ROOFTOP UNIT UP DN THRU Ip�IC71 ® I�I_Y y SUPPLY AIR (SA) DUCTWORK UP DN THRU = J ® RETURN AIR (RA) DUCTWORK UP DN THRU � y 14 EXHAUST AIR (EA) DUCTWORK WB WET -BULB 1 iT i WALL MOUNTED THERMOSTAT FOR UNIT INDICATED REMOTE DUCT TEMPERATURE SENSOR FL FUSIBLE LINK DUCT SECTION, POSITIVE PRESSURE, FIRST FIGURE IS ARROW SIDE ® DUCT SECTION, EXHAUST ® DUCT SECTION, NEGATIVE PRESSURE, RETURN I CHANGE OF ELEVATION RISE (R) DROP (D) e-I FLEXIBLE CONNECTION TRANSITION I I TURNING VANE O . DUCT MOUNTED SMOKE DETECTOR VOLUME DAMPER, SINGLE LEAF, MANUAL VOLUME DAMPER, OPPOSED BLADE, MANUAL �3 MANUAL SPLITTER STANDARD BRANCH, SUPPLY OR RETURN, NO SPUTTER STANDARD BRANCH, ADJUSTABLE EXTRACTOR ® CEILING DIFFUSER ® CEILING RETURN cY CEILING EXHAUST t® T UC UNDERCUT DOOR, CFM AND 125 AIR FLOW AS INDICATED CFM RADIUS ELBOW - INSIDE RADIUS MINIMUM ONE HALF DUCT WIDTH SQUARE TO ROUND TRANSITION • - DUCT WIDTH -- -- DUCT HEIGHT 12X12 DUCT DIMENSION KEY NOTE: MECHANICAL CONTRACTOR TO VERIFY TRUSS CLEARANCE'S PRIOR TO COMMENCEMENT OF WORK. APPROVED HVAC NATIONAL ACCOUNT APPROVED VENDORS: CARRIER TRANE O w U O a w G_ Lu m O F_ F- O z w G✓ r Lu _ F_ Lu U z Lu z CD to w 0 w _ 0 z F_ F_ 2: Lu U O 0 Lu w O F_ U) I- _ CD w o_ O D_ d D' Lu _ F- O J J I z ! 0 D_ r tZ O U m F_ m w D_ Lu m W G' r J Cn m w tY a x III m J > N N co w z E U .E a W Lu F__ Lu = Z of Z Q Lu U o J m I1� L J W U M �n w W Z W N 0 Up V M � (7 w i-- w Z U o N 2 Z oc N o �i N Q a QN ^ 0'N N d L J Q U) U Z Lu J Q m J (n Lli 0- W J ¢ U rn Q Lu LU o IF F- L Q Q Z C)O A W = � , � Y ¢ J x F- =)J Q m popeYes Z LLJ ZE Of O U) Cn w J Q m v M Lu � N LL ui 5 N a � O 0- J o � o w w w x z _O Q U IL U Lu LU LLJ U) H M Q z w G JCHC 0 0��b8wdc�AP � !• N 44.E s t • • m Q o STA E OF s <` 0RI0P ROB��W FLORIDA 3 RCLCAOC UAIC COMMENT RESPONSE 1 03/28/19 2 KITCHEN REVISION 06/26/19 3 OWNER REVISION 01/02120 a 5 s PROJECT NO. 2018-002 ISSUE DATE 12/21/18 DRAWN CHECKED CS CS ALI S ---- A L-75 J-8 00 725 A- 000 6 ' L_75 1 CO2 RRU O� 14" 18"0 - - 12"0 6"0 EF 4 FA 60a III I D F-15o 5-- O I I I! G-50 G-50 RTU-1 I i - -- 2 0� 6"0 _ 12I'D - - ' TYPE 2"O _ 2 FLOUR ODD EA-400 - A 600 1' C 600 n O _ -- - • ORTU-3 E-600 7 E 600 S/S HOOD1 s1 1 5 / EF-3 EF-1 10 120 AV I - 1 EFEF-2 B-600 0- TYPEI T z FRYER GREASE HOOD B- T 600 1 12"0 5 - • - - KEYED NOTES 0 9"X 9" -16 GAUGE CARBON STEEL GREASE EXHAUST DUCT CONTINUOUSLY WELDED LIQUID TIGHT WITH CLEAN OUTS AND ACCESS PANELS INSTALLED AT ANY REQUIRED FIELD OFFSETS. SLOPE DUCT TOWARDS HOOD IF ANY HORIZONTAL OFFSETS ARE REQUIRED. COMPLY STRICTLY TO NFPA 96 AND LOCAL CODES. COORDINATE DUCT CONNECTION SIZE, TRANSITION, AND LOCATION WITH HOOD MANUFACTURER. REFER TO "0" CLEARANCE TO COMBUSTIBLES DETAIL ON SHEET M-3 , VERIFY LOCATIONS OF HOOD TO TARGET EXHAUST FAN WITH MOST RECENT KITCHEN EQUIPMENT PLANS. O T-2900 PROGRAMMABLE THERMOSTAT WITH LOCKING COVER, MOUNT T-STATS 42" A.F.F. IN MANAGERS OFFICE ABOVE DESK AND BELOW CABINET. SEAL WALL OPENINGS WITH CAULK. O3 REMOTE SENSOR 66" A.F.F. ON WALL NEAR LOCATION INDICATED THIS SHEET. AUDIO-VISUAL ANNUNCIATOR TIED INTO SMOKE DETECTOR. COORDINATE LOCATION ON SITE WITH G.C. AND EQUIPMENT. AVOID SOURCES OF HEAT. SEAL WALL OPENINGS WITH CAULK. MOUNT SENSORS AND AVS FOR RTU-2 AS PER LEADERS SHOWN ON FLOOR PLAN. O4 10X10 PLENUM DROP WITH END CAP DOWN FROM EF-4 CURB, CONNECT 6" RIND. SMACNA PIPE - SEE DETAIL ON M2. O5 SHIM CURBS ON ROOF IN ORDER TO MAKE TOP OF CURBS LEVEL. SEE DETAIL ON SHEET M-2. 06 FIRE ALARM CONTROL PANEL O SMACNA GRADE MTL. PIPE UP TO 12" SQ. PLENUM. STRAP & TAPE ALL JOINTS PROPERLY. NO SCREWS. HOOD HAS BEEN SELECTED TO CONTROL FLOUR PARTICLES FROM DRIFTING IN KITCHEN SPACE. O8 HOOD FIRE SUPPRESSION PULL STATION O9 HOOD CONTROL PANEL - MOUNT BELOW SHELF 10 HOOD FIRE SUPPRESSION CABINET AND TANKS NCA HVAC EQUIPMENT PACKAGE EQUIPMENT SHALL BE PURCHASED THROUGH NCA. PRICING FOR THE FOLLOWING PACKAGE OF EQUIPMENT AND ACCESSORIES CONTACT THE NCA GROUP MARKETING DEPARTMENT TOLL -FREE AT (877) 530-0078. HEATING COOLING EQUIPMENT PACKAGE INCLUDES SCHEDULED ROOFTOP UNITS WITH ACCESSORIES AS SPECIFIED ON THESE PLANS. FAN PACKAGE BY OTHERS. AIR DEVICE PACKAGE INCLUDES ALL AIR DEVICES PER PLANS. SQUARE TO ROUND TRANSITIONS PROVIDED WHERE REQUIRED. CURB PACKAGE INCLUDES ONE-PIECE, FULLY WELDED NCA PLENUMIZED AND ALL NEW FAN CURBS. EXHAUST HOOD PACKAGE EXHAUST FANS, HOODS, SHROUDS AND ANSUL SYSTEM BY OTHERS CONTROLS PACKAGE INCLUDES PRESET DIGITAL THERMOSTATS, THERMOSTAT WIRE, LOCKING COVERS, AND AS CODE REQUIRES SMOKE DETECTORS AND AUDIBLE -VISUAL DEVICES; NCA MASTER RELAY PANEL MY BE ORDERED IN LIEU OF ELECTRICAL PACKAGE PROVIDED BY CAPTIVE AIRE HOOD PLAN AND SPECIFICATIONS AS PER P.E. SEAL NCA SHALL VISIT THE SITE, AS AUTHORIZED, TO VERIFY THE PROFESSIONAL ENGINEER SEAL DESIGN UPON COMPLETION OF PROJECT. PLANS ARE NCA DESIGN COPYRIGHT 2007. AIR BALANCE INSTRUCTIONS FOR TYPE-1 HOOD INSTALLING CONTRACTOR IS RESPONSIBLE FOR HAVING A CERTIFIED, INDEPENDENT BALANCE COMPANY PERFORM A TEST AND BALANCE ON THE EXHAUST AND VENTILATION CaYSTEM. TEST AND BALANCE COMPANY MUST BE INDEPENDENT AND NOT ON THE HVAC INSTALLER6 STAFF, CONTRACTOR SHALL PROVIDE WRITTEN REPORT CERTIFYING SYSTEM BALANCE TO THE ARCHITECT AND OWNER. 'I CO2 2"0 AV ORTL A 550 )110 - -- 12"0 / --- J-800 "0 H-1725 0 . i 8"0 FLOOR PLAN - HVAC SCALE 114" = V - 0" WHEN PLOTTED 36" X 24" AIR BALANCE SCHEDULE TAG SUPPLY AIR OUTSIDE AIR RETURN AIR EXHAUST AIR BLDG. PRESSURE % OUTSIDE AIR RTU-1 3400 CFM 875 CFM 2525 CFM + 875 CFM 25 RTU-2 3400 CFM 875 CFM 2525 CFM + 875 CFM 25 RTU-3 3400 CFM 875 CFM 2525 CFM + 875 CFM 25 EF-1 --- --- --- 935 CFM - 935 CFM --- EF-2 --- --- --- 935 CFM - 935 CFM --- EF-3 --- --- --- 600 CFM - 600 CFM -- EF-4 -- --- 150 CFM - 150 CFM --- TOTAL 10200 CFM 1 2625 CFM 7575 CFM 2620 CFM + 5 CFM N/A FAN SCHEDULE UNIT NUMBER EF-1, EF-2 EF-3 EF-4 AREA SERVED FRYER HOOD BATTER STATION RESTROOM MANUFACTURER CAPTIVEAIRE CAPTIVEAIRE CAPTIVEAIRE MODELNUMBER DU85HFA DU12HFA DR10HFA A-550 VENTILATION CALCULATION 2017 FBC MECHANICAL, SIXTH CAFETERIA, FAST FOOD: BREATHING ZONE OUTDOOR AIRFLOW ZONE FLOOR AREA: 865 SQ FT OCCUPANT DENSITY: 100 PEOPLE PER 1,000 SQ FT PEOPLE OUTDOOR AIRFLOW RATE: T5 CFM PER PERSON AREA OUTDOOR AIRFLOW RATE: 0.18 CFM PER SQ FT Vbz = RP Pz + Ra Az Vbz = 7.5 (100/1,000 X 865) + (0.18 X 865) Vbz = 649 CFM + 156 CFM = 805 CFM RTU-3: OUTDOOR AIR REQUIRED = 805 CFM OUTDOOR AIR PROVIDED = 875 CFM RESTROOM EXHAUST 70 CFM PER WATER CLOSET OR URINAL (2) WATER CLOSETS X 70 CFM =140 CFM EF-3: EXHAUST REQUIRED = 140 CFM EXHAUST PROVIDED = 150 CFM KITCHEN EXHAUST 0.70 CFM PER SQUARE FOOT 0.70 X 990 SF = 693 CFM EF-1, EF-2, EF-3: EXHAUST REQUIRED = 693 CFM EXHAUST PROVIDED = 2,470 CFM Az Pz Rp Ra N •C •A CONSULTANTS/GROUP 4585 140TH AVE. NORTH, SUITE #1009 CLEARWATER, FLORIDA PHONE1877) 530-0078 CALL NCA MARKETING FOR PRICING NCA JOB# 16-1446 UP ON COMMENCEMENT OF ROUGH -IN AS SCHEDULED BY NCA CONSULTANTS THE AIR CONDITIONING CONTRACTOR IS TO REMAIN ON THE JOB SITE FULL TIME UNTIL THE ROUGH -IN IS 100%COMPLETE, THE GENERAL CONTRACTOR'S SITE SUPERINTENDENT WILL VERIFY. UPON COMMENCEMENT OF TRIM -OUT AS SCHEDULED BY NCA CONSULTANTS, THE AIR CONDITIONING CONTRACTOR IS TO REMAIN ON THE JOB SITE FULL TIME UNTIL THE TRIM -OUT IS 100%COMPLETE. THE GENERAL CONTRACTOR'S SITE SUPERINTENDENT WILL VERIFY. HVAC CONTRACTOR 1. THE HVAC CONTRACTOR SHALL INSTALL THE TYPE 1 FRYER HOOD LEVEL & AT THE PROPER LOCATION, GREASE RISERS, ALL HVAC ROOF CURBS RTU'S ALL HVAC DUCTWORK GRILLES HVAC CONTROLS AS NOTED INCLUDING SMOKE DETECTORS. REFER TO THE HOOD SHEETS FOR PROPER HOOD INFORMATION. THE HVAC CONTRACTOR SHALL INSTALL GREASE RATED EXHAUST DUCT FROM THE HOOD COLLAR TO THE BASE OF THE EXHAUST FANS ON THE ROOF PER NFPA96 AND LOCAL CODES. FLARE GREASE EXHAUST RISER AT THE TOP TO THE OPENING OF THE VENTURI OF FAN. THE HVAC CONTRACTOR SHALL VERIFY LOCATIONS FOR EF-1, EF-2, AND THE HOODS ON SITE WITH DIRECT COORDINATION WITH THE G.C. THE G.C. SHALL SIGN OFF ON THE LOCATION OF FRYER HOOD, SO THAT RISERS CAN BE FIT PROPERLY. TRUSS ENG. GROUP ALLOW SPACING FOR GREASE RISER TO PASS THRU CENTER OF TRUSS BAY AT 2 LOCATIONS, G.C. SHALL COORDINATE STRUCTRUAL FRAMING TO ACCOMODATE PLUM RISERS. G.C. SHALL PROVIDE PERIMETER FRAMING & PENETRATIONS AT ALL ROOF CURBS SIZE & LOCATION WITH HVAC CONTRACTOR. 2. NOT USED 3. SEE NCA PACKAGE SCHEDULE NOTES FURNISHED ITEMS FOR HVAC INSTALLATION. ALL NON -FURNISHED ITEMS NECESSARY TO COMPLETE THE DESIGN INTENT OF THESE DOCUMENTS SHALL BE BY THE HVAC CONTRACTOR. 4. ALL NCA PROVIDED ROOF CURBS SHALL BE FABRICATED FROM 18 GA. G-90 MTL. WITH FULLY WELDED SEAMS, WATER TIGHT AND INTERNALLY INSULATED. FACTORY CURB CONVERSION SHALL NOT BE ACCEPTED. 5. SHIMS SHALL BE PROVIDED BY HVAC CONTRACTOR BETWEEN THE ROOF DECK AND THE CURBS TO COMPENSATE FOR ROOF PITCH ON BUILT UP ROOFS ONLY. OTHER ROOF CONSTRUCTIONS SHALL BE EVALUATED FOR BUILT-IN PITCH ON CURB. 6. ALL FLEX DUCT SHALL BE U.L. LISTED, R-6 BENEATH THERMAL BLDG. ENVELOPE & R-8 WHEN CEILING INSULATION IS USED, FLEX SHALL BE FOIL -BACKED, CLASS 1 AIR DUCT WITH FIRE AND SMOKE RATING [25]-[50]. FLEX DUCT SHALL BEAR A RECTANGULAR OR SQUARE SYMBOL FOR UNLIMITED LENGTH OF RUN OUT OR AS PER LOCAL CODE. 7. ALL METAL DUCT AND AIR DISTRIBUTION DEVICES SHALL BE INSULATED WITH R-6, 2" X .75 DENSITY FOIL -BACKED INSULATION, WITH FIRE AND SMOKE RATING [251-[501. RESTROOM EXHAUST DUCT DOES NOT APPLY TO INSULATION. S. ALL DUCTWORK SHALL BE INDEPENDENTLY HUNG FROM STRUCTURAL MEMBERS, 9. ALL DUCTWORK SHALL BE FABRICATED, INSTALLED, SEALED, AND EXTERNALLY INSULATED PER SMACNA LOW -VELOCITY DUCT MANUAL (LATEST ISSUE). INTERNALLY LINED DUCTWORK IS NOT ALLOWED. 10. UNLESS OTHERWISE NOTED, ALL SUPPLY TAKEOFFS SHALL HAVE A MANUAL VOLUME CONTROL DAMPER. (SEE DAMPER SYMBOLS EXPRESSED ON PLAN. 11. THE HVAC CONTRACTOR SHALL COORDINATE DIFFUSER LOCATIONS ON SITE WITH THE MOST RECENT REFLECTED CEILING PLAN. 12. THE HVAC CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE COVERING A ONE-YEAR PERIOD FOR ALL HVAC EQUIPMENT AND PROVIDE AN ADDITIONAL FOUR-YEAR PERIOD FOR THE COMPRESSORS IN THE RTUS. ALL FANS TO BE U.L. LISTED. 13. UPON COMPLETION OF PROJECT, THE HVAC CONTRACTOR IS TO PROVIDE A CERTIFIED TEST AND BALANCE, AND A WRITTEN REPORT TO NCA CONSULTANTS. ALL CAPACITIES MUST BE SET TO WITHIN +10% OF AMOUNTS INDICATED ON THE FLOOR PLAN AND SCHEDULES. 14. THE HVAC CONTRACTOR IS TO MAKE ALL LOW -VOLTAGE WIRING FINAL CONNECTIONS FOR ALL HVAC EQUIPMENT INCLUDING TEMPERATURE CONTROLS, RTUS, AND SMOKE DETECTORS. GENERAL CONTRACTOR 1. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO RECEIVE, OFFLOAD, AND STORE ALL HVAC MATERIALS WHICH ARRIVE AT THE JOB SITE. ALL MATERIAL MUST BE STORED INSIDE THE BUILDING. FRYER HOOD MUST BE STORED IN THE KITCHEN NEAR PROPOSED LOCATION AWAY FROM THE RISK OF DAMAGE., 2. ACCURATE MEASUREMENTS SHALL BE USED WHEN LOCATING GREASE RATED EXHAUST FAN ROOF PENETRATIONS. G.C. SHALL CONFIRM & SIGN - OFF TO ELEVIATE ANY FUTURE DEVIATIONS OF FINAL HOOD LOCATION. THE G.C. SHALL COORDINATE ANY EFFORT WITH THE STRUCTURAL ENG. GROUP TO ARRANGE TRUSS SPACING TO ALLOW FOR PASSAGE OF GREASE RISER IN THE MIDDLE OF THE BAY BETWEEN TRUSSES. 3. ALL ROOF, CEILING, WALL, AND STRUCTURAL FRAMING REQUIRED FOR UNIT, FAN, DUCT, DIFFUSER, AND ALL OTHER HVAC WORK SHALL BE Q BY THE G.C. COORDINATE ON SITE WITH HVAC CONTRACTOR. GENERAL CONTRACTOR SHALL PROVIDE ANY SCREENING, GUARD RAILS, ETC. LIJ FOR ROOF -MOUNTED HVAC EQUIPMENT PER FBC AND LOCAL CODES. Ct� ROOF FRAMING SIZES ARE BASED OFF OF THE FAN & ROOFTOP UNIT EQUIPMENT SCHEDULERS. IF OTHER EQUIPMENT IS USED, VERIFY ROOF FRAMING REQUIREMENTS WITH SCHEDULES. COORDINATE ON SITE WITH HVAC CONTRACTOR, ROOFING MATERIAL SHALL NOT COVER X THE TOP OF ANY ROOF CURB. O Q ELECTRICAL CONTRACTOR 1. THE ELECTRICAL CONTRACTOR SHALL ROUTE HIGH & LOW VOLTAGE WIRING CONTROL WIRING, LOW VOLTAGE WIRING SHALL BE F- FURNISHED BY THE HVAC CONTRACTOR. LOW & HIGH VOLTAGE WIRING MAY NOT BE IN THE SAME CONDUIT. WIRING MAY NOT ENTER OR EXIT O CURB AT ANY POINT. ALL WIRING SHALL ENTER ROOF TOP UNIT AT OUTER ACCESS. USE WEATHER PROTECTED CONNECTIONS, BOXES & U CONDUIT. DISCONNECTS SHALL BE PROVIDED BY THE E.C. FOR ALL REQUIRED ROOF EQUIPMENT. 2. THE ELECTRICAL CONTRACTOR SHALL USE A MINIMUM OF 4'-6" SEALTITE FLEXIBLE CONDUIT WHEN WIRING KITCHEN HOOD EXHAUST FANS ON ROOF SO THAT FANS MAY BE REMOVED FROM CURBS AND PLACED ON ROOF FOR CLEANING EXHAUST DUCTWORK, 3. FOR EACH UNIT, THE ELECTRICAL CONTRACTOR SHALL PROVIDE ONE SINGLE -GANG RECEPTACLE TEST STATION FOR THE T-STAT, AND ONE DOUBLE -GANG RECEPTACLE TEST STATION FOR THE ANNUNCIATOR, WITH GREEN AND RED LIGHT INDICATORS. THE FIRE AND MECHANICAL INSPECTORS WILL DETERMINE SUITABLE LOCATION FOR TEST STATIONS. ANNUNCIATORS AND TEST STATION WILL BE LOOPED IN THE CIRCUITRY OF THE SMOKE DETECTION DEVICES, WIRING WILL BE INSTALLED BY ELECTRICAL CONTRACTOR. 4. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL INTERLOCKING DEVICES REQUIRED BETWEEN THE HOODED APPLIANCES & HVAC TO COMPLY WITH NFPA-96 WHEN "OPTIONAL NCA PANEL IS NOT FURNISHED". THE USE OF THE "OPTIONAL NCA INTERLOCK PANEL & ON -OFF PANEL" FULLY COMPLIES WITH NFPA-96. ELECTRICAL DISTRIBUTION PLANS & SCHEDULES SHALL BE FORWARDED TO NCA FOR THE PRODUCTION OF THE "OPTIONAL INTERLOCK PANEL SYSTEM" PRIOR TO ROUGH -IN DISCIPLINES OF THE ELECTRICAL CONTRACTOR TO ROUTE HIGH VOLTAGE CIRCUITS THRU ASSIGNED DRY CONTACT TERMINALS IN PANEL & FOR FIELD LOCATION. CONTACTOR PANEL MUST BE IN PLACE PRIOR TO HIGH VOLTAGE ROUGH -IN. PLUMBING CONTRACTOR 1. THE PLUMBING CONTRACTOR SHALL PROVIDE AND INSTALL CONDENSATE DRAINS DOWNSTREAM OF P-TRAPS FOR A/C EQUIPMENT & DISPOSE OF CONDENSATE AT AN APPROVED LOCATION, DO NOT PENETRATE RTU CURB FOR MOUNTING OR OTHER. 2. THE PLUMBING CONTRACTOR SHALL PROVIDE NATURAL OR LP GAS SUPPLY TO ROOF TOP UNITS WHEN USING GAS HEAT, 3. THE PLUMBING CONTRACTOR IS TO COORDINATE PLUMBING VENT STACKS AND WATER HEATER FLUES WITH OUTSIDE AIR INTAKES OF A/C UNITS. 10'-0" MINIMUM CLEARANCE REQUIRED OR PER LOCAL CODE. ATTENTION GENERAL CONTRACTOR: "RE -ENGINEERING" DEVIATIONS FROM THE SHOWN DESIGN AND REQUIRED HVAC EQUIPMENT MUST BE APPROVED IN ADVANCE BY THE PROFESSIONAL ENGINEER. UNAUTHORIZED SUBSTITUTIONS OR ALTERATIONS WILL VOID THE SIGNATURE AND SEAL OF THE PROFESSIONAL ENGINEER AND LEAVE VIOLATORS RESPONSIBLE FOR RESUBMISSION OF SIGNED AND SEALED DRAWINGS. © Copyright 2 0 1 6 - Drawings, specifications, notes, database, computer files, field data, and reports as instruments of service prepared by the Design of Record. As instruments of services, these items remain the property of the Design of Record, who shall retain all statutory and other reserved rights, including the copyright thereto. Any use, reproduction or changes to these documents without written consent of NCA Consultants is a violation of federal copyright laws. m OJ N N M m O m J QJ O L.L.I LL cD cD m N > M r� .N... -N... z 0 L E Ury � _o V y N d LU L.L-I w H LU EE Z Q LU U o J J p] � J w U Mj m K W � d' � M N N OJ W Z W (n O V M I1ZJ W U a4N > N U w v cnO"M 5 F- > V a U o 8 ' Q aNa N C d Q N n d W U Z L L] o Q J m I- J Cn LU 0- LJJ J U rn W �r 2 � H L Q z 0 LU L J / \ = j O � { w Q = F- 0 O IpopRMFI LU O J U) co Lj W � J Q 1 m M a w CO LJL w � 0 W N L � w a 0 Y CL Y J 0 LU 0 LU 0 U) 06 LU F-- 0 z z Q N_ 0. 0 0 LL w U J r- w w = T cn y RELEASE DATE COMMENT RESPONSE 1 03/28/19 z KITCHEN REVISION 06/26/19 3 OWNER REVISION 01/02/20 a 5 s PROJECT NO. 2018-002 ISSUE DATE 12/21 /18 DRAWN ' CHECKED CS CS SHEET NO,y, s M 1.0 3 Y NOTE: F SHALL P 3" VTR Q 1 L- 1-1/2" CD TO GUTTER 2 QCONDENSATE ROOF SUPPORT MAX 10'-0" O.C. (TYP) 10'-0" MIN. SEPAR/ EQUIPMENT STAND SEE DETAIL SHEET A4 IJ ��A--[ iI WALK-INS ICE MACHINE iIII oL3�"VTRA o � QCONDENSING UNITS ---REFRIGERANT LINES THRU ROOF QSEE DETAIL SHEET A4, TYP 3 SMOKE DETECTOR, INSTALL IN RETURN SECTION OF CURB WITH SAMPLING TUBE IN SUPPLY AIRSTREAM (TYPICAL), J 1 NOTE: DO NOT INSTALL SMOKE DETECTOR ON OUTSIDEOFCURB. 1-1/2" CD CO 1„ CD < EF-2 ROOF PLAN - HVAC SCALE 1/4" = 1' -0" WHEN PLOTTED 36" X 24" DUAL POSITION MOTORIZED DAMPER AND WEATHER HOOD. PACKAGE ROOFTOP UNIT WIEGHTS UNIT NUMBER RTU-1 2 & 3 BRAND & TONNAGE CARRIER 8,5-TON UNIT MODEL 50TCD09 CORNER WIEGHT WITH CURB"A" 223# CORNER WIEGHT WITH CURB"B" 171# CORNER WIEGHT WITH CURB "C" 200# CORNER WIEGHT WITH CURB"D" 261# TOTAL WEIGHT 8454 TOTAL WEIGHT WITH CURB 995# 3" VTR A 1" CD 1 CD t ELECTRICAL CONTRACTOR AND PLUMBING CONTRACTOR SHALL PROVIDE CONNECTION TO ROOF TOP UNIT OUTSIDE OF CURB. DO NOT PENETRATE BOTTOM OF RTU UNIT & EXHAUST FAN CURBS. RTU, MUA OR OTHER EQUIPMENT W/FRESH AIR t� Al' CD RTU-3 OUTSIDE AIR HOOD, MAINTAIN 10'-0" MINIMUM FROM ANY EXHAUST OR PLUMBING VENTS (TYPICAL). CONDENSATE DRAIN WITH EXTERNAL 4' DEEP P-TRAP INSTALLED BY HVAC CONTRACTOR. PLUMBING CONTRACTOR SHALL EXTEND DRAII TO ACCEPTABLE LOCATION (TYPICAL). CAL DISCONNECT AND CONTROL WIRING ICE. REFER TO ELECTRICAL PLANS. (TYPICAL). NOTE: FACTORY CURB CONVERSION SHALL NOT BE ACCEPTED. FOR ORDERING INFORMATION REFER TO THE NCA HVAC EQUIPMENT PACKAGE NOTE, SHEET M-1, 10'-0" MIN. SEPARATION Q 1 PLUMBING ( COORDINAT A 10'-0" MIN. S FRESH AIR I OUTSIDE TO ECON f 3" VTR d A ONCA RTU PLENUMIZED CURB DETAIL O HVAC VENTILATION CLEARANCE DIAGRAM NOT TO SCALE NOT TO SCALE LEVEL DUCT SUPPORT SUPPORT DUCTWORK WITH 2" WIDE 26 GAUGE STEEL STRAPS FIRMLY ROOFTOP UNIT ATTACHED TO THE BUILDING STRUCTURE, SPACING SHALL BE MAXIMUM 10-0" FOR RIGID DUCTWORK, AND MAX OF 5'-0" FOR SUPPORT AS PER SECTION 603.10.3(4) OF THE FBC-MECHANICAL. PLENUM sin PLENUM IN CURB IN CURB METAL GLASS TAB START COLLAR IN WITH BEAD - ON S/A USE RIGID LEVELING MATERIAL - MASTIC DAMPER W/LOCKING QUADRANT, TYP. ROOF DECKING - RIGID TEE & REDUCER Wl2" INSUL, WRAP. INSULATE ALL EXPOSED SMACNA GRADE METAL START COLLARS/TEES REDUCERS ETC. WITH 2" FOIL BACKED INSULATION BLANKET WIMIN. FLAME I SMOKE SPREAD 25150 MINIMUM R-6. RUB IN PRESSURE SENSITIVE U.L. RATED 2" WIDE TAPE WITH SPRAY GLUE.. SMOOTH IN WITHOUT WRINKLES. TYP, OF ALL EDGES OF INSULATION TO THERE MATING SURFACES. RADIUS EQUAL TO THE FLEXDUCT DIAMETER OR LARGER-TYP. L 2 ALUMINUM R/A , 2" FOIL BACK INSULATION TAPED TO EDGE OF GRILLE. GRILLE AS SCHEDULED NOTE THIS DETAIL FOR MATERIAL SPEC, AND PROCEDURE. )FLEXDUCT CONNECTION/INSTALL DETAIL NOT TO SCALE I u NYLON STRAP , � AOrvc PLAN \ 5�E SIDE E ���Q REDS gE s SGR 0 I.L65DFEg QPDU�gll4� CIfAWNG 306. ofo N •C •A CONSULTANTS/GROUP 4585 140TH AVE, NORTH, SUITE #1009 CLEARWATER, FLORIDA PHONE'. (877) 530-0078 CALL NCA MARKETING FOR PRICING NCA JOB# 16-1446 TNRR A Sl0 °RI`�F NNOP� Og P8 TO RTgMIN I A a TNR ROOFT°a �c ° CgpFg0E0 \N NIT toUNION N IN „M9 7)1 CONDENSATE P-TRAP & ROOF SUPPORT DETAIL P, TRAP EXHAUST FAN PROVIDED APPLY ISOLATION GASKET BYHUAC CONTRACTOR AND PROPERLY FASTEN BACKDRAFT DAMPER, FURNISHED BY HVAC CONTRACTOR e 18 GA. PREFABRICATED ROOF CURB EXHAUST GRILLE SEE FAN SCHEDULE FOR SIZE. (PROVIDED AT RESTROOMS) EXHAUST GRILLE DETAIL SQ. TO RND. SEE HOOD DETAILS ON M3 SHEET. ROOF PENETRATION & SUPPORT NOT NEEDED ON HOOD-1 FRAMING BY G.C. HVAC CONTRACTOR SHALL MOUNT PROPERLY SMACNA GRADE RND. PIPE. PLENUM DROP W / ENDCAP. SEE SIZE AT KEY SEE SIZE ON PLAN NOTES - THIS SHEET FIELD CUT DROP FOR CONDITIONS APPLY PROPER LAYER OF MASTIC ON ALL SEAMS THE ENTIRE EXHAUST ASSY. \_ HOOD -BY OWNER NOTE: HVAC CONTRACTOR SHALL COORDINATE LOCATION AND SIZE OF ROOF OPENINGS WITH GENERAL CONTRACTOR. PREFABRICATED ROOF CURB FURNISHED AND INSTALLED BY HVAC CONTRACTOR EXHAUST FAN DETAIL - HOOD / RESTROOM =/ NOT TO SCALE ROOFTOP UNIT ISOLATION GASKET -FULL PERIMETER OF CURB HURRICANE WIND SPEED PROTOCAL FOR RISK CATEGORYS BLDG. TYPES III & IV MIAMI-DADE EXHAUST FAN AS PER SCHEDULED MA/C UNIT RAIL/EXHAUST FAN FLANGE 3 SECOND GUST WIND SPEEDS OF 185 MPH AND LESS UP BLAST SHOWN, APPLY ATTACHMENT ECHANICAL FASTENER - FULL PERIMETER APPLY MIN. OF OTHER ATTACHMENT METHODS MAY METHOD NOTED TO ALL FAN CURBS, RTU CURB ONE 5" #14 SCREWS 6" FROM CORNER EDGE AND BE USED IF APPROVED BY LOCAL AUTHORITIES. CURB INSULATION NO MORE THAN 10" ON CENTER THROUGH CURB FLANGE. —.MECHANICAL FASTENER - FULL PERIMETER PERIMETER BLOCKING CANT BUILD UP - BY G.C. F APPLY MIN. OF ONE X-1/2" #14 TEX SCREWS SMACNA GRADE R-6 FLEX DUCT TIED TO STRUCTURE NON-COMBUSTIBEL RIGID LEVELING MATERIAL NO MORE THAN 3" FROM EDGE AND NO MORE BY GO \; SH FLAMEISMOKE SPREAD 25150 IMING TO LEVEL CURB TO ADJUST FOR ROOF PITCH THAN 6" ON CENTER THROUGH CURB FLANGE ROOF DECKING ON ALL SIDES 12 GA. UNISTRUT OR OTHER j- MATERIAL OF EQUAL - -I F STRUCTURAL INTEGRITY STRADDLING UNDERSIDE OF THE APPLY MASTIC TO COLLAR AND SLIDE FLEX SECURE A/C CURB TO STRUT WITH MIN. 5116" ALL THD. OR TOP CHORD OF TRUSS PROPER LENGTH STOVE BOLT WITH FENDER WASHERS SECURE FAN CURB THRU 12 GA. FENDER WASHER, DECK, RIGID OVER BEAD WHILE STILL WET, PANDUIT STRAP AND LOCKING HARDWARE, THRU ROOF DECK AT 12" O.C.HURRICANE WIND SPEED PROTOCAL FOR: IN PLACE, INSIDE OF BEAD. TYPICAL OF ALL FLEX RISK CATEGORYS BLDG, TYPES III & IV MIAMI-DADE LEVELING MATERIAL AND THRU PRE -DRILLED 2X4 LG. P,T, WITH TO METAL CONNECTIONS, AND A MIN. OF (3) AT LONG SIDE OF CURB UNDER 72" & A 3 SECOND GUST WIND SPEEDS OF 185 MPH AND LESS PROPER LENGTH 5/16" DIA. LAG BOLTS. USE 1 CITY. OF (4)OVER 72". - OTHER ATTACHMENT METHODS MAY PER SIDE FOR FANS LESS THAN 24" LENGTH & 2 PER SIDE FOR LAY -IN CEILING BE USED IF APPROVED BY LOCAL AUTHORITIES, CURBS OVER 24" FOR EACH SIDE OF FAN CURB. L ALUMINUM S/A DIFFUSER AS WOOD TRUSS PRE -DRILL HOLE TO 1/4 DIA SCHEDULED WOOD TRUSS OFAN CURB HURRICANE MOUNTING DETAIL O ROOF EQUIP. CURB MOUNTING DETAIL Nor TO SCALE NOT TO SCALE ©Copyright 2016 Drawings, specifications, notes, database, computer files, field data, and reports as instruments of service prepared by the Design of Record. As instruments of services, these items remain the property of the Design of Record, who shall retain all statutory and other reserved rights, including the copyright thereto. Any use, reproduction or changes to these documents without written consent of The NCA Group is a violation of the Federal Copyright Laws. 0 w U 0 O elf - w Of w m O H- O z Lu cr a w x uP U z w z U) w w x H 0 z Q Tn z w U O w w U) w x H- O H 0 H- x Of W w 0- 0 IL W w _ O J J a Z Q _ O a O U U) H U w Lu w W w Of J to W w a X w O O V W J N V N m M OJ OJ � J OMJ pNj /W/ t..t� / Ii = , N N = v z a¢ o f— M E U 0Y N a m f— LU =z Q W U J J _o m � J W U � � Y > m 0 M L Z W O a J N Z a o W o v N > N U � M � d E N VJ [l U- Z W o Q J m J Cn LU 0- W J Q W a = U w ~ N rn o CD ti S Q 0 x F O w = L w 04 O CO popeYes w O J co w -J z W F-- W U N � w Y 0- J 9 0 J_ Q LU 0 06 Q J OL LL 0 0�/ W U H H Q w w S T In y 2020 STW.C4,, .......,..q , ,,\\ ENS*F :16, ,i a No 44843 j� :� • STA OFFt I U J RELEASE JAIL COMMENT RESPONSE 03/28/19 2 KITCHEN REVISION 06/26/19 3 OWNER REVISION 01/02/20 4 5 6 PROJECT NO. 2018-002 ISSUE DATE 12/21 /18 DRAWN CHECKED CS CS SHEET NO. q•, .T M2.0 4"GCO PLUMBING FIXTURE SUMMARY _ FIXTURE FQ TY. DRAIN COLD WATER HOT WATER D.F.U. SAN. WASTE GREASE WASTE TOTAL D.F.U. F.U. CW TOTAL CW F.U. HW TOTAL HW WATER CLOSET (P1,P2)) 2 4 8 8 2 4 LAVATORY (P5) 2 1 2 2 2 4 2 4 HAND SINK (N10) 3 2 6 6 2 6 2 6 PREP SINK (A35L) ** 1 3 3 3 3 3-COMP SINK (040) ** 1 3 3 3 3 HOSE BIBB (WHD) 2 5 10 WATER FILTER 2 1 2 FLOOR DRAIN (FD-A) 7 2 14 14 FLOOR DRAIN (FD-B) 3 2 6 6 FLOOR DRAIN (FD-C) 1 2 2 2 HUB DRAIN (HD) 4 2 8 8 FLOOR SINK (FS-A,FS-B) 8 5 40 40 MOP SINK (MS-1) 1 2 2 2 3 3 3 3 TOTAL 16 72 88 35.00 1 ).0 BASED ON 2014 FBC-PLUMBING 35.0 FU = 25.0 GPM USE 1 1/2" COLD WATER SERVICE 19.0 FU = 13.5 GPM USE 1" HOT WATER SERVICE GREASE WASTE = 72 WFU USE 4" SANITARY (GREASE) TOTAL SANITARY = 88 WFU USE 4" SANITARY ** FIXTURE HAS INDIRECT WASTE TO FLOOR SINK. .� R 3• - 3"VTR Fn- 1 LEI ` 'LA I ,1 co FS-1- rl ,I i PLAN NOTES ❑ 1. 4" SANITARY WASTE PIPING. SEE CIVIL ENGINEERING DRAWINGS FOR CONTINUATION. COORDINATE EXACT INVERT ELEVATION WITH SITE CONDITIONS. 2. 1-1/4" CONDENSATE PIPING BRACED TO WALK-IN WALLS. SPILL W/INDIRECT CONNECTION INTO HUB DRAIN. PROVIDE ELECTRICAL HEAT TRACE TAPE TO PREVENT CONDENSATE LINE FROM FREEZING. 3. CO2 AND SODA LINES WITH FILTERED WATER RUN OVERHEAD RUN OVERHEAD IN CEILING SPACE. 4. DROP PIPING DOWN IN EXTERIOR WALL. STUB OUT OF WALL @ 96" AFF INTO GREASE TANK, SEE GENERAL NOTE 5, PROVIDE HEAT TRACE TAPE ON EXPOSED GREASE LINE FROM BLDG. TO TANK, SEE GENERAL NOTE (SHEET: PO) 8, PROVIDE 1-1/2" INDIRECT WASTE FROM 1 COMP SINK TO FLOOR SINK. 7. ROUTE DRAINAGE TO FLOOR SINK UNDER ITEM K-32. g. PROVIDE DRAIN LINE FROM REFRIG. BATTER STATION TO HUB DRAIN. 9. GREASE DISPOSAL LINE MOUNTED FLUSH AGAINST WALL 3'-0"A.F.F. (SEE DTL 7/P4). G.C. TO PROVIDE STAINLESS STEEL COVER TO CEILING -SEE GENERAL NOTE #18/P0. 10. PROVIDE 2" INDIRECT WASTE FROM 3 COMP SINK TO FLOOR SINK. 11, 3" VENT UP IN WALL FURRING. 12. OFFSET VENT LINES ABOVE CEILING, AND ROUTE TO VTR'S AT LOCATIONS SHOWN, TO AVOID O.A. INTAKE FOR RTU. 13. PROVIDE (2) 3" PVC CONDUITS INSIDE WALL FOR BEVERAGE LINES. TERMINATE 18" A.F.F. WITH 450 SWEEP, TOP AND BOTTOM 14. OFFSET CONDENSATE DRAINAGE TO AVOID ELECTRICAL CONDUIT FOR WALL MOUNTED LIGHTING > N :3 N W CS��� G E > � � z a o c m W W " f- W = Z U (7 � Z Q W J � J [� J U w U � � W �p N M O) W W� d� E_ .'t: O ' = t N (n LL LL 0 w U 0 O o_ w D: w m O H O z W Q W F- EQUIPMENT SCHEDULE W QTY. TAG DESCRIPTION z 1 A11.6 Fryer Battery, 6-20", Electric CD 1 A351 Sink, 1 Compartment, Left Hand Drain Board, 52" o 1 A47.4 Ice Batter/Sifter Table, 4 Pans, 100" w 1 A92 Grease Collection System � 1 D30 Packing Station w Cup Dispenser &Dipper Well a 1 D40 Sink, 3 Compartment, 94" Long, 18" DB, R & L U) 1 D81 Chubb Warmer, Elec. Rethermalizer W 1 E10.1 Walk -In Cooler � 1 E10.2 Walk -In Freezer o 1 H10.3PD Production Counter, Dual Line, 52 1 4" x 134" Prince -Castle n 1 K11 Ice Cuber w/ Remote Condenser F 1 K16 Ice Bin, 660 Ibs 0 1 K20 Water Filter, Equipment U) 1 1 K31 K32 Soda Dispenser, 8 Heads, Drop -In, Fast Flow Valves � Soda Dis enser, 8 Heads, Counter w Ice Bin, Adapter Plate � 1 K40 CO2 Tank, Bulk w 1 K42 _ Bag-N-Box Rack /w 2 Carbonators on Shelves o 1 K71 Brewer, Tea &Coffee 3 K72 Tea Dispenser, Urn, Solid Lid = 3 N10 Hand Sink, w/ Hand Free Lever O 1 N20 Mop Sink a 1 N31 Water Heater z PLUMBING PLAN � WAFT[= VEIv1T f✓'L-AI'vI 1 /4"=l'-O" -_ SEAL 11111111 Z W o J m cn J a w J = U N rn Q W w 1= o cro- p p = o w 3 �w �o N popevesry MARK I FIXTURE P-1 WATER CLOSET (HANDICAP) P 2 WATER CLOSET (HANDICAP) z w O J Q CJ) U) W J p I Ili gW C-0 w U i 0... N � w 3O� � a m J � o PLUMBING FIXTURE SCHEDULE Cn ,,••��a?.1o�,�. CONN. MANUFAC. CONN. MANUFAC. _ -c~i� ����Q�O�.�GENSF••,• �4 & MODEL DESCRIPTION MARK FIXTURE W CW HW 8, MODEL DESCRIPTION > 4 ';. ; W CW HW _ ►Jp 44843 4" I 1/2" C9IIIIIIIIIIIIIIf/PaY Lu VITREOUS CHINA, ENLOGATED BOWL 1.6 PLASTIC ADJUSTABLE CLEANOUT ASSEMBLY WITH w 8TATE F : w AM. STD. GALLON FLUSH WIWHITE PLASTIC OPEN FRONT FLOOR 2487.016 - - ODDITIES } �� (t�` SEAT, CHROME PLATED BRASS SUPPLY &STOP, FCO CLEANOUT 4" BRONZE COVER AND METAL RING � A,P: ,•c � AND PVC CLOSET FLANGE WITH WAX SEAL. tmi3 fds�S fG'tN�,�`` � R6$AftNE%ShNE SAME AS "P-1" EXCEPT WITH 4142.800 PLASTIC X FLORIDA PE. #44643 AM. STD. TANK WITH RIGHT-HAND TRIP LEVER. GCO GRADE 4" - - ODDITIES PROVIDE WITH METAL RING w 2487.016 CLEANOUT pG1-622R N RELEASE DA1 ' I COMMENT RESPONSE 031281 WIt R WALL HUNG WITH 4" FAUCET HOLES, 2 KITCHEN REVISION 06/26/ © AM STD. 605E ELEC. PROX. LAV. FAUCET PLASTIC W/ S/S COVER PLATE P-5 LAVATORY 1-1/4" 1!2" 1/2" AM. STD. LONG LIFE BATTERY - 6053.205 WALL SEE SSA-600 3 OWNER REVISION 011021 (HANDICAP) 9141.011 WCO CLEANOUT RISER ODDITIES G.C. TO PROVIDE/INSTALL COMPATIBLE CONCEALED PIP SERIES 4 BRACKET CARRIER 5 85 GALLONS STORAGE TYPE, 208V / 3PHASE, 18 KW, 6 FD-A FLOOR PLASTIC HEAVY DUTY ADJUSTABLE DRAIN WITH 5" ELECTRIC „ RHEEM 50 AMPS, 74 GPH 100°F RISE, 6 HEATING FD-C DRAIN 3„ ODDITIES NICKEL STRAINER W/ROUND TOP EWH-1 WATER 1 1 E85-18-G ELEMENTS ( ) PHD 822R FD-C: SAME AS FD-A, 4" HEATER PROJECT NO. 2018-002 FLOOR PLASTIC FIAT MOLDED STONE 36X24, FAUCET FD-B 3" ODDITIES SAME AS FD-A, EXCEPT W/1/2" TRAP MS 1 MOP SINK 3" 1/2" 1/2" MSB 3624 W/VACUUM BREAKERS, 830-AA, BASE & DRAIN PRIMER CONNECTION W/FAUCET PHD 822R BRACKET 832-AA. ISSUE DATE 12/21/18 FLOOR PLASTIC 3" FLOOR SINK WITH DOME TOP OPTIONAL FIAT MOLDED STONE 24X24, FAUCET FS-A SINK 3" ODDITIES STRAINER, AND 3/4 GRATE MS-2 MOP SINK T. 1/2" 1/2" MSB 2424 W/VACUUM BREAKERS, 830-AA, BASE & PFS-300-T W/FAUCET BRACKET 832-AA. DRAWN CHECKI CSI - ZURN 3" FLOOR SINK, 12"X12" A.R.E SANI-FLOR CS , FLOOR Z-1900-2-33 RECEPTOR ANTI SPLASH STRAINER - WALL _. WAODFORD ANTI -SIPHON, AUTO DRAINING, W/ VACUUM BREAKER, NOTES: FS-B SINK 12"X12"X6" AUIV RCOIO I. FORCETIN CINAIVICL vvRu-1 HYDRANT A/4 FREEZLCOO VVALL RT URAIN I, J/•1 IVIAL= nVOC 1 nMC U 1. ALL VITREOUS CHINA FIXTURES SHALL A.R:� INTERIOR AND S0. TOP MODEL 65 NOZZLE BE WHITE. 2. INSULATE ALL WATER AND WASTE PIPING UNDER LAVATORIES WITH HANDY -SHIELD JACKET BY PLUMBEREX: (619)633-1772. Lu HUB WALL JOSAM ANTI -SIPHON, AUTO DRAINING, W/ VACUUM BR HD-1 pR,gIN 3" - - - SEE DETAIL WHD-2 HYDRANT - 3l4" 314" 71650 FREEZLESS WALL HYDRANT, 3/4" MALE HOSE NOZZLE, HOT AND COLD WATER SHEET N0. P 1' WALL HUNG WITH 4" FAUCET HOLES, 2 KITCHEN REVISION 06/26/ © AM STD. 605E ELEC. PROX. LAV. FAUCET PLASTIC W/ S/S COVER PLATE P-5 LAVATORY 1-1/4" 1!2" 1/2" AM. STD. LONG LIFE BATTERY - 6053.205 WALL SEE SSA-600 3 OWNER REVISION 011021 (HANDICAP) 9141.011 WCO CLEANOUT RISER ODDITIES G.C. TO PROVIDE/INSTALL COMPATIBLE CONCEALED PIP SERIES 4 BRACKET CARRIER 5 85 GALLONS STORAGE TYPE, 208V / 3PHASE, 18 KW, 6 FD-A FLOOR PLASTIC HEAVY DUTY ADJUSTABLE DRAIN WITH 5" ELECTRIC „ RHEEM 50 AMPS, 74 GPH 100°F RISE, 6 HEATING FD-C DRAIN 3„ ODDITIES NICKEL STRAINER W/ROUND TOP EWH-1 WATER 1 1 E85-18-G ELEMENTS ( ) PHD 822R FD-C: SAME AS FD-A, 4" HEATER PROJECT NO. 2018-002 FLOOR PLASTIC FIAT MOLDED STONE 36X24, FAUCET FD-B 3" ODDITIES SAME AS FD-A, EXCEPT W/1/2" TRAP MS 1 MOP SINK 3" 1/2" 1/2" MSB 3624 W/VACUUM BREAKERS, 830-AA, BASE & DRAIN PRIMER CONNECTION W/FAUCET PHD 822R BRACKET 832-AA. ISSUE DATE 12/21/18 FLOOR PLASTIC 3" FLOOR SINK WITH DOME TOP OPTIONAL FIAT MOLDED STONE 24X24, FAUCET FS-A SINK 3" ODDITIES STRAINER, AND 3/4 GRATE MS-2 MOP SINK T. 1/2" 1/2" MSB 2424 W/VACUUM BREAKERS, 830-AA, BASE & PFS-300-T W/FAUCET BRACKET 832-AA. DRAWN CHECKI CSI - ZURN 3" FLOOR SINK, 12"X12" A.R.E SANI-FLOR CS , FLOOR Z-1900-2-33 RECEPTOR ANTI SPLASH STRAINER - WALL _. WAODFORD ANTI -SIPHON, AUTO DRAINING, W/ VACUUM BREAKER, NOTES: FS-B SINK 12"X12"X6" AUIV RCOIO I. FORCETIN CINAIVICL vvRu-1 HYDRANT A/4 FREEZLCOO VVALL RT URAIN I, J/•1 IVIAL= nVOC 1 nMC U 1. ALL VITREOUS CHINA FIXTURES SHALL A.R:� INTERIOR AND S0. TOP MODEL 65 NOZZLE BE WHITE. 2. INSULATE ALL WATER AND WASTE PIPING UNDER LAVATORIES WITH HANDY -SHIELD JACKET BY PLUMBEREX: (619)633-1772. Lu HUB WALL JOSAM ANTI -SIPHON, AUTO DRAINING, W/ VACUUM BR HD-1 pR,gIN 3" - - - SEE DETAIL WHD-2 HYDRANT - 3l4" 314" 71650 FREEZLESS WALL HYDRANT, 3/4" MALE HOSE NOZZLE, HOT AND COLD WATER SHEET N0. P 1' e B RISER DIAGRAMS P3 N TS 2 , / I � 6 3- / Fco /� / / / / / D40,F /N N 10 I y C F i F / �P����A y ,<g% �N10 v To EllPy // / lY//� %� / ' 081 -J- WASTE AND VENT RISER SEE SHEET P1 FOR PLAN NOTES T i \ 11 -c g 42 F'F 41- 0 K20 `• //\ / �i`�� ��/�' /12/ �2`F✓' Icy ,`���/� OBI"L' �✓ '�'/ `, �2 'SIB 1 I q� 35L� N10 85` AFT ✓° N 10�I I ti F PF� D-30 DOMESTIC WATER RISER SEE SHEET P2 ❑ FOR PLAN NOTES 24 PF 6 w U 0 O LU w w co O z w Q W x w U z w z cD U) w w F- z Q O z z w v O 0 w U) w 2 H O F U) H _ C7 01 w 0- 0 a w O J J Q z Q F- x a O C) U) H U) w w Lu w J O cn w a X w U) J m O) N N M OJ O W (Up J QMj � y N L !n C6 G 6 M M ¢ZD d z o 0.m "' E U of_� (V d U W W m I-- W Z Qw U J J _o p] � J w z C� in F- O Z -o J N l6LLOO w w U U o 4o g m � Ta > N (n O Z o o M u 0 U n N d E z N n .� D cN.� R N In LL LL U W Q J 00 W a_ W Q J Q U w N c) o w �Q Z p �� O w = w W J > 04 :D O a W 0. v NSF;9SF OF ",;*VNAL t", ROBERT WAYNE CASE FLORIDA PE. #44643 Mr LCAJC UAIC COMMENT RESPONSE 03/28/19 2 KITCHEN REVISION 06/26/19 3 OWNER REVISION 01/02/20 a s 6 PROJECT NO. 2018-002 ISSUE DATE 12/21/18 DRAWN CHECKED cs cs J SHEET NO. _ P3 e _3 B-SCE® 0 GPM Grease Interceptor for Indoor / Outdoor Use �� (32 cm) IU%2 (27 cn) 37" 49%2" I I (94 cm) (126 cm) 39" (99 cm) 94% �46" '_(239 cm) (717 cm) Grease Interceptor Calculations FPC 1003.4 "Size in accordance with PDI-G101" PDI-G101, Tabfe 8.3.1 Step One - HOW Rate / Fixture Capacity 3-Comp Sink 18' X 24" X 18" X 3 romps = 23,328 w in 1-Comp Prep Sink 18" X 24" X 18" = 7,776 cu in Mop Sink 24" X 24"X 1D" = 5,760 aril Total = 36,864 Cu in J 231 X 0.75 = 120 / 2 mIn = 60 GPM Step Two - Grease Production 600 meals/day 0.035 Ibs/meal - High Grease (no flatware) 90 days per pump -out cycle 90-Day Grease Production = GOO meals/dayX 0.035 lbs/rrreal X 90 days = 1,890 111 DESCRIPTION: F�tly,:jtlr/Ic,,IreO`I,eeselnC�IL:K�toa` MODEL NUMBER: FlowRates/Grease Capacities: 100 GPM /3,048 111 GB. Liquid Capacity: 510c)HI 15 OPTIONAL HYDROMECHANICAL GREASE TRAP P4 NTS „A„ TOP VIEW 24" HEAVY DUTY CAST—: IRON FRAME & COVER WITH "GASTIGHT" GASKET — STANDARD. 4" INLET & OUTLET PIPE AND FITTINGS STANDARD RISERS AS REQD. Q INVERT < INLET SECTION G.T. SIZE DIM. "A" DIM. "B" 1200 GALLON III 5'_ GREASE LOAD CALCULATION S = TOTAL SEATS GS = GALLONS OF WASTE WATER PER SEATS HR — HOURS OF OPERATION LF = LOADING FACTOR M = DRIVE THRU MEALS PER DAY GM = GALLONS PER MEAL (S) x (GS) x (LF) - (25%) = EFFECTIVE SEATING CAPACITY IN GALLONS (46) x (10) x (12/12) x (1) x (0.75) = 345 GALLONS PLUS (M) X (GM) X (LF) = EFFECTIVE TAKE OUT MEAL IN GALLONS (150) X (5) X (1.0) = 750 GALLONS TOTAL = (345) + (750) = 1095 GALLONS: USE 1250 GALLONS 13 CREASE TRAP DETAIL P4 FITS BALL VALVE I 101 TEMPERED WATER TO PLUMBING FIXTURES THERMOMETER 140' HW SUPPLY — — — — — ------ PROVIDE 2FT. MIN, HEAT �09 TRAP IF NOT PROVIDED AT HEATER OR IF VALVE IS 2'MIN. LOCATED AWAY FROM HEATER. COLD WATER SUPPLY ICJ CHECK VALVE DETAIL NOTES 1. 2. SEE PLANS FOR HW SIZES FROM WATER HEATER SYSTEM TO MIXING VALVE ASSEMBLY. REDUCE AT ASSEMBLY AS REQUIRED. 3. INSTALL PER MANUFACTURERS PUBLISHED RECOMMENDATIONS. C14 THERMOSTATIC MIXING VALVE P4 NTS SECURE PIPING TO WATER HAMMER ARRESTOR - PRESSURE REDUCING JOSAM N0. 75003 VALVE - WATTS OR EOUIVALENT— NO. U5B SET 80 PSI MAXI aO C' L I z FINISHED FI.00P. o COLD WATER SERVICE TYPE "L" COPPER, SOFT TEMPER FLO 1" HW TO BUILDING P4 /NTS THERMOMETER / T & P RELIEF VALVE — RUN RELIEF VALVE PIPING TO FLOOR DRAIN EWH-1 DRAIN VALVE WITH HOSE THREADS WATER HEATER — s ELECTRIC WATER HEATER DETAIL P4 NTS ACCESS DOOR FOR MAIN SHUT-OFF /,,HALLMANN SALES, LLC #DSC-214M 12x12 ---MAIN SHUT-OFF BALL VALVE ELECTRICAL GROUNDING CONNECTION —PER NEC SECTION 250 GRND PIPE SLEEVE TO BE ONE PIPE SIZE LARGER THAN PIPE. SEAL OK'LY WITH APPROVED CAULKING CW PIPING TO ABOVE CEILING \—SLEEVE TO BE PVC SCH. 40 AND SHALL EXTEND 1/2" ABOVE SLAB (TYPICAL). 10 COLD WATER SERVICE ENTRANCE FW TO DRINK SYSTEM 3/4" CW INLET AT O T( 8'-4" AFF Ol I�I'rI I I FW 10 ICE n r i i MAKER AND MF COFFEE MAKER PALL MC MC MC MC VALVE (TYP) UNION (TYP) 12 WATER FILTER DETAIL P4 FITS 3/4" HWR 1" CW SUPPLY RECIRCULATING PUMP TO BE CONTROLLED BY AQUASTAT BALL VALVE TO BALANCE SYSTEM. MUST BE DOWNSTREAM OF PUMP EXPANSION TANK WATTS DET-5 NOT USED NITS BAD VA! VE BALL VALVE PING W/ HEAT APE SUPPORT X © 7 CREASE RECOVERY BONNE(7TION P4 NTS cc -- R S PVC WYE (WYE WITH REDUCING BRANCH IF MAIN IS OVER SINK STRAII WITH WATEF MEMBI MEMBI FLASH FLANG m DISCHARGE SCHEDULE PVC W/RE (SIZE AS I ON DRAW[ USTABLE N HEAD FLOOR 0DY _AULI( N V N m OJ N W M 6> OJ (Up J QMj pMj LLJ LI. f r1 E V ¢�� mZD _Z o c M E N a � W W LL I— LLJ = z Q LIJ J n J p] � J W U M can w W Elf o0 _ N cNi rn (D w w (¢ a aoN Uo ..4r =- 5 N c, � W F W > o N N K N c Q N azs , 8 I ���==M N�naLL 4 FLOOR DRAIN P4 NTS o U a HUB DRAIN P4 NTS FLUSH COVER FIN. FLOOR -� C CLEANOUT PLUG PVC BEND AND BODY, SEE SPEC FULL SIZE, 4" MAX. PVC WYE (WYE WITH REDUCING BRANCH IF MAIN IS OVER 4=L�-, PLUG IF END OF LINE FLOW / _v s FLOOR SINK P4 � NTS 3 COMPARTMENT SIN 2" DRAIN LINE_11 -'_ 2" TO INDIRECT CONNECTION Z F.S. 5 3 COMPARTMENT SINK P4 NTS O of a W W C0 O F- O Z W CC Q w uP AP = 2 OR 2" Z W x Z O —4" (UNLESS W OTHERWISE NOTED 0 PLANS) /,_f)F e FLOOR = F-- p Z U z W o Q J m I— co W a W _j Q LLI x U W = N rn CO r 11 � � L Q z 0 z O j O W 2 L Lu O Q . U LLJ FLOOR SLAB 0-� W U W O H H- 2 , CD Z Cl� LLI W O 0- Oof J Cl- Q 0� ' U) u0 W O `Wy W / Z W _1i W W O N Y R ADJUSTING. COLLAR Of 0- SEA[ PVC RISER O , U PVC BEND H P FULL SIZE, 4" MAX. U) W > I Cc Lu PLUG IF END OF LINE W I; of FLOW U W w of 2 FLOOR CLEAN —OUT w P4 U NTS .j FLUSH HEAVY DUTY CAST IRON TRACTOR COVER 18"X18"X6" THICK FIN. GRADE CONCRETE COLLAR f '. �1i hIIF CLEANOUT PLUG >1 ADJUSTING COLLAR AND BODY, SEE SPE PVC RISER VCl/8 BEND PVC WYE FULL SIZE, 4" MAX. (WYE WITH REDUCING BRANCH IF MAIN IS OVER ' PLUG IF END OF LINE FLOW X ---V GRADE CLEAN —OUT P4 N TS #'k I'(CLCHJC UAIE COMMENT RESPONSE 03/28/19 2 KITCHEN REVISION 06/26/19 a OWNER REVISION 01/02/20 4 5 6 PROJECT NO. 2018-002 ISSUE DATE 12/21 /18 DRAWN CHECKED r CS CS SHEET NO. P4 T /A 24" SERVICE SIGN & 4 " GFI ' PUSH BUTTON VPJ ' FOR IRRIGATION A31 CONTROLLER, 16 B (VERIFYEXACTLOCATION) 78 A-1 A-7 A-22 B-6 C A-10 17 "DPr 96"„B" A„ "C" 13 E.C. SHAPROVIDE C 3/4' C.STUBBED POWER CO VAP-BOVE CEILING FOR METER & MAIN - WP ANSUL SYSTEM SEE RISER 4 A-36. T DIAGRAM SHT E3 A-38,40,4 102 J A-22 16 WP 17 .' H TR E.C. SHALL WIRE & WP/GFI J CONNECTG.C, FOR HEAT TRACING PROVIDED REMOTE IN THE COOLER 3 ANSUL PULL STATION A-t 18 CU' C-19 11 CU-F CU A72" 3❑ WP ,e185szsoY' MAI WP J-BOX & DISC SW --' VW T E10 ® NOTE: CONTRACTOR TO PROVIDE MIN. 70 A 4' LONG CORD AND PLUG FOR ELEC. FRYERS (1 PER EACH). RECEPTACLE SHALL BE RECESSED POWERTITE 100AMP ADJA1034 200 AT 18 A.F.F. C-28 DP-13,15,17 DP-38,40,42 DP-37,39,41 DP-14,16,18 DP-8,10,12 DP-2,4,6 C-5 A A-35,37 (TIE, 18" 23 23 23 23 23 23 96 1'-10 V-91/2" 1'-10" 1'-9" ALL KITCHEN AREA RECEPTACLES ARE TO BE LOCATED IN WALLS/BULKHEADS. NO KITCHEN AREA RECEPTACLES SHALL BE LOCATED IN THE CEILING ALL 15A AND 20A RECEPTACLES IN KITCHEN SHALL BE GFCI 0 PROTECTED -8 -0 I uH•D• H.D. J A-20 INTERLOCK W/ -40" B-11,13,15 LIGHT CIRCUIT B-5 54" 18" J A-15 16 C-34 _ 14 8-19 12 JIG H10.3P D92 D94 D92 J40 I B-3 D93 NI 51 100" oI IG �I QUAD Pzo gI RECPT. PO 24" 27 (nI B-3 8-38 P3o 10n II WI IG M30 zI - - {7 31J WP/ B-1 16 I�� DP-26,28f0 " I RTU-218 g-36 A �AI B-29❑ IG A-6 16 4 WIRE TO GREASE 5 J 3 CONTAINER WP. GFI A-17 A-26,28A-39,41 B-19 IG -- C_7 K72 A-25,27 C-11,13 C-21,23 - 13 17 © 48" 21 A-29,31 18" HTR EVAP-F A-23 78" A-9 D81 12" J D70 80" D20 54 ]6 D90 J FOR HEAT TRACING IN THE FREEZER. NEMA 6-30R NEMA 6-30R D3o NEMA 5-30R 21 ndn RUN 2 - 2" CONDUITS FROM TELEPHONE EQUIPMENT BOARD TO A LOCATION COORDINATED WITH LOCAL TELEPHONE COMPANY, OWNER REQUIREMENT SERVICE CONDUITS SHALL BE SIZED FOR 25 PAIR (MINIMUM). TELEPHONE SERVICE CABLE, CONDUITS SHALL BE INSTALLED WITH PULLWIRE, CONDUITS RISE FROM U.G. INSIDE EXTERIOR WALL AND TURN -OUT WITH 90 DEG ELLS INSIDE BLDG. AT TERM. BD. SEE ARCHITECTURAL ELEVATIONS. OWNER REQUIRED SEPERATE TELEPHONE SERVICE LINES TO BUILDING: (1) LINE FOR VOICE (1) LINE FOR SECURITY (1) LINE FOR CREDIT CARD (1) LINE FOR CASH REGISTER (1) LINE FOR COMPUTER LINES CABLE/S DATA TEL DUAUDOUBLE [IV ; SINGLE 13 .0 22 24 24 EF-4C-9 RS 40" WP/GFI JNPA-5 C SD 24" 2L�8 " UZZER CO K42 (HQ24 8. 24" As A-s I 7 8-9 A-19 RTU-1 El 8 18 A-1,3 _C-1 - A-4 9 [Io I EF-1 _A-1 A 3EF-2 20 J 8' x✓/ ✓ `\ ® V I J 6 04" I B60 24" _oo J 865 44 54" 44 84" 22 25 B10 18 E OFFICE C-18 C-12,14, A-16: A-6 C-10 A-8 16 DP-1,3,5 DP-7,9,11 A-11 B-19 12 IG EXTEND CONDUIT 3/4" CONDUIT TO TTB FROM N N o 0 0 TO TTB IN OFFICE BY TENANT'S^ EACH TELEPHONE OUTLET m m m m m J 8" CONTRACTOR TELEPHONE DINING POS N SERVICE CONDUIT TO SPACE BY TTB DRIVE THRU 4" LANDLORD TELEPHONE IG o EQUIP. BD. OFFICE - 72„ NOTES: o N 1. G.C. IS RESPONSIBLE TO PULL THE CORRECT WIRE TO BRING THE PHONE m 4" LINE FROM THE DEMARK. N N 1 w ro 2. INSTALL THE APPROPRIATE JACK TO SUPPORT THE PHONE AND DSL ROUTER. C0 m 0i of 0" IG IG o m 18„ NOTE: REFER TO OFFICE ELEVATION ON SHEETS Al2 & A16. CONDUIT BUSHING WITH TERMINATION AT 6"ABOVE FINISHED CEILING. 1" OR 3/4 CONDUIT WITH PULL STRING AS NOTED. RECESSED SINGLE GANG ELECTRICAL BOX. FINISHED FLOOR 2 ) TYP COMM. STUB UP DETAIL E2 J NTS REFR TO SITE PLAN FOR EXACT LOCATION 18" ' C CEILING MOUNTED B-23 RECEPTACLE & DATA FOR TV �� - , DP-32,34,36 � >/ 1 16 B- I I WP/GFI 6❑ 4-18 I I F JNP_ SD J -- 7 18 I RTU-3 ElI � I I I > o v c N V C m M C 16 BRANCH CIRCUIT(S) CONTINUED TO ADDITIONAL OUTLETS, HOMERUN SHOWN atOi LL u FOR CLARITY ONLY. Lu �0 ? N c POWER PLAN KEY NOTES 17 COUTLET AND AMERA TO BEONNETIOED NFORSECURIB �-- z was f BELOW CEILING GRID. VERIFY EXACT U i REFER TO FOOD SERVICE DRAWING K1 FOR LOCATIONS AND TYPE CONNECTIONS FOR u TAG LOCATIONS NOT SHOWN THIS SHEET. INDOOR AND OUTDOOR CAMERAS WITH G.C.. w LLI uj REFER TO HVAC DRG. M1 FOR EXACT LOCATIONS 1$ ROUTE ALL CONDUIT ROOF PENETRATIONS = Z Lij lFOR MECHANICAL HVAC EQUIPMENT. THRU (WITH -IN) ROOF CURBS FOR THE U EQUIPMENT. REFR TO MECH. PLANS FOR z CURB DETAILS. (TYPICAL) ry F 3P30A NEMA 3R FUSED DISC. ON WALK-IN COND, Q W UNIT LOCATED ON ROOF. FUSE PER EQUIPMENT 19 PROVIDE 1" CONDUIT TO 6" ABOVE NAMEPLATE. LIQUID TIGHT FLEX CONNECTION. CEILING. MAKE FINAL POWER CONNECTION TO WALK-IN zHOOD ANSUL FIRE SUPPRESION COOLER EVAPORATOR, PROVIDE MOTOR SYSTEM. vi � SWITCH IN CAST BOX. w U MAKE FINAL POWER CONNECTION 21 MAKE FINAL CONNECTION TO w > ro b WALKw o v a FREEZER FREEZER EVAP., DEFROSTER, ER, HEATAT EQUIPMENT w �M z TAPE & DOOR HEATER. © CD �- z ❑ 22 OFFICE CABINET FAN WITH WALL SWITCH. z z U (2 o w w d PROVIDE LOCAL 3P60A NEMA 3R NON -FUSED �- o 6 5; DISC SW. ON A/C RTU'S LOCATED ON ROOF EQUIP. NAMEPLATE. PROVIDE LIQUID TIGHT ® 23 CONTRACTOR TO PROVIDE MIN. 70 A 4' LONG CORD t= z o M FLEX CONN. TO UNIT. AND PLUG FOR ELEC. FRYERS (1 PER EACH). 0 0 N bi E RECEPTACLE SHALL BE, RECESSED POWERTITE a z ¢ PROVIDE GFCI PROTECTED 5-20R DUPLEX 100AMP ADJA1034-200 AT 18" A.F.F. g a RECEPT. INSTALLED IN WP BOX W/ WP COVER AT RTU. (TYP). 24 RAIN SENSOR 18" El PROVIDE 120V WIRING TO DUCT MOUNTED SMOKE DETECTORS AND REMOTE 2g LABEL ALL SWITCHES AND TIMERS ON OFFICE WALL TEST/INDICATORS FOR EXACT LOCATIONS OF DUCT DETECTORS, REMOTE INDICATORS 0 & TEST SWS. (SEE HVAC PLANS). Ag 26 NOT USED w 9 E.C. SHALL INSTALL AND WIRE RELAY CONTROL Q PANEL PACKAGE FOR HOOD EXHAUST FANS EF-1 2] COORDINATE KNEE WALL RECEPTACLE LOCATIONS AND EF 2. PROVIDE POWER AND INTERLOCK WITH GC TO ENSURE ACCESSIBLE AFTER FINAL Of CONTROL WIRING FOR HP1-F CONTROL PANEL INSTALLATION OF UNDER -COUNTER SHELVING d B-16 AND HOOD FIRE SUPPRESSION SYSTEM. SEE w D' HOOD FAN CONTROL INTERLOCK WIRING DIAGRAM. SHEET M2. MOUNT STARTERS AND CONTROLS ON cow C WALL P.O.S. NOTES: O 1 O "ON/OFF' SELECTOR SWITCH AND PILOT LIGHT F- I — IN NEMA 4X STAINLESS STEEL ENCLOSURE 1. ALL P.O.S. (POINT OF SALE) CIRCUITS SHALL HAVE 0 MOUNTED ON THE FACE OF THE HOOD. AN ISOLATED GROUND WIRE BACK TO THE PANEL. PROVIDED BY HOOD MFR. ALL P.O.S. EQUIP. SHALL BE WIRED w D_ 11 PROVIDE 2P30A NEMA 3R FUSED DISC INDEPENDENTLY OF ANY NON-P.O.S. EQUIPMENT. Q SWITCH & L.T. FLEX CONNECTION TO ROOF 2. ALL RECEPTACLES FOR P.O.S. EQUIPMENT SHALL >_ w B-26 MTD ICE MAKER COND UNIT, FUSE SIZE PER BE ISOLATED GROUND WITH SURGE SUPPRESSOR F— MFG'S NAMEPLATE DATA, TYPE. ALL RECEPTACLES FOR P.O.S. EQUIPMENT Ld C 12 PROVIDE WALL OUTLET W/ISOLATED SHALL BE SINGLE UNIT, UNLESS A DUPLEX 0 Z GROUND RECEPTACLES SUPPORTED FROM RECEPTACLE CAN BE USED TO SUPPLY TWO P.O.S. LLJ BLDG. LOCATE 6" BELOW CEILING. UNITS. DUPLEX RECEPTACLES MAY BE USED IN 2 STRUCTURE FOR VIDEO MONITOR/PRINTER THE MANAGER'S OFFICE FOR NON-P.O.S. Z & OR HEADSET. VERIFY EXACT EQUIPMENT (COMPUTER, MUSIC, FIRE ALARM, (' REQUIREMENTS & LOCATION. PROVIDE SECURITY, ETC-) J-BOX AND CONDUIT WITH PULL STRING FOR w 3. ALL CIRCUITS FOR P.O.S. EQUIPMENT SHALL BE 0 VENDOR DATA CABLES CONNECTED TO THE SAME PHASE OF POWER IN of 13 PROVIDE 3/4" x 18" H x 24" W PLYWOOD TELEPHONE THE PANEL. ALL BRANCH CIRCUIT BREAKERS w BOARD PAINTED WITH 2 COATS OF "LISTED" FIRE SUPPLYING P.O.S. EQUIPMENT SHALL HAVE F- 18 RETARDANT LIGHT GRAY COLOR PAINT. AT 96" A.F.F. LOCKING HANDLES DEVICES. 0 PROVIDE QUAD RECEPTACLE ADJACENT TO BOARD. Z B-41 Q PROVIDE # 6 CU, GROUND TO SERVICE ENTRANCE 4. EACH RECEPTACLE TYPE (LOCKING OR STRAIGHT GROUND, SEE DETAIL ARCHITECTURAL ELEVATIONS. BLADE) SHALL MATCH THAT OF THE EQUIPMENT In 24" FURNISHED. WHERE P.O.S. EQUIPMENT IS Z 4$ B-27 18 D FURNISHED WITHOUT PLUG THE RECEPTACLE w © 14 ROUTE CONDUITS DOWN IN WALL TO 125 AMP � P20 48 C-15 PANEL "PC" WITHIN PRODUCTION COUNTER TO SHALL BE LOCKING TYPE. COORDINATE IG SERVE EQUIPMENT, RECEPTACLE TYPES WITH THE P.O.S. EQUIPMENT 0 O u 31 Q4" SUPPLIER. 0 B-24 B-22 GENERAL NOTES w B-19 B-33 ' 1 rJ NOT USED c) WP GFI 24" Lu 4. 1 9 1 2 A. VERIFY RECEPTACLUNTING HEIGHTS OF ALL ES ES WITH EQUIPMENT SUPPLIED PRIOR ~ co 32 G2" J IG O J 4" 2 A-2216 TO INSTALLATION. 0 32" P30 co B. ALL EQUIPMENT ELECTRICAL OUTLETS ARE 2 P30 K72 DIMENSIONED TO CENTERLINE OF BOX FROM 0 P20 B-14 I I WP 102" ABOVE FINISHED FLOOR. }w} TO CENTERLINE OF OUTLET C. ELECTRICAL CONTRACTOR TO PROVIDE CORD 8, I- 17 BOX. 102" DENOTES MOUNTING PLUG CONNECTIONS FOR EQUIPMENT AS FOR DRIVE-THRU / HEIGHT ABOVE FINISHED W REQUIRED. 1L AUDIO SYSTEM SEE (TYPICAL -EXTERIOR F MENTBLDG. D. ALL DINING ROOM CEILING RECEPTACLES SHALL O DETAIL 4 THIS SHEET / / (TYPICAL -EXTERIOR OF BLDG) BE'WHITE' O_ w w 2 O AVERIFY P LOCATION ON SITE PLAN MENU BOARD AND 0 SPEAKER POST IQ ELECTRICAL POWER PLAN & DETAILS 9" - E2 j 1/4„_1,_0" 2'.2" i 1/ " 5-2, F-5112' 0 SEAL FEB 1 .� 202Q uj • NO 446 3 Z NOTE: � uj _. /LLI SAS _ REFER TO ARCHITECTURAL ELEVATIONS FOR J 0 Of ST E OF <(/�- EXACTION DIMENSIONED LOCATIONS FOR ALL WALL - (q �i 'c �_v EXTERIOR MENUBOARD II OUTLETS �� W ,\�,,� SEE SITE PLAN FOR _ D' ORIENTATION z I COORDINATE WITH SHEET K2 III FLO�iID1Y RELdW404 L�L �� 3u 1 X Lu CEILING GRID I I I I 1" CONDUIT U) / SPEAKER BOX - NOTE REFER TO MFR. LITERATURE LITERATURE FOR SPECIFIC INSTALLATION I INSTRUCTIONS FOR PREFAB LOOP I I 4' 0" r- ---,I I I i I 2-0" 7F_ 2' 6" MIN. L LOOP/AUDIO I PRE -FAB DETECTOR LOOP SUPPLIED & INSTALLED BY G.C. -TO BLDG L-----_____ FOR AUDIO — — — — CURB OMIT WIRE REINFORCING MESH IN CONC. DRIVE WITHIN 24" OF PREFAB LOOP ,'N� DRIVE-THRU LOOP DETECTOR E2 / NTS COORDINATE WITH 1-0 1/2" m n w0 J SIGNAL 4"x4" J-BOX II 'PROVIDE END OF FRYER 1'-10 2' 3 p tll STAINLESS STEEL COVER PLATE I WIRELESS DRIVE-THRU T- CENTER MODULE —11-- W/ 3/4" BUSHING HOLE FOR SIGNAL : OJ '. (WALL MOUNTED) OUTLET BOX" 27 I� N I I I L—It I I If _L_j 120 VOLT DUPLEX v RELEASE DATE 1 COMMENT RESPONSE 03/28/19 2 KITCHEN REVISION 06/26/19 3 OWNER REVISION 01/02/20 4 5 6 CIRCUIT B-22 yyy 1 77� PROJECT N0. II 2018-002 4L- 2\a^xa^ J-BOX 3ISSUE DATE LOOP DETECTOR `—COUNTER TOP 12/21/18 3/4" CONDUIT TO MENU BOARD OJOAND SPEAKER POSTFIN. FLOOR VERIFY LOCATION DRAWN CHECKED �ON SITE PLAN.___—_JC JC SHEET NO'2" y:, 5'-111/2" 2'-0" 3'-4112" 2'-6" 2'-33/4" 3'-4" 1'-it" 1'-3" 1'-11" 10" 6'-2" 4 DRIVE-THRU AUDIO / TIMERS 6 ELECTRICAL RECEPTACLE LOCATION 71/2" 7" 8" E2 NTS E2 1/4„=1:_0„ ZJ _E 2 Z Lij f-1� L- W ui > Fnn.I._ Y..1� w Z Q 0- PANEL MANUFACTURER: ]-LINE MAIN BREAKER (AMPS): 800 MAIN LUGS (AMPS): K.A.I.C.: 22 MOUNTED: RECEBED NAME: PANEL "DP" 3 PHASE 4 WIRE PROJECT NAME: POPEYES 120/208 VOLTS PROJECT NUMBER: 2018-002 FED FROM: TRANSFORMER O T 3 E Q T A G CKT NO, IDENTIFICATION WIRE/COND C O D E LOAD/PHASE (AMPS) CIRCUIT BREAKER LOAD/PHASE (AMPS) C O D E WIRE/COND IDENTIFICATION CKT NO. E Q T A G O T 8 A B C TRIP P P TRIP A B C B10 1 CONY. OVEN 7 3#10, 1#10G, VC K 24,0 30 3 3 70 56.0 K 3#4, 1#8G, 1"C ELEC, FRYER 2 A1l,U 5 3 24.0 56.0 4 5 24.0 56.0 8 BID 7 CONY. OVEN 3#10, 1#10G, 1"C K 24.0 30 3 3 70 56.0 K 3#4, 1#8G, 1"C FILED.. FRYER 8 Al tU 5 9 24.0 56.0 10 11 24,0 56.0 12 5 A11.0 13 ELEC. FRYER 3#4, 1#8G, VC K 56.0 70 3 3 70 56.0 K 3#4, 1#8G, VC ELEC. FRYER 14 A11.0 5 15 56,1 56.0 16 17 56.0 56.0 18 19 PANELA 4#4/0, 1#4G, 2-12"C O 143.0 225 3 3 60 49.0 C WE, 1#10G, VC RTU-1 20 21 135S 49.0 22 23 140.8 49.0 24 25 PANEL B 4#4I0, 104G, 2-12"C O 140.4 225 3 3 60 49.0 C 3#6, 1#10G, 1"C RTU-2 28 27 126.4 49.0 28 2g 49.0 30 31 PANEL C 4#410, WG, 2-12"C 150.7 225 3 3 60 49.0 C 3#5, 1#10G, VC RTU-3 32 33 139.3 49.0 34 35 138,0 49.0 36 5 Al l.0 37 ELEC. FRYER 3#4, 1#8G, VC K 70 3 3 70 56.0 K 3tt4, l#8G, 1"C FLED. FRYER 38 A11.0 5 39 58.0 56.0 40 41 56.0 56.0 42 594.1 1 561.5 1 570. 3 PHASE W AMPS: 9B6A0 PRASE'E AMPS: 93Z.47 PHASE'C' AMPS: 941.73 LIGHTING (L) RECEPTACLES (R) KITCHEN EQUIPENT (K) LARGEST MOTOR (M) A/C COOLING (C) OTHER (0) COW LOAD (AMPS) DEMAND FACTOR DEMAND LOAD (AMPS 97.4 1.25 121.75 204.7 NEC 144.00 756.6 NEC 491.81 81.5 1.25 101,88 147.0 1 1.00 147.00 169.0 1 1.00 1169.00 1 371.0 1 371.0 1 371.0 1 PANEL MANUFACTURER NQOD MAIN BREAKER (AMPS): WIN LUGS (AMPS): 225 K.A.I.C.: 22 - MOUNTED: RECESSED NAME: PANEL"B" 3 PHASE 4 WIRE PROJECT NAME: POPEYES 120/208 VOLTS PROJECT NUMBER 2018-002 FED FROM: PANEL DP N 0 T E S E Q T A G CKT IDENTIFICATION WIRE/COND C 0 D E LOAD/PHASE (AMPS) CIRCUIT BREAKER LOAD/PHASE (AMPS) C 0 D E WIRE/COND IDENTIFICATION CKT CKT E O T A C' N 0 T E S A B C TRIP P P TRIP A B C 2 1 RTU RECPT & DUCTS 2012, 1#12G, 314" C R 3.0 20 1 1 20 6.4 L 2#12, 1#12G, SAV C DINING LIGHTS 2 3 2 3 DIGITAL MENUBOARD 2012. 1#12G, 3/4" C R 8.3 20 1 1 20 4.3 L 2#12, 1#12G, 3/4" C PENDANT LIGHTS Q 1 1 3 3 5 COUNTER/ RESRTOOM LIGHT 2#12, 1412G, 3/4" C L 3.0 20 1 1 20 5.0 R 2#12, 1#12G, 3/4" C TELEPHONE BOARD 6 2 3 7 KITCHEN LIGHTS 2#12, 1#12G, 3/4" C L 8.0 20 1 1 20 3.0 1 R 2#12, 1#12G, 3W C RECEPT OFFICE 8 2 2 A48.1 9 REFRIG. BATTER 2#12, 1#12G, 3/4" C K Z3 20 1 1 20 4.5 R 2#12, 1#12G, 3/4" C MUSIC SOUND 10 2 N31 11 WATER HEATER 3#4 1#BG, VC M 50.0 70 1 3 1 1 20 4.5 R 2#12, 1#12G, 3(4" C COMP/ PRINTER 12 2 13 50.0 1 20 15.0 R 2#12, 1#12G, 3/4" C D/TWINDOW 14 15 50.0 1 20 15.0 R 2#12. 1#12G, 3/4" C SHOW WINDOW 16 3 17 FRONT SIGN 2#12. 1#12G, 3/4" C L 10.0 20 1 1 20 4.5 K 2#12, 1#12G, 3/4" C D/T MENUBOARD 18 3 2 1 1 18 IVIDEO MONITOR 2#12. 1#12G, 3/4" C R 9.0 20 1 1 20 0.8 L 2#12, 1#12G, 3/4" C TIME CLOCK 20 11 2 3 21 PYLON SIGN 2#8, 1#10G, 1" C L 10.0 20 1 1 20 1 1 6.0 R 2#12, 1#12G, 34" C D/TAUDIO 22 23 SHOW WINDOW 2#12, 1#12G, 3/4" C R 1 15.0 20 1 1 20 5.0 R 2#12, 1#12G, 3/4" C ROB SYSTEM/ PRINTER 24 4 2 25 SECURITY SYSTEM 2#12, 1#12G, 314" C R 3.0 20 1 1 20 15.0 R 2#12, 1012G, 3/4" C SHOW WINDOW 26 4 27 POS SYSTEM 2#12, 1#12G, 314" C R 4.5 20 1 1 20 6.5 L 2#12, 1#12G, 3/4" C EXT. LIGHTS 28 3 29 UNDER COUNTER SAFE 2#12. 1#12G, 3/4" C R 3.0 20 9 1 20 66 L 2#12, 1#12G, 3/4' C EX1. LIGHTS 30 3 2 31 COMPUTER/ PRINTER 2#12. 1#12G, 3/4" C R 10.0 20 1 1 20 9.8 L 2#12, 1#12G, 3/4" C EXT. LIGHTS 32 3 K32 33 SODA DISPENSERS 2#12, 1#12G, 3/4" C K 4.0 20 1 1 20 6.5 L 2012, 1#12G, 3/4" C WALL ART LIGTS 34 3 5 35 WALK IN FREEZE COMP 3#42, 91213, 3/4" C K 5A 20 3 1 20 5,0 L 2#12, 1#12G, 314" C DIGITAL PRE SELL 36 2 37 5.4 1 20 8.0 R 2#12, 1012G, 34" C. POS SYSTEM 38 4 39 5.4 SPACE QO 41 SHOW WINDOW 2#12, 1#12G, 3/4" C R 15.0 20 1 SPACE Q2 966.10 :LARGEST CONNECTED PH. "AMPS' 347.28 :LARGEST CONNECTEDPH. "KVA" PHASE 'WAMPS: 143.40 PHASE WAMPS: 126.37 684.33 :LARGEST DEMAND Pi. "AMPS' PHASE C' AMPS: 191.90 246.25 :LARGEST DEMAND Pi. "KVA" NOTES: 1. EQUIPMENT GROUNDING 2. LOCK ON BRPAKER 3. VIA TIME CLOCK 4. ISO GROUND 5. PROVIDE BUILT IN SHUNT TRIP BRKR CAPABILITY PANEL MANUFACTURER: NQOD NAME: PANEL "A" MAIN BREAKER (AMPS): 3 PHASE MAIN LUGS (AMPS): 225 4 WIRE PROJECT NAME: POPEYES K.AJ.C.: 22 120/208 VOLTS PROJECT NUMBER: 2018-002 MOUNTED: RECESSED FED FROM: PANEL DP N O T S E Q T A G CKT NO IDENTIFICATION WIRE/COND C O D E LOAD/PHASE (AMPS) CIRCUIT BREAKER LOAD/PHASE (AMPS) C O D E WIRE/COND IDENTIFICATION CKT NO. E Q T A G JE A B C TRIP P P TRIP A B C 1 FRYER HOOD EF-1 2#12, 1#12G, 3/4" C M 11.0 20 1 t 1 20 5.0 M 2#12, 1#12G, 3/4" C EF3 2 3 FRYER HOOD EF-2 2#12, 1#12G, 3W C M 11.0 20 1 1 20 2.5 0 2#12, 1#12G, 314" C HOOD CONTROLS 4 2 K42 5 ICARBONATOR 2#12, 1#12G, 3/4" C K 14.4 20 1 1 20 10.5 R 2#12, 1#12G, 314" C KITCHEN CONY. RECEPT 6 A31 7 MARWATOR 2#12, 1#123, 3/4" C K 5.0 20 1 1 20 0.8 R 2#12, 1#12G, 3/4" C OFFICE CAB, FAN 8 2 2 C10.27 9 SANDWICH 2#12, 1#12G, 314" C K 6.5 2D 1 1 20 DS 0 2#12, 1#12G, 3/4" C SERVICE DOORBELL 10 C20 11 TOASTER 2#12, 1#12G, 3/4" C K 12.5 20 1 1 20 5.0 O 2#12, 1#12G, 34" C IRRIG CONTROLS 12 2 C30 13 PRODUCT HOLD 2#12, 1#12G, 3/4" C K 4.5 20 1 1 20 5,0 O 2#12, 1#12G, 31T C ANUSL SYSTEM 14 2 2 A54 15 FREEZER 2#12. 1#12G, 3/4" C K 12.0 20 1 1 20 5.0 K 2#12, 1#12G, 3/4" C REFRIGERATOR 16 B60 2 2 E10 17 FREEEZER EVAP 2#12, 1012G, 314" C K 13.3 20 1 1 20 L5 R 2#12, 1#12G, 34" C RECEPT DINNING 18 2 A48.2 19 REFRIG. BATTER 2#12, 1#12G, 3/4" C K 2.3 20 1 1 20 9.0 R 202, 1#12G, 3/4" C RECEPT DINNING 20 21 ISPARE 20 1 1 20 50 O 2#12 1#12G, 314" C SECURITY CAMERA 22 2 D90 23 HOLD CABINET 2#12, 1#12G, 3/4" C K 175 20 1 1 20 4.5 L 2#12, 1#12G, 314" C COOLER/FREEZR LIGHTS 24 1 1 2 D81 CHUB WARMER 2#6, 1010G, 3/4" C K 4Z6 602 2 30 16.8 K 2#10, 1#103, 3/4" C MICROWAVE D20 27 476 166 28 D30 31 PRODUCTASSEM 2912, 1012G, 34" C K 5.2 20 1 11 20 8.3 K W2, 1#12G, 3'4" C HEAT TRACE FRZ 30 E10 2 5.2 20 1 1 20 9.3 L 204, 1#6G, 1"C SITE LIGHTING 32 3 33 SPARE 1 20 7.0 L 2#6, 1#6G, VC SITE LIGHTING 34 3 F15.1 37 HEATED HOLDING UNIT 2#10, WOOL 1" C K 18,8 25 2 1 20 4.5 M 2#12, 1#12G, 3/4" C COOLER EVAP 36 E10 2 18.8 3 20 5.2 K 3#12, 1#12G, 3�4" C WALK IN COOLER COMP 38 5 D20 39 41 MICROWAVE 2#10, 1#10, 3/4"C K 16.6 30 2 5.2 q0 1ss s.z 42 PHASE W AMPS: 146.30 PHASES' AMPS: IM-80 PHASE 'C'AMPS: 140.83 LIGHTING (L) RECEPTACLES(R) KITCHEN EQUIPENT (K) LARGEST MOTOR (M) A/C COOLING (C) OTHER (0) PANEL MANUFACTURER: NQOD MAIN BREAKER (AMPS): MAIN LUGS (AMPS): 125 K.A.I.C.: 22 MOUNTED:RECESSED 94.4 1 93.7 98.3 CONN, LOAD (AMPS) DEMAND FACTOR DEMAND LOAD (AMPS 20.8 1.25 26.00 24.8 NEC 24.80 211.3 NEC 137.36 31.5 1.25 39.38 0.0 1.00 0.00 18.3 1 1.00 18.30 50.9 42.1 425 145.30 LARGEST CONNECTED PH "AMPS" $2.28 '.LARGEST CONNECTED PH. "KVA" 94.41 LARGEST DEMAND PH. "AMPS" 30.37 LARGEST DEMAND PH. "KVA" NAME: PANEL "PC" (PROVIDED BY EQUIPMENT SUPPLIER) 3 PHASE 4 WIRE PROJECT NAME: POPEYES 120/208 VOLTS PROJECT NUMBER: 2018-002 FED FROM: PANEL C N E E N Q C C Q O Q CKT O LOAD/PHASE (AMPS) CIRCUIT BREAKER LOAD/PHASE (AMPS) O CKT IDENTIFICATION WIRE/COND WIRE/COND IDENTIFICATION ET NO D D NO. T E A E E A S G G S A B C TRIP P P TRIP A B C 1 13.9 1 20 5.1 L 2#12, 1#12G, 3/4'C HEAT LAMP 2 H10.4DP D92 HOLDING CABINET 2#12,1#12G, 3/4" C K 20 2 g 139 2 30 237 K 2#10, 1410, 3/4"C HOLDING CABINET D94 139 237 6 D92 HOLDING CABINET 2#12, 1#12G, 3PVC K 20 2 7 13.9 3 35 26,0 K 3#10, 1#10G, VC HOLDING BIN 8 093 J40 9 UC REFRIG. 2#12, 1#12G, 3/4" C K 54 20 1 28.0 10 17 SPACE Z6.0 12 PHASE'W AMPS: 86.90 PiASE'6 AMPS' 70.00 PHASE'C'AMPS: 03.60 LIGHTING (L) RECEPTACLES (R) KITCHEN EQUIPENT (K) LARGEST MOTOR (M) A/C COALING (C) OTHER (0) y'�A�!•iK1-1 CONN. LOAD (AMPS) DEMAND FACTOR DEMAND LOAD (AMPS 5.1 1.25 6.38 32.4 NEC 32.40 51.5 NEC 33.48 0.0 1.25 0.00 0.0 1.00 0.00 0.01 1.00 1 0.00 1. EQUIPMENT GROUNDING 2. LOCK ONBREAKER 3. VIA TIME CLOCK 4. ISO GROUND 5. SHUNT TRIP BREAKER 70.00 LARGEST CONNECTED PH. "AMPS' 25.19 :LARGEST CONNECTED Pi. "KVA" 63.25 LARGEST DEMAND PR. "AMPS" 19.16 :LARGEST DEMAND Pi. "KVA" Z WS ^G L.L D a W 0 ui \ �/ / L#�J� F - w Z Q a_ A LIGHTING (L) RECEPTACLES (R) KITCHEN EQUIPENT (K) LARGEST MOTOR (M) A/C COOUNG (C) OTHER (0) 86.4 1 84.6 1 101.4 CONN. LOAD (AMPS) DEMAND FACTOR DEMAND LOAD AMPS 73.8 1.25 92.25 150.9 NEC 145.50 16.2 NEC 10.53 50.0 t25 62.50 0.0 1.00 0.00 0.0 1.00 1 0.00 1. EQUIPMENT GROUNDING 2. LOCK ON BREAKER 3. VIA TIME CLOCK 4. ISO GROUND 5. HACR TYPE CIRCUIT BREAKER 57.0 1 41.8 1 30.5 PANEL MANUFACTURER: NQOD NAME: PANEL"C" MAIN BREAKER (AMPS): 3 PHASE MAIN LUGS (AMPS): 225 4 WIRE PROJECT NAME: POPEYES K.A.I.C.: 22 1201208 VOLTS PROJECT NUMBER: 2018-002 MOUNTED: RECESSED FED FROM: PANEL DP 143.40 : LARGEST CONNECTED PH. "AMPS" 51.00 :LARGEST CONNECTED PH. "KVA" 183.51 : LARGEST DEMAND PH. "AMPS" 58.77 : LARGEST DEMAND PH. "KVA" N O T E S E Q T A G CKT NO. Ile- IDENTIFICATION WIRE/COND C O D E LOAD/PHASE (AMPS) CIRCUITBREAKER LOAD/PHASE (AMPS) C O D E WIRE/COND IDENTIFICATION CKT NO. E Q T A G N O T E S I 6 1 FRYER CONTROLS 2#12, 1#12G, 3/4" C K ETS 20 1 1 125 58.9 0 4#1, 1#6, 1 -117C PANEL PC 2 3 SHUNT TRIP 706 4 3 A92 5 HEATTRACEBOSS 2#12,1#12G,3/4"C O 10.0 20 1 63.6 6 K71 7 TEA BREWER 2012, 1#12G, 3/4" C K 14.0 20 0 1 1 2 V 8 A V #1 12 4" 1 20 1 1 20 5.0 R. 2#12, 1#12G, 3/4" C POS TERMINAL 10 4 D70 11 HOT WATER DISP 2#10, 1#10, 3/4"C K 16.8 30 2 3 20 10:7 M 3#12,1#12G,1"C ICECOMPRESSOR 12 KID 13 18.8 10.7 14 K31 F 15 SODA DISPENSERS 2#12, 1#12G, 3/4" C K 5,0 20 1 10.7 18 17 SPARE 20 1 1 20 4.5 K 2#12, 1#12G, 3X' C BISCUIT HOLD 18 B65 19 GREASE COL. SYSTEM 2#12, 1#12G, 3/4" C K. 10,0 20 1 20 D70 21 HOT WATER CISP 2#10, 1#10,.3/4"C K 158 30 2 22 24 25 26 27 28 LIFT STATION 300, 1#10, VC 0 8.0 20 3 SHUNT TRIP 30 31 8.0 3 20 8,0 O 3#10, 1#10G, VC LIFT STATION 32 33 8.0 50 34 35 ISPACE 8.0 36 37 SPACE SPACE 38 d 39 SPACE SPACE 40 41 SPACE ISPACE 42 1 TIME CLOCK INTERIOR � LC1 LIGHTING CIRCUITS TO BE ROUTED VIA TIME SWITCH CONTROLLED CONTACTOR ! , PHASE'W AMPS: 150.70 PHASE M AMPS: 139.30 PHASE 'C' AMPS: 138.00 4 - #4/0, THWN, CL # 4 CU GND IN 2 1/2" CONDUIT PANEL „PC„ LIGHTING & RECEPTACLES(R; KITCHEN EQUIPENT (K; LARGEST MOTOR (M; A/C COOLING (q OTHER (U, 1 57.1 1 456 1 51.2 1 CONN. LOAD (AMPS) DEMAND FACTOR DEMAND LOAD (AMPS 58.9 1.25 73.63 32.0 NEC 32.00 138.8 NEC 90.22 8.0 1.25 10.00 0.0 1.00 0.00 0.0 1.00 0.00 PANEL PANEL PANEL 4 - #4/0, THWN, CU UNDERGROUND # 4 CU GND CONDUIT IN2112"CONDUIT 93.6 93.] 1 85.8 150.70 :LARGEST CONNECTED PH. "AMPS" 54.23 :LARGEST CONNECTED Pi. "KVA" 118.85 :LARGEST DEMAND Pi. "AMPS" 42.77 :LARGEST DEMAND Pi. "KVA" - - - - - - ENGRAVED SIGNN �� "MAIN DISCONNECTN IDENTIFICATION PLAQU METER LISTED FOR I AVAILABLE MAIN WP O PANEL FAULT CURRENT 313800A CT & S/N PROVIDE & INSTALL "DP" I ENCL. BREAKE CT CABINET AND 800A M.C.B NEMA 3R METER IN ACCORD WITH I -LINE POWER CO REQUIREMENTS 3 SETS OF 4- #350 KCMIL, THWN, CU, EACH IN 1 #2/0 CU EQUIP. BOND � � 3 1/2" CONDUITS VIA CT CABINET TO TO PAD PER N.E.C. ARTICLE 250,92 MOUNTED TRANSFORMER. GC / ELECT. AND TABLE 250.66 CONTRACTOR SHALL COORDINATE SERVICE (3) SETS OF 4 - #350 KCMIL, THWN, CU #1/0 CU GND EACH IN 3 1/2" CONDUITS. #6CUGND Q IN 1 1/2" CONDUIT ELECTRICAL POWER RISER DIAGRAM E3 / 1/4"=1'-0" -L REBARS IN FOUNDATION SINGLE POINT PER LOCAL UTILITY CODE. GROUND I FAULTCURRENT po FROM XFMR 10 RUN #210 CONDUCTOR TO 5/8 " 3/4"C-1 #2/0 CU BOND TO DIA. x 10'-0" LENGTH GROUNDING MINIMUM OF ONE OR COLD WATER PIPE PER ROD. GROUNDING TO CONFORM TO MORE GROUNDING N.E.C. ARTICLE 250.52 (A) SECTION 250-50 (KE.C.) METHODS SHALL BE USED (1) AND 250.53 (D) WITH #2/0 CU UU W U O a- LU W W_ W Co O F- F- O Z W O_ } W F- U.1 U Z W 2 Z OD On W W' LU 2 H Z a (n F- Z W U O W U) W F- O F- H S (D O_' LU W a O a LU W 2 O J J a Z H 2 OD E } D_ O U H Co W > O_ W (n W } J (n (n W D_ d X W (n J 2 N V N m M O� U M M M W m N L� ¢ N z a _= M p E LL I- W z (D L.L Z Q W J � J m � J U m Z w O a _U T CD H_ Z o L_v W � U N N U <n W o v o.." V5 M y N C U Z W o Q J m J U)a W ¢ J W = U ~ N rn H W Q LU W W i > O W N O U � popeYes W 0 U) J rn Z W F W U 11 CV r- N LU d Y O vo MCLCHJC UAIC COMMENT RESPONSE 03/28/19 2 KITCHEN REVISION 06/26/19 3 OWNER REVISION 01/02/20 4 5 6 PROJECT NO. 2018-002 ISSUE DATE 12/21/18 DRAWN CHECKED JC JC / SHEET NO e E3 h