BUILDING PLAN PAGE 1-13
0 13 14 6 1/2" THREADED ROD SHALL PASS THRU ROOF CURB ASSEMBLY FOR DIRECT FASTENING OF RTU ENCLOSURE TO BUILDING STRUCTURAL STEEL. (TYPICAL EACH CORNER OF RTU). ROOF CURB INSULATED SUPPLY DUCT WHEN SHOWN IN PLANS INSTALL 2"x2"x1/4" - STEEL ANGLE BOLTED PARALLEL TO MOUNTING TABS ON DROP BOX FIELD ORIENTED LOUVERS AT 30' U,N.O. INCLUDE ONE VISIT FOR FIELD ADJUSTMENT AFTER CERT OF OCC. RTU EQUIPMENT TACK WELD BOLT HEAD TO CURB ROOF CURB BY EQUIPMENT MANUFACTURER 3/8"0 THREADED ROD WITH NUT AND FLAT WASHER AT EACH ENE Air System Sizing Summary for RTU-1 Name: DO FORT PIERCE 9100A 08/ 'd by: ZFP 0 .Air System Information Air System Name ......................... .......... _..... RTD-1 Number of zones ......... ................. ......... ,................. ...... 1 Equipment Class ........................... ........ PKG ROOF Floor Area ........ ........................ ft' ......... ._........ash. Air System Type ........... .......... ....... .............. 3ZCAV Location ........................... Florida ... West Palm Bach, Florida .Sizing Calculation Information Calculation Months ................"..,,..,"..,.,.". Jan to Dec Zone CFM Sizing .............. Sum of space airflow rates Sizing Data ............... ................ ,............ Calculated Space CFM Sizing ........... Individual peak space loads Central Cooling Coil Sizing Data Total coil load ......... ............ ............ ................. .... ilia Tons Load occurs at ................................... _........... . Ju11500 Total coil load .................... ..........__........,..",.. 111.5 MBH OADB/WB......... ,,............,..... .... ....,..... ,...,... 91.0178.0'F Sensible it load ................ .......... ..... ........... .... 65.3 MBH Entering OB I WB.,..,...... ...................... .......... 80.2170.0 'F Coil CFM at Jul 1500 ..... ...... 2719 CFM Leaving DB / WB ..... 58,0 1572 °F Max block CFM ... ..... ........ 2719 CFM Coil ADP ....... .. ................... ..,......... 55,6 'F Sum of peak zone CFM . ... ..._. 2719 CFM Bypass Factor ..... ........... 0.100 Sensible heat ratio .... ... .., 0.585 Resulting PH . ..... ............. 6o is ft'/Ton ... _. ., 467.5 Design supply temp ...... .... 58.0 F BTU/(hFft') ... ... 25.7 Zone Tsat Check ....._ .... ll OK Waterflow@100'Fnse ...... .,.... NIA Max zone temperature deviation ..,. .... 0,6 °F Central Heating Col Sizing Data s Max coil load ,.... _ .... 47,7 MBH Load occurs at .. Des HIS Cal CFM at Des Htg ... .. ., 2719 CFM BTIJI(hr-W) .... ......... 110 Max coil CFM .... .. .. 2719 CFM Ent. DB / Lvg DB ........................................ 59,8 176.1 F Water flow@20.0 Fdrop ............ .. .. .... NIA Supply Fan Sizing Data Actual max CFM....... ................... ...................... 2719 CFM Fan motor BHP....,..:.............................,................. 0.00 BHP Standam CFM..... ...... .. 2717 CFM Fan motor kW .... ,. .. ... 0.00 kW Actual max CFM/ft' ..................................... 0.63 CFM/0' Fan static ...... .:. ........... .. ,. ... 0.00 Inwg Outdoor Ventilation Air Data Design airflow CFM ,.... .......... loot CFM CFMlparson .. ........... .......... 1547 CFM/person CFMift' ......... ....., ...... 0.23 CFM/I`' Hourly Analysis Program v4,90 t'asle 1 of 2 ROOF TOP UNIT RTU SHALL BE BOLTED THROUGH ROOF CURB TO BLDG STRUCTURAL J z STEEL WITH 1 /2" IL ALL THREAD. lL 7TRETURN AIR DUCT RETURN AIR PLENUM ABOVE BOTTOM OF JOISTS RETURN AIR OPENING TO CONNECT TO DROP BOX 3/8" THREADED FASTEN DROP BOX ROD DIFFUSER TO SUPPLY AIR DUCT TRANSITION DIFFUSER TO BE SPECIFIED BY NATIONAL ACCOUNT EQUIPMENT VENDOR. BOTTOM OF DIFFUSER SHALL BE 12'AFF ROOFTOP / DROP DOWN DIFFUSER DETAIL SCALE: NONE 2 GA, x 1/2" SS STRAPS INSTALLED @ 2' O.C. MAXIMUM EPERATION ALONG PERIMETER OF CURB. EXTEND LENGTH F STRAPPING 1" BEYOND SCREWS '10 SELF -TAPPING SS SCREWS D EACH TIE -DOWN STRAP. /8"0 SS BOLT AT EACH STRAP WITH FLAT WASHER EACH ND. DRILL THROUGH CURB SO THAT CENTERLINE OF HOLE i 3/4" ABOVE BOTTOM OF 2x4. "ROOF LINE METAL DECK AND JOIST 2 RTU CURB INSTALLATION DETAIL M2 SCALE: NONE Air System Sizing Summary for RTU-2 Project Name: DO FORT PIERCE 9f00A 062 Prepared by: ZFP 05:07 OS'WP Air System Information Air System Name ._.......... ........... ... _............ RTU-2 Numberofzones...:.,._,..._ :................................. ...... _. 1 Equipment Class ................................... PKG ROOF Floor Area .......... ................... ........... ..._..,,.... ,...... 4302.0 ft° Air System Type . ....... .................................. . SZCAV Location .............................. West Palm Beach, Florida Sizing Calculation Information Calculation Months ..............._ ................ Jan to Dec Zone CFM Sizing ............... Sum of space atflow rates Sizing Data ................. ......................... .. Calculated Space CFM Sizing ......... individual peak space loads Central Cooling Coil Sizing Data Total coil load ............................... ,................. ..... . 9A Tons Load occurs at ..................................... _.. _...._ Jul 1500 Total coil load ................................................... 112.4 MBH OAOB/WB_.......,,......,............................_... 91.0178.0 °F Sensible .11 load................................ ............... 66.4 MBH Entedng DB / WB .. .. 80 0 / 69s °F Coil CFM at Jul 1500 .. .2797 CFM Leaving DO/WB .. ., 58,0157.2 °F Max black CFM ............... ... .... 2797 CFM Coil AOP .. ............ 55.6 °F Sum of peakmne CFM .. .... 2797 CFM Bypass Factor ... .... ._ .. 0.100 Sensible heat ratty ....__..... ....................... 0,591 Resulting RH ....... ......... ...... 60 % fFrrOn ..._ ... ...459.1 Design supply temp 50.0 °F BTterfloF) . ........................._. Zoneoneat Check .re ....... 0of5 OK. Water flow@100 'F rise .. 0 WA ... N/A Max zone temperature deviation ....... .. .... 0.5 °F Central Heating Coil Sizing Data Max coil load ..... ...... 43.2 MBH Load occurs at .... .. , . Des HIS Coil CFM at Des HgO ..... ..... 2797 CFM BTU/{hr ft') ... ............................ 10.0 Max still CFM _... .. _ ...,"2797 .CFM Ent. DB/Lvg DS................. ......... 60.2/74.5'F Water Flow@20.0°Fdrop . ._...... NIA Supply Fan Sizing Data Actual max DFM .. ... 2797 CFM Fan motor BHP . 0.00 BHP Standard CFM .. .... 2796 CFM Fan motor kW .. .. 0.00 kW Actual max CFMM ...... .., .. ... 0.65 CFM/ft' Fan static ..... ...... ........ 0.00 in wg Outdoor Ventilation Air Data Design airflow CFM ...................... ...................... 985 CFM CFM/person ................... ........-. "........ , 14.71 CFM/person CFMfft' ,...... ........ " .... ............ .............. 023 CFM/f 1 Hourly Analysis Program v4.90 Page 2 of 2 12 GA, AIRCRAFT CABLE )AD RATED FASTENERS SUSPEND EXHAUST HOUSING STRUCTURE WITH STEEL BA AT EACH CC nl lnTUTAM/ _ SEE SIZING BACKDRAFT DAMPER CEILING EXHAUST WITH \ \ FINISHED CEILING REMOVABLE GRILLE FOR � ' SEE ARCHITILING ACCESS TO AND SERVICE OF RAL BLOWER ASSEMBLY DWG'S FOR TYPE �\ CEILING MOUNTED EXHAUST FAN M2 SCALE:NONE\ SCALE:NONE ADJUSTABLE PIPE ROLLER SUPPORT CLAMPING NUT WITH NUT 1-5/8"x1-5/8"x12 GA STEEL AND WASHER (TYP)� CHANNEL. SECURE TO ROOF CURB WITH XX"O LAG BOLTS 1"x 22 GA. STEEL STRAP, COORDINATE SIZE WITH SMACNA GUIDE 10" DIA. AND UNDER ROUND DUCT 3'� ROUND DUCT HANGER DETAIL M2 J SCALE: NONE LOCKING QUADRANT TO BE EXPOSED AND ACCESSIBLE TIE TO STRUCTURAL SUPPORT FLEXIBLE DUCT WITH 1" THICK INSULATION AND VAPOR BARRIER MAX. RUN TO BE 8'-0" (MINIMUM R VALUE = 4.2) TIE TO STRUCTURAL SUPPORTS r 2" WIDE METAL BAND SUPPORT (TYPICAL) / SQUARE TO I I NYLON DRAWBAN D AND MASTIC ROUND ADAPTER AT EACH CONNECTION (TYPICAL) BLANKET TYPE INSULATION SUSPENDED TYPE LOUVERED FACE CEILING CEILING SYSTEM DIFFUSER WITH 2' X 2' NOTE: FOR BRANCH DUCT CONNECTIONS IN EXCESS OF 8'-0" PROVIDE RIGID ROUND DUCT TO WITHIN 6'-0" OF DIFFUSER AND CONNECT WITH FLEXIBLE DUCT. TYP. DIFFUSER & BRANCH CONNECTION SCALE: NONE GALVANIZED STEEL ROD OR STRAP SUPPORTS PER SMACNA STANDARDS SHEET METAL SUPPLY DUCT WITH 2" THICK WRAP INSULATION. SPIN -IN TAP FITTING WITH AIR SCOOP & DAMPER AND MASTIC AT FLANGE. 1-1/2" x 1-1/2" x 1/8" GALVANIZED ANGLE OR STRAP PER SMACNA ROOF WIR11111111114lyr ROOFTOP PIPE SUPPORT DETAIL SCALE: NONE FROM RTU 3" FLEXIBLE CANVAS CONNECTION (TYP.) HORIZONTAL AIR SCOOP ROUND SUPPLY AIR DUCT. CONNECT BRANCH TO SUPPLY AIR DUCT DROP, ABOVE CONCENTRIC DIFFUSER. VOLUME DAMPER RIGID DUCT DROP (FLEXIBLE DUCT NOT ALLOWED) TO DROP DIFFUSER N OTE: INSTALL HORIZONTAL AIR SCOOP HAVING A CONTINUOUSLY CURVED CROSS SECTION AND BALANCING DAMPER AT DUCT CONNECTION TO DIVERT SUPPLY AIR INTO THE CONNECTED DUCTWORK. LENGTH OF SCOOP SHALL BE LIMITED TO THE WIDTH OF THE SUPPLY AIR ANNULAR SPACE. SUPPLY BRANCH DETAIL M2 SCALPE NONE 6" MAXIMUM 1-1/2" X 1-1/2" X 10 GAUGE MINIMUM ANGLE IRON AROUND CLEARANCE BETWEEN FIRE DAMPER AND WALL SHALL BE 1/8" PER FOOT OF PERIMETER. / MIN 1" LAP d AROUND ENTIRE OPENING BOLTS 1-1/2" ANG DUCT NUT OR BOLT OR WELDED c o SHEET METAL HINGED ACCESS DOOR SCREW WITH CAM FASTENER AND NEOPRENE GASKET 10 GAUGE MINIMUM SIZE 6 X 6 SLEEVE a a "S" SLIP TYPE WITH SHEET METAL SCREWS NOTE: PROVIDE FIRE DAMPER FOR ROUND DUCT OR USE TRANSITIONS FOR ROUND TO SQUARE DUCT. FIRE DAMPER DETAIL M2 SCALE: NONE 1 I � r" ° 9 10 I 1 1i 12 13 14 15 I' 16 t` I M L'a�00 M 01 OM Cn as try Vi O N W a;NrwOw .cd coo i:r^ •` [-ll U ii weew Z� U a� ow 3 �a A � o i N to ri N 4 aw F,i ✓� o� O 00 �. � lingo M M O W °� w L-1 H ' I 0 y� M PROJECT NO: 20-xxx DRAWN BY: T.OWENS CMCD BY: G.W. STEWART SHEET NO: MECHANICAL N DETAILS M3 POWER & LIGHTING LEGEND ALL ABBREVIATIONS SHOWN MAY NOT APPEAR IN DRAWINGS. o LIGHT FIXTURE, STRIP, OVERHEAD / WALL MOUNTED. LIGHT FIXTURE, OVERHEAD / WALL MOUNTED, EMERGENCY. ❑/0/0 LIGHT FIXTURE, 2X2, 10, 2X4. 0/v/0 UGHT FIXTURE, 2X2, 1X4, 2X4. NIGHT LIGHT. �f EMERGENCY BATTERY PACK FIXTURE, WALL / CEILING MOUNTED. 0/0/ Q LIGHT FIXTURE, SURFACE MID. / RECESSED / WALL MOUNTED, ♦/Q/ Q LIGHT FIXTURE, SURFACE MTD. / RECESSED / WALL MOUNTED. W/ BATTERY BACKUP. 01 / Il�I EXIT SIGN, CEILING/WALL MOUNTED. PROVIDE ARROWS AS INDICATED ON DRAWINGS. W/ BATTERY BACKUP. S SINGLE POLE TOGGLE SWITCH, 120/277V, 20A. S-10" AFF 3S / 4S THREE-WAY TOGGLE SWITCH/FOUR-WAY TOGGLE SNATCH, 120/277V, 20A. 3'-10" AFF MS MOTOR RATED SWITCH, AMPERAGE AS REQUIRED. VERIFY REQUIRED VOLTAGE AND # OF POLES W/ EQUIPMENT M S SINGLE POLE, THREE POSITION MOMENTARY CONTACT, 120/277 V, 20A. S-10" AFF D S DIMMER SWITCH. 120/277V, FLUOR/INC AND AMPERAGE AS REQUIRED. S-10" AFF S KEYED SWITCH. 120/277V, AMPERAGE AS REQUIRED. 3'-10" AFF ®/ ® OCCUPANCY SENSOR, 3'-10" AFF ® OCCUPANCY SENSOR, RELAY/POWER PACK, CONCEALED, ACCESSIBLE. © PHOTOCELL G / = PANEL, UGHTING OR POWER AS SPECIFIED IN PANEL SCHEDULE. ❑J FUSED DISCONNECT SPECIFY AMP/POLE Ep NON -FUSED DISCONNECT SPECIFY AMP/POLE MOTOR STARTER. NUMBER NEXT TO SYMBOL INDICATES SIZE, SEE SPECIFICATIONS FOR DESCRIPTION ® WHEN SHOWN WITHIN BOUNDARY OF EQUIPMENT PROVIDED AS PART OF THE EQUIPMENT. COMBINATION NONFUSIBLE DISCONNECT SWITCH/MAGNETIC MOTOR STARTER IN NEMA 1 ENCLOSURE, NUMBER NEXT TO SYMBOL INDICATES SIZE, SEE SPECIFICATIONS FOR DESCRIPTION EXHAUST FAN FURNISHED AND INSTALLED BY HVAC. REFER TO 4 MECHANICAL DWG'S FOR EXACT LOCATION AND ELECTRICAL REQUIREMENTS. Ip SINGLE RECEPTACLE 120/277V, AMPERAGE AS REQUIRED. 1'-6" AFF / DUPLEX/QUAD RECEPTACLE OUTLET, 120/277V, 20A. 1'-6" AFF qp / DUPLEX/QUAD RECEPTACLE OUTLET, 120/277V, 20A, 6" ABOVE COUNTER U.N.O. q? / DUPLEX/QUAD RECEPTACLE OUTLET, SPLIT WIRED WITH PERMANENT CONTROLLED MARKING, 120/277V, 20A. 1'-6" RECEPTACLE, FLOOR / CEILING FLUSH MOUNTED. 120/277V, 20A. 2-POLE SINGLE RECEPTACLE 24OV, AMPERAGE AS REQUIRED. 0k TVSS RECEPTACLE DUPLEX RECEPTACLE , 120V, 15A. EQUAL TO PANAMAX MODEL# MIW-SURGE. SPECIAL PURPOSE RECEPTACLE OUTLET, NEMA CONFIGURATION TO MATCH PLUG. "GF"=GROUND FAULT PROTECTED BY DEVICE OR BREAKER "WP"=WEATHER RATED, GF PROTECTED WITH WHILE IN USE COVER PLATE pp / Q / (21 JUNCTION BOX ABOVE GROUND CONDUIT - - - - - UNDERGROUND CONDUIT o/ CBB COMMUNICATIONS, TELEPHONE / COMPUTER BACKBOARD. Q HVAC CONTROLS, S-10" AFF U.N.O. MCI TIME CLOCK. LCt / LC2 LIGHTING CONTACTOR. MECHANICALLY OR ELECTRICALLY HELD AND NO. OF POLES AS INDICATED. RTS REMOTE TEST STATION U ELECTRICAL ABBREVIATIONS ALL ABBREVIATIONS SHOWN MAY NOT APPEAR IN DRAWINGS. 0 AT MAX MAXIMUM & AND MCB MAIN CIRCUIT BREAKER A AMPERE MCC MOTOR CONTROL CENTER AB ABOVE MCM 1000 CIRCULAR MILS AC ALTERNATING CURRENT MECH MECHANICAL A/C AIR CONDITIONING MH MANHOLE AFC ABOVE FINISH CEILING MIN MINIMUM AFF ABOVE FINISH FLOOR MISC MISCELLANEOUS AFG ABOVE FINISH GRADE MLO MAIN LUGS ONLY AIC AMPERE INTERRUPTING CAPACITY MFR MANUFACTURER ALUM ALUMINUM MTD MOUNTED APPROX APPROXIMyTE(LY) MTG MOUNTING ARCH ARCHITECT MTS MANUAL TRANSFER SWITCH ATS AUTOMATIC TRANSFER SWITCH N NEUTRAL AUX AUXILIARY NA NOT APPLICABLE AWG AMERICAN WIRE GAGE N.C. NORMALLY CLOSED BB BACKBOARD NEC NATIONAL ELECTRICAL CODE BKR BREAKER NEMA NATIONAL ELECTRICAL MANUFACTURER'S ASSO. BLDG BUILDING NFPA NATIONAL FIRE PROTECTION ASSOCIATION C CONDUIT N.I.C. NOT IN CONTRACT CAB CABINET NL NIGHT LIGHT CIR CIRCUIT N.O. NORMALLY OPEN CLG CEILING NO. OR # NUMBER CON CONTROL OD OUTSIDE DIAMETER CT CURRENT TRANSFORMER P POLE CTV CABLE TELEVISION PF POWER FACTOR CU COPPER PH OR 0 PHASE CWP COLD WATER PIPE PMS PAD MOUNTED SWITCH DB DIRECT BURIAL PML PAD MOUNTED TRANSFORMER DC DIRECT CURRENT DEG DEGREE PRI PRIMARY DETD DUAL ELEMENT TIME DELAY PROVIDE FURNISH AND INSTALL DIR DIRECTED PT POTENTIAL TRANSFORMER DISC DISCONNECT SWITCH PVC POLYVINYL CHLORIDE ON DOWN PW PART WINDING DPSL GARBAGE DISPOSAL REF REFERENCE DPST DOUBLE POLE - SINGLE THROW REQ REQUIRED DPDT DOUBLE POLE - DOUBLE THROW RLA RATED LOAD AMPERES DTXFMR DRY TYPE TRANSFORMER RM ROOM DW DISHWASHER RNC RIGID NONMETALUC CONDUIT EA EACH RNG ELECTRICAL RANGE EXH EXHAUST REF REFERIGERATOR EM EMERGENCY RT RAIN TIGHT EMT ELECTRICAL METALLIC TUBING SCCR SHORT CIRCUIT CURRENT RATING EP EXPLOSION PROOF SCH SCHEDULE EQUIP EQUIPMENT SO SOFT DRAWN ER EXISTING, REMOVE. SE SERVICE ENTRANCE EWC ELECTRIC WATER COOLER SEC SECONDARY EX EXISTING, REPLACE WITH NEW SH SHEET F FUSE SI INTERNATIONAL SYSTEM OF UNITS f FLUSH MTG SLD SINGLE LINE DIAGRAM FA FIRE ALARM SMR SURFACE METALLIC RACEWAY FIN FINISHED SN SOLID NEUTRAL FUR FLOOR SPECS SPECIFICATIONS FLA FULL LOAD AMPERES SPOT SINGLE POLE - DOUBLE THROW FMC FLEXIBLE METAL CONDUIT SPST SINGLE POLE - SINGLE THROW GA GAUGE STS STATIC TRANSFER SWITCH GALV GALVANIZED SW SWITCH GF GROUND FAULT INTERRUPTER SW BD SWITCH BOARD GRC GALVANIZED RIGID METAL CONDUIT SW GR SWITCHGEAR GND GROUND TB TERMINAL BACKBOARD HD HEAVY DUTY TELE TELEPHONE HH HANDHOLE TEMP TEMPERATURE HP HORSEPOWER TVSS TRANSIENT VOLTAGE SURGE SUPPRESSORS HV HIGH VOLTAGE TYP TYPICAL HVAC HEATING/VENTILATION/AIR CONDITIONII% UNDERWRITER'S LABORATORY HZ HERTZ (CYCLES PER SECOND) V VOLTAGE ID INSIDE DIAMETER VAC VOLTS ALTERNATING CURRENT IG ISOLATED GROUND VDC VOLTS DIRECT CURRENT IMC INTERMEDIATE METAL CONDUIT VENT VENTILATION J-BOX JUNCTION BOX W WIRE k KILO �1000) W/ WITH kCMIL KILO IRCULAR MILS WP WEATHERPROOF kV KILO VOLTS WT WATERTIGHT kVA KILO VOLT - AMPERES Z ZONE kW KILO WATTS FEET LFC UQUIDTIGHT FLEXIBLE CONDUIT INCHES LGT LIGHTING) LV LOW VOLTTAGE AUXILIARY LEGEND ALL SYMBOLS SHOWN MAY NOT APPEAR IN DRAWINGS. F❑ FIRE ALARM MANUAL PULL STATION, S-10" AFF j / M FIRE ALARM STROBE / HORN -STROBE, 7'-6" AFF 00/ Mc FIRE ALARM STROBE / HORN -STROBE. CEILING MOUNTED. © FIRE ALARM SMOKE DETECTOR, CEILING MOUNTED. ®y-- FIRE ALARM DUCT -MOUNTED SMOKE DETECTOR W/ SAMPLING TUBE. FIRE ALARM REMOTE TEST STATION, 3'-10" AFF ® FIRE ALARM HEAT DETECTOR. CEILING MOUNTED. ® FIRE ALARM AUXILIARY RELAY. M❑ MONITOR MODULE FOR AUXILIARY CONTROL Q / 0 FIRE ALARM FIRE SPRINKLER SYSTEM VALVE TAMPER SWITCH IS / FE-Sl FIRE ALARM FIRE SPRINKLER SYSTEM FLOW SWITCH FRAYI FIRE ALARM CONTROL PANEL. ® FIRE ALARM REMOTE PANEL. / d TELEPHONE/DATA OUTLET AND COVER PLATE. 18" AFF WITH 3/4" C. AAC/UNO COMBINATION DATA/TELEPHONE OUTLET AND COVER PLATE. 18" ACC WITH C 3/4"C TO ACC/UNO 04 DATA OUTLET AND COVER PLATE, MOUNTED ON COLUMN OR POWER POLE, Q FLOOR BOX, ROUND WITH DUPLEX RECEPTACLE, TELEPHONE AND DATA OUTLET. FLOOR BOX COVER SHALL BE BRASS WITH HINGED COVERS FOR DEVICES. ("2D DUAL DATA OUTLET, "4D"= QUAD DATA OUTLET) © CAN OUTLET SINGLE GANG BOX WITH 3/4" C TO AAF. VERIFY HEIGHT QS AUDIO SYSTEM SPEAKER. FURNISHED AND INSTALLED BY OTHERS. ❑A AUDIO VOLUME CONTROL. SINGLE GANG EMPTY OUTLET INSTALLED AT 46" AFF WITH 3/4"C TO AAF WITH DATA BUSHING. © CLOCK, WALL MOUNTED, PRIMEX WIRELESS ELECTRICAL DESIGNATIONS A02 FIXTURE NOTE TYPE 'A' FIXTURE (SEE FIXTURE SCHEDULE). CIRCUIT NO. 2 (TYP) ( n I FIXTURE NOTE TYPE 'A' FIXTURE (SEE FIXTURE SCHEDULE). CIRCUIT NO. 2 (TYP) A A RECPT NOTE WALL OUTLET WITH RECEPTACLE NOTED, CONNECT TO CIRCUIT NO. 2 (TYP) HOME RUN HOMERUN (TYP) TO PANEL 'PPA', CONNECT TO CIRCUIT PPA-5,6,7 NO.'S "5, 6, & 7" EX: 3#12 (PH), 1#12 (N) & 1#12 GND MULTI -CONDUCTOR RUN MULTI -CONDUCTOR RUN (TYP) EX: 3#12 (PH), 1#12 (N) & 1#12 GND WIRE DESIGNATION TIC INDICATES NUMBER OF CONDUCTORS, EX: 3#12 (PH), 1#12 (N) & 1#12 GND NOTES: 1. "NL" DESIGNATION REQUIRES FIXTURE TO BE CONFIGURED FOR ONE LAMP OPERATION AT ALL TIMES. 2. ALL CIRCUITS SHALL CONTAIN A GREEN EQUIPMENT GROUNDING CONDUCTOR. 3. EQUIPMENT GROUND CONDUCTOR SHALL BE AS FOLLOWS UNLESS OTHERWISE INDICATED: #12 AWG CIRCUIT - #12 GND #10 AWG CIRCUIT - #10 GND If 8 AWG CIRCUIT - #10 GND 4. UNLESS OTHERWISE INDICATED, CONDUIT SIZE SHALL BE 3/4" MIN. AND SHALL NOT EXCEED A FILL OF 40% MAXIMUM, SEE NEC. # OF CIRCUIT CONDUCTORS—J I#_ & i#_GND - _C �— SIZE OF CONDUIT SIZE OF CIRCUIT CONDUCTORS "AWG"SIZE OF GROUNDING CONDUCTOR "AWG" ELECTRICAL NOTES 1. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR OBTAINING AND PAYING ALL REQUIRED PERMITS AND INSPECTION CERTIFICATES. 2. ALL WORK SHALL COMPLY WITH FBC 2017, NEC 2014, STATE AND LOCAL CODES. VERIFY WITH AUTHORITY HAVING JURISDICTION AND COMPLY AS REQUIRED. 3. OMISSIONS OR MISDESCRIPTION OF DETAILS OF WORK WHICH ARE EVIDENTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS, OR WHICH ARE CUSTOMARILY PERFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMISSIONS AND DETAILS OF WORK, BUT THEY SHALL BE PERFORMED AS IF FULLY AND CORRECTLY SET FORTH & DESCRIBED. 4. EQUIPMENT, MATERIALS, AND INSTALLATION SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE. DEFECTS WHICH APPEAR DURING THIS PERIOD SHALL BE CORRECTED AT THE EXPENSE OF THE ELECTRICAL CONTRACTOR. 5. MATERIALS AND ALL COMPONENTS THEREOF SHALL BE NEW AND SHALL BE UL APPROVED WHERE A STANDARD HAS BEEN ESTABLISHED. COMPONENTS SHALL BE EQUAL TO THOSE SCHEDULED ON DRAWINGS. 6. ALL RACEWAY EXPOSED ON THE EXTERIOR SHALL BE RIGID GALVANIZED STEEL "RGS" OR "IMC". EMT SHALL NOT BE ACCEPTABLE. COORDINATE WITH ARCHITECT IF FINISH PAINTING SHALL BE REQUIRED. 7. VERIFY FIELD DIMENSIONS. COORDINATE WORK WITH OTHER TRADES TO AVOID INTERFERENCES. B. ALL EXIT AND EMERGENCY LIGHTS SHALL BE UNSWITCHED AND SHALL BE SERVED FROM THE SAME CIRCUIT AS THE GENERAL UGH11NG IN THE SAME AREA U.N.O. 9. ALL ELECTRICAL PANELS SHALL HAVE ENGRAVED LAMINATED (BLACK ON WHITE) LABELS IDENTIFYING THEM AS INDICATED ON DRAWINGS. 10. ENSURE THAT ALL PENETRATIONS OF FIRE WALLS AND DECKS ARE PROPERLY SEALED PER IBC, ANY APPLICABLE UL ASSEMBLIES, AND THE SPECIFICATIONS. 11. AU COMPONENTS USED IN PLENUM SPACES SHALL BE CONSTRUCTED OF NON-COMBUSTIBLE MATERIAL AND SHALL BE RATED FOR INSTALLATION IN PLENUM SPACES. 12. COLOR OF WIRING DEVICES AND PLATES SHALL BE AS SELECTED BY THE ARCHITECT. IF METAL DEVICE PLATES ARE USED, THEN DEVICE SHALL BE MOUNTED IN ORIENTATION WHERE GROUND PIN IS UP. 13. COORDINATE LAYOUT CAREFULLY WITH SYSTEMS FURNITURE AND MILLWORK SHOP DRAWINGS PRIOR TO ROUGHING IN POWER AND COMMUNICATIONS OUTLETS TO ENSURE PROPER ORIENTATION OF OUTLETS WITH COMPONENTS OF THESE SYSTEMS. 14. CONDUCTOR SIZES INDICATED ON THE DRAWINGS HAVE BEEN SELECTED TO PROVIDE FOR ACCEPTABLE VOLTAGE DROP. DO NOT REDUCE WIRE SIZES SHOWN WITHOUT CONSENT OF ENGINEER. 15. CONDUCTORS SHALL BE SINGLE CONDUCTOR COPPER, STRANDED FOR AWG #8 AND LARGER AND SOLID FOR AWG #10 AND SMALLER, WITH 600 VOLT THHN INSULATION. 16. ALL CONDUCTORS SHALL BE INSTALLED IN METALLIC CONDUIT. 17. THE LOCATION OF OUTLETS AND EQUIPMENT SHOWN ON THE DRAWINGS ARE APPROXIMATE AND THE OWNER SHALL HAVE THE RIGHT TO RELOCATE ANY OUTLETS OR FIXTURES BEFORE THEY ARE INSTALLED WITHOUT ANY ADDITIONAL COST. 18. TELECOM OUTLETS WHERE INSTALLED ADJACENT TO RECEPTACLE OUTLETS, SHALL HAVE UNIFORM SPACING BETWEEN RESPECTIVE DEVICES. E.C. SHALL UTILIZE MOUNTING PROVISIONS BETWEEN STUDS, IF REQUIRED, TO MAINTAIN THIS REQUIREMENT. 19. ALL POWER AND DATA TO BE ROUTED OVERHEAD. UNDER SLAB NOT ALLOWED. 1` 110 kn M_ 00 O� M M bNN cl Wrz o U wa � U o QI �i a z o w Q a F N ca w 0 F"I 4-4 C 4-J C laC Myy o W con W � O yn rwr� PROJECT NO: 20-xxx DRAWN BY: T.OWENS CHK'D BY: G.W. STEW/ SHEET NO: ELECTRICAL NOTES & LEGEND EO i A 6 c FURNISH AND INSTAL CONDUIT FROM COMMI BACKBOARD TO TELCO CONNECTION AT RIGH1 COORDINATE WITH LOC REPRESENTATIVE F LOCATION INSTALLATION. C( ROUTING AND BURIA WITH OTHER COORDINATE EXAM AND REQUIREMEN GRINDER PUMP PI ROUGH —IN. is u V I ELECTRICAL SITE PLAN ES1 SCALE: 1" _ 15'-0" HANDHOLE WITH GASKETED COVER AND TAMPERPROOF SCREWS BASE COVER WITH TAMPERPROOF SCREWS SLOPE 1" GROUT "' 11 6 11 4—#5 ® 6" TIES t 11 -,III FINAL GRADE I Li T_ -4 L ���� e \ 8—#5 VERT. 2.e #3 ® 12" TIES, TYP. f L-\ POLE BASE DETAIL ES1 SCALE: NONE in M M N N O� 75 �ti N U fs. O (s Cv P473 HU o W � W � �4 6 U ^ O W ® Q� LLI ® r�TT hr—I 7W �f PROJECT NO: 20-xxx DRAWN BY: T.OWENS CHK'D BY: G.W. STEWART SHEET NO: ELECTRICAL SITE PLAN ES 3 -. - -. ;`,. + . + ,- + -- --L----r+ .-_( -----r -- T ---' +. . �.._ It ..�.r._..._..�..-_ I+ I+ I+ I+ I I I I _ .-. ..___. 0.0 G.0 0.0 ,0-,.,-4?.0--... -; 0 8 ;- rOT p 0 rO.OT 0.01 0.0 0.0' 0.0 _I p.0i= ®0' =1-0' .O S2L.LO_ :_$$-_@ov' _ A 0 0 8® _® ® ® 0 0 0.0 +0.0 +0.0 0.0 0.0 +0.+0.0 0 I I I 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0. 0 0 I 1 t1 �-------- '0.0 0.0 +0.0 !' +0.0 +0.0 +0.0 '0.0 '0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 +0.0 +0.0 +0.0 +0.0/ 0.0 +0.0 `, +0.0 +0,1 +0.1 0.1 17+0.1 +0.0 +0.0 +0.0 +Q.O '0.0 +0.0 +0.0 +0 +0. % J' +0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 O.0-_--0.0- ._ _- 0.0� 6� 0, 0.1 0.1 0.1 0. 0.1 0.1 0.0 O.Q 0.0 0.0 O.Q A. 0.0 �- -- 0 25 ----- - - 1 + + + '0. - '0. + + + '0. + 1 +5 + + + _�+ + + + + + + + + + + + 0.0 0.0 0.0 0.0 0.0 0 0.0 0 0.0 0.0 O.O 0 0.0 0.1 0,1 0 0.3 0.3Q.3 0 3 0.1 d.1 0.2 0.3 0.3 .2 0.1 0.0 0.0 0.0 0.0 0.0 0. � b.0 --n.5 - 0.0 0.0 +0.0 0.0 +0.0 +0.0 +0.0 +0.0 0.0 +0.0 0.0 0.0 0.0 0.1 •25 + 4 +0.6 + II 1.0 +1.11 + .8 +0 0.1 2 +0.7 +0.7 Ii + .5 �.2 +0.0 0.0 +0.0 +0.0 +Q.O +0 .0 + + + + + H1+ + + + 5 + 1+ + + + +0 0 0 •0 �.6 .0 1.6 L9 2.2 3.1 2.1 0.4 - .2 -2�0.3 0. 1.3 1.3 0.8 •0.2 +0.1 0.0 0.0 0.0 0.0 I �. 0.0 '0.0 0.0 + + + + + + + 0.0 0.0 0.0 0.0 0.0 0.0 OA + + F 0.0 0.0 0 I t I 111111 + + + + + + + + + + + + + + + + '2. + + + + + ++' 0.0 OA 0.0 0.0 0.� 0.0 0.0 0.0 0.0 0.0 O.O , 0.0 0.6 1.3 2.3 2.0 81 3.8 ' 0. 0. 5 1.0 0 2.1 1. 0.1 0.1 0.0 0.0 0.0 . 1 0 0 --- -- - ---- - ° L--- - - - �A G 1 +0.0 '0.0 0.0 +0.0 +Q.) + 0 1 5�� - + ¢ +d.4 +1.2.8 3.4 +1.7 <D4 +0.2 +0.1 1 +0.1 +0.0 cS.' 0.0 !f + T6:t .7 5 3 0.0 --�- i AFG 0.0 0.0 0.0 (� 0.0 0. 0 • I 20.8 .6 �0.8 5+0.3 + 4 +1.4 3.5 0 +2.6 +0.7 +0.4 (`� +0.1 10.1 +0.0 1 0 0''i +Q.O + + + + I 11 + + + + + ---+ + + •5 + + + S + + + + y +I t 0A 0.0 0.0 1 0.0 0. 0 5 1 6 9 0.4 0.5 1.6 3.8 5. 5.24-0'h+0.8 0.3 0.2 0.1 0.0 0.0f,1 0.0 AFG 0.0 0.0 T0.0 ¢ 0.0 0. 0 ?7` - 1 k0.4.� 1.5 3.7 2.9 0.9 0.4 0.2 0.1 0.0 0.0 r 0.0 (I 0 + + + + + +I - +� �+ + + + + + l } + + + + rz +. w 0.0 0. 0 5 0.5 15. 5.9 i�.9 0.3 �i.4 1.4 3.2 4.0 2.0 /� 3 0.2 0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 i I tl -1 I + + + + + + + + + + + + + + + + �I+ 5 + 0.0 +0.0 0.0 0 0.0 0. 0 _ 20.5 .5 1 O.8 5 0.3 45 1.2 2.3 2.5 1. 0.1 :� 0.1 0.0 0.0 0.0 0.0 I i - -... - -- - -- u - I161-0" I - t-i' +0.0I - -- - -� - -�- -- - - - --� -- - -' U + + + fi + + + + F + + + + + 7 0.0 0.0 0.0 ' 0.0 �'-- ��!, 17.3 4.7 5 0. 0. 0. 16 1.6 0.2 0.1 0.1 0.0 0.0 0.0 0.0 b.0 0.0 0.; 1 !I 0. 1. .4 i. _+ 9 1 �6.5 - �i0 8 2- t2+G$ 4 111 0 r- 1 9.3 3.8 h 10 s 2 JJO.3 \ 0.6 (Q.9' 0.9 6 2 1 0.0 0.0 0.0 0.0 0.0 0.0 �0 0 G I� -1- -AF I------- q it + + + i ++� + + + + + + +� + + �) - 5 0.0 0.0 --O�1 I •2 5 1.1 - 16.7 9.3 10.8 T10.0 8.8 +8.8 9.5 1 0r 9.81 7.3 5.1 3.6 4. 2.3 0. +0.2 +0.4 0 4!, 0' 4 +0 +0.1/ +0.0 +0.0 +Q.O +0.0 +0.0 +0 0Q 1 -- ---- -- � + + + 1 ++) + I+ + + + + + + + 1 + + + + +•25 + 1 + + + + + + r - 5 2.2 2.6 2.8 3.5 3.3 3.5 3.6 3.2 3. 2.9 2.6 2.2 1.9 1.6- o.o 0.0 1 0. Q. (iI. or- , +0.2 0.2 r o.2 0.2 1 0.0 0.0 0.0 0.0 0.0 0 �I) 10.0 +0.0 +o.0 0. 8 1 0 +1.0 +1.0 +1.1 .0�'�1..0 - .9 - +0.9 .9 +0.8 '-0.7 +0.7 0.7 + . •5 +0.4 (o. 2 +0.1 +0.1 +0.1 0.1 / 0.1 I �0.1 , +0.0 ' - +0.0 ' - l � 5 --------1 -- -� 0 ,�J� _ � y + + + + + 9 + + + + t + + + + + + + + + "I' + + + + + + + + 0.1 0. t5 t ."..---.-. - 1.2 1.3 1.2 1. _ 0.6 s - 0 40.4 Q.4 0.3 0.3 +0.3 0.3 -A:2----.-..-0.2 _ 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 _ 0.0 +0.0 0.0 1 Ily 0.1 -- --8 _ z 5 ___ 2.9 2.6 2.3 1.5 1.1 0LL8 ___0..8---- 0.7 0.5 #Q:5 0.4 0.3 0.7 0.7 0.8 0.2 0:i1 0.1 0.0 0.0 0.0 0.0 )0. il" 0.0 + o + j+ + + + -- + -_ + + + + + + + + + + + + + + + + + + 0.0 0.0 0.0 11 5 1 �' 1.9 3,1 4.6 5. 4.4 3.4--�-.. 2 3 4 6 ____ 1.3 1.3 1.6 2.0 2.3 2.4 2.4 2.1 1.8 1.3 0.9 .5 .3 0.1p•1 0.1 0.0 0.0 0.0 0.0 0.0 + +0.0 + + + + + 0,0 0.0 0.1 LO.� J * 4.1 2.7 2.0 , 1.5 + + + + + -0 + + =� + + '0.0 0.0 0.0 0.0 0.� 0.0 .1 25fi 0. 1.9 2.1 1B ' 1� 1.2 .5 2.0 -- 2.8 4.1 4.9 - .0 4.4 3.1 -� ---- +2 2.0 +0.1 +o�25 +0. +0.0 0.0 +0.0 +0.0 +0.0 0.0 I .1 + 5 0.3 + 1 +0.0 +0.0 +0.0 +0.0 +0.0 +0.0 I� UGEU UGF-- UG --UGE m "_-__..........--� n - I GE- •_ UCF-" Gfi � E .- 0.0 0.0 0.0 0. 0.0 0.1 ' 1 +0.1 0.3 0.6 0.7 0. -- E - f p 7 UGE ..UGE-- +dci - UGE- 4-6 _- p Lam: t -_ U+ 4 'u4t-- . X �- __ ., - - - - - _ _ J UEk -�'- 4 0 0.8 0 9_ _.__+D_8-- + 211�2 _ _ UGE-Lf E GE .. . 0" UTI iIy EASE__�_--- -- n --- 0.0 0.0 0. OA 0.0:O.�F - ° 0 jr 0.2 0.1 0.. 0 1 0.2 0.2 0.2 5 0. 0.6 0.7 0.2 0.1 1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 I 0.0 .25 -I- -- - -... - ---- - - -- -- .. _ - -. 1- +0 O + + + -_+ +---- -- --- + -- + 25 + + + + + + + + + + + + + + + + + + + + + + Ell + 0.0__.- OA-----0.0- 0.0 0.0 0.1 11 0.2 0.2 0. 0.2 1 0.1 0.0 0.0 0.1 .11 0.1 .3 0.4 ��.__._- 5------0;1----�,}------- 0.6- 09--- 0.0 Oco 0=0----00--0.0 0.0 0.0 0.0 0. --------- - ------ - - - 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 :'I 0.1 0.0 0.0 0.0 0.0 0.1 -__ .L 0 0.0 0.0 0.0 0.0/ 0.0 0. _ ---- - - - _ - - - - - ' - 0 - 0- - - - .0 +0.0 +0.0 +0.0 +0.0 - +Q.O T0.0 +0.0 +0.0 - +0.1 . _ +0.1- +0.1 +0.0 +0.0 +0.0 + .0 +0.0 +0.0 +0.1 0 1 +0.1 +0.1 0.1 +0.1 +0.0 .-li/t^.... 0 - - 0 0 0. �0I+ .0 0 �.._ I \ jI 2 6 D V QSITEPHOTOMETRIC PLAN SCALE: 1 " = 1 S'-0" 8 9 15 �V Statistics Description Symbol Avg Max Min Max/Min Avg/Min Site I + 10,8fc 120.8fc 10.Ofc I N/A I N/A Schedule --i Label QTY Catalog Number Description Lamp Number Lumens LLF Wattage Polar Plot Lamps per Lamp 4 LHSWP-1C4T3F LED Heat Sink Small Wall Pack LED COOL WHITE LUXEON M 8 431 0.92 35.2 1 C' (1400mA) 4 CRT1603151229-001A Multifunction Fixture 5000K w/ Type 3 LED 1 11975 0,92 129 H type 3, Model: HN15C- Optics 20 3 CRT1603151229-001A Multifunction Fixture 5000K wl Type 3 Optics ILED 1 11975 0,92 129 S type 3, Model: HN15C- HN15C-120-50K-DRIVER WITH FIXED MOUNT 120 SQUARE POLE OR TENON 6 r^ �n A CX �00 � err od � �Cis Nr Orb �eNa „ W U ON Ow a 0 �x V C Yell �= R GA d C L � zI I 1 � of C I E...r 0 O V O M � W � P4 z 9 �t J O o W � PROJECT N0: 20-xxx DRAWN BY_-T.OWEN CHK'D BY: G.W. STE SHEET NO: SITE PHOTOMETF PLAN ES2 r" J 8 to A IJ cl — (cam 01 RIGID PIPE SLE THROUGH BUILDING I PHONE LINE PENETRAT SEAL ALL PENETRATI 1" CONDUIT EMS PANEL BEL CAi f CABLE TRAY AND CONDUIT KEY NOTES: O ELECTRICAL DMARC AND EMS PANELS IN RECEIVING AREA. CONDUIT �1: PROVIDE 1-1/2" CONDUIT TO CABLE TRAY. O VOICE AND DATA PORT. CONDUIT #2: PROVIDE 1" CONDUIT FROM VOICE/DATA PORT TO CABLE TRAY. O CONDUIT #3: 1" CONDUIT FROM SALES REGISTER TO a CABLE TRAY. 2 �3 4 5 � I i 1 ,.1 I Ill\111111 T[^ YIIPII rl Plr P1YrP 1tlAl1 f�llll l I I PUSHBUTTON KEY' NOTES (THIS SHEET ONLY) CABLE TRAY HUNG WITH AIRCRAFT CABLE, ADD UNISTRUT TO PURLINS AS REQUIRED FOR HANGING. WHERE CABLE TRAY IS INDICATED IN PLANS BETWEEN PURLINS, CONTRACTOR SHALL INSTALL STRUT BETWEEN EACH JOIST FOR EACH POINT OF ATTACHMENT. N POWER & AUXILIARY PLAN E1 SCALE: 3/16" = 1'-0" 1Q WEATHER PROOF RECEPTACLE MOUNTED ON ROOF FOR ® CONTRACTOR SHALL VERIFY FINAL LOCATION OF ICE HVAC MAINTENANCE PURPOSES. MACHINE WITH DOLLAR GENERAL PRIOR TO ROUGH -IN. 2Q LOW VOLTAGE VENDOR TO PROVIDE AND INSTALL ONE (1) LOCATION OF OFFICE HUB BELOW. BUNDLE ALL WIRE AND 24 GA. 4 TWISTED -PAIR, CAT 5 DATA CABLE WITH RUN TO CABLE TRAY. MODULAR COMBO RJ-11/RJ-45 JACK AT MANAGERS OFFICE. CABLE TO BE RUN FROM JACK TO DATA HUB Q ALL CONDUIT TO RTU SHALL BE CONCEALED INSIDE CURB. LOCATION WITH 6'-0" LEFT COILED ABOVE CEILING FOR DO NOT ROUTE THRU EXTERIOR. INSTALLATION TO DATA HUB. A RJ-45 MALE FITTING SHOULD BE CRIMPED ON THIS END. DOLLAR GENERAL 7U WEATHER PROOF RECEPTACLE FOR IRRIGATION SYSTEM. STORE OPENING TEAM WILL MAKE FINAL CONNECTION INTO COORDINATE EXACT LOCATION PRIOR TO ROUGH -IN. DATA HUB. 30 STAND ALONE DUCT SMOKE DETECTOR, FAN SHUTDOWN ® ENDCAP COOLER/FREEZER AND DISPLAY LIGHTING AS AND HORN/STROBE SYSTEMI NEEDED TO BE HARDWIRED THROUGH WHITE SO CORD. GC TO LEAVE BOTTOM HANGING AT 80"AFF. CORD ANCHORED COMPONENTS SHALL BE EQUAL TO E➢WARDS SIGNAL TO PURLINS ABOVE. COORDINATE LOCATION WITH FINAL DG SD SERIES SYSTEM AND EG1 SERIES HORN/STROBE, FIXTURE PLAN. FURNISH AND INSTALL ALL COMPONENTS AS REQUIRED FOR AUTOMATIC SHUTDOWN IN EVENT OF FIRE. FAN Q USE HILTI FIRE STOP CABLE COLLAR CFS-CC. QUANTITY SHUTDOWN SHALL INITIATE SHUTDOWN OF ALL AIR AS REQUIRED. HANDLING UNITS, 10 NOT USED. SAMPLING TUBES AND CEINTROL WIRING AT AHU SHALL BE PERFORMED BY MECHI CONTRACTOR, COORDINATE EXACT LOCATION OF TEST SWITCH AND HORN/STROBE WITH ARCHITECT :ATE ALL JDUIT TO OFFICE THIS WALL. v yy PROVIDE 208V, 1 PHASE CONNECTION TO A J-BOX AT 100" AFF WITH (3)#12 CU. & #12 GROUND IN 3/4"C. REFRIGERATION CONTRACTOR TO PROVIDE AND INSTALL 3OA/2NF DISCONNECT SWITCH AND WIRE FROM DISCONNECT SWITCH TO EQUIPMENT CONNECTIONS. INSTALL JUNCTION BOX 11" FROM THE RIGHT SIDE OF EACH UNIT. COORDINATE EXACT LOCATION WITH REFRIGERATION PRIOR TO ROUGH -IN. 12 PROVIDE 208V, 1 PHASE CONNECTION TO A J-BOX AT 100" AFF WITH (3)#8 CU. & #10 GROUND IN 1"C. REFRIGERATION CONTRACTOR TO PROVIDE AND INSTALL 6OA/2NF DISCONNECT SWITCH AND WIRE FROM DISCONNECT SWITCH TO EQUIPMENT CONNECTIONS. INSTALL JUNCTION BOX 11" FROM THE RIGHT SIDE OF EACH UNIT. COORDINATE EXACT LOCATION WITH REFRIGERATION PRIOR TO ROUGH -IN. 13 PROVIDE 208V, 1 PHASE CONNECTION TO A J-BOX AT 100" AFF WITH (3)#10 CU. & #10 GROUND IN 3/4"C. REFRIGERATION CONTRACTOR TO PROVIDE AND INSTALL 3OA/2NF DISCONNECT SWITCH AND WIRE FROM DISCONNECT SWITCH TO EQUIPMENT CONNECTIONSIN STALL JUNCTION BOX 11" FROM THE RIGHT SIDE OF EACH UNIT. COORDINATE EXACT LOCATION WITH REFRIGERATION PRIOR TO ROUGH -IN. M CIS N N N � N U ON O4+ a: C-4 U o ruJ U p1��p�1 � O 1� � s✓ w a E--I Fw9 0 M--I J d 04 0 w I PROJECT NO: 20—xxx DRAWN BY: T.OWENS CHKD BY: G.W. STEWART SITEET NO: POWER & AUXILIARY PLAN E1 r A i; 0 N CEILING MOUNTED OCCUPANCY SENSOR AT STANDARD RANGE. (TYPICAL OF 2) A B-1 NL R CEIVING RECEIVING AREA LIGHTS SHALL BE MOUNTED AT ` 10'-6" TO 12' A.F.F. AND ..__. SPACED EVENLY BETWEEN FRONT AN{D REAR WALL A n �2 ALL CONDUITS THRU FIRE RATED WALL SHALL BE ROUTED,THRU FIRESTOP CABLE COLLAR CFC—CC, UL 1479. SEE DETAIL 6/E3. n A / A B-13 EMERGENCY/EXIT SIGNS AND LIGHTS: INSTALL EMERGENCY LIGHTS AND EXIT SIGNS (CENTERED AT 10'-6" A.F.F. TO BE ABOVE FIXTURES & MERCHANDISE) THROUGHOUT THE BUILDING IN COMPLIANCE WITH ALL APPLICABLE CODES. i I ; A / i A N 1 LIGHTING PLAN E2 SCALE:3/16"=1'-0" I1 A B-9 VA E X g E t MIENS 104 A I A A OCCUPANCY SENSOR— LEVITON MODEL # B 12 - EZ—FIND ODS-10—IDW -.-.-.-� (TYPICAL) AI A �w B °o E I WOMENS 105 A I -- A A os I i SI ARBI CKS DNA K I� CPOLERS SIiA(K A-28 AI I � F i A A A J D � F—' Ao NL ' A A-28 I »„I _.. A A , OFFICE & E A BREAKROOM LIGHTS MOUNTED � 11 —0" A.F.F. so B 12 OFFICE w ° 101 )A I^ DPP — —a A 2 A A BREAK ROOM B-15 B-11 1'X4' LIGHT FIXTURES HUNG WITH AIRCRAFT CABLE, ADD UNISTRUT TO PURLINS AS REQUIRED FOR HANGING. WHERE LIGHTING FIXTURES ARE INDICATED IN PLANS BETWEEN PURLINS, CONTRACTOR SHALL INSTALL STRUT BETWEEN EACH JOIST FOR EACH POINT OF ATTACHMENT. KEY NOTES (THIS SHEET ONLY) 1O OCCUPANCY SENSOR POWER PACK FOR LIGHITNG CONTROL. LEVITON MODEL #OPP20 OR APPROVED EQUAL. Q CEILING MOUNTED OCCUPANCY SENSOR FOR RECEPTACLE AND LIGHTING CONTROLS. LEVITON MODEL #OSC—M OR APPROVED EQUAL. SEE DETAIL 5/E3. N ; 00 zl~0� 3 Q C7) ot " " �kr) u v a c�rxC rn con 6-1 O 61 i. O 4 aI i i H O � ® � C a� IIiI' 00 O W w � O "I w PROJECT N0: 2Q-xxx DRAWN BY: T.OWENS CHK'DBY: G.W.STEWAF SHEET NO: LIGHTING PLAN E2 3/4" PLYWOOD 8'-0" WIDE X 5'-5" HIGH, FIRE RATED, NO VOIDS, PAINTED WHITE UNLESS CODE DICTATES OTHERWISE. T-1„ 1'-81, 5' 1' 8" 5" 9 1 2" N = N PANEL [LABEL A/6S N DMARC (� �II 4 8 FLOOR LINE DUPLEX RECEPTACLE I DEDICATE CIRCUIT TELEPHONE CONDUIT STUB THROUGH WALL. SEE NOTES. NOTES. 1. EXTERIOR EXPOSED PHONE LINES TO BE INSTALLED IN RIGID CONDUIT. PROVIDE EMERSON 3/4" x 5'. METALLIC GABLE U-GUARD #755, OR EQUAL. 2. PROVIDE 1-1/2" EMT CONDUIT TO ACT AS ACCESS SLEEVE TO ALLOW PHONE COMPANY TO TERMINATE AT DMARC. CONTRACTOR TO PROVIDE AND INSTALL PHONE WIRING & RJ-11 PHONE JACK FOR COMPLETED WORKING SYSTEM PRIOR TO PHONE COMPANY FINAL HOOK-UP. ELECTRICAL PANEL ELEVATION E3 SCALE: N.T.S. 186" MODULAR POWER POLE FOR S200-B COUNTER INSTALL (4) IG CIRCUITS 20A 120VAC, (4) NORMAL CIRCUITS 20A 120VAC 12'-6" 13'-6" 14'-6" 15'-6" VERSIONS, ALL WITH 4" 182" DATA ACCESS AT BOTTOM 3 CH POLE POWDER COAT BLACK 1 DS-IG D5-IG 1DT4 10" I 1D4 8" 6" 1" 4" BLOCKER INSET 2" '/" HOLE THIRD ALL 1" UP WITH GROMMET FOR DATA CABLE DATA COVER AND ADD -ON DATA CHANNEL STOP 4" SHORT OF BOTTOM FOR DATA PULL AGCESS NO SHARP EDGES 4" PHONE LINE #1 LABEL AS "PHONE" RJ-11 JACK: 1 - REGISTER w EXTRA WIRES TO BE WRAPPED AND TAPED AROUND CABLE LU ALL WIRES ARE CAT 5, 4-PAIR m USE SEPARATE RJ-11 JACKS FOR EACH CONNECTION RJ-11 JACK BLUE w BLUE & z Z z WHITE J 3 PHONE WIRING FOR REGISTER E3 SCALE: N.T.S. REGISTER POWER POLE SCALE: N.T.S. 186" z 1 /a" --{ POWER 3 1 /2 DATA 1 DATA 2 POWER POLE PROFILE TRIM KIT 3 3/4" 1" 2„ T 1/8" 01 /4" POWER POLE STRAP RED=HOT- CIRCUIT 2 BLACK=HOT- CIRCUIT 1 — WHITE=NEUTRAL GREEN=GROUND R 747DGS023R B C WHITE=1 GREEN= *NOTE: BEFORE ORDERING AND INSTALLATION OF ELECTRICAL COMPONENTS FOR REGISTERS, CONSULT FINAL FIXTURE PLAN FOR NUMBER AND LOCATION. MAXIMUM CIRCUITS FOR REGISTERS - CIRCUITS AT MAIN REGISTER - (9) 110V CIRCUITS AT ISLAND REGISTER - (3) 110V ENLARGED POWER & AUXILIARY PLAN GREEN/YELLOW=ISOLATED RED=HOT - GROUND CIRCUIT 2 BLACK=HOT - CIRCUIT 1 WHITE=NEUTRAL REEN=SHIELD GROUND 0 k, 747DGS023B GREEN=SHIELD GROUND WHITE=NEUTRAL GREEN/YELLOW=ISOLATED GROUND BLACK=HOT RED=HOT- - CIRCUIT 1 CIRCUIT 2 REGISTER ELECTRICAL COMPONENTS Qty. D&P Part No. Power Pole Description National Account Provider 1 747DGS023B Dual circuit power kit with isolated ground D & P 1 747DGS023R Dual circuit power kit D & P 1 747DGSO44-126B 12' 2CH Regular Pole W/2-C & 1-D Connector DRW 1 747DGS032A 10' Cable Kit (Set of 4 whips) E3 SCALE: 1 /4" = V-0" KEY NOTES (THIS SHEET ONLY) LOW VOLTAGE VENDOR TO PROVIDE AND INSTALL ONE (1) 24 GA. 4 TWISTED —PAIR, CAT 5 DATA CABLE WITH MODULAR COMBO RJ-11/RJ-45 JACK AT MANAGERS OFFICE. CABLE TO BE RUN FROM JACK TO DATA HUB LOCATION WITH 6'-0" LEFT COILED ABOVE CEILING FOR INSTALLATION TO DATA HUB. A RJ-45 MALE FITTING SHOULD BE CRIMPED ON THIS END. DOLLAR GENERAL STORE OPENING TEAM WILL MAKE FINAL CONNECTION INTO DATA HUB. Q LOCATION OF OFFICE HUB BELOW. BUNDLE ALL WIRE AND RUN TO CABLE TRAY. VOICE AND DATA PORT. CONDUIT #2: PROVIDE 1" CONDUIT FROM VOICE/DATA PORT TO CABLE TRAY. OCCUPANCY SENSOR POWER PACK FOR RECEPTACLE CONTROL. LEVITON MODEL #OPP20 OR APPROVED EQUAL. CEILING MOUNTED OCCUPANCY SENSOR FOR RECEPTACLE AND LIGHTING CONTROLS. LEVITON MODEL #OSC—M OR APPROVED EQUAL. REGISTER ELECTRICAL DETAIL E3 SCALE: N.T.S. 1 D5-IG GREEN 1 D5-IG GREEN 1D4 BROWN 1D4 BROWN Firestop cable collar CFS-CC Applications * Single and bundled cables in floors and walls * New and existing cable installations IN Conduits, coaxial cables, conduit bundles Advantages Fast and easy solution for dry walls * Problem solver for 100%fill of openings up to 108mm in diameter . No chisel work in massive walls necessary * Up seal doses annular gaps 09 Zero separation to next. firestop cattle collar • Re -penetrable to allow increase in future cable capacity • Pre -formed firestop material does not, expire; eliminating shelf -life concerns • Immediately functional after installation IN Low VOC content and no CFCs or H6FCs.. CE Ordering Technical data CFS CC Temperature resistance range -15-60'C Ordering derbi-ndion Packaging content Mlnrmgmordarquantity Item number Firestop cable collar CFS-CC 2 PC 2 PC 02079667 Firestop filler mastic CFS-FIL Applications N For use with Hiitl firestop cable collar CFS-CC (gap filling) Advantages N Can be used with Hifti dispenser CFS-DISP Ordering Ordering decgnafoon Pacraging content Minimum order qu ri ity form number Firestop filler mastic CFS-FIL 310 ml 1 PC 02052899 Firestop putty bandage CFS-P BA IC, { iillil .d^. a3at t E Applications �r h • For use with Hiiti firestop cable collar CFS-GC Il.11l • For specific cable configurations, to achieve El 120 Advantages Easy tocut Self-adhesive Ordering ordering declaration Packaging content. Ivinmum order el item number Firestop putty bandage CFS-PBA 5 m 1 PC 02062876 page Him Firestop cable Collar CPS -CC I issue 10/2013 GROUPED CONDUIT THRU FIRE RATED WALL DETAIL SCALE: NONE O d- 00 �M CJ1 cC OMC M N aj '—' bill N O �I rn N U �N O+ G Cg Ix O } m F�1 . y ` IZ O v � a O I1 ryWh ICI I �I Z M I o W if PROJECT NO: 20-xxx DRAWN BY: T.OWENS CHK'D BY: G.W. STEW SETEET NO: ELECTRICAL ti DETAILS E3 1. 1 TO XFMR NEUTRAL (XO) TO COUNTERPOISE PANEL A VOLTAGE (L-N): 120 ENCLOSURE TYPE: NEMA 1 VOLTAGE (L-L): 208 OUNTING: SURFACE RASES, WARES: 3 � 4 W AIC RATING (A): 22000 (VERIFY AVAILABLE SHORT CIRCUIT PRIOR TO ROUGH -IN) MINIMUM BUS CAPACITY (A): 400 A 0TES: • DENOTES BREAKER LOCK VAIN O.C. DEVICE (A): 400 A CKT NO DESCRIPTION TRIP AMPS POLE PHASE LOADS (VA) POLE TRIP AMPS DESCRIPTION CKT NO A B C 1.3.5 TU-1 TU-i 60 60 3 3 1 5764 500 5764 500 1 1 20 AUTOMATIC DOOR 2 1,3,5 20 TBB 4 1.3.5 TU-1 TU-2 TU-2 60 60 60 3 3 3 1 5764 400 5764 1500 5764 0 1 1 1 20 ENERGY MANAGMENT 6 7,9,19 20 OUTDOOR HVAC RECEPT 8 7.9.11 20 OUTDOOR DRINK VENDING 10 7,9,11 TU-2 TERFACE EQUIP. CTV EQUIP. 60 20 20 3 1 1 500 500 1000 1800 5764 750 1 1 1 20 BUZZER 12 13 20 VSAT SATA HUB EQUIP. 14 15 20 EWH-1 16 17 EWH-2 20 1 1800 400 1 20 ICE CREAM POWER COOLER 18 19 RINKING FOUNTAIN 20 1 350 400 1 20 GATORADE COOLER 20 21 OUTDOOR ICE MERCHANDISER 20 1 1500 400 1 20 DRINK COOLER 22 23 RIGATION SYSTEM 20 1 500 400 1 20 SODA COOLER 24 25 PARE IANEL 20 1 0 400 1 20 SODA COOLER 26 27 PARE 20 1 0 2248 1 20 2 DOOR DRINK COOLER 28 29 PARE PARE 20 20 1 1 0 1300 0 0 1 2 20 PARE 30 31 15 COOLER 32,34 33,35 GRINDER PUMP (VERIFY BKR SIZE) 30 2 1800 1300 2 15 COOLER 32,34 33,35 GRINDER PUMP (VERIFY BKR SIZE) 30 2 1800 1300 2 15 COOLER 36,38 37,39.41ANEL B 200 3 16299 1300 2 15 COOLER 36,38 37,39.41 8 200 3 16324 1300. 2 15 COOLER 40,42 37,39,41 PANEL B 1 200 1 3 17510 1300 2 15 COOLER 40,42 Receptacles (0 - 10 KVA) Receptacles (Over 10 KVA) Cooling and Heating Equipment Heating Lighting Kitchen Equipment - Non -Dwelling Unit Lighting - Exterior Motors Motors (Largest) TOTAL;- LOAD (AMPS): CONNECTED LOAD PHASE TOTALS (VA) 33477 1 41200 1 37288 CONNECTED LOAD (KVA) DEMAND FACTOR DEMAND LOAD (KVA) 10.0 1.00 10.0 17.5 0.50 8.8 34.6 1.00 34.6 0.5 1.00 0.5 3.6 1.00 3.6 5.2 1.25 6.5 34.8 0.65 22.6 2.0 1.25 2.5 0.1 1.00 0.1 3.6 1.25 4.5 112.0 93.7 310.8 260.2 DEMAND LOAD 93.7KVA SPARE CAPACITY 50.4KVA SPARE CAPACITY 139.8 AMPS SPARE CAPACITY 35 % PHASE BALANCE A TO B 81 % B TO C 91 % C TO A 90 % ___7 NEUTRAL BUS GROUND BUS BOND TO ENCLOSURE 0 TO COLD WATER PIPE 0 TO BUILDING STEEL CONCRETE ENCASED ELECTRODE (DELETE WHERE NOT APPLICABLE) 1� #2/0 MAIN BONDING JUMPER O#2/0 GROUNDING ELECTRODE BONDING JUMPER CONNECTION SAME SIZE AS PHASE CONDUCTOR OSUPPLEMENTAL GROUNDING ELECTRODE BONDING JUMPER SIZED AT #6 AWG (SIZE PER NEC 250.66 IF WATER PIPE AND BLDG. STEEL NOT AVAILABLE) OSIZE PER NEC 250.66 BUT NO LARGER THAN #4 THHN Q MAIN SERVICE GROUNDING SCALE: NONE ALTERNATE METHOD OVERHEAD SERVICE ENTRANCE - WHERE U/G SERVICE NOT ABLE TO BE INSTALLED OR COORDINATED WITH UTILITY. TWO PARALLEL RUNS OF: (4) #250KCMIL (AL), 2-1/2"C, CT CABINET OR - DEMAND TYPE FEED-THRU METER PER UTILITY COMPANY REQUIREMENTS PRIMARY METHOD UNDERGROUND SERVICE ENTRANCE PER UTILITY AND SITE -SPECIFIC CONDITIONS WIRING TO BE SIZED PER LOCAL CODE REQUIREMENT TWO PARALLEL RUNS OF: (4) #250KCMIL (AL), 2-1/2"C, N E4 TWO PARALLEL RUNS OF: ,4) #250KCMIL (AL), 2-1/2"C, DISC. 208V 400AF 30,4W N3R PANEL A 208/120V 400A, 30 MLO NEMA 1 42CKT L_--_-___-L_-_J EXTERIOR 4) #3/0 AWG, & 1) #6 GND, 2"C PANEL B 208/120V 200A, 30 MLO NEMA 1 42CKT -TWO PARALLEL RUNS OF: (4) #250KCMIL (AL), (1) #3/0 GND (AL), 3"C Q ELECTRICAL SERVICE RISER SCALE: NONE PANEL B VOLTAGE (L-N): 120 ENCLOSURE TYPE: NEMA 1 VOLTAGE (L-L): 208 OUNTING: SURFACE RASES, WIRES: 3 0 4 W AIC RATING (A): 10000 MINIMUM BUS CAPACITY (A): 200 ANOTES: ---- VAIN O.C. DEVICE (A): 200 A CKT NO DESCRIPTION TRIP AMPS POLE PHASE LOADS (VA) TRIP AMPS DESCRIPTION CKT NO A B POLE C 1 NIGHT LIGHTS (EMS) 20 1 395 200 1 20 SECURECEPT 2 3 RECEIVING LIGHTS (EMS) 20 1 90 1000 1 20 FICRITY OFE RECEPT 4 5 0% SALES LIGHTS (EMS) 20 1 240 0 1 20 PARE 6 7 0% SALES LIGHTS (EMS) 20 1 270 600 1 20 REAKROOM RECEPT g 9 0% SALES LIGHTS (EMS) 20 1 270 186 1 20 PARE 10 11 FOX SALES LIGHTS (EMS) 20 1 300 370 1 20 BEAK, OFFICE & RESTROOM LIGHTS 12 13 % SALES LIGHTS (EMS) 20 1 210 1200 1 20 POWER TERMINAL BROWN 14 15 % SALES LIGHTS (EMS) 20 1 570 1200 1 20 POWER TERMINAL BROWN 16 17 ARE 20 1 0 1200 1 20 POWER TERMINAL GREEN (IG) 18 19 TERIOR LIGHTS (EMS) [PYLON 20 1 324 1200 1 20 POWER TERMINAL GREEN (IG) 20 21 TERIOR LIGHTS (EMS) 20 1 108 1200 9 20 POWER TERMINAL GREEN (IG) 22 23 UILDING SIGN (EMS) 20 1 0 1200 1 20 POWER TERMINAL GREEN (IG) 24 25 SIGN (EMS) 20 1 1800 1200 1 20 POWER TERMINAL BROWN 26 27,29 27,29 ITE LIGHTING (EMS) SITE LIGHTING (EMS) 30 30 2 2 1000 1200 1000 1000 1 1 20 20 POWER TERMINAL BROWN 28 2 DOOR COOLER 30 31,33 2 DOOR FREEZER 20 2 1 1300 2 15 COOLER 32.34 31,33 2 DOOR FREEZER 20 2 1800 1300 2 15 COOLER 32,34 35.37 FREEZER 25 2 2800 3200 2 40 FREEZER 36,38 35,37 FREEZER 25 2 1 2600 1 3200 1 2 40 FREEZER 36,38 39.41 FREEZER 40 2 3200 1 3200 2 40 FREEZER 40.42 39.41 FREEZER 40 2 3200 1 3200 2 40 FREEZER 40,42 Receptacles (0 - 10 KVA) Receptacles (Over 10 KVA) Lighting Kitchen Equipment - Non -Dwelling Unit Lighting - Exterior Motors Motors (Largest) TOTAL: LOAD (AMPS): CONNECTED LOAD PHASE TOTALS (VA) 16299 163241 17510 CONNECTED LOAD (KVA) DEMAND FACTOR DEMAND LOAD (KVA) 10.0 1.00 10.0 6.0 0.50 3.0 5.0 1.25 6.2 27.0 0.70 18.9 2.0 1.25 2.5 0.1 1.00 0.1 0.1 1.25 0.1 50.1 40.8 139.2 113.2 DEMAND LOAD 40.8KVA SPARE CAPACITY 31.3 KVA SPARE CAPACITY 86.8 AMPS SPARE CAPACITY 43 % PHASE BALANCE A TO B 100 % B TO C 93% C TO A 93% LEDS LIGHT FIXTURE SCHEDULE SYMBOL TYPE MANF. PART # DESCRIPTION W 4' LED FIXTURE o A ETI 54573161 AERIAL MOUNT INCLUDES 33 (2) 8 FT CABLES ® Al ETI 54573161 4' LED FIXTURE 33 SURFACE MOUNT I� B ETI 54260161 2' LED FIXTURE 20 SURFACE MOUNT D ETI 55502201 LED EXIT SIGN / EMERGENCY LIGHT COMBO WITH (2) HEADS LED EMERGENCY LIGHT E ETI 55501101 WITH (2) HEADS LED EGRESS EMERGENCY F ETI 55503101 LIGHT WITH (2) HEADS C�] G SEE SHEET ES2 LED WALL PACK LED AREA LIGHT ON WALL 4 H SEE SHEET ES2 MOUNT 42" EXTENSION ARM 0=C] S SEE SHEET ES2 NOTE: REFER TO SHEET701' FOR NATIONAL ACCOUNT VENDORS LIST CONDUCTOR SCHEDULE CONDUCTORS / CONDUITS SHALL BE SIZED ACCORDING TO THE FOLLOWING CHART UNLESS OTHERWISE NOTED. CKT BKR WIRE (AWG) EQUIP. GND CONDUIT 15 12 #12 3/4" 20 12 #12 3/4" 30 10 #10 3/4" 40 8 #10 1" 50 6 #10 1" 60 6 #10 1" 70 4 #8 1-1/4" 80 4 #8 1-1/4" 90 3 #8 1-1/4" 100 3 #8 1-1/4" 125 1 #6 1-1/2" 150 #1/0 #6 2" 175 #2/0 #6 2" 200 #3/0 #6 2" 225 #4/0 #4 2-1/2" 250 250KCMIL #4 3" 400 600KCMIL #2 4" NOTES: 1. NEUTRAL CONDUCTOR (IF REQUIRED) SHALL BE THE SAME SIZE AS PHASE CONDUCTORS. 2. ALL HVAC OR OTHER CYCLICAL EQUIPMENT SHALL UTILIZE HACR TYPE CIRCUIT BREAKERS. 3. CONTRACTOR TO PROVIDE QUANTITY OF CONDUCTORS AS NECESSARY TO POWER LOADS. 4. CONDUIT SIZES BASES ON FOUR CONDUCTORS MAXIMUM. CONTRACTOR SHALL FOLLOW NEC GUIDELINES FOR DERATING AMPACITIES AND CONDUIT SIZES FOR ALL COMBINED CIRCUITS. 5. CONDUCTORS SHALL BE COPPER. INDICATED SIZES ARE FOR USE WITH COPPER CONDUCTORS. B. FOR BREAKERS SIZES NOT INDICATED SUCH AS 25A, COMPLY WITH NEC SECTION 240.4 (PROTECTION OF CONDUCTORS.) 7. CONTRACTOR SHALL COORDINATE THE REQUIRED NUMBER OF CONDUCTORS WITH EQUIPMENT MFR PRIOR TO ROUGH IN. I Ln Ln o c00 M_ Ln - M M cC t__ Q bbcNN Ox"'j � kn Oaov~ N o+ ct cl:c�f�Ow PROJECT NO: 20-xxx DRAWN BY: T.OWENS CHK'D BY. G W STEWA SHEET NO: IPANEL SCHEDULES 0 E4 2 t 9 A P I.) u OC--------- 7 OB EMERSON PRE -PROGRAMME[ CONTROLLER "EMS PANEL" MTD. NEXT TO ELECTRICA' PANELS, AS CLOSE A POSSIBLE � 1 .)1 1 � 1 I ( ) ) 1 I A11 /�/�\ItII N#T T11911 rlllr I ATr I,IAeI IAee i DEVICE SCHEDULE SYMB DESCRIPTION CABLE TYPE SUPPLIER INSTALLER NOTES OUTDOOR AIR TEMP BELDEN 8761 OR EQUIVALENT GENERAL OT (501-1122) (22AWG, 2C, STRANDED, SHIELDED) EMS SUPPLIER CONTRACTOR (1) PER RECEIVING ENTRY MOUNTED 8'-0" A.F.F. ST SUPPLY TEMP (201-0041) BELDEN 8761 OR EQUIVALENT EMS SUPPLIER GENERAL (1) PER HVAC UNIT IN SUPPLY DUCT (22AWG, 2C, STRANDED, SHIELDED) CONTRACTOR TOUCHSCREEN GENERAL TS THERMOSTAT (810-1600) 8C T-STAT CABLE EMS SUPPLIER (1) PER HVAC UNIT ZONE 8'-0" A.F.F. CONTRACTOR ® RJ-11/RJ-45 DATA JACK CAT-5 DATA CABLE GENERAL GENERAL (1) AT OFFICE COMPUTER CART PHONE COMBO (24AWG, 4 TWISTED PAIR) CONTRACTOR CONTRACTOR GENERAL GENERAL (1)PER RESTROOM OS MOTION SENSOR SWITCH LEVITON EZ-FIND ODS-10-IDW CONTRACTOR CONTRACTOR (1) PER BREAK ROOM (1) PER OFFICE N ':] (j� EMS LOW VOLTAGE PLAN EMS1 SCALE: 3/16" = 1'-0" PROVIDE AND INSTALL ONE (1) 24GA., 4 TWISTED -PAIR, CAT5 DATA CABLE WITH MODULAR COMBO RJ-11/RJ-45 JACK AT OFFICE. RJ-45 CABLE TO BE RUN FROM JACK, TO REGISTER IN CONDUIT. KEY NOTES (THIS SHEET ONLY) ALWAYS INSTALL THERMOSTATS 8'-0" A.F.F. THE EXACT MOUNTING LOCATION OF THE THERMOSTAT "TS" MAY VARY DEPENDING ON THE STORE LAYOUT AND DUCT CONFIGURATION. REFER TO SITE SPECIFIC MECHANICAL DRAWINGS FOR HVAC ZONED THERMOSTAT MOUNTING LOCATIONS. IF THERMOSTATS ARE MOUNTED ON EXTERIOR WALLS DUE TO DUCT CONFIGURATION, THEY ARE THEN TO BE INSULATED TO PREVENT AIR INFILTRATION. IF ADDITIONAL HVAC UNITS ARE USED, ADD ADDITIONAL THERMOSTATS "TS".. 0 PHONE LINE #1 - TWO RJ-11 PORTS. ONE (1) LOCATED IN OFFICE W/RJ-45 DATA JACK COMBO AND ONE (1) AT REGISTER. 24 GA. CAT 5, 4-PAIR TWISTED WIRE ONLY. USE BLUE AND BLUE & WHITE WIRES. HOOK TO LINE #1 TERMINAL IN RJ-11 JACK EACH PHONE JACK TO HAVE DEDICATED, SEPARATE HOME RUN TO DMARC. LABEL AS "PHONE" AT THE DESTINATION AND AT DMARC. PHONE COMPANY PROVIDES FINAL HOOK UP TO DMARC ONLY.PHONE LINE #2 - RJ-11 PHONE JACK SUPPLIED AND WIRED BY CONTRACTOR. n, a PROJECT NO 20 xxx DRAWN BY T OWENS CHK'DBY G.W.STEWART SHEET NO: LOW VOLTAGE PLAN EMS 1 A� ra t: K SYMBOL LEGEND SANITARY PIPING SAN SANITARY PIPING BELOW V VENT PIPING COLD WATER PIPING CW HW HOT WATER PIPING k SHUT-OFF VALVE PIPE TURNING DOWN -o PIPE TURNING UP JD P-TRAP T WALL CLEANOUT E FREEZE -PROOF HOSE BIBB 2-WAY EXTERIOR CLEANOUT !rs FLOOR CLEANOUT - OCCUPANT LOAD: RETAIL: 7263 SF @ 60 GROSS = 122 STOCK: 1111 SF @ 300 GROSS = 4 BREAK/OFFICE: 175 SF @ 60 GROSS � 4 TOILET/HALL: 175 SF @ 60 GROSS = 4 COUNTER /� i H 1/2" CW SUPPLY - 1/2" HW SUPPLY 1 1/4" O.D. TAILFACE 1 1/4" O.D. WASTE FINISHED FLOOR TEMP. LIMITING DEVICE DETAIL P2 TEMPERED WATER SLOAN MODEL 110-AF 1/2" THERMOSTATIC TEMPERING VALVE 3/4"DCW EWH-2 SHALL BE SUSPENDED FROM CEILING 7'-6" A.F.F. USING 3/8" EWH-2 ALL THREAD AND UNISTRUT. FURNISH MS-1 WITH DRAIN PAN. DRAIN PIPING ROUTED TO MOP SINK BELOW. 3 U 0 REFER TO PLUMBING PLAN SHEET P1 FOR CMONTINUATION. lJ V REFER TO PLUMBING PLAN SHEET P1 FOR CONTINUATION. DOMESTIC COLD WATER ROUTED UP FROM BELOW SLAB N REFER TO PLUMBING PLAN SHEET P1 FOR CONTINUATION. i I i 1 "DCW ,.��WHERE DOMESTIC WATER PIPING PENETRATES FIRE RATED WALL INSTALL THRU WALL FIRE RATED /4"DHW ASSEMBLY. SEE DETAIL 3/P2. I WHERE VENT PIPING WCO-1 PENETRATES STOCKROOM 1. SIDE OF FIRE RATED %4DCW WALL INSTALL THRU WALL FIRE RATED ASSEMBLY. SEE DETAIL 3/P2. KEY NOTES (THIS SHEET ONLY) 1" DOMESTIC WATER SERVICE AND METER. WATER LINE SHALL ENTER BUILDING UNDER SLAB AND ROUTED ON ENLARGED PLUMBING PLANLUMBING PLAN WARM SIDE OF INSULATED FURRED WALL. SEE CIVIL DRAWINGS FOR CONTINUATION. P2 SCALE: 112" - 1'-0" 2� 4" SANITARY SEWER WITH 1/8" FALL. SEE CIVIL DRAWINGS FOR CONTINUATION. PROVIDE 2-WAY EXTERIOR CLEANOUT (ECO-1) WITHIN 5'-0" OF BUILDING. SEE SHEET P1 FOR CONTINUATION. 1 "CW 2 P3 REFER TO PLUMBING PLAN SHEET P1 FOR CONTINUATION. WC-1 - 4"SAN U N a cf) SHUT-OFF VALVE (TYP.) d- ACCESS PANEL FURNISHED BY PLUMBER. LAV-1 4"SAN - 4"SAN WC-1 PLUMBING FIXURE SCHEDULE MARK DESCRIPTION HW CONNECTION CW CONNECTION ASTE CONNECTION VENT CONNECTION REMARKS 20"X18" WALL HUNG ADA LAVATORY WI FRONT OVERFLOW, CONCEALED HANGERS & 4" CENTERS. AMERICAN STANDARD LUCERNE #0355.012 OR EQUAL. FAUCET SHALL B LAV-1 ADA LAVATORY 1/2" 1/2" 2" 1-1/2" POLISHED CHROME -PLATED CAST BRASS BODY WITH 4" SPOUT, 4" BRASS WRIST BLADE, 0.5 GPM SPRAY & POP-UP DRAIN. AMERICAN STANDARD MONTERREY #5501.170 WITH #V05 AERATOR OR EQUAL. INSULATE EXPOSED DRAIN & WATER PIPES WITH TRUEBRO LAV GUARD KIT #102 E-Z. PROVIDE SUPPLY LINES, STOP VALVES & P-TRAP. FLOOR MOUNTED ADA VITREOUS CHINA ELONGATED 1.6 FLUSH GALLON CLOSE COUPLED TWO PIECE SIPHON JET WATER CLOSET & FLUSH TANK WITH 12" ROUGH -IN, WC-1 ADA WATER CLOSET 1/2" 4" 2" AMERICAN STANDARD CHAMPION 4 "RIGHT HEIGHT" #2002.014 OR EQUAL. PROVIDE STOP VALVE, FLEXIBLE SUPPLY LINE & OPEN FRONT SEAT (AMERICAN STANDARD TRIP LEVER ON APPROACH SIDE #5901.100 OR EQUAL). PROVIDE 10 GALLON ELECTRIC WATER HEATER,1.65KW @ 120V WITH MANUFACTURER SUPPLIED TEMPERATE AND PRESSURE RELIEF VALVE. (A.O. SMITH #EJC-10, OR EQUAL). SET WATER HEATER TEMPERATURE AT 110°F MAXIMUM. LAVATORIES SHALL BE EQUIPPED WITH INDIVIDUAL TEMPERATURE LIMITING DEVICES THAT CONFORM WITH ASSE 1070. ELECTRIC WATER HEATER PROVIDE THERMAL EXPANSION TANK. (AMTROL THERM-X-TROL ST-12, OR EQUAL). EWH-1 W/TEMP LIMITING DEVICE 3/4" 3/4" EXPANSION TANK SUPPORT: SET @ 110°F PROVIDE ADEQUATE SUPPORT FOR THE EXPANSION TANK. SUPPORT TO ADJACENT WALL OR FROM EXISTING STRUCTURE ABOVE WITH UNISTRUT. DO NOT SUPPORT FROM PIPE ALONE. PROVIDE DRAIN PAN UNDER WATER HEATER. PROVIDE SEISMIC STRAPPING ON WATER HEATER. TERMINATE (EWH-1) DRAIN LINE TO EXTERIOR. PROVIDE FULL SIZE T&P RELIEF LINE. REFER TO WATER HEATER DETAIL ON SHEET P3 FOR ADDITIONAL INFORMATION. PROVIDE 10 GALLON ELECTRIC WATER HEATER, 1.65KW @ 120V WITH MANUFACTURER SUPPLIED TEMPERATE AND PRESSURE RELIEF VALVE. (A.O. SMITH #EJC-10, OR EQUAL). SET WATER HEATER TEMPERATURE AT 140°F MAXIMUM. PROVIDE THERMAL EXPANSION TANK. (AMTROL THERM-X-TROL ST-12, OR EQUAL). EWH-2 ELECTRIC WATER HEATER 3/4" 3/4" EXPANSION TANK SUPPORT: SET @ 140°F PROVIDE ADEQUATE SUPPORT FOR THE EXPANSION TANK. SUPPORT TO ADJACENT WALL OR FROM EXISTING STRUCTURE ABOVE WITH UNISTRUT. DO NOT SUPPORT FROM PIPE ALONE. PROVIDE DRAIN PAN UNDER WATER HEATER. PROVIDE SEISMIC STRAPPING ON WATER HEATER. TERMINATE (EWH-2) DRAIN LINE IN MOP SINK (MS-1). PROVIDE FULL SIZE T&P RELIEF LINE. REFER TO WATER HEATER DETAIL ON SHEET P3 FOR ADDITIONAL INFORMATION. 24" X 24" MOLDED STONE MOP SERVICE BASIN, WITH T DRAIN. FIAT #MSB•2424 OR EQUAL. PROVIDE SERVICE FAUCET WITH PAIL HOOK & INTEGRAL VACUUM BREAKER, MS-1 MOP SINK 3/4" 314" 3" 2" MOP BRACKET, FLAT STAINLESS STEEL STRAINER AND HOSE & BRACKET. FIAT #830 AA, 889 CC,1453 BB & 832 AA OR EQUAL. PROVIDE SUPPLY LINES AND P-TRAP. BARRIER FREE ELECTRIC DRINKING TWO -STATION, WALL MOUNTED, ELECTRIC DRINKING FOUNTAIN, BARRIER -FREE ACCESS (ADA), FRONT ONLY EASY TOUCH CONTROL, HIGH UNIT ON RIGHT. EDF-1 FOUNTAIN 112" 2" 1-1/2" ELKAY #EZTLRDDC OR EQUAL. PROVIDE SUPPLY LINE, STOP VALVE & P-TRAP. PROVIDE CANE APRON AS REQUIRED. FREEZE -PROOF WALL HYDRANT WITH BRONZE BODY & ANTI -SIPHON VACUUM BREAKER, BOX AND LOCKING COVER. PROVIDE WITH HOSE CONNECTION AND MOUNT AT 24" WHA WALL HYDRANT 314" ABOVE GRADE. WOODFORD #365 OR EQUAL. WCO.1 WALL CLEAN -OUT - AS SHOWN ON SIZE & INSTALL AS SHOWN ON PLANS. JOSAM, ZURN OR EQUAL. PLANS ECO.1 EXTERIOR CLEAN -OUT 4" PROVIDE TRAFFIC RATED, 2-WAY, EXTERIOR CLEANOUT. TYLER PIPE #003519, OR EQUAL. AS SHOWN ON PROVIDE ADJUSTABLE FLOOR CLEANOUT WITH WATERTIGHT TAPERED THREADED PLUG AND ROUND SCORIATED SECURED TOP, ADJUSTABLE FD-1 FLOOR DRAIN AS SPHIOIWSN ON SIZE & INSTALL AS SHOWN ON PLANS. JOSAM, ZURN OR EQUAL. "SAN WCO-1 3/4 I'm REFER TO PLUMBING -V!C-yµPLAN SHEET P1 FOR WH-1 CONTINUATION. 1 /2"HW 3/4"HW -�� 1 /2"CW -h WCO 1 II N 2 ENLARGED PLUMBING PLAN P2 SCALE: 1 /2" = V-0" MATERIALS 1. DRAIN, WASTE AND VENT A. SCHEDULE 40 AND 80 PVC OR ABS PIPING WITH DWV PATTERN FITTINGS TO BE USED UNLESS OTHERWISE REQUIRED BY LOCAL CODE. 2. HOT AND COLD WATER A. ABOVE GRADE. a) TYPE "L" COPPER TUBING, HARD TEMPER, COLD DRAWN WITH WROUGHT COPPER LEAD FREE SWEAT FITTINGS. CONNECTIONS TO FIXTURES AND EQUIPMENT SHALL BE MADE WITH 85% RED BRASS IPS SIZE PIPE OR COMPRESSION ANGLE STOPS. PROVIDE DIELECTRIC UNIONS WHERE CONNECTING PIPING OF DISSIMILAR MATERIALS. B. BELOW GRADE. b)TYPE "K" COPPER TUBING, HARD OR SOFT TEMPER, WITH WROUGHT COPPER LEAD FREE SWEAT FITTINGS. NOTE: NO FITTINGS SHALL BE PERMITTED BELOW GRADE INSIDE BUILDING. 3. AIR CONDITIONING CONDENSATE A. SEE MATERIALS, SECTION 1, UNLESS OTHERWISE REQUIRED BY CODE. 4. NATURAL GAS PIPING A. SCHEDULE 40, ASTM A120, BLACK IRON PIPE WITH 150 LB. BLACK MALLEABLE THREADED OR SOCKET WELDED FITTINGS. PLUMBING SPECIFICATIONS: 1. CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR AND MATERIALS REQUIRED FOR A COMPLETE AND OPERATIONAL SYSTEM IN ACCORDANCE WITH THE 2017 FBC AND ALL OTHER APPLICABLE CODES. CONTRACTOR SHALL PAY ALL FEES AND PERMITS REQUIRED. 2. CONTRACTOR SHALL GUARANTEE INSTALLATION AGAINST DEFECTS IN WORKMANSHIP, EQUIPMENT, AND MATERIAL FURNISHED ON PROJECT FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE. PROVIDE EXTENDED GUARANTEES FOR EQUIPMENT SUCH AS WATER HEATERS WHEN REQUIRED. 3. SUBMIT FOR APPROVAL THE NUMBER OF SHOP DRAWINGS AND MANUFACTURER'S LITERATURE ON ALL PLUMBING FIXTURES AND MATERIALS AS REQUIRED TO THE ARCHITECT OR OWNER'S REPRESENTATIVE 4. CONTRACTOR SHALL VISIT THE JOB SITE AND EXAMINE PREMISES AT THE ADJACENT TO PROPOSED WORK. VERIFY EXISTING PIPE SIZES, LOCATION, AND SUITABILITY FOR CONNECTION TO THE NEW SYSTEM PRIOR TO BID. 5. DRAWINGS ARE DIAGRAMMATICAL AND INTEND TO SHOW APPROXIMATE LOCATION OF PIPING, FIXTURES, ETC. CONTRACTOR SHALL REVIEW ALL ARCHITECTURAL, CIVIL, STRUCTURAL, ELECTRICAL, AND MECHANICAL DRAWINGS AND COORDINATE WITH OTHER TRADES FOR PIPE ROUTING AND EQUIPMENT PLACEMENT. INSTALL ALL WORK WITHOUT CONFLICT WITH OTHER TRADES AND MAKE MINOR ALTERATIONS AS REQUIRED WITHOUT ADDITIONAL COST TO OWNER. 6. CONTRACTOR SHALL COOPERATE FULLY WITH THE OWNER IN SCHEDULING AND MAKING CONNECTIONS TO EXISTING SERVICE LINES SO AS TO CAUSE THE LEAST POSSIBLE INCONVENIENCE AND SHORTEST POSSIBLE INTERRUPTION OF SERVICE. 7. CONTRACTOR SHALL COORDINATE WITH ELECTRICAL CONTRACTOR ALL VOLTAGES, ELECTRICAL LOADS, ETC., OF ELECTRICALLY OPERATED EQUIPMENT PRIOR TO PURCHASING EQUIPMENT. ALL EQUIPMENT SHALL BE U.L. AND NEMA APPROVED. 8. MAINTAIN A MINIMUM CLEARANCE OF 3'-0" IN FRONT OF ALL ELECTRICAL PANELS AND 1'-0" EITHER SIDE OF PANEL TO STRUCTURE. ALL PIPING SHALL BE ROUTED AROUND THIS- AREA. 9. CONTRACTOR SHALL FURNISH ACCESS PANELS, TO BE INSTALLED BY THE GENERAL CONTRACTOR, AS REQUIRED FOR PLUMBING INSTALLATIONS. 10. ALL SANITARY VENT PENETRATIONS SHALL BE A MINIMUM DISTANCE OF 10'-0" AWAY FROM ALL ROOFTOP MECHANICAL EQUIPMENT OR OTHER AIR INTAKE RELATED DEVICES, 11. ALL HORIZONTAL AND VERTICAL PIPING SHALL BE SUPPORTED IN ACCORDANCE WITH STATE AND LOCAL REQUIREMENTS. SUPPORTS SHALL SECURELY HOLD PIPING, PREVENT VIBRATION, COMPENSATE FOR STATIC AND OPERATIONAL CONDITIONS OF THE VARIOUS SYSTEMS, AND SHALL NOT BE SUBJECT TO ELECTROLYTIC ACTION. 12. CONTRACTOR TO COORDINATE AND INSTALL, IF REQUIRED FOR THIS PROJECT, NEW WATER METER AS PER REQUIREMENTS OF LOCAL UTILITY COMPANY. CONTRACTOR SHALL INCLUDE ALL TAP FEES AND COST INTO BID FOR A COMPLETE INSTALLATION. 13. WATER PIPING PASSING THROUGH OR UNDER FOOTINGS OR FOUNDATION WALLS SHALL BE SLEEVED OR OTHERWISE PROTECTED. 14. VALVES SERVING DOMESTIC WATER SYSTEMS SHALL BE BALL VALVES OR APPROVED EQUALS. ALL VALVES SHALL BE LOCATED SO AS TO BE ACCESSIBLE BY MAINTENANCE PERSONAL. 15. PROVIDE 1" THICK FIBERGLASS PIPE INSULATION WITH SERVICE JACKET ON ALL DOMESTIC WATER PIPING. DOMESTIC COLD WATER PIPE INSULATION SHALL HAVE A CONTINUOUS VAPOR BARRIER. 16. ALL WATER PIPING SHOWN ROUTED IN EXTERIOR WALLS SHALL BE LOCATED INSIDE THE BUILDING INSULATION AND FINISHED WALL TO PREVENT FREEZE DAMAGE. 17. CONTRACTOR SHALL FIELD VERIFY THE LOCATION AND INVERT AT THE POINT OF CONNECTION TO THE SEWER SYSTEM BEFORE DETERMINING FINAL ROUTING OF COIL, WASTE, AND VENT PIPING. 18. ALL SOIL, WASTE, AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON OR SCHEDULE 40 PVC DWV PLASTIC PIPE WHERE ALLOWED BY LOCAL AUTHORITY HAVING JURISDICTION FOR THIS INSTALLATION. PROVIDE 3M FIRE BARRIER CAULK CP-25 CAULKING, OR U.L. APPROVED EQUAL, AT ANY PENETRATION OF FIRE RATED ASSEMBLIES. NOTE, FOAM CORE SCHEDULE 40 PVC IS NOT ACCEPTED. 19. ALL SOIL, WASTE, AND VENT PIPING SHALL BE UNIFORMLY GRADED AND SHALL HAVE A SLOPE OF NOT LESS THAN 1/4" PER FOOT FOR PIPING 3" IN DIAMETER AND SMALLER THAN 1/8" PER FOOT FOR PIPE 4" IN DIAMETER. 20. WATER LINES SHALL PASS INSPECTION OF (4) HOURS UNDER 150 PSI PRESSURE BEFORE ANY USE OF SYSTEM IS MADE FOR DOMESTIC PURPOSES. IT SHALL BE DISINFECTED BY SLOWLY FILLING WITH WATER TO WHICH A DISINFECTING AGENT HAS BEEN INJECTED AT A RATE OF 50 P.P.M. OF CHLORINE, WHICH SHOULD BE ALLOWED TO STAND IN THE PIPING FOR A PERIOD OF 24 HOURS, AFTER WHICH TESTS FOR RESIDUAL CHLORINE SHALL SHOW NOT LESS THAT 5 P.P.M. OF RESIDUAL CHLORINE AT EVERY WATER OUTLET IN BUILDING. IF THE RESIDUAL IS LESS THAN 5 P.P.M. THE DISINFECTION SHALL BE REPEATED UNTIL THE R RESIDUAL IS OBTAINED AT E REQUIRED RE VERY OUTLET. AFTER REQUIRED RESIDUAL IS OBTAINED, THE SYSTEM SHALL BE FLUSHED UNTIL THE CHLORINE LEVEL AT EVERY OUTLET IS REDUCED TO THAT OF INCOMING WATER SUPPLY. FIRE -RATED WALL 20 GA. SPLIT WALL SLEEVE PROSEAL PLUG ����cScccc�u �. c?cQc?c�c�cA�2 c2c�c�2c��{c2`cc)2�'s} c �cc4c <c�.,?cx�icgcc cticc� F cc�hI 1co.,F-�cc ,6 PLUMBING PIPING FIREFILL CERAMIC `' 20 GA. STEEL FIBER FIRESTOP PLATE - NOTE: FIRE -RATING OF DEVICE SHALL BE EQUIVALENT TO OR GREATER THAN THE RATING OF THE ASSEMBLY PENETRATED. PLUMBING THRU FIRE RATED WALL DETAIL SCALE: NONE , z0da �O K M C� CC "' cat- cd ox�.. =tn N U P,NW110 [-+ U € R C bqQ �/1 C � C a Dit tv �I� I 0 o z w > Q Rio dui ry Ca � 00 ti C O a � o, W °C Z p W V ~ K Q c r. C PROJECT NO: 20-xxx DRAWN BY: T.OWED CHK'D BY: G.W. STE SHEET NO: ENLARGE] Ni PLUMBIN( PLAN P2 0 EXTRA HEAVY DUTY CAST IRON BRONZE TAPER THREAD ADJUSTABLE SCORIATED PLUG WITH COUNTER SECURED COVER SUNK HEAD FLUSH WITH GRADE LINE - — 2, 1 n L FLANGE WASTE LINE LENGTH TO SUIT 4„ q„ FLOW ® FLOW NOTE: ECO-1 SHALL BE INSTALLED WITHIN 5'-0" OF THE BUILDING EXTERIOR. 2-WAY CLEAN -OUT DETAIL P3 SCALE: N.T.S. CLEAN -OUT PLUG AS SPECIFIED. APPLY TEFLON JOINT COMPOUND TO THE CLEAN UT PLUG READS. FLOOR SLAB ON GRADE SAME SIZE AS DRAIN LINE MEMBRANE CLAMP AS REQUIRED FOR LONG SWEEP ELBOW DEPTH OF SEWER AT END, OR TURN OF RUN. SANITARY AND/OR STORM SEWER, SIZE PER PLAN COMBINATION WYE AND EIGHTH BEND IN RUN. REDUCING TYPE IF REQUIRED. ENTER TOP OF PIPE. ® FLOW NOTE: REFER TO SCHEDULE FOR ADDITIONAL INFORMATION. LOCATE AT ENDS OF RUNS. TURNS OF PIPE GREATER THAN 45°, 50' INTERVALS ON STRAIGHT RUNS, AND/OR WHERE SHOWN ON PLANS & RISERS. PROVIDE BACKFILL AS REQUIRED. LOCATE CLEAN -OUT WHERE THERE IS 18" CLEAR AROUND, FOR ACCESSIBILITY, COORDINATE WITH LOCAL CODES AND AUTHORITY HAVING JURISDICTION FOR ANY ADDITIONAL REQUIREMENTS. PROVIDE FLOOR CLEAN -OUT WITH ADJUSTABLE COVER. CLEAN -OUT COVER SHALL BE SUITABLE FOR RESPECTIVE FLOOR COVERING (RECESSED FOR TILE, SCORIATED FOR UNFINISHED FLOORS, ETC.). CLEAN THE TOP OF EXPOSED FLOOR CLEAN -OUT AFTER INSTALLATION. 4 FLOOR CLEAN -OUT DETAIL P3 SCALE: N.T.S. METAL SHUT-OFF VALVE 3/4" CW INLET -- 3/4" HW OUTLET - 3/8" GALVANIZED ALL THREAD VACUUM BREAKER DIELECTRIC UNION SHUT-OFF VALVE - THERMAL EXPANSION TANK. SIZE AND INSTALL PER MANUFACTURER'S RECOMMENDATIONS. DO NOT SUPPORT BY PIPING. WATTS #100XL T&P (EWH-1) RELIEF VALVE WATER HEATER SHALL BE DIELECTRIC INLET SUSPENDED FROM CEILING ABOVE HEATTRAP MOP SINK (MS-1) ON HOLDRITE DISCHARGE LINE FULL T #f3R /IAI�M�IFK6SB9RM1 SIZE OF VALVE, TO Ii�b$4NEQ)RW` 4EVM 4)VTHREAD MOP SINK (MS-1) SIN& �AW11)RUT. COORDINATE WITH SUPPORT FRAMING GENERAL WATER HEATER DRAIN CONTRACTOR. EWH-1 SHALL BE HOLDRITE MODEL# QP INSTALLED AT 7'-6" A.F.F. OR EQUAL DRAIN PAN, SIZE PER 1 DRAIN LINE. ROUTE TO MOP SINK MANUFACTURERS RECOMMENDATIONS. (MS-1). MOP BRACKET. INSTALL SO MOPS ALWAYS DRIP INTO MOP SINK. SERVICE FAUCET FLOOR HOSE/HOSE BRACKET MOP SINK (MS-1) EWH-1 DETAIL P3 SCALE: N.T.S. 7 MOP SINK DETAIL P3 SCALE: NONE VENT VENT 45' MIN. SOIL OR WASTE SEWER CONNECT VENT TO SOIL OR SOIL OR WASTE PIPING ABOVE WASTE CENTERLINE. UNDER SLABCD SEWER HORIZONTAL CONNECTIONS OF VENT PIPING TO WASTE SEWER SYSTEM PIPELINE SHALL NOT BE J"�T ALLOWED. 5 VENT PIPE INSTALLATION DETAIL P3 SCALE: N.T.S. LH OOK BREAKER 4" SEWER SERVICE. PROVIDE 2 WAY — EXTERIOR CLEAN -OUT (ECO-1), WITHIN 5-0" OF BUILDING EXTERIOR. SEE CIVIL DRAWINGS FC CONTINUATION. 4" VENT THRU WALL PLUMBING CONTRACTOR SHALL FURNISH METAL VENT COVER FOR ALL "VENT THRU WALLS" �1"C 1 "CW 111CW 3/4" ?HW 3/4"CW EWH-2 3/4"HW 3/4"CW MS-1 0 ct kr)ct cQ : Q N 42"V2J LAV-1 3^ 3" h=�1 2"V FCO-1 SANITARY SEWER NOTES, WC-2 1. EWH-1 TO DRAIN INTO HUB DRAIN (HD-1). 2. EWH-2 TO DRAIN INTO MOP SINK (MS-1). SANITARY SEWER RISER P3 SCALE: N.T.S. SHUT-OFF VALVE (TYP.) 3/4"CW- 1/2"HW 3/4"CW I I I 3/4"H W 1/2"CW EWH-1 3/4"CW � 1/2°'C 1"CW �� 3/4"CW 1 "C W EDF-1 1 /2"CW CW 1 CW 111CW 1/2"CW � HD-1 SHUT-OFF VALVE (TYP.) 1 /2"C W TP-1 "CW 3/4"C W WH-1 6 DOMESTIC WATER RISER P3 SCALE: N.T.S. 1 I I I oi� 1" DOMESTIC WATER SERVICE AND METER. y WATER LINE SHALL BE ROUTED ON WARM SIDE a a_ -sue OF INSULATED FURRED WALL. SEE CIVIL w N DRAWINGS FOR CONTINUATION. ¢ �' a 3/4"C W I�' rT1 WH 11 a 1/2"CW 1/2"HW Q1 a z r la LAV-1 hn WC-2 w 0 w PROJECT NO: 2 DRAWN BY: T 1 CHK'D BY: G. SHEET PLUMI DETA & RI5 IQ